HomeMy WebLinkAboutSFR - Heating/AC
Town of Montville
BUILDING DEPARTMENT
310 Norwich-New London Turnpike
Uncasville, CT 06382
(860) 848-3030, Ext. 382
Mechanical Permit
Permit Number: M2003-0179 Date: 02-Oct-03 Map/Lot: 131/041-000 Owner ID 2511
Job Location: 24 -AUDELSEN-LANE Unit
Job Description: Heating & Air Conditioning
Owner: Contractor:
Hartens Pond LLC Viglione Heating & Cooling
259 Commerce Street
183 Quarry Road East Haven Ct. 06512-
Milford CT 06460 Telephone: (203) 467-8388
Lic/Reg Type/No.-Si 302380 Exp Date: 31-Aug-04
Tenant:
Self
Telephone:
Construction Values Permit Fees Construction Information
Building Value: $0.00 Building Fee: $0.00 Use Group: R4
Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 1995 CABO
Mechanical Value: $0.00 Mechanical Fee: $0.00 Construction Type: 5B
Electrical Value: $0.00 Electrical Fee: $0.00 Permit Code: R5
Other Value: $0.00 Other Fee: $0.00 Comments:
Total Value: $0.00 CO Fee: $0.00 Included on Building Permit
Plan Review Fee: $0.00
State Ed Fee: $0.00
Total Fees: $0.00
It is the owners responsibility to schedule the following inspections (minimum 48 hours notice reauired):
❑ Footing - Prior to pouring concrete Wl Rough HVAC
❑ Backfill - Footing drains and waterproofing ❑ Fireplace Throat
❑ Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble
❑ Rough Framing ❑ Firestopping/draftstopping
❑ Rough Electrical ❑ Insulation
❑ Electrical Service ❑ Final Inspection
❑ Rough plumbing and leak test ❑ Certificate of Occupany
❑ Gas piping and test
Building Official's Signature:
04/02:/02 01:24; FAX 84872 BUILDING DEPT ! ~e IM01
TowmofMontvdle.
Building Department Perttrit # ~ ~
310 Norwich New LondomTpke.
Tel. 848-7166, Ext 82 UncasvU* Cr 46382 Fax. 848-7231
One & Two.Family Trades Permit Application Form
❑4~1 a rjEacwical ffNe L
11
-Gas OPi?W
Job Description/Wfaterials ®i 1 W a cm C r hea b nc~ cc' J
Owner W~ ` (C P~•~ LLC Mailing Address -Venue,
city ,ef l State Zip C):;Zf Tel 40 J l9l CPOOG
Contractor-VQ ~0 ReCb I -rGlir0\MailingAddress CON MerGe, S+(e
J
City State C'( Zip Tel c 46-7 ! e3 Contractor's. LicenselRegstrationType &Numb er~~~~ cS Exp. Date-3 C J,
T
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the
state of Connecticut- and the Town of Montville and further attest that the proposed work is authorized by the owner in fee
and that I am authorized to make application for a permit for such work as descnbed above.
Date/ l
Owner /Agent Signafiueo..J
Construction Value Fee
$
Building $
$
Plumbing $
Mechanical S
Electrical S $
Other $ $
Certificate of Occupancy $
Plan Review Fee $
State Education $
Total $ $
STATE OF CONNECTICUT + DEPARTMENT OF CONSUMER PROTECTION.
Be it known that
STEPHEN J VIGLIONE SR.
259 CON 4ERCE ST
EAST HAVEN, CT 06512
has been certified by the. Department of Consumer Protection as a licensed
HEATING, PIPING & COOLING UNLEWITED CONTRACTOR
TYPE::S1
License # 3023`80
Effective: 09/0112003
Expires: 08/31
2004. Jam s T. Fleming; Commissioner
i
RWAC - R&~Identlal & Light Commercial HVAP--oads Program Elko Software Development, Inc.
Chris Jennings residential
Phoenixville, PA 19460 05-28-1999
Project Summary
Project residential Company: - Viglione Heating & Cooling Inc.
Client: Representative: STEVE VIGLIONE
Address: Address: 259 Commerce Street
City: MONTVILLE CT City: East HAVEN ct. 06512
Phone: Phone: (203) 467-8388
Fax: Fax: (203) 468-2596
Design Data
Project Name: residential
Reference City: New Haven, Connecticut
Daily Temperature Range: Medium
Latitude: 41 Degrees
Elevation: 6 Feet
Elevation Sensible Adj. Factor. 1.000
Elevation Total Adj. Factor 1.000
Elevation Heating Adj. Factor. 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter. -10 N/A N/A 70 N/A
Summer. 95 73 50% 75 22
Check Figures
Total Building Supply CFM: 1,400 CFM per square foot: 0.686
Square feet of room area: 2,040 Square feet per ton: 629.327
Building Loads
Total heating required with outside air: 84,845 Btuh 84.845 MBH
Total sensible gain: 29,952 Btuh 90 %
Total latent gain: 3,197 Btuh 10 %
Total cooling required with outside air. 33,149 Btuh 2.762 Tons (based on sensible + latent)
3.242 Tons (based on 77% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
RPVAC - Residential & UghtCommercial HVAa4, aft Program - Elite Software Development, Inc..
Chris Jennings f residential
Phoenbeville, PA 19460 05-28-1999 0 (~C N
Room Load Summary Reports
System #1 Room Load Summary
Htg Htg Run Run Clg Cig Clg Zone Cig Air
Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM
-Zone 1-
1 Area # 1 952 43,156 712 8-6 493 16,578 ' 1,451 775 1.25 942 775
2 Area 2 1088 41,689 688 6-6 531 13,374 1,746 625 1.00 608 625
System 1 Totals 2040 84,845 1,400 29,952 3,197 1,400 1,550 1,400
Wain Trunk Size: 20x12 in.
"Main Trunk velocity constraints were not met due to duct schedule limitations.
Main Trunk Air Velocity = 910 Feet/Minute
System #1 Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 2.762 900J10/10% 29,952 3,197 33,149
Recommended: 3.242 77%/23% 29,952 8,947 38,899
System #1 Equipment Data
Heating System Cooling System
Type: Natural Gas Furnace Standard A/C