Loading...
HomeMy WebLinkAboutSolar PV Field Inspection Notice Town of Montville Building Department December 9, 2008 Address; 7 Allison's Way Job Description: install Solar PV Permit Number(s) E2008-0222 Permit Date: November 19, 2008 Not Approved Approval F INSPECTION Date: Deficiencies Special Date Conditions Fastened to 12/9108 CC Roof Panels rafters Basement Installation 1219108 CC • conduit 1219108 CC Attic Final inspection for • outside 1219108 CC disconnect certificate of approval Page 1 of 1 Rev. Date: 1/18/06 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 ELECTRICAL PERMIT Permit Number: E2008-0222 Date: 19-Nov-08 Map/Lot: 035/009-018 Owner ID: 54000 Project Location: 7 ALLISON'S WAY Unit: Job Description: Solar PV Installation Owner Name: Todd M and Renee C Frechette Tenant Name: N/A Careof: 7 Allison's Way Oakdale CT 06370- Telephone: (860)889-2888 Contractor Name: Mark Waldo Telephone: (203)494-9266 DBA: Waldo Renewable Electric Lic/Reg Type: El Lic/Reg No: 192179 P.O. Box 244 Exp Date: 30-Sep-09 Old Lyme CT 06371- Construction Value Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: $0.00 Mechanical Fee: $0.00 Electrical Value: $37,500.00 Electrical Fee: $304.00 Construction Type: IRC Total Value: $37,500.00 Penalty Fee: $0.00 Permit Code: R5 C of 0 Fee: $0.00 Comments: Plan Review Fee: $0.00 State Ed Fee: $6.75 Total Fee Paid: $310.75 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business davs in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING MECHANICAL ELECTRICAL PERMIT INSPECTIONS ❑ Footing - Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Elec Trench - with conduit installed ❑ Backfill -Footing drains and waterproofing ❑ Concrete Slab - Prior to pouring concrete ❑ Pool Bonding ❑ Electrical Service CRS No: 0 ❑ Anchor Bolts -with sill plate and prior to floor framing ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking -Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation V Certificate of Approval Ce dfe of Occupancy Building Official's Approval. Town of Montville ) - Kkt: . Building Department 310 Norwich-New London Tpke. Fax. 860-848-7231 Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 RESIDENTIAL PERMIT APPLICATION FORM Permit No.:,SQ00's-0 Type of Work Occupancy Type Permit Type ❑ New Construction ❑ Single Family ❑ Building ❑ Addition ❑ Two-Family ❑ Plumbing ❑ Alteration ❑ Townhouse ❑ Mechanical ❑ Accessory Structure 'Electrical CRS#: Job Address: (Num (street) (unit) bePr) Job Description: Owner: ~.I1 11 Address: IV V~C C f State: -C~ Zip Code: 0f City: Q~ Telephone: Contractor: ~i le L:i ~ t 14, XZ i 0. 4 L DBA _j0 Address: ~~3 - State: Zip Code. City: Telephone: License Type: License No.: Expiration Date: 7L° I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the owoosed work is authorized b the owner in fee and that I am authorized to make a lfca#on for a permit for such work as described above ❑ By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner /Agent Signature: Date: ~ Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: _ Total Value: Penalty Fee: C of O Fee: Plan Review Fee. State Ed Fee: Total Fee: d August 23, 2007 Residential Permit Requirements Checklist its list is to be used as a guide only and is not all-inclusive, additional information may be required for your particular Dject Two complete sets of construction