HomeMy WebLinkAboutSingle Family Residence Town of Montville a Building Department Date/ d 6 / 03 Field Inspection Notice Permit # Job Location ct~ ~Tl~ A Approved Type of Inspection J l ❑ Not Approved - Please call for re-inspection when the following corrections have been completed: i Building Official iTown of Montville F. Building Department Date /l TM Field Inspection No 'ice Permit # .E Job Location Approved Type of Inspection G ❑ Not Approved - Please call for re-inspection when the following corrections have been completed: r. Building Official f; t Town of Montville Building Department Date 62Field Inspection Notice Permit # Job Location AApproved Type of Inspection s f z , 0 ❑ Not Approved - Please call for re-inspection when the following corrections have been completed: Building Official Town of Montville BUILDING DEPARTMENT 310 Norwich-New London Turnpike Uncasville, CT 06382 (860) 848-3030, Ext. 382 Building Permit Permit Number: 52003-0100 Date: 02-Apr-03 Map/Lot: 043/009-007 Owner ID 49533 Job Location: 118 _EQRS)9"QAQ Unit Job Description: Single Family Residence Owner: Contractor: Rtt Development Inc Rtt Development, Inc. 35 Blais Road 35 Blais Rd Uncasville t. 06382- Uncasville CT 06382 Telephone: (860) 889-1662 Lic/Reg Type/No. NHC 1795 Exp Date: 30-Sep-03 Tenant: Self Telephone: Construction Values Permit Fees Construction Information Building Value: $176,113.00 Building Fee: $1,060.00 Use Group: R4 Plumbing Value: $11,088.00 Plumbing Fee: $70.00 Code: 1995 CABO Mechanical Value: $6,072.00 Mechanical Fee: $40.00 Construction Type: 5B Electrical Value: $11,352.00 Electrical Fee: $70.00 Permit Code: R2 Other Value: $0.00 Other Fee: $0.00 Comments: Total Value: $204,625.00 CO Fee: $10.00 Plan Review Fee: $106.00 State Ed Fee: $32.74 Total Fees: $1,388.74 It is the owners responsibility to schedule the follgwing ins ections Cminimurn 48 hours notice required): Fv~ Footing - Prior to pouring concrete W/ Rough HVAC Backfill - Footing drains and waterproofing ❑ Fireplace Throat Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble W Rough Framing Firestopping/draftstopping W Rough Electrical 0 Insulation ❑d Electrical Service ❑ Final Inspection ❑d Rough plumbing and leak test Certificate of Occupany ❑ Gas piping and test 0~ Building Official's Signature: Town of Montville Residential Plan Review Date: A~.l 1 1,"Zoo`3 Job Address: ~of2 SY7 ff xc'- Job Description: We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute 29-263, your application is being reiected for the following reason(s) that are checked-off or commented on: • Supporting Documentation Plans are to be drawn to scale including dimensions of rooms and • Floor plan(s) spaces and all framing information (112.1) Dimensions Building permit application not completed, signed, dated Finish floor elevation Permit fee SIX 9 Minimum room sizes (304.1) Worker's comp. Affidavit or worker' comp. Insurance Door and window sizes Copy Contractor's registration or license Kitchen layout Construction permit sign-off sheet Bathroom layouts, tub sizes in gallons, space clearances Provide all documentation to show compliance with the Model Stair location (min. width 36") (311.1) Energy Code (1995 MEC). Contact your insulation contractor, Attic access location and size Northeast Smart Living Center (1-800-228-7764) or your local Identify the use of each room building official for information. Total square footage for each level of the structure Street address of project on all drawings and documents Indicate required light (8% of floor area per room) and ventilation Heat loss/gain calculations (4% of floor area per room) for each habitable room or space (303. 