Loading...
HomeMy WebLinkAboutDeck Field Inspection Notice Town of Montville Building Department May 5, 2008 Address: 2 Allison's Way Job Description: Deck Permit Number(s): B2007-0563 Permit Date: September 26, 2007 Not Approved Approval INSPECTION Date: Deficiencies Special Date Conditions Piers • Pinned both 10/01/07 CC piers Framing • 1112107 DJ Final inspection for 11/2/07 DJ certificate occupancy • Notice: Before a certificate of occupancy can be issued, a C/O signoff sheet must be completed and returned to the Building Department. Signoff sheet are available in the Building Department. Rev. Date: 1/18/06 Page 1 of 1 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: 82007-0563 Date: 26-Sep-07 Map/Lot: 035/009-007 Owner ID: 50000 Project Location: 2 ALLISON'S WAY Unit: Job Description: Redeck Existing Deck, Add Additional Deck Owner Name: Mark A and Dana F Varley Tenant Name: Careof: 2 Allison's Way Oakdale CT 06370- Telephone: (860)889-2096 Contractor Name: Mary & Bob OttersenTelephone: (860)388-2228 DBA: American Deck Lic/Reg Type: HIC Lic/Reg No: 584709 125 Ingham Hill Road_ Exp Date: 30-Nov-07 Old Saybrook CT 06475- Construgin, Value Permit Fees Construction Information Building Value: $1,567.00 Building Fee: $16.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: ~~$0.00 Mechanical Fee: $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $1,567.00 Penalty Fee: $0.00 Permit Code: R10 C of 0 Fee: $10.00 Comments: Plan Review Fee: $1.60 State Ed Fee: $0.25 Total Fee Paid: $27.85 It shall be the owners reosonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING, MECHANICAL, ELECTRICAL PERMIT INSPECTIONS J Footing - Prior to pouring concrete R Plumbing and leak test d Deck Piers R Electrical Backfill - Footing drains and waterproofing Elec Trench - with conduit installed Concrete Slab - Prior to pouring concrete Pool Bonding Anchor Bolts - with sill plate and prior to floor framing Electrical Service CRS No: 0 V Framing R HVAC Masonry Fireplace Throat or Chimney Thimble Gas Piping and leak test Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION Insulation rtifi e of Ap val ert' cat Occupancy Building Official's Approval: _zr Town of Montville Building Departmerrt ` Residential Accessory Structure Plan Review Form Date. y Z Z& 7 Job Address: y "r 6i L C~c Job Description: r C z' y 's Your permit application is being rejected for the items checked off or oommented on. The required information must submitted for review (two sets are required) (C.G.S. 29-252a.) This list is offered as a guideline only. R is not meant to be all-inclusive for every permit application, nor is it meant to take the place of the State Building Code. SUPYOYCMG DOCUMENTATION SITE PLAN Permit appoceiannot cornpleted Plans required permit fee due T _ Plans do riot match the building plans Permit fee to be calculated Finish floor devatim not indicated worker's affidavit or worker's comp. certificate to be submitted Distance from the property s to the stricture not identified copy of contractor's registration or license Structure dimensions not provided Construdiom permit sign-off sheet required with appropriate approvals, it shall Eidsting and proposed cont«us ere not provided or insufficient be the licanR s responsibility to obtain the required signatures 'Footing drain discharge not identified Affidavitrequited from the holder of tlw tegistratiao err licence authDriaag you TJUIWes not ded (electrical hone, cable. sewer, water, to 1 fora permit withtheirinformation Delineation of flood hazard areas and design flood elevation is required per Provide supporting documentation to show compliance with the 2003 IECC section RI06A.3 (www&p!g: vcc des.eov) OR Private sewage disposal system to be identified along with all technical and soil • Ono- and Two-Family Dwellings with :5 151A glazing area to conform to the data as per section R306.2.1 requirements of section N1102.1 Grading is to dapt awe from the building, 'de more detailed information • Townhouses with < 259% glazing area to conform to the req%iraments of Plan submitted is not the same plan that has been approved by the