documents required. pvided Not Item A livable i ortin Documentation Provided A livable Item I Completed, signed and dated Building Permit Building Section $ Details Application Completed worker's compensation affidavit for Floorial typo, hey hts property owners or sole proprietors or copy of Stair Materrial details (rise, a ri ands acn workers com nation insurance se, run, treads, nosing, width, Co of Contractor Registration or license headroom Construction permit sign-off sheet signed by all Handrail details departments Guardrail details Documentation showing compliancewith the Roof ventilation Energy Conservation Code Framin Plans a211eneraucades.~w orChapter 11 Deli nloads-for floors ceifn s, roofs Street address of project on all drawings and Bean rtitions identified on the plan documents Direction of framing S ns beam ind Limitations Criteria Wood species and fade Documentation showing compliance with the Framed openings requirements for construction in 110 mph wind Wall framing size and s acn identified zone Sheathing a and thickness Design publication identified; WFCM-2001, Window and door header sizes chapter 2; WFCM-2001, chapter 3; SSTD 10-99; Deckin material, size, spacing ASCE 7-02, AISI, COFS/PM Engineering data for engineered lumber (LVUs and 1= oists to Plan Framing n for enconeered lumber roperty lines Engineering data for steel beams, signed and Distance from property to structure sealed a CT reistered deli n professional Structure dimensions Engineering data for trusses, signed and sealed Driveway b a CT istered Professional Engineer Topography existin and proposed) Note: unusual structural conditions may require that additional engineering back u be submitted Footin drain inverts, outlet and separation Pro peed utilities Chimneys & Fireplaces Wetlands and flood zone limits and elevation Clearances to combustible materials Se tics em shown and located on the an Manufactures data for metal flues Well and piping shown and located on the plan Exterior fresh air source for firelace i rundation Information Flue sizes Assumed soil bearing pressure Manufacturers data and installation instructions Dimensions for metal fireplaces Wall thickness Electrical Information Footing sizes Panel locations with main size Frost protection Meter socket location Foundation anchor type, size, locations GFCI outlet locations Window and door sizes and location Smoke detector locations Hatchways lights and switches Column Mechanical Information Drainage details Dryer vent Wale rnofin details Bathroom exhaust ventilation (natural or Crawls ce ventilation size and location mechanical) type and size Crawlspace access size and location Hood exhaust Concrete slier s Type of heat oil electric, as oor Plan Information meeting, ventilation, and air conditioning plant Dimensions location Door and window sizes ress window Oil tank size, location, and i in Glazin in hazardous locations LP-Gas tank location, size and piping Gana e/dwellin o ni protection Combustion air requirements ManuFac4rrers data for equipment Garage/dwelling separation Kitchen la ut Heat Toss, Heat air calculation Bathroom layouts, tub sizes in gallons, space Plumbing Information clearances Building trap location if on municipal sewer Indicate use of all rooms Sewer location Stair location Domestic water location Attic access location and size Water heater