HomeMy WebLinkAboutSingle Family Residence Plans in File TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2004-0556 Date: 01-Sep-04 Map/Lot: 043/009-017 Owner ID: 52000 Project Location: 5 ALLISON'S WAY Unit: lob Description: Single Family Residence Owner Name: RTT Development Tenant Name: N/A Careof: 35 Blais Road Uncasville CT 06382- Telephone: Contractor Name: Property Owner Telephone: (860)889-1662 DBA: Lic/Reg Type: NHC Lic/Reg No: 1795 Exp~aEe:. 30-Sep-05 Construction Value Permit Fees Construction Information Building Value: $177,386.00 Building Fee: $1,424.00 Use Group: R-4 Plumbing Value: $11,088.00 Plumbing Fee: $96.00 Code: 1999 State Building Code Mechanical Value: $12,320.00 Mechanical Fee: $104.00 w/2000 Amendment Electrical Value: $11,352.00 Electrical Fee: $96.00 Construction Type: 5B Total Value: $212,146.00 Penalty Fee: $0.00 Permit Code: R2 C of O Fee: $25.00 Comments: Plan Review Fee: $172.00 State Ed Fee: $33.94 Total Fee: $1,950.94 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. W Footing - Prior to pouring concrete R Plumbing and leak test W] Backfill - Footing drains and waterproofing R Electrical Wl Concrete Slab - Prior to pouring concrete Q Elec Trench - with conduit installed Framing Q Electrical Service CRS No: 0 ❑ Fireplace Throat - One flue above throat ❑d R HVAC ❑ Chimney - One flue above thimble Gas Piping and leak test W Firestop Draftstopping ❑ Final Inspection F,V-1 Insulation 0 Certificate of Occupancy Building Official's Approval: Town of Montville Residential Plan Review Date: C9 iJ Z Zcoo y Job Address: AG&J-,C7 FJ's Job Description: AJ676'' J~~--' We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute 29-263, your application is being reiected for the following-reason(s) that are checked-off or commented on: • Supporting Documentation Crawl Spaces Plans are to be drawn' to scale including dimensions of rooms and Crawl space data - clearance to joists, slab thickness (if provided), spaces and all framing information (112.1) vapor barrier (409) Building permit application not completed, signed, and/or dated Ventilation (409.1) Permit fee $ Access 18"x24" (409.2) ~~Permit fee to be calculated Worker's comp. Affidavit or worker' comp. Insurance • Floor plan(s) _ _Copy Contractor's registration or license Plans required Construction permit sign-off sheet Dimensions Provide all documentation, to show compliance with the Model Finish floor elevation Energy Code (1995 MEC). Minimum room sizes (304.1) Street address of project on all drawings and documents required Door and window sizes Field set of approved plans need to be picked up from our office Kitchen layout Two sets of construction documents required Bathroom layouts, tub sizes in gallons, space clearances Stair location (min. width 36") (311.1) • Site plan Attic access location and size Identify the use of each room Plans required Indicate required light (8% of floor area p er r oom) and v entilation Finish floor elevation (4% of floor area per room) for each habitable room or space (303.1.) Property lines not provided Indicate safety glazing in areas required such as: doors, windows, tub Distance from property to structure Structure dimensions & shower enclosures, etc. (308.4.) Indicate bedroom egress windows (5.7 sf net clear opening, 24" clear Driveway opening height, 20" clear opening width) (310.2.1.) Topography (existing and proposed) Egress window maximum sill height 44" (310.2) Footing drain inverts, outlet and separation Are basement stairs enclosed/accessible? (310.3.) Proposed utilities Designate which door is the required exit (36" minimum, hinged) Wetlands and flood zone limits and elevations Garage Minimum 518" Type X gypsum board separation (on garage side) to • Foundation Plan all living spaces - all combustible support framing to be covered with Plans required minimum 5/8" Type X gypsum board if it supports habitable rooms Dimensions (309.2) . Wall thickness Indicate minimum 1'/1' solid wood door, 1 '/1' solid core steel door, 1 Footing sizes honeycomb core steel door, or 20 minute rated door from the Frost protection required garage to the house and its basement or attic (309.1) Window and door sizes and locations Indicate self-closing devices on all doors from garage to the house Hatchway and its basement or attic (309.1) Foundation - indicate the assumed soil conditions that the system has Indicate slope for garage floor (309.3.) been designed for or provide engineering data. If presumptive soil conditions cannot be met, provide soil bearing engineering data (401) • Elevations Concrete strength - foundation, floors, exterior