Loading...
HomeMy WebLinkAbout1993 - Fire Protection System TOWN OF MONTVILLE \ Building Department 848-7166 APPROVED BUILDING PERMIT OR TRADES PERMIT For 180 Days Permit No: 10903-F Approval Date: 7/16/93 Expiration Date: 1/16/94 Estimated Cost : 11 ,000 . 00 Fees: 88 . 00 PRF: C.O: Owner: VFW Post 10060 Address: 91 Raymond Hill Road Tel : 848-3750 Job Location: 91 Raymond Hill Road Code: 11 Contractor: Visco Inc . Address : 40 Rose St . Tel : 413-734- 6996 Stick Built : Modular Home: Manufactured Home: Commercial : x Addition: Garage: Car Port : Shed: Remodeling: Roofing: Siding: Fireplace: Chimney: Windows : Pool : Demolition: Plumbing: Heating: Electrical : Air Conditioning: Gas : Patio: Porch: Deck: New: x Repair/Replacement : Type of material used/discription: install hood and fire protection system in kitchen Size: Type of Heat : Fireplace: No.of Stories : No. Rooms : Breezeway: No. Baths: Garage: Use: I hereby certify that the proposed work will conform to the Basic Building Code and all other Codes as adopted by the State of Connecticut , and the Town of Montville. /`� / A licant 's S' n t . w"``�'""�-- a/��'az PP �g a ure• .7 / Date: VA/P3 If signed by Contractor, type of license/registration & No: 1 - / J1//02c� Building Official 's Signature: • , ,4, , �!�� �; Date: // Date of Health Dept . Approval : A) Date of Zoning Approval : /"//," THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE BUILDING CODE, SECTION 119.1 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO ANY USE OF THE STRUCTURE. TOWN OF MONTVILLE Building Department Application for a Permit Owner : Vr–T 'PSIS i IQW Address: 9/ j-y/YO/(faL/ Tel : 848-37co Job Location: 94/ R74t41110,3 D 411-1- -et) , Contractor : \/ ISCO CaC . Address: 40 C _S Te1 :5/3- 3c./-E?j6 Stick Built: Modular Home: Manufactured Home: Commercial : Addition: Garage: Car Port: Shed: Remodeling: Roofing: _ Siding: _ Fireplace: _ Chimney: Windows: Pool : — Demolition: Plumbing: _ Heating: _ Electrical : _ Air Conditioning: Gas: Patio: _ Porch: _ Deck: _ Retaining Wall : New: Repair/Replacement: _ Type of Material/job description: Ss, Krr(,4 j 0, AvsT 14.0.1c, cL Size: Type of Heat: Fireplace: No. of Stories: No . Rooms: Breezeway: No . Baths: Garage: Use: 11 FIRE DEFENSE CENTERS HF • 832 SILAS DEANE HWY WETHERSFIELD, CONNECTICUT 06109 CT (203) 296-8888 • MA (413) 737-2353 • FAX (203) 563-2151 Municipality -----404.04-0 o < UNClaSVI LA-Kr- . Job Name Vic--. (A). 110(e) Starting Date 47-.2 l -93 Job Description S.S. V:tT(j44.14 EXHAUST f-/or�Q lit. gag. 3bpt.+fcSTIOn.J ;S TAEMA- . Per Public Act 91-95 Sc This letter authorizes PAUL_, AL.ErN/K to sign the permit as an agent of Fire Defense Center for the above mentioned job and municipality. Applicable License: [Ft 1 ho$ ri. FIRE DEFENSE CENTERS NFPA' 99 Hanmer Street • Hartford, Connecticut 06114 CT (203) 296-8888 • MA (413) 737-2353 • FAX (203). 96-7112 1,-- OEPARTMENr OF PUBLIC SAFETY �•-:,k't.,.: COMMONWEALTH1:.:r'•, - NI A '/ OF 1 1010 COMMONWEALTH AVE V; MASSACHUSETTS ; �STON,MASA•01216 / I • NCL9Sg CHECK OR MONEY ORDER CERT OF REGISTRATION FOR REQUIRED FEE, EXPIRATION DATE OOO .9 FIRE EXTINGtiISHER (C ) 09/01/ 1993i MADE PAYABLE TO R S - TTRICTIONS F' EFFECTIVE DATE LIC-NO. { 4 O9/O1 /1 991 OCC 1 C 9 ••dc.i "'COMMISSIONER OF PUBLIC SAFETY" FIRE DEFENSE CENTER k (DO NOTSENDCASHJ. SS t! HARTFORDUTH I�CTT061C6TREE1 ' /� ' U I�= 1•1?