size, type, and location Square footage for each habitable level of the Manufacturers data for whirlpools, comer tubs, & larger tubs structure Required light and ventilation for each habitable room !evations Type of siding Roofing Other finishes Finish grades Building heights Height of chimney above roof Roof itch +i I Town of Montville Building Department File Receipt Receipt No: 4080 Date: 17-Nov-08 Received From: Waldo Renewable Electric Job Address: 7 Allison's Wa Fees Collected state Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $6.75 Check: $310.75 Check No: 764 Short/Over: $0.00 $37,500.00 Construction Value: Demolition Value: $0.00 Received By Carmen Roberts ` Address: 7 Allison's Way TOTAL ITEM QTY $/UNIT Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 113.03 $ - $ - Basement, Finished SF $ 22.96 $ - $ Basement, Unfinished SF $ 12.40 $ - $ - CraW Sapce SF $ 9.30 $ - Interior Renovations SF $ 35.09 $ - $ $ - MANUFACTURED HOMES Ground Anchors SF $ 6.45 $ $ - $ - Basement SF $ 12.41 $ - $ - $ Crawl Space SF $ 9.31 $ - $ - $ " AMENITIES _ Kitchen EA $ - $ $ Full Bathroom EA $ $ Half-Bathroom EA $ $ GARAGE Attached SF $ 54.35 $ - $ - Detached SF $ 69.53 $ - $ Under SF $ 10.03 $ - $ Carport SF $ 19.89 $ - MECHANICAL Warm-Air n YIN $ - Hot Water n Y/N $ Electric n Y/N $ Air Conditioning n YIN $ - ELECTRICAL SERVICE Upgrade Arnps $ _ Overhead, new Amps $ Underground, new Amps $ Subpanel EA $ 599.50 $ Gen Set EA $ 3,850.00 $ SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry wit fireplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove, free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS, PORCHES, SUNROOMS Deck SF $ 43.07 $ - Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ POOLS & HOT TUBS Hot Tub EA $ 8,016.25 $ - $ Inground Pool EA $ 21,373.44 $ - $ - Above Ground Round EA $ 5,099.46 $ - $ Above Ground Oval EA $ 6,019.75 $ - $ Pool Heater EA $ 8,984.25 $ - Inflatable Type Pool EA $ 1,550.00 $ - SHEDS w/o electrical SF $ 20.35 $ wlelectrical SF $ 20.35 $ - $ RENOVATIONS Roofing, Overlay SF $ 3.00 $ - Roofing, Strip & reroof SF $ 4.00 $ Roof Sheathing SF $ 1.31 $ - Siding SF $ 3.50 $ - Windows EA $ 500.00 $ Skylights EA $ 1,051.10 $ - Doom, Exterior EA $ 601.50 $ - Oil Tank, 275 Gallon EA $ " Oil Tank, 550 Gallon EA $ MISCELLANEOUS CALCULATIONS $ 37,500.00 TOTALS $ - $ - $ - $ 37,500.00 PERMIT FEE CALCULATIONS Construction Value Fee Building $ $ - Plumbing Y $ $ Mechanical Y $ $ - Electrical Y $ 37,500.00 $ 304.00 Working before Permit Issuance $ Certificate of Occupancy Fee $ Plan Review Fee $ - State Education Fee $ 6.75 TOTALS $ 37,500.00 $ 310.75 Figures are based on the 2006 RS Means Residential Cost Data NEW NEW ELECTRICAL UNLIMITED CONTRACTOR MARK WALDO 6 LITTLEFIELD DR ~ OLD LyME, CT 06371 EI FECTIVE EXPIRES ]C. / REG NO IELC.0192179-E1 10/01/2008 09/30/2009 SIGNED_,,-.,_-_ M Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL i ®0 Proper(y Address V' PV &M Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Department Permit Issuance Approval Approval / O 8 Tax Collector Required for aff permits Comments: ® WPCA, Administrative Required for properties on sewer Comments: ❑ WPCA, Operations When Required by WPCA Comments: ® Planning & Zoning Required for aJJ permits ® Health Department Required for properties with septic systems - Not required for Plumbino Electrical