Date: 1-91 /,06 Field Inspection Notice Permit
Address: / Ace J
Not Comments/Corrections Required - re-mspection required:
Inspection Approved Approved
Footing ❑ #
[A Backfill El
' `'Concrete Slab ❑
❑ Framing ❑ ❑
❑ Rough Elec ❑ ❑
❑ Elec Service ❑ ❑
❑ Rough HVAC ❑ ❑
❑ Rough Plumbing ❑ ❑
❑ Gas Line ❑ ❑
❑ Fireplace Throat ❑ ❑
❑ Chimney ❑ ❑ M
❑ Fire/Draftstopping ❑ ❑
❑ Insulation ❑ ❑
❑ Final Inspection ❑ ❑
❑ C of o ❑ ❑
❑ ❑
Inspector's Signature 6/7
Town of Montville
Building Department
Date: !:2 A-3 Field Inspection Notice Permit
Address: ~h3S
Not Comments/Corrections Required - re-inspection required:
Inspection Approved Approved
k AFooting ❑
❑ Backfill ❑
❑ Concrete Slab ❑ ❑
❑ Framing ❑ ' ❑
❑ Rough Elec ❑ ❑
❑ Elec Service ❑ ❑
❑ Rough HVAC ❑ ❑
❑ Rough Plumbing ❑ ❑
Gas. Line ❑ ❑
❑ Fireplace Throat ❑
❑ Chimney El F1
❑ Fire/Draftstopping ❑ ❑
❑ Insulation ❑ ❑
❑ Final Inspection ❑ ❑
❑ Cof0 ❑ ❑ .
eto s Signatur
Town of Montville
BUILDING DEPARTMENT
310 Norwich-New London Turnpike
Uncasville, CT 06382
(860) 848-3030, Ext. 382
Building Permit
Permit Number: 62004-0084 Date: 16-Mar-04 Map/Lot: 043/009-018 Owner ID 1753
Job Location: J -ALLISON'S WAY Unit
Job Description: SFR
Owner: Contractor:
RTT Development RTT Development
35 Blais Road
35 Blais Road Uncasville Ct. 06382-
Uncasville CT 06382 Telephone: (860) 889-1662
Lic/Reg Type/No. NHC 1795 Exp Date: 30-Sep-05
Tenant:
Self
Telephone:
Construction Values Permit Fees Construction Information
Building Value: $224,931.00 Building Fee: $1,348.00 Use Group: R4
Plumbing Value: $15,100.00 Plumbing Fee: $94.00 Code: 1995 CABO
Mechanical Value: $16,778.00 Mechanical Fee: $100.00 Construction Type: 5B
Electrical Value: $15,459.00 Electrical Fee: $94.00 Permit Code: R2
Other Value: $0.00 Other Fee: $0.00 Comments:
Total Value: $272,268.00 CO Fee: $10.00
Plan Review Fee: $134.80
State Ed Fee: $43.56
Total Fees: $1,824.36
It is the owners responsibility to schedule the following inspections (minimum 48 hours notice required)-
Footing - Prior to pouring concrete 0 Rough HVAC
Backfill - Footing drains and waterproofing ❑ Fireplace Throat
Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble
Rough Framing W Firestopping/draftstopping
❑d Rough Electrical ❑ Insulation
Electrical Service CRS ❑ Final Inspection
d❑ Rough plumbing and leak test Certificate of Occupany
Gas piping and test
Building Official's Signature.
Town of Montville
Plan Review Form
Date: M A2C A » Zero 0
Street Address: A L.LISvIJ1-sue
Job Description: ,/J6-(,i -5-F42-
We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute
29-263, your application is being rejected for the following reason(s) that are checked-off or commented on:
• Supporting Documentation
Plans are to be drawn to scale including dimensions of rooms and spaces and all framing information
Building permit application not completed, signed, dated
Permit fee $
Worker's comp. Affidavit or worker' comp. Insurance
Copy Contractor's registration or license
Construction permit sign-off sheet
Street address of project on all drawings and documents
Field set of approved plans need to be picked up from our office
Comments: 0 ye-rd2 Gam' /JfZ./JC~ l3 IJS~ A/ic) OoLi ,ACCle.S1"mo C.
