HomeMy WebLinkAbout2007 - Certificate of Occupancy/Field Inspection Ticket
t.
TOWN OF MONTVILLE
BUILDING DEPARTMENT
CERTIFICATE OF OCCUPANCY
This is to certify that the work described conforms substantially to the requirements of the State of
Connecticut Building Code and is being issued in accordance with Connecticut General Statute Section 29-
265 and the State of Connecticut Building Code and is hereby approved for use and occupancy.
Property Address: 40 ALLEN DRIVE -Unit:
Job Description: Siingle Familv Dwelling _ _ . _ m_ .
Permit Number: „B2006-0648 x_,_,__._,_,,,,Map/Lot: 090045-00„_„
Use Group: IRC_ Construction Type: IRC,
Code: 2005 State Building
Special Conditions:
I _
i
Owner: Richard A Franklin Design Occupant Load: N/A
Automatic Sprinkler System Required: 0
156 Moxley Road Automatic Sprinkler System Provided: None
Uncasville 063 -
r--
r . _....Wednesdav igptember 26s„2007
Building Official Signature: CO Issued:
Town of Montville
Building Department
310 Norwich-New London Tpke.
Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231
CERTIFICATE OF OCCUPANCY APPROVAL
t? 6) 7~~rjlze
- Property Address
Job Description
No Certificate of Occupancy will be issued until all of the required signatures have been obtained.
Required Department Certificate of Occupancy Approval
Approval
® WPCA au z C?
Required for all occupancies on sewer Sis Orel sate
Comments:
■ Planning & Zoning
Required for all occupancies Signature/ date
Comments:
Health Department
Required for aN occupancies with septic systems Signature/ date
Comments: 9
Department of Public Works
Required when proiect includes driveway work or certain drainage requirements S ig n at i E a e
Comments:
❑ State Dept. of Transportation
Reguired when STC Certificate of Operation is applicable
Signature/ date
Comments:
❑ Police Department
Required for all occupancies - except one & two family Signature/ date
Comments:
❑ Fire Marshal I
Required for all occupancies - except one & two family arf date
Comments:
RtvisedAV= 5, 2005
Town of Montville
Building Department
310 Norwich-New London Tpke.
Uncasville, CT 06382
Tel. 860-848-3030, Ext. 382 Fax. 860-848-7231
WIND LIMITATIONS
AFFIDAVIT
4/1
Address of Property: 44
Job Description:
Building Permit Number:
I hereby swear and attest that I have installed or caused to be installed, all of the required connections
relating to construction in locations where the basic wind speed equals or exceeds 110 miles per hour,
per section R301.2.1.1 of the Connecticut Building Code, as they appear on the construction documents
approved by the Building Department for the above referenced address.
Signature of Contractor:
Name of Contractor: /V
Name of Business - if applicable:
Subscribed and sworn to before me this day of 200.
Signature of Notary Public / Commissioner of the Superior Co
LISA TERRY
W ISSM EWRO 31, 0S
Field Inspection Notice
Town of Montville
Building Department
May 5, 2008
Address. 40 Allen Drive
Job Description: Single Family Residence
Permit Number(s): B2006-0648 - P2007-0028 - N12007-0028 - E2007-0060 Permit Date: 12111/06
Not Approved Approval
INSPECTION Date: Deficiencies Special Date
Conditions
Footings 12/20/06 DJ
• Water proofing on foundation indicates finished •
1/02/07DJ grade. This does not provide adequate frost
Backfill protection along the front and sides of the structure. 1/03/07 DJ
Correct and reschedule an inspection.
Framing 3/14/07 VV • Notched floor joist see plumbing inspection) 3128/07 DJ
3/21107 DJ Notched floor joist has not been repaired.
• Floor joist notched for 3° PVC - depth of notch •
3114107 VV cannot exceed 1/6 of the depth of the member,
Rough Plumbing cannot be more than 1/3 the depth of the member 3/21107 DJ
• No pressure test
e
• Basement ceiling - bundle of wires with more than 3 •
Rough Electrical 3/14/07 VV wires for more than 30" - separate wires or de-rate 3121107 DJ
circuits.
Rough HVAC • Piping Only 3/14/07 VV
Insulation •
° 3128107 DJ
Two deck piers at 4/4/07 DJ
rear deck
4/26107 DJ • The circuit breakers in the main panel must be • Two ground
Electric service labeled. rods present 5121/07 DJ
e
• Access to attic required for inspection.
• Insulate the attic access cover.
• A graspable handrail is required on the stairs to the
Inspection for rear deck.
certificate of • Sheetrock the under side of the stairs leading to the 9/21/07 DJ
occupancy basement due to storage area under the stairs.
• House numbers must be 4" tall and visable form the
street.
•
Rev. Date: 1/18/06 Page 1 of 1