HomeMy WebLinkAboutSingle Family Residence
Town of Montville
a
Building Department
Date/ d 6 / 03 Field Inspection Notice Permit #
Job Location ct~ ~Tl~
A Approved Type of Inspection J l
❑ Not Approved - Please call for re-inspection when the following corrections have been completed:
i
Building Official
iTown of Montville
F.
Building Department
Date /l TM Field Inspection No 'ice Permit #
.E
Job Location
Approved Type of Inspection
G
❑ Not Approved - Please call for re-inspection when the following corrections have been completed:
r.
Building Official
f;
t
Town of Montville
Building Department
Date 62Field Inspection Notice Permit #
Job Location
AApproved Type of Inspection s f z , 0
❑ Not Approved - Please call for re-inspection when the following corrections have been completed:
Building Official
Town of Montville
BUILDING DEPARTMENT
310 Norwich-New London Turnpike
Uncasville, CT 06382
(860) 848-3030, Ext. 382
Building Permit
Permit Number: 52003-0100 Date: 02-Apr-03 Map/Lot: 043/009-007 Owner ID 49533
Job Location: 118 _EQRS)9"QAQ Unit
Job Description: Single Family Residence
Owner: Contractor:
Rtt Development Inc Rtt Development, Inc.
35 Blais Road
35 Blais Rd Uncasville t. 06382-
Uncasville CT 06382 Telephone: (860) 889-1662
Lic/Reg Type/No. NHC 1795 Exp Date: 30-Sep-03
Tenant:
Self
Telephone:
Construction Values Permit Fees Construction Information
Building Value: $176,113.00 Building Fee: $1,060.00 Use Group: R4
Plumbing Value: $11,088.00 Plumbing Fee: $70.00 Code: 1995 CABO
Mechanical Value: $6,072.00 Mechanical Fee: $40.00 Construction Type: 5B
Electrical Value: $11,352.00 Electrical Fee: $70.00 Permit Code: R2
Other Value: $0.00 Other Fee: $0.00 Comments:
Total Value: $204,625.00 CO Fee: $10.00
Plan Review Fee: $106.00
State Ed Fee: $32.74
Total Fees: $1,388.74
It is the owners responsibility to schedule the follgwing ins ections Cminimurn 48 hours notice required):
Fv~ Footing - Prior to pouring concrete W/ Rough HVAC
Backfill - Footing drains and waterproofing ❑ Fireplace Throat
Concrete Slab - Prior to pouring concrete ❑ Chimney - One flue above thimble
W Rough Framing Firestopping/draftstopping
W Rough Electrical 0 Insulation
❑d Electrical Service ❑ Final Inspection
❑d Rough plumbing and leak test Certificate of Occupany
❑ Gas piping and test
0~
Building Official's Signature:
Town of Montville
Residential Plan Review
Date: A~.l 1 1,"Zoo`3
Job Address: ~of2 SY7 ff xc'-
Job Description:
We have received a building permit application for the above referenced property. In accordance with Connecticut General
Statute 29-263, your application is being reiected for the following reason(s) that are checked-off or commented on:
• Supporting Documentation
Plans are to be drawn to scale including dimensions of rooms and • Floor plan(s)
spaces and all framing information (112.1) Dimensions
Building permit application not completed, signed, dated Finish floor elevation
Permit fee SIX 9 Minimum room sizes (304.1)
Worker's comp. Affidavit or worker' comp. Insurance Door and window sizes
Copy Contractor's registration or license Kitchen layout
Construction permit sign-off sheet Bathroom layouts, tub sizes in gallons, space clearances
Provide all documentation to show compliance with the Model Stair location (min. width 36") (311.1)
Energy Code (1995 MEC). Contact your insulation contractor, Attic access location and size
Northeast Smart Living Center (1-800-228-7764) or your local Identify the use of each room
building official for information. Total square footage for each level of the structure
Street address of project on all drawings and documents Indicate required light (8% of floor area per room) and ventilation
Heat loss/gain calculations (4% of floor area per room) for each habitable room or space (303. 1.)
Indicate safety glazing in areas required such as: doors, windows, tub
• Site plan & shower enclosures, etc. (308.4.)
floor elevation Indicate bedroom egress windows (5.7 sf net clear opening, 24" clear
Finish Signed floby P&Z, r elevation
Wetlands, Uncas health WPCA opening height, 20" clear opening width) (310.2.1.)