e
clal
Town of Montville
Residential Plan Review
Date: 9) ~c~o3
Job Address: -7 1~~ (y f C, r J f Job Description: A)o 6✓- s~j L
We have received a building permit application for the above referenced property. In accordance with Connecticut General
Statute 29-263, your application is being rejected for the following reason(s) that are checked-off or commented on:
• Supporting Documentation Access 18"x24" (409.2)
Plans are to be drawn to scale including dimensions of rooms and
spaces and all framing information (112.1) • Floor plan(s)
Building permit application not completed, signed, dated Plans required
r-J Permit fee $ -TO %31r %C vf.o-TiXD Dimensions
Worker's comp. Affidavit or worker' comp. Insurance Finish floor elevation
Copy Contractor's registration or license Minimum room sizes (304.1)
_ Construction permit sign-off sheet Door and window sizes
Provide all documentation to show compliance with the Model Kitchen layout
Energy Code (1995 MEC). Contact your insulation contractor, Bathroom layouts, tub sizes in gallons, space clearances
Northeast Smart Living Center (1-800-228-7764) or your local Stair location (min. width 36") (311.1)
building official for information. Attic access location and size
Street address of project on all drawings and documents Identify the use of each room
Total square footage for each level of the structure
• Site plan Indicate required light (8% of floor area per room) and ventilation
Plans required (4% of floor area per room) for each habitable room or space (303. 1.)
Finish floor elevation Indicate safety glazing in areas required such as: doors, windows, tub
Signed by P&7-, Wetlands, Uncas health, WPCA & shower enclosures, etc. (308.4.)
Property lines not provided Indicate bedroom egress windows (5.7 sf net clear opening, 24" clear
Distance from property to structure opening height, 20" clear opening width) (310.2.1.)
Structure dimensions Egress window maximum sill height 44" (310.2)
Driveway Are basement stairs enclosed/accessible? If so, protect with
Topography (existing and proposed) minimum Y2" sheetrock (310.3.)
Footing drain inverts, outlet and separation Designate which door is the required exit (36" minimum, hinged)
Proposed utilities Garage
Wetlands and flood zone limits and elevations Minimum 5/8" Type X gypsum board separation (on garage side) to
all living spaces - all combustible support framing to be covered with
minimum 5/8" Type X gypsum board if it supports habitable rooms
• Foundation Plan (309.2)
Plans required Indicate minimum 1 solid wood door, 1 solid core steel door, 1
Dimensions honeycomb core steel door, or 20 minute rated door from the
Wall thickness garage to the house and its basement or attic (309.1)
Footing sizes Indicate self-closing devices on all doors from garage to the house
Frost protection required and its basement or attic (309.1)
Window and door sizes and locations Indicate slope for garage floor (309.3.)
Hatchway
Foundation - indicate the assumed soil conditions that the system has • Elevations
been designed for or provide engineering data. If presumptive soil Plans required
conditions cannot be met, provide soil bearing engineering data (401) Type of siding
Concrete strength - foundation, floors, exterior porches, walks, slabs
(402.2) Type of roofing
finishes
Basement-finished of unfinished? Other Finish grades
Vapor barrier between sub-grade and concrete basement floor
(505.2.3) Building heights Minimum height of foundation walls above finished grade (404.1.3) Dimension height of chimney above roof
Roof pitches
Perimeter insulation, if conditioned space
Anchor bolts - size and location (403.1.a)
Floor thickness and control joint location (403. La) • Building Section(s) & Details
Lally column size, attachment and spacing (408) Plans required
Column footings - size (403) Floor-to-floor heights
Waterproofing details (406) Handrails and guardrails - detail, including height and maximum
Rebar if required - wall length, unbalanced fill, or soil conditions will opening, handrail cross-section, continuity and required returns
determine this. Provide engineering data for complex design. Riser height (8 max), tread depth (9" min.), and nosing (3/4" - 1
Fireplace/chimney base Concrete piers and anchor details - decks Show minimum headroom in stairways - 6'-8" measured from nosing
Foundation drainage - sump, drain to grade, or town storm system; plane to lowest point of ceiling
indicate pitch (405.1) Stud size and spacing, species and grade (or minimum Fb and E)
Beam pockets - minimum clearances Sheathing - size, thickness, type
Crawl Spaces Siding, material, type, style - underlayment per mfg.