Zoning sectionN1102.1 artmemand/orHWth Department Two sets of construction documents required, this includes all engineering Retaining wall - construction documents required calculations and all other documentation 106.1 Retaining wan documents required to be stamped and signed by a Coimecticut Documents we copyright protcctcd, provide original plans or a letter from the Registered Professional Engineer desi authorizing the duplication of the lens Freid set of the approved construction documents arc required to be picked up FOUNDATION from our effica and mostbe available on site during all i ctSams No plans submitted or insufficient information construction documents shall be of sulMcient clarity to indicate the location. Dimensions required nature and extent of the work o ed as per section R106.1.1 Wall thickness not identified construction documents do not match the orientation of the structure on the Footing size not identified site plan Frost protection not identified or is insufficient column type, size, spacing not identified or insufficient WIND LI1 MATIONS w details not provided or insufficient Submit supporting data to show conformance with the wind limitations (3 Pia type, size and anchor details net provided or innflicient second gust (11) 110 mph) ffoundationplanrequimd Design publication needs to be identified (WFCM, chapter 3; WFCM, chapter crawl ace ventilation. location, type and size not provided w insufficient 2; ASCE 7-20M-. SSTD10-99 Crawl ace access, location and size not provided or insufficient Documents requited to be stamped and signed by a CT registered Professional EnAincer' WINDOWS & DOORS Doenme +ts must be designed to either Door sizes not identified • Wood Frame Construction Manual, 2002 edition Window size & type not identified • ASCE 7 -2002 edition Window header size not identified or insufficient • SSTD 10 -1999 edition Door header size not identified or insufficient Do~•'* t~ required to be stamped and signed by a CT registered Professional Engineer if based on ASCE 7-02 or WFCM chapter 2 GARAGE and CARPORTS Shcarwalls not identified on the construction documents or are insufficient No plan snbnriited or insufficient information provided Shearwall calculations Teguimd Building section required Ridge cononction not identified or insufficient Opening protuhon between the garage and residence is not identified or Rom'-to-wall connection not identified or insufficient insufficient per section R309.1 wall-to-wall comnection not identified or insufficient Separation between the garage and the residence is not identified or insufficient Wall-to-sill connection not identified or insufficient section R309.2 Provide engmeering data for the piers to resist gravity, lateral, shear eruct uplif t loads, stamped and signed a CT licensed design professional ELEVATIONS. Hold-down devices, location and type not identified or insufficient No plans submitted or insufficient information Foundation anchor spacing not identified or insiffcient Plans do not match the floor plans Construction documents do not match the enginnexing data submitted Finish de not identified err does mot match the site an Cold formed steel flaming shall be designed in accordance with COFS/PM- Building " beigWs not identified 2001 edition Dimension height of chimney Roof not identified 9L=*ed9tiay 4, 2007 Town of Montville ] ""ding Department STAIRS SEEDS ct shown Structure has an area of more than 400 square feet - frost protection is ei not identified or insufficient required. Provide details 403.7.4.7 depth not identified or insufficient Ewe height is greater than 10 fed - firost protection is required, provide details xvqtjircd for closed riser stairs (8403.2.4.1 ~nmg can not allow the passage of a C here Ground anchrns are required de if'ounation and details r stair- detailed plans stair-detailed lane required POOLSMOT TUBS ndth to be minimum of 36" abovethtraquirod handrail ha Provide irifbrmation and details for barrier ril detail not provided or insufficient detail Gate can not swmg out over stairs atl detail not provided or insufficient detail Gate required to swing away