Loading...
HomeMy WebLinkAbout2005 - Remove/Replace Chimney Town of Montville Building Department Field Inspection Notice Address: 23 Bayberry Ln. Job Description: Chimney - remove & replace Permit Numbers: B2005-0015 Footing Not Approved: Approved: Comments: 1 Deck Piers Not Approved: Approved: Comments: t- Backfill Not Approved: Approved: Comments: i- Anchor Bolts Not Approved: Approved: Comments: 1 Concrete Slab Not Approved: Approved: Comments: 1. Rough Plumbing Not Approved: Approved: Comments: 1 Rough HVAC Not Approved: Approved: Comments: 1 Rough Electric Not Approved: Approved: Comments: 1 Pool Bonding Not Approved: Approved: Comments: 1. Electrical Trench Not Approved: Approved: Comments: I Electrical Service Not Approved: Approved: Comments: 1 Gas Line Not Approved: Approved: Comments: i Masonry Fireplace Not Approved: Approved: Throat & Chimney Comments: i FireBlocking & Not Approved: Approved: 2/4/05 JS Draftstopping Comments: 1 Framing Not Approved: Approved: Comments: 1 Insulation Not Approved: Approved: Comments: 1• Certificate of Not Approved: Approved: Occupancy Comments: i Comments: 1. Chimney Final, approved 2/22/05 JS Pagel of l Revised 9/20/04 TOWN OFMONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: 62005-0015 Date: 13-Jan-05 Map/Lot: 030/050-000 Owner ID: 138000 Project Location: 23 BAYBERRY LANE Unit: Sob Description: remove & replace chimney Owner Name: Thomas K and Carol E Howard Tenant Name: N/A Careof: 23 Bayberry Lane Uncasville CT 06382- Telephone: Contractor Name: Chimney Jim-ney Telephone: (203)445-7749 DBA: Lic/Reg Type: HIC Lic/Reg No: 520776 50 Harborview Terrace Exp Date: 30-Nov-05 Stonington Ct 06378- Construction Value Permit Fees Construction Information Building Value: $11,200.00 Building Fee: $96.00 Use Group: R-4 Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 1999 State Building Code w/2004 Amendment Mechanical Value: $0.00 Mechanical Fee: $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: 5B Total Value: $11,200.00 Penalty Fee: $0.00 Permit Code: R4 C of 0 Fee: $0.00 Comments: Plan Review Fee: $0.00 State Ed Fee: $1.79 Total Fee: $97.79 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIQNS PLUMBING MECHANICAL ELECTRICAL PERMIT INSPECTIONS ❑ Footing - Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill - Footing drains and waterproofing ❑ Elec Trench - with conduit installed ❑ Concrete Slab - Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts - with sill plate and prior to floor framing ❑ Electrical Service CRS No: 0 ❑ Framing ❑ R HVAC ❑d Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking _Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation 0 Certificate o pproval if of Occupancy Building Official's Approval: Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax. 848-7231 Residential Building Permit Application Form Permit ov 1,6- F] New Construction E] Addition alteration F~ Accessory Structure Single Family Two-Tamily F-1 Townhouse Job Address ~ 3 /!>69 bw (Number) -y~ (Street) (Unit) Job Description'! Mailing Address 03 Owne ~AYeoye y City utycOYS V/t-(-6 State C7-Zip 030 Tel Contractor 110A119'- alPAlfy Mailing Address -5?) City State___L- Zip O~ 379 Tel ®203 l YK5- l 77" Contractor's License/Registration Type & Number D 77 Exp. Date _/3c) l ~ I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Separate applications are required or electrical, plumbing, mechanical, etc. Owner /Agent Signature Date~_/ /r Construction Value Fee Building $ 41, a o $ Plumbing $ $ Mechanical $ $ Electrical $ $ Certificate of Occupancy $ Plan Review Fee $ State Education $ Penalty Fee $ ' - Total $ $ - (See Reverse side for additional requirements) 9Z isedXbvember1, 2004 Town of Montville Building Department Receipt No. t b = Date From: L Job Address: Check # Cash Check Amount $ (circle one) f Percrut # ..r Received y Permit Fee Calculation Spreadsheet MISCELLANEOUS PERMIT CALCULATION Address: Pools & Spas Above Ground Round EA $ 3,200.00 $ Above Ground Oval EA $ 6,000.00 $ In-Ground EA $ 20,700.00 $ - Heater EA $ 3,465.00 $ Hot Tub EA $ 5,250.00 $ Roofing Strip & Reroof SQ $ 275.00 $ Overlay SQ $ 185.00 $ Plywood SQ $ 105.00 $ Plumbing Full Bath EA $ 4,230.00 $ Half Bath EA $ 2,690.00 $ - Garages Attached, 1 car EA $ 8,885.00 $ Attached, 2 car EA $ 15,114.00 $ - Attached, 3 car EA $ 20,914.00 $ Detached, 1 car EA $ 11,657.00 $ - Detached, 2 car EA $ 17,456.00 $ Detached, 3 car EA $ 23,256.00 $ - Sheds SF $ 