HomeMy WebLinkAboutHeating/AC - SFR
Town of Montville
BUILDING DEPARTMENT
310 Norwich-New London Turnpike
Uncasville, CT 06382
(860) 848-3030, Ext. 382
Mechanical Permit
s
Permit Number: M2003-0051 Date: 15-Apr-03 Map/Lot: 037/002-047 Owner ID 2504
Job Location: 11 _ANDfRSEN_UUft_ Unit
Job Description: Heating & Air Conditioning
Owner: Contractor:
Hartens Pond LLC Viglione Heating & Cooling
259 Commerce Street
183 Quarry Road East Haven Ct. 06512-
Milford CT 06460 Telephone: (203) 467-8388
Lic/Reg Type/No.-S1 302380 Exp Date: 31-Aug-03
Tenant:
Self
Telephone:
Construction Values Permit Fees Construction Information
Building Value: $0.00 Building Fee: $0.00 Use Group: R4
Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 1995 CABO
Mechanical Value: $0.00 Mechanical Fee: $0.00 Construction Type: 5B
Electrical Value: $0.00 Electrical Fee: $0.00 Permit Code: R5
Other Value: $0.00 Other Fee: $0.00 Comments:
Total Value: $0.00 CO Fee: $0.00 Included on Building Permit
Plan Review Fee: $0.00
State Ed Fee: $0.00
Total Fees: $0.00
It is the owners responsibility to schedule the following inspections (minimum 48 hours mice req ui~ red).
❑ Footing - Prior to pouring concrete Rough HVAC
❑ Backfill - Footing drains and waterproofing ❑ Fireplace Throat
❑ Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble
❑ Rough Framing ❑ Firestopping/draftstopping
❑ Rough Electrical ❑ Insulation
❑ Electrical Service ❑ Final Inspection
❑ Rough plumbing and leak test ❑ Certificate of Occupany
❑ Gas piping and test
Building Official's Signature: -
i
04/02/02 01:24 FAS_84872-1,1 BUILDING DEPT 12101
Town of :i1+Mbnt e
Building Department Pwmit # 4,21-21-1 1--0
310 Norwich-New London Tpke.
Tel. 848-7166, Ext 82 Uncasville, CT 06382 Fax. 848-7231
One & Two Family Trades Permit Application Form
❑T(um&jW ❑E,ledricd [ 3N' ec(raracaf
xeat*
~/~iir Cmrdatioarg
Gas gepi
❑ot~
Job Locatione~'Sef1 L~
Job Description/Materials C> 4 Warm air h ea fi m u~ t4+1 C,c t ( conck ii (511,- n
_J j
Owner j' ~Z ,5 Mailing Address c ~
City State. Zip OL((Po Tel ,20/ :A
Contractor `f i ~~O' e~00~ '~-6X i Mailing Address &gct a(Y)(Y-~efcc
city State OF Zip 06-'50- _ Tel ~
Contractor's License/Reostration Type Number CS Exp. Date e 13 10-3
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the
State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee
and that T am authorized to make application for a permit for such work as described above.
Owner /Agent Signature Dated
Construction Value Fee
Building $
Plumbing $ $
Mechanical $ $
Electrical $ $
Other $ $
Certificate of Occupancy $
Plan Review Fee $
State Education $
Total S
- - - - - - - - - - -
i i
i
Sam JAVIJ
STATE OF CONNECTICUT ♦ DEPARTMENT OF CONSUMER PROTECTION
Be it known that
STEPHEN j VIG LIONS SR
259 COMMERCE ST
EAST HAVEN, CT 065°l2
has been certified by the Department of Consumer Protection as a licensed
HEATING, PIPING COOLING UNLIMITED CONTRACTOR
T'I'E: S1
License # 302380
Effective: 09/01/2002
/31
48
2-Q 0 Jam s T. Fleming, Commissioner
i i
Co'Lp
VIGLIONE HTG & CLG., INC. PROJECT: STERLING 2288 SQ FT
259 COMMERCE DRIVE CLIENT: DAMATO BROS
EAST HAVEN, CT 06512 DATE: 05/17/99
RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE
CLIENT INFORMATION:
NAME: DAMATO BROS
ADDRESS:
CITY, STATE: MONTVILLE CONN
TOTAL BUILDING LOADS:
BLDG. LOAD AREA SEN. LAT. + SEN =-TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-C WINDOW DBL PANE CLR GLS METL FR 210 12,180 0 4,440 4,440
12-I WALL R-19 +1/2"ASPHLT BRD(R-1.3) 2,234 9,829 0 2,902 2,902
11-C DOOR METAL POLYSTYRENE CORE 84 3,158 0 932 932
16-G CEILING R-30 INSULATION 1,232 3,252 0 1,789 1,789
19-A FLOOR/ENCL CRAWL HARDWD NO INS 2,288 28,554 0 0 0
SUBTOTALS FOR STRUCTURE: 6,048 56,973 0 10,063 10,063
PEOPLE 8 0 1,840 2,400 4,240
APPLIANCES 0 0 0 1,200 1,200
DUCTWORK 0 7,357 0 787 787
INFILTRATION W.CFM: 188.6 S.CFM: 94.3 0 16,596 2,629 2,074 4,703
VENTILATION W.CFM: 70.7 S.CFM: 70.7 0 6,223 1,972 1,556 3,528
SENSIBLE GAIN TOTAL 18,080
TEMP. SWING MULTIPLIER X 1.00
BUILDING LOAD TOTALS 87,149 6,441 18,080 24,521
SUPPLY CFM AT 80.10 DEG HTG DT: 919 CFM PER SQUARE FOOT: 0.520
SQUARE FT. OF ROOM AREA: 1,768 SQUARE FOOT PER TON: 865.218
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 87.149 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2.043 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE
VIGLIONE HTG & CLG, INC. EAST HAVEN, CT 06512
STERLING 2288 SQ FT 05/17/99 PAGE 2
ZONE # 1 ROOM LO;.kD SUMMARY *****************r***r***
RM ROOM AREA HEATING COOLING
NO. DESCRIPTION (SF) BTUH o TOT CFM BTUH o TOT CFM
1. WHOLE FIRST FL 816 38,262 47.3 435 7,944 48.1 442
2. WHOLE SECOND FL 952 42,664 52.7 484 8,580 51.9 477
ZONE SUBTOTAL 1,768 80,926 100.0 919 16,524 100.0 919
VENTILATION 6,223 1,556
LATENT. GAIN 6,441
ZONE TOTALS 87,149 24,521 2.043 TONS