Mechanical Roofing Siding Windows & Doors Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage reauimments Comments: ❑ State Dept. of Transportation Recurred for Structures over 100 Os a tt or with more than 200 parkins spaces - Official copy of STC Certificate of Operation required -per CGS 14-311 Comments: L n Vc~ Fire Marshal Required for aJJ permits Comments: Q [ Cl__1-:-~-~ (,mil dnzWU9s, 20as Think GAIA For Life and the Earth SR&O HIT Photovoltaic Module 0'ower ®t Aodule Efficiency: 17.2% - Cell Efficiency: 19.7% Hlower Output - 200 Watts Module Photovoltaic a ; kNYO HIT ® Solar Cell Structure k p-type/i-type (Ultra-thin amorphous silicon layer) Thin mono ant- de rode ~s { crystalline LL silicon wafer High Efficiency rrode n - HIT® Power solar panels are leaders in sunlight conversion efficiency. Obtain 7- -L maximum power within a fixed amount of space. Save money using fewer system i-type/n-type attachments and racking materials, and reduce costs by spending less time install- (Ultra-thin amorphous silicon layer) ing per waft. Power Guarantee Unnecessary Section When Using SANYO SANYO's power ratings for HIT Power panels guarantee customers receive 100% of the nameplate rated power (or more) at the time of purchase, enabling owners to generate more kWh per rated watt, quicken investment returns, and help realize` complete customer satisfaction. AT Performance P As temperatures rise, HIT Power solar panels produce 10% or more electricity t (kWh) than conventional crystalline silicon solar panels at the same temperature. ~ a r Proprietary Technology HIT solar cells are hybrids of single crystalline silicon surrounded by ultra-thin amorphous silicon layers, and are available solely from SANYO. HIT Power models _ are ideal for grid-connected solar systems, areas with performance based incen- tives, and renewable energy credits. Structural Strength HIT Power panels have a double-wall black anodized aluminum frame for extra strength, and are tested to 60PSF. The panels come pre-equipped with a touch- Increased Performance with SANYO safe junction box, USE-2 outdoor rated cables, MC4TM locking connectors, and are UL 1703 safety rated for wind, hail, and fire. . °C 0.8 Approx. Module Temp _ .75 - Valuable Features 8 10%pUp HIT HIT Power solar panels operate silently, have no moving parts and are among the o lightest per waft in the industry. Unique eco-packaging minimizes cardboard waste at the job site. The packing density of the panels reduces transportation, fuel, and os storage costs per installed watt. O Quality Products SANYO silicon wafers located inside HIT solar panels are made in California USA, Kobe (Japan), July 24, 2007, and the panels are assembled in an ISO 9001 (quality), 14001 (environment), and z° Faced due South Tilt angle 30° 18001 (safety) certified factory. The panels have a Limited 20-Year Power Output and 5-Year Product Workmanship Warranty. 