26.25 $ - Sheds with Electrical SF $ 26.25 $ Electrical Service 100 Amp EA $ 825.00 $ 200 Amp EA $ 1,500.00 $ Siding SQ $ 600.00 $ - Windows EA $ 445.00 $ Doors EA $ 625.00 $ - Decks/Porches/Sunrooms Open SF $ 22.31 $ Covered SF $ 62.69 $ Enclosed SF $ 123.90 $ TOTAL BUILDING CONSTRUCTION COST $ PERMIT FEE CALCULATIONS Fee Building $ 11,200 $ 96.00 Plumbing $ - $ _ Mechanical $ $ Electrical $ - $ Work Commenced before permit issuance $ CO Fee $ Plan Review $ _ State Ed Fee $ 11,200 1.79 Total Fees $ 97.79 Based on 2003 RS Means Residential Cost Data 1/7/05 Forever Flex0"t is the ultimate solution for the problems that plague most chimneys. A properly lined chimney is able to function correctJy with today's heating appliances and improves the safety of your home. Sleep Easy Fore>verFlex'r" -chimney liner is air and water tight. It locks in moisture and flue gases in your chimney and keeps them out of your home! Forever Flek'O is made from 316Ti or AL29-4G stainless steel. These unique alloys are designed specifically to resist acids in the flue and extreme stresses of hot and cold cycles. The Forever Fle)ff liner has been U! tested under the most extreme conditions including multiple simulated chimney fires exceeding 2100° F. You'll sleep soundly at night knowing that your home is safer for yourself and your family. The Forever Warranty Forever Flek" offers the state-of-the-art venting solution for your home, The air and water tight chimney lining is the highest quality available on the market today. And Forever FlexIm can offer what no one else does. An industry exclusive Forever WarraRtyTM i That's right, forever! That means that even if you sell your home, this same forever Warrai?Wy can be passed on to the new homeowner, and this increases the value of your property. Let's get your chimney problems resolved with the very best solution -The Forever Solution. ,CAI'/UIIY DUSTED • d t ir6S66SO98 SMJOM ROuw t yO 481 : eo so LO Uer c Town of Montville 310 Norwich-New London Tpke. Uncasville, Ct. 06382 Building Department 860-848-3030-Ext.3 82 January 6, 2005 Thomas & Carol Howard 23 Bayberry Lane Uncasville, Ct. 06382 Re; 23 Bayberry Lane, Uncasville On January 5, 2005 the Town of Montville fire inspector requested that I conduct an inspection of the damage caused by a chimney fire at the above referenced address. During the inspection I noted the following: 1) The wood stove in the basement is vented through an unsafe, non-code compliant chimney. This chimney is constructed such that is utilizes the fireplace chimney as part of its length. It is improperly connected to, the fireplace chimney at the damper allowing creosote to build-up outside the flue, subsequently causing the fire. The fireplace firebox and unsafe chimney connector have been removed by the Fire Department in their effort to put out the fire. Before the fireplace chimney can be reused the fireplace firebox and smoke chamber must be repaired and the chimney must be inspected, and deemed safe, by a licensed chimney professional, and a written report of said inspection must be presented to the Building Department. 2) The furnace flue constructed in the same chimney enclosure as the fireplace flue is cracked in the area of the fireplace firebox. Because this crack will allow chimney gases to be vented directly into the structure I have ordered the furnace secured until the entire length of the furnace flue piping is inspected by a licensed chimney professional and repaired to make it safe. A written report of this inspection must be presented to the Building Department. 3) The fire damages electrical wiring passing through the area above the fireplace lintel. I have order the breaker for the circuit controlling the wiring to be secured and the circuit cannot be re-energized until the unsafe wiring is removed from the circuit. When this wiring is replaced, it cannot pass through the area above the fireplace lintel. Please be advised that permits are required for all the necessary repairs. If you have any questions you may contact me at the Town of Montville Building Department during regular working hours. 7ernon D. Vesey II Building Inspector Cc: Fire Marshal File _ y 7 w L s"c .~i D~ilHA ` Chimney Fire 23 Bayberry Lane January 5, 2005 ~~i'®• x _yy~ `yam { IA' 'K t0o t ~ ` ,f. h s`+."~"w..-~~ _ y~ ~ •.i ate'" v f r - J- k ir'.a.,.~,~+Q ~yF If,IL`~ i •.r _ . _ + _ ~ ' xs'. . .,i~'t'K'~"++' +'~t4 Y ~ ~ Irv, Y P 1' f ~ 7y~ Y