Loading...
HomeMy WebLinkAboutSingle Family Residence Plans in File TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2005-0448 Date: 17-Aug-05 Map/Lot: 035/007-000 Owner ID: 59000 Project Location: 14 ALLISON'S WAY Unit: lob Description: Single Family Residence Owner Name: RTT Development Tenant Name: N/A Careof: 35 Blais Road Uncasville CT 06382- Telephone: Contractor Name: Property Owner Telephone: (860)848-2852 DBA: Lic/Reg Type: NHC Lic/Reg No: 1795 Exp Date: 30-Sep-05 Construction Value Permit Fees Construction Information Building Value: $240,867.00 Building Fee: $1,928.00 Use Group: R-4 Plumbing Value: $23,285.00 Plumbing Fee: $192.00 Code: 1999 State Building Code w/2004 Amendment Mechanical Value: $16,500.00 Mechanical Fee: $136.00 Electrical Value: $13,622.00 Electrical Fee: $112.00 Construction Type: 5B Total Value: $294,274.00 Penalty Fee: $0.00 Permit Code: R2 C of O Fee: $25.00 Comments: Plan Review Fee: $236.80 State Ed Fee: $47.08 Total Fee: $2,676.88 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING MECHANICAL ELECTRICAL PERMIT INSPECTIONS FV~ Footing - Prior to pouring concrete R Plumbing and leak test W/ Deck Piers R Electrical F-/~ Backfill - Footing drains and waterproofing ❑d Elec Trench - with conduit installed W Concrete Slab - Prior to pouring concrete ❑ Pool Bonding R Anchor Bolts - with sill plate and prior to floor framing Electrical Service CRS No: 0 Framing R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test FV1 Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑d Insulation ❑ Certifica of Approval d C icate of Occupancy Building Officiars Approval: Town of Montville • Building Department Manufactured Residential Plan Review Form Date: 8 two b i Job Address: ~f / / 1 S o g! `S !d -s Job Description: / • `Ocl a r F R The following information must be included on both sets of plans or accompanying documents (two sets are required) (C.G.S. 29-252a.) This list is offered as a guideline only. It is not meant to be all-inclusive for every permit application, nor is it meant to take the place of the building code. Your application is beine reiected for the followine reason(s) that are checked-off or commented on: Supporting Documentation Retaining Walls Garage Building permit application not completed Plans required Plans required Permit fee $ Documents required to be stamped and signed by a Minimum 5/8" Type X gypsum board separation Permit fee to be alculated CT registered Professional En 'neer (on garage side) to all living spaces - all Worker's comp. Affidavit or worker' comp. Foundation Plan combustible support framing to be covered with Insurance required Plans required minimum 5/8" Type X gypsum board if it supports Copy Contractor's registration or license Dimensions habitable rooms Construction permit sign-off sheet with approvals Wall thickness Openings between the garage and residence required Footing sizes required to have a minimum 13/8" solid wood Provide all documentation to show compliance Column footings - size door, 13/8" solid core steel door, 13/9" with the 2003 International Energy Conservation Frost protection not indicated or insufficient honeycomb core steel door, or 20 minute rated Code (www.enerSYcodes.gov) Foundation - indicate the assumed soil conditions door from the garage to the house and its basement attic Street address of project on all drawings and that the system has been designed for or provide or documents required engineering data. If presumptive soil conditions Indicate self-closing devices on all doors from Field set of approved plans need to be picked up cannot be met, provide soil bearing engineering garage to the house and its basement or attic from our office data Indicate slope for garage floor Two sets of construction documents required, this Concrete strength - foundation, floors, exterior Elevations includes engineering data, calculations, and other porches, walks, slabs Plans required documentation Vapor barrier between sub-grade and concrete Type of siding Wind Limitations Design Criteria basement floor required Type of roofing Submit supporting data to show conformance with Floor thickness and control joint location Finish grades the wind limitations (3 second gust @ 115 mph) Lally column size, attachment and spacing Building heights Design publication needs to be identified (WFCM, Waterproofing details Dimension height of chimney above roof chapter 3, WFCM, chapter 2, ASCE 7-2002) Fireplace/chimney base Roof pitches Documents required to be stamped and signed by a Concrete piers and anchor details Elevations to match site grading CT registered Professional Engineer Foundation drainage Building Section(s) & Details Submit anchoring requirements for the Beam pockets - minimum clearances Plans