1.) Indicate safety glazing in areas required such as: doors, windows, tub • Site plan & shower enclosures, etc. (308.4.) floor elevation Indicate bedroom egress windows (5.7 sf net clear opening, 24" clear Finish Signed floby P&Z, r elevation Wetlands, Uncas health WPCA opening height, 20" clear opening width) (310.2.1.) Property lines not provided Egress window maximum sill height 44" (310.2) Distance from property a structure Are basement stairs enclosed/accessible. If so, protect with minimum h sheetrock (310.3.) Structure dimensions Designate which door is the required exit (36" minimum, hinged) Driveway Garage Topography (existing and proposed) Minimum 518" Type X gypsum board separation (on garage side) to Footing drain inverts, outlet and separation all living spaces - all combustible support framing to be covered with Proposed utilities Wetlands and flood zone limits and elevations minimum 5/8" Type X gypsum board if it supports habitable rooms (309.2) Indicate minimum 1 3/a" solid wood door, 1 3/a" solid core steel door, 1 • Foundation Plan 3r" honeycomb core steel door, or 20 minute rated door from the Dimensions garage to the house and its basement or attic (309.1) Wall thickness Indicate self-closing devices on all doors from garage to the house Footing sizes and its basement or attic (309.1) Frost protection required Indicate slope for garage floor (309.3.) -Xv Window and door sizes and locations Hatchway • Elevations Foundation - indicate the assumed soil conditions that the system has Type of siding been designed for or provide engineering data. If presumptive soil Type of roofing conditions cannot be met, provide soil bearing engineering data (401) Other finishes Concrete strength - foundation, floors, exterior porches, walks, slabs Finish grades (402.2) Building heights Basement -finished of unfinished? Dimension height of chimney above roof Vapor barrier between sub-grade and concrete basement floor Roof pitches (505.2.3) Minimum height of foundation walls above finished grade (404.1.3) • Perimeter insulation, if conditioned space Building Section(s) & Details Anchor bolts - size and location (403. La) Floor-to-floor heights Floor thickness and control joint location (403.1.a) Handrails and guardrails - detail, including height and maximum Lally column size, attachment and spacing (408) opening, handrail cross-section, continuity and required returns Column footings - size (403) Show riser height (8 1/a" max), tread depth (9" min.), and nosing (3/4" Waterproofing details (406) -1 1/") Rebar if required - wall length, unbalanced fill, or soil conditions will Show minimum headroom in stairways - 6'-8" measured from nosing determine this. Provide engineering data for complex design. plane to lowest point of ceiling Fireplacetchimney base Stud size and spacing, species and grade (or minimum Fb and E) Concrete piers and anchor details - decks Sheathing - size, thickness, type Foundation drainage - sump, drain to grade, or town storm system; Siding, material, type, style - underlayment per mfg, indicate pitch (405.1) Insulation - R-value, type - including basement walls if applicable Beam pockets - minimum clearances Comer bracing Crawl Spaces Flashing detail - windows and doors - type, material Crawl space data - clearance to joists, slab thickness (if provided), vapor barrier (409) Ventilation (409.1) Access 18"x24" (409.2) - Town of Montville • Framing plans Piers - size, material, depth below grade (minimum 42" required) Bearing partitions Indicate joist hangers at flush framing and ledger Direction of framing Stairs, handrails, and guardrails Beam spans, size, species, grade Framed openings • Chimneys and Fireplaces Sheathing type and thickness Indicate clearance of masonry to combustible framing materials and Window and door header sizes clearance from fireplace opening to finished trim Joists - species and grade (minimum Fb and E), size, direction, and Show data for mechanical flue sizing spacing Show exterior combustion air source Joists over-spanned Flue sizes Headers/beams overspanned Manufactures data and installation instructions for metal fireplaces Double joists at parallel bearing partitions, bathtubs, etc. (502.3.2) Details of framing for plumbing, such as headers and trimmers at • Electrical