Loading...
HomeMy WebLinkAbout2009 - New SFR Field Inspection Notice Town of Montville Building Department 37 Cove Rd Continued Address: 37 Cove Road Job Description: New SFR Permit Number(s) B2009-0040 Permit Date: February 25,2009 INSPECTION Not Approved Approval Date: Deficiencies Special Conditions Date Footings-VOID • Structure is relocated .er revised site plan • • VOID-3/9/09 DJ 3/10/09 DJ • Foundation appears to be in a flood plain. • Structure does fall 8/10/09 Structure NOTE: in the flood zone relocated per new requires a review revised site plan for this condition. VV Footings Relocated • 8/10/09 VV 8/20/09 DJ • 6"minimum of stone is required over the top of the • Backfill footing drain pipe. 4/10/12 DJ • Preliminary inspection February of 2010 • Double jack studs are required for all window and door opening over 6' in width. Note the basement window and garage door openings. On the 15'floor note the bay window and two sliders. On the upper most level note the slider. Framing • The stairs from the basement have unequal risers. 4/25/11 DJ • The stairs leading from the first floor to the second 4/10/12 DJ floor including the three steps into the second floor have unequal risers. The landing at the top of the stairs is required to be 36"deep. • Header construction in question.To be verified. The headers are not sized according to Table R502.5 of the 2003 IRC. • None of the typical tie downs anchors are visible. • Foundation to 4/25/11 DJ Plans are to be checked for type and required framing connections locations. No plans on site,call the building 1/13/12 DJ department. 4/25/11 DJ • Piers installed without the required permits and • Decks inspections. 1/13/12 DJ 4/25/11 DJ •• Footings installed without the required permits and • Fireplace inspections. 4/10/12 DJ • Electric service • • 6/29/11 DJ Rough Plumbing • 2/22/12 DJ DWV • • 2/22/12 DJ Rough Electric ' • 2/22/12 DJ Insulation 4/5/12 DJ • 80%Covered prior to 9:30 inspection • • 4/10/12 DJ Rev.Date: 1/18/06 Page 1 of 2 Field Inspection Notice Town of Montville Building Department 37 Cove Rd Continued • No permits on file for Electric, Plumbing and Mechanical • House number not displayed on house or street as required by Town ordinance. • Plans submitted for application do not match structure as built.—Furnish corrected plans • The structure as built has an upper level finished which was not shown on plans and included in permit fees. **Additional fees are due. • Additional Deck was built for the upper level and 6/23/17 DJ none of the decks were charged for. **Permit fees are due for all. • All receptacles in garage must be GFCI protected. • A wall shown on the plans in the basement between an unfinished portion of the basement and a single garage bay has been omitted. 6/23/17 DJ • A wood stove installed in the basement without permit and fees • A set of double glass door exist between the two separate garage areas.Since there is living space with a finished bath room attached to one area these doors must be rated. If the wall omitted from the original plan is installed this would not be required. • A final inspection is required on the main and upper level Final inspection for • Deck ballusters required to be Less than certificate of 4"spacing occupancy • Closet lights not located per code in closet outside master bedroom,kids bedroom closets, closet in accessory apartment • Insulate over attic stair • Widows Peak- 6'8"stair headroom required, handrail required—guard rails required for deck • Smoke/Co detector outside master bedroom not operating properly • Continuous handrail required on main stairway • Door between occupancies cannot lock—lock that is there is keyed deadbolt(not code compliant) • Electrical panels not properly marked • **No permit for water softener and no fees 09/21/17 W collected • Bond copper piping • Remove sored items from attic—the trusses are not designed for storage • Equipment hung from trusses? • Deck permits and payment? • **Portion of garage finished without permits and not code compliant—Fee Due • **Fees cannot be calculated until corrected plans are furnished with dimensions etc. NOTICE: Before a certificate of occupancy can be issued, a C/O signoff sheet must be completed and returned to the building department. Signoff sheets are available in the building department. Rev.Date: 1/18/06 Page 2 of 2