Property lines not provided Egress window maximum sill height 44" (310.2)
Distance from property a structure Are basement stairs enclosed/accessible. If so, protect with
minimum h sheetrock (310.3.)
Structure dimensions Designate which door is the required exit (36" minimum, hinged)
Driveway
Garage
Topography (existing and proposed) Minimum 518" Type X gypsum board separation (on garage side) to
Footing drain inverts, outlet and separation all living spaces - all combustible support framing to be covered with
Proposed utilities
Wetlands and flood zone limits and elevations minimum 5/8" Type X gypsum board if it supports habitable rooms
(309.2)
Indicate minimum 1 3/a" solid wood door, 1 3/a" solid core steel door, 1
• Foundation Plan 3r" honeycomb core steel door, or 20 minute rated door from the
Dimensions garage to the house and its basement or attic (309.1)
Wall thickness Indicate self-closing devices on all doors from garage to the house
Footing sizes and its basement or attic (309.1)
Frost protection required Indicate slope for garage floor (309.3.) -Xv
Window and door sizes and locations
Hatchway • Elevations
Foundation - indicate the assumed soil conditions that the system has Type of siding
been designed for or provide engineering data. If presumptive soil Type of roofing
conditions cannot be met, provide soil bearing engineering data (401) Other finishes
Concrete strength - foundation, floors, exterior porches, walks, slabs Finish grades
(402.2) Building heights
Basement -finished of unfinished? Dimension height of chimney above roof
Vapor barrier between sub-grade and concrete basement floor Roof pitches
(505.2.3)
Minimum height of foundation walls above finished grade (404.1.3)
•
Perimeter insulation, if conditioned space Building Section(s) & Details
Anchor bolts - size and location (403. La) Floor-to-floor heights
Floor thickness and control joint location (403.1.a) Handrails and guardrails - detail, including height and maximum
Lally column size, attachment and spacing (408) opening, handrail cross-section, continuity and required returns
Column footings - size (403) Show riser height (8 1/a" max), tread depth (9" min.), and nosing (3/4"
Waterproofing details (406) -1 1/")
Rebar if required - wall length, unbalanced fill, or soil conditions will Show minimum headroom in stairways - 6'-8" measured from nosing
determine this. Provide engineering data for complex design. plane to lowest point of ceiling
Fireplacetchimney base Stud size and spacing, species and grade (or minimum Fb and E)
Concrete piers and anchor details - decks Sheathing - size, thickness, type
Foundation drainage - sump, drain to grade, or town storm system; Siding, material, type, style - underlayment per mfg,
indicate pitch (405.1) Insulation - R-value, type - including basement walls if applicable
Beam pockets - minimum clearances Comer bracing
Crawl Spaces Flashing detail - windows and doors - type, material
Crawl space data - clearance to joists, slab thickness (if provided),
vapor barrier (409)
Ventilation (409.1)
Access 18"x24" (409.2)
- Town of Montville
• Framing plans Piers - size, material, depth below grade (minimum 42" required)
Bearing partitions Indicate joist hangers at flush framing and ledger
Direction of framing Stairs, handrails, and guardrails
Beam spans, size, species, grade
Framed openings • Chimneys and Fireplaces
Sheathing type and thickness Indicate clearance of masonry to combustible framing materials and
Window and door header sizes clearance from fireplace opening to finished trim
Joists - species and grade (minimum Fb and E), size, direction, and Show data for mechanical flue sizing
spacing Show exterior combustion air source
Joists over-spanned Flue sizes
Headers/beams overspanned Manufactures data and installation instructions for metal fireplaces
Double joists at parallel bearing partitions, bathtubs, etc. (502.3.2)
Details of framing for plumbing, such as headers and trimmers at • Electrical Plan(s)
traps, etc.