5 am 7 am 9 am 11 am ,pm 3 pm 5 pm 7 pm Time olm 7: 77'.. - Electrical Specifications HIT Power 200 Dependence on Temperature' ' 200 W Rated Power (Pmax) Maximum Power Voltage (Vpm) 55.8 V 4.50 Maximum Power Current (Ipm) 3.59 A Open Circuit Voltage (Voc) 68.7 V 4.00 76°C Short Circuit Current (Isc) 3.83 A 50°c 3.50 Minimum Power (Pmin) 190.0 W 25°C Temperature Coefficient (Pmax) -0.29% / °C Q 3.00 - Temperature Coefficient (Voc) -0.172 V / °C o°C Temperature Coefficient (Isc) 0.88 mA / °C 2.50 Cell Efficiency 19.7% U 2.00 Module Efficiency 17.2% Watts per Ft.2 16.0 W 1.50 Maximum System Voltage 600 V Series Fuse Rating 15A 1.00 - - Warranted Tolerance 0% / +10% 0.50 Specifications Internal Bypass Diodes 4 Bypass Diodes 0.00 Module Area 12.49 Ft.2 (1.16m) 0 10 20 30 40 50 60 70 80 Weight 33.07 Lbs. (15kg) Voltage (V) Dimensions LxWxH 51.9x34.6x1.8 in. (1319x880x46mm) Cable Length-Male/+Female 30.7/24.8 in. (7801630mm) Dependence on Irradiance' Cable Size / Connector Type No. 12 AWG / MC4T Locking Connectors Static Wind / Snow Load 60PSF (280013a) / 39PSF (1867Pa) 4.50 i Pallet Dimensions LxWxH 53x35x77 in. (1346x897xl952mm) 4.00 i000W/m2 Quantity per Pallet/ Pallet Weight 34 pcs. 11102 Lips. (500kg) Quantity per 20', 40', and 53' Container 340 pcs., 714 pcs., 918 pcs. 3.50 800W/m2 Operating Conditions & Safety Ratings 3,00 Ambient Operating Temperature -4°F to 115°F (-20°C to 46°C)2 NOCT 116.6°F (47.0°C) N 2'50 600W m2 Hail Safety Impact Velocity 1" hailstone (25mm) at 52 mph (23m/s) M 2.00 - - Fire Safety Classification Class C fJ 400W/m2 Safety & Rating Certifications UL 1703, cUL, CEC 1'50 - - - { Limited Warranty 5 Years Workmanship, 20 Years Power Output 1.00 ' 'STC: Cell Temp. 25°C, AM1.5, 1000W/m2 2Monthly average low and high of the installation site. 2~W m2 Note: Specifications and information above may change without notice. 0.50 - Section A.A' 0.ao 0 10 zo 3o 40 so so 70 so Dimensions Voltage (V) Unit: inches (mm) °D 0.5 (13) 34.6(880) 1.8(46) 17.3 (440) 1.5(37) ACAUTION! I Read the operating instructions carefully before use of these products p 0.205 (5.2) 0.165 (4.2) M M 0.276 (7) 0.276 (7) M A A 4x mounting holes SM&O rn SANYO Energy (U.S.A.) Corp. Solar Division 0.276(7) 0.276(7) 2600 Network Blvd., Suite 600 Ground (4 places) Frisco, TX 75034, U.S.A. www.sanyo.com/solar solar@sec.sanyo.com 0.165 (4.2) 0.205 (5.2) Front Side Back 0 SANYO Energy (U.S.A.) Corp. All Rights Reserved. 6/1/2008 F > Certified to the new U L 1741 /IEEE 1547 > 10 yr. standard warranty > Improved CEC efficiency 1 > Integrated load-break _ h rated DC disconnect switch 4 > Integrated fused series string combiner > Sealed electronics enclosure & Opticool ' > Comprehensive SMA communications and q { data collection options` > Ideal for residential or light commercial applications y Rugged cast aluminum outdoor rated enclosure V z~ . a Sunny Boy 3000 4000 The in their class SMA is proud to introduce our new line of inverters updated with our latest technology and designed specifically io'meetthe new IEEE 1547 requirements. Compact design makes them ideal for residential use and the integrated DC disconnect makes installation more cost effective. They are field-configu- 'for positive ground syste-ms'making them more versatile than ever. Increased efficiency means L US c UT better performance and shorter payback penods. With over 500,000 fielded units, Sunny Boy has become thebenchmark for PV inverter performance and reliability throughout the world. hZ4r en re ~.7w.a .;iR .'.