Loading...
HomeMy WebLinkAboutCertificate of Occupancy for SFR TOWN OF MONTVILLE BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the work described conforms substantially to the requirements of the State of Connecticut Building Code and is being issued in accordance with Connecticut General Statute Section 29- 265 and the State of Connecticut Building Code and is hereby approved for use and occupancy. 1 Property Address: 16 ALLISON'S WAY „Unit: a Job Description: Sin Ike Family Residence Permit Number: B2005-0572 Map/Lot: 035006-00 Use Group: R-4 Construction Type: 5B Code: 1999 State Buildin Code w 2004 Amendment Special Conditions: i ` Owner: Wayne K & Joann C Records Design Occupant Load: N/A Automatic Sprinkler System Required: 0 16 Allison's Way Automatic Sprinkler System Provided: None Oakdale CT 00 70 Friday, December 01 2006 uildi fficial Signature: CO Issued: Town of Montville Building Department Field Inspection Notice October 13, 2006 Address: 16 Allison's Way Job Description: SFR 82005-0572 - M2005-0216 - P2005-0116 - E2005-0291 - M2006-0026 gas & Permit Permit Number s): vent free fireplace Date: Not Approved A 7roval Date: Deficiencies Special Date FOOTINGS Conditions 918105 DJ • . Verify anchor 9128/05 JS BACKFILL ° bolt spacing FRAMING 11/21105 DJ • 12/21/05 DJ ELECTRIC TRENCH • MENOMMOMM~ ELECTRIC 12121/05 DJ SERVICE ° • Kraft face behind fireplace can not be left exposed, • 2115106 JS must remove Kraft facing and install plywood or 1/30106 JS INSULATION sheetrock • OK to sheetrock other areas s 3129106 JS No shut off valve at fireplace 417/06 JS GAS LINE TEST . What is Tee in basement for? ROUGH PLUMBING 1110106 JS • • Equipment not installed • ROUGH HAVC 1/10106 JS • Flex duct has been restricted in size in the basement in 1130106 JS the area of bedroom 2 Pictures 6&7 ROUGH 1110106 JS ELECTRICAL • . Draftstop gable end wall in room over garage Picture 3 • 1/10106 JS • Draftstop bottom plate in vicinity of fireplace DRAFTSTOPPING • Draftstop wall to ceiling area over fireplace alcove 1130106 JS Picture 4 1/30/06 JS • Draftstop bottom plate in vicinity of the fireplace (below to receptacle) • Insufficient bearing under LVL at stair to room over • garage Picture 1 • Attic access not framed out 4 ply LVL in basement is not bolted I -joists require blocking over supports?????, blocking required per engineered plans • What is the 3 ply LVL in the basement that runs from front to the back of the house for? It is not properly supported Picture 2, blocking required between FRAMING 1/10/06 JS beam and wall above 1130106 JS Basement stair header is not nailed to the hanger I-joist hangers insufficient number of nails in hanger, check specs (USP #THF23118) Picture 5, mfg requires dimpled holes to be nailed • Approved plans not on site for review, could not verify the number of hold downs required nor plywood blocking • STOP WORK has been posted, not constructed in accordance with approved plans Rev. Date: 8/4/05 Page 1 of 2 Town of Montville Building Department Field Inspection Notice October 13, 2006 • Construction permit sheet with Health & zoning • AMENDED PLANS 2/15/06 JS approval signatures required • Fee due of $186.33 • • A low water cutoff device is required on all boilers. • • Insulation in attic has been disturbed in numerous areas, reinstall where needed. • The attic door located in the room over the garage must have a gasket to prevent drafts. CERTIFICATE OF 6/26/06 DJ • The knee wall or railing wall located in the room over 10113/06 JS OCCUPANCY the garage requires one electric receptacle in this area • The exhaust fans in the master bath and front lav must be vented directly to the outside. • The sheetrock in the garage must be taped with two coats of compound, minimum • OK to insulate (1/30/06 JS) Picture 1 - Field Inspection of 1/10/06 JS Picture 2 - Field Inspection of 1/10106 JS Picture 3 - Field Inspection of 1110106 JS J'i Picture 4 - Field Inspection of 1/10/06 JS Picture 5 - Field Inspection of 1/10/06 JS Picture 6 - Field Inspection of 1/10/06 JS -r Picture 7 - Field Inspection of 1/10/06 JS Rev. Date: 8/4/05 Page 2 of 2