required manufactured home Engineered foundation plan required Floor-to-floor heights Shearwalls not identified or insufficient Flashing detail - windows and doors - type, Ridge connection not identified or insufficient __Gra paces material Roof-to-wall connection not identified or Crawl space data - clearance to joists, slab Additional sections and details required insufficient thickness (if provided), vapor barrier Fire-resistance rating details required for exterior Wall-to-wall connection not identified or Crawl space ventilation, location, type and size wall(s) insufficient Crawls ace access, location and size Wall/ceiling frreblockin detail Wall-to-sill connection not identified or Floor plan(s) Stairs insufficient Plans required Stair not shown on basement plan Provide engineering data for the piers resist Construction documents shall be of sufficient Riser height not indicated gravity, lateral, shear and uplift loads, stamped and signed by a licensed design professional clarity to indicate the location, nature and extent of Tread depth not indicated Hold-down devices, location and type not the work proposed (11106.1.1) Nosing required for closed risers identified or insufficient Construction documents are to match the Handrail required on at least on side of the stair Foundation anchor spacing not identified or orientation on the site plan reversed plans are not Stair to be minimum 36" in width above the insufficient acceptable, a full plan review can not be handrail height Cold-formed steel framing shall be designed in performed with the submitted documentation Handrails and guardrails - detail, including height accordance with COFS/PM-2001 edition Construction documents are incomplete or un- and maximum opening, handrail cross-section, Site plan clear, a full plan review can not be performed with continuity and required returns the submitted documentation Show minimum headroom in stairways - Plaus required Basement floor plan required measured from nosing plane to lowest point of Plan does not match building plans Dimensions ceiling Finish floor elevation Identify the use of each room 36" landing required at the bottom of the stairs Property lines not provided Windows & Doors 36" landing required at the top of the stairs Distance from property line to structure Door and window sizes Provide detailed plans for stairs Structure dimensions Emergency escape & rescue opening required in Walls Driveway the basement or two code compliant stairs Sheathing type and thickness Topography (existing and proposed) (8310.1) Stud size and spacing, species and grade Footing drain inverts, outlet and separation o Proposed utilities to be indicated Indicate required light (8 /0 of floor area per room) Sheathing- size, thickness, type Delineation of flood hazard areas and design flood and ventilation (4% of floor area per room) for Siding, material, type, style - underlayment per elevation required (11106.1.3) each habitable room or space mfg. Private sewage disposal system to be identified on Indicate safety glazing in areas required such as: Framing plans the plan (R106.2.1) doors, windows, tub & shower enclosures, etc. Plans required Indicate bedroom egress windows (5.7 sf net clear Bearing partitions not identified or unclear Grading is slope away from the building, opening, 24" clear opening height, 20" clear g p provide more details Direction of framing Deck/porch not shown opening width) Beam spans, size, species, grade Plan must the same submitted and approved Egress window openings by the Zoning Department and Uncas Health, (if Window and door sill header height sizes Framed Joists -species and grade, size, direction, and applicable) Window well details spacing Joists over-spanned RfvisedAugwt 1, 2005 Town of Montville r Building Department Headers over-spanned Ridge beam, rafters are to bear on top of beam or Electrical Plan(s) Joist hangers for flush framing conditions or bear on ledger strip ledger Ridge beam supports Plans required Beams over-spanned Valley rafters - provide engineering data Panel location(s) with main size Provide design data for all unaligned wall and Valley rafter support Wiring means and method not identified or floor bearing points. Ventilation - ridge, gable, soffit insufficient Indicate location of all point loads Provide minimum net ventilation data Meter socket location Cantilevered framing less than 18" to grade to be Roof sheathing - type Receptacle locations need to be identified , size, thickness pressure treated or decay resistant Collar ties -size, placement, spacing GFCI outlet locations need to be identified Lights and switches need to be identified Engineering data for steel beams, must be stamped Roof covering - shingles - type, nailing, provide