Plan(s) traps, etc. Joist hangers for flush framing conditions or ledger (502.4.2) Panel location(s) with main size Deck material, type, size, and span Meter socket location Floor insulation - R-value, type, vapor barrier location Outlet locations Provide design data for all unaligned wall and floor bearing points. GFCI outlet locations Indicate location of all point loads. Lights and switches Engineering data for steel beams, engineered lumber, roof trusses or Appliance/equipment circuits any other engineered product or design Stair illumination Roofs/ceilings Stairway light activation at both top and bottom of stair (303.4) Provide roof framing plan for roof geometry Show required ACIDC smoke detectors (316) Ceiling joists - spacing, span, direction, species and grade (or minimum Fb and E) • Mechanical plan(s) Rafters - pitch, spacing, span, species, and grade (or minimum Fb Dryer vent and E) Bathroom exhaust ventilation (natural or mechanical) type and size Insulation - R-value, type -including basement walls if applicable with calculations Ventilation - ridge, gable, soffit Hood exhaust Provide minimum net ventilation data Type of heat Attic access (22"00" minimum) for any attic with 30" or more clear Heating, ventilation, and air conditioning plant locations height OiULP-gas tank size, .location and piping Roof sheathing - type, size, thickness Make-up air requirements Collar ties - size, placement, spacing Manufactures data for equipment Roof covering - shingles - type, nailing, provide proper underlayment - show interior horizontal distance of double • Plumbing plan(s) u reave, etc. Building trap location -Overhang detail Sewer location Provide framing details of trayed/vaulted ceilings Domestic water location Provide detail of cathedral ceiling structure and venting Manufacturers data for whirlpools, corner tubs, & larger tubs Indicate connection of lower chord of roof trusses and ceiling joists to Water heater size, type, and location the top plates of interior and exterior walls. Calculate roof tie-down sizes when required by wind conditions Show framing for gables in cathedral ceiling construction • Following plans are required --Provide engineering data for all roof trusses - (truss drawings must be Site plan signed and sealed by a Connecticut Licensed Professional Engineer) Floor plan(s) Decks/Porches Elevations Plans required Building section & details Joists - size, span, spacing, direction; species and grade (or minimum Electrical plan(s) Fb and E) Mechanical plan(s) Ledger - show attachment and flashing to house Plumbing plan(s) Decking material and size Beam - design data if required Posts - size, material, and height Comments: ilding Official Town of Montville - Building Department..... ~ -Permit #~C> 310 Norwich-New London Tpke. Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax. 848-7231 One & Two Family. Building Permit Application Form ONew Construction Addition ~ Alteration ~ Accessory Structure n other Job Location l✓ S Ar'.0 Job Description/Materials Ownerk-J Mailing Address3 /(",o J / ~f ~i l / ~l~ Z✓ City ~.Q s i/ State c- T Zip V L Tel Contractor Mailing Address. City State Zip Tel Contractor's License/Registration Type & Number > Exp. Date a I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as descri above. Owner /Agent Signature . Dated / d 3 Construction Value Fee Building $ $ Plumbing $ $ Mechanical $ $ Electrical $ Other $ $ Certificate of Occupancy $ Plan Review Fee $ State Education $ Total $ $ (See *verse side for additional requirements) _ Town of Montville Residential Permit RegWmments" + ' ❑ Two (2) complete sets of construction documents (to scale) are required and shall show the following information if applicable. This list is not all-inclusive, additional information may be required for your particular project. • Supporting Documentation • Building Section(s) & Details Qom letrd signed and dated Building Permit Application Floor-to-floor heights Permit fee - calculated