Loading...
HomeMy WebLinkAbout25IWC15 - Site Plan 7-10-2025 REV 8-15-2025SITE RD. F CO L C H E S T E R M A O W N N A ' H S AN SHARP HILL D R I V E C A R O L MA P L E ROAD ROAD DUBO I S FI V E P O I N T S R D . AVE N U E Rockland Pond HIL L LYNCH ROA D OA K D A L E WheelerPond 163 E L T O N CT . D R . GAY H I L L R D . ME A D O W R O A D O L D S P R U C E L A N E X CAROL DRI V E SH A R P H I L L R O A D 1"=1,000' LOCATION MAP 23-LOT RESIDENTIAL RESUBDIVISION 47 SHARP HILL ROAD MONTVILLE, CONNECTICUT 06382 DATE: JULY 10, 2025 REVISED: AUGUST 15, 2025 RESUBDIVISION PLANS SHEET INDEX DWG NO.TITLE SHEET NO. ---EXISTING CONDITIONS 1 ---RECORD SUBDIVISION (1 OF 2)2 ---RECORD SUBDIVISION (2 OF 2)3 DM-1 DEMOLITION PLAN 4 SD-1 SUBDIVISION DEVELOPMENT PLAN 5 GR-1 GRADING PLAN 6 DSW-1 DRAINAGE & STORMWATER MANAGEMENT PLAN 7 UT-1 UTILITY PLAN 8 SE-1 SOIL EROSION & SEDIMENT CONTROL PLAN 9 ---SIGHT LINE DEMONSTRATION PLAN 10 RPP-1 ROADWAY PLAN & PROFILE 11 SEN-1 SOIL EROSION & SEDIMENT CONTROL NARRATIVE AND DETAILS 12 DT-1 SITE DETAILS 13 DT-2 DRAINAGE DETAILS 14 DT-3 UTILITY DETAILS 15 DT-4 STORMWATER MANAGEMENT DETAILS 16 H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PREPARED BY: APPLICANT: MT KINEO BUILDERS, LLC P.O. BOX 246 WEST MYSTIC, CT 06388 PROPERTY OWNER: R&N HOLDING COMPANY, LLC P.O. BOX 246 WEST MYSTIC, CT 06388 CIVIL ENGINEER: H+H ENGINEERING ASSOCIATES, LLC 232 GREENMANVILLE AVENUE, SUITE 201 MYSTIC, CT 06355 LAND SURVEYOR: BOUNDARIES LLC 179 PACHAUG RIVER DRIVE GRISWOLD, CT 06351 PREPARED FOR: MT KINEO BUILDERS, LLC PROPERTY LINE EASEMENT OHEOVERHEAD ELECTRIC SANSANITARY SEWER LINE PR. STORM PIPE WETLAND 50' INLAND WETLAND UPLAND REVIEW AREA TREELINE X XCHAINLINK FENCE VINYL FENCE WOOD FENCE STONEWALL ZONE LINE EX. INDEX CONTOUR EX. INT. CONTOUR 370 368 BUILDING SETBACK LINE ADJOINER PROPERTY LINE LEGEND NEW LOT LINE PR. INDEX CONTOUR PR. INT. CONTOUR 370 368 SFSILT FENCE ETCUNDERGROUND ELECTRIC, TELEPHONE, CABLE TOP OF WALL TW BOTTOM OF WALL BW UTILITY POLE IRON PIPE/IRON ROD IP/IR DRILLHOLE DH TEST PIT TP #2 "TO BE REMOVED"(TBR) "TO REMAIN"(TR) PR. SPOT GRADE 395.6 OR 395x6 STMEX. STORM PIPE CONCRETE MONUMENT MON    ABUTTERS1.Bruce R. Duchesneau, 45 Sharp Hill Road2.Kimberly A. Bennett, 55 Sharp Hill Road3.Mary Ellen Martin, 7 Carol Drive4.Matthew B. Smith, 11 Carol Drive5.James M. & Joanne Westall, 15 Carol Drive6.Elizabeth E. Knoche, 21 Carol Drive7.Heidi Schlunz, 25 Carol Drive8.David & Lori Redston, 29 Carol Drive  Zone R-40 Zone R-20 Zone I Zone R-20 Zone I Zone R-20 Z o n e R - 2 0 Z o n e R - 1 2 0 N/FNathan McKelvey &Katherine E. McKelvey39 Sharp Hill Road N/FNancy J. Radgowski27 Sharp Hill Road 1 2 N/FBetty Ann Dessert59 Sharp Hill Road 34 56 789 1011 12131415 16 N/FKudziaFamily Trust550 Route 163 N/FGHP LLC430 Maple Avenue N/FKevin G. McCarthy &Darlene A. McCarthy392 Maple Avenue N/FBrent A. &Dianne L. Devine,Trustees32 Sharp Hill Road N/FAlex J. Graf42 Sharp Hill Road N/FJean Pierre &Janet Lesieur48 Sharp Hill Road N/FLucille R. Green64 Sharp Hill Road 17 18 19 20 21 22 23 N/FAdvanced Associates LLC410 Maple Avenue Sha r p Hill Roa d Carol Δ Δ Δ Drive Subject Property Area: 848,099± SF 19.47± Acres Revisions SHEET NO. 1 Im p r o v e m e n t L o c a t i o n & T o p o g r a p h i c S u r v e y "E x i s t i n g C o n d i t i o n s " Pr e p a r e d F o r Mt K i n e o B u i l d e r s , L L C 47 S h a r p H i l l R o a d - M o n t v i l l e , C o n n e c t i c u t July 2025 JOB I.D. NO. P: \ C I V I L 3 D P R O J E C T S \ 2 0 2 4 \ 2 4 - 3 5 1 4 M T K I N E O S H A R P H I L L \ D W G \ D E S I G N \ 1 E X I S T I N G C O N D I T I O N S R E V A . D W G 24-3514 DATE: SCALE: 16 GRAPHIC SCALE 1" = 80' BL LEGEND & ABBREVIATIONS ©2025 BOUNDARIES LLC THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLC AND HAS BEEN SPECIFICALLYPREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BEDUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT,LOCATION OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENT OFBOUNDARIES LLC. NOT VALID WITHOUT LIVE SIGNATURE AND EMBOSSED SEAL.  REFERENCE MAPS SURVEY NOTES ABUTTERS 1.Bruce R. Duchesneau & Lisa A. Duchesneau, 45 Sharp Hill Road2.Kimberly A. Bennett, 55 Sharp Hill Road3.Mary Ellen Martin, 7 Carol Drive4.Matthew B. Smith, 11 Carol Drive5.James M. Westall & Joanne Westall, 15 Carol Drive6.Elizabeth E. Knoche, 21 Carol Drive7.Heidi Schlunz, 25 Carol Drive8.David Redston & Lori Redston, 29 Carol Drive9.James P. Cascio, 33 Carol Drive10.Tomas Felipe Buitrago, 37 Carol Drive11.Cody E. Demichele & Jessica A. McWilliam, 41 Carol Drive12.Kristopher Sprague, 45 Carol Drive13.Matthew R. Dimarco & Nicole Thibeault, 49 Carol Drive14.AJ Scott Whitten & Kimberly Mae Whitten, 53 Carol Drive15.Simon Xie & Sanni Sit, 57 Carol Drive16.Daniel Conroy, 56 Carol Drive17.Stephen W. & Sherri W. Payette, 36 Carol Drive18.Brent M. Autin, 32 Carol Drive19.William L. III & Stephanie A. Deason, 28 Carol Drive20.Sidra Habib Khatri & Kevin Yi Zhang, 24 Carol Drive21.Freddisha B. Williams, 20 Carol Drive22.Evelyn Pietrella, 16 Carol Drive23.Laura J. Anton, 12 Carol Drive Rev. "A" 8-15-2025 Per Town Comments       ABUTTERS    Zone R-40 Zone R-20 Zone I Zone R-20 23 22 21 20 19 18 16 11 17 9 7 6 1 13 2 14 34 5 8 10 12 15Open Space Sha r p Hill Roa d Carol Drive Curve Table Line Table Revisions SHEET NO. 2 Im p r o v e m e n t L o c a t i o n & T o p o g r a p h i c S u r v e y "R e c o r d R e s u b d i v i s i o n " Pr e p a r e d F o r Mt K i n e o B u i l d e r s , L L C 47 S h a r p H i l l R o a d - M o n t v i l l e , C o n n e c t i c u t July 2025 JOB I.D. NO. P: \ C I V I L 3 D P R O J E C T S \ 2 0 2 4 \ 2 4 - 3 5 1 4 M T K I N E O S H A R P H I L L \ D W G \ D E S I G N \ 2 3 S U B D I V I S I O N R E V A . D W G 24-3514 DATE: SCALE: 16 GRAPHIC SCALE 1" = 50' ©2025 BOUNDARIES LLC THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLC AND HAS BEEN SPECIFICALLYPREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BEDUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT,LOCATION OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENT OFBOUNDARIES LLC. NOT VALID WITHOUT LIVE SIGNATURE AND EMBOSSED SEAL. Ma t c h L i n e ( S e e S h e e t 3 ) Rev. "A" 8-15-2025 Per Town Comments  Zone I Zone R-20 Z o n e R - 2 0 Z o n e R - 1 2 0 Open Space Carol Drive Δ Revisions SHEET NO. 3 Im p r o v e m e n t L o c a t i o n & T o p o g r a p h i c S u r v e y "R e c o r d R e s u b d i v i s i o n " Pr e p a r e d F o r Mt K i n e o B u i l d e r s , L L C 47 S h a r p H i l l R o a d - M o n t v i l l e , C o n n e c t i c u t July 2025 JOB I.D. NO. P: \ C I V I L 3 D P R O J E C T S \ 2 0 2 4 \ 2 4 - 3 5 1 4 M T K I N E O S H A R P H I L L \ D W G \ D E S I G N \ 2 3 S U B D I V I S I O N R E V A . D W G 24-3514 DATE: SCALE: 16 GRAPHIC SCALE 1" = 50' ©2025 BOUNDARIES LLC THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLC AND HAS BEEN SPECIFICALLYPREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BEDUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT,LOCATION OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENT OFBOUNDARIES LLC. NOT VALID WITHOUT LIVE SIGNATURE AND EMBOSSED SEAL. Ma t c h L i n e ( S e e S h e e t 2 ) Rev. "A" 8-15-2025 Per Town Comments OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OHE OH E OH E OH E OH E OH E OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X SA N SAN SA N SA N SAN SA N SA N SAN SA N SAN SA N SAN SA N SAN SAN SA N SAN SA N SA N SAN STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S TP#9 TP#8 TP#1 TP#2 TP#3 TP#4 TP#5 TP#6 TP#7 CL&P 3895 TP#11 TP#10 ZONE R-2 0 ZONE R- 4 0 ZONE 1 418 416 414 412 410 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 4 1 4 41 2 4 1 0 4 0 8 406 404 402 400 398 396 394 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 352 350 348 344 342 340 338 336 334 332 330 328 326 404 402 400 398 396 394 392 390 388 386 384 382 380 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 85C 'C' 47C 'C/D' 62D'B' 30" TREE 32" TREE 32" TREE 46" TRIPLE TREE 14" TREE EXISTING SMH TF=401.34 INV 10" PVC=394.44 INV 10" PVC=389.86 CT6011 CL&P 6010 IP S EXISTING SMH TF=369.66 FL=359.16 CL&P 6009 W/UG UPOLE CP6008 6007 6007 EXISTING BITUMINOUS DRIVEWAY EXISTING SMH TF=337.17 FL=328.05 HELT 9258 9190 CL&P 9787 EVS 9788 EXI S T I N G RES I D E N C E EX I S T I N G RE S I D E N C E EX I S T I N G DE C K CAROL DRI V E SH A R P H I L L R O A D DH N/F LUCILLE R. GREEN 64 SHARP HILL ROAD N/F JEAN PIERRE & JANET LESIEUR 48 SHARP HILL ROAD N/F ALEX J. GRAF 42 SHARP HILL ROAD N/F BRENT A & DIANNE L. DEVINE, TRUSTEES 32 SHARP HILL ROAD N/F NATHAN MCKELVEY & KATHERINE E. MCKELVEY 39 SHARP HILL ROADN/F KEVIN G. & DARLENE A. MCCARTHY 392 MAPLE AVENUE N/F ADVANCED ASSOCIATES LLC 410 MAPLE AVENUE EXISTING CB TYPE "C" TF=398.40 EXISTING CB TYPE "C" TF=398.47 INV (S) 15" RCP=393.97 INV (SW) 15" RCP=393.97 INV (NE) 15" RCP=393.82 EXISTING CB TYPE "C" TF=366.15 INV (S) 6" PVC=363.05 INV (N) 15" RCP=365.15 EXISTING CB TYPE "C" TF=365.97 INV (S) 15" RCP=360.97 INV (SW) 15" RCP=360.97 INV (NE) 15" RCP=393.87 EXISTING CB TYPE "C" TF=337.65 EXISTING CB TYPE "CL" TF=435.17 EXISTING CB TYPE "C" TF=337.01 ZONE R- 2 0 EXISTING 1 STORY RESIDENCE S5 5 ° 0 9 ' 5 7 " W 15 0 . 1 6 ' N5 5 ° 0 9 ' 5 7 " E 14 9 . 4 7 ' N33°15'22"W 100.20' 84B 'C' 84B 'C' EXISTING SHED EXISTING BIT. DRIVEWAY WF#2-2 WF#2-1 WF#2-4 WF#2-3 DH DH DH DH EXISTING DILAPIDATED SHED EXISTING SHED 47C 'C/D' 47C 'C/D' 85C 'C' 46B 'C/D' 47C 'C/D' MON MON MON MONMON MON MON MONMON MON MONMON N/F BRUCE & LISA DUCHESNEAU 45 SHARP HILL ROAD TP#101 TP#102 TP#103 TP#104 TP#105 SAWCUT LINE (TYP.) REMOVE VEGETATION, DEBRIS,OR UNSUITABLE MATERIAL WITHIN LIMITS OF PROPOSED CONSTRUCTION (TBR) (TR) (TR) (TR) (TR) CONCEPTUAL NEW TREELINE (BASED ON FULL SUBDIVISION DEVELOPMENT) 50025 SCALE IN FEET 50 EN SW GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY. 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : DE M O L I T I O N P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 DM-1 4 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 4 _ D E M O . D W G T a b : 4 D E M O S a v e d : 8/ 1 5 / 2 0 2 5 1 2 : 3 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 8 P M OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OHE OH E OH E OH E OH E OH E OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X SA N SAN SA N SA N SAN SA N SA N SAN SA N SAN SA N SAN SA N SAN SAN SA N SAN SA N SA N SAN STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S TP#9 TP#8 TP#1 TP#2 TP#3 TP#4 TP#5 TP#6 TP#7 CL&P 3895 TP#11 TP#10 ZONE R-2 0 ZONE R- 4 0 ZONE 1 418 416 414 412 410 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 4 1 4 41 2 4 1 0 4 0 8 406 404 402 400 398 396 394 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 352 350 348 344 342 340 338 336 334 332 330 328 326 404 402 400 398 396 394 392 390 388 386 384 382 380 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 30" TREE 32" TREE 32" TREE 46" TRIPLE TREE 14" TREE CT6011 CL&P 6010 IP S CL&P 6009 W/UG UPOLE CP6008 6007 6007 EXISTING BITUMINOUS DRIVEWAY HELT 9258 9190 CL&P 9787 EVS 9788 EXI S T I N G RES I D E N C E EX I S T I N G RE S I D E N C E EX I S T I N G DE C K CAROL DRI V E SH A R P H I L L R O A D DH N/F LUCILLE R. GREEN 64 SHARP HILL ROAD N/F JEAN PIERRE & JANET LESIEUR 48 SHARP HILL ROAD N/F ALEX J. GRAF 42 SHARP HILL ROAD N/F BRENT A & DIANNE L. DEVINE, TRUSTEES 32 SHARP HILL ROAD N/F NATHAN MCKELVEY & KATHERINE E. MCKELVEY 39 SHARP HILL ROADN/F KEVIN G. & DARLENE A. MCCARTHY 392 MAPLE AVENUE N/F ADVANCED ASSOCIATES LLC 410 MAPLE AVENUE ZONE R- 2 0 EXISTING 1 STORY RESIDENCE EXISTING SHED EXISTING BIT. DRIVEWAY WF#2-2 WF#2-1 WF#2-4 WF#2-3 DH DH DH DH EXISTING SHED MON MON MON MONMON MON MON MONMON MON MONMON N/F BRUCE & LISA DUCHESNEAU 45 SHARP HILL ROAD TP#101 TP#102 TP#103 TP#104 TP#105 NEW BITUMINOUS CONCRETE PAVEMENT (TYP.) NEW STORMWATER MANAGEMENT BASINS (SEE GRADING PLAN, AND DRAINAGE & STORMWATER MANAGEMENT PLAN) 1 0 ' S Y S E T B A C K ( T Y P . ) W CONCEPTUAL LOCATION OF NEW DRILLED WELL (TYP.) CROSS HATCHED AREA DENOTES SIGHT LINE EASEMENT OVER LAND OF N/F BRUCE & LISA DUCHESNEAU GRAY SHADED AREA DENOTES TEMPORARY CONSTRUCTION & GRADING EASEMENT OVER LAND OF N/F BRUCE & LISA DUCHESNEAU 1 0 ' S Y S E T B A C K ( T Y P . ) 30' FY SE T B A C K ( T Y P . ) 30' RY SE T B A C K ( T Y P . ) 1ST FL F F E = 3 8 2 . 