Town of Montville
Building Department
September 27, 2017
Address: 8 Deer Trail
Addition 09/27/17 Permit Closed pursuant to Public Act 17-176—Inspections not completed—no
Job Description: approvals granted
Permit Number(s): B2005-0788 Permit Date: 1/31/06
INSPECTION Not Approved Approval
Date: Deficiencies Special Conditions Date
Pier Footings - 2/13/06 DJ
Footings 5/19/06 DJ . Not ready •• 5/23/06 VV
• Rafter heals at both ends of the 2 x 12 roof rafters • Engineering data
are bearing on the top plate of the walls or on the old received for repairs
roof.The 2 x12"rafters have been reduces to 2 x
Framing 2/29/07 DJ 10's due to these cuts.Repairs are required. 8/29/07 CC
• The LVL hip ridge rafter has also been cut in the
same fashion which voids its engineering design.
Engineering data must be furnished to office.
.
• The required ice and water shield must be present on •
Roofing 5/29/05 DJ the entire roof.This could not be verified in the field
as there was no access to the roof.
Rough Electrical 8/29/07 CC • Penetrations next to swinging door need to be filled •
• Wire to the left of the patio door needs to be
addressed
Insulation 3/13/08 CC • Not Done .
Final Inspection 3/13/08 CC • Front Deck stair railing needs bottom of railing .
for Certificate of sections fastened on both sides
occupancy • Front deck needs the grade brought up around the
landing
• Back deck has unequal riser height on stairs
• Back deck stairs needs the bottom railing section
fastened on the left side.
• Addition at this point is still in the rough in stages
Kitchen Remodel 3/13/08 CC • Outlet to the left of the refrigerator is required to be •
GFCI protected
• GFCI outlet required on the counter space to the
right of the refrigerator
NOTICE: Before a certificate of occupancy can be issued, a C/O sign off sheet must be filled out and
returned to the building department. Sign off sheets are available in the building department.
Note: Fur out original wall to make it flush with the plywood
Include crawlspace when insulating
Dryer vent needs to be continued to the outside—Check length
Framed access required to crawl space—18x24 minimum
Rev.Date: 1/18/06 Page 1 of 1