upon completion of plan review Material type, size, and spacing Completed building permit affidavit for property owners or sole Stair details (rise, run, treads, nosing, width, headroom) proprietors or copy of workers compensation insurance Handrail details Copy of Contractor Registration or license Guardrail details Construction permit sign-off sheet signed by all departments Roof ventilation Model Energy Code Analysis Heat loss calculations • Framing plans Engineering data for steel beams, engineered lumber, roof trusses or any Design loads - for floors, ceilings, roofs other engineered products or design Street address of project on all drawings and documents Bearing partitions Direction of framing • Site plan Spans, beam Property fines Wood species and grade Framed openings Distance from property to structure l Sheathing type and thickness Structure dimensions Window and door header sizes Driveway Decking material, size, spacing Topography (existing and proposed) Note: Unusual structural conditions may require that additional Footing drain inverts, outlet and separation engineering back up be submitted ` Proposed utilities Wetlands and flood zone limits and elevation • Chimneys and Fireplaces Signed by P & Z, Wetlands, Uncas Health, WPCA Clearances to combustible materials • Foundation Plan Manufactures data for metal flues Exterior fresh air source for fireplaces Assumed soil bearing pressure Flue sizes Dimensions Manufacturers data and installation instructions for metal fireplaces Wall thickness Footing sizes • Electrical Plan(s) Anchor bolts, size and spacing Panel location(s) with main size Window and door sizes and locations Hatchways Meter socket location columns Outlet locations Floor construction data GFCI outlet locations Drainage details Smoke detector locations Waterproofing details Lights and switches Crawl space ventilation Appliance/equipment circuits Crawl space access Stair illumination Concrete strengths • Mechanical plan(s) • Floor plan(s) Dryer vent Dimensions Bathroom exhaust ventilation (natural or mechanical) type and size Door and window sizes, egress window Hood exhaust Glazing in hazardous locations Type of heat Garageldwelling opening protection. Heating, ventilation, and air conditioning plant location Gatageldwelling separation Oil tank size, location, and piping Kitchen layout LP-Gas tank location, size, and piping Bathroom layouts, tub sizes in gallons, space clearances Make-air requirements Indicate use of all rooms Manufacturers data for equipment Stair location Attic access location and size • Plumbing plan(s) Square footage for each habitable level of the structure Building trap location if on municipal sewer Required light and ventilation for each habitable room Sewer location r Domestic water location • Elevations - minimum of two required Manufacturers data for whirlpools, corner tubs, & larger tubs Type of siding Water heater size, type, and location Roofing Other finishes Finish grades Note: One set of approved plans is required to be kept on Building heights site at all times. Height of chimney above roof Roof pitch Town of-Montville Building Depart,-qt Receipt No.~ ~y 3 Date _ ? From: Job Address: cJ12 l Cash Chcc7k Check # Amount $ circle one) # Received by D n r n, ~J Permit Permit Fee Calculation Spreadsheet RESIDENTIAL PERMIT CALCULATION (2 STORY) House Construction A (E=Economy, A=Average, C=Custom) QTY $/UNIT $/UNIT $/UNIT TOTAL Living Area 2200 SF $ - $ 72.08 $ $ 158,576.00 Finished Basement SF $ - $ 16.01 $ - $ - Unfinished Basement 110Q SF $ - $ 5.72 $ - $ 6,292.00 Kitchen EA $ - $ - $ - $ - Plumbing F 4,229.40 $ - $ 4,229.40 Bath Z EA $ $ Full - Half Bath 1 EA $ - $ 2,691.15 $ - $ 2,691.15 Garages Attached, 1 car EA $ - $ 8,885.10 $ - $ - Attached, 2 car 1 EA $ - $ 15,113.70 $ - $ 15,113.70 Attached, 3 car " EA $ - $ 20,913.90 $ - $ - Detached, 1 car EA $ - $ 11,657.10 $ - $ Detached, 2 car - EA $ - $ 17,456.25 $ - $ - Detached, 3 car EA $ - $ 23,256.45 $ - $ - Under, 1 car - EA $ - $ 1,304.10 $ - $ - Under, 2 car - EA $ $ 1,757.70 $ - $ Fireplace & Chimney Prefab EA $ - $ 3,963.75 $ - $ - - Masonry, e)derior _ _EA $ - $ 3,963.75 $ $ Masonry, interior EA $ - $ 3,701.25 $ $ W/2 fireplaces EA $ - $ 6,746.25 $ - $ - Breezeway/Decks Open 120 SF $ - $ 22.31 $ $ 2,677.20 Enclosed SF $ $ 94.76 $ - $ Porches Open 240 SF $ - $ 62.69 $ - $ 15,045.60 Enclosed SF $ - $ 123.90 $ - $ - Heating Adjustment 2200 SF $ - $ (2.76) $ - $ (6,072.00) Air Conditioning 2200 SF $ - $ 284 $ - $ - Electrical 2200 SF $ - $ (5.16) $ - $ (11,352.00) Plumbing 2200 SF $ - $ (5.04) $ - $ (11,088.00) TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 176,113.05 Is air conditioning included (YIN)? $ - PERMIT FEE Building $ 176,113 $ 1,060.00 Y Plumbing $ 11,088 $ 70.00 Y Mechanical $ 6,072 $ 40.00 Y Electrical $ 11,352 $ 70.00 Other $ - CO Fee $ 10.00 Plan Review $ 106.00 State Ed Fee $ 204,625 $ 32.74 Total Fees $ 1,388.74 Based on 2003 RS Means REsidential Cost Data 1/13/03 State of Connecticut Department of Consumer Protection LICENSE VERIFICATION This is to cettify that the Department of Consumer Protection's records indicate the foliowing information regarding: RTT DEVELOPMENT 35 BLAIS RD UNCASVILLE, CT 06382 CrcdLntialNunibcr: NHC.1795 Credential Type: NE HOIE CONSTRUCTION CON TRACTOR License Status: ACTIVE Application Date: 03/02/20M Effective Date: 10/01/2001 Expiration Date: 09/3012003 if you have any further questions, please contact the Department of Consumer Protection Licewe Sec-vices Division at (850) 713-6000. it STATE OF CONNECTICUT WORKERS' COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn. Gen. Stat. § 31-286b) Property located at: In the town of G~ J7` Z Name of building permit applicant: f r v .C y~ ~r,y Please check one: 1. I am the owner of the above property. 2. I am the sole proprietor of a business. 2A. Name of business: 2B. Federal Employer Identification Number (FEIN) Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or principal employer" may provide either a certificate of workers' compensation insurance or a "sworn affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: 1. 1 do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2. I intend to act as a general contractor or principal employer. Applicant must either provide a certificate of workers' compensation insurance or sign the affidavit below. Affidavit I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor, subcontractor, or other worker before he/she engages in work on the above property in accordance with the Workers' Compensation Act (Chapter 568). I understand that pursuant to 31-275 C.G.S., officers of a corpora ' ers in a partnershi lest to be excluded from coverage by filing a waiver with the a r stri ffice; an tl`"s rietor of a business is not required to have coverage unless nt accept age. Signature of applicant Subscribed and sworn to before me this l SA day ofc 200.3. ~otary Public/Commissioner of the superior court) M LINDA L. ROBERTS NOTARY PUBLIC MY COMMISSION EXPIRES OCT. 31, 2007 Town of Montville Building Department 848-3030, Ext 382 ONE & TWO FAMILY CONSTRUCTION PERMIT SIGN-OFF SHEET l or vg TV Aojof) ,w, /I Property Address Job Description: 44riy The owner/agent shall be responsible for the completion of the form, no certificate of occupancy will be issued until all signatures below have been obtained. HEALTH DISTRICT 848-3030-882 _ haled'?, Approved 3 -~7-Q 3 ❑ Permit ❑ Not Applicable Septic Syste Date Approved ❑ Permit El Not Applicable Private Well Date WPCA DEPARTMENT 848-3030, Ext. 881 Approved ❑ Permit ❑ Not Applicable Municipal Sewer Date House Trap ❑ Outside ❑ Inside Approved ❑ Permit # ❑ Not Applicable Municipal Water Date DEPARTMENT OF PUBLIC WORKS 848-7473 Approved ❑ Permit ❑ Not Applicable Director Date PLANNING & ZONING DEPARTMENT 848-3030. Ext. 81 In-Compliance 3 '7 - m El Not Applicable f~ Permit FQ Zoning Date 1 In-Compliance z/` ❑ Permit of Applicable Inland-Wetlands Date F