0 BSMT=37 2 . 0 1ST F L F F E = 3 6 7 . 8 GARA G E = 3 6 4 . 8 1ST F L F F E = 3 6 9 . 7 GAR A G E = 3 6 6 . 7 1ST FL FFE=368.6 GARAGE=365.6 1ST FL F F E = 3 8 0 . 0 GARAGE= 3 7 8 . 0 1ST FL F F E = 3 7 3 . 4 GARAGE= 3 7 0 . 4 1ST FL F F E = 3 8 7 . 9 GARAGE= 3 8 3 . 9 1S T F L F F E = 4 0 1 . 0 GA R A G E = 3 9 8 . 5 1ST FL F F E = 3 9 3 . 6 GARAGE= 3 9 1 . 6 1ST FL FFE=399.4 GARAGE=396.91ST FL FFE=400.0 GARAGE=398.0 1ST FL FFE=401.0 GARAGE=398.5 1ST FL FFE=407.3 GARAGE=404.3 1ST F L F F E = 3 9 9 . 0 GAR A G E = 3 9 7 . 0 1 S T F L F F E = 4 0 0 . 0 G A R A G E = 3 9 8 . 0 1ST F L F F E = 3 9 4 . 0 GAR A G E = 3 9 2 . 0 1ST FL FFE=395 . 5 GARAGE=393.5 BSMT=385.5 1ST F L F F E = 3 9 6 . 0 GARA G E = 3 9 4 . 0 BSMT = 3 8 6 . 0 1ST FL F F E = 3 9 0 . 0 GARAGE = 3 8 8 . 0 BSMT=38 0 . 0 1ST FL F F E = 3 8 4 . 0 GARAGE = 3 8 2 . 0 BSMT=37 4 . 0 1ST FL F F E = 3 7 8 . 0 GARAGE= 3 7 6 . 0 BSMT=36 8 . 0 1ST FL F F E = 3 7 2 . 0 GARAGE= 3 7 0 . 0 BSMT=36 2 . 0 1ST FL FFE = 3 6 7 . 0 GARAGE=3 6 5 . 0 BSMT=357. 0 1ST FL FFE=396.0 GARAGE=394.0 BSMT=386.0 LOT 1 LOT 2 LOT 3 LOT 4 LOT 6 LOT 7 LOT 5 LOT 8LOT 10 LOT 11 LOT 9 LOT 12 LOT 14 OPEN SPACE LOT 16 LOT 17 W W W W W W W W W LOT 13 W W W W W W W W W W W W W LOT 15 LOT 19 LOT 20 LOT 18 LOT 21 LOT 22 LOT 23 NEW 12" PAINTED STOP BAR AND 30" 'STOP' SIGN NEW BITUMINOUS CONCRETE LIP CURB (TYP.) NEW 2'x2' YARD DRAIN (TYP.) 2 4 . 0 ' NEW COMMUNITY MAIL BUILDING 15.0' 12.0' NEW COMMON DRIVE NEW PRIVATE DRIVE (TYP.) NEW 136 L.F. TIMBER GUIDERAIL NEW STORMWATER INFILTRATION TRENCH (SEE GRADING PLAN, AND DRAINAGE & STORMWATER MANAGEMENT PLAN) 50025 SCALE IN FEET 50 EN SW SITE NOTES: 1.ALL TRAFFIC CONTROL SIGNS AND PAVEMENT MARKINGS SHALL BE INSTALLED IN THE LOCATIONS SHOWN AND IN ACCORDANCE WITH THE MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES (M.U.T.C.D.). ALL PARKING LOT STRIPING (EXCEPT FIRE LANE MARKINGS) SHALL BE INSTALLED WITH DURABLE WHITE PAVEMENT MARKING PAINT. THE HANDICAP PARKING SYMBOLS SHALL BE WHITE WITH STANDARD HANDICAP BLUE BACKGROUNDS. 2.ALL DISTURBED AREAS NOT COVERED BY BUILDINGS, ASPHALT, STONE SURFACE OR WALKS SHALL BE LANDSCAPED OR GRASSED. GRASSED AREAS SHALL BE LOAMED (4" MIN.) FERTILIZED, SEEDED AND MULCHED AS REQUIRED TO SUIT SOIL CONDITIONS. 3.ANY AND ALL SIGNAGE SHALL BE REVIEWED AND APPROVED BY THE TOWN ZONING ENFORCEMENT OFFICER AND/OR PLANNING & ZONING COMMISSION PRIOR TO INSTALLATION. 4.A LICENSED LAND SURVEYOR SHALL SET A SITE BENCHMARK AND STAKE OUT THE PROPOSED ROADWAY PRIOR TO CONSTRUCTION. DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : SU B D I V I S I O N D E V E L O P M E N T P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 SD-1 5 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 5 _ S I T E D E V E L O P M E N T P L A N . D W G T a b : 5 S I T E D E V E L O P M E N T P L A N S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 4 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 8 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY. W 1ST FL F F E = 3 8 2 . 0 BSMT=37 2 . 0 1ST F L F F E = 3 6 7 . 8 GAR A G E = 3 6 4 . 8 1ST F L F F E = 3 6 9 . 7 GAR A G E = 3 6 6 . 7 1ST FL FFE=368.6 GARAGE=365.6 1ST FL F F E = 3 8 0 . 0 GARAGE= 3 7 8 . 0 1ST FL F F E = 3 7 3 . 4 GARAGE= 3 7 0 . 4 1ST FL F F E = 3 8 7 . 9 GARAGE= 3 8 3 . 9 1S T F L F F E = 4 0 1 . 0 GA R A G E = 3 9 8 . 5 1ST FL F F E = 3 9 3 . 6 GARAGE= 3 9 1 . 6 1ST FL FFE=399.4 GARAGE=396.91ST FL FFE=400.0 GARAGE=398.0 1ST FL FFE=401.0 GARAGE=398.5 1ST FL FFE=407.3 GARAGE=404.3 1ST F L F F E = 3 9 9 . 0 GAR A G E = 3 9 7 . 0 1 S T F L F F E = 4 0 0 . 0 G A R A G E = 3 9 8 . 0 1ST F L F F E = 3 9 4 . 0 GAR A G E = 3 9 2 . 0 1ST FL FFE=395 . 5 GARAGE=393.5 BSMT=385.5 1ST F L F F E = 3 9 6 . 0 GARA G E = 3 9 4 . 0 BSMT = 3 8 6 . 0 1ST FL F F E = 3 9 0 . 0 GARAGE = 3 8 8 . 0 BSMT=38 0 . 0 1ST FL F F E = 3 8 4 . 0 GARAGE = 3 8 2 . 0 BSMT=37 4 . 0 1ST FL F F E = 3 7 8 . 0 GARAGE= 3 7 6 . 0 BSMT=36 8 . 0 1ST FL F F E = 3 7 2 . 0 GARAGE= 3 7 0 . 0 BSMT=36 2 . 0 1ST FL FFE = 3 6 7 . 0 GARAGE=3 6 5 . 0 BSMT=357. 0 1ST FL FFE=396.0 GARAGE=394.0 BSMT=386.0 W W W W W W W W W W W W W W W W W W W W W W OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OHE OH E OH E OH E OH E OH E OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S 1146 10 TWIN TP#9 TP#8 TP#1 TP#2 TP#3 TP#4 TP#5 TP#6 TP#7 CL&P 3895 TP#11 TP#10 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 418 416 414 412 410 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 4 1 4 41 2 4 1 0 4 0 8 406 404 402 400 398 396 394 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 352 350 348 344 342 340 338 336 334 332 330 328 326 404 402 400 398 396 394 392 390 388 386 384 382 380 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 85C 'C' 47C 'C/D' 62D'B' 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 30" TREE 32" TREE 32" TREE 46" TRIPLE TREE 14" TREE CT6011 CL&P 6010 IP S CL&P 6009 W/UG UPOLE CP6008 6007 6007 EXISTING BITUMINOUS DRIVEWAY HELT 9258 9190 CL&P 9787 EVS 9788 EXI S T I N G RES I D E N C E EX I S T I N G RE S I D E N C E EX I S T I N G DE C K CAROL DRI V E SH A R P H I L L R O A D DH EXISTING CB TYPE "C" TF=398.40 EXISTING CB TYPE "C" TF=398.47 INV (S) 15" RCP=393.97 INV (SW) 15" RCP=393.97 INV (NE) 15" RCP=393.82 EXISTING CB TYPE "C" TF=366.15 INV (S) 6" PVC=363.05 INV (N) 15" RCP=365.15 EXISTING CB TYPE "C" TF=365.97 INV (S) 15" RCP=360.97 INV (SW) 15" RCP=360.97 INV (NE) 15" RCP=393.87 EXISTING CB TYPE "C" TF=337.65 EXISTING CB TYPE "CL" TF=435.17 1146 10 TWIN EXISTING 1 STORY RESIDENCE 84B 'C' 84B 'C' EXISTING SHED EXISTING BIT. DRIVEWAY WF#2-2 WF#2-1 WF#2-4 WF#2-3 DH DH DH DH EXISTING DILAPIDATED SHED EXISTING SHED 47C 'C/D' 47C 'C/D' 85C 'C' 46B 'C/D' 47C 'C/D' MON MON MON MONMON MON MON MONMON MON MONMON TP#101 TP#102 TP#103 TP#104 TP#105 CB-1 CB-2 CB-3 CB-4 CB-5 (CHANGE TO "CL" TOP) YD-1 YD-2 YD-3 YD-4 YD-5 YD-6 YD-7 YD-8 3 6 5 3 7 0 3 8 0 3 9 0 380 375 385 385 380 405 405 380 385 375 370 365 380 3 8 0 370 375 375 370 370 365 380 360370 365 360 3 7 0 3 6 5 3 6 0 355 38 0 375 366 367 368 364 363 361 3 6 3 3 6 4 3 6 6 3 6 7 3 6 8 3 6 9 3 7 1 3 7 2 3 7 3 3 7 4 3 7 8 3 8 2 383 3 8 4 3 8 6 397 38 3 397 379 381 382 384 369 364 364 363 366 354 BIORETENTION BASIN 'C' TOP OF BERM=392.00 TOP OF SPILLWAY=391.50 BOTTOM OF BASIN=388.00 3 6 1 365 343.5 345 350 355357357 355 SEDIMENT FOREBAY/ WATER QUALITY BASIN TOP OF BERM=357.00 TOP OF SPILLWAY=356.5 BOTTOM O F BASIN=354.00 BIORETENTION BASIN 'B' TOP OF BERM=344.00 TOP OF SPILLWAY=343.00 BOTTOM OF BASIN=338.00 BIORETENTION BASIN 'A' TOP OF BERM=347.50 TOP OF SPILLWAY=347.00 BOTTOM O F BASIN=343.50 335 340 344344 340338 338 340 345347 347 345 332 334 3 4 5 3 4 8 3 4 4 3 4 4 3 4 5 3 4 7 3 4 7 3 4 5 338340 344344 3 6 2 3 7 5 3 7 6 3 7 7 3 7 9 3 8 1 3 8 2 3 8 3 3 8 5 3 8 7 3 8 8 3 8 9 3 9 0 3 9 1 3 9 2 3 9 3 3 9 4 3 9 5 395 388 389 390 391 392 393 394 395 397 39 8 405 410 415 4 0 4 403 40 1 39 9 410 415 410 405 120 415 410 405 4 0 5 4 1 0 415 390 390 390 385 394 393 393 391 3 9 5 391 390 383 377 3 9 3 3 8 7 3 8 1 3 6 9 3 7 5 394 3 9 4 400 4 0 0 395 395 390 388 392 392 384 382384 3 9 6 3 9 7 NEW STORMWATER MANAGEMENT AREA 'A' - 24"(W) INFILTRATION TRENCH. TOP OF STONE VARIES WITH GRADE (MAX.=365.5; MIN.=361.0) BOTTOM OF STONE=360.0 EN SW 50025 SCALE IN FEET 50 DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : GR A D I N G P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 GR-1 6 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 6 - 0 7 _ G R A D I N G P L A N . D W G T a b : 6 G R A D I N G P L A N S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 4 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 8 P M GRADING NOTES: 1.THE PROPOSED SITE GRADING SHALL CONFORM TO THE GRADING SHOWN ON THIS PLAN WITH MINOR ADJUSTMENTS AS NECESSARY DUE TO ACTUAL FIELD CONDITIONS. 2.THE SITE CONTRACTOR SHALL REVIEW THE SITE GRADES AND FEATURES TO ENSURE THAT THE PROPOSED WORK IS CONSISTENT WITH THE EXISTING CONDITIONS AS PRESENTED ON THE PLANS. 3.A LICENSED LAND SURVEYOR SHALL SET A SITE BENCHMARK PRIOR TO CONSTRUCTION. GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY. 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T W 1ST FL F F E = 3 8 2 . 0 BSMT=37 2 . 0 1ST F L F F E = 3 6 7 . 8 GAR A G E = 3 6 4 . 8 1ST F L F F E = 3 6 9 . 7 GAR A G E = 3 6 6 . 7 1ST FL FFE=368.6 GARAGE=365.6 1ST FL F F E = 3 8 0 . 0 GARAGE= 3 7 8 . 0 1ST FL F F E = 3 7 3 . 4 GARAGE= 3 7 0 . 4 1ST FL F F E = 3 8 7 . 9 GARAGE= 3 8 3 . 9 1S T F L F F E = 4 0 1 . 0 GA R A G E = 3 9 8 . 5 1ST FL F F E = 3 9 3 . 6 GARAGE= 3 9 1 . 6 1ST FL FFE=399.4 GARAGE=396.91ST FL FFE=400.0 GARAGE=398.0 1ST FL FFE=401.0 GARAGE=398.5 1ST FL FFE=407.3 GARAGE=404.3 1ST F L F F E = 3 9 9 . 0 GAR A G E = 3 9 7 . 0 1 S T F L F F E = 4 0 0 . 0 G A R A G E = 3 9 8 . 0 1ST F L F F E = 3 9 4 . 0 GAR A G E = 3 9 2 . 0 1ST FL FFE=395 . 5 GARAGE=393.5 BSMT=385.5 1ST FL F F E = 3 9 6 . 0 GARA G E = 3 9 4 . 0 BSMT = 3 8 6 . 0 1ST FL F F E = 3 9 0 . 0 GARAGE = 3 8 8 . 0 BSMT=38 0 . 0 1ST FL F F E = 3 8 4 . 0 GARAGE = 3 8 2 . 0 BSMT=37 4 . 0 1ST FL F F E = 3 7 8 . 0 GARAGE= 3 7 6 . 0 BSMT=36 8 . 0 1ST FL F F E = 3 7 2 . 0 GARAGE= 3 7 0 . 0 BSMT=36 2 . 0 1ST FL FFE = 3 6 7 . 0 GARAGE=3 6 5 . 0 BSMT=357. 0 1ST FL FFE=396.0 GARAGE=394.0 BSMT=386.0 W W W W W W W W W W W W W W W W W W W W W W OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OHE OH E OH E OH E OH E OH E OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S 1146 10 TWIN TP#9 TP#8 TP#1 TP#2 TP#3 TP#4 TP#5 TP#6 TP#7 CL&P 3895 TP#11 TP#10 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 418 416 414 412 410 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 4 1 4 41 2 4 1 0 4 0 8 406 404 402 400 398 396 394 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 352 350 348 344 342 340 338 336 334 332 330 328 326 404 402 400 398 396 394 392 390 388 386 384 382 380 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 85C 'C' 47C 'C/D' 62D'B' 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 1146 10 TWIN 30" TREE 32" TREE 32" TREE 46" TRIPLE TREE 14" TREE CT6011 CL&P 6010 IP S CL&P 6009 W/UG UPOLE CP6008 6007 6007 EXISTING BITUMINOUS DRIVEWAY HELT 9258 9190 CL&P 9787 EVS 9788 EXI S T I N G RES I D E N C E EX I S T I N G RE S I D E N C E EX I S T I N G DE C K CAROL DRI V E SH A R P H I L L R O A D DH EXISTING CB TYPE "C" TF=398.40 EXISTING CB TYPE "C" TF=398.47 INV (S) 15" RCP=393.97 INV (SW) 15" RCP=393.97 INV (NE) 15" RCP=393.82 EXISTING CB TYPE "C" TF=366.15 INV (S) 6" PVC=363.05 INV (N) 15" RCP=365.15 EXISTING CB TYPE "C" TF=365.97 INV (S) 15" RCP=360.97 INV (SW) 15" RCP=360.97 INV (NE) 15" RCP=393.87 EXISTING CB TYPE "C" TF=337.65 EXISTING CB TYPE "CL" TF=435.17 1146 10 TWIN EXISTING 1 STORY RESIDENCE S5 5 ° 0 9 ' 5 7 " W 15 0 . 1 6 ' N5 5 ° 0 9 ' 5 7 " E 14 9 . 