Loading...
HomeMy WebLinkAboutSingle Family Residence Plans in File Town of Montville BUILDING DEPARTMENT 310 Norwich-New London Turnpike Uncasville, CT 06382 (860) 848-3030, Ext. 382 Building Permit Permit Number: B2004-0082 Date: 16-Mar-04 Map/Lot: 043/009-019 Owner ID 1755 Job Location: Unit Job Description: SFR Owner: Contractor: RTT Development RTT Development 35 Blais Road 35 Blais Road Uncasville Ct. 06382- Uncasville CT 06382 Telephone: (860) 889-1662 Lic/Reg Type/No. NHC 1795 Exp Date: 30-Sep-05 Tenant: Self Telephone: Construction Values Permit Fees Construction Information Building Value: $126,366.00 Building Fee: $760.00 Use Group: R4 Plumbing Value: $11,088.00 Plumbing Fee: $70.00 Code: 1995 CABO Mechanical Value: $6,072.00 Mechanical Fee: $40.00 Construction Type: 5B Electrical Value: $11,352.00 Electrical Fee: $70.00 Permit Code: R2 Other Value: $0.00 Other Fee: $0.00 Comments: Total Value: $154,878.00 CO Fee: $10.00 Plan Review Fee: $76.00 State Ed Fee: $24.78 Total Fees: $1,050.78 It is the owners responsibility to schedule the following inspections (minimum aft hours notice renuired): Footing - Prior to pouring concrete W-1 Rough HVAC © Backfill - Footing drains and waterproofing ❑ Fireplace Throat Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble Rough Framing Firestopping/draftstopping Rough Electrical ❑ Insulation d❑ Electrical Service CRS ❑ Final Inspection Rough plumbing and leak test Certificate of Occupany Gas piping and test Building Official's Signature: Town of Montville Residential Plan Review Date: M Aruc J11, 2©044 Job Address: 4:~-) ALL/ 5~eto 1.S 1.-1'.O Job Description: A- I3 kJ' We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute 29-263, your application is being rejected for the following reason(s) that are checked-off or commented on: • Supporting Documentation Access 18"x24" (409.2) Plans are to be drawn to scale including dimensions of rooms and spaces and all framing information (112.1) • Floor plan(s) rr&.,,Building permit application not completed, signed, dated Plans required Permit fee $4 ^ 62- 27 Dimensions Worker's comp. Affidavit or worker' comp. Insurance Finish floor elevation Copy Contractor's registration or license Minimum room sizes (304.1) Construction permit sign-off sheet Door and window sizes Provide all documentation to show compliance with the Model Kitchen layout Energy Code (1995 MEC). Contact your insulation contractor, Bathroom layouts, tub sizes in gallons, space clearances Northeast Smart Living Center (1-800-228-7764) or your local Stair location (min. width 36") (311.1) building official for information. Attic access location and size Street address of project on all drawings and documents Identify the use of each room Total square footage for each level of the structure • Site plan Indicate required light (8% of floor area per room) and ventilation Plans required (4% of floor area per room) for each habitable room or space (303. 1.) Finish floor elevation Indicate safety glazing in areas required such as: doors, windows, tub Signed by P&Z, Wetlands, Uncas health, WPCA & shower enclosures, etc. (308.4.) Property lines not provided Indicate bedroom egress windows (5.7 sf net clear opening, 24" clear Distance from property to structure opening height, 20" clear opening width) (310.2.1.) Structure dimensions Egress window maximum sill height 44" (310.2) Driveway Are basement stairs enclosed/accessible? If so, protect with minimum %2" sheetrock (310.3.) Topography (existing and proposed) Designate which door is the required exit (36" minimum, hinged) Footing drain inverts, outlet and separation Proposed utilities Garage Wetlands and flood zone limits and elevations Minimum 5/8" Type X gypsum board separation (on garage side) to all living spaces - all combustible support framing to be covered with minimum 5/8" Type X gypsum board if it supports habitable rooms • Foundation Plan (309.2) Plans required Indicate minimum 1 '/V solid wood door, 1 3/." solid core steel door, 1 Dimensions '/I' honeycomb core steel door, or 20 minute rated door from the Wall thickness garage to the house and its basement or attic (309.1) Footing sizes Indicate self. closing devices on all doors from garage to the house Frost protection required and its basement or attic (309.1) Window and door sizes and locations Indicate slope for garage floor (309.3.) Hatchway Foundation - indicate the assumed soil conditions that the system has • Elevations been designed for or provide engineering data. If presumptive soil Plans required conditions cannot be met, provide soil bearing engineering data (401) Type of siding Concrete strength - foundation, floors, exterior porches, walks, slabs (402.2) Type of roofing Basement - finished of unfinished? Other finishes Vapor barrier between sub-grade and concrete basement floor Finish grades Building heights (505.2.3) Dimension height of chimney above roof Minimum height of foundation walls above finished grade (404.1.3) Roof pitches Perimeter insulation, if conditioned space Anchor bolts - size and location (403. La) Floor thickness and control joint location (403. La) • Building Section(s) & Details Lally column size, attachment and spacing (408) Plans required Column footings - size (403) Floor-to-floor heights Waterproofing details (406) Handrails and guardrails detail, including height and maximum Rebar if required - wall length, unbalanced fill, or soil conditions will opening, handrail cross-section, continuity and required returns determine this. Provide engineering data for complex design. Riser height (8 '/V max), tread depth (9" min.), and nosing (3/4" - 1 Fireplace/chimney base Concrete piers and anchor details - decks Show minimum headroom in stairways - 6'-8" measured from nosing Foundation drainage - sump, drain to grade, or town storm system; plane to lowest point of ceiling indicate pitch (405.1) Stud size and spacing, species and grade (or minimum Fb and E) Beam pockets - minimum clearances Sheathing - size, thickness, type Crawl Spaces Siding, material, type, style - underlayment per mfg. Crawl space data - clearance to joists, slab thickness (if provided), Insulation - R-value, type - including basement walls if applicable vapor barrier (409) Flashing detail - windows and doors - type, material Ventilation (499.1) Town of Montville *111110 • Framing plans Decks/Porches Plans required Plans required Bearing partitions Joists - size, span, spacing, direction, species and grade (or minimum Direction of framing Fb and E) Beam spans, size, species, grade Ledger - show attachment and flashing to house Framed openings Decking material and size Sheathing type and thickness Beam - design data if required Window and door header sizes Posts - size, material, and height Joists - species and grade (minimum Fb and E), size, direction, and Piers - size, material, depth below grade (minimum 42" required) Indicate joist hangers at flush framing and ledger spacing Joists over-spanned Stairs, handrails, and guardrails Headers/beams overspanned Double joists at parallel bearing partitions, bathtubs, etc. (502.3.2) • Chimneys and Fireplaces Details of framing for plumbing, such as headers and trimmers at Indicate clearance of masonry to combustible framing materials and traps, etc. clearance from fireplace opening to finished trim Joist hangers for flush framing conditions or ledger (502.4.2) Show data for mechanical flue sizing Deck material, type, size, and span Show exterior combustion air source Floor insulation - R-value, type, vapor barrier location Flue sizes Provide design data for all unaligned wall and floor bearing points. Manufactures data and installation instructions for metal fireplaces Indicate location of all point loads Cantilevered framing less than 18" to grade to be pressure treated or • Electrical Plan(s) decay resistant Plan(s) required Engineering data for steel beams, engineered lumber, roof trusses or Panel location(s) with main size any other engineered product or design Roofs/ceilings Meter socket location Outlet locations Provide roof framing plan for roof geometry Ceiling joists - spacing, span, direction, species and grade (or GFCI outlet locations minimum Fb and E) Lights and switches Rafters - pitch, spacing, span, species, and grade (or minimum Fb Appliance/equipment circuits and E) Stair illumination Insulation - R-value, type - including basement walls if applicable Stairway light activation at both top and bottom of stair (303.4) Ventilation - ridge, gable, soffit Show required AC/DC smoke detectors (316) Provide minimum net