Joist hangers for flush framing conditions or ledger (502.4.2) Panel location(s) with main size
Deck material, type, size, and span Meter socket location
Floor insulation - R-value, type, vapor barrier location Outlet locations
Provide design data for all unaligned wall and floor bearing points. GFCI outlet locations
Indicate location of all point loads. Lights and switches
Engineering data for steel beams, engineered lumber, roof trusses or Appliance/equipment circuits
any other engineered product or design Stair illumination
Roofs/ceilings Stairway light activation at both top and bottom of stair (303.4)
Provide roof framing plan for roof geometry Show required ACIDC smoke detectors (316)
Ceiling joists - spacing, span, direction, species and grade (or
minimum Fb and E) • Mechanical plan(s)
Rafters - pitch, spacing, span, species, and grade (or minimum Fb Dryer vent
and E) Bathroom exhaust ventilation (natural or mechanical) type and size
Insulation - R-value, type -including basement walls if applicable with calculations
Ventilation - ridge, gable, soffit Hood exhaust
Provide minimum net ventilation data Type of heat
Attic access (22"00" minimum) for any attic with 30" or more clear Heating, ventilation, and air conditioning plant locations
height OiULP-gas tank size, .location and piping
Roof sheathing - type, size, thickness Make-up air requirements
Collar ties - size, placement, spacing Manufactures data for equipment
Roof covering - shingles - type, nailing, provide proper
underlayment - show interior horizontal distance of double • Plumbing plan(s)
u reave, etc. Building trap location
-Overhang detail
Sewer location
Provide framing details of trayed/vaulted ceilings Domestic water location
Provide detail of cathedral ceiling structure and venting Manufacturers data for whirlpools, corner tubs, & larger tubs
Indicate connection of lower chord of roof trusses and ceiling joists to Water heater size, type, and location
the top plates of interior and exterior walls. Calculate roof tie-down
sizes when required by wind conditions
Show framing for gables in cathedral ceiling construction • Following plans are required
--Provide engineering data for all roof trusses - (truss drawings must be Site plan
signed and sealed by a Connecticut Licensed Professional Engineer) Floor plan(s)
Decks/Porches Elevations
Plans required Building section & details
Joists - size, span, spacing, direction; species and grade (or minimum Electrical plan(s)
Fb and E) Mechanical plan(s)
Ledger - show attachment and flashing to house Plumbing plan(s)
Decking material and size
Beam - design data if required
Posts - size, material, and height
Comments:
ilding Official
Town of Montville
- Building Department..... ~ -Permit #~C>
310 Norwich-New London Tpke.
Tel. 848-3030, Ext 382 Uncasville, CT 06382 Fax. 848-7231
One & Two Family. Building Permit Application Form
ONew Construction Addition ~ Alteration ~ Accessory Structure
n other
Job Location l✓ S Ar'.0
Job Description/Materials
Ownerk-J Mailing Address3 /(",o J
/ ~f ~i l / ~l~ Z✓
City ~.Q s i/ State c- T Zip V L Tel
Contractor Mailing Address.
City State Zip Tel
Contractor's License/Registration Type & Number > Exp. Date
a
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted by the
State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee
and that I am authorized to make application for a permit for such work as descri above.
Owner /Agent Signature . Dated / d 3
Construction Value Fee
Building $ $
Plumbing $ $
Mechanical $ $
Electrical $
Other $ $
Certificate of Occupancy $
Plan Review Fee $
State Education $
Total $ $
(See *verse side for additional requirements)
_ Town of Montville
Residential Permit RegWmments" + '
❑ Two (2) complete sets of construction documents (to scale) are required and shall show the following information if
applicable. This list is not all-inclusive, additional information may be required for your particular project.