Crawl space data - clearance to joists, slab thickness (if provided), Insulation - R-value, type - including basement walls if applicable
vapor barrier (409) Flashing detail - windows and doors - type, material
Ventilation (409.1)
Town of Montville
IRW
• Framing plans Decks/Porches
Plans required _~;A, Plans required UYJGL
Bearing partitions Joists - size, span, spacing, direction, species and grade (or minimum
Direction of framing Fb and E)
Beam spans, size, species, grade Ledger - show attachment and flashing to house
Framed openings Decking material and size
Sheathing type and thickness Beam - design data if required
Window and door header sizes Posts - size, material, and height
Joists - species and grade (minimum Fb and E), size, direction, and Piers - size, material, depth below grade (minimum 42" required)
Indicate joist hangers at flush framing and ledger
spacing
Joists over-spanned Stairs, handrails, and guardrails
_ Headers/beams overspanned ('n 7-iC1"t. <,AG'-OCR
Double joists at parallel bearing partitions, bathtubs, etc. (502.3.2) • Chimneys and Fireplaces
Details of framing for plumbing, such as headers and trimmers at Indicate clearance of masonry to combustible framing materials and
traps, etc. clearance from fireplace opening to finished trim
Joist hangers for flush framing conditions or ledger (502.4.2) Show data for mechanical flue sizing
Deck material, type, size, and span Show exterior combustion air source
Floor insulation - R-value, type, vapor barrier location Flue sizes
Provide design data for all unaligned wall and floor bearing points. Manufactures data and installation instructions for metal fireplaces
Indicate location of all point loads
Cantilevered framing less than 18" to grade to be pressure treated or . Electrical Plan(s)
decay resistant Plan(s) required
Engineering data for steel beams, engineered lumber, roof trusses or Panel location(s) with main size
any other engineered product or design
Roofs/ceilings Meter socket location
Outlet locations
Provide roof framing plan for roof geometry GFCI outlet locations
Ceiling joists - spacing, span, direction, species and grade (or
minimum Fb and E) Lights and switches
circuits
Rafters - pitch, spacing, span, species, and grade (or minimum Fb Appliance/equipment
and E) Stair illumination Insulation - R-value, type -including basement walls if applicable Stairway light activation at both top and bottom of stair (303.4) Ventilation - ridge, gable, sof Show required AC/DC smoke detectors (316)
fit
Provide minimum net ventilation data
Attic access (22"00" minimum) for any attic with 30" or more clear • Mechanical plan(s)
height Pplan(s) required
Roof sheathing -type, size, thickness Dryer vent
Collar ties - size, placement, spacing Bathroom exhaust ventilation (natural or mechanical) type and size
Roof covering - shingles - type, nailing, provide proper with calculations
underlayment - show interior horizontal distance of double Hood exhaust
underlayment at eave, etc. Type of heat
Overhang detail Heating, ventilation, and air conditioning plant locations
Provide framing details of trayed/vaulted ceilings Oil/LP-gas tank size, location and piping
Provide detail of cathedral ceiling structure and venting Make-up air requirements
Indicate connection of lower chord of roof trusses and ceiling joists to Manufactures data for equipment
the top plates of interior and exterior walls. Calculate roof tie-down Heat loss/gain calculations
sizes when required by wind conditions
Show framing for gables in cathedral ceiling construction . Plumbing plan(s)
Provide engineering data for all roof trusses - (truss drawings must be plan(s) required
signed and sealed by a Connecticut Licensed Professional Engineer) Building trap location
Roof rafters over-spanned
Ceiling joists over-spanned Sewer location
Domestic water location
Manufacturers data for whirlpools, corner tubs, & larger tubs
Water heater size, type, and location
Comments: ~i.✓l~T i~®~!~% n tJ~ rr C~l~.6~ Cam, c _~fJ C~a l US r3<a t-v~ ~3- L,b t✓ ll3~S z~h
Oficial
Town of Montville G
i F Building Department' Permit # l
310 Norwich-New London Tpke.
Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax.. 848-7231
One & Two Family Building Permit Application Form
❑ New Construction n Addition ❑ A(teration Accessory Structure
Other
Job.Location
Job Description/Materials
Owner s Mailing Address 3 5' A'J ~i
City C/ih c/~ s 1,1& State GT' Zip 06 3 Tel
Contractor } 1 Mailing Address
City + State Zip Tel
Contractor's License/Registration Type & Number Exp. Date
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the
State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee
and that I am authorized to make application for a permit for such Work as described above.
Owner /Agent Signature Date / 3
Construction Value Fee
Building $ $
Plumbing $ $
Mechanical $ $
Electrical $ $
Other $ - - $
Certificate of Occupancy $
Plan Review Fee $
State Education $
Total $ $
(See Reverse side for additiona(requirements)
Town of Montville
Residential Permit Requirements ,
❑ Two (2) complete sets of construction documents (to scale) are required and shall show the following information if
applicable. This list is not all-inclusive, additional information may be required for your particular project.