4 7 ' N33°15'22"W 100.20' 84B 'C' 84B 'C' EXISTING SHED EXISTING BIT. DRIVEWAY WF#2-2 WF#2-1 WF#2-4 WF#2-3 DH DH DH DH EXISTING DILAPIDATED SHED EXISTING SHED 47C 'C/D' 47C 'C/D' 85C 'C' 46B 'C/D' 47C 'C/D' MON MON MON MONMON MON MON MONMON MON MONMON TP#101 TP#102 TP#103 TP#104 TP#105 CB-1 CB-2 CB-3 CB-4 CB-5 (CHANGE TO "CL" TOP) YD-1 YD-2 YD-3 YD-4 YD-5 YD-6 YD-7 YD-8 OCS-1 OCS-2 FES-3 OCS-3 FES-4 3 6 5 3 7 0 3 8 0 3 9 0 380 375 385 385 380 405 405 380 385 375 370 365 380 3 8 0 370 375 375 370 370 365 380 360370 365 360 3 7 0 3 6 5 3 6 0 355 38 0 375 366 367 368 364 363 361 3 6 3 3 6 4 3 6 6 3 6 7 3 6 8 3 6 9 3 7 1 3 7 2 3 7 3 3 7 4 3 7 8 3 8 2 383 3 8 4 3 8 6 397 38 3 397 379 381 382 384 369 364 364 363 366 FES-2 354 BIORETENTION BASIN 'C' TOP OF BERM=392.00 TOP OF SPILLWAY=391.50 BOTTOM OF BASIN=388.00 3 6 1 365 FES-5 DMH-1 343.5 345 350 355357357 355 FES-1 SEDIMENT FOREBAY/ WATER QUALITY BASIN TOP OF BERM=357.00 TOP OF SPILLWAY=356.5 BOTTOM O F BASIN=354.00 BIORETENTION BASIN 'B' TOP OF BERM=344.00 TOP OF SPILLWAY=343.00 BOTTOM OF BASIN=338.00 BIORETENTION BASIN 'A' TOP OF BERM=347.50 TOP OF SPILLWAY=347.00 BOTTOM O F BASIN=343.50 FES-6 335 340 344344 340338 338 340 345347 347 345 332 334 3 4 5 3 4 8 3 4 4 3 4 4 3 4 5 3 4 7 3 4 7 3 4 5 338340 344344 3 6 2 3 7 5 3 7 6 3 7 7 3 7 9 3 8 1 3 8 2 3 8 3 3 8 5 3 8 7 3 8 8 3 8 9 3 9 0 3 9 1 3 9 2 3 9 3 3 9 4 3 9 5 395 388 389 390 391 392 393 394 395 397 39 8 405 410 415 4 0 4 403 40 1 39 9 410 415 410 405 120 415 410 405 4 0 5 4 1 0 415 390 390 390 385 394 393 393 391 3 9 5 391 390 383 377 3 9 3 3 8 7 3 8 1 3 6 9 3 7 5 394 3 9 4 400 4 0 0 395 395 390 388 392 392 384 382384 D 3 9 6 3 9 7 NEW STORMWATER MANAGEMENT AREA 'A' - 24"(W) INFILTRATION TRENCH. TOP OF STONE VARIES WITH GRADE (MAX.=365.5; MIN.=361.0) BOTTOM OF STONE=360.0 EN SW 50025 SCALE IN FEET 50 DRAINAGE STRUCTURE AND PIPE TABLE STARTING STRUCTURE DRAINAGE PIPE ENDING STRUCTURESTRUCTUREELEVATIONS CB-2 TYPE 'C' CB W/ 2' SUMP TF=393.10 15" INV (SE)=388.10 219 L.F. 15" HDPE PIPE S=0.0644 FT./FT.CB-3 CB-1 TYPE 'C' CB W/ 4' SUMP & OUTLET HOOD TF=394.00 15" INV (NW)=390.65 139 L.F. 15" HDPE PIPE S=0.0140 FT./FT.DMH-1 CB-3 TYPE 'C' CB W/ 2' SUMP TF=378.00 15" INV (NW)=374.00 15" INV (SE)=374.00 209 L.F. 15" HDPE PIPE S=0.0713 FT./FT.CB-4 CB-4 TYPE 'C' CB W/2' SUMP TF=363.10 15" INV (NW)=359.10 18" INV (SE)=358.85 97 L.F. 18" HDPE PIPE S=0.0294 FT./FT.CB-5 CB-5 TYPE 'C' CB W/ 4' SUMP AND OUTLET HOOD TF=360.10 12" INV (SW)=356.50 18" INV (NW)=356.00 24" INV (NE)=355.50 26 L.F. 24" HDPE PIPE S=0.0192 FT./FT.FES-1 FES-1 FLARED END SECTION INV=355.00 ---SEDIMENT FOREBAY/ WATER QUALITY BASIN SEDIMENT FOREBAY/ WATER QUALITY BASIN TOP OF BERM=357.00 BOT. OF BASIN=354.00 ---OCS-1 OCS-1 OUTLET CONTROL STRUCTURE TOP OF FRAME=356.25 48"x6" ORIFICE=355.75 24" INV=345.00 50 L.F. 24" HDPE PIPE S=0.0300 FT./FT.FES-2 FES-2 FLARED END SECTION INV=343.50 ---BIORETENTION BASIN 'A' BIORETENTION BASIN 'A'TOP OF BERM=347.50BOT. OF BASIN=343.50 ---OCS-2 FES-3 FLARED END SECTION INV=338.00 ---BIORETENTION BASIN 'B' BIORETENTION BASIN 'B'TOP OF BERM=344.00 BOT. OF BASIN=338.00 ---OCS-3 YD-1 YARD DRAIN TF=389.70 12" INV (SE)=386.10 105 L.F. 12" HDPE PIPE S=0.0629 FT./FT.YD-2 DRAINAGE STRUCTURE AND PIPE TABLE STARTING STRUCTURE DRAINAGE PIPE ENDING STRUCTURESTRUCTUREELEVATIONS YD-2 YARD DRAIN TF=382.50 12" INV (NW)=379.50 12" INV (SE)=379.50 84 L.F. 12" HDPE PIPE S=0.0726 FT./FT.YD-3 YD-3 YARD DRAIN TF=376.40 12" INV (NW)=373.40 12" INV (SE)=373.40 108 L.F. 12" HDPE PIPE S=0.0722 FT./FT.YD-4 YD-4 YARD DRAIN TF=368.60 12" INV (NW)=365.60 12" INV (SE)=365.60 65 L.F. 12" HDPE PIPE S=0.0754 FT./FT.YD-5 YD-5 YARD DRAIN TF=363.70 12" INV (NW)=360.70 12" INV (SE)=360.70 89 L.F. 12" HDPE PIPE S=0.0258 FT./FT.YD-6 YD-6 YARD DRAIN TF=361.40 12" INV (NW)=358.40 12" INV (S)=358.40 12" INV (NE)=358.40 27 L.F. 12" HDPE PIPE S=0.0704 FT./FT.CB-5 YD-7 YARD DRAIN TF=364.80 12" INV (N)=361.80 61 L.F. 12" HDPE PIPE S=0.0328 FT./FT.YD-8 YD-8 YARD DRAIN TF=362.80 12" INV (N)=359.80 12" INV (S)=359.80 95 L.F. 12" HDPE PIPE S=0.0147 FT./FT.YD-6 DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : DR A I N A G E & S T O R M W A T E R MA N A G E M E N T P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 DSW-1 7 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 6 - 0 7 _ G R A D I N G P L A N . D W G T a b : 7 D R A I N A G E & S T O R M W A T E R M A N A G E M E N T P L A N S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 4 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 8 P M FES-4 FLARED END SECTION INV=334.00 ------ DRAINAGE NOTES: 1.CONTRACTOR SHALL CLEAN ALL PROPOSED STRUCTURES AND PIPES UPON COMPLETION OF CONSTRUCTION. 2.CONTRACTOR TO VERIFY ALL EXISTING PIPE CONNECTIONS AND INVERTS. ANY CONFLICTS SHOULD BE EXPRESSED TO OWNER AND THE DESIGN ENGINEER. STORMWATER MANAGEMENT SYSTEM MAINTENANCE PLAN CONTINUED: 3.BIORETENTION BASINS A.THE BIORETENTION BASINS SHALL BE CLEANED AT THE END OF CONSTRUCTION ONCE THE CONTRIBUTING AREAS ARE FULLY STABILIZED. B.FOLLOWING CONSTRUCTION, THE BIORETENTION BASINS SHALL BE INSPECTED EVERY SIX MONTHS AND/OR AFTER STORM EVENTS OF 2 INCHES OF RAINFALL OR GREATER. INSPECTIONS SHALL INCLUDE THE FOLLOWING: ·INSPECT FILTER MEDIA STANDING WATER OR OTHER EVIDENCE OF CLOGGING. ·CHECK FOR SEDIMENT ACCUMULATION, TRASH, AND DEBRIS. ·CHECK FOR BLOCKAGES, STRUCTURAL INTEGRITY, AND EVIDENCE OF EROSION AT INLET, OUTLET, AND OVERFLOW SPILLWAY. C.REGULAR MAINTENANCE SHALL INCLUDE THE FOLLOWING: ·BASIN FLOOR/SIDE SLOPES SHALL BE MOWED 6" TO 8" AS NEEDED. GRASS CLIPPINGS, LEAVES AND ACCUMULATED SEDIMENT ANDDEBRIS SHALL BE REMOVED DURING THE SUMMER, HOWEVER, PLANT MATTER SHALL BE LEFT IN PLACE OVER WINTER MONTHS TO INSULATE THE SOIL AND ADD ORGANIC MATTER TO THE SOIL. REMOVAL CRITERIA SHALL INCLUDE WHEN PLANT MATTER IS SMOTHERING OR KILLING VEGETATION AND AESTHETICS. ·REMOVE SEDIMENT GREATER THAN 1.0 INCH DEEP IN MARCH-APRIL IN THE FILTER MEDIA BED IN A MANNER TO MINIMIZE DAMAGE TO VEGETATION. ·INSPECT SOIL AND REPAIR ERODED AREAS SEASONALLY OR AS NECESSARY. ·REMOVE ANY INVASIVE SPECIES (INCLUDING ROOTS) THAT HAVE BECOME ESTABLISHED WITHIN THE BASIN AND EMBANKMENTS. ·IF THERE IS AN ACCUMULATION OF ORGANIC DEBRIS OR SEDIMENT ON THE FLOOR OF THE BASIN, OR IF PONDED WATER IS REGULARLY OBSERVED MORE THAN 48 HOURS AFTER A RAINFALL EVENT, THE TOP 6" SHALL BE REMOVED AND THE EXPOSED SOIL SURFACE ROTOTILLED TO A DEPTH OF 12". SEDIMENTATION SHOULD BE REMOVED WHEN IT IS VISIBLY DRY AND READILY SEPARATES FROM THE BASIN FLOOR TO MINIMIZE SMEARING. AFTER THIS WORK HAS BEEN DONE, THE BOTTOM OF THE BASIN SHALL BE RESTORED TO ITS ORIGINAL CONDITION. ·NO PESTICIDES OR NON-ORGANIC FERTILIZERS SHALL BE USED IN AREAS DRAINING TO THE BIORETENTION BASIN. STORMWATER MANAGEMENT SYSTEM MAINTENANCE PLAN: 1.GENERAL A.PAVEMENT SWEEPING SHALL BE PERFORMED AT LEAST ONCE PER YEAR, PREFERABLY AT THE END OF THE WINTER SANDING SEASON AND IN CONJUNCTION WITH INSPECTION AND CLEANING OF ALL STORM DRAINAGE STRUCTURES AND FEATURES. 2.CATCH BASINS AND MANHOLES A.A CONNECTICUT-LICENSED HAULER SHALL PUMP THE SUMPS OF ON-SITE CATCH BASINS AND MANHOLES, AND SHALL DISPOSE OF THE PUMPING LEGALLY. ROAD SAND MAY BE REUSED FOR WINTER SANDING, BUT MAY NOT BE STORED ON-SITE. AS PART OF THE HAULING CONTRACT, THE HAULER SHALL NOTIFY THE PROPERTY OWNER IN WRITING WHERE THE MATERIAL IS BEING DISPOSED. B.FOR THE FIRST 2 YEARS, EACH CATCH BASIN SHALL BE INSPECTED EVERY 4 MONTHS, WITH ONE INSPECTION OCCURRING DURING THE MONTH OF APRIL. ANY DEBRIS OCCURRING WITHIN 1-FT. FROM THE BOTTOM OF EACH SUMP SHALL BE REMOVED BY VACUUM “VACTOR” TYPE OF MAINTENANCE EQUIPMENT. AFTER THE FIRST 2 YEARS THE INSPECTION SCHEDULE MAY BE ADJUSTED TO MEET ACTUAL OPERATING CONDITIONS, HOWEVER, ONE INSPECTION SHALL ALWAYS BE CONDUCTED IN APRIL. ALL SEDIMENT SHALL BE DISPOSED IN ACCORDANCE WITH ALL RULES AND REGULATIONS OF THE CT DEEP. GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY. 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T DMH-1 DRAINAGE MANHOLE TF=394.20 15" INV (SE)=388.70 15" INV (N)=388.70 46 L.F. 15" HDPE PIPE S=0.0143 FT./FT.FES-5 FES-5 FLARED END SECTION INV=388.00 ---BIORETENTION BASIN 'C' OCS-4 OUTLET CONTROL STRUCTURE TOP OF FRAME=391.25 24"x6" ORIFICE=390.7518"x4" ORIFICE=390.00 6"x4" ORIFICE=389.00 15" INV=385.50 32 L.F. 15" HDPE PIPE S=0.0156 FT./FT.FES-6 FES-6FLARED END SECTION INV=385.00 ------ OCS-2 OUTLET CONTROL STRUCTURE TOP OF FRAME=346.75 48"x6" ORIFICE=346.25 24" INV=339.00 38 L.F. 24" HDPE PIPE S=0.0263 FT./FT.FES-3 OCS-3 OUTLET CONTROL STRUCTURE TOP OF FRAME=342.00 48"x6" ORIFICE=340.90 48"x6" ORIFICE=339.15 21" INV=335.00 38 L.F. 24" HDPE PIPE S=0.0263 FT./FT.FES-4 CONCEPTUAL LOCATION OF NEW DRILLED WELL (TYP.) CB-1 CB-2 CB-3 CB-4 CB-5 YD-1 YD-2 YD-3 YD-4 YD-5 YD-6 YD-7 YD-8 3 6 5 3 7 0 3 8 0 3 9 0 380 375 385 385 380 405 405 380 385 375 370 365 380 3 8 0 370 375 375 370 370 365 380 360370 365 360 3 7 0 3 6 5 3 6 0 355 38 0 375 365 345 350 355 355 335 340 344 340 340 345 345 332 334 3 4 5 3 4 5 3 4 5 340 3 7 5 3 8 5 3 9 0 3 9 5 395 405 410 415 410 415 410 405 120 415 410 405 4 0 5 4 1 0 415 390 390 390 385 3 9 5 400 4 0 0 395 395 390 D OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OHE OH E OH E OH E OH E OH E OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X SA N SAN SA N SA N SAN SA N SA N SAN SA N SAN SA N SAN SA N SAN SAN SA N SAN SA N SA N SAN STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S CL&P 3895 418 416 414 412 410 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 4 1 4 41 2 4 1 0 4 0 8 406 404 402 400 398 396 394 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 352 350 348 344 342 340 338 336 334 332 330 328 326 404 402 400 398 396 394 392 390 388 386 384 382 380 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 EXISTING SMH TF=401.34 INV 10" PVC=394.44 INV 10" PVC=389.86 CT6011 CL&P 6010 IP S EXISTING SMH TF=369.66 FL=359.16 CL&P 6009 W/UG UPOLE CP6008 6007 6007 EXISTING SMH TF=337.17 FL=328.05 HELT 9258 9190 CL&P 9787 EVS 9788 CAROL DRI V E SH A R P H I L L R O A D DH EXISTING CB TYPE "C" TF=337.01 WF#2-2 WF#2-1 WF#2-4 WF#2-3 DH DH DH DH MON MON MON MONMON MON MON MONMON MON MONMON W 1ST FL F F E = 3 8 2 . 0 BSMT=37 2 . 0 1ST F L F F E = 3 6 7 . 8 GAR A G E = 3 6 4 . 8 1ST F L F F E = 3 6 9 . 7 GAR A G E = 3 6 6 . 7 1ST FL FFE=368.6 GARAGE=365.6 1ST FL F F E = 3 8 0 . 0 GARAGE= 3 7 8 . 0 1ST FL F F E = 3 7 3 . 4 GARAGE= 3 7 0 . 4 1ST FL F F E = 3 8 7 . 9 GARAGE= 3 8 3 . 9 1S T F L F F E = 4 0 1 . 0 GA R A G E = 3 9 8 . 5 1ST FL F F E = 3 9 3 . 6 GARAGE= 3 9 1 . 6 1ST FL FFE=399.4 GARAGE=396.91ST FL FFE=400.0 GARAGE=398.0 1ST FL FFE=401.0 GARAGE=398.5 1ST FL FFE=407.3 GARAGE=404.3 1ST F L F F E = 3 9 9 . 0 GAR A G E = 3 9 7 . 0 1 S T F L F F E = 4 0 0 . 0 G A R A G E = 3 9 8 . 0 1ST F L F F E = 3 9 4 . 0 GAR A G E = 3 9 2 . 0 1ST FL FFE=395 . 5 GARAGE=393.5 BSMT=385.5 1ST F L F F E = 3 9 6 . 0 GARA G E = 3 9 4 . 0 BSMT = 3 8 6 . 0 1ST FL F F E = 3 9 0 . 0 GARAGE = 3 8 8 . 0 BSMT=38 0 . 0 1ST FL F F E = 3 8 4 . 0 GARAGE = 3 8 2 . 0 BSMT=37 4 . 0 1ST FL F F E = 3 7 8 . 0 GARAGE= 3 7 6 . 0 BSMT=36 8 . 0 1ST FL F F E = 3 7 2 . 0 GARAGE= 3 7 0 . 0 BSMT=36 2 . 0 1ST FL FFE = 3 6 7 . 0 GARAGE=3 6 5 . 0 BSMT=357. 0 1ST FL FFE=396.0 GARAGE=394.0 BSMT=386.0 W W W W W W W W W W W W W W W W W W W W W W S SS S S S S S SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN SAN SAN S OH E NEW OVERHEAD ELECTRIC TO NEW UTILITY POLE SMH-9 SMH-8 SMH-7SMH-6 SMH-5 SMH-1 SAN SMH-4 SMH-3 SMH-2 CROSSING 12" HDPE INV=357.35 8" SAN. CROWN=356.0 ETC ETC ETC ETC ETC ETC ETC ETC ETCETCETC E T C ETC ETC ET C ET C ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC NEW TRANSFORMER(S) (QUANTITY AND FINAL LOCATION(S) TO BE DETERMINED BY EVERSOURCE) NEW UTILITY POLE NEW UNDERGROUND ELECTRIC, TELEPHONE AND CABLE SERVICES IN SCH. 40 PVC CONDUITS CONCEPTUAL NEW 4" SDR 35 PVC SANITARY SEWER LATERAL WITH BENDS AND CLEANOUTS TO GRADE AS NECESSARY (TYP.) (SLOPE=1/4"/FT. MIN.) NEW 8" SDR35 PVC SANITARY SEWER MAIN (MIN. SLOPE REQUIRED =0.004 FT./FT.) 50025 SCALE IN FEET 50 EN SW UTILITY NOTES: 1.ALL NEW ON-SITE UTILITIES, INCLUDING CATV, SHALL BE LOCATED UNDERGROUND. 2.ALL UTILITY WORK SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 3.ELECTRIC, TELEPHONE, CABLE, AND SANITARY SEWER SERVICES SHALL CONFORM TO THE POLICIES AND PRACTICES OF THE APPROPRIATE UTILITY AUTHORITY. ELECTRICAL SERVICES ARE PROVIDED BY EVERSOURCE; SANITARY SEWER SERVICES ARE PROVIDED BY THE TOWN OF MONTVILLE. 