porches, walks, slabs Plans required (402.2) Basement - finished of unfinished? Type of siding vapor barrier between sub-grade and concrete basement floor Type of roofing (505.2.3) Other finishes Minimum height of foundation walls above finished grade (404.1.3) Finish grades . Perimeter insulation, if conditioned space Building heights Anchor bolts -size and location (403.1.x) Dimension height of chimney above roof Roof pitches Floor thickness and control joint location (403. La) Lally column size, attachment and spacing (408) Column footings - size (403) • Building Section(s) & Details Waterproofing details (406) Plans required Rebar if required - wall length, unbalanced fill, or soil conditions will Floor-to-floor heights determine this. Provide engineering data for complex design. Handrails and guardrails - detail, including height and maximum Fireplace/chimney base opening, handrail cross-section, continuity and required returns Concrete piers and anchor details - decks Riser height (8 max), tread depth (9" min.), and nosing (3/4" - 1 Foundation drainage - sump, drain to grade, or town storm system; %'D indicate pitch (405.1) Show minimum headroom in stairways - 6'-8" measured from nosing Beam pockets - minimum clearances plane to lowest point of ceiling Stud size and spacing, species and grade (or minimum Fb and E) Sheathing - size, thickness, type Siding, material, type, style - underlayment per mfg. Flashing detail - windows and doors - type, material Town of.MonMlle Decks/Porches • Framing plans Plans required Plans required Joists - size, span, spacing, direction, species and grade (or minimum Bearing partitions Fb and E) Direction of framing Ledger - show attachment and flashing to house Beam spans, size, species, grade Decking material and size Framed openings Beam - design data if required Sheathing type and thickness Posts - size, material, and height Window and door header sizes Piers - size, material, depth below grade (minimum 42" required) Joists - species and grade (minimum Fb and E), size, direction, and Indicate joist hangers at flush framing and ledger spacing Stairs, handrails, and guardrails Joists over-spanned Headers/beams overspanned • Chimneys and Fireplaces Double joists at parallel bearing partitions, bathtubs, etc. (502.3.2) Indicate clearance of masonry to combustible framing materials and Details of framing for plumbing, such as headers and trimmers at clearance from fireplace opening to finished trim traps, etc. Show data for mechanical flue sizing Joist hangers for flush framing conditions or ledger (502.4.2) Show exterior combustion air source Deck material, type, size, and span Flue sizes Floor insulation - R-value, type, vapor barrier location Manufactures data and installation instructions for metal fireplaces Provide design data for all unaligned wall and floor bearing points. Indicate location of all point loads • Electrical Plan(s) Cantilevered framing less than 18" to grade to be pressure treated or Plan(s) required decay resistant Panel location(s) with main size Engineering data for steel beams, engineered lumber, roof trusses or Meter socket location any other engineered product or design Outlet locations Roofs/ceilings GFCI outlet locations Provide roof framing plan for roof geometry Ceiling joists - spacing, span, direction, species and grade (or Lights and switches minimum Fb and E) Appliance/equipment circuits _Rafters- pitch, spacing, span, species and grade Stair illumination and E (or minimum Fb Stairway light activation at both top and bottom of stair (303.4) hisulation - R-value, type - including basement walls if applicable Show required AC/DC smoke detectors (316) Ventilation - ridge, gable, soffit Provide minimum net ventilation data • Mechanical plan(s) Attic access (22"00" minimum) for any attic with 30" or more clear Plan(s) required height Dryer vent Roof sheathing = type, size, thickness Bathroom exhaust ventilation (natural or mechanical) type and size Collar ties - size, placement, spacing with calculations Roof covering - shingles - type, nailing, provide proper Hood exhaust underlayment - show interior horizontal distance of double Type of heat underlayment at eave, etc. Hearing, ventilation, and air conditioning plant locations Overhang detail OiULP-gas tank size, location and piping Provide framing details of frayed/vaulted ceilings Make-up air requirements Provide detail of cathedral ceiling structure and venting Manufactures data for equipment hidicate connection of lower chord of roof trusses and ceiling joists to Heat loss/gain calculations the top plates of interior and exterior walls. Calculate