ventilation data Attic access (22"x30" minimum) for any attic with 30" or more clear • Mechanical plan(s) height Pplan(s) required Roof sheathing - type, size, thickness Dryer vent Collar ties - size, placement, spacing Bathroom exhaust ventilation (natural or mechanical) type and size Roof covering - shingles - type, nailing, provide proper with calculations underlayment - show interior horizontal distance of double Hood exhaust underlayment at cave, etc. Type of heat Overhang detail Heating, ventilation, and air conditioning plant locations Provide framing details of trayed/vaulted ceilings Oil/LP-gas tank size, location and piping Provide detail of cathedral ceiling structure and venting Make-up air requirements Indicate connection of lower chord of roof trusses and ceiling joists to Manufactures data for equipment the top plates of interior and exterior walls. Calculate roof tie-down Heat loss/gain calculations sizes when required by wind conditions Show framing for gables in cathedral ceiling construction • Plumbing plan(s) Provide engineering data for all roof trusses - (truss drawings must be Plan(s) required signed and sealed by a Connecticut Licensed Professional Engineer) Building trap location Roof rafters over-spanned Ceiling joists over-spanned Sewer location Domestic water location Manufacturers data for whirlpools, comer tubs, & larger tubs Water heater size, type, and location Comments: i io-I 7J O'i -ror- ayo g0 Town of Montville _ Building Department Permit # 310 Norwich-New London Tpke. Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax. 848-7231 One & Two Family Building Permit Application Form New Construction. ❑ Addium R ACteration Accessory Structure Other Job.Location ~.c9 Job Description/Materials_ Owner /T Y' Mailing Address City l/~✓ G.~ S ~i / ` State C-I Zip Tel Y 1 Contractor Mailing Address City State Zip Tel Contractor's License/Registration Type & Number ✓ `2 w Exp. Date `j i 3 I I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Owner /Agent Signature Date Construction Value Fee Building $ 36 $ 7?,60 Plumbing off--' 70 Mechanical $ 6o 7 Z^ $ Y0 Electrical ~sz^ $ 9 0 Other $ $ Certificate of Occupancy /0 Plan Review Fee $ 79. State Education 7y Total. $ (See Reverse side for addiuonaf requirements) ^4 Town of Montville Residential Permit Requirements ❑ Two (2) complete sets of construction documents (to scale) are required and shall show the following information if applicable. This list is not all-inclusive, additional information may be required for your particular project. • Supporting Documentation • Building Section(s) & Details Competed. signed and dated Building Permit Application Floor-to-floor heights Permit fee - calculated upon completion of plan review Material type, size, and spacing Completed building permit affidavit for property owners or sole Stair details (rise, run, treads, nosing, width, headroom) proprietors or copy of workers compensation insurance Handrail details Copy of Contractor Registration or license Guardrail details Construction permit sign-off sheet signed by all departments Roof ventilation Model Energy Code Analysis Heat loss calculations • Framing plans Engineering data for steel beams, engineered lumber, roof trusses or any Design loads - for floors, ceilings, roofs other engineered products or design Bearing partitions Street address of project on all drawings and documents Direction of framing Spans, beam • Site plan Wood species and grade Property lines Framed openings Distance from property to structure Sheathing type and thickness Structure dimensions Window and door header sizes Driveway Decking material, size, spacing Topography (existing and proposed) Note: Unusual structural conditions may require that additional Footing drain inverts, outlet and separation engineering back up be submitted Proposed utilities Wetlands and flood zone limits and elevation • Chimneys and Fireplaces Signed by P & Z, Wetlands, Uncas Health, WPCA Clearances to combustible materials Manufactures data for metal flues • Foundation Plan Exterior fresh air source for fireplaces Assumed soil bearing pressure Flue sizes Dimensions Manufacturers data and installation instructions for metal fireplaces Wall thickness Footing sizes • Electrical Plan(s) Anchor bolts, size