Loading...
HomeMy WebLinkAboutDeck l Town of Montville Building Department Date /G'/Field Inspection Notice Permit # e Job Location Approved Type of Inspection r' ❑ Not Approved Please call for re-inspection when the following corrections have been completed: t- i uilaing official Town of Montville BUILDING DEPARTMENT 310 Norwich-New London Turnpike Uncasville, CT 06382 (860) 848-3030, Ext. 382 Building Permit Permit Number: B2003-0464 Date: 22-Aug-03 Map/Lot: 030/043-043 Owner ID 2001 Job Location: 4 AMANDA CT Unit Job Description: Pool Deck Owner: Contractor: Michael J and Charyl L Fleener Michael Fleener 4 Amanda Court 4 Amanda Court Uncasville, Ct. 06382- Uncasville CT 06382 Telephone: (860) 367-0668 Lic/Reg Type/No. 0 Exp Date: Tenant: Self Telephone: Construction Values Permit Fees Construction Information Building Value: $2,962.00 Building Fee: $16.00 Use Group: R4 Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 1995 CABO Mechanical Value: $0.00 Mechanical Fee: $0.00 Construction Type: 5B Electrical Value: $0.00 Electrical Fee: $0.00 Permit Code: R10 Other Value: $0.00 Other Fee: $0.00 Comments: Total Value: $2,962.00 CO Fee: $10.00 Plan Review Fee: $1.60 State Ed Fee: $0.47 Total Fees: $28.07 It is the owners resnonsibilitV to schedule the following inspections (minimum 48 hours notice required): Footing - Prior to pouring concrete ❑ Rough HVAC ❑ Backfill - Footing drains and waterproofing ❑ Fireplace Throat ❑ Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble Rough Framing ❑ Firestopping/draftstopping ❑ Rough Electrical ❑ Insulation ❑ Electrical Service ❑ Final Inspection ❑ Rough plumbing and leak test 0 Certificate of Occupany ❑ Gas piping and test Building Official's Signature: Town of Montville 41 Building Deponent Permit # 310 Norwich New London Tpke. ,Tel. 848-3030, Ext 382 Uncasville, Cr 06382 Fax. 848-7231 One & Two Family. Building Permit Application Form El V w Cowtrucdme AMtlm El Alteration ® Accessory Structure Job Location Job Description/Materials Owner.---A. Mailing Address At State ~'S- Zip o en !&Z- Tel ~ o /_'54=2 Contractor Mailing Address. City State Zip Tel --J-J Contractor's License/Registration Type & Number . Exp. Date !_1 I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Owner /Agent Signature " Date c~ `5, Construction Value Fee Building $ $ Plumbing $ $ Mechanical $ $ Electrical $ $ Other $ $ Certificate of Occupancy $ Plan Review Fee $ State Education $ Total $ $ (See *verse side for additional requirements) Town of Montville Residential Pel+;mit Requfrements ❑ Two (2) complete sets of construction documents to scale are ( ) required and shall show the following information if applicable. This list is not.all-inclusive, additional information may be required for your particular project. • Supporting Documentation • Building Section(s) & Details fkn~ signed and dated Building Permit Application Floor-to-floor heights Permit - calculated upon completion of plan review Material type, size, and spacing Completed building permit affidavit for property owners or sole Stair details (rise, run, treads, nosing, width, headroom) proprietors or copy of workers compensation insurance Handrail details Copy of Contractor Registration or license Guardrail details Construction ctpermit sip-off sheet signed by all departments Roof ventilation Heat loss calculations • Framing plans Engineering data for steel beams, engineered lumber, roof trusses or any - other engineered products or design Design loads - for floors, ceilings, roofs Street address of project on all drawings and documents Bearing partitions Direction of framing • Site phm Spans, beam Wood species and grade Property lines Framed openings Distance from property to structure Sheathing type and thickness Structure dimensions Window and door header sizes Driveway Decking material, size, spacing Topography (existing and proposed) Note: Unusual structural conditions may require that additional Fooling drain invests, outlet and separation engineering back up be submitted Proposed utilities Wetlands and flood zone limits and elevation • Chimneys 8nd Fireplaces Signed by P & z, Wetlands, Uncas Health, WPCA (:learauces tu combustible materials Foundation Plan Manufactures data for metal flues Exterior flesh air source far fireplaces Assumed soil bearing pressure Flue sizes Dimensions Manufacturers data and installation instructions for metal fireplaces Wall thickness Footing sizes • Electrical Plan(s) Anchor bolts, size and spacing Panel location Window and door sizes and locations (s) with main size Hatchways meter socket location Columns Outlet locations Floor construction data . Glace outlet locations Drainage details Smoke detector locations Waterproofing details lights-and switches Crawl space ventilation Appliancoequipment circuits Crawl space access Stair illumination Concrete strengths • Mechanical plan(s) • Floor plan(s) Dryer vent