roof tie-down sizes when required by wind conditions • Plumbing plan(s) Show framing for gables in cathedral ceiling construction Plan(s) required _2~,_Provide engineering data for all roof trusses - (truss drawings must be Building trap location signed and sealed by a Connecticut Licensed Professional Engineer) Sewer location Roof rafters over-spanned Domestic water location Ceiling joists over-spanned Manufacturers data for whirlpools, comer tubs, & larger tubs Water heater size, type, and location comments: r'e" RL-0N DCnLfS No Mc w 1 " of-G1I lding 0 icial Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax. 848-7231 Residential Building Permit Application Form Permit # New Construction E] Addition F-1 Alteration Accessory Structure n , F 4j Singfe Family F] Two-Tamily Townhouse Job Address (Number) (street) (Unit) Job Description Owner Mailing Address 146c;O ~+i s I/ City Z4 /z/ State Zip O Tel 4 Contractor Mailing Address City State Zip Tel Contractor's License/Registration Type & Number 1 17 S 3 Exp. Date l / 3 J / Q JJ I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such wor described above. Separate applications are required for electrical, plumbing, , etc. Owner /Agent Signature _ Date Construction Value Fee Building $ $ Plumbing $ $ Mechanical $ $ Electrical $ $ Certificate of Occupancy $ Plan Review Fee $ State Education $ Total $ $ (See &verse side for additional requirements Town of Montville Residential Permit Requirements ❑ Two (2) complete sets of construction documents (to scale) including site plan are required and shall show the following information if applicable. This list is not all-inclusive, additional information may be required for your particular project. • Supporting Documentation • Building Section(s) & Details l Coin feted, si ed and dated Buildin'" Permit A lication p $ pp Floor-to-floor heights Permit fee - calculated upon completion of plan review Material type, size, and spacing Completed building permit affidav for property owners or sole Stair details (rise, run, treads nosing, width> headroom) &Ys or copy of workers compensation insurance Handrail details Copy of Contractor Registration or license Guardrail details Constructi2permit sign-off sheets g ed by all departments Roof ventilation 'c e Code Analysis Heat loss calculations • Framing plans Engineering data for steel beams, engineered lumber, roof trusses or any other engineered products or design Design loads - for floors, ceilings, roofs Street address of project on all drawings and documents Bearing partitions Direction of framing Spans, beam • Site plan Wood species and grade Property lines Framed openings Distance from property to structure Sheathing type and thickness Structure dimensions Window and door header sizes Driveway Decking material, size, spacing Topography (existing and proposed) Note: Unusual structural conditions may require that additional Footing drain inverts, outlet and separation engineering back up be submitted Proposed utilities Wetlands and flood zone limits and elevation • Chimneys and Fireplaces Signed by P & Z, Wetlands, Uncas Health, WPCA Clearances to combustible materials Manufactures data for metal flues • Foundation Plan Exterior fresh air source for fireplaces Assumed soil bearing pressure Flue sizes Dimensions Manufacturers data and installation instructions for metal fireplaces Wall thickness Footing sizes • Electrical Plan(s) Anchor bolts, size and spacing Window and door sizes and locations Panel location(s) with main size Hatchways Meter socket location Columns Outlet locations Floor construction data GFCI outlet locations Drainage details Smoke detector locations Waterproofing details Lights and switches Crawl space ventilation Appliance/equipment circuits Crawl space access Stair illumination Concrete strengths • Mechanical plan(s) • Floor plan(s) Dryer vent Dimensions Bathroom exhaust ventilation (natural or mechanical) type and size Door and window sizes, egress window Hood exhaust Glazing in hazardous locations Type of heat Garageldwelling opening protection Heating, ventilation, and air conditioning plant location Garageldwelling separation Oil tank size, location, and piping Kitchen layout LP-Gas tank location, size, and piping Bathroom layouts, tub sizes in gallons, space clearances Make-air requirements hidicate use of all rooms Manufacturers data for equipment Stair location Attic access location and size • Plumbing plan(s), Square footage for each habitable level of the structure Building trap location if on municipal sewer Required light and ventilation for each habitable room Sewer location Domestic water location • Elevations - minimum of two required Manufacturers data for whirlpools, corner tubs, & larger tubs Type of siding Water heater size, type, and location Roofing Other finishes Finish grades Note: One set of approved plans is Building heights Height of chimney above roof required to be kept on during Roof pitch construction. r+ artmReceipt n o t ~ntvilie Building Dep N t Tow No. 