• Supporting Documentation • Building Section(s) & Details
Qom letrd signed and dated Building Permit Application Floor-to-floor heights
Permit fee - calculated upon completion of plan review Material type, size, and spacing
Completed building permit affidavit for property owners or sole Stair details (rise, run, treads, nosing, width, headroom)
proprietors or copy of workers compensation insurance Handrail details
Copy of Contractor Registration or license Guardrail details
Construction permit sign-off sheet signed by all departments Roof ventilation
Model Energy Code Analysis
Heat loss calculations • Framing plans
Engineering data for steel beams, engineered lumber, roof trusses or any Design loads - for floors, ceilings, roofs
other engineered products or design
Street address of project on all drawings and documents Bearing partitions
Direction of framing
• Site plan Spans, beam
Property fines Wood species and grade
Framed openings
Distance from property to structure l Sheathing type and thickness
Structure dimensions Window and door header sizes
Driveway Decking material, size, spacing
Topography (existing and proposed) Note: Unusual structural conditions may require that additional
Footing drain inverts, outlet and separation engineering back up be submitted `
Proposed utilities
Wetlands and flood zone limits and elevation • Chimneys and Fireplaces
Signed by P & Z, Wetlands, Uncas Health, WPCA Clearances to combustible materials
• Foundation Plan Manufactures data for metal flues
Exterior fresh air source for fireplaces
Assumed soil bearing pressure Flue sizes
Dimensions Manufacturers data and installation instructions for metal fireplaces
Wall thickness
Footing sizes • Electrical Plan(s)
Anchor bolts, size and spacing Panel location(s) with main size
Window and door sizes and locations
Hatchways Meter socket location
columns Outlet locations
Floor construction data GFCI outlet locations
Drainage details Smoke detector locations
Waterproofing details Lights and switches
Crawl space ventilation Appliance/equipment circuits
Crawl space access Stair illumination
Concrete strengths
• Mechanical plan(s)
• Floor plan(s) Dryer vent
Dimensions Bathroom exhaust ventilation (natural or mechanical) type and size
Door and window sizes, egress window Hood exhaust
Glazing in hazardous locations Type of heat
Garageldwelling opening protection. Heating, ventilation, and air conditioning plant location
Gatageldwelling separation Oil tank size, location, and piping
Kitchen layout LP-Gas tank location, size, and piping
Bathroom layouts, tub sizes in gallons, space clearances Make-air requirements
Indicate use of all rooms Manufacturers data for equipment
Stair location
Attic access location and size • Plumbing plan(s)
Square footage for each habitable level of the structure Building trap location if on municipal sewer
Required light and ventilation for each habitable room Sewer location
r Domestic water location
• Elevations - minimum of two required Manufacturers data for whirlpools, corner tubs, & larger tubs
Type of siding Water heater size, type, and location
Roofing
Other finishes
Finish grades Note: One set of approved plans is required to be kept on
Building heights site at all times.
Height of chimney above roof
Roof pitch
Town of-Montville Building Depart,-qt Receipt
No.~ ~y 3
Date _ ?
From:
Job Address: cJ12 l
Cash Chcc7k Check #
Amount $ circle one)
#
Received by D n r n, ~J Permit
Permit Fee Calculation Spreadsheet
RESIDENTIAL PERMIT CALCULATION (2 STORY)
House Construction A (E=Economy, A=Average, C=Custom)
QTY $/UNIT $/UNIT $/UNIT TOTAL
Living Area 2200 SF $ - $ 72.08 $ $ 158,576.00
Finished Basement SF $ - $ 16.01 $ - $ -
Unfinished Basement 110Q SF $ - $ 5.72 $ - $ 6,292.00
Kitchen EA $ - $ - $ - $ -
Plumbing
F 4,229.40 $ - $ 4,229.40
Bath Z EA $ $
Full -
Half Bath 1 EA $ - $ 2,691.15 $ - $ 2,691.15
Garages
Attached, 1 car EA $ - $ 8,885.10 $ - $ -
Attached, 2 car 1 EA $ - $ 15,113.70 $ - $ 15,113.70
Attached, 3 car " EA $ - $ 20,913.90 $ - $ -
Detached, 1 car EA $ - $ 11,657.10 $ - $
Detached, 2 car - EA $ - $ 17,456.25 $ - $ -
Detached, 3 car EA $ - $ 23,256.45 $ - $ -
Under, 1 car - EA $ - $ 1,304.10 $ - $ -
Under, 2 car - EA $ $ 1,757.70 $ - $