from the pool area )DID height not identified or insufficient Sukwall support brackets required to be protected by a harrier, provide Wing required at the bottom ofthe stairs information and details OW required at the top of the stairs Gates to self-cl and self-latching aotedion required, Prowde details and connections Doors fivm residence required to be alarmed OR sff-dosing' sclf4atcbmg Pool pump receptacle dimension fIom the pool wall is regmred - show location FRAAMG an an ze and spacing not provided or insufficient General purpose receptacle required (min. 108, max 20 ft from pool) - show ing type not provided at insufficient location an the plan erpared joists, beams and openings Arking typo not identified or unclear partitions not provided or indicated Wiring method not identified or unclear direction not indicated or unclear Burial depth not identified or unclear an & size not provided or insufficient not identified or unclear mm, size & spacing ' not provided Li fixtures-manufacturers install ation instructions required oovcr-~spannmd Electrical plan required for pool vet armed e design data for all unaligned wall and floor hearing points FLOOWRESISTANT CONSTRUCTION 23 Dads not identified on beam data Documentation required to be submitted for the connection, anchored to resist less than 7 r to grade to be pressure treated or decay resistant flotation, colla or anent'--' movement ream - must be stamped and signed by a Connecticut Professional Delineation of flood hazard areas, floodway boundaries, and flood zones and Cr the flood design elevation to be identified on the site plan 106.13 data Elevation of the proposed lowest floor, including baseIDcr t; in areas nil'shallow data flooding (AO zones), the bei& of the proposed lowest floor, including _ e n i-ring required t loads not provided or insufficient basement, above the adaceathighest grade shall be identified R (R]06.1-3) Electrical systems, equipment and component; and heating ventilation, air oning and plumbing appliances, plumbing futures, dud systems, and DECKS / PORCHES conditi action documents required other service equipment shall be located at or above the design flood elevation sions required direction not indicated ELECTRICAL INFORMATION qmn & size not provided or insufficient Plans required showing panel locabors, GFCI, switches, lights and receptacle ran, size & spacing not provided locations over armed Panel location not identified 7ver-s anned laccmptaclc locations net identified or insutfiricnL - show attachmoot and flashing detail GFCI receptacle locations not identified or insufficient m spacing not indicated Lights and switches not identified or insufficient of deck above adjacent finished grade not provided Location of time clock not identified etiens not identified or insufficient to not match site plan FUEL GAS INFORMATION LP Cm tank size: and location not identified on the plans Trench detail not provided or insufficient Piping ddiagram not submitted or insufficient .r ~K~ t aVrr 70 kq r Pro GA,-i"~~ ation reviewed Iry: Demon D. Vesey H David M Jensen Charles Corell Building Official Deputy Building Official Building Inspector 2007 Town of Montville ' Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Fact 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 1bb7 Type of Work c upancy Type Permit Type IjbNew Construction Single Family ff-Building ❑ Addition ❑ Two-Family ❑ Plumbing SrAfteration ❑ Townhouse ❑ Mechanical ❑ Accessory Structure 0 Electrical CRS#: Job Address: y f-~'I) i~,>Oyn (A-► (Number) (Street) (Unit) Job Description: & ~ v~ aJA VW Owner: VA, YY1 c-f- A- + Address: 9- 'j 4441(56Y) f v City: State: Zip Code: Telephone: 9 Contractor: Al IVA 4? rC C DBA: W( W' Ii 0 Address: At t f f City: State: Zip Code: b `7 J Telephone: tense Type: License No.: y 7 Expiration Date:_ ~0 f a ° ..rte 1 hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the Proposed work is authorized by the owner in flee and that I am authorized to make application for a permit for such work as described above. By checking this box, I will follow the requirements of the 2005 NEC as the