4.ALL UTILITIES SHALL BE STRUCTURALLY SUPPORTED TO MINIMIZE DISRUPTION FROM SETTLEMENT OF UNDERLYING SOIL. 5.SANITARY SEWER SERVICES SHALL BE SDR 35 PVC PIPE. 6.UTILITY SERVICE SIZES, MATERIALS, AND INSTALLATIONS SHALL BE APPROVED AND INSPECTED BY THE APPROPRIATE UTILITY COMPANY. 7.LOCATION AND SIZE OF ALL BUILDING UTILITY CONNECTIONS SHALL BE COORDINATED WITH BUILDING ARCHITECTURAL PLANS AND CUSTODIAL UTILITY AUTHORITY AT THE TIME OF INDIVIDUAL LOT DEVELOPMENT. 8.MINIMUM 5' SEPARATION BETWEEN ELECTRIC AND ALL OTHER PIPES SUCH AS WATER, SANITARY SEWER AND DRAINS. A MINIMUM OF 12" SHALL BE PROVIDED BETWEEN ELECTRICAL LINES AND TELEPHONE/CABLE LINES. 9.ALL ELECTRIC FACILITIES SUCH AS CONDUITS AND PRIMARY & SECONDARY HANDHOLES SHALL CONFORM TO THE REQUIREMENTS OF EVERSOURCE. DRAINAGE STRUCTURE AND PIPE TABLE STARTING STRUCTURE DRAINAGE PIPE ENDING STRUCTURESTRUCTUREELEVATIONS SMH2 SANITARY MANHOLE TF=394.25 8" INV (NW)=385.10 8" INV (SE)=385.00 50 LF 8" SDR35 PVC PIPE S=0.0216 FT./FT.SMH3 SMH1 SANITARY MANHOLE TF=394.75 8" INV (SE)=388.30 142 LF 8" SDR35 PVC PIPES=0.0225 FT./FT.SMH2 SMH3 SANITARY MANHOLE TF=391.65 8" INV (NW)=383.90 8" INV (SE)=383.80 72 LF 8" SDR35 PVC PIPE S=0.0653 FT./FT.SMH4 SMH4 SANITARY MANHOLE TF=386.50 8" INV (NW)=379.10 8" INV (SE)=378.90 131 LF 8" SDR35 PVC PIPE S=0.0649 FT./FT.SMH5 SMH5 SANITARY MANHOLE TF=377.00 8" INV (NW)=370.40 8" INV (SE)=370.20 204 LF 8" SDR35 PVC PIPE S=0.0676 FT./FT.SMH6 SMH6SANITARY MANHOLE TF=362.65 8" INV (NW)=356.40 8" INV (SE)=356.30 66 LF 8" SDR35 PVC PIPE S=0.0121 FT./FT.SMH7 SMH7 SANITARY MANHOLE TF=360.40 8" INV (NW)=355.50 8" INV (S)=355.40 213 LF 8" SDR35 PVC PIPE S=0.0108 FT./FT.SMH8 SMH8 SANITARY MANHOLE TF=365.65 8" INV (N)=353.10 8" INV (SE)=353.00 70 LF 8" SDR35 PVC PIPE S=0.0114 FT./FT.SMH9 SMH9 SANITARY MANHOLE TF=364.50 NEW 8" INV (NW)=352.20 EX. 10" INV (W)=352.2± EX. 10" INV (E)=351.7± ---EXISTING SANITARY LINE DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : UT I L I T Y P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 UT-1 8 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 8 _ U T I L I T Y P L A N . D W G T a b : 8 U T I L I T Y S a v e d : 8/ 1 5 / 2 0 2 5 1 2 : 3 2 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY. OHE OH E OHE OH E OH E OH E OHE OH E OH E OHE OH E OH E OH E OHE OH E OHE OH E X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM S S S S 410 400 390 380 4 1 0 400 39 0 380 370 360 350 340 330 400 390 380 370 360 350 340 S EXI S T I N G RES I D E N C E EX I S T I N G RE S I D E N C E EX I S T I N G DE C K CAROL DRI V E SH A R P H I L L R O A D N/F LUCILLE R. GREEN 64 SHARP HILL ROAD N/F JEAN PIERRE & JANET LESIEUR 48 SHARP HILL ROAD N/F ALEX J. GRAF 42 SHARP HILL ROAD N/F BRENT A & DIANNE L. DEVINE, TRUSTEES 32 SHARP HILL ROAD N/F NATHAN MCKELVEY & KATHERINE E. MCKELVEY 39 SHARP HILL ROADN/F KEVIN G. & DARLENE A. MCCARTHY 392 MAPLE AVENUE N/F ADVANCED ASSOCIATES LLC 410 MAPLE AVENUE EXISTING 1 STORY RESIDENCE EXISTING SHED WF#2-2 WF#2-1 WF#2-4 WF#2-3 N/F BRUCE & LISA DUCHESNEAU 45 SHARP HILL ROAD D TEMPORARY ANTI-TRACKING PAD CONSTRUCTION ENTRANCE EROSION CONTROL MATTING ON DISTURBED SLOPES 3H:1V OR STEEPER (TYP.) SILT SACK INLET PROTECTION (TYP.) TEMPORARY SOIL STOCKPILE AREA (TYP.) APPROXIMATE LIMITS OF CLEARING NECESSARY TO CONSTRUCT PRIVATE ROAD AND ASSOCIATED UTILITIES/STORMWATER MANAGEMENT SYSTEM. TEMPORARY SEDIMENT TRAP TOP OF BERM=363.0 TOP OF SPILLWAY=362.0 BOTTOM OF BASIN=358.0 STORAGE CAPACITY PROVIDED (BELOW SPILLWAY)=16,526 CF STORAGE CAPACITY REQUIRED (BELOW SPILLWAY)=16,462 CF (SEE DETAILS FOR SIZING REQUIREMENTS) 3 8 0 355 361 3 8 4 3 7 9 354 3 6 1 343.5 345 350 357357 355 335 340 344344 340338 338 340 345347 347 345 332 334 3 4 5 3 4 8 3 4 4 3 4 4 3 4 5 3 4 7 3 4 7 3 4 5 338340 344344 3 6 2 3 7 5 3 7 7 410 420 415 362 3 6 8 3 6 9 3 7 0 3 7 1 3 7 2 3 7 3 3 7 4 3 7 6 3 7 8 3 8 1 3 8 2 3 8 3 3 8 5 3 8 6 368 3 8 7 3 8 8 3 8 9 3 9 0 3 9 1 3 9 2 3 9 3 3 9 4 3 9 5 395 394 392 390 388 386388 392 392 384 389 390 391 392 393 394 39 5 39 5 408 406 404 402 400 398 396 SF SF SF SF SF SF SF SF SFSF SF SF SFSF SF SFSF SF SF S F SFSF SF SF SF SF S F SF SF S F SF SF SF SF SF S F SF SF SFSF SF SF SF SF SF SF SFSF SF SF S F SF SF SF SF SFSF SF SF SF SF SF SF SF SF TEMPORARY SEDIMENT TRAP DRAINAGE AREA TEMPORARY DIVERSION SWALE 3 6 7 3 6 6 3 6 5 3 6 4 3 6 3 363 364 365 366 362 367 401 395 TEMPORARY HAYBALE BACKED SEDIMENT FENCE (TYP.) TEMPORARY SEDIMENT FENCE (TYP.) EN SW 50025 SCALE IN FEET 50 SOIL EROSION & SEDIMENT CONTROL NOTES: 1.THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT ADJACENT PROPERTIES FROM ANY EROSION AND/OR SEDIMENTATION. REFER TO SOIL EROSION & SEDIMENT CONTROL PLAN AND NARRATIVE FOR PROPOSED SOIL EROSION & SEDIMENT CONTROL MEASURES. 2.REFER TO THE SOIL EROSION & SEDIMENT CONTROL NARRATIVE FOR ADDITIONAL INFORMATION. 3.ZONING ENFORCEMENT OFFICER MAY REQUIRE ADDITIONAL SOIL EROSION AND SEDIMENTATION CONTROLS AS NEEDED. DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : SO I L E R O S I O N & S E D I M E N T C O N T R O L P L A N 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 1" = 50' SMM 7/10/2025 SMM 7/10/2025 SE-1 9 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 0 9 _ S E S C P L A N . D W G T a b : 9 S E S C S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 5 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T GENERAL NOTES: 1.THE APPLICANT IS MT KINEO BUILDERS, LLC WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. THE PROPERTY OWNER IS R&N HOLDING COMPANY WITH A MAILING ADDRESS OF P.O. BOX 246, WEST MYSTIC, CT 06388. 2.THE SUBJECT PARCEL IS IDENTIFIED AS LOT 63 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 23. THE DEED REFERENCE OF THE PROPERTY IS VOLUME 708 PAGE 1032. 3.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. 4.THE PARCEL IS LOCATED WITHIN THE TOWN OF MOTVILLE RESIDENTIAL 'R-20' ZONING DISTRICT. THE PROPERTY IS NOT LOCATED WITHIN A FEMA FLOOD HAZARD ZONE. 5.AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 6.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE INLAND WETLANDS & WATERCOURSES COMMISSION FOR A WETLANDS PERMIT APPLICATION, AND THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION FOR A SUBDIVISION APPPLICATION. 7.EACH NEW BUILDING LOT WILL BE SERVED BY PRIVATE WELLS AND PUBLIC SANITARY SEWER. 8.INLAND WETLANDS WERE FLAGGED BY IAN COLE, WETLAND SCIENTIST AND REGISTERED SOIL SCIENTIST, IN SEPTEMBER 2024 AND WERE LOCATED BY BOUNDARIES, LLC IN JANUARY 2025. 9.ELEVATIONS SHOWN HEREON ARE BASED ON NAVD-88 DATUM. CONSTRUCTION NOTES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 2.THE LOCATIONS OF SUBSURFACE UTILITIES SHOWN HEREON ARE APPROXIMATE. THE ACTUAL LOCATION OF SUBSURFACE UTILITIES MAY VARY FROM THOSE INDICATED AND ALL UNDERGROUND UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING EXISTING UTILITIES PRIOR TO BEGINNING SITE WORK. 3.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION. 4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION. 5.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE. 6.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF PUBLIC WORKS. 7.EXISTING DRAINAGE PATTERNS SHALL BE SUBSTANTIALLY MAINTAINED. THE CONTRACTORSHALL GRADE THE PROPERTY IN SUCH A MANNER TO MAINTAIN EXISTING LOCAL DRAINAGE PATTERNS AND TO PREVENT EXCESS RUNOFF AND/OR PONDING ON ADJACENT PROPERTIES BOTH DURING AND AFTER CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL DISTURBED AREAS TO THEIR PRE-CONSTRUCTION CONDITION OR BETTER ONCE ALL WORK IS COMPLETE. 9.HOURS OF CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 6:00 P.M. MONDAY THROUGH FRIDAY, AND 8:00 A.M. TO 6:00 P.M. SATURDAY. NO CONSTRUCTION ACTIVITY SHALL TAKE PLACE ON SUNDAYS. ADDITIONALLY, NO EXTERIOR LIGHTING FOR CONSTRUCTION PURPOSES, FREESTANDING OR OTHERWISE, IS APPROVED WITH THIS APPLICATION. 10.DELIVERIES OF MATERIALS/EQUIPMENT TO THE SITE RELATED TO THIS CONSTRUCTION PROJECT ARE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY TO SATURDAY.             RoadHillSharp Revisions SHEET NO. 10 Im p r o v e m e n t L o c a t i o n & T o p o g r a p h i c S u r v e y "S i g h t L i n e D e m o n s t r a t i o n P l a n " Pr e p a r e d F o r Mt K i n e o B u i l d e r s , L L C 47 S h a r p H i l l R o a d - M o n t v i l l e , C o n n e c t i c u t July 2025 JOB I.D. NO. P: \ C I V I L 3 D P R O J E C T S \ 2 0 2 4 \ 2 4 - 3 5 1 4 M T K I N E O S H A R P H I L L \ D W G \ D E S I G N \ 1 0 S I G H T L I N E D E M O N S T R A T I O N P L A N R E V A . D W G 24-3514 DATE: SCALE: 16 1" = 30' ©2025 BOUNDARIES LLC THIS DRAWING IS THE PROPERTY OF BOUNDARIES LLC AND HAS BEEN SPECIFICALLYPREPARED FOR THE OWNER OF THIS PROJECT, AT THIS SITE, AND IS NOT TO BEDUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT,LOCATION OR OWNER WITHOUT THE EXPRESSED WRITTEN CONSENT OFBOUNDARIES LLC. NOT VALID WITHOUT LIVE SIGNATURE AND EMBOSSED SEAL. GRAPHIC SCALE PROFILE - SIGHT LINE EAST HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 10' PROFILE - SIGHT LINE WEST HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 10' Rev. "A" 8-15-2025 Per Town Comments EL E V A T I O N EL E V A T I O N STATION STATION 340 350 360 370 380 390 400 410 340 350 360 370 380 390 400 410 -0+500+001+002+003+004+005+006+007+008+009+0010+0010+50 -0+500+001+002+003+004+005+006+007+008+009+0010+0010+50 142 LF 8" SDR35 PVCS=0.0225 F T / F T CB-6 TF=363.6 15" INV OUT=359.6CB-5 TF=360.1 12" INV IN (SW)=356.5 15" INV IN=356.0 24" INV OUT=355.5 CB-4 TF=363.1 15" INV IN=359.1 18" INV OUT=359.1 CB-3 TF=378.0 15" INV IN=374.0 15" INV OUT=374.0 CB-2 TF=393.1 15" INV OUT=388.1 CB-1 TF=394.0 15" INV OUT=390.65 PROPOSED SURFACE EXISTING SURFACE -3.00% 7.0 0 % -2.00% NEW 'SMH9' TF=364.50 8" INV IN=352.2 10" INV IN=352.2± 10" INV OUT=351.7± NEW 'SMH2' TF=394.25 8" INV IN=385.10 8" INV OUT=385.00 NEW 'SMH1' TF=394.75 8" INV OUT=388.30 NEW 'SMH3' TF=391.65 8" INV IN=383.90 8" INV OUT=383.80 50 LF 8"SDR35 PV CS=0.0220 F T / F T NEW 'SMH4' TF=386.50 8" INV IN=379.10 8" INV OUT=378.90 72 L F 8 " SD R 3 5 P V C S=0. 0 6 5 3 F T / F T NEW 'SMH5' TF=377.00 8" INV IN=370.40 8" INV OUT=370.20 131 L F 8 " SD R 3 5 P V C S=0 . 0 6 4 9 F T / F T NEW 'SMH6' TF=362.65 8" INV IN=356.40 8" INV OUT=356.30 204 L F 8 " SD R 3 5 P V C S=0. 0 6 7 6 F T / F T NEW 'SMH7' TF=360.40 8" INV IN=355.50 8" INV OUT=355.40 66 LF 8" SDR35 PVC S=0.0121 FT/FT NEW 'SMH8' TF=365.65 8" INV IN=353.10 8" INV OUT=353.00 213 LF 8" SDR35 PVC S=0.0108 FT/FT 70 LF 8"SDR35 PVC S=0.0114 FT/FT AD = -9.00% K = 22.23 200.00' VC HIGH POINT STA. = 8+85.45 HIGH POINT ELEV. = 395.68 BV C S : 7 + 2 9 . 8 7 BV C E : 3 9 0 . 2 3 EV C S : 9 + 2 9 . 8 7 EV C E : 3 9 5 . 2 3 AD = 10.00% K = 15.47 154.72' VC LOW POINT STA. = 2+48.24 LOW POINT ELEV. = 360.31 BV C S : 2 + 0 1 . 8 1 BV C E : 3 6 1 . 0 0 EV C S : 3 + 5 6 . 5 3 EV C E : 3 6 4 . 1 0 OH E OHE OH E OH E OH E OHE OH E OH E OH E X SAN SA N SAN SA N SA N SAN SA N SAN SAN SA N STM STM STM STM STM STM STM STM STM 408 406 404 402 400 398 396 394 392 390 388 386 384 382 380 378 376 392 39 0 38 8 386 38 4 382 380 378 376 374 372 370 368 366 364 362 360 358 356 354 3 7 8 37 6 374 372 370 368 366 364 362 360 358 356 354 352 TREE S EXISTING SMH TF=369.66 FL=359.16 SH A R P H I L L R O A D EXISTING CB TYPE "C" TF=366.15 INV (S) 6" PVC=363.05 INV (N) 15" RCP=365.15 EXISTING CB TYPE "C" TF=365.97 INV (S) 15" RCP=360.97 INV (SW) 15" RCP=360.97 INV (NE) 15" RCP=393.87 EXISTING BIT. DRIVEWAY EXISTING SHED W 1ST FL F F E = 3 8 2 . 0 BSMT=37 2 . 0 1ST F L F F E = 3 6 7 . 8 GAR A G E = 3 6 4 . 8 1ST F L F F E = 3 6 9 . 7 GARA G E = 3 6 6 . 7 1ST FL FFE=368.6 GARAGE=365.6 1ST FL F F E = 3 8 0 . 0 GARAGE= 3 7 8 . 0 1ST FL F F E = 3 7 3 . 4 GARAGE= 3 7 0 . 