HomeMy WebLinkAboutLP Furnace and A/C 2017 TOWN OF MONTVILLE
Building Department
310 NORWICH NEW LONDON TURNPIKE
UNCASVILLE, CT 06382-2599
TEL. (860) 848-3030 X382 FAX. (860) 848-7231
MECHANICAL PERMIT
Permit Number: M2017-0149 Date: 28-Aug-17 Map/Lot: 034/001-000 Owner ID: 3272000
r
Project Location: 437 KITEMAUG ROAD Unit:
Job Description: Install Central LP Furnace&A/C.One Upstairs&One Downstairs I
4
Owner Nam Kyle Champagne&Joseph Giangrasso Tenant Name N/A t
Careof:
99 Middle Road
Preston CT 06365- _ Telephone: ___
1.
Applicant Name Independent Mechanical Inc. Telephone:
DBA: Lic/Reg Type S9
Lic/Reg N 403243 3
P.O.Box 304
Exp Date: 31-Aug-17
Uncasville CT _ 06382-
Construction Value Permit Fees Construction Information
Building Value: $0.00 Building Fee: $0.00 Use Group: IRC
Plumbing Value: $0.00
PlumbingFee: $0.00 Code: 2016 State Building Code
Mechanical Valu $14,500.00 Mechanical Fe $180.00
Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type IRC
Total Value: $14,500.00 Penalty Fee: $0.00 Permit Code: R5
C of 0 Fee: $0.00 Comment
Plan Review Fe $0.00
State Ed Fee: $3.77
Total Fee Paid: $183.77
It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance:
Field set of approved construction documents shall be available onsite during all inspections.
BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL,ELECTRICAL PERMIT INSPECTIONS
❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test
❑ Deck Piers ❑ R Electrical
❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed
❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding
❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: 0
❑ Framing ❑ R HVAC
❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test
❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION
❑ Insulation El Certificate of Approval
'fic f Oc ancy
Building Official's Approval: �.�
Town of Montville
Building Department
310 Norwich-New London Tpke.
Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231
RESIDENTIAL PERMIT APPLICATION FORM Permit No.: 1fl O 7 01 +9
Type of Work Occupancy Type Permit Type
❑ New Construction ❑Single Family ❑Building
[jikddition ❑Two-Family ❑ P mbing
lEr Alteration 0 Townhouse Mechanical
❑Accessory
Structure ❑ Electrical CRS#:
Property Address: 1137 6
(Number) (Street) (Unit)
Job Description:kI STIXL � �q L� *,,,�,J�� ? C
0/577-/‘,f I- ..,(4)A.tr.7791/CS
Owner: JoF E *ii,,sso
Address:
City: State: Zip Code: Telephone( )
Applicant: APE )2) •;i, MCc#1.1,k.J/C1..) C
DBA:
Address: /o so/
City:69,.JGf35(✓i L.4—c State: Zip Code: Telephone( )
Contractors - Complete the Following:
License Type: .S79 License No.:0V0 -/3 Expiration Date: 08 3/ /
I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town
of Montvi and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a
permor such work as described above.
By checking this box, I will follow the requirements of the 2014 NEC as the alternative compliance per section E3401.1 of the Residential Code,
instead of the electrical requirements in chapters 34 through 43 of the Residential Code.
COwner/Agent Signa CJ Date: �3/i. i I� 1
Construction Value Permit Fees
Building Value: Building Fee:
Plumbing Value: Plumbing Fee:
Mechanical Value: /9 ,rEc) . OC"7 Mechanical Fee:
Electrical Value: Electrical Fee:
Total Value: /y 1-0'D Penalty Fee:
C of 0 Fee:
Plan Review Fee:
State Ed Fee:
Total Fee:
Revised.-August 23,2007
Court 437 Kitemaug
ITEM QTY $/UNIT TOTAL
Building Plumbing Mechanical Electrical
BUILDING AREA
Basement,Finished SF $ 41.96 $ - $ -
Interior Renovations SF $ 36.09 $ - $ - $ -
AMENITIES
Kitchen EA $ - $ - $ -
Full Bathroom EA $ - $ -
Half-Bathroom EA $ - $ -
GARAGE
Detached SF $ 71.53 $ - $ -
MECHANICAL
Warm-Air n Y/N $ -
Hot Water n Y/N $ -
Electric n Y/N $ -
Air Conditioning n Y/N $ -
ELECTRICAL SERVICE
Upgrade Amps $ -
Subpanel EA $ 699.00 $ -
Gen Set EA $ 3,850.00 $ -
SOLID FUEL BURNING APPLIANCES
Prefab Metal Fireplace EA $ 6,497.70 $ -
Masonry w/lfireplace EA $ 7,096.65 $ -
Masonry w/2 fireplaces EA $ 11,095.70 $ -
Wood Stove,free standing EA $ 2,692.25 $ -
Wood stove insert EA $ 1,859.77 $ -
