HomeMy WebLinkAboutReplace Pellet Stove with Woodstove 2017 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860)848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2017-0032 Date: 25-Jan-17 Map/Lot: 032/007-000 Owner ID: 5833000 Project Location: 376 RAYMOND HILL ROAD Unit: Job Description: Replace Existing Pellet Stove with Woodstove Owner Nam Leland W and Juliet L Boltz Tenant Name N/A Careof: 376 Raymond Hill Road Uncasville CT - 06382- Telephone: (860)848-747.6 ------------- Applicant Name Property Owner Telephone: DBA: Lic/Reg Type Lic/Reg N 0 Exp Date: Construction Value Permit Fees Construction Information Building Value: $3,390.00 Building Fee: $48.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Valu $0.00 Mechanical Fe $0.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type IRC Total Value: $3,390.00 Penalty Fee: $0.00 Permit Code: R4 C of 0 Fee: $0.00 Comment Plan Review Fe $0.00 State Ed Fee: $0.88 Total Fee Paid: $48.88 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test O Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete 0 Pool Bonding O Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: 0 ❑ Framing 0 R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION 0 Insulation 0 Certificate of Approval ❑ Certificate of Occupancy Building Official's Approval: u` _ Town or Montvme Building Department 310 Norwich-New London Tpke. Tel.860-848-3030, Ext 382 Uncasville, CT 06382 Fax.860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 6avj1 -oa3c; Type of Work Occupancy Type Permit Type D New Construction 0 Single Family 0 Builfng RAdditiontwo-Farnily 0 Plumbing rAlteration 0 Townhouse �Mechanical 0 Accessory Structure 0 Electrical CRSS: Property Address: 376 P yi r i / ,lJA ' (Nr) - (Street) (Unit) Job Description: 1 i1gce Q_)/1 i te-44 1, // L 71>l# r / / Q 11<-0Y1 l/.' 9 • - - / /%1i44 by Owner: Cl,e_ Address: / 7!A 6 � / // U i2 City: ii cq',V I/4 ` State: GT— Tp Code:&'/3 u Z Telephone( )< -1l-7jo Applicant: SPLs-rt-L ct9 CVO/ze ---- DBA: Address: City State: Zip Code: Telephone( ) Contractors-Complete the Following: License Type: License No.: Expiration Date: I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. j By checking this box,I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner/Agent Signature: '' / Date: 1/Z! /7 Construction Value Permit Fees Building Value: Building Fee: %-(�U Plumbing Value: Plumbing Fee: Mechanical Value: 4,b4%) Mechanical Fee: Electrical Value: Electrical Fee: d1 Total Value: +zt 3L 90 Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: Total Fee: • $anis rf August 23,2037 Town of Montville Building Department File Receipt Date: 74-tan-17 ReceiptNo: 12014 Received From: Job Address: 376 Raymond Hill Road Tewn Feac reil�cted _State of Cpnnectjgj Fees r u ectecL Bldg Cash: X48 88 State Cash: 0 88 Bldg Check: 30 00 State Check: 0 00 Bldg Credit: �0 00 State Credit: 0 nn Fire Cash: 0 00 Fire Check: _gum_ Fire Credit: 0 00 Construction Value: CheckNo: Demolition value: Received By: Carmen Kneeland Address: 376 Raymond Hill Road ITEM QTY $/UNIT TOTAL BUILDING AREA Building Plumbing Mechanical Electrical Basement,Finished SF $ 41.96 $ _ $ Interior Renovations SF $ 36.09 $ _ $ - - AMENITIES Kitchen EA Full Bathroom EA $ $ $ Half-Bathroom EA $_ $ GARAGE Detached SF $ 71.53 $ _ MECHANICAL Warm-Air n Y/N $ _ Hot Water n Y/N $ Electric n Y/N Air Conditioning n Y/N $ $ ELECTRICAL SERVICE Upgrade Amps $ Subpanel EA $ 699.00 Gen Set EA $ 3,850.00 $$ SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace BA $ 6,497.70 $ Masonry w/lfireplace BA $ 7,096.65 $ Masonry w/2 fireplaces EA $ 11,095.70 $ _ Wood Stove,free standing EA $ 2,692.25 $ _ Wood stove insert EA $ 1,859.77 $ DECKS,PORCHES,SUNROOMS Deck SF $ 44.07 $ _ Porch SF $ 149.38 $ Sunroom SF $ 176.90 $ _ $ POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - Inground Pool EA $ 31,550.00 $ $ $ Above Ground Round EA $ 6,299.46 $ _ Above Ground Oval EA $ 7,019.75 $ _ $ $ Pool Heater EA $ 8,984.25 $ $ Inflatable Type Pool EA $ 1,200.00 $ $ SHEDS w/o electrical SF $ 25.55 $ w/electrical SF $ 26.85 $ _ $ RENOVATIONS Roofing,Overlay SF $ 3.50 $ Roofing,Strip&reroof SF $ 4.50 $ Roof Sheathing SF $ 1.51 $ Siding SF $ 6.75 $ - Windows EA $ 550.00 $ _ Skylights EA $ 1,051.10 $ Doors,Exterior BA $ 601.50 $ Oil Tank,275 Gallon EA $ Oil Tank,550 Gallon EA $ _ MISCELLANEOUS CALCULATIONS $ 3,390.00 TOTALS $ 3,390.00 $ - PERMIT FEE CALCULATIONS Building Construction Value Fee $ 3,390.00 $ 48.00 Plumbing y $ $ Mechanical y $ $ Electrical y $ $ Working before Permit Issuance $ Certificate of Occupancy Fee $ Plan Review Fee $ State Education Fee $ 0.88 TOTALS $ 3,390.00 $ 48.88 Figures are based on the 2006 RS Means Residential Cost Data Fireside Supply, Inc. 33 East St Hebron CT 06248 Phone 860-228-1383 Fax 860-228-3044 www.firesidesupply.net Date: 1/TZ1/7 • Customer's Name _ l�� o TQC lie &, /Z--Z-- Street LLQStreet Address �7Gyf.z'AJJ zy Town Cc. vi1le C7- Zip Code Oleg Home Phone Scan— 24-s—74-740. L-62_ &a/�� has been authorized to apply for a permit(s) for Fireside Supply, Inc.,to perform work at the above address and use our Home Improvement registration and Heating, Piping& Cooling registration numbers as required by law to obtain said permit. - Scheduling of Final Inspection with the Building Department is the RESPONSIBILTY of the HOMEOWNER, Sing„ , 111111.11 0 ,44/011001k � quinio I `-de Supply, Inc. STATE OF CONNECTICUT „c,'1x7ireNrueco\sc.u,:x,>xurec�,o.\ STATE OF CONNECTICUT HOME IMPROVEMENT CONTRACTOR hrn 4,zri,1 rue ro\s, 111:R ,>xorecr,o FIRESIDE SUPPLY INC HEATING,PIPING&COOLING LIMITED CONTRACTOR B 33 EAST ST HEBRON,33B CT 06248 f JOHN TARQUINIO FIRESIDE SUPPLY INC FIRESID UPPLY INC 33b EAST ST S LIC./R c14.a. EFFECTIVE EXPIRES HEBRON,CT 06248-1308 HIC.05 849 _ 01/2016 11/30/2017 LIC./REG NO. EFFECTIVE EXPIRES 3TG.0398 1-HPG1 09/01/2016 08/31/2017 SIG,ED i SIG V, PRODUCT SPECIFICATIONS R RESOLUTE ACCLAIM NON-CATALYTIC ` El�ML� `ASTI"`' WOOD STOVE :;a i 25'/z" (648 mm) • r F 1, �,i 27'h" G������ 3, (699 mm) " j II a I ',. r µ • / (152 mm) 1426" •I (660 mm) ACTUAL DIMENSIONS Unit Depth:23" (584 mm)(flue collar in top exit position) Unit Height:27 1/2" (699 mm) Unit Width:26" (660 mm) t 25" (635 mm) • TECHNICAL INFORMATION 21'/2' Log Length: up to 16" (406 mm) (546 mm)—' nommimmBurn Time: up to 9 hours �t h Heating Capacity: up to 1,600 sq.ft.(149 m2) t Maximum Heat Output: 51,000 BTUs/hr. 1 21W Efficiency Rating: 75% (546 mm) EPA Emissions Rating: 3.4 grams/hr. [1!IiIiI / (Reg.Legs) (635mm) I 191/2' Flue Collar: 6" round, reversible (495 mm) Firebox Volume: 1.7 cubic foot(.04 m3) .;•__________-..