4 1ST FL F F E = 3 8 7 . 9 GARAGE = 3 8 3 . 9 1ST FL F F E = 3 9 3 . 6 GARAGE= 3 9 1 . 6 1ST FL FFE=399.4 GARAGE=396.91ST FL FFE=400.0 GARAGE=398.0 1ST F L F F E = 3 9 9 . 0 GAR A G E = 3 9 7 . 0 1 S T F L F F E = 4 0 0 . 0 G A R A G E = 3 9 8 . 0 1ST F L F F E = 3 9 4 . 0 GAR A G E = 3 9 2 . 0 1ST FL FFE=395.5 GARAGE=393.5 BSMT=385.5 1ST FL F F E = 3 9 6 . 0 GARA G E = 3 9 4 . 0 BSMT = 3 8 6 . 0 1ST FL F F E = 3 9 0 . 0 GARAGE = 3 8 8 . 0 BSMT=38 0 . 0 1ST FL F F E = 3 8 4 . 0 GARAGE= 3 8 2 . 0 BSMT=37 4 . 0 1ST FL F F E = 3 7 8 . 0 GARAGE = 3 7 6 . 0 BSMT=36 8 . 0 1ST FL F F E = 3 7 2 . 0 GARAGE = 3 7 0 . 0 BSMT=36 2 . 0 1ST FL FFE = 3 6 7 . 0 GARAGE=36 5 . 0 BSMT=357.0 1ST FL FFE=396.0 GARAGE=394.0 BSMT=386.0 W W W W W W W W W W W W -0+5 0 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+50 0+50 1+50 2+503+50 4+50 5+50 6+50 7+50 8+50 9+50 10+50 S SS S SS S S SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN SAN SAN S SAN SMH9SMH8 SMH7SMH6 SMH5 SMH4 SMH3 SMH2 SMH1 3 6 5 3 7 0 3 8 0 3 9 0 380 375 385 385 380 380 385 375 370 365 380 3 8 0 370 375 375 370 370 365 380 360370 365 360 3 7 0 3 6 5 36 0 355 38 0 375 365 355 355 3 7 5 3 8 5 3 9 0 3 9 5 395 4 0 5 4 1 0 390 390 390 385 3 9 5 4 0 0 395 395 390 D PROPOSED ROADWAY PROFILE SCALE: 1"=50' (HORIZONTAL); 1"=5' (VERTICAL) EN SW 50025 SCALE IN FEET 50 PROPOSED ROADWAY ALIGNMENT SCALE: 1"=50' DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : RO A D W A Y P L A N & P R O F I L E 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 RPP-1 11 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 1 _ R O A D W A Y P L A N & P R O F I L E . D W G T a b : 11 R O A D W A Y P L A N & P R O F I L E S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 5 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T SOIL EROSION & SEDIMENTATION CONTROL (SESC) PLAN: PROJECT DESCRIPTION 1.THE APPLICANT IS PROPOSING A 23-LOT RESIDENTIAL RESUBDIVISION LOCATED AT 47 SHARP HILL ROAD IN MONTVILLE. THE PARCEL WAS CREATED AS PART A SUBDIVISION APPROVED IN OCTOBER 2016. AS PART OF THE RESUBDIVISION, THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES (SANITARY SEWER, ELECTRIC, TELEPHONE, CABLE) WILL BE INSTALLED. THE RESIDENCES, DRIVEWAYS, INDIVIDUAL LOT GRADING, AND DRILLED WELLS SHOWN ON THE PLANS FOR THE NEW BUILDING LOTS ARE SHOWN FOR CONCEPTUAL PURPOSES ONLY. NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME. PRIOR TO ANY INDIVIDUAL LOT DEVELOPMENT, A SITE PLAN SHALL BE PREPARED IN CONFORMANCE WITH ALL APPLICABLE LOCAL REGULATIONS, AND REVIEWED AND APPROVED BY THE ZONING ENFORCEMENT OFFICER. THE DEVELOPMENT OF INDIVIDUAL LOTS SHALL NOT ADVERSELY AFFECT THE DEVELOPMENT OF NEWLY CREATED LOTS OR EXISTING ABUTTING PROPERTIES. 2.CONSTRUCTION IS ANTICIPATED TO COMMENCE IN FALL 2025. CONSTRUCTION WILL OCCUR IN TWO PHASES. PHASE ONE WILL INCLUDE THE CONSTRUCTION OF THE ROADWAY, ASSOCIATED ROADWAY DRAINAGE SYSTEM, STORMWATER MANAGEMENT IMPROVEMENTS, AND COMMON UTILITIES. PHASE ONE IS ANTICIPATED TO START FALL 2025 AND END BY FALL 2026 (~1 YEAR DURATION). PHASE TWO WILL INCLUDE THE CONSTRUCTION AND BUILD OUT OF EACH BUILDING LOT WITH A HOUSE WHICH WILL OCCUR AS EACH LOT IS SOLD. PHASE TWO IS ANTICIPATED START FALL 2026 AND END WINTER 2030 (~5 YEAR DURATION). IT SHOULD BE NOTED PHASE TWO IS NOT PART OF THE SCOPE OF THIS PROJECT AND NO LOT DEVELOPMENT IS PROPOSED AT THIS TIME (SEE NOTE #1 ABOVE). THE EXACT START AND END DATES OF PHASE TWO MAY VARY DUE TO VARIOUS FACTORS SUCH AS THE HOUSING MARKET, INTEREST RATES, ETC. 3.EXISTING TOPOGRAPHY ACROSS THE SITE IS MODERATE TO STEEP WITH ELEVATIONS RANGING FROM 416± ALONG THE WESTERN PROPERTY LINE, TO326 AT THE WETLAND IN THE SOUTHEAST CORNER. PER NRCS SOIL MAPPING, THE UNDERLYING SOIL ACROSS MOST OF THE SITE CONSISTS OF WOODBRIDGE FINE SANDY LOAM (HYDROLOGIC SOIL GROUP 'C/D'). RUNOFF FROM THE SITE EVENTUALLY FLOWS TO ROCKLAND POND LOCATED APPROXIMATELY 0.2 MILES EAST/NORTHEAST OF THE SITE 4.APPROXIMATELY 4.65± ACRES OF THE 19.5± ACRE PARCEL WILL BE DISTURBED BY EARTHWORK ACTIVITIES FOR THE CONSTRUCTION OF THE ROAD AND STORMWATER MANAGEMENT IMPROVEMENTS. THE PROJECT DEVELOPMENT WILL REQUIRE DEMOLITION, CLEARING AND EARTHWORK TO PREPARE THE SITE. EARTHWORK ACTIVITIES WILL EXPOSE SOILS TO EROSION DURING RAINFALL EVENTS 5.THE INTENT OF THIS SESC PLAN IS TO ESTABLISH STORMWATER MANAGEMENT CONTROLS DURING CONSTRUCTION TO PREVENT THE DISCHARGE OF SEDIMENT LADEN RUNOFF FROM ENTERING STORM DRAIN SYSTEMS OR ADJACENT PROPERTIES. 6.REFER TO INLAND WETLAND REPORT (UNDER SEPARATE COVER), STORMWATER MANAGEMENT REPORT (UNDER SEPARATE COVER), TEST HOLE LOGS (SHEET 16 OF 16), PERMEABILITY TEST RESULTS (SHEET 16 OF 16), AND STORMWATER MANAGEMENT IMPROVEMENTS AND DETAILS (SHEET 7 AND 16 OF 16). LOW-IMPACT DEVELPOMENT FEATURES INCLUDE MULTIPLE STORMWATER MANAGEMENT BASINS, AN INFILTRATION TRENCH FOR WATER, VEGETATED SWALES, AND DISCONNECTED IMPERVIOUS AREAS. GENERAL SESC REQUIREMENTS 1.THE SITE CONTRACTOR MUST FOLLOW ALL GUIDELINES SET FORTH IN THE MANUAL ENTITLED "CONNECTICUT GUIDELINES FOR SOIL EROSION & SEDIMENT CONTROL," EFFECTIVE DATE: MARCH 30, 2024, PUBLISHED BY THE COUNCIL ON SOIL AND WATER CONSERVATION IN COLLABORATION WITH CONNECTICUT DEPARTMENT OF ENERGY AND ENVIRONMENTAL PROTECTION. 2.SESC MEASURES INTENDED TO MINIMIZE SOIL EROSION AND TO CONTROL SEDIMENTATION DURING CONSTRUCTION INCLUDE: A.THE INSTALLATION OF SILT FENCE ALONG THE DOWNGRADIENT LIMIT OF DISTURBANCE. B.THE IMMEDIATE STABILIZATION OF DISTURBED AREAS THROUGH THE PLACEMENT OF TEMPORARY SEED AND MULCH OR FINAL TOPSOIL, SEED AND MULCH. C.CONSTRUCTION OF A TEMPORARY SEDIMENT TRAP. D.THE USE OF EROSION CONTROL BLANKETS TO STABILIZED CUT AND FILL SLOPES GRADED AT 3H:1V OR STEEPER. EROSION CONTROL BLANKET SHALL BE NORTH AMERICAN GREEN ROLLMAX BIONET C125BN AS MANUFACTURED BY NORTH AMERICAN GREEN, LOCATED AT 4609 E. BOONVILLE-NEW HARMONY ROAD, EVANSVILLE, INDIANA, 47725. E.DEVELOPMENT OF A CONSTRUCTION OPERATIONS PLAN IN CONSIDERATION OF BASIC CONSTRUCTION SEQUENCING OUTLINED HEREIN. 3.ALL ADJACENT PROPERTIES SHALL BE ADEQUATELY PROTECTED FROM SOIL EROSION AND SEDIMENTATION BOTHDURING AND AFTER CONSTRUCTION. 4.CONSTRUCTION ENTRANCE SHALL BE INSTALLED BEFORE CONSTRUCTION TRAFFIC INTO AND OUT OF THE SITE BEGINS. 5.THE CONTRACTOR SHALL INSTALL SILT FENCING PRIOR TO INITIATING CONSTRUCTION ACTIVITIES AND SHALL BE MAINTAINED/REPAIRED UNTIL FINAL STABILIZATION OF ALL DISTURBED AREAS. 6.ALL AREAS SHALL REMAIN UNDISTURBED UNTIL IMMEDIATELY PRIOR TO SITE DEVELOPMENT. 7.ALL EXISTING VEGETATION OUTSIDE OF THE LIMITS OF DISTURBANCE SHALL BE PROTECTED. EXISTING VEGETATION SHALL BE REMOVED ONLY IN AREAS NECESSARY FOR SITE CONSTRUCTION ACTIVITIES. 8.ALL CONSTRUCTION EQUIPMENT, MATERIALS AND STOCKPILES SHALL NOT BE PLACED OUTSIDE OF THE DISTURBED AREAS. 9.THE CONTRACTOR SHALL SEED AND MULCH DISTURBED AREAS EXPECTED TO REMAIN UNSTABILIZED FOR A PERIOD OF MORE THAN 30 DAYS. 10.THE CONTRACTOR SHALL COMPLETE PERMANENT SEEDING BETWEEN APRIL 1ST THROUGH JUNE 15TH AND AUGUST 15TH THROUGH OCTOBER 1ST. APPLY PERMANENT SOIL STABILIZATION MEASURES TO ALL GRADED AREAS WITHIN 7 DAYS OF ESTABLISHING FINAL GRADE AT A RATE OF 90 POUNDS PER 1,000 SQUARE FEET. RECOMMENDED SEED MIXTURE: FUTURA 2000 BY THE CHAS C. HART CO. CONTAINING THE FOLLOWING VARIETIES OF PERENNIAL RYEGRASSES: FIESTA II, BLAZER II, DASHER II AND EXPRESS. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION AND MAINTENANCE OF ALL SESC BEFORE, DURING AND AFTER CONSTRUCTION. THE CONTRACTOR IS ALSO RESPONSIBLE FOR THE PROPER REMOVAL AND DISPOSAL OF ALL EROSION AND SEDIMENT CONTROLS ONCE THE SITE IS COMPLETELY STABILIZED. 12.ALL SESC SHALL BE INSPECTED WEEKLY AND AFTER ALL RAINFALL EVENTS. ALL SESC SHALL BE REPAIRED OR REPLACED AS NECESSARY WITHIN 24 HOURS THROUGHOUT THE CONSTRUCTION DURATION. INSPECTION REPORTS SHALL BE SENT TO THE ROCKY HILL PLANNING & ZONING DEPARTMENT. CONSTRUCTION SEQUENCE - ROADWAY, DRAINAGE AND ASSOCIATED EARTHWORK (FALL 2025-FALL 2026) 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (~5 DAYS). 2.ENSURE ALL LAND USE PERMITS HAVE BEEN SECURED. OBTAIN ALL NECESSARY PERMITS (~30 DAYS). 3.INSTALL TEMPORARY CONSTRUCTION ENTRANCE AND SEDIMENT FENCE AS SHOWN ON THE SESC PLAN (~10 DAYS). 4.CONSTRUCT TEMPORARY SEDIMENT TRAP (~10 DAYS). 5.REMOVE ALL TREES, BRUSH AND STUMPS WITHIN LIMIT OF DISTURBANCE AS NECESSARY. THERE SHALL BE NO BURIAL OF CONSTRUCTION DEBRIS, STUMPS, BRUSH OR UNSUITABLE MATERIAL ON SITE (~45 DAYS). 6.REMOVE AND STOCKPILE ALL TOPSOIL ON SITE AND PROVIDE A SEDIMENT FENCE ON THE DOWNSLOPE SIDE. SEED STOCKPILE WITH PERENNIAL RYEGRASS AT A RATE OF 40 POUNDS PER ACRE AND MULCH WITH HAY OR STRAW. IF OUTSIDE THESE GROWING SEASON, AREAS SHALL BE STABILIZED WITH STRAW OR HAY MULCHING AT A RATE OF 90 POUNDS PER 1,000 SQUARE FEET (~10 DAYS). 7.EXCAVATE AND/OR FILL WORK SITE TO SUBGRADE LEVEL (~45 DAYS). A.NO ROCK CRUSHING AND/OR BLASTING IS PROPOSED. IF BLASTING IS REQUIRED FOR ROCK REMOVAL, A PRE-BLAST SURVEY SHALL BE PERFORMED. IF BLASTING AND ROCK CRUSHING ARE REQUIRED THEN APPROVAL OF THE PLANNING & ZONING COMMISSION MAY BE REQUIRED. B.FILL WILL BE PLACED AND COMPACTED IN 8 INCH LIFTS AND SHALL BE FREE OF BRUSH, RUBBISH, LOGS, BUILDING DEBRIS, OR ANY OTHER OBJECTIONABLE MATERIAL. CONSTRUCT RETAINING WALLS AS REQUIRED. C.MOISTEN SOIL SURFACE PERIODICALLY WITH WATER TO MINIMIZE DUST. 8.INSTALL STORMWATER MANAGEMENT IMPROVEMENTS AND DRAINAGE STRUCTURES STARTING FROM THE MOST DOWNGRADIENT IMPROVEMENTS. INSTALL FILTER FABRIC AND/OR HAY BALES AT CATCH BASINS IMMEDIATELY AFTER CATCH BASIN INSTALLATION (~ 60 DAYS). 9.INSTALL SANITARY SEWER LINES & STRUCTURES, TRANSFORMERS, AND ELECTRICAL, TELEPHONE, CABLE CONDUITS (~60 DAYS). 10.PLACE AND COMPACT BASE MATERIAL TO FINAL GRADE. INSTALL PAVEMENT BASE COURSE, CURB, ETC (~30 DAYS). 11.ALL DISTURBED AREAS NOT COVERED BY PAVEMENT, ETC., SHALL BE GRADED AND STABILIZED (~10 DAYS) AS FOLLOWS: A.PLACE MINIMUM 4 INCHES OF TOPSOIL IN ALL AREAS. B.APPLY RECOMMENDED SEED MIXTURE AT RECOMMENDED RATE. C.APPLY STRAW OR HAY MULCH ON ALL SEEDED AREAS. ALL GRADED AREAS WITH SLOPES GRADED AT 3H:1V OR STEEPER SHALL BE STABILIZED WITH EROSION CONTROL BLANKETS 12.INSTALL FINAL PAVEMENT COURSE (~10 DAYS). 13.FINAL GRADE AND PLACE TOPSOIL SEED AND MULCH (~30 DAYS). 14.WHEN ALL GRADED AREAS ARE PERMANENTLY STABILIZED, REMOVE ALL EROSION AND SEDIMENT CONTROLS. REMOVE TRAPPED SEDIMENT(S) (~10 DAYS). CONSTRUCTION SEQUENCE - INDIVIDUAL LOTS (TIMING OF CONSTRUCTION TBD) THE CONSTRUCTION OF INDIVIDUAL BUILDINGS WILL BE COMPLETED AS LOTS ARE SOLD. DURING THE CONSTRUCTION OF EACH BUILDING, THE CONTRACTOR SHALL FOLLOW THE FOLLOWING SESC INSTALLATION PROCEDURES: 1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY. 2.ENSURE ALL LAND USE PERMITS HAVE BEEN SECURED. OBTAIN ALL NECESSARY PERMITS. 3.INSTALL SEDIMENT FENCE ON THE DOWNGRADIENT EDGE OF PROPOSED DISTURBANCE. 4.REMOVE AND STOCKPILE TOPSOIL ON SITE AND PROVIDE A SEDIMENT FENCE ON THE DOWNSLOPE SIDE. SEED STOCKPILE WITH PERENNIAL RYEGRASS AT A RATE OF 40 POUNDS PER ACRE AND MULCH WITH HAY OR STRAW. IF OUTSIDE THESE GROWING SEASON, AREAS SHALL BE STABILIZED WITH STRAW OR HAY MULCHING AT A RATE OF 90 POUNDS PER 1,000 SQUARE FEET. 5.BEGIN CONSTRUCTION OF BUILDING AND INSTALL UTILITIES. ADD EROSION CONTROL DEVICES AS NEEDED. 6.PLACE AND COMPACT BASE MATERIAL TO FINAL GRADE. INSTALL PAVEMENT BASE COURSE, CURB, SIDEWALKS, STEPS, ETC. 7.ALL DISTURBED AREAS NOT COVERED BY BUILDINGS, PARKING, SIDEWALKS, ETC., SHALL BE GRADED AND STABILIZED AS FOLLOWS: A.PLACE MINIMUM 4 INCHES OF TOPSOIL IN ALL AREAS. B.APPLY RECOMMENDED SEED MIXTURE AT RECOMMENDED RATE. C.APPLY STRAW OR HAY MULCH ON ALL SEEDED AREAS. ALL GRADED AREAS WITH SLOPES GRADED AT 3H:1V OR STEEPER SHALL BE STABILIZED WITH EROSION CONTROL BLANKETS 9.INSTALL FINAL PAVEMENT COURSE. 10.FINAL GRADE AND PLACE TOPSOIL SEED AND MULCH. 