~„dy3,.,..:e Ye'1. - •..R ~ r ~ - Technical Data f nn.y Boy .3000 j 4000 SB 3000US SB 4000US ?5 x;, Input Data (DC) B~ Max. Recommended Array Input Power (DC @ STC) s/ou W 5000 W Max. DC Voltage 500 V 600 vr.. Peak Power Tracking Voltage 180 400 V @ 208 V 220 - 480 V @ 208 V 200 400 V @ 240 V 250 - 480 V @ 240 V 18A DC Max Input Current 17 A DC Voltage Rple <5% ..v Number of Fused String Inputs 4 4 PV Start Voltage (adjustable) 228 V 285 V Output Data (AC) AC Nominal Power uµ 3n0 3500 W @ 208 V / 4000 W 9 240 V ' a3* t AC Maximum Output Power 306 4000 W AC Maximum Output Current 15 A@, 208 V 12F5 A @ 240 V 1 A @ 208 V, 16 6 A @ 240 V AC Nominal Voltage / Range 183 - 229 V @ 208 V 183 - 229 V @ 208 V 211 -264V@240V 211 -264V@240V a. AC Fre l ency /flange{" 60 Hz I A9.3 H- 50 5_ Hz 60 Hz / 59 3 Hz.- 60.5 Hz r Power Factor mm. 1 a ° Ef iaency Peak Inverter Efficiency mw 3 CEC weighted Efficiency AWechanical Data L a Dimensions W x H x D in inches _ 178 x 13.8 x 9.3 0 Weight W Ihs / 94 Ibs 88 Ibs / 94 Ibs Ambient temperature range -13 to +113 F -13 to +113 OF Power Consumption standby/ nighttime <7W/0.1 _W < 7 W/_O 1 W Topology PWM,ttrue sinewave, PWM, true sinewave, y current source current source i a Cooling Conceptn Convection, regulated fan cooling Convection, regulated fan cooling g m y m F»-MV • S' Mounting Locati on Indoor/ Outdoor (NEMA 3R) ~eatures ' s" LCD Display • ~ro Lid Color: aluminum / red / blue / yellow •/U/O/O n •i Jj Ji J . Communication: RS485 /Wireless O/O F O/0 Warranty: 10-year • • Compliance: IEEE-929, IEEE 1547, UL 1741, UL 1998, FCC Part 15 A & Bm • • o _w, a K Specifications for nominal conditions • Included O Option - Not available a Efficiency Curves 98 wA4*d. SiO.i-` ±±.r+.x - hy,. '3 96 94 Uw -2250 V DC a" 92 V DC - - Uw-0 ±s~ Uw-480V DC 90 ems- o c C; { 86 SB 4000U5 1: 1 t. N 1000 2000 3000 4000 5000 6000 7000 PAC Iwl 1 QQ ;i7. .yea v www.sma-america.com Phone 530-273-4895 Toll Free 888-4SMAUSA SMA America, Inc. . t I I / > Certified to the new UL 1741/IEEE 1547 > 10 yr. standard warranty w > Highest CEC efficiency in its class > Integrated load-break rated AC and DC disconnect switch 3 a .f .-n r w w . ,n`F \ > Integrated fused series F string combiner t a > Sealed electronics - enclosure & Opticool > Comprehensive SMA communications and data collection options > Ideal for residential or commercial applications { w. > Sunny Tower . compatible 74 772. Sunny Boy 5000 6000 7000 The best in their class SMA is proud to introduce our new line of inverters updated with our latest technology and designed specifically to meet the new IEEE 15,47 requirements. The SM0000 and SB7000U are also compat- ible with SMA's new Sunny Tower. Increased efficiency means better performance and shorter payback periods. All three models are field-configurable for positive ground systems making them U(~) L u s atile than ever. With over 500,000 fielded units, Sunny Boy has become the benchmark for PV inverter performance and reliability throughout the world. x ~Y Technical Data ~t S uhn n y B ay 000 /6000 17000 SB 5000US SB 6000US SB 7000US Input Data (DC) Max. Recommended Array Input Power (DC @ STC) o250 W 7500 W 8750 W Max. DC Voltage 600 V 600 V 600 V Ca.~ Y ...w. . mac... a<.wn.+m....wa...h...~,... _..w<.,.a.