- 2 PHOTO 19MIlING OPR ONLYI FEE: ,� lr� Ll , oC.00 446/aa it NOT VALID UNTIL SIGNED BY LICENSEE AND OFFICIALLY 'f N NAME IN FULL•ABOVE SIGNATURE LINE o•...; .•.a;. HEIGHT: .'.'� r STAMPED -OR •SGNATURE OF THE COWYSSGNER = I 1,7:2)_ •-: DOB M.. (`, : .= •� 00/CO/COLO ' ,a(,,ep. 2‘,. PC NOT C LKCEfwe STUB • ,`.L7. ,tU•: • • rnA DocuMIENT NusT BE•, SIGNATURE OF LICENSEE SIGN NAME IN FULL-AlOOVE SIGNATURE LINE • eta CARRIED ON THE PERSON OF THE HOLDEN WHEN ENGAG I OTHEIIS,;a10HT IHUMW PRINT EO IN IRIS OCCUPATION+ COMMISSIONER 1 • •. COMMONWEALTH -- 1 ....✓ • ' OF i 1010 COMMONWEALTHCAVL _ I -- l MASiAC►wSETrS 160STON,M .02116 IPCLOAJEC. R JY ORDER sen °1 LICENSE EXPIRATION DATE , SPRINKLER CONTRACTOR OCNOyGI JI� 1991D FEE, 10/15/1993 MADE PAYABLE TO RESTRICTION$ EFFECTIVE DATE LIC-NO. NONE t 3(:1 3 ` '•C B;;t ISSI f>�E p F . SAFETY" UtV�>r: .... .�.� 0 10/1S/1991 004487 ) . • i JAMES R SWEENEY i• �Q NOT SEND CASH). • • MO SS 1 016-36-6839 w1 TZ 13 04279E 1.1.010 IB.,.7tINa or%ONLY) FEE: - 50.00 HEIGHT: NOT VALID UNTIL SQNSO BY LCSNOEE AND OFFICIALLY I BIAYPBO•OR•A4$ATURM DR THE COMUANSGNOR DOB. 10/15/i 9461 n U,Qe�u RO NOT DETACK aCENSE__S_Ysl THA UUr.sI, MUMI OE i I STATE OFGONNECTICUT r,AAHIEO GN fin PERK.OF (NONE Of LICENEGE THE HOLDER WHEN ENOAG• 1 I DEPT.OF CONSUMER PROTECTION , whin•RGrIT THUMB 111511 ED IN 1TBS OGCUPATpN,. )31 �oM•aaTalstTl � Ili 0 A- !'� :� BOARD FOR OCC. LIC. +' COMMONWEALTH a .1• . TN A• , :r,._ �• STATE OF CONNECTICUT -OF DEPT.OF CONSUMER PROTECTION . W.. MASSACHUSETTS T F WO 012,116 '^ BOARD FOR OCC. LIC. 1 LICENSE y?I'' EXPIRATION DATE . 1W:28/1993 .• .SPRINKL .R JOURNEYM1 This Is to cart11y that uncle,' 111* provisions of ihs G/rwW SOSI10s Iv r,.' • • RESTRICTIONS I EFFECTIVE PATE UC-NO. . I'• Io11oonnp parson andlor lura Is '• • • .i1 P. iNU cernTapiarred as: 00 011:1 is I 10/28/1,991 001403, • FIRE PROTECTION , . UNLMTD CONTRACTOR--F1 • I :RONALD W FOSTER ,•f•I• != i i •-•,— :i8—...:::97046"46 ELM• ST JAMES R SWEENEY • MOTO IBIASTNO EWA ONLY) FEE: .MANSFIELD MA 02845'if.. 13 ST.MORITZ CIRCLE • ``I A OQ t .NOT VALID UNTIL SIGNED SY-LCENSEE AND OFFICIALLY.J;'' WILLI>;IGTON CT 06279 • HEIGHT: STAMPEO •OR -SIGNATURE OF THE coMr/.UCHUN OQB: . ;{' • I SIS Is(-)doeQNEi/lJ6Iil • ) $150. 0 `• E PAI • CARRIED ON THE PERSON OF TORE OF E T I C.NO ri 1 12 O 8 $15 0• 0 THE,HOLDER WHEN ENGAG• 1J ►'l OTHERS •IM011T THUW PINT ED IN THIS OCCUPAYFO • COM.�M '°d5 EFFECTIVE EXPIRES ' ' '' .j 10. la/7.1v7-444Y 10/01/91 10/01/93 • TOWN OF MONTVILLE Fire Marshal's Office Michael E. Kelley 89 FORT SHANTOK ROAD Raymond T.Occhialini Fire Marshal UNCASVILLE, CONNECTICUT 06382 Deputy Fire Marshal TEL: (203) 848-1175 FAX (203) 848-2552 July 7, 1993 Russell Stauffer Building Official 310 Norwich New London Tpke. Uncasville, CT 06382 RE: VFW Hood System Dear Russ, On Wednesday morning I talked to Mr. Mark Visconti of Visco Inc. I advised him of my concerns about the ventilator and return air distances. He will make the separation ten ( 