Dimensions Bathroom exhaust ventilation (natural or mechanical) type and size Door and window sizes, egress window Hood exhaust Glazing in hazardous locations Type of heat Garageldwelling opening protection. Heating. ventilation, and air conditioning plant location Garageldwelling separation Oil tank size, location, and piping Kitchen layout LP-Gas tank location, size, and piping Bathroom layouts, tub sizes in gallons, space clearances Make-air requirements Indicate use of all rooms Manufacturers data for equipment Stair location Attic access location and size • Plumbing plan(s) Square footage for each habitable lever of the structure Building trap location if on municipal sewer Required light and ventilation for each habitable room Sewer location Domestic water location • Elevations - minimum of two required _ Manufacturers data for whirlpools, corner tubs, & larger tubs Type of siding Water heater size, type, and location Roofing Other finishes Finish grades Note: One set of an_ roved plans is required to be kept on Building heights Height of chimney above roof site at all times. Roof pitch '00te Chick aaress ~,r ee~` Sob P NOO r, Sh $ a by - $ Efec 20 EA $ 816.43 400 ^ EA $ 1,519.19 $ Breezewa - EA $ 6,039.29 $ $ Open -----__190 SF $ 15.59 Enclosed $ 2,962.10 Porches "--------SF $ 94.76 $ Open SF Enclosed $ 62.69 $ SF $ 123.90 $ TOTAL BUILDING CONSTRUCTION COST $ 2.962.10 PERMIT FEE Building $ 2,962 $ 16.00 Electrical $ $ $ CO Fee $ 10.00 Plan Review $ 1.60 State Ed Fee $ 2,962 $ 0.47 Total Fees $ 28.07 STATE OF CONNECTICUT WORKERS' COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn. Gen. Stat. § 31-286b) Property located at: _ -1 In the town of- Name of building permit applicant: Please check o e: 1. am the owner of the above property. 2. I am the sole proprietor of a business. 2A. Name of business: 2B. Federal Employer Identification Number (FEIN) Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or principal employer" may provide either a certificate of workers' compensation insurance or a "sworn affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: 1. 1 do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2. 1 intend to act as a general contractor or principal employer. Applicant must either provide a certificate of workers' compensation insurance or sign the affidavit below. Affidavit I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor, subcontractor, or other worker before he/she engages in work on the above property in accordance with the Workers' Compensation Act (Chapter 568). I understand that pursuant to § 31-275 C.G.S., officers of a corporation and partners in a partnership may elect to be excluded from coverage by filing a waiver with the appropriate District Office; and that a sole proprietor of a business ' not req • d to ve cov ge unless he files his intent to accept coverage, Signature of applicant Subscribed and sworn to before me this day of r0licifs - 20 LISA ERR4 (Not T r of the"S~tperi Court) r Fa fif4,~;it ION EN EXP A Town of Montville Building Department 848-3030, Ext 382 ONE & TWO FAMILY CONSTRUCTION .PERMIT SIGN-OFF SHEET 4 Property Address Job Description: I O -V` 1 Aeod-f 47 The owner/agent shall be responsible for the completion of the form, no certificate of occupancy will be issued until all signatures below have been obtained. HEALTH DISTRICT 848-3030-882 Approved ❑ Permit ❑ Not Applicable Septic System Date Approved ❑ Permit # ❑ Not Applicable Private Well Date -WPCA DEPART NT 848-3030, Ext. 881 Approved ❑ Permit Not Applicable unicipal Sewer Date House Trap ❑ Outside ❑ Inside Approved ❑ Permit # ❑ Not Applicable Municipal Water Date DEPARTMENT OF PUBLIC WORKS 848-7473 Approved El Permit ❑ Not Applicable Director Date PLANNING & 740NING DEPARTMENT 848-3030. Ext. 81 z4v 2L& In-Compliance Rl ox Permit P,3- 2 ❑ Not Applicable Zoning Date In-Compliance ❑ Permit ❑ Not Applicable Inland-Wetlands Date Town of Montville o 5 Plan Approved for Constructlow, mal eftail not be construed a pem* * or approval of, vlolattondtlo provisions of Conn Building Code a N xta~ 0 %914A 400 or iAtLmw i~t ~L.t i t?r ~}~'~j mil✓C✓ ~ly~Ji~l~ v'~ ~~,+~a,~ . i -.~.1 m C\j G 0,, + i ~aoaa S ~-73"~Zv ! D Jri~v+~ Gc rz'f2, r, Zr p&rc-h- To ,A3 VP c.r DS c r l 6Si H4o~~~s- q2' 1J~c•i~~25-- STEP N 3 ()L ISh &bwt mil jj PIT, L 3 X3 - aver ~:•sin ~~~a~~< 40 0 40 40 e0 FEES SCALE: 1"!40' LOT 42 ` S 131.71 OT 43 z , 20,0 9 sq!-ft 9 1 0.4 0 o&es 24 P 34' 1 + 00 ol ,co R a . O LOT 44- I. 382.-- I 1 ' i 46 3 s ' r-- CaT~CN~COO r LEGEND PROPERTY/STREET LINE PLOT PLAN EASEMENT LINE LET 43 ooo o STONE WALL CHESTERFIELD HILLS ESTATES INLAND WETLANDS OMIT 4 AMANDA COURT s1Vi. SWAMP/MARSH ----350---- EXISTING CONTOUR MONTVILLE, CONNECTICUT 5 PROPOSED CONTOUR WATER UNE SCALE: 'Iri=40 DATE: FEB. 20, 1992 SANITARY SEWER BY: BENNETT & SMILAS ENGINEERING, INC. Sy SEDIMENT BARRIER 44 WOOD CART LANE, HADDAM. CT L, -x x--- FENCE