• Supporting Documentation • Building Section(s) & Details
Completed signed and dated Building Permit Application Floor-to-floor heights
Permit fee - calculated upon completion of plan review Material type, size, and spacing
Completed building permit affidavit for property owners or sole Stair details (rise, run, treads, nosing, width, headroom)
proprietors or copy of workers compensation insurance Handrail details
Copy of Contractor Registration or license Guardrail details
Construction permit sign-off sheet signed by all departments Roof ventilation
Model Energy Code Analysis
Heat loss calculations • Framing plans
Engineering data for steel beams, engineered lumber, roof trusses or any Design loads - for floors, ceilings, roofs
other engineered products or design
Street address of project on all drawings and documents Bearing partitions
Direction of framing
Spans, beam
• Site plan Wood species and grade
Property lines Framed openings
Distance from property to structure Sheathing type and thickness
Structure dimensions Window and door header sizes
Driveway Decking material, size, spacing
Topography (existing and proposed) Note: Unusual structural conditions may require that additional
Footing drain inverts, outlet and separation engineering back up be submitted
Proposed utilities
Wetlands and flood zone limits and elevation • Chimneys and Fireplaces
Signed by P & Z, Wetlands, Uncas Health, WPCA Clearances to combustible materials
• Foundation Plan Manufactures data for metal flues
Exterior fresh air source for fireplaces
Assumed soil bearing pressure Flue sizes
Dimensions Manufacturers data and installation instructions for metal fireplaces
Wall thickness
Footing sizes • Electrical Plan(s)
Anchor bolts, size and spacing
Window and door sizes and locations Panel location(s) with main size
Hatchways Meter socket location
Columns Outlet locations
Floor construction data GFCI outlet locations
Drainage details Smoke detector locations
Waterproofing details Lights and switches
Crawl space ventilation Appliance/equipment circuits
on
Crawl space access Stair illumination
Concrete strengths • Mechanical plan(s)
• Floor plan(s) Dryer vent
Dimensions Bathroom exhaust ventilation (natural or mechanical) type and size
Hood exhaust
Door and window sizes, egress window Type of heat
Glazing in hazardous locations
GazageJdwelling opening protection Heating, ventilation, and air conditioning plant location
Garagddwelling separation Oil tank size, location, and piping
Kitchen layout LP-Gas tank location, size, and piping
Bathroom layouts, tub sizes in gallons, space clearances Make-air requirements
Indicate use of all rooms Manufacturers data for equipment
Stair location
Attic access location and size • Plumbing plan(s)
Square footage for each habitable level of the structure Building trap location if on municipal sewer
Required light and ventilation for each habitable room Sewer location
Domestic water location
• Elevations - minimum of two required Manufacturers data for whirlpools, corner tubs, & larger tubs
Type of siding Water heater size, type, and location
Roofing
Other Finish grades Note: One set of approved plans is required to be kept on
Building heights site at all times.
Height of chimney above roof
Roof pitch
Town of'ontville Building Departm- t Receipt
Dated 1,1_5 /off No. 03433
From :'-Vt~ n o
Job Address: ~,)j
Amount $ mil, Cash C eck Check #
Circle one)
Received by Permit #
Permit Fee Calculation Spreadsheet
RESIDENTIAL PERMIT CALCULATION (2 STORY)
House Construction A_ (E=Economy, A=Average, C=Custom)
OTI" $/UNIT $/UNIT $/UNIT TOTAL
Living Area _ X996 SF $ - $ 72.08 $ - $ 215,951.68
Finished Basement SF $ $ 16.01 $ - S
Unfinished Basement 11- 10 SF $ - $ 5.41 $ - S 6,546.10
Kitchen 1 EA $ - S - $ $ _
Plumbing
Full Bath 2 EA $ _ $ 4,229.40 $ S 4,229.40
Half Bath - 1_ EA $ $ 2,691.15 $ $ 2,691.15
Garages
Attached, 1 car EA $ - $ 8,885.10 $ $
Attached, 2 car 1 EA $ - $ 15,113.70 $ $ 15,113.70