10) feet. Also, Fire Defense Company will be submitting plans for a fire suppression system to be installed in accordance with N. F. P. A. 96, Section 7—i. At this time I would have no problem with the issuance of a building permit so construction can begin. If you have any questions please feel free to contact me at the Fire Marshals Office. Respectfully yours, Raymond T. Occhialini RTO:ch Deputy Fire Marshal pc: file 6 TOWN OF MONTVILLE Fire Marshal's Office Michael E. Kelley 89 FORT SHANTOK ROAD Raymond T. Occhialini Fire Marshal UNCASVILLE, CONNECTICUT 06382 Deputy Fire Marshal TEL: (203) 848-1175 FAX (203) 848-2552 July 1, 1993 Russell Stauffer, Building Official 310 Norwich New London Tpke. Uncas v i. l l e, CT 06382 RE: V. F. W. Hood System Plan Review Dear Russ, On Thursday, July 1, 1993, the Town of Montville Deputy Fire Marshal Raymond T. Occhialini reviewed the plans submitted by Visco Incorporat ion, for the new N. F. P. A. 96 Hood. As a result of this plan review the following does not conform to Code : 1. N. F. P. c1. 96, Section 3-8. 3. 2, required ten feet between the intake and exhaust fan. 2. There is no provisions for a required automatic Fire Extinguishing System. This Office does not approve the plans submitted until the above items are included in the plans. Respectfully yours, 'TiUI Raymond T. Occhialini RTO:ch Deputy Fire Marshal pc: file STA N*1--Z.SS S rE EL GREASE. , S (UV C Y CLQ , I\CF cI CQ C,oDc Boct MAcHPovIcAL. tS. GA. Ex N A UST Cpu_P►i2 S("pp Ly Com,rZ DiAmPEe L►QUI t&NT V Y � ` U.L. LtsT�i) a-12_1w_ 7 9, G.e P E. /�► v m 1 i.,u r‘A. Cup. FL.TEizs . 1 NEW ITEM ON THIS PAGE COMMERCIAL KITCHEN VENTILATORS . BLOWERS i � ,,i,t '• ti v„ 1Y� _ tdAv.,,,--4Yrwl �• Ventilators meet NFPA 96.1991 installs �? M'a ' r M �z , Z + t ▪iy, _tion requirements i-rasr � v ,s�.. L' i 4+ 41 7j',r �. -'it. f r r�• 1r!. r 7 }L • �. fr• j.; r” t � 7 - ? ' •'; • Belt-drive upblast design; 15 and 20" a ,{ i ,• -yics,.y , , .�▪ g `s 3 <Models mount on roof or wall r ® - IA-, �t7t ��.tr` � ' 4fa' m.y � ?' - s0 ., � �• Supplied with variable pitch sheave Kra ii 9`f s ., r a; 4Jr £a , xz0.:I ry ' ' w Y• g - • Remove grease-laden and foul air up to 4S y , L� ai' rr ,7r`• S s_ r` �;A'p17W „`w .y ly;,g=300°F from commercial kitchen ap- !s : '6 't' ,< rt ; ,, i } ? �14Kma . , Zr• f" pliances including grilles,ovens,fryers, ,cxy ff .y?-sv• i{ Mrr � .y 4s+. + :Cli" b ?" Eirg.5'^4, , ' r '+ c• , ` L~ >l . A.,,-it; i -ran es,and steam tables r'�• i4: s' -.r.r~ i.4 ,, fr1 r3 " ' Y ` R-t"' Zvt:l:i,,N � ta • tf ' 4 4rs & r' Y, . 3 +r 4'S`UKs4• Furnished with exterior mounted - , c te, ;'�• ' 104 ;• fs,, tt,c _ r �^ '3 . s� - uweathertight junction box and external sz� 14M4,1; *, :' - •�. " • xyri} r'- ' "' emakc grease drain pipe `�nl ,114f:r >' �?rts 1,}� .. iy - LS 7idK,n 1.hi3r . ry ,Aluminum housing and wheel. Base and y•:-z • ;-1Zvtt,.:supports of galvanized steel. , Externally cooled motor compartment is y;• ;'•'• +^ :y�314. located out of the discharge air stream. =v"e� t... � _ S' r Permanently lubricated ball bearings,1725 'ks- yt r'yr.* �` � +� �s RPM ball bearing motor and drive are a;�� ; packed separately when ordered with 4_; r`:z, r,-",',4,041,:,,a4-.'33?