11.WHEN ALL GRADED AREAS ARE PERMANENTLY STABILIZED, REMOVE ALL EROSION AND SEDIMENT CONTROLS. REMOVE TRAPPED SEDIMENT(S). DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : SO I L E R O S I O N & S E D I M E N T C O N T R O L NA R R A T I V E A N D D E T A I L S 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 SEN-1 12 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 2 - 1 6 _ S I T E D E T A I L S . D W G T a b : SE S C D E T A I L S S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T NOTE: ALL ANTI-TRACKING PADS SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH 2002 CT GUIDELINES FOR SOIL EROSION & SEDIMENT CONTROL, AS AMENDED. REFERENCE: 2002 CT GUIDELINES FOR EROSION AND SEDIMENT CONTROL, DEEP BULLETIN 34, FIGURE CE-2. ERRATA DATA 3/17/06, PAGE 5-12-4 (4" STONE NOW 6" STONE). ANTI-TRACKING PAD DETAIL NOT TO SCALE PLAN LONGITUDINAL SECTION 12' WIDE (MIN.) ACCESS ROAD TO WORK AREA 5' RADIUS (MIN.) PAVED EXISTING ROAD STRIP GROUND LINE (REMOVE TOPSOIL AND ORGANICS PRIOR TO CRUSHED STONE PLACEMENT) INSTALL MINIMUM 12" SUBBASE OF FREE DRAINING MATERIAL OR ROAD STABILIZATION GEOTEXTILE AS NECESSARY ON UNSTABLE SOILS FILTER FABRIC IF NECESSARY EXISTING PAVED ROAD 6" MIN. DEPTH CT-DOT NO. 3 STONE OR ASTM C-33 NO. 33 50' (MIN.)ACCESS 1 3B 3A 5 NOTES: 1.PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. WHEN USING CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2.BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP x 6" (15cm), WIDE TRENCH WITH APPROXIMATELY 12" (30CM) OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm), PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 cm) MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. 3.ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM TM, STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4.THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5czm-12.5cm), OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED SEAM STITCH TM ON THE PREVIOUSLY INSTALLED BLANKET. 5.CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5cm) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30cm), APART ACROSS ENTIRE BLANKET WIDTH. 4 2 EROSION CONTROL BLANKET DETAIL NOT TO SCALE 2"-5" (5cm - 12.5cm) 12" (30cm) 6" (1 5 c m ) 6" (15cm) NORTH AMERICAN GREEN BIONET BIODEGRADABLE EROSION CONTROL BLANKET 3" (7.5cm) FINISHED GRADING, TOPSOIL & SEEDING NOTES: 1.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE CORRECT SIZE DEVICE FOR EACH INLET. FOR NON-STANDARD CATCH BASINS AND INLETS, THE CONTRACTOR SHALL MEASURE DIMENSIONS IN THE FIELD AND ORDER THE APPROPRIATE SIZE(S). 2.THE INLET SEDIMENT CONTROL DEVICE SHALL BE OF HIGH FLOW DESIGN (200 GAL/MIN/FT), AS PER THE MANUFACTURER'S SPECS. 3.THE SEDIMENT CONTROL DEVICE SHALL BE INSPECTED DAILY BY THE CONTRACTOR AND CLEANED AND MAINTAINED A MINIMUM ONCE PER MONTH OR WITHIN THE 48 HOURS FOLLOWING A STORM EVENT. THE FILTER SHALL BE REPLACED OR CLEANED WHEN THE BAG BECOMES HALF FULL. THE FILTER SHALL BE CLEANED IN A MANNER WHICH ENSURES THAT ALL SEDIMENT REMAINS ON SITE. 4.SUBSTITUTION OF A SHEET OF FILTER FABRIC PLACED OVER THE OPENING OF THE INLET IS NOT APPROVED. 5.RECESSED CURB INLET CATCH BASINS MUST BE BLOCKED WHEN USING FILTER FABRIC INLET SACKS, SIZE OF FILTER INLET SACK TO BE DETERMINED BY MANUFACTURER. 6.THE FILTER DEVICE SHALL BE MANUFACTURED BY ACF ENVIRONMENTAL OR APPROVED EQUAL. DUMP LOOPS SEDIMENTCONTROL BAG "SILT SACK" OR EQUAL 1" REBAR FOR BAG REMOVAL FROM INLET LEN G T H WIDTH DE P T H BAG DETAIL INSTALLATION DETAIL SECTION PERSPECTIVE VIEW EXPANSION RESTRAINT (1/4" NYLON ROPE, 2" FLAT WASHERS) DUMP LOOP 2 EACH DUMP STRAPS EXPANSION RESTRAINT (1/4" NYLON ROPE, 2" FLAT WASHERS) BAG DEPTH TO TOP OF PIPE CATCH BASIN FILTER (SILT SACK) DETAIL NOT TO SCALE NOTES: 1.PERVIOUS STONE DIKE SHALLB E CONSTRUCTED OF CT DOT MODIFIED RIPRAP WITH #3STONE ON FACE. 2.NON-OVERFLOW PORTIONS OF ABUTMENTS OF TEMPORARY SEDIMENT TRAPS MAY BE CONSTRUCTED OF COMPACTED EARTHFILL. 3.TEMPORARY SEDIMENT TRAP SHALL BE SIZED BASED ON A MINIMUM OF 134 CUBIC YARDS OF WATER STORAGE PER ACRE DRAINED, A MINIMUM WET STORAGE VOLUME EQUAL TO HALF OF THE TOTAL STORAGE VOLUME AND A MINIMUM DRY STORAGE VOLUME EQUAL TO HALF OFTHE TOTAL STORAGE VOLUME. PERVIOUS STONE DIKE (SEE NOTES 1 & 2) TOP WIDTH VS. HEIGHT H = HEIGHT OF EMBANKMENT W = MIN. TOP WIDTH OF EMBANKMENT H (ft) W (ft) 1.5 2.0 2.0 2.0 2.5 2.5 3.0 2.5 3.5 3.0 4.0 3.0 4.5 4.0 5.0 4.5 1 2 ORFLATTER FLOW WET POOL ELEV. 1 1.52 1 WET POOL ELEV. 2 MIN. W TOP WIDTH HEIGHT (5.0' MAX.) 1.0' MIN. 1.0'WEIR LENGTH 1.0' MIN. DRY STORAGE 3.0' MAX. HEIGHT (5.0' MAX.) 1.0' MIN. ELEVATION MARK FOR CLEANOUT CT DOT #3 STONE WEIR CREST GEOTEXTILE FABRIC GEOTEXTILE FABRIC SPILLWAY DETAIL SUMMARY OF TEMPORARY SEDIMENT TRAP SIZING CALCULATIONS ITEM TEMPORARY SEDIMENT TRAP 'A' DRAINAGE AREA (ACRES)4.55± TOTAL STORAGE VOLUME REQUIRED (CF)16,462 WET STORAGE VOLUME REQUIRED (CF)8,231 DRY STORAGE VOLUME REQUIRED (CF)8,231 TEMPORARY SEDIMENT TRAP DETAIL NOT TO SCALE TYPICAL CROSS-SECTION 1 2 ORFLATTER 1 SESC PLAN (CONTINUED): TRENCH EXCAVATION AND BACKFILL 1.THE CONTRACTOR SHALL PROPERLY MAINTAIN ALL BACKFILLED EXCAVATIONS. ANY DEPRESSIONS DUE TO SETTLING IN THESE AREAS SHALL BE FILLED AND RESEEDED AS NECESSARY. 2.THE WIDTH OF ALL EXCAVATED TRENCHES SHALL BE KEPT AS NARROW AS PRACTICABLE TO ACCOMMODATE THE WORK. ALL MATERIALS EXCAVATED FROM TRENCHES SHALL BE STOCKPILED AND USED AS TRENCH BACKFILL MATERIAL UNLESS IT IS DETERMINED TO BE UNSUITABLE BY THE ENGINEER. EXCESS MATERIALS SHALL BE PROPERLY DISPOSED OF BY THE CONTRACTOR. VEGETATIVE TURF ESTABLISHMENT PROCEDURE 1.SCARIFY ALL AREAS TO BE TOPSOILED AND SEEDED. APPLY A MINIMUM OF 4 INCHES OF TOPSOIL ON ALL AREAS TO BE SEEDED. APPLY GRASS SEED, LIME, FERTILIZER AND MULCH ACCORDING TO THE FOLLOWING SCHEDULE: 2.PERMANENT SEED MIXTURE: CREEPING RED FESCUE 0.45 LBS. PER 1,000 SQ. FT. REDTOP 0.05 TALL FESCUE 0.45 TOTAL 0.95 3.FERTILIZER: 10-10-10 APPLY AT 7.5 LBS. PER 1,000 SQ. FT. 4.LIMESTONE: APPLY AT 150 LBS. PER 1,000 SQ. FT. 5.MULCHING: SPREAD HAY OR STRAW OVER ALL AREAS AFTER SEEDING. USE 1 1/2 TO 2 BALES PER 1,000 SQ. FT. TARGET FOR 100% COVERAGE. ANCHOR BY USING NETTING OR TRACKING AS NECESSARY. 6.TEMPORARY EROSION CONTROL BLANKETS: USE TEMPORARY EROSION CONTROL BLANKETS ON ALL SEEDED SLOPES GRADED AT 3H:1V OR STEEPER AND/OR AS DIRECTED BY THE DESIGN ENGINEER. 7.SEEDING DATES: SEEDING DATES IN CONNECTICUT ARE NORMALLY APRIL 1 THROUGH JUNE 15 AND AUGUST 15 THROUGH OCTOBER 1. SEED GERMINATION NORMALLY CANNOT BE EXPECTED FROM NOVEMBER THROUGH FEBRUARY. IF ADEQUATE SEED GERMINATION IS NOT POSSIBLE DUE TO TIME OF YEAR CONSTRAINTS, MULCHING SHALL BE ADEQUATELY PROVIDED TO PROTECT THE SEED FROM WIND AND SURFACE EROSION UNTIL THE WEATHER IMPROVES AND THE SEEDING BECOMES WELL ESTABLISHED. MAINTENANCE OF EROSION CONTROL DEVICES: HAYBALE BARRIERS/GEOTEXTILE SILT FENCES: 1.INSPECT HAY BALE BARRIERS/GEOTEXTILE SILT FENCE AT LEAST ONCE A WEEK AND WITHIN 24 HOURS AFTER THE END OF A STORM WITH A RAINFALL AMOUNT OF 1/2" OR GREATER TO DETERMINE MAINTENANCE NEEDS. 2.REMOVE SEDIMENT DEPOSITS OR INSTALL A SECONDARY BARRIER/FENCE WHEN SEDIMENT DEPOSITS REACH APPROXIMATELY ONE HALF HEIGHT OF THE BARRIER/FENCE. 3.REPLACE OR REPAIR THE BARRIER/FENCE WITHIN 24 HOURS OF OBSERVED FAILURE. IF REPETITIVE FAILURE OCCURS, CONSULT 2002 GUIDELINES FOR TROUBLESHOOTING FAILURES. 4.MAINTAIN THE HAY BALE BARRIER/SILT FENCE UNTIL THE CONTRIBUTING AREA IS STABILIZED. 5.AFTER UPSLOPE AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE STAKES FROM HAY BALES; PULL UP FENCE SUPPORT POSTS AND CUT OFF GEOTEXTILE AT GROUND. UNLESS OTHERWISE REQUIRED, HAY BALES MAY BE LEFT IN PLACE OR BROKEN UP FOR GROUND COVER. IF ACCUMULATED SEDIMENT EXCEEDS 6 INCHES, RE-GRADE OR REMOVE SEDIMENT. STABILIZE ANY DISTURBED SOILS. CONSTRUCTION ENTRANCES AND ROADWAYS: 1.MAINTAIN THE ENTRANCE IN A CONDITION WHICH WILL PREVENT TRACKING AND WASHING OF SEDIMENTS ONTO PAVED SURFACES. 2.PROVIDE PERIODIC TOP DRESSING AND ADDITIONAL STONE OR LENGTH AS NECESSARY. 3.IMMEDIATELY REMOVE ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PAVED SURFACES. ROADS ADJACENT TO THE CONSTRUCTION SITE SHALL BE LEFT CLEAN EVERY DAY. TEMPORARY SEDIMENT TRAP: 1.INSPECTIONS SHALL BE AT SAME INTERVALS AS THE HAYBALE BARRIER/SILT FENCE INSPECTION SCHEDULE. 2.OUTLET SHALL BE CHECKED FOR INTEGRITY; HEIGHT OF THE STONE OUTLET SHALL BE MAINTAINED AT ONE FOOT BELOW CREST OF EMBANKMENT. SEDIMENT ACCUMULATION AND FILTRATION PERFORMANCE SHOULD BE OBSERVED. 3.WHEN SEDIMENTS HAVE ACCUMULATED TO ONE HALF OF THE MINIMUM REQUIRED STORAGE VOLUME, DE-WATER BASIN, REMOVE SEDIMENTS, RESTORE TRAP TO ORIGINAL DIMENSIONS AND DISPOSE OF SEDIMENT AT A LOCATION AND MANNER THAT WILL NOT RESULT IN EROSION OR SEDIMENTATION. 4.AFTER CONTRIBUTING AREA IS STABILIZED, REMOVE BASIN, AND RE-GRADE AND STABILIZE AREA. TEMPORARY CHECK DAMS: 1.INSPECT CHECK DAMS AT LEAST ONCE A WEEK AND WITHIN 24 HOURS AFTER THE END OF A STORM WITH A RAINFALL AMOUNT OF 1/2" OR GREATER TO DETERMINE MAINTENANCE NEEDS. 2.REMOVE THE SEDIMENT DEPOSITS WHEN DEPOSITS REACH APPROXIMATELY HALF THE HEIGHT OF THECHECK DAM. 3.REPLACE OR REPAIR THE CHECK DAM WITHIN 24 HOURS OF OBSERVED FAILURE. FAILURE OF THE CHECK DAM HAS OCCURRED WHEN SEDIMENT FAILS TO BE RETAINED BECAUSE ONE OR MORE OF THE FOLLOWING: ·STONE OR FIBER ROLLS HAVE MOVED ·SOIL HAS ERODED AROUND OR UNDER THE CHECK DAM REDUCING ITS FUNCTIONAL CAPACITY ·TRAPPED SEDIMENTS ARE OVERTOPPING THE CHECK DAM 4.WHEN REPETITIVE FAILURES OCCUR AT THE SAME LOCATION, REVIEW CONDITIONS AND LIMITATIONS FOR USE AND DETERMINE IF ADDITIONAL CONTROLS (E.G., TEMPORARY STABILIZATION OF CONTRIBUTING AREA, DIVERSIONS, CHECK DAMS) ARE NEEDED TO REDUCE FAILURE RATE. 5.MAINTAIN THE CHECK DAM UNTIL THE CONTRIBUTING AREA IS STABILIZED. 6.AFTER THE CONTRIBUTING AREA IS STABILIZED, REMOVE ACCUMULATED SEDIMENT AND REMOVAL ALL STONE. STABILIZE (SEED AND MULCH) ANY DISTURBED SOIL THAT REMAINS FROM CHECK DAM REMOVAL OPERATIONS IMMEDIATELY FOLLOWING THEIR REMOVAL. TEMPORARY DIVERSION DITCHES/SWALES: 1.WHEN THE TEMPORARY DIVERSION IS LOCATED IN CLOSE PROXIMITY TO ONGOING CONSTRUCTION ACTIVITIES, INSPECT AT THE END OF EACH DAY AND IMMEDIATELY REPAIR DAMAGES. OTHERWISE, INSPECT ON SAME INTERVAL AS THE TEMPORARY SEDIMENT TRAP. 2.REPAIR THE DIVERSION WITHIN 24 HOURS OF ANY OBSERVED FAILURE. FAILURE HAS OCCURRED WHEN THE DIVERSION HAS BEEN DAMAGED SUCH THAT IT NO LONGER MEETS THE SPECIFICATIONS IN THE 2002 GUIDELINES. 3.IF REPETITIVE FAILURES OCCUR, REVIEW CONDITIONS AND DETERMINE IF ADDITIONAL MEASURES OR AN ALTERNATIVE MEASURE IS NECESSARY. X-SECTION (THROUGH CHANNEL) X-SECTION (SPACING BETWEEN CHECK DAMS) PLAN TEMPORARY CHECK DAM DETAIL NOT TO SCALE COUPLING OF ADJACENT STAKES INSTALLATION NOTES FOR SILT FENCE/HAYBALES: 1.PLACE HAY BALES ON CONTOUR AND WITH LAST HAY BALES UPSLOPE TO THAT TOP OF LAST SEVERAL HAY BALES ARE HIGHER THAN LINE OF HAY BALES. 2.EXCAVATE TRENCH 4" MIN. AND PLACE FILL UPSLOPE OF TRENCH 3.PLACE HAY BALE AND STAKE FIRST STAKE AT ANGLE TOWARDS FIRST BAKE. STAKES ARE 18" MIN. INTO GROUND. 4.WEDGE LOOSE HAY BETWEEN BALES. 