„-_- (Short Legs) Clearances(with optional heat shields) Back: 15"(381 mm)(measured to back of stove top) (I, Corner: 15" (381 mm) ,i, Side: 15" (381 mm) I — 19" 1 (483 mm) FIELD INSTALLED ACCESSORIES •Spark screen for open door fire viewing •Available in Classic Black, Biscuit, Majolica Brown, Ebony Black and Bordeaux 123/4" • Matching enamel pipe in three standard colors I`(324 mm) • Rear and bottom heat shields •Warming shelves with mitten racks t _•Outside air adaptor19'/z" • Stove surface thermometer (495 mm) •Short legs 23"(584 mm) 11Hi i •1;;):.-.- ---'-- A Brand of Monessen Hearth Systems Co. 149 Cleveland Drive, Paris, Kentucky 40361 www.vermontcastings.com SEE BACK FOR MORE INFORMATION a ' x 3r. r i ' i 1' '',i .,„ „8, It It \ t, ,, 1 1 . pt / 0 ,..,.......,,,,.., - / ,.. i 0.,,. "44*, 11.11111fte,_ r� .: -:4 4, /0 ` / 140/1,; a • pi a:1 f7 L IWOOD PELLET STOVE TO BE REPLACED I EXISTING 6" DIA EXTERIOR METAL CHIMNEY • REPLACE THE EXISTING WOOD PELLET STOVE WITH A NEW VERMONT CASTINGS RESOLUTE ACCLAIM WOOD STOVE • CONNECT THE NEW STOVE TO EXISTING 6" DIA THIMBLE USING NEW DOUBLE WALL 6" DIA CHIMNEY CONNECTOR • CONNECT TO EXISTING OUTSIDE AIR SUPPLY • THE NEW STOVE WILL OCCUPY APPROXIMATELY THE SAME SPACE AS THE EXISTING STOVE • THE NEW STOVE WILL HAVE A BOTTOM HEAT SHIELD TO PROTECT THE HEARTH FROM HIGH TEMPERATURE • THE EXISTING CERAMIC TILE HEARTH IS SPARK AND EMBER PROOF, BUT WE ARE ADDING A NEW 42" WIDE HEARTH BOARD UNDER THE STOVE FOR ADDITIONAL PROTECTION I, u- PRODUCT SPECIFICATIONS •#. RESOLUTE ACCLAIM NON-CATALYTIC WOOD EFkMON STOVEASTING (CONTINUED) STOVE CLEARANCES UNPROTECTED SURFACE CORNER PROTECTED SURFACE PARALLEL INSTALLATION INSTALLATION CORNER Side A PARALLEL INSTALLATION INSTALLATION ( ) Rear(8) Corner(C) Side(D) Rear(E) Corner(F) No heat shields 15" 24" 15" 8" 13" (610 mm) (381 mm) (203 mm) 8" (381 mm) (330 mm) (203 mm) Top exit, rear heat 15" 24" shield only' (381 mm) 15 8" 13" (610 mm) (381 mm) (203 mm) 8 (330 mm) (203 mm) Rear exit, rear heat 15" 10" shield only N/A 8" 7" (381 mm) (254 mm) N/A (305 mm) (180 mm) Top exit, rear heat 15" 15" shield,single wall (381 mm) 15" 8" 9" pipe with connector shields'.2 (381 mm) (381 mm) (203 mm) (229 mm) 8 (203 mm) Top exit, rear heat 15" 17" shield, double wall (381 mm) 15 N/A N/A pipe1.3 (432 mm) (381 mm) N/A ♦I ♦I •I a c pall\+ 4iumi –111% A '–L-NTa'—'"1– '. „,,, „ ,,, __, =_ E ,...--__.---- 01L.1) / . .N\ 0 Stove installed Stove installed Stove installed parallel to wall corner parallel to wall coone installed corner 'When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so that the area behind the flue collar on the stove is protected. 2Chimney connector heat shields must extend exactly 28” (710 mm)above the flue collar of the stove. No shielding can be used on the connector above 28" (710 mm).The unshielded chimney connector above the 28" (710 mm)point will be 14" (360 mm)from an unprotected wall or 8" (203 mm)from a protected wall. `In top exit installations,this clearance requires the use of the rear stove heat shield with the shield insert installed. / 'rE (.- © B *FBA *MAC * * P To avoid personal injury or property damage,the product described by this brochure must be installed,operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes.Contact local building or fire officials about restrictions and installation inspection requirements.All photographs and drawings on this brochure are for illustrative purposes only and are not intended for,nor should they be used as a substitute for the instructions packaged with the unit.Appearance and specifications of the product are subject to change without notice.