aftemative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner /Agent Signature: - Date: / l I ~l /0 Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of O Fee: co Plan Review Fee: State Ed Fee: e) o a Total Fee: 4tviwd- August 23, 2007 Residential Permit Requirements Checklist list is to be used as a guide only and is not all-inclusive; additional information may required for your particular act. Two complete sets of construction documents required. Not ided Item Not Applicable lortin Documentation Provided Ai likable Item Completed, signed and dated Building Permit Building Section & Details A lication FloDr-tao-floor heights Completed worker's compensation affidavit for Material type, size andspacing property owners or sole proprietors or copy of Stair details (rise, run, treads, nosing, width, workers compensation insurance headroom Co of Contractor Registration. or license Handrail details Construction permit sign-off sheet signed by all Guardrail details d rtments Roof ventilation Documentation showing compliance with the Framing Plans Energy Conservation Code Design loads - for floors, ceilings, roofs ypW.ener codes. ov or Chapter 11 Bearing rtitions identified on the an Street address of project on all drawings and documents Direction of framing Spans, beam Limitations Criteria wood species and grade Framed o enin s Documentation showing compliance with the Wall framing size andspacing identified requirements for construction in 110 mph wind Sheathing and thickness zone Window and door header sizes Design publication identified; WFCM-2001, chapter 2; WFCM-2001, chapter 3; SSTD 10-99; Decks material, size, spacing ASCE 7-02, AISI, COFSIPM Engineering data for engineered lumber (LVUs and Hoists Framing n for engineered lumber Plan Engineering data for steel beams, signed and Property lines sealed b a CT registered design professional Distance from property to structure Engineering data for trusses, signed and sealed Structure dimensions a CT registered Professional Engineer Driveway Note: Unusual structural conditions may require Topography (existing and proposed) that additional engineering back u be submitted Footing drain inverts, outlet and separation Chimne & Fireplaces Proposed utilities Clearances to combustible materials Wetlands and flood zone limits and elevation Manufactures data for metal flues ticsystem shown and located on the plan Exterior fresh air source for fireplaces Well and piping shown and located on the an Flue sizes rldation Information Manufacturers data and installation instructions Assumed soil bearing pressure for metal fireplaces, Dimensions Electrical Information Wail thickness Panel tation(s) with main size Footing sizes Meter socket location Frost rotection GFCI outl et locations Foundation anchor type, size, locations Smoke detector locations Window and door sizes and locations hts and switches Hatchways Mechanical Information Columns Dryer vent Drainage details Bathroom exhaust ventilation (natural or Waterproofing details mechanics and size Crawlspace ventilation size and location Hued exhaust Crawlspace access size and location Type of heat oil, electric, as Concrete strengths Heating, ventilation, and air conditioning plant or Plan Information location Dimensions Oil tank size, location, and piping Door and window sizes egress window LP-Gas tank location, size and piping Glazing in hazardous locations Combustion air requirements Garage/dwelling opening protection Manufacturers data for equipment Garage/dwelling separation Heat I= Heat gain calculations kitchen layout Plumbin Information Bathroom layouts, tub sizes in gallons, space Building trap location if on municipal sewer clearances Sewer location Indicate use of all rooms Domestic water location Stair location Water heater size, type, and location Attic access location and size Manufacturers data for whirlpools, comer tubs, & Square footage for each habitable level of the tamer tubs sbucture Required light and ventilation for each habitable room rations Type of siding Roofing Other finishes Finish grades Building heights Height of chimney above roof Roof itch Town of Montville