and signed by a CT registered design professional proper underlayment - show interior horizontal Smoke alarms shall be installed in each sleeping Engineering data for LVL's and similar products distance of double underlayment at eave, etc. room, outside each separate sleeping area in the Engineering data for I -joists Overhang detail immediate vicinity and on each additional story of Loadbearing walls not indicated Provide engineering data for all roof trusses - the dwelling, including basements Design loads not indicated or insufficient: truss drawings must be si Load calculations required Connecticut ( Licensed Professional and Engisealedneerr) ) a Whirlpool tub/hydromessage tub disconnect Ceiling Plan(s) (required prior to installation) must be designed to location not identified Plans required ASCE 7-02 Mechanical plan(s) Ceiling joists - plan required for geometry Decks/Porches Plans required Ceiling joists - spacing, span, direction, species Plans required Dryer vent and grade Dimensions required Heating, ventilation, and air conditioning plant Ceiling joists required to support minimum 30 psf Joists - size, span, spacing, direction, species and locations live load grade Combustion air requirements Ceiling joists over-spanned Ledger - show attachment and flashing to house Type of heat (oil, gas, elec) Decking material and size Heat loss/gain calculations In utratm offurnace/boiler Roof Plan(s) Beam- design data if required Plans required Beams - size, span, spacing, direction, species and Gas Systems Rafters - pitch, spacing, span, species, and grade grade Plans required Provide framing details of trayed/vaulted ceilings Posts - size, material, and height LP tank location and size Provide detail of cathedral ceiling structure and Piers - size, material, depth below grade Trench de th venting Provide engineering data for the piers to resist Plumbing plan(s) Indicate connection of lower chord of roof trusses gravity, lateral, shear and uplift loads, stamped and Plans required and ceiling joists to the top plates and wall studs. signed by a CT licensed design professional Building trap location Calculate roof tie-down sizes for wind conditions Indicate joist hangers at flush framing and ledger Sewer location Show framing for gables in cathedral ceiling Stair, handrails, and guardrails details Domestic water location construction Joists over-spanned Manufacturers data for whirlpools, comer tubs, & Roof rafters over-spanned larger tubs Beam over-spanned Water heater size, type, and location Ridge strapping required Input rating of hot water heater Ridge beam, engineering data required Height of deck above adjacent grade Comments: Building Official &VisedAugust 1, 2005 Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 848-3030, Ext 382 Uncasville; CT 06382 Fax. 848-7231 Residential Building Permit Application Form Permit # New Construction n Addition n Alteration n Accessory Structure ❑ Single Tamily Two-Tamify n Townhouse Job Address / 7 Gi4~ (Number) (Street) (Unit) Job Description A/0-' ' Owner 1?7T , 1- Mailing Address 1 City 61 4J •~'.F t~'i / l r' State CT Zip Tel 2"~ Contractor Mailing Address City State Zip Tel Contractor's License/Registration Type & Number Exp. Date I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. Separate applications are required for electrical, plumbin , me tc. Owner /Agent Signature Date do'~ Construction Value Fee Building $ $ . Plumbing $ $ Mechanical $ $ Electrical $ $ Work commencing before the issuance of a permit $ Certificate of Occupancy $ Plan Review $ State Education $ Total $ $ (See gWerse side for additionalrequirements) Revised''Fe6mary 25 2005 Town of iYollwlle Residential Permit Requirements Checklist This list is to be used as a guide only and is not all-inclusive, additional information may be required for your particular project. ' Provided AppNot licable Item Provided App Not 1 cable Item Supporting Documentation Building Section & Details Completed, signed and dated Building Permit Floor-to-floor heights Application Material type, size, andspacing Completed building permit affidavit for property owners Stair details rise, run, treads, nosing, width, headroom) or sole proprietors or copy of workers compensation Handrail details insurance Guardrail details Co of Contractor Re istration or license Roof ventilation Construction permit sign-off sheet signed by all Framing Plans departments Design loads - for floors, ceilings, roofs Documentation showing compliance with the Energy Bearing partitions identified on the plan Conservation Code www.ener ycodes. ov Direction of framing Street address of ro'ect on all drawings and documents Sans, beam Two complete sets of construction documents Woodspecies and grade Documentation showing