©2011 Monessen Hearth Systems Co. r x QUOTA TION PAGE:1 FIRESIDE SUPPLY, INC. PHONE#: (860)848-7476 Ext: Home DATE: 1/21/2017 33-8 East Street CELL#: (860)625-5853 ORDER#: 54117 Hebron , CT 06248 ALTPhone#: (860)228-1383 .o P.0 #' CUSTOMER#: 15996 .O.#. CP: John T TERMS: Cash LOCATION: 1 SALES TYPE: Quote STATUS: Active Jt ,/' j 15996 mkt; Lee Boltz 376 Raymond Hill Road Lee Boltz Uncasville, CT 06382 376 Raymond Hill Road Uncasville, CT 06382 ;!.r$,.,,„°=ry 4 :" „ ,,, it, h ia,,�A��//% ' � " *I 4r/ -; '','- „ ;''7s :, ,; > VC 2491 ���������//// x , .. �////�%%%i//;,���%%�%%/'////�� ���%/ Resolute Acclaim NC Wood Stove-Bordeau 1 $2,971.00 $2,971.00 ""' DISCOUNT $2,971.00 floor discount/discountinued model discount 1 $0.00 "" MISCELLANEOUS bottom heat shied ($400.00) ($400.00) 1 $75.00 $75.00 $75.00 DURA6DVL-ADWD Adapter/Damper Section 1 $69.80 DURA6DVL-46TA Telescoping Length 29"-46" $73.00 $69.80 DURA6DVL-E90 1 $173.00 $173.00 $173.00 90 Double-Wall Black Elbow 1 $112.60 DURA6DVL-ADT DVUDuraBlack Chimney Adapter/with trim $110.50 $160.50 1 DURA6DVL-12 $60.50 $60.50 $60.50 12" Double-Wall Black Pipe 1 $57.60 DURA6DVL-12ADJ 12"Double-Wall Adjustable Black Pipe $71.60 $71.60 1 $71.60 $71' MISCELLANEOUS hearth board from stock 42" USED BRICK .00 443.00 """ ""* DISCOUNT INSTOCK DISCOUNT 1 $443.00 $443.00 $443.00 1 $0.00 """" INSTALLWS DELIVERY& INSTALL INTO EXISTING ($10 5.0) ($100.00) CHIMNEY 1 $695.00 $695.00 $6955..00 "'"" DISCOUNT DISCOUNT FOR TRADE IN STOVE 1 $0.00 ($1,000.00) ($1,000.00) CUSTOMERS ARE RESPONSIBLE FOR ALL PERMITS & INSPECTIONS CT License#HIC0550849 & HTG0398151-HPG1 Deposits and or Down Payments are NON-REFUNDABLE. Fuel is Non-Returnable or Refundable. Prices are subject to change without notice. ALL Pricing is Contingent on Verification via a Site Inspection. All Discounted Sales are Final- No Refunds or Returns. Please Allow four to six weeks for all Special Orders Payment is due in full when services are rendered. SUBTOTAL: $3,229.10 TAX: $160.92 ORDER TOTAL: $3,390.02 All items are considered"Special Order"unless otherwise noted.Customers are responsible for all permits and inspections. Allow at least two(2)to four(4)weeks from date of invoice for delivery of all product(s),and or installation. See reverse for terms. Authorized By: Date: Signature: Town of Montville Building Department CONSTRUCTION PERMIT APPROVAL .3-71 Mrrnt h It Propeity Address tticc P� ick- Ve---�, 113 s+z tj Job Description Required Department Approval ' Permit Issuance Approval II t/ Tax Collector ��„ o _ ,fl 7 Comments: Signature/date ® 7 Fire Marshal i4/41 Comments: I L- Signature/date ❑ Planning &Zoning Required for all permits except Signature/date Plumbing,Electrical,Mechanical,Roofing,Siding,Windows&Doors El Health Department Required for properties with private septic or well Signature/date Comments: 0 WPCA, Administrative Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: - ❑ Montville Police Department Required for all permits EXCEPT one and two family residential Signature/date Comments: ❑ Copy of State Dept. of Transportation Certificate Required for Structures over 100,000 sq.ft or with more than 200 parking spaces-Official copy of STC Certificate of Operation required-per CGS 14-311 Signature/date Building Department Final Inspection R23,