BUILDING PERMIT
Permit Number: B2005-0448 Date: 17-Aug-05 Map/Lot: 035/007-000 Owner ID: 59000
Project Location: 14 ALLISON'S WAY Unit:
lob Description: Single Family Residence
Owner Name: RTT Development Tenant Name: N/A
Careof:
35 Blais Road
Uncasville CT 06382- Telephone:
Contractor Name: Property Owner Telephone: (860)848-2852
DBA: Lic/Reg Type: NHC
Lic/Reg No: 1795
Exp Date: 30-Sep-05
Construction Value Permit Fees Construction Information
Building Value: $240,867.00 Building Fee: $1,928.00 Use Group: R-4
Plumbing Value: $23,285.00 Plumbing Fee: $192.00 Code: 1999 State Building Code
w/2004 Amendment
Mechanical Value: $16,500.00 Mechanical Fee: $136.00
Electrical Value: $13,622.00 Electrical Fee: $112.00 Construction Type: 5B
Total Value: $294,274.00 Penalty Fee: $0.00 Permit Code: R2
C of O Fee: $25.00 Comments:
Plan Review Fee: $236.80
State Ed Fee: $47.08
Total Fee: $2,676.88
It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance:
Field set of approved construction documents shall be available onsite during all inspections.
BUILDING PERMIT INSPECTIONS PLUMBING MECHANICAL ELECTRICAL PERMIT INSPECTIONS
FV~ Footing - Prior to pouring concrete R Plumbing and leak test
W/ Deck Piers R Electrical
F-/~ Backfill - Footing drains and waterproofing ❑d Elec Trench - with conduit installed
W Concrete Slab - Prior to pouring concrete ❑ Pool Bonding
R Anchor Bolts - with sill plate and prior to floor framing Electrical Service CRS No: 0
Framing R HVAC
❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test
FV1 Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION
❑d Insulation ❑ Certifica of Approval
d C icate of Occupancy
Building Officiars Approval:
Town of Montville
• Building Department
Manufactured Residential Plan Review Form
Date: 8 two b i
Job Address: ~f / / 1 S o g! `S !d -s
Job Description: / • `Ocl a r F R
The following information must be included on both sets of plans or accompanying documents (two sets are required) (C.G.S. 29-252a.) This list is offered as a
guideline only. It is not meant to be all-inclusive for every permit application, nor is it meant to take the place of the building code.
Your application is beine reiected for the followine reason(s) that are checked-off or commented on:
Supporting Documentation Retaining Walls Garage
Building permit application not completed Plans required Plans required
Permit fee $ Documents required to be stamped and signed by a Minimum 5/8" Type X gypsum board separation
Permit fee to be alculated CT registered Professional En 'neer (on garage side) to all living spaces - all
Worker's comp. Affidavit or worker' comp. Foundation Plan combustible support framing to be covered with
Insurance required Plans required minimum 5/8" Type X gypsum board if it supports
Copy Contractor's registration or license Dimensions habitable rooms
Construction permit sign-off sheet with approvals Wall thickness Openings between the garage and residence
required Footing sizes required to have a minimum 13/8" solid wood
Provide all documentation to show compliance Column footings - size door, 13/8" solid core steel door, 13/9"
with the 2003 International Energy Conservation Frost protection not indicated or insufficient honeycomb core steel door, or 20 minute rated
Code (www.enerSYcodes.gov) Foundation - indicate the assumed soil conditions door from the garage to the house and its basement
attic
Street address of project on all drawings and that the system has been designed for or provide or
documents required engineering data. If presumptive soil conditions Indicate self-closing devices on all doors from
Field set of approved plans need to be picked up cannot be met, provide soil bearing engineering garage to the house and its basement or attic
from our office data Indicate slope for garage floor
Two sets of construction documents required, this Concrete strength - foundation, floors, exterior Elevations
includes engineering data, calculations, and other porches, walks, slabs Plans required
documentation Vapor barrier between sub-grade and concrete Type of siding
Wind Limitations Design Criteria basement floor required Type of roofing
Submit supporting data to show conformance with Floor thickness and control joint location Finish grades
the wind limitations (3 second gust @ 115 mph) Lally column size, attachment and spacing Building heights
Design publication needs to be identified (WFCM, Waterproofing details Dimension height of chimney above roof
chapter 3, WFCM, chapter 2, ASCE 7-2002) Fireplace/chimney base Roof pitches
Documents required to be stamped and signed by a Concrete piers and anchor details Elevations to match site grading
CT registered Professional Engineer Foundation drainage Building Section(s) & Details
Submit anchoring requirements for the Beam pockets - minimum clearances Plans required