-, ;�j_ri,.r•. ' ,;y ventilator. e..fa - ,� ? { UL Listing under Power Ventilators for vh ,i s' ralas w 3 ����+. • x Restaurant Appliances (YZHW), Subject -+: e C `c.,.�- Y���/ '„,)r' L • ^^,�q. ii a.. tr r .ti.ik `? . t v.,2•. r K'i` -..•,- - rs, r r•1� +,,�. 762.Only for Stock Nos.of ventilators sold %>414- '*' e - ' ti P , f , µ ' complete with motor and drive. Ventila ” .y� r 1r R iL I'• .•• 1� -a. x+; r hr,•+- f 1, ;`; ,?. • 'rr''.-I 15:-.,- tors must be mounted on 16" high steel „titt - n•�, ,:::2ti No:5C312;5CSI3. <'} ° ,li orf, t >t[o 'StO,5GST' i r roof curb to comply with NFPA 96 and UL" Y; 4%L-*1 , t``tt tom s >, •� P Y .y�'-�Z�s'! 2 ShOwh Wit11K r �"'•r� c .� , a.▪� Guide YZHW. 'Z yxu� , w�i=w ` r r .A\tr , r< ▪r.t rr � r'�gsr t Options! -,y �rKri�'s, 'r r .3 2 z K � �- , Dayton Electric Mfg.Co.certi 'oaf, M Grease Collector Bo i-e:;^-"v-`w *�4 -,M - � y ,- fies that the belt-drive venula 3_"�,,.,u`� ,sit 7 tors shown herein are Il- "LM$'" yr.•�- } - 4�` x'' y.4 �� xa tf :3`2�•'ty et ,Zs of ® tensed to bear the AMCA .,i ,iv ..::; 5r,• s t ,,t ,,c" . t +�'y',,, .. ,Y'••�r:;....t..�-r •'s',..••t�:_.._Y_in..:..� sL.,.._ -:.-,,, ..v.-rte �_ -5.,, .4,--,d. .✓!i S-.-.- 1.'.~x..r. Seal. The ratings shown are -+ based on tests and procedures performed in accordance with AMCA.Publication 211 and :T.",==.•,,,, comply with the requirements { of the AMCA Certified Ratings i Program.The AMCA Certified Ratings Seal applies to air performance I} ratings only. • I i .NEW ITEM ON THIS PAGE BLOWERS COMMERCIAL KITCHEN VENTILATORS AND ADJUSTABLE ROOF CURBS • Remove foul air accumulating in_indut ' CT trial and commercial buildings .. at drt • Exhausts grease laden air up-to 300 F from commercial kitchens _ j - \\ A .. • Roof and wall mount • Aluminum and galvanized steel eon — - • I � struction Direct-drive upblast ventilators direct nit' away from building in.accordancerwitL; NFPA Bulletin No.96. '-.- . lilt B irD le Ali—„ic -s.- Six foot 200°C greenfield table- factory; •` p h��,_ ;,. :� wired to motor. Motor- compartment cooled by outside air drawn from este v;- rill E\ lilt ,, • tVill5;r: tube. 115V, 60 Hz, ball bearing motor's• I `^��J sig with automatic thermal protection and S i Class B insulation. ® ' v- No. 30367 rated for 115/230V. UL`Listed •_`r„ Power Ventilators for Restaurant Ex, - ” - - MH12596 ' _ C sc.8,,„ , .v: haust'Appliances (YZHW). Subject 7621 • ,�ic � t; Damper not included. ci Stock, - Dimensions • Dayton Electric Mfg.Co:certifies that the direct drive ventila No. • e c a amigo tors shown herein are Iicensed to bear the AMCA Seal. The 'i grwist MIMS ratings shown are.based on tests made in accordance with 1sw Hy: ivy r AMCA Standard 210 and comply with the requirements of the 40836 2155 21% 20% — q 40399 26 2155 2055 ,,.� AMCA Certified Ratings-Program_•Performance shown is f 4 90399 26 .2151 . 2055 —' direct-drive ventilators without ducts:.RPM-shown is nomina r;try 40400 26 2155 2055 . and the performance is based on actual speed of test.The,.';','., - 32 ' -22% - 24% s- AMCA Certified Ratings Seal applies to air performance rat al (°) 11' thru 134 units,windband is higher.thai only. .,-,,,,,,.,..f._.. A,,..!..:,,,,,',",%,,...; agtb dome. 96-22 REMOVAL OF SMOKE AND GREASE-LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT Duct ' .