Building Department File Receipt Date: 18-Sep-07 Receipt No: 2777 Received From: American Deck Job Address: 2 Allison Way Fees Collected State Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $27.85 Check: $0.25 Check No: 10508 Short/Over: $0.00 Construction Value: ~$1,56 0 Demolition Value- $0.00 Received By Vernon D Vesey II Ao- ess: ITEM QTY $1UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 114.17 $ - $ - Basement, Finished SF $ 20.87 $ - $ - Basement, Unfinished SF $ 11.28 $ - $ - Crew! Sapce SF $ 8.46 $ - Interior Renovations SF $ 31.90 $ - $ - $ - MANUFACTURED HOMES Ground Anchors SF $ 5.86 $ - $ - $ - Basement SF $ 11.28 $ - - $ - $ - Crawl Space SF $ 8.46 $ - $ - $ - AMENITIES Kitchen FA $ - $ - $ - Full Bathroom EA $ - $ - Half-Bathroom EA, $ - $ - GARAGE Attached SF $ 49.41 $ - $ Detached SF $ 63.21 $ - $ - Under SF $ 9.12 $ - $ - Carport SF $ 18.08 $ - MECHANICAL Wamr-Air Y Y/N $ - Hot Water <.SN Y/N $ - Electric 'N - Y/N $ - Air Conditioning N YIN $ - ELECTRICAL SERVICE Upgrade Amps $ - Overhead, new Amps $ - Underground, new Amps $ Subpenel FA $ 545.00 $ - Gen Set EA $ 3,500.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 5,907.00 $ - Masonry w/l fireplace EA $ 6,451.50 $ - Masonry w/2 fireplaces EA $ 10,087.00 $ - Wood Stove, free standing PA $ 2,447.50 $ - Wood stove insert EA $ 1,690.70 $ - DECKS, PORCHES, SUNROOMS Deck '.40 SF $ 39.16 $ 1,566.40 Porch SF $ 135.80 $ - Sunroom SF $ 160.82 $ - $ - POOLS & HOT TUBS Hot Tub FA $ 7,287.50 $ - $ - Inground Pool IA $ 19,430.40 $ - $ - Above Ground Round FA $ 4,635.88 $ - $ - Above Ground Oval FA $ 5,472.50 $ - $ - Pool Heater EA $ 8,167.50 $ - Inflatable Type Pool FA $ 1,542.42 $ - SHEDS w/o electrical SF $ 16.50 $ - w/electrical SF $ 18.50 $ - $ - RENOVATIONS Roofing, Overlay SF $ 3.38 $ - Roofing, Strip & reroof SF $ 3.76 $ - Roof Sheathing SF $ 1.19 $ - Siding SF $ 2.30 $ Windows EA $ 423.50 $ - Skylights EA $ 955.54 $ - Doors, Exterior EA $ 401.50 $ - Oil Tank, 275 Gallon FA $ - Oil Tank, 550 Gallon EA $ - MISCELLANEOUS CALCULATIONS TOTALS $ 1,566.40 $ - $ - $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ 1,567.00 $ 16.00 Plumbing Y $ - $ - Mechanical YY $ $ - Electrical Y $ $ - Working before Permit Issuance $ - Certificate of Occupancy Fee $ 10.00 Plan Review Fee $ 1.60 State Education Fee $ 0.25 TOTALS $ 1,567.00 $ 27.85 Figures are based on the 2006 RS Means Residential Cost Data State of Connecticut Workers' Compensation Commission - Please TYPE or PRINT IN INK oai Proof of Workers' Compensation Coverage when Applying for a Building Permit for the General Contractor or Principal Employ who has chosen to be EXCLUDED from Coverage Applicant for Building Permit Name of Applicant for Building Permiitt , Property located at 1542" JA (d QJ in the City / Town of &I V 0 If you are the General Contractor or Principal Employer of a business doing work on the site of the construction project at the above-named property and you have properly excluddd yourself from workers' compensation coverage by filing one of the appropriate forms listed below with the Workers' Compensation Commission, complete this form and, if applicable, sign the Affidavit below in the presence of a Notary Public or a Commissioner of the Superior Court. FIRST - CHECK ONE (1) BOX: am: ❑ an Officer of a Corporation 110-a Manager or Member of an LLC ❑ a Partner in a Business THEN - CHECK ONE (1) BOX, provide the appropriate information, and sign the Affidavit below: I have filed the following certificate with the Workers' Compensation Commission: Form 6B (for an Officer of a Corporation, a Manager of an LLC, or a Member of a Multiple-Member LLC) ❑ Form 613-1 (for a Partner in a Business) AFFIDAVIT I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor, subcontractor, or other worker before he or she does work on the site of the construction project at the above-named property in accordance with Section 31-286b of the Workers' Compensation Act Signature of GENERAL CONTRACTOR or PRINCIPAL EMQLO~YEER Applicant Name of Business-if applicable Federal Employer ID# (FEIN}-if applicable My JV02' J p, ROBE N'pfpfRESQC'j~31,20r2 Subscribed and swom to before me this o day of 200_ . Signature of Notary Public/ Commissioner of the Superior Cou a C`, C Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL Property Address 6-6t,61 ox decic Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Department Permit Issuance Approval Approval Tax Collector guired for all permits Comments: ® WPCA, Administrative Required for properties on sewer Comments: ❑ WPCA, Operations When Required by WPCA Comments: Planning & Zoning f2!