'Date ,OP T F From. Job Address: Check Check # . Cash Amount $Jf (c«i~ ~n~~ Pernt # Received by I NEW RESIDENTIAL PERMIT CALCULATION (2 STORY) Address: House Construction A Average Custom QTY $/UNIT $/UNIT TOTAL Living Area 2200 SF $ 72.08 $ - $ 158,576.00 Finished Basement SF $ 16.01 $ - $ - Unfinished Basement 1100 SF $ 5.72 $ - $ 6,292.00 Kitchen 1 EA $ - $ - $ - Plumbing Full Bath 2 EA $ 4,229.40 $ - $ 4,229.40 Half Bath 1 EA $ 2,691.15 $ - $ Garages Attached, 1 car EA $ 8,885.10 $ - Attached, 2 car 1 EA $ 15,113.70 $ - $ 15,113.70 Attached, 3 car EA $ 20,913.90 $ - $ - Detached, 1 car EA $ 11,657.10 $ - $ Detached, 2 car EA $ 17,456.25 $ - $ Detached, 3 car EA $ 23,256.45 $ $ - Under, 1 car EA $ 1,304.10 $ - $ - Under, 2 car EA $ 1,757.70 $ - $ - Fireplace & Chimney Prefab 1 EA $ 3,963.75 $ - $ 3,963.75 Masonry, exterior EA $ 3,963.75 $ - $ - Masonry, interior EA $ 3,701.25 $ - $ ' W/2 fireplaces EA $ 6,746.25 $ - $ Breezeway/Decks Open 120 SF $ 22.31 $ - $ 2,677.20 Enclosed SF $ 94.76 $ - $ - Porches Open 240 SF $ 62.69 $ - $ 15,045.60 Enclosed SF $ 123.90 $ - $ - Heating Adjustment 2200 SF $ (2.76) $ - $ (6,072.00) Air Conditioning 2200 SF $ 2.84 $ - Electrical 2200 SF $ (5.16) $ - $ (11,352.00) Plumbing 2200 SF $ (5.04) $ - $ (11,088.00) TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 177,385.65 Y Is air conditioning included (Y/N)? $ 6,248.00 PERMIT FEE CALCULATIONS Fee Building $ 177,386 $ 1,424.00 Y Plumbing $ 11,088 $ 96.00 Y Mechanical $ 12,320 $ 104.00 Y Electrical $ 11,352 $ 96.00 Work Commenced before permit issuance $ - CO Fee $ 25.00 Plan Review $ 172.00 State Ed Fee $ 212,146 33.94 Total Fees $ 1,950.94 Based on 2003 RS Means REsidential Cost Data 8/16/04 NEV HOME CONSTRUCTION CONTRACTOR ,PTr DEVELOPMENT 35 BLAIS RD UNCASVILLE, CT 06332 LIC./REG NO. EFFECTIVE EXPIRES i,j5 10/01/2003 09 ^/2005 ~GNED STATE OF CONNECTICUT WORKERS' COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn. Gen. Stat. § 31-286b) Property located at: 4' 0 In the town of Name of building permit applicant: Please check one: 1. K- I am the owner of the above property. 2. I am the sole proprietor of a business. 2A. Name of business: 2B. Federal Employer Identification Number (FEIN) - - - - - - - - - - - Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or principal employer" may provide either a certificate of workers' compensation insurance or a "sworn affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: 1. I do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2. I intend to act as a general contractor or principal employer. Applicant must either provide a certificate of workers' compensation insurance or sign the affidavit below. - Affidavit I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor, subcontractor, or other worker before he/she engages in work on the above property in accordance with the Workers' Compensation Act (Chapter 568). I understand that pursuant to § 31-275 C.G.S., officers of a corporation and partners in a partnership may elect to be excluded from coverage by filing a waiver with the ap riate istrict Office; and that a sole proprietor of a business is not required to have coverage unl i e o accept coverage. Signature of applicant c csworn to before me this Z~ day of 200 (,Not C6xnrniss1mq- er of the Superior Court) ~SAEiWIT NOTARY PUBLIC MY COMMISSION EXPIRES OCT. 31,2W7 Town of Montville Building Department 848-3030, Ext 382 RESIDENTIAL CONSTRUCTION PERMIT SIGN-OFF SHEET Property Address Job Description: 1111 The applicant is responsible for the completion of the form, no permit will be issued until all signatures below have been obtained. HEALTH DISTRICT 848-3030, Ext. 339 6 Approved No Permit - " ❑ Permit ❑ Required Septic Sy tem D to Approved No Permit ❑ Permit ❑ Required Private Well Date WPCA DEPARTMENT 848-3030, Ext 376 Approved No Permit ❑ Permit ❑ Required Municipal Sewer Date Building Trap ❑ Outside ❑ Inside Approved No Permit ❑ Permit # ❑ Required Municipal Water Date DEPARTMENT OF PUBLIC WORKS 848-7473 r Approved No Permit 1P - 7-6 n Permit ; ~ ❑ Required Date PLANNING & ZONING DEPARTMENT 848-3030, Ext. 379 :*ee~ Approved No Permit _ 91Z7/0 Y ❑ Permit ❑ Required Zoning ate Approved No Permit ❑ Permit ❑ Required Inland-Wetlands Date