manufactured home Engineered foundation plan required Floor-to-floor heights
Shearwalls not identified or insufficient Flashing detail - windows and doors - type,
Ridge connection not identified or insufficient __Gra paces material
Roof-to-wall connection not identified or Crawl space data - clearance to joists, slab Additional sections and details required
insufficient thickness (if provided), vapor barrier Fire-resistance rating details required for exterior
Wall-to-wall connection not identified or Crawl space ventilation, location, type and size wall(s)
insufficient Crawls ace access, location and size Wall/ceiling frreblockin detail
Wall-to-sill connection not identified or Floor plan(s) Stairs
insufficient Plans required Stair not shown on basement plan
Provide engineering data for the piers resist Construction documents shall be of sufficient Riser height not indicated
gravity, lateral, shear and uplift loads, stamped and
signed by a licensed design professional clarity to indicate the location, nature and extent of Tread depth not indicated
Hold-down devices, location and type not the work proposed (11106.1.1) Nosing required for closed risers
identified or insufficient Construction documents are to match the Handrail required on at least on side of the stair
Foundation anchor spacing not identified or orientation on the site plan reversed plans are not Stair to be minimum 36" in width above the
insufficient acceptable, a full plan review can not be handrail height
Cold-formed steel framing shall be designed in performed with the submitted documentation Handrails and guardrails - detail, including height
accordance with COFS/PM-2001 edition Construction documents are incomplete or un- and maximum opening, handrail cross-section,
Site plan clear, a full plan review can not be performed with continuity and required returns
the submitted documentation Show minimum headroom in stairways -
Plaus required Basement floor plan required measured from nosing plane to lowest point of
Plan does not match building plans Dimensions ceiling
Finish floor elevation Identify the use of each room 36" landing required at the bottom of the stairs
Property lines not provided Windows & Doors 36" landing required at the top of the stairs
Distance from property line to structure Door and window sizes Provide detailed plans for stairs
Structure dimensions
Emergency escape & rescue opening required in Walls
Driveway the basement or two code compliant stairs Sheathing type and thickness
Topography (existing and proposed) (8310.1) Stud size and spacing, species and grade
Footing drain inverts, outlet and separation o
Proposed utilities to be indicated Indicate required light (8 /0 of floor area per room) Sheathing- size, thickness, type
Delineation of flood hazard areas and design flood and ventilation (4% of floor area per room) for Siding, material, type, style - underlayment per
elevation required (11106.1.3) each habitable room or space mfg.
Private sewage disposal system to be identified on Indicate safety glazing in areas required such as: Framing plans
the plan (R106.2.1) doors, windows, tub & shower enclosures, etc. Plans required
Indicate bedroom egress windows (5.7 sf net clear Bearing partitions not identified or unclear
Grading is slope away from the building, opening, 24" clear opening height, 20" clear g p
provide more details Direction of framing
Deck/porch not shown opening width) Beam spans, size, species, grade
Plan must the same submitted and approved Egress window openings
by the Zoning Department and Uncas Health, (if Window and door sill header height sizes Framed Joists -species and grade, size, direction, and
applicable) Window well details spacing
Joists over-spanned
RfvisedAugwt 1, 2005
Town of Montville r
Building Department
Headers over-spanned Ridge beam, rafters are to bear on top of beam or Electrical Plan(s)
Joist hangers for flush framing conditions or bear on ledger strip
ledger Ridge beam supports Plans required
Beams over-spanned Valley rafters - provide engineering data Panel location(s) with main size
Provide design data for all unaligned wall and Valley rafter support Wiring means and method not identified or
floor bearing points. Ventilation - ridge, gable, soffit insufficient
Indicate location of all point loads Provide minimum net ventilation data Meter socket location
Cantilevered framing less than 18" to grade to be Roof sheathing - type Receptacle locations need to be identified
, size, thickness
pressure treated or decay resistant Collar ties -size, placement, spacing GFCI outlet locations need to be identified
Lights and switches need to be identified
Engineering data for steel beams, must be stamped Roof covering - shingles - type, nailing, provide