compliance with the Framed openings requirements for construction in 115 h wind zone Wall framing size andspacing identified Site Plan Property lines -Sheathing type and thickness Window and door header sizes Distance from ro city to structure Decking material, size, spacing Structure dimensions Engineering data for engineered lumber (LVL's and I- Drivewa .oists Topography existin and proposed) Framing plan for engineered lumber Footing drain inverts, outlet and separation Engineering data for steel beams, signed and sealed by a Proposed utilities CT registered design professional Wetlands and flood zone limits and elevation Engineering data for trusses, signed and sealed by a CT Septic sstem shown and located on the plan registered Professional Engineer Well and ipin shown and located on the plan Note: Unusual structural conditions may require that Foundation Information additional en ineerin back u be submitted Assumed soil bearing pressure Chimneys & Fireplaces Dimensions Clearances to combustible materials Wall thickness Manufactures data for metal flues Footing sizes Exterior fresh air source for fireplaces Frost protection Flue sizes Foundation anchor type, size, locations Manufacturers data and installation instructions for Window and door sizes and locations metal fireplaces Hatchways Electrical Information Columns Panel locations with main size Drainage details Meter socket location Waterproofing details GFCI outlet locations Crawl ace ventilation size and location Smoke detector locations Crawls ace access size and location Lights and switches Concrete strengths Mechanical Information Floor Plan Information Dryer vent Dimensions Bathroom exhaust ventilation (natural or mechanical) Door and window sizes, egress window type and size Glazing in hazardous locations Hood exhaust Garage/dwelling ring rotection Type of heat oil, electric, as Garage/dwelling separation Heatin, ventilation, and air conditioning plant location Kitchen layout Oil tank size, location, and piping Bathroom layouts, tub sizes in gallons, space clearances LP-Gas tank location, size, and piping Indicate use of all rooms Combustion air requirements Stair location Manufacturers data forequipment Attic access location and size Heat loss, Heat gain calculations Square footage for each habitable level of the structure Plumbing Information Required light and ventilation for each habitable room Building trap location if on municipal sewer Elevations Sewer location Type of sidin Domestic water location Roofing Water heater size, type, and location Other fmishes Manufacturers data for whirlpools, comer tubs, & larger Finish grades tubs Building heights Height of chimney above roof Roof itch Wevised rFe&uary 25 2005 Town of Montville Building Department File Receipt 484 04-Aug-05 Receipt No: Date: Received From: IM Development Job Address: 14 Allison I's a Fees Collected State Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $47.08 Check: $2,676.88 Check No: 7608 $294,274.00 Construction Value: $0.000 olition Val Val WDD_ Received By Joseph Summers NEW RESIDENTIAL PERMIT CALCULATION (2 STORY) Address: 14 Allisons Way QTY $/UNIT TOTAL Living Area 2640 SF $ 61.30 $ 161,832.00 Finished Basement SF $ 20.27 $ - Unfinished Basement 1320 SF $ 7.67 $ 10,124.40 Kitchen 1 EA $ 9,100.00 $ 9,100.00 Plumbing Full Bath 2 EA $ 5,000.00 $ 10,000.00 Half Bath 1 EA $ 3,200.00 $ 3,200.00 Garages Attached, 1 car EA $ 10,775.00 $ - Attached, 2 car 2 EA $ 18,600.00 $ 37,200.00 Attached, 3 car EA $ 25,810.00 $ - Detached, 1 car EA $ 13,850.00 $ - Detached, 2 car EA $ 21,100.00 $ - Detached, 3 car EA $ 28,350.00 $ - Under, 1 car EA $ 2,150.00 $ - Under, 2 car EA $ 3,500.00 $ - Fireplace & Chimney Prefab EA $ 4,000.00 $ - Masonry, exterior EA $ 4,250.00 $ - Masonry, interior EA $ 4,000.00 $ W/2 fireplaces EA $ 7,500.00 $ - Decks/Porch es/Su n rooms Open 120 SF $ 17.17 $ 2,060.40 Covered 288 SF $ 25.52 $ 7,349.76 Enclosed SF $ 123.90 $ - TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 240,866.56 PERMIT FEE CALCULATIONS Fee Building $ 240,867 $ 1,928.00 Plumbing $ 23,285 $ 192.00 Mechanical $ 16,500 $ 136.00 Electrical $ 13,622 $ 112.00 Work Commenced before permit issuance $ - CO Fee $ 25.00 Plan Review $ 236.80 State Ed Fee $ 294,274 47.08 Total Fees per Residential Unit $ 2,676.88 Based on 2003 RS Means Residential Cost Data 8/4/2005 Town of Montville Building Department 848-3030, Ext 382 PERMIT SIGN-OFF SHEET CONST~ION PERMIT APPROVAL Property Address Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Department Permit Issuance Approval Approval ® Tax Collector- ❑ WPCA Planning & Zoning Health Department'' - ❑ Department of Public Works ❑ State Dept. of Transportation ❑ Fire Marshal da Comments/Conditions: 2?Svised November 1, 2004