DECKS,PORCHES,SUNROOMS
Deck SF $ 44.07 $ -
Porch SF $ 149.38 $ -
Sunroom SF $ 176.90 $ - $ -
POOLS&HOT TUBS
Hot Tub EA $ 8,016.25 $ - $ -
Inground Pool EA $ 31,550.00 $ - $ -
Above Ground Round EA $ 6,299.46 $ - $ -
Above Ground Oval EA $ 7,019.75 $ - $ -
Pool Heater EA $ 8,984.25 $ - $ -
Inflatable Type Pool EA $ 1,200.00 $ - $ -
SHEDS
w/o electrical SF $ 25.55 $ -
w/electrical SF $ 26.85 $ - $ -
RENOVATIONS
Roofing,Overlay SF $ 3.50 $ -
Roofing,Strip&reroof SF $ 4.50 $ -
Roof Sheathing SF $ 1.51 $ -
Siding SF $ 6.75 $ -
Windows - EA $ 550.00 $ -
Skylights EA $ 1,051.10 $ -
Doors,Exterior - EA $ 601.50 $ -
Oil Tank,275 Gallon EA $ -
Oil Tank,550 Gallon EA $ -
MISCELLANEOUS CALCULATIONS $ 14,500.00
Solar Install n
TOTALS $ - $ - $ 14,500.00 $ -
PERMIT FEE CALCULATIONS
Construction Value Fee
Building $ - $ -
Plumbing y $ - $ _
Mechanical y $ 14,500.00 $ 180.00
Electrical y $ - $ _
Plan Review Fee y $
Certificate of Occupancy Fee $ -
Plan Review Fee $ _
State Education Fee $ 3.77
TOTALS $ 14,500.00 $ 183.77
Figures are based on the 2006 RS Means Residential Cost Data
----17 _ ,,00 ,/ II AasaA a uow: :A9 pan!aaab
7 .--- y
OUT :oN)13e4D
00'0$ ' 12A uo!;!lowaa
00'005 VT$ :anleA uo!pnJ;suoD 00'0$ :1!pa-0 aa!d
00'0$ :Noaq0 al!d
00'0$ :gseD aJ!d
00 0$ :;!Pa-0 a;e;S 00'0$
:4!paa0 6PI8
LL E$ :)Iaagj a;e3S LC£8l$ :Naagj 6P19
00 0$ :gse'J a;e;S
00'0$ :yseD 6PI8
papapo)saaA 4napaauuo:;o a4e-4s
papalioD saaj uMoj
6newajiN L£ti :ssaippy qoC
!eu!ouequaW;uapuaaapul :woJj pan!aaall
inn :oN;d!aaab
LT-Dnd-TZ :a;ea
idTaaag ajy
/uauq ivdaa gullying
aj1Tn1uoy1[fo un(oJ
Town of Montville
/ Building Department
CONSTRUCTION PERMIT APPROVAL
I/57 4-7E7_44 nu tkcets---iiy _ et938
Property Address 1
J
2 —.' i cr s A vts7�2J
Job Description / ,(A.)N
Required
Department
Approval Permit Issuance Approval
Tax Collector C D -� �''`"�-- R1.2111 7
Signature/date
Comments:
Fire Marshalif4/ �149111/
Signature/date
Comments:
❑ Planning & Zoning
Required for all permits except Signature/date
Plumbing,Electrical,Mechanical,Roofing,Siding,Windows&Doors
❑ Health Department
Required for properties with private septic or well Signature/date
Comments:
❑ WPCA, Administrative
Required for properties on sewer Signature/date
Comments:
❑ WPCA, Operations
When Required by WPCA Signature/date
Comments:
❑ Department of Public Works
Required when project includes driveway work or certain drainage requirements Signature/date
Comments:
❑ Montville Police Department
Required for all permits EXCEPT one and two family residential Signature/date
Comments:
❑ Copy of State Dept. of Transportation Certificate
Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official copy of STC Certificate of Operation required—per
CGS 14-311
Signature/date
Building Department Final Inspection
7ievisedMarch23,2015
Sid Harvey Industries, Inc.
Heat Load Summary Report for Independent Mechanical Kitemaug
Room Square Heating Loss Hydronic Heat Latent / Sensible Cooling Gain Cooling Cooling
Name Ft. BTUH Linear Ft. Gain BTUH BTUH Tons CFM
FOYER 168 3333 5.55 263 /1108 1371 0.11 39 l
DINING 182 4878 8.13 685 /4526 5211 0.43 174 n( c_-,
KITCHEN 299 6092 10.15 1268 /6792 8060 0.67 269
POWDER 32 773 1.29 50 /994 1044 0.09 35 o
DOWN B1 132 3147 5.24 407 /2266 2673 0.22 89
FIREPLACE 182 3457 5.76 485 /3061 3546 0.3 118
WINDOW 143 6678 11.13 424 /5919 6343 0.53 211
LIVING 273 6272 10.45 828 /64397266 0.61 242
UP B1 182 3267 5.44 485 %3435.,..v,.. 3920 0.33 131
B2 182 3267 5.44 485 /3435 3920 0.33 131 i
B3 165 2378 3.96 458 /3126 3584 0.3 119
BATH 40 911 1.52 63 /1381 1444 0.12 48
M BATH 45 980 1.63 70 /1408 1478 0.12 49
WIC 48 334 0.56 75 /421 496 0.04 17
MASTER 351 6290 10.48 950 /6988 7938 0.66 265
TOTALS 2424 52056 86.76 6996 151299 58297 4.86 1937
Disclaimer
These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a
professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a
complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken
into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total
BTUs.
Pf@j3if@ifi§4'43 ®11 ti in O'Brien Quick Loads Pro-Version 1.01 -SN:QP-070101-30020