and signed by a CT registered design professional proper underlayment - show interior horizontal Smoke alarms shall be installed in each sleeping Engineering data for LVL's and similar products distance of double underlayment at eave, etc. room, outside each separate sleeping area in the
Engineering data for I -joists Overhang detail immediate vicinity and on each additional story of
Loadbearing walls not indicated Provide engineering data for all roof trusses - the dwelling, including basements
Design loads not indicated or insufficient: truss drawings must be si Load calculations required
Connecticut ( Licensed Professional and Engisealedneerr) ) a Whirlpool tub/hydromessage tub disconnect Ceiling Plan(s) (required prior to installation) must be designed to location not identified
Plans required ASCE 7-02 Mechanical plan(s)
Ceiling joists - plan required for geometry Decks/Porches Plans required
Ceiling joists - spacing, span, direction, species Plans required Dryer vent
and grade Dimensions required Heating, ventilation, and air conditioning plant
Ceiling joists required to support minimum 30 psf Joists - size, span, spacing, direction, species and locations
live load grade Combustion air requirements
Ceiling joists over-spanned Ledger - show attachment and flashing to house Type of heat (oil, gas, elec)
Decking material and size Heat loss/gain calculations
In utratm offurnace/boiler
Roof Plan(s) Beam- design data if required
Plans required Beams - size, span, spacing, direction, species and Gas Systems
Rafters - pitch, spacing, span, species, and grade grade Plans required
Provide framing details of trayed/vaulted ceilings Posts - size, material, and height LP tank location and size
Provide detail of cathedral ceiling structure and Piers - size, material, depth below grade Trench de th
venting Provide engineering data for the piers to resist Plumbing plan(s)
Indicate connection of lower chord of roof trusses gravity, lateral, shear and uplift loads, stamped and Plans required
and ceiling joists to the top plates and wall studs. signed by a CT licensed design professional Building trap location
Calculate roof tie-down sizes for wind conditions Indicate joist hangers at flush framing and ledger Sewer location
Show framing for gables in cathedral ceiling Stair, handrails, and guardrails details Domestic water location
construction Joists over-spanned Manufacturers data for whirlpools, comer tubs, &
Roof rafters over-spanned larger tubs
Beam over-spanned Water heater size, type, and location
Ridge strapping required Input rating of hot water heater
Ridge beam, engineering data required Height of deck above adjacent grade
Comments:
Building Official
&VisedAugust 1, 2005
Town of Montville
Building Department
310 Norwich-New London Tpke.
Tel. 848-3030, Ext 382 Uncasville; CT 06382 Fax. 848-7231
Residential Building Permit Application Form
Permit # New Construction n Addition n Alteration n Accessory Structure
❑ Single Tamily Two-Tamify n Townhouse
Job Address / 7 Gi4~
(Number) (Street) (Unit)
Job Description A/0-' '
Owner 1?7T , 1- Mailing Address 1
City 61 4J •~'.F t~'i / l r' State CT Zip Tel 2"~
Contractor Mailing Address
City State Zip Tel
Contractor's License/Registration Type & Number Exp. Date
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the
State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee
and that I am authorized to make application for a permit for such work as described above.
Separate applications are required for electrical, plumbin , me tc.
Owner /Agent Signature Date do'~
Construction Value Fee
Building $ $ .
Plumbing $ $
Mechanical $ $
Electrical $ $
Work commencing before the issuance of a permit $
Certificate of Occupancy $
Plan Review $
State Education $
Total $ $
(See gWerse side for additionalrequirements)
Revised''Fe6mary 25 2005
Town
of iYollwlle
Residential Permit Requirements Checklist
This list is to be used as a guide only and is not all-inclusive, additional information may be required for your particular
project. '
Provided AppNot licable Item Provided App Not
1 cable Item
Supporting Documentation Building Section & Details
Completed, signed and dated Building Permit Floor-to-floor heights
Application Material type, size, andspacing
Completed building permit affidavit for property owners Stair details rise, run, treads, nosing, width, headroom)
or sole proprietors or copy of workers compensation Handrail details
insurance Guardrail details
Co of Contractor Re istration or license Roof ventilation
Construction permit sign-off sheet signed by all Framing Plans
departments Design loads - for floors, ceilings, roofs
Documentation showing compliance with the Energy Bearing partitions identified on the plan
Conservation Code www.ener ycodes. ov Direction of framing
Street address of ro'ect on all drawings and documents Sans, beam
Two complete sets of construction documents Woodspecies and grade
Documentation showing compliance with the Framed openings