5.BACKFILL & COMPACT EXCAVATED FILL ALONG UPHILL SIDE OF HAY BALE. FINISH GRADE FLOW HAYBALES WITH 2-2"x2"x36" WOOD STAKES COMPACTED BACKFILL 12 " MANUFACTURER'S COUPLER OR BIND WITH WIRE SECTION 'A' STAKE 'A' STAKE 'B' SECTION 'B' SECTION 'B' STAKE 'B' SECTION 'A' STAKE 'B' TYPICAL HAYBALE BACKED SEDIMENT FENCE DETAIL NOT TO SCALE SILT FENCE W/ 2"x2"x36" WOOD POST 6" CURB ROLLED HIGH TENSILE STEEL WITH 3/8" DIAMETER HOLES SPACED 1" ON CENTER NOTES: 1.SIGN MUST BE INSTALLED PERPENDICULAR TO TRAVEL LANE. 2.SIGNS INSTALLATIONS WITHIN THE STATE OF CONNECTICUT RIGHT OF WAY SHALL INCLUDE BREAKAWAY MOUNTING 3.ALL SIGNS WITHIN THE CITY R.O.W. ARE TO BE HIGH INTENSITY PRISMATIC, INSTALLED WITH BREAKAWAY POSTS AND IN ACCORDANCE WITH THE M.U.T.C.D. 4.SIGN MATERIALS SHALL BE IN ACCORDANCE WITH SECTION M.18 OF THE CONNDOT STANDARD SPECIFICATIONS FOR ROADWAY, BRIDGES AND INCIDENTAL CONSTRUCTION. GREEN BAKED ENAMEL FLANGED CHANNEL POST NEW ENGINEER GRADE .080 ALUMINUM SIGN GREEN BAKED ENAMEL FLANGED CHANNEL POST BACKFILL CONCRETE BASE (12" SQ) SIGN PER PLAN DIRECTIONAL SIGN 1-1/2 SF MAX REFLECTIVE LETTERING 3-1/8" 1-1/4" 1- 1 7 / 3 2 " OUTERMOST EDGE OF SIGN MAY NOT PROTRUCE PAST THE BACK FACE OF CURB PAVEMENT MOUNT SIGN WITH TAMPER PROOFHARDWARE 36" MAX. 60 " 18 " 12 " 6" GRADE A A SECTION A-A STOP SIGN TRAFFIC SIGN NOT TO SCALE STOP SIGN:R1-1; 31-0552-30" STOP SECTION COMPACTED SUBGRADE OR UNDISTURBED MATERIAL 1-1/2" WEARING COURSE, CLASS 2 2-1/2" BINDER COURSE, CLASS 1 4" PROCESSED AGGREGATE BASE (M.05.01) 8" GRAVEL SUBBASE (M.02.06 GRADATION 'A') 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : SI T E D E T A I L S 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 DT-1 13 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 2 - 1 6 _ S I T E D E T A I L S . D W G T a b : SI T E D E T A I L S S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M BITUMINOUS CONCRETE LIP CURBING NOT TO SCALE 6"5" 48 ° 3"± 9" PAVEMENT BINDER COARSE 21° R=2" FINISHED GRADE TACK COAT 6" HIGH MACHINE FORMED CLASS 3 BITUMINOUS CONCRETE LIP CURB (BCLC) WHERE INDICATED ON THE SITE PLAN 2" COMPACTED THICKNESS BITUMINOUS CONCRETE PAVEMENT (CLASS 2) 8" BANK RUN GRAVEL ADEQUATELY COMPACTED (NON-ORGANIC) EARTH SUBGRADE BITUMINOUS CONCRETE PAVEMENT SECTION (DRIVEWAY) NOT TO SCALE BITUMINOUS CONCRETE PAVEMENT SECTION (ROADWAY) NOT TO SCALE TOWN OF MONTVILLE RESIDENTIAL DRIVEWAY X-SECTION NOT TO SCALE SAG CURVE IN DRIVEWAY CREST CURVE IN DRIVEWAY 1/4" PER FT. 1/4" PER FT. NOTES: 1.ANY FIELD CUTTING, DRILLING, OR MACHINING OF POST AND RAILS SHALL BE RETREATED WITH 2 BRUSH COATS OF COPPER NAPTHENATE. 2.RAILS AND POST SHALL BE SOUTHERN YELLOW PINE, GRADE NO. 2 DENSE TREATED WITH C.C.A. (AWPA STANDARD P5) WITH A MINIMUM RETENTION OF 0.6 POUNDS PER CUBIC FEET (P.C.F.) TIMBER SHALL BE KILN DRIED AFTER TREATMENT (KDAT) TO < 19% M.C. 3.BACKFILL IN ALL CASES SHALL BE MADE WITH MATERIAL CAPABLE OF BEING COMPACTED. 4.ALL POSTS SHALL BE ERECTED TO THE LINES AND GRADES INDICATED IN THE DRAWINGS THE TOP INSIDE EDGES OF ALL POSTS SHALL BE WITHIN 1/4 INCH OF THEIR CORRECT POSITION. 5.ALL SURFACES WHERE THE PRESERVATIVE ENVELOPE IS INTERRUPTED SHALL RECEIVE TWO BRUSH COATS OF COPPER NAPTHENATE. 6.CRUSHED TRAPROCK SHALL BE PLACED ALONG THE ENTIRE LENGTH OF THE FENCE. 8" 8x8 POST MORTISE 3x8 RAIL 8" SECTION OF MORTISE & TENON 1" CHAMFER 3x8 WOOD RAIL 8x8 POST TOP VIEW OF POST 8'-0" O.C. 8" 12 " MI N , . 5'- 0 " 2'- 8 " 2" CRUSHED TRAPROCK COMPACTED BACKFILL SUBGRADE SECTION OF TIMBER RAIL 1" CHAMFER 8x8 POST 3x8 WOOD RAIL 6" 2' - 4 " 3" 12 " M I N . PRESSURE TREATED SOUTHERN YELLOW PINE 2" CRUSHED TRAPROCK (3" DEPTH) LANDSCAPE FABRIC COMPACTED BACKFIL SUBGRADE SECTION OF POST TIMBER POST AND RAIL NOT TO SCALE 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T 4" DIA. SMOOTHWALL HDPE AS REQUIRED INJECTION MOLDED ST 90° BEND INSERT INJECTION MOLDED, GASKETED SPIGOT BY BELL REDUCER CAST IRON DOWNSPOUT ADAPTER NOTES: 1.CATCH BASIN TOPS, CURBS AND GRATE COMPONENTS SHALL CONFORM TO CTDOT FORM 817 STANDARD SPECIFICATION FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION AND CTDOT HIGHWAY STANDARD SHEETS HW-507_07 AND HW-507_08, AS AMENDED. 3.REINFORCING STEEL DEFORMED BARS ARE NOT SHOWN AND SHALL CONFORM TO LATEST CTDOT STANDARDS & SUPPLEMENTALS AND ASTM SPECIFICATION A615, GRADE 60, MINIMUM COVER 2" UNLESS OTHERWISE NOTED. 4.ALL STEEL, EXCEPT REINFORCING BARS, SHALL BE GALVANIZED IN CONFORMANCE WITH SECTION M06.03 OF CONNECTICUT STANDARD SPECIFICATIONS. 5.TYPE "C" CATCH BASIN DEPRESSED GUTTER STRIPS SHALL CONFORM TO CTDOT STANDARD SHEET HW-507_01, AS AMENDED. REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW_507_04, HW-507_07 & HW-507_08, CT DOT FORM 817, AND UNITED CONCRETE PRODUCTS, AUGUST 2015. 3'-10 3/8"3'-8 1/2" 3'- 1 0 3 / 8 " 3'- 8 1 / 2 " 4'- 8 3/4"4'-9 1/4" 4'- 8 3/4"4'-9 1/4" A B A B NORMAL GUTTER LINE NOTES: 1.TRAP HOODS SHALL BE CAST IRON FOR 10", 12", 15" AND 18 PIPE SIZES AND FABRICATED ALUMINUM FOR 21" OR GREATER. 2.ALL TRAP HOODS SHALL INCLUDE STAINLESS STEEL HOOKS OR HANGERS FOR MOUNTING TO THE CATCH BASIN WALL. BACK PLATES SHALL BE FURNISHED ONLY WHEN REQUESTED. 3.TRAP HOODS SHALL BE FROM CAMPBELL FOUNDRY. NEENAH FOUNDRY, EAST JORDAN IRON WORKS OR APPROVED EQUAL. DIMENSIONS AND MODEL NUMBERS VARY BASED ON DISCHARGE PIPE SIZE AND MANUFACTURER. 4.SEE MANUFACTURER FOR INSTALLATION INSTRUCTIONS. TYPE "C" AND "CL" CATCH BASIN TOP DETAILS NOT TO SCALE 4'-0" LENGTH (TYP) 2" DEPRESSION IN SEDIMENTATION BOTTOM OF BASIN CATCH BASIN TRAP HOOD DETAIL NOT TO SCALE PLAN TYPE "CL" TOP SECTION A-TYPE "CL" SECTION B-TYPE "CL"SECTION B-TYPE "C" SECTION A-TYPE "C" PLAN TYPE "C" TOP TRAP HOOD MINIMUM DIMENSIONS PIPE SIZE A B C 10"12"20"6-1/2" 12"16"22"7-1/2" 15"19"25"9" 18"22"28"10" A C B PIPE S I Z E OU T S I D E D I A . O.D. OF HOOD +1" SECTIONS BACK PLATE PIPE (SIZE AND TYPE VARIES) CATCH BASIN WALL TRAP HOOD TRAP HOOK SLOT TO SUIT TRAP HOOK OR HANGER INJECTION MODED ST 45° WYE 4" DIA. SMOOTH WALL HDPE AS REQUIRED INJECTION MOLDED ST 45° BEND CLEANOUT SLEEVE 8" FINISHED GRADE CAST IRON TOP 10" SQ DOWNSPOUT 4" DIA. SMOOTH WALL HDPE AS REQUIRED INJECTION MODED ST 45° WYE NYOPLAST CLEAN OUT END CAP FINISHED GRADE CLEAN OUT TELL-TALE MARKER 8"x8" LUESTONE OR CMU DOWNSPOUT BUILDING FACE DOWNSPOUT ADAPTER ROOF DRAIN MANIFOLD PER PLAN INJECTION MOLDED WT TEE FITTING ROOF DRAIN DOWNSPOUT CONNECTION NOT TO SCALE DRAINAGE MANHOLE OR CATCH BASIN TRAP HOOD DEBRIS & OILS ON SURFACE DRAINAGE OUTLET PIPE DOWNSPOUT CONNECTIONAND CLEANOUT FOR SIDEWALK AND PATIOS DOWNSPOUT CONNECTIONAND CLEANOUT FOR LAWN AND LANDSCAPE AREAS 2'-7" DIA.5"5" 2-5" DIA. 2'-3 12" DIA. 1'-11" DIA. 3" 34" 8" A A' 15° 2'-1 12" DIA. 2'-1" DIA. 34" RAISED LETTERS AS REQUIRED BY STATE, LOCAL OR FEDERAL STANDARDS NOTES: 1.STORM MANHOLE FRAMES AND COVERS SHALL CONFORM TO CTDOT FORM 817 STANDARD SPECIFICATION FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION AND CT DOT HIGHWAY STANDARD SHEETS HW-507_10, AS AMENDED. 2.CHANNELS MAY BE SHAPED IN CONCRETE BASE OF MANHOLD ORFORMED USING BRICK OR MASONRY, UNLESS OTHERWISE DIRECTED. 3.A FRAME OF 3'-3" WITH 4" FLANGE SHALL BE USED WHEN THE TOP DIAMETER OF A PRECAST CONE IS LESS THAN 3'-6". ALL OTHER FRAME DIMENSIONS SHALL REMAIN THE SAME. 4.ALL DIMENSIONS SUBJECT TO MANUFACTURING TOLERANCES. REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW-507_04 & HW-507_10, CT DOT FORM 817. STORM PICK HOLE NON-SKID LUGS 1 12"∅BONDING HOLES, 8 EA. 1 12" ∅ HANDLING HOLES, 2REQUIRED STORM MANHOLE FRAME & COVER DETAIL NOT TO SCALE PLAN SECTION A-A' NOTES: 1.PRECAST CONCRETE CATCH BASIN COMPONENTS SHALL CONFORM TO CTDOT FORM 817 STANDARD SPECIFICATION FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION AND CTDOT HIGHWAY STANDARD SHEETS HW-507_04, HW-507_07 & HW-507_08, AS AMENDED. 2.THIS DETAIL IS BASED ON CTDOT PRECAST CONCRETE TYPE "C" & "CL" CATCH BASIN COMPONENTS, (UNDER 10' DEEP SHOWN). 3.REINFORCING STEEL DEFORMED BARS ARE NOT SHOWN AND SHALL CONFORM TO LATEST CTDOT STANDARDS & SUPPLEMENTALS AND ASTM SPECIFICATION A615, GRADE 60, MINIMUM COVER 2" UNLESS OTHERWISE NOTED. 4.METHOD OF MANUFACTURE SHALL BE WET CAST. 5.SUMP SECTION SHALL BE MONOLITHIC. 6.DESIGN LOAD SHALL BE AASHTO H-20. REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW_507_04, HW-507_07 & HW-507_08, CT DOT FORM 817, AND UNITED CONCRETE PRODUCTS, AUGUST 2015 A B TYPE "C" AND "CL" PRECAST CONCRETE CATCH BASIN DETAILS NOT TO SCALE PLAN TYPICAL JOINT BELOW PIPE INVERT TYPICAL JOINT ABOVE PIPE INVERT SECTION BSECTION A 4'-4" FOR LESS THAN 10' DEEP 5'-0" FOR GREATER THAN 10' DEEP & LESS THAN 20' DEEP 12" 8" 5'-4" FOR LESS THAN 10' DEEP 6'-0" FOR GREATER THAN 10' DEEP & LESS THAN 20' DEEP 12" 8" BUTYL RUBBER JOINTS BELOW PIPE (TYP.) KNOCKOUT AS REQUIRED PROVIDE ADEQUATE BEDDING AS REQUIRED BY CT DOT FORM 817 UN D E R 1 0 ' T O T O P O F F R A M E 18 " ( I N S I D E ) 24 " ( O U T S I D E ) RI S E R H E I G H T V A R I E S (1 ' M I N . ; 4 ' M A X . ) 4'-0"3'-0"3'- 0 " OUTLET HOOD IF REQUIRED 24 " M I N . OUTLET/INLET PIPES (SEE PLAN) 4" MIN. TOP AND BOTTOM 1'-4"1'-8"1'-4" 1'-3"2'-2"11" 1'-3 12"2'-9" 1'-3 12"2'-9" 1'-3 12" 1'-3 12" REDUCED DIMENSION FOR TYPE 'CL' REDUCED DIMENSION FOR TYPE 'C' GRADE RING HEIGHT VARIES 2", 4" & 6" (IF REQUIRED) CORBEL HEIGHT VARIES 8" & 12" 6'-0" TYPE 'C' & 'CL' OVER 10' 5'-4" TYPE 'C' & 'CL' UNDER 10' 4'-0" TYPE 'C' & 'CL' 5' - 0 " T Y P E ' C ' & ' C L ' O V E R 1 0 ' 4'- 4 " T Y P E ' C ' & ' C L ' U N D E R 1 0 ' GUTTER LINE 3' - 0 " T Y P E ' C ' & ' C L ' TWO ROWS OF BUTYL RUBBER FULL MORTAR BED NOTES: 1.PRECAST CONCRETE MANHOLE COMPONENTS SHALL CONFORM TO CTDOT STANDARD SHEET HW-507_10 AS AMENDED. 2.4', 5' OR 6' PRECAST CONCRETE BASE DIAMETERS MAY BE USED WHEN REQUIRED DUE TO SIZE OR NUMER OF PIPES AT THE MANHOLE. PRECAST REDUCERS WILL BE PLACED ABOVE THE 5' AND 6' BASES AS DIRECTED BY THE ENGINEER. WALL THICKNESS SHALL INCREASE 1" FOR EACH 1' OF INSIDE DIAMETER INCREASE. 3.JOINT SEALANT SHALL BE BUTYL RUBBER MASTIC TYPE SEAL THAT CONFORMS TO LATEST AASHTO SPECIFICATION M-198 & MEETS FEDERAL SPECIFICATION SS-S-0021(210-A). 4.REINFORCING STEEL DEFORMED BARS ARE NOT SHOWN AND SHALL CONFORM TO LATEST CTDOT STANDARDS & SUPPLEMENTALS AND ASTM SPECIFICATION A615, GRADE 60, MINIMUM COVER 2", UNLESS OTHERWISE NOTED. 5.ALL PIPE OPENINGS SHALL BE CLOSED USING MATERIALS WHICH CONFORM TO STATE OF CT STANDARD SPECIFICATIONS SECTION M.08.02. 6.REINFORCING STEEL WELDED WIRE FABRIC SHALL CONFORM TO LATEST ASTM SPECIFICATION A185. 7.CONCRETE COMPRESSIVE STRENGTH SHALL BE MINIMUM 4000 PSI AT 28 DAYS, SELF COMPACTING CONCRETE MIX. 8.MANHOLE STEPS SHALL MEET LATEST OSHA REGULATIONS, (29 CFR 1910.27), SECTION 16 OF ASTM SPECIFICATION C478 AND SECTION 10 OF ASTM SPECIFICATION C497. 9.WHEN SPECIFIED, MANHOLES ARE TO BE COATED WITH BAY OIL, "EBONY". 10.METHOD OF MANUFACTURE SHALL BE WET CAST. 11.BASE SECTION IS MONOLITHIC. 12.MANHOLE INTERIOR DIAMETER: 4'-0" FOR 8" TO 36" PIPE DIAMETERS 5'-0" FOR 42" PIPE DIAMETER 6'-0" FOR 48" PIPE DIAMETER. REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW-507_04 & HW-507_10, CT DOT FORM 817 AND (MANHOLE STEPS) THE METROPOLITAIN DISTRICT SEWER STANDARD DETAILS FIG. 5-34, DATED JAN. 2017. COPOLYMER POLYPROPYLENE PLASTIC STEEL REINFORCED MANHOLE STEP FOR CONCRETE MANHOLES A A' A A' STANDARD PRECAST CONCRETE STORM MANHOLE DETAIL NOT TO SCALE END VIEW SECTION A-A' PLAN SIDE VIEW PLANSECTION A-A' SEE STORM MANHOLE FRAME & COVER FOR DETAIL OPENING 24"∅ TYP. (30" OR 36" AVAILABLE) ADJUST TO GRADE WITH MAXIMUM OF 4 COURSES OF BRICK ECCENTRIC CONE HEIGHT VARIES 3', 4' & 5' (W/ 24"∅ OPENING) RISER HEIGHT VARIES1', 2', 3', & 4' BASE HEIGHT VARIES 3', 4', & 6' MANHOLE STEPS (SEE DETAIL) 12" TYP. SEE NOTE #2 FOR MANHOLE DIA. 5" WALL (TYP.) PACK ANNULAR SPACE WITH NON-SHRINK GROUT (TYP. BOTH SIDES)CONCRETE OR BRICK & MORTAR INVERT KNOCKOUTS FOR PIPES 4" MIN. FROM TOP & BOTTOM OF BASE PROVIDE ADEQUATE BEDDING AS REQUIRED BY CT DOT FORM 817 5'-10" DIA. 4" MIN. 6" TYP. COPOLYMER POLYPROPYLENE PLASTIC 1/2" GRADE 60 STEEL REINFORCEMENT PRECAST CONCRETE 1 1316" 1 38" 8 14" 1 316" 15 78" 3 18"5 18" 15 78" 14" CONCRETE OR BRICK INVERT NOTES: 1.REINFORCING STEEL WELDED WIRE FABRIC CONFORMS TO LATEST ASTM SPECIFICATION A185. 2.REINFORCING STEEL DEFORMED BARS CONFORM TO LATEST ASTM SPECIFICATION A615. 3.CONCRETE COMPRESSIVE STRENGTH - 4000 PSI AT 28 DAYS. 4.METHOD OF MANUFACTURE: WET CAST. 5.SECTION IS MONOLITHIC. 