•♦♦♦♦♦♦♦`.,♦♦♦♦.♦. 744 4r Combustible material iii � 4 3" -. ���i�� .. - ...,- 4. • ,.♦♦♦.. 1 3„r Rik . Wire mesh IT N ,♦♦♦ /4 40 WIWI ronti ...♦.♦..♦..' 1”Mineral wool bat 1"Noncombustible .♦♦♦♦.♦♦♦♦♦♦.♦.♦I spacer O'♦♦♦•♦•♦♦♦♦♦♦♦♦♦• ••.•� '♦::•�♦.:;:♦:.•�•♦♦ 22 Ga. sheet metal Plan section 1" Noncombustible spacer such as stacked washers. lir ,Small diameter pipe. Tubing,or electrical conduit ,♦ Nail or screw anchor a /7 ♦4 , . /. 1v ,„ _ A( Combustible • material N� / / : \ I '' 4 C •����� 411; Duct or ♦ I: 1" Noncombustible 22 Ga.sheet metal 1 spacer ; 6 • ,e\ 4 / s. • a Wire mesh \ / 1"Mineral wool bat 3' -.J 3' Side section Figure A-1-3.2(f) Example of clearance reduction system(b);3 in.clearance to combustible material. 1991 Edition Efficient-Versatile-Lightweight DELTA...10 Delta-10 Mineral Wool Board is manufactured from felted mineral wool fibers bonded together with high temperature binder.It is a highly efficient, semi-rigid type insulation for applications up to 1200°F. hot surface WOOL temperature.* MINERAL There is a wide range of applications for Delta-10 Mineral Wool Board. It is ideal for use on ducts, breechings, ovens, tanks and similar applica- tions. It is easily cut with a knife and will fit snugly over irregular sur- faces. Because of its light weight, large sizes can be applied quickly and easily. Generally, it is applied by means of weld pins,strapping,or mesh, and then finished with metal jacketing, lath and cement, or mastic. Physical Properties Density (per ASTM C-612-83) 10 lb./c.f. Thermal Conductivity (C-177) 75°F.—R=4/in. 75°F.—.25 200°F.—.31 600°F.—.57 600°F.—.57 Moisture Adsorption (Vapor) Less than 1% DELTA �► Corrosion (Steel) None .f INDUSTRIAL Service Temperature (C-411-87) Up to 1200°F.* INSULATIONS * Consult manufacturer f for limitations under elevated temperature applications. Flame Spread (E-84) 10 Smoke Developed (E-84) 0 Does not promote growth of fungi or bacteria Non-Hygroscopic* Sizes Lengths: 48" Widths: 24" Thermal Conductivity (ASTM C-177) Thicknesses: 1", 1'/2", 2", 2'/2", 3" Suggested Thickness 8 0 Various (Hot Face) Temperatures from TIMA's Energy Saving Guide .70 > LI: Temperature Thickness ▪ ` .60 150° 2" • ` O 250° 3" 350° 4" E 550° 6" t .40 750° 9" 950° 10" .30 40.00107 Conforms to: Federal Spec. HH-I-558B 20 ASTM Spec. C-612-83 100 200 300 400 500 600 700 ASTM Spec. E-136 (Incombustible) Mean Temperature °F MIL-I-24244B (Special Order) ASTM C-795-83 and NRC R.G. #1.36 (Special Order) Note: This mineral wool board has a melting temperature in excess of 2000°F.Consult manufacturer for compliance with fire testing specifica- tions such as ASTM E-119. Packaging Packed in strong "shrink-pack" polyethylene containing approximately 96 board feet. ROCK WOOL MANUFACTURING COMPANY Leeds,Alabama 35094 • (205)699-6121 Y U C I cr I 12-' TO N 9 J W i o .o• r 0 0 a- o 141 4 J 1 III a f c_. 1 U i CM I u 7 4CI CI) w 4 4 o' ? ------a E Nw > W ,� 0 0 0 A 9 38 01 0°0 id . 