&444 03 Gl r1 i I ? J~uired for all ermlts Health Department 1Z H lu-ired for properties with septic sstems - Not re uired for Plumbin Ele rival Mechani I oofin Sidin Windows & Doors Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Comments: ❑ State Dept. of Transportation Required for Structures over 100.000 sq. ft. or with more than 200 paddoo spaces - Official copy of STC Certificate of Operation required - per CGS 14-311 Comments: ' I U, Fire Marsha *Re uired for all ermjts Comments: ftvised.August S, 2005 ; I I : , rz) r i I I I i ' ~ I I~~ ' : I t i~ i ~ i I ~I I l l~ i l i I ! I ' ! I I I I , I r I 1 1 i - t i J I I : I r I f - I j , I r~ F -T) e to 1 t L2~ (~,,E i4.C)C ~•^T 2._i6 ~t t E..- SEA ADD Z -10 PLlz A-TTAC-W-2,,, -D~+AtL-LA1,7-) t-M O L} A'~ LLe- 41 AL~t W) -z V bkt-?, . z o F I'D n Q~ "Oil . ~ CMG SAY, )GG Q 70~ c vi 131 0 FINISH GRADE 0 0 B ~ 0 O 0 0 ~ F O 0 0 j © 0 a G U Z Y E Q U: i A. 6X6 PRESSURE TREATED POSTC0,40 6402-~>~~" W B. COMPACTED FILL C. POST BASE PER PLAN D. CONCRETE FOOTING TYPICAL E. WIDTH OF FOOTING PER PLAN/LOCAL CODE_ ` FOOTING/ COLUMN F. LOCAL FROST LINE '-A Z' SECTION G. HEIGHT OF FOOTING PER PLAN/LOCAL CODE --z 5~zr L A.2 E D A B I.I- I I.i N a . w . o 4J V B a U Z Y U . •v w A. 2X10 PRESSURE TREATED B. 6X6 PRESSURE TREATED C. 2=16" SHEAR BLOCK W/ DRESSED EDGE TYP. EACH SIDE STANDARD D. 1/2" X10" CARRIAGE BOLTS POST TO E. 2X8 SPACER BLOCKS 24" O.C. Bin POST CAP VINYL CROSS MEMBER WITH ALUMINUM INTERNAL CROSS MEMBER _ 2X2 VINYL BALUSTERS d' M 5" O.C. PT 4X4 POST WITH VINYL SLEEVE VINYL CROSS MEMBER WITH ALUMINUM VINYL POST SKIRT INTERNAL CROSS MEMBER i 2 3/4" SPACE (3" MAX) -d- TRIM BOARD 2X8 FRAME 5" LEDGERLOKS RAIL BLOCK Vinyl Rail Ali construction must comply with local building codes and standards. Unless otherwise specified Dotal: Rail: Vinyl Rail Detail Scale: NTS on contrad INS drawing must be submitted for review and approval by the local building code Sheet authority. This detail is for general information and guidance only, and American Deck Inc. specifically disdaims any liability for the use of INS detail and for the architecture, design, G-10 American Deck L engineering or xorkmanship of any project. American Deck Inc. is not liable for any archflectural, Designer: , Inc. Date: 8/6/2007 engineering, structural, design or workmansNp issues related to the existing structure. Unless otherwise specified the live load capadty of this design is not to exceed: F40 IbS/ft2 Of 16 5~~ Cp ter- -t i Rail Blocking for Full Exterior Mount Wood Posts i 4x4x7" Block 4x4 Full Post 5" LedgerLok through - 2x8/1 Block interior block into post 2x8/10xT Block (2) 5" LedgerLok lag bolts per post 2x8/10 Block Note: Double framing eliminates the need for the additional parallel blocking. Carvers Project Ali construction must comply with local building codes and standards. Unless otherwise specitled Owner' 90 Anthony Road Scale: 30 on contract this drawing must be submitted for review and approval by the local building code Sheet North Stonington, CT authority. This detail is for general information and guidance only, and American Deck Inc. specifically disclaims arty liability for the use of this detail and for the architecture, design, Designer: American Deck. LLC. engineedng or workmanship of any project. American Deck Inc. Is not Rabb for any architectural, Bob Otbrsen Date: 7/31/2007 ergineerng, structural, design or workmanship issues related to the existing structure. 1251rghern Hill Road Old Saybrook, CT 06475 Unless otherwise specified the live load capacity of this design is not to exceed: F40 lbS/ft2 Of 3 Cell: WO-WS-2228 St-1~L-T ~ ~ F