Attached, 3 car EA $ $ 20,913.90 $ $ -
Detached, 1 car EA $ - $ 11,657.10 $ - S -
Detached, 2 car EA $ - $ 17,456.25 $ - $ -
Detached, 3 car EA $ - $ 23,256.45 $ - $
Under, 1 car EA $ - $ 1,304.10 $ - S -
Under, 2 car EA $ - $ 1,757.70 $ - $ -
Fireplace & Chimney
Prefab EA $ - $ 3,963.75 $ - S -
Masonry, exterior EA $ - $ 3,963.75 $ - $
Masonry, interior EA $ - $ 3,701.25 $ - S -
W/2 fireplaces EA $ - $ 6,746.25 $ S -
Breezeway/Decks
Open '120 SF $ - $ 22.31 $ $ 2,677.20
Enclosed -SF $ - $ 94.76 S $ -
Porches
Open 3 l SF $ - $ 62.69 $ $ 16,550.16
Enclosed SF $ - $ 123.90 S - $
Heating Adjustment 2996 SF $ - $ (2.76) $ S (8,268.96)
Air Conditioning 2996 SF $ - $ 2.84 $ - $
Electrical 2996 SF $ - $ (5.16) $ - $ (15,459..36)
Plumbing 2996 SF $ - $ (5.04) $ - $ (15,099.84)
TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 224,931.23
Y Is air conditioning included (Y/N)? 8.509
PERMIT FEE
Building $ 224,931 $ 1,348,00
Y Plumbing $ 15,100 $ 94.00
Y Mechanical S 16,778 $ 100.00
Y Electrical S 15.499 $ 94,00
Other
CO Fee S 10,00
Plan Review $ 134,80
State Ed Fee $ 272;268 $ 43.56
Total Fees $ 1,824,36
Based on 2003 RS Means REsidential Cost Data
12/15/03
NEW HOME CONSTRUCTION CONTRACTOR
RTI`DEVELOPMENT
35 BLAIS RD
UNCASVILLE, CT 06382
LIC./REG NO. EFFECTIVE EXPIRES
R 95 10/01/2003 09 /2005
SIGNED
A.
STATE OF CONNECTICUT
WORKERS' COMPENSATION COMMISSION
Building Permit Affidavit for Property Owners or Sole Propri
etors
(Conn. Gen. Stat. § 31-286b)
Property located at:
In the town of
Name of building permit applicant: eYTT
Please check one:
1. k I am the owner of the above property.
2. I am the sole proprietor of a business.
2A. Name of business:
213. Federal Employer Identification Number (FEIN)
- - - -
Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or
principal employer" may provide either a certificate of workers' compensation insurance or a "sworn
affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the
job site in accordance with this chapter."
Please check one:
1. I do not intend to act as a general contractor or principal employer.
[Sign and stop here]
Signature of applicant
2._ I intend to act as a general contractor or principal employer. Applicant must either provide a
certificate of workers' compensation insurance or sign the affidavit below.
- - - - -
Affidavit
I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor,
subcontractor, or other worker before he/she engages in work on the above property in accordance with the
Workers' Compensation Act (Chapter 568).
I understand that pursuant to § 31-275 C.G.S., officers of a corporati partners in a partnership may elect
to be excluded from coverage by filing a waiver with the aPp Dis ct Office; and that a sole proprietor
of a business is not required to have coverage unles e fil tent t accept coverage.
Signature of applicant
Subscribed and sworn to before me this day of i~0 , 200 3.
C`~ (Notary Public/Commissioner of the Superior Court)
MELaIN DA L. ROBERTS
NOTARY PUBLIC
My COMMISSION EXPIRES OCT. 31, 2007
Town of Montville
Building Department
848-3030, Ext 382
ONE & TWO FAMH.Y
CONSTRUCTION PERMIT
SIGN-OFF SHEET
Property Address
Job Description: G~1 ~rcdC 2 Xis. /C
The owner/agent shall be responsible for the completion of the form, no certificate of occupancy will be issued until all
signatures below have been obtained.
HEALTH DISTRICT 848-3030-339
Approved Not Permit
Permit Z _ ❑ Required
SDate
Approved Not Permit
❑ Permit ❑ Required
Private Well Date
WPCA DEPARTMENT 848-3030, Ext 376
Approved Not Permit
❑ Permit ❑ Required
Municipal Sewer Date
House Trap ❑ Outside ❑ Inside
Approved Not Permit
❑ Permit # ❑ Required
Municipal Water Date
DEPARTMENT OF PUBLIC WORKS 848-7473
Approved Not Permit
Permit #;R, 6 ❑ Required
Date
PL NNING & ZONING DEPARTMENT 848-3030. Ext. 379
_ Approved Not Permit
p Permit ',70Ej Required
Zoning ate
Approved Not Permit
❑ Permit ❑ Required
Inland-Wetlands Date