requirements for construction in 115 h wind zone Wall framing size andspacing identified
Site Plan
Property lines -Sheathing type and thickness
Window and door header sizes
Distance from ro city to structure Decking material, size, spacing
Structure dimensions Engineering data for engineered lumber (LVL's and I-
Drivewa .oists
Topography existin and proposed) Framing plan for engineered lumber
Footing drain inverts, outlet and separation Engineering data for steel beams, signed and sealed by a
Proposed utilities CT registered design professional
Wetlands and flood zone limits and elevation Engineering data for trusses, signed and sealed by a CT
Septic sstem shown and located on the plan registered Professional Engineer
Well and ipin shown and located on the plan Note: Unusual structural conditions may require that
Foundation Information additional en ineerin back u be submitted
Assumed soil bearing pressure Chimneys & Fireplaces
Dimensions Clearances to combustible materials
Wall thickness Manufactures data for metal flues
Footing sizes Exterior fresh air source for fireplaces
Frost protection Flue sizes
Foundation anchor type, size, locations Manufacturers data and installation instructions for
Window and door sizes and locations metal fireplaces
Hatchways Electrical Information
Columns Panel locations with main size
Drainage details Meter socket location
Waterproofing details GFCI outlet locations
Crawl ace ventilation size and location Smoke detector locations
Crawls ace access size and location Lights and switches
Concrete strengths Mechanical Information
Floor Plan Information Dryer vent
Dimensions Bathroom exhaust ventilation (natural or mechanical)
Door and window sizes, egress window type and size
Glazing in hazardous locations Hood exhaust
Garage/dwelling ring rotection Type of heat oil, electric, as
Garage/dwelling separation Heatin, ventilation, and air conditioning plant location
Kitchen layout Oil tank size, location, and piping
Bathroom layouts, tub sizes in gallons, space clearances LP-Gas tank location, size, and piping
Indicate use of all rooms Combustion air requirements
Stair location Manufacturers data forequipment
Attic access location and size Heat loss, Heat gain calculations
Square footage for each habitable level of the structure Plumbing Information
Required light and ventilation for each habitable room Building trap location if on municipal sewer
Elevations
Sewer location
Type of sidin Domestic water location
Roofing Water heater size, type, and location
Other fmishes Manufacturers data for whirlpools, comer tubs, & larger
Finish grades tubs
Building heights
Height of chimney above roof
Roof itch
Wevised rFe&uary 25 2005
Town of Montville
Building Department
File Receipt
484
04-Aug-05 Receipt No:
Date:
Received From: IM Development
Job Address: 14 Allison I's a
Fees Collected State Educational Training Fee
Cash: $0.00
Cash: $0.00
Check: $47.08
Check: $2,676.88
Check No: 7608
$294,274.00
Construction Value:
$0.000
olition Val Val
WDD_
Received By Joseph Summers
NEW RESIDENTIAL PERMIT CALCULATION (2 STORY)
Address: 14 Allisons Way
QTY $/UNIT TOTAL
Living Area 2640 SF $ 61.30 $ 161,832.00
Finished Basement SF $ 20.27 $ -
Unfinished Basement 1320 SF $ 7.67 $ 10,124.40
Kitchen 1 EA $ 9,100.00 $ 9,100.00
Plumbing
Full Bath 2 EA $ 5,000.00 $ 10,000.00
Half Bath 1 EA $ 3,200.00 $ 3,200.00
Garages
Attached, 1 car EA $ 10,775.00 $ -
Attached, 2 car 2 EA $ 18,600.00 $ 37,200.00
Attached, 3 car EA $ 25,810.00 $ -
Detached, 1 car EA $ 13,850.00 $ -
Detached, 2 car EA $ 21,100.00 $ -
Detached, 3 car EA $ 28,350.00 $ -
Under, 1 car EA $ 2,150.00 $ -
Under, 2 car EA $ 3,500.00 $ -
Fireplace & Chimney
Prefab EA $ 4,000.00 $ -
Masonry, exterior EA $ 4,250.00 $ -
Masonry, interior EA $ 4,000.00 $
W/2 fireplaces EA $ 7,500.00 $ -
Decks/Porch es/Su n rooms
Open 120 SF $ 17.17 $ 2,060.40
Covered 288 SF $ 25.52 $ 7,349.76
Enclosed SF $ 123.90 $ -
TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 240,866.56
PERMIT FEE CALCULATIONS
Fee
Building $ 240,867 $ 1,928.00
Plumbing $ 23,285 $ 192.00
Mechanical $ 16,500 $ 136.00
Electrical $ 13,622 $ 112.00
Work Commenced before permit issuance $ -
CO Fee $ 25.00
Plan Review $ 236.80
State Ed Fee $ 294,274 47.08
Total Fees per Residential Unit $ 2,676.88
Based on 2003 RS Means Residential Cost Data
8/4/2005
Town of Montville
Building Department
848-3030, Ext 382
PERMIT SIGN-OFF SHEET
CONST~ION PERMIT APPROVAL
Property Address
Job Description
The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will
be issued until all of the required signatures have been obtained.
Required Department Permit Issuance Approval
Approval
® Tax Collector-
❑ WPCA
Planning & Zoning
Health Department''
-
❑ Department of Public Works
❑ State Dept. of Transportation
❑ Fire Marshal
da
Comments/Conditions:
2?Svised November 1, 2004