8 \ ' 3 a 2 2 7 d0 _IJ qt 4 D.J i If- J J 3 i LJ 4 Jq °I�¢ J JnC ( C ri a fIlld Z Li: i- cn \- n liq af i T !l \ nL` 'nn i 1 U 7 N N1 Q 6 d It' 0, lJ ? (• \ I £ ov II L & ,0:=MIEN Elm'i _ _ __ _ 11 d — J 6. N .x 3Fl 1 a 3 ;r A Q d a w d -a d 4 1 J O ul O 0 V? \ J l 9 / N _ TOWN OF MONTVILLE Fire Marshes Office Michael E. Kelley 89 FORT SHANTOK ROAD Raymond T.Occhialini Fire Marshal UNCASVILLE,CONNECTICUT 06382 Deputy Fire Marshal TEL: (203)848-1175 FAX(203)848-2552 August 9, 1993 Russell Stauffer Building Official 310 Norwich New London Tpke. Uncasville, CT 06382 RE: V. F. W. POST 10060 Dear Russ, On Monday, August 9, 1993 the Town of Montville Deputy Fire Marshal Raymond T. Occhialini conducted a Final Inspection of the N. F. P. A. 96 Hood and Fire Suppression System which was installed at the V. F. W. Post 10060. Present during this inspection was Myself, Russ Stauffer, Building Official and Mr. Al Ladone, permittee of the V. F. W. Post 10060. As a result of this inspection it was determined that the new N. F. P. A. 96 Hood and the Fire Suppression System meet the requirements of N. F. P. A. 96 and that this Office approves the new hood. If you should have any questions please feel free to contact me at the Fire Marshals Office. Respectfully yours, Raymond T. Occhialini RTO:ch Deputy Fire Marshal pc: file .. r V 1° C" / TOWN OF MONTVILLE Building Department 117 848-7166 APPROVED BUILDING PERMIT OR TRADES PERMIT For 180 Days Permit No: 10903-E Approval Date: 7/29/93 Expiration Date: 1/29/94 Estimated Cost : 300 . 00 Fees: 10 . 00 PRF: C.O: Owner: V . F.W . Post 10060 Address : 91 Raymond Hill Road Tel : 848-3750 Job Location: 91 Raymond Hill Road Code: 11 Contractor: James Ladd Address: Yantc Tel : 887-5195 Stick Built: Modular Home: Manufactured Home: Commercial : x Addition: Garage: Car Port : Shed: Remodeling: Roofing: Siding: Fireplace: Chimney: Windows : Pool : Demolition: Plumbing: Heating: Electrical : x Air Conditioning: Gas : Patio: Porch: Deck: New: x Repair/Replacement : Type of material used/description: wiring in EMT pipe for hood ansul system Size: Type of Heat : Fireplace: No.of Stories : No. Rooms : Breezeway: No. Baths : Garage: Use: I hereby certify that the proposed work will conform to the Basic Building Code and all other Codes as adopted by the State of Connecticut, and the Town of Montville. /� Applicant 's Signature: /�in-a� £ - cDate: 7 - 29 - 93 If signed by Contractor/, type of . cense/regi i . ion & No: r f--/ 0 / 1/.yp Building Official 's Signature: ....,r.4- A( •.I_�-- // �, •Date: —a j — Q 3 Date of Health Dept . Approval : AM', Date of Zoning Approval : W/ e4 THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE BUILDING CODE, SECTION 119. 1 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO ANY USE OF THE STRUCTURE. TOWN OF MONTVILLE Building n Department artme nt P • Application for a Permit Owner: !l 1', Gi. /D 0 6 0 Address: Tel : ( 2 d Job Location:cl/ R , m On d )-/,// ed Contractor: .j qrn P. S J^cxc2J Address: Cert e cce / .7e ,dei 't Tel : g�'9 ,yc,n �"i C e 063 7V Stick Built: Modular Home: Manufactured Home: Commercial : 1/ Addition: Garage: _ Car Port: Shed: Remodeling: _ Roofing: Siding: _ Fireplace: Chimney: Windows: Pool : Demolition: Plumbing: _ Heating: Electrical : "Air Conditioning: Gas: Patio: Porch: _ Deck: Retaining Wall : New: Repair/Replacement: _ Type of Material/job description: W, r i na n fi /y) T R p,_ Size: /2_ Type of Heat: Fireplace: No. of Stories: No. Rooms: Breezeway: No. Baths: Garage: Use: r. 1 610 TOWN OF MONTVILLE C/k Building Department 848-7166 APPROVED BUILDING PERMIT OR TRADES PERMIT For 180 Days Permit No: 10937-G Approval Date: 7/28/93 Expiration Date: 1/28/94 Estimated Cost: 1 , 000 . 