Fireplace & Chimney
Prefab EA $ - $ 3,963.75 $ - $ -
-
Masonry, e)derior _
_EA $ - $ 3,963.75 $ $ Masonry, interior EA $ - $ 3,701.25 $ $
W/2 fireplaces EA $ - $ 6,746.25 $ - $ -
Breezeway/Decks
Open 120 SF $ - $ 22.31 $ $ 2,677.20
Enclosed SF $ $ 94.76 $ - $
Porches
Open 240 SF $ - $ 62.69 $ - $ 15,045.60
Enclosed SF $ - $ 123.90 $ - $ -
Heating Adjustment 2200 SF $ - $ (2.76) $ - $ (6,072.00)
Air Conditioning 2200 SF $ - $ 284 $ - $ -
Electrical 2200 SF $ - $ (5.16) $ - $ (11,352.00)
Plumbing 2200 SF $ - $ (5.04) $ - $ (11,088.00)
TOTAL BUILDING CONSTRUCTION COST, LESS MEP $ 176,113.05
Is air conditioning included (YIN)? $ -
PERMIT FEE
Building $ 176,113 $ 1,060.00
Y Plumbing $ 11,088 $ 70.00
Y Mechanical $ 6,072 $ 40.00
Y Electrical $ 11,352 $ 70.00
Other $ -
CO Fee $ 10.00
Plan Review $ 106.00
State Ed Fee $ 204,625 $ 32.74
Total Fees $ 1,388.74
Based on 2003 RS Means REsidential Cost Data
1/13/03
State of Connecticut
Department of Consumer Protection
LICENSE VERIFICATION
This is to cettify that the Department of Consumer Protection's records indicate the foliowing
information regarding:
RTT DEVELOPMENT
35 BLAIS RD
UNCASVILLE, CT 06382
CrcdLntialNunibcr: NHC.1795
Credential Type: NE HOIE CONSTRUCTION CON TRACTOR
License Status: ACTIVE
Application Date: 03/02/20M
Effective Date: 10/01/2001
Expiration Date: 09/3012003
if you have any further questions, please contact the Department of Consumer Protection
Licewe Sec-vices Division at (850) 713-6000.
it
STATE OF CONNECTICUT
WORKERS' COMPENSATION COMMISSION
Building Permit Affidavit for Property Owners or Sole Proprietors
(Conn. Gen. Stat. § 31-286b)
Property located at:
In the town of G~ J7` Z
Name of building permit applicant: f r v .C y~ ~r,y
Please check one:
1. I am the owner of the above property.
2. I am the sole proprietor of a business.
2A. Name of business:
2B. Federal Employer Identification Number (FEIN)
Pursuant to § 31-286b, "a property owner or sole proprietor [who] intends to act as a general contractor or
principal employer" may provide either a certificate of workers' compensation insurance or a "sworn
affidavit... stating that he will require proof of workers' compensation insurance for all those employed on the
job site in accordance with this chapter."
Please check one:
1. 1 do not intend to act as a general contractor or principal employer.
[Sign and stop here]
Signature of applicant
2. I intend to act as a general contractor or principal employer. Applicant must either provide a
certificate of workers' compensation insurance or sign the affidavit below.
Affidavit
I hereby swear and attest that I will require proof of workers' compensation insurance for every contractor,
subcontractor, or other worker before he/she engages in work on the above property in accordance with the
Workers' Compensation Act (Chapter 568).
I understand that pursuant to 31-275 C.G.S., officers of a corpora ' ers in a partnershi lest
to be excluded from coverage by filing a waiver with the a r stri ffice; an tl`"s rietor
of a business is not required to have coverage unless nt accept age.
Signature of applicant
Subscribed and sworn to before me this l SA day ofc 200.3.
~otary Public/Commissioner of the superior court)
M LINDA L. ROBERTS
NOTARY PUBLIC
MY COMMISSION EXPIRES OCT. 31, 2007
Town of Montville
Building Department
848-3030, Ext 382
ONE & TWO FAMILY
CONSTRUCTION PERMIT
SIGN-OFF SHEET
l or vg TV Aojof)
,w, /I Property Address
Job Description: 44riy
The owner/agent shall be responsible for the completion of the form, no certificate of occupancy will be issued until all
signatures below have been obtained.
HEALTH DISTRICT 848-3030-882
_ haled'?, Approved
3 -~7-Q 3 ❑ Permit ❑ Not Applicable
Septic Syste Date
Approved
❑ Permit El Not Applicable
Private Well Date
WPCA DEPARTMENT 848-3030, Ext. 881
Approved
❑ Permit ❑ Not Applicable
Municipal Sewer Date
House Trap ❑ Outside ❑ Inside
Approved
❑ Permit # ❑ Not Applicable
Municipal Water Date
DEPARTMENT OF PUBLIC WORKS 848-7473
Approved
❑ Permit ❑ Not Applicable
Director Date
PLANNING & ZONING DEPARTMENT 848-3030. Ext. 81
In-Compliance
3 '7
- m El Not Applicable
f~ Permit FQ
Zoning Date
1 In-Compliance
z/` ❑ Permit of Applicable
Inland-Wetlands Date
F