and spacing Panel location(s) with main size Window and door sizes and locations Meter socket location Hatchways Outlet locations Columns GFCI outlet locations Floor construction data Smoke detector locations Drainage details Lights and switches Waterproofing details Appliance/equipment circuits Crawl space ventilation Stair illumination Crawl space access Concrete strengths • Mechanical plan(s) • Floor plan(s) Dryer vent Bathroom exhaust ventilation (natural or mechanical) type and size Dimensions Hood exhaust Door and window sizes, egress window Type of heat Glazing in hazardous locations Beating, ventilation, and air conditioning plant location Garageldwelling opening protection Oil tank size, location, and piping Garage/dwelling separation LP-Gas tank location, size, and piping Kitchen layout Make-air requirements Bathroom layouts, tub sizes in gallons, space clearances Manufacturers data for equipment Indicate use of all rooms Stair location Attic access location and size • Plumbing plan(s) Square footage for each habitable level of the structure Building trap location if on municipal sewer Required light and ventilation for each habitable room Sewer location Domestic water location • Elevations - minimum of two required Manufacturers data for whirlpools, comer tubs, & larger tubs Type of siding Water heater size, type, and location Roofing Other finishes Note: One set of approved plans is required to be kept on Finish grades Building heights site at all times. Height of chimney above roof Roof pitch Town of -ontviVe Building Departm' A Receipt Date No. 0, -6 'S From: r y z y, Job Address: Amount $ ' r r Cash Chcck~ Check t 006 one) ' Received by, Permit # C t v STATE OF CONNECTICUT WORKERS' COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn. Gen. Stat. § 31-286b) Property located at In the town of Name of building permit applicant: 7 T-~v~-~~o .ate Please check one: 1. 0' I am the owner of the above property. 2. I am the sole proprietor of a business. 2A. Name of business: 213. Federal Employer Identification Number (FEIN) Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or principal employer" may provide either a certificate of workers' compensation insurance or a "sworn affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: 1. I do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2. C_ I intend to act as a general contractor or principal employer. Applicant must either provide a certificate of workers' compensation insurance or sign the affidavit below. Affidavit - - I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor, subcontractor, or other worker before he/she engages in work on the above property in accordance with the Workers' Compensation Act (Chapter 568). I understand that pursuant to § 31-275 C.G.S., officers of a corporation and p rs in a partnership may elect to be excluded from coverage by filing a waiver with the appropni s . ffice; and that a sole proprietor of a business is not required to have coverage unless he files.- to cept coverage. Signature of applicant Subscribed and sworn to before me this day of a- r , 200 . (Notary Public/Commissioner of the Superior Court) LINDA L. ROBERTS .Pi oT Y PUBLIC ,,AY COMMISSION EXPIRES OCT. 39, 2007 HOME CONSTRUCTION CONTRACTOR NEV RM DEVELOPMEI~'r 35 BLAIS RD ETC kSVILLE, Cr 06332 EXPIRES EFFECTIVE 09 /2005 LIO.JREG NO. lOIOI I2~03 1795 x SIGNED i Town of Montville f Building Department 848-3030, Ext 382 ONE & TWO FAMILY CONSTRUCTION PERMIT SIGN-OFF SHEET Property Address Job Description: -r- (C- The owner/agent shall be responsible for the completion of the form, no certificate of occupancy will be issued until aH signatures below have been obtained. HEAL DISTRICT 848-3030-339 S D / / Approved Not Permit A kjQ Permit 1. 7` ❑ Required tic Sy e Date Approved Not Permit ❑ Permit ❑ Required Private Well Date WPCA DEPARTMENT 848-3030, Ext 376 Approved Not Permit ❑ Permit ❑ Required Municipal Sewer Date House Trap ❑ Outside ❑ Inside Approved Not Permit ❑ Permit # [j Required Municipal Water Date DEPARTMENT OF PUBLIC WORKS 848-7473 Approved Not Permit Permit ❑ Required i~iWeter Date PLANNING & ZONING DEPARTMENT 848-3030. Ext. 379 Approved Not Permit 2 / Z ❑ Permit # ❑ Required Zoning Date Approved Not Permit ❑ Permit ❑ Required Inland-Wetlands Date