00 Fees: 10 . 00 PRF: C.O: Owner: VFW Post 10060 Address: 91 Raymond Hill Road Tel : Job Location: 91 Raymond Hill Road Code: 11 Contractor: David McCarthy Address : 6 Ridgewood Dr . Tel : 444-7794 Stick Built : Modular Home: Manufactured Home: Commercial : x Addition: Garage: Car Port : Shed: Remodeling: Roofing: Siding: Fireplace: Chimney: Windows : Pool : Demolition: Plumbing: Heating: Electrical : Air Conditioning: Gas : x Patio: Porch: Deck: New: x Repair/Replacement : Type of material used/discription: installation of Bik . steel gas line for kitchen stove Size: Type of Heat : Fireplace: No.of Stories : No. Rooms : Breezeway: No. Baths : Garage: Use: I hereby certify that the proposed work will conform to the Basic Building Code and all other Codes as adopted by the State of Connecticut, and the Town of Montville. ,- \) j3 Applicant 's Signature: Date: �- _�� � If signed by Contractor, type of license/registration & o• D-°`14/"1 ' 1 Building Official 's Signature: *1 11 Date: ":77- Zi 17 ? Date of Health Dept . Approval : 4Yr // Date of Zoning Approval : A)/e9 THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE BUILDING CODE, SECTION 119.1 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO ANY USE OF THE STRUCTURE. �DO 7i^ I TOWN OF MONTVILLE ! ` 3 • yF O, OD Building Department Application for a Permit Owner: V �Gj Address: Tel: Job Location: /1 4- y y PC Contractoracti--•i l^-oltY0L- Address: Kj.j -w-� S Tel : t11-775tj Stick Built: Modular Home: Manufactured Home: commercial: Addition: Garage: Car Port: _ Shed: Remodeling: Roofing: Siding: Fireplace: _ Chimney: _ Windows: _ Pool : Demolition: Plumbing: Heating: _ Electrical : _ Air Conditioning: _ Gas: V Patio: _ Porch: _ Deck: _ Retaining Wall : _ New: _ Repair/Replacement: Type of Material to be used/job description: Rik -s4 --eI pip Size: Type of Heat: Fireplace: No.of Stories: No. Rooms: Breezeway: No. Baths: Garage: Use: TOWN OF MONTVILLE n; Fire Marshal's Office Michael E. Kelley 89 FORT SHANTOK ROAD Raymond T.Occhialini Fire Marshal UNCASVILLE,CONNECTICUT 06382 Deputy Fire Marshal TEL: (203)848-1175 FAX(203)848-2552 { July 30, 1993 } Russell Stauffer Building Official 310 Norwich New London Tpke. Uncasv i l l e, CT 06382 RE: GAS PIPING TEST i- MONTV ILLE V. F. W. Dear, Russ, On Thursday, July 29, 1993 at 1230 hours, the Town of Montville Deputy Fire Marshal Raymond T. Occhialini witnessed a gas piping pressure test at the Montville V. F. W. This test was conducted in accordance with N. F. P. A. 54, Section 4-4. As a result of this test the new gas piping passed. ' If you should have any questions please feel free to contact me. Respectfully yours, (4)4ft417eak04// -- Raymond T. Uccnial inl RTO:ch Deputy Fire Marshal pc: file