~n a+....we a tG Peak Power Tracking Voltage 250 480 V 250 - 480 V 250 - 480 V n f DC Max. Input Current 21 A m 25 A 30 A„ F. DC Voltage Ripple Number of Fused Strang Inputs 4 4 4 - ~ y PV Start Voltage 300 V 300 V 300 V Output data (AC) ~e* AC Nominal Power 5, 6000 W 7000 W 5 AC Maximum Output Power 5000 W 6000 W 7000 W e r AC Maximum Output Current (@ 208 240 277 V) 24 A, 20.8 A, 18 A 29 A 25 A 21 6 A 34 A 29 A 25.3 A AC Nominal Voltage/Range + 183-229V@208V 183 - 229V@208V 183-229V@208V o 211 - 264 V @ 40V 211 - 264 V @ 240 V 211 - 264 V @ 240 Va 244 305 V@ 277V 244 - 305 V @ 277 V - 244 - 305 V @ 277V AC Frecuenc / Ran a 60 Hz /593 H. 60S Hz WA;/59.3 Hz 605 Hz 60 Hz /59.3 Hz 60.5 Hz Power Fnctnr 1 1 w 1 r Efficiency r S Peak Inverter Efficiency _ CEC weighted Efficiency V v.. - o @ 208 V 3.5 % @ 208 V 240 V o.< 11 @ 24n wi 3 3~ v 277 V 96 Cod 27: 0 c anical Data s Dimensions W x H x D in inches 188 x24.1 x'1,5 .1 x:A.l xy.5 18A AiAJ xy.5 ~ Weight / Ship ing Weight 143 Ibs / 154 Ibs 143 lb-, -/154 Ibs ? 143Ibs / 154 Ibs a Ambient ter perature range m -13 to +113 *F -13 to +113 *F -13 to +113 'F Power Consumption: tandb nighttime < 7W/0.25W <7 W 0.25 W Y/ gm / <7W/0.25W - . _ PW b sinew . Topology M true sinewave PWM true sinewave PWM true sinewave, current source current source, M current source Cooling Concept Convection with Convection with Convection wit h o 14. r_rn~lOtA ! fan 10olin", g t I fan oolin regulated fan coolin Mountinq Location Indoor/ Outdoor (NEMA 3R) 0 ; i~ - Featw des.. LCD Display Lid Color: aluminum / red / blue / yellow •/O/O/O Communication: RS485 / Wireless wck" Warran : 10- ear Compliance: IEEE-929, IEEE 1547, UL 1741, UL 1998, FCC Part 15 A & B Specifications for nominal conditions • Incbded O Option - Not aw-il!ble " Efficiency Curves 98 96 I - 94 / d8 94 U - 250 V DC r-A...eia _ ••f ••I.•: ii 11 ? - U -3'.OV DC +....~4 rildai.wr 'MM C ^I 1000 4000 3000 Iw1000 5000 6000 7000 PAC t 2 u N www.sma-america.com Phone 530-273-4895 Toll Free 888-4SMAUSA SMA America, Inc. S 11 F1 LI 4 Iii ~ Q~ Notes: 1. PV Array is 4 pole mounts approx. 100 feet from Main Panel 2. Junction Box/ Combiner Box/ DC Disconnect 3. Inverter (DC/AC Disconnect) 4. Main Panel 5. Meter - located outside 6. 1 iichconduitPVC 7. AC Utility Disconnect - located outside Waldo Renewable Electric, LLC 21.09.08 b c utility service entrance PV PV Module Module Pv PV O O Module Module O • ~ E PV PV OD x0 T OH OI Module Module Key PV PV Module Module C Key O A. PV ARRAY B. Conduit Run C. DC Disconnect D. inverter E. AC Disconnect PV PV F. Production Meter I - GutaayDisconnect Module Module H Main Load Center PV _ PV I Utility Meter Module Module PV • PV Module Module 1. The utility voltage at the main panel is single phase 120/240. 2. The PV system is backfed on the supply side of the main service. 3. The inverters have an internal DC/AC disconnect and ground fault protection. 4. The AC utility disconnect is a 60 amp 240 volt Square D DU221 RB. 5. The inverters are a SMA 6000US and a SMA 4000Us. The inverters are Listed to UL-1741. 6. PV array is made up of Sanyo 200 BA19 modules, UL 1703 Listed. 7. PV array contains 24 modules - 4 series strings of 6 modules on SMA 5000 US; 8. PV array contains 21 modules in 3 series strings of7 modules on SMA4000US. 9. 1 inch EMT/FMC conduitwith 12 # 12 AWG Type THWN - 2 and a # 8 grounding conductor 10. NEC Array Open Circuit Voltage = 515 Volts (SB 5000US)/ 595 Volts (SB 4000US) 11. Max Short Circuit Array Current= 26 Amps (SB 5000US)/ Amps 21(SB 4000US) 12. Negative Pole of PV array referenced to ground at the inverter. 13. The DC Disconnect is rated 60 amp 600 volt Waldo Renewable Electric, LLC LABEL One Line Drawing, Grid Tied PV System DATE FULL FILENAME 09.20.2008 Frechette