6.DESIGN LOAD: AASHTO H-20 4" CAST IRON FRAME AND GRATE YARD DRAIN DETAIL NOT TO SCALE GRATE DETAIL 2'-6" 2'-0" HEIGHTS 1' (BLANK) 2' 30" 3' 4" 16" ∅ KO PANELS, TYP. ALL SIDES RISER DETAIL PLAN VIEW DETAIL 2'-6"2'-0" 2'- 6 " 2' - 0 " DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : DR A I N A G E D E T A I L S 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 DT-2 14 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 2 - 1 6 _ S I T E D E T A I L S . D W G T a b : DR A I N A G E D E T A I L S S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T FINISH GRADE FINISH GRADE VERTICAL SEPARATION DISTANCES NOT TO SCALE HORIZONTAL SEPARATION DISTANCES NOT TO SCALE SEWER UNDER WATER LINE OR STORM SEWER SEWER OVER WATER LINE OR STORM SEWER NOTES: 1.WHEN THE VERTICAL SEPARATION DISTANCE IS 12"-18" THE SEWER SHALL BE PVC CL-150 (SDR 18) FOR A DISTANCE OF 10'-0" ON EITHER SIDE OF THE WATER LINE OR STORM SEWER. WHEN THE SEPARATION DISTANCE IS GREATER THAN 18", STANDARD SEWER PIPE MATERIAL (SDR 35) MAY BE USED. 2.THE SEWER PIPE SHALL BE PVC CL-150 (SDR 18) FOR A DISTANCE OF 10'-0" ON EITHER SIDE OF THE WATER LINE OR STORM SEWER. NO PIPE JOINTS SHALL BE LOCATED WITHIN THE 10' DISTANCE EITHER SIDE. 3.THESE SEPARATION DISTANCES APPLY TO ANY SEWER WITHIN A TOWN RIGHT-OF-WAY OR EASEMENT. NOTES: 1.THESE SEPARATION DISTANCES APPLY TO ANY SEWER WITHIN A TOWN RIGHT-OF-WAY OR EASEMENT. 2.HORIZONTAL RESTRICTIONS FOR STORM SEWER ONLY APPLY WHEN PIPES ARE AT THE SAME ELEVATION. 12" MIN. (SEE NOTE #1) 18" MIN. GRAVITY OR FORCE MAIN SEWER PVC CL-150 (SDR 18) (SEE NOTE #2) WATER MAIN/SERVICE STORM SEWER WATER MAIN/SERVICE STORM SEWER GRAVITY OR FORCE MAIN SEWER GRAVITY OR FORCE MAIN SEWER WATER MAIN/SERVICE 10'-0" MIN. STORM DRAIN 1'-6" MIN. PLAN DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : UT I L I T Y D E T A I L S 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 DT-3 15 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 2 - 1 6 _ S I T E D E T A I L S . D W G T a b : UT I L I T Y D E T A I L S S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M 8" MIN. TO 21" MAX. (ADJUST TO GRADE WITH SEWER BRICK OR MANHOLE RINGS) 4' DIA. 30" 24" 6" MIN. 6"6"6" MIN. STANDARD TOP CONE 1"x1" BUTYL RUBBER GASKET AT ALL JOINTS 4'-0" MAX. DIMENSION TO FIRST PIPE JOINT'KOR-N-SEAL' RUBBER BOOT OR EQUAL 12" O.C. CAST IRON MANHOLE FRAME & COVER FINISHED GRADE COAT ENTIRE SURFACE WITH 2 COATS OF BIT. WATERPROOFING STEPS (PRECAST INTO WALL SECTIONS) COPOLYMER LADDER RUNGS 5" STANDARD RISERS (AS NEEDED) STANDARD BASE TOP OF BENCH HEIGHT TO CROWN CONCRETE OR BRICK TABLE NOTE: BASE, RISERS AND TOP CONE TO BE CONSTRUCTED OF PRE-CAST REINFORCED CONCRETE. 3/4" CRUSHED STONE BASE SLOPE SLOPE SEWER MANHOLE DETAIL NOT TO SCALE 45°+ NOTES: 1.SEWER SADDLE TO BE STYLE "CB" SEWER SADDLE MANUFACTURED BY ROMAC INDUSTRIES, INC. MODEL NO. CB-6.30 (8-12" PIPE), NO.CB-6.30LS (12-24" PIPE), OR APPROVED EQUAL. 2.CORE HOLE IN AC OUR VCT MAIN USING APPROVED HOLE CUTTING TOOL. 3.HOUSE LATERAL SHALL BE 6" PVC PIPE CONFORMING TO DW. NO. SCS-101, 102 OR 103. AC = ASBESTOS CEMENT ("TRANSITE") VCT = VITREOUS CLAY TILE PVC/AC/VCT SEWER PIPE FIELD CONNECTION NOT TO SCALE PAVEMENT REPLACEMENT DETAIL NOT TO SCALE EXISTING PAVEMENT SAWCUT EXISTING PAVEMENT, APPLY TACK COAT COMPACTED SUBGRADE OR UNDISTURBED MATERIAL 2-1/2" WEARING COURSE, CLASS 2 2-1/2" BINDER COURSE, CLASS 1 (2) 6" LAYERS OF COMPACTED PROCESSED AGGREGATE (M.05.01) TRENCH WALL 17 " REMOVE EXISTING PAVEMENT 18" FROM LIMITS OF TRENCH (TYP. BOTH SIDES) EXISTING SUBBASE UNDISTURBED MATERIAL COARSE SAND (CONNDOT M.03.01.2) OR APPROVED NATIVE FILL TAMPED NOTES: 1.SELECT BACKFILL MATERIAL SHALL BE BANK-RUN GRAVEL GRADATION C, FORM 817, 2019, OR PROCESSED AGGREGATE CAN BE USED IN LIEU OF BANK-RUN GRAVEL OR APPROVED NATIVE MATERIAL. 2.ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CONNECTICUT DOT STANDARD SPECIFICATIONS FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION FORM 817, 2019 OR AS AMENDED. 3.ALL UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH ALL MUNICIPAL AND UTILITY AUTHORITY REQUIREMENTS AND SPECIFICATIONS. 4.ALL PROPOSED MATERIALS SHALL BE INSTALLED AS SHOWN OR MATCH EXISTING CONDITIONS AS APPROVED BY THE MUNICIPALITY. 5.CONTRACTOR RESPONSIBLE FOR EXCAVATION, BEDDING, CONDUIT & BACKFILL. 3", 2" AND 3" SCH. 40 PVC CONDUIT FOR POWER, TELEPHONE AND CABLE T.V. RESPECTIVELY CABLEPHONEELEC PAVEMENT SECTION (SEE DETAIL) 12"12"6" 12 " M I N . 6" TYPICAL E/T/C UTILITY TRENCH NOT TO SCALE PAVEMENT REPAIR AS REQUIRED BY LOCAL AUTHORITY 12" 30 " M I N . (O R P E R C U S T O D I A L UT I L I T Y R E Q U I R E M E N T ) FINISHED GRADE SELECT BACKFILL MATERIAL TAMPLED OR APPROVED NATIVE MATERIAL 6" DETECTIBLE MARKING TAPE PER CUSTODIAL UTILITY REQUIREMENTS SAWCUT & CLEAN EXISTING PAVEMENT AND PAINT EDGES WITH CUT BACK ASPHALT EXISTING PAVEMENT TYPICAL TRENCH NOT TO SCALE 3/4" CRUSHED STONE OR PROCESSED GRAVEL (85% COMPACTION) 0.25 O.D.PL A C E D BY H A N D APPROVED GRANULAR BACKFILL OR SUITABLE NATIVE MATERIAL COMPACTED IN 8" (MAX) LAYERS. 6" MIN. (OVER EARTH) OR 12" MIN. (OVER LEDGE) COMPACTED FINE BEDDING UNDER PIPE D + 24" BANK RUN GRAVEL BASE OR APPROVED GRAVEL BACKFILL MATERIAL. COMPACTED IN 8" (MAX.) LAYERS. SAND TO BE USED FOR SANITARY PIPE PIPE: -STORM TO BE HDPE OR RCP CLASS IV OR V -SANITARY TO BE SDR35 PVC OR SCH. 40 -WATER TO BE TYPE K COPPER OR PE3408 TO 2". DUCTILE IRON > 2" NOTES: 1.SELECT BACKFILL MATERIAL SHALL BE BANK-RUN GRAVEL GRADATION C, FORM 817, 2019, OR PROCESSED AGGREGATE CAN BE USED IN LIEU OF BANK-RUN GRAVEL OR APPROVED NATIVE MATERIAL. 2.ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CONNECTICUT DOT STANDARD SPECIFICATIONS FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION FORM 817, 2019 OR AS AMENDED. 3.ALL UTILITIES SHALL BE INSTALLED IN ACCORDANCE WITH ALL MUNICIPAL AND UTILITY AUTHORITY REQUIREMENTS AND SPECIFICATIONS. 4.ALL PROPOSED MATERIALS SHALL BE INSTALLED AS SHOWN OR MATCH EXISTING CONDITIONS AS APPROVED BY THE MUNICIPALITY. 2.USE WATERTIGHT RUBBER CASKETS ASTM C443 IN ALL PIPE JOINTS. PAVEMENT SECTION (SEE DETAIL) PAVEMENT REPAIR AS REQUIRED BY LOCAL AUTHORITY 12" 4'-6" MIN. COVER FOR WATER MAINS 2'-3" MIN. COVER FOR SANITARY SEWER LATERIALS FINISHED GRADE 6" DETECTIBLE MARKING TAPE PER CUSTODIAL UTILITY REQUIREMENTS SAWCUT & CLEAN EXISTING PAVEMENT AND PAINT EDGES WITH CUT BACK ASPHALT EXISTING PAVEMENT 12 " MI N . 12"12"D D/ 4 29798No. M.M A R O NS A M E U S LICE N S ED R P F O SE ISONA L NE IG EN S ER STATE O F C ONNECT C I U T SPILLWAY LENGTH 2:1 ( M A X . ) GEOTEXTILE FABRIC 12" THICK CTDOT MODIFIED RIPRAP M12.02 2:1 (MAX.) SPILLWAY DETAIL BIORETENTION BASIN X-SECTION NOT TO SCALE BIORETENTION BASIN CONSTRUCTION SEQUENCE: 1.REMOVE EXISTING TOPSOIL, SURFACE LEAF LITTER, ETC. FROM BIORETENTION BASIN AREA AND STOCKPILE FOR REUSE. 2.AVOID COMPACTION OF NATURAL SOILS WITHIN BOTTOM AREA OF BIORETENTION BASIN BY CONSTRUCTION EQUIPMENT. THE AREA OF THE BIORETENTION BASIN SHALL BE MARKED OFF BY APPROPRIATE FENCING TO PREVENT THE MOVEMENT OF CONSTRUCTION VEHICLES OVER AND THE POSSIBLE COMPACTION OF THE NATURAL SOILS. 3.SCARIFY NATURAL SOILS WITHIN THE BOTTOM OF BASIN PRIOR TO PLACING SOIL MEDIA. 4.MIX BIORETENTION SOIL MEDIA. SOIL MEDIA SHALL CONSIST OF THE FOLLOWING: A.60-85% ASTM C-33 SAND B.15-25% TOPSOIL. TOPSOIL SHOULD CONTAIN 5-20% ORGANIC MATERIAL, HAVE LESS THAN 5% CLAY, BE A SANDY LOAM, LOAMY SAND OR LOAM, AND HAVE A pH RANGE OF 5.5-7.0. C.3-8% ORGANIC MATTER. ORGANIC MATTER SHALL CONSIST OF PARTIALLY DECOMPOSED PEAT MOSS (100% PASSING THE 1/2" SIEVE) OR WOOD DERIVATIVES (SHREDDED WOOD, WOOD CHIPS, GROUND BARK). 5.SOIL MEDIA PROVIDE FOR A MINIMUM INFILTRATION RATE OF 1.0 INCHES/HOUR. CONTRACTOR SHALL HAVE THE SOIL MEDIA TESTED PRIOR TO PLACEMENT. THE DESIGN ENGINEER SHALL REVIEW AND CERTIFY THAT THE SOIL MEDIA MEETS THE SOIL MEDIA SPECIFICATIONS. 6.PLACE SOIL MEDIA IN THE BASIN IN 6-12" LIFTS USING LIGHT EQUIPMENT. ALLOW SOIL TO SETTLE NATURALLY THROUGH RAIN EVENTS OR PRESOAK AFTER PLACEMENT. 7.SIDE SLOPES AND ALL AREAS DISTURBED OUTSIDE THE BASIN SHALL BE FINE GRADED WITH 6" TOPSOIL, RAKED, SEEDED AND MULCHED. 8.SEED BOTTOM OF BASIN WITH NEW ENGLAND WETLAND PLANTS, INC. ROADSIDE SEED MIX AT 1 LB/1,250 S.F., OR EQUIVALENT. SEED SIDES AND BOTTOM WITH NEW ENGLAND WETLAND PLANTS, INC. EROSION CONTROL/RESTORATION MIX FOR DRY SITES SEED MIX AT 1 LB/1,250 S.F. OR EQUIVALENT. SEEDING SHALL BE QUICKLY ESTABLISHED AND MAINTAINED TO PREVENT ANY SILT ACCUMULATION ALONG THE BOTTOM OF THE BASIN. MINIMUM VEGETATIVE COVERAGE OF 90% SHALL BE TARGETED AND MAINTAINED. 9.BIORETENTION BASIN SHALL NEVER BE USED FOR SEDIMENT CONTROL DURING AN ACTIVE CONSTRUCTION PERIOD. 10.DURING CONSTRUCTION, SEDIMENT SHALL BE PREVENTED FROM ENTERING THE AREA OF THE BASIN. THE CONTRACTOR SHALL ENSURE THAT THE AREAS DRAINING TO THE BIORETENTION BASIN ARE STABILIZED IN A TIMELY MANNER AND MAINTAINED OVER THE ENTIRE AREA DRAINING TO THE BASIN. 11.DESIGN ENGINEER SHALL INSPECT THE INSTALLATION OF THE BIORETENTION BASIN DURING THE FOLLOWING STAGES OF CONSTRUCTION: A.AFTER EXCAVATION OF THE BASIN AND SCARIFICATION OF BOTTOM AND SIDEWALLS OF EXCAVATION. B.AFTER PLACEMENT OF BIORETENTION SOIL MEDIA. 12.A LICENSED LAND SURVEYOR SHALL PROVIDE AN AS-BUILT OF THE DETENTION BASIN/SAND FILTER. DESIGN ENGINEER SHALL CERTIFY THAT THE SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE DESIGN PLANS. BIORETENTION BASIN MAINTENANCE PLAN: 1.IN THE FIRST 6 MONTHS FOLLOWING CONSTRUCTION, THE BIORETENTION BASIN SHALL BE INSPECTED AFTER STORM EVENTS OF 1" OR GREATER. FOLLOWING THE FIRST 6 MONTHS, THE BASIN SHALL BE INSPECTED EVERY 6 MONTHS (SPRING AND FALL) AND/OR AFTER STORM EVENTS OF 2" OR GREATER. INSPECTIONS SHALL INCLUDE THE FOLLOWING: A.INSPECT SOIL MEDIA FOR STANDING WATER OR OTHER EVIDENCE OF CLOGGING. B.CHECK FOR SEDIMENT ACCUMULATION, TRASH, AND DEBRIS. C.CHECK FOR BLOCKAGES, STRUCTURAL INTEGRITY, AND EVIDENCE OF EROSION AT INLETS/OUTLETS. 2.REGULAR MAINTENANCE INCLUDES THE FOLLOWING: A.REMOVE SEDIMENT, TRASH AND DEBRIS. B.REMOVE ACCUMULATED SEDIMENT FROM THE BASIN WHEN THE SEDIMENT ACCUMULATION EXCEEDS 1", OR WHEN DRAWDOWN TIME EXCEEDS 48 HOURS AFTER THE END OF A STORM EVENT. REPLACE WITH FRESH BIORETENTION SOIL MEDIA THAT CONFORMS TO THE SPECIFICATIONS IN THIS SECTION. C.MAINTAIN VEGETATED FILTER STRIPS OR GRASSED SIDE SLOPES OF BIORETENTION SYSTEM. D.MOW THE BASIN IN THE FALL AFTER THE FIRST KILLING FROST TO REMOVE SAPLINGS AND WOODY BRUSH AND SUBSEQUENT PERIODIC MOVING FOR MAINTENANCE. MOWING SHOULD NOT BE PERFORMED WHEN THE GROUND IS SOFT TO AVOID THE CREATION OF RUTS AND COMPACTION, WHICH CAN REDUCE INFILTRATION. E.PERIODICALLY REMOVE GRASS CLIPPINGS TO PREVENT CLOGGING OF THE SURFACE OF THE BIORETENTION SYSTEM. F.REMOVE ANY INVASIVE SPECIES (INCLUDING ROOTS) THAT HAVE BECOME ESTABLISHED WITHIN THE BASIN AND EMBANKMENTS. 3.BIORETENTION BASIN REQUIRES OTHER SEASONAL LANDSCAPE MAINTENANCE, INCLUDING: A.WATERING PLANTS AS NECESSARY DURING FIRST GROWING SEASON. B.WATERING AS NECESSARY DURING DRY PERIODS. C.REPLACING DEAD OR DYING PLANTS, OR PRUNING PLANTS, AS NECESSARY. D.INSPECTION OF SOIL AND REPAIRING ERODED AREAS. BOTTOM OF BASIN/ TOP OF SOIL MIX ELEV. C TOP OF BERM ELEV. A. TOP OF SPILLWAY ELEV. B NON-WOVEN GEOTEXTILE FABRIC SEED BOTTOM OFBASIN, SIDE SLOPES AND TOP OF BERM OUTLET CONTROL STRUCTURE 18" BIORETENTION SOIL MEDIA NON-COMPACTED ORIGINAL SUBGRADE NON-WOVEN GEOTEXTILE FABRIC 36 " T O S H G T REINFORCED CONCRETE FLARED END SECTION NOT TO SCALE NOTES: 1.ALL PRECAST CONCRETE PRODUCTS MUST HAVE THE CASTING DATE CLEARLY LABELED AND SHALL NOT BE DELIVERED WITHIN 7 DAYS OF THE CASTING DATE. 2.JOINT SHALL BE TONGUE AND GROOVE OR BELL AND SPIGOT AS REQUIRED TO CONFORM TO PILE INSTALLED. 3.WALL THICKNESS SHALL CONFORM TO PIPE THICKNESS. REINFORCED CONCRETE PIPE CONFORMS TO ASTM C-76, ASTM-C-443, ASHTO M-170, AND AASHTO M-198. DIA.A B C D E R1 R2 12"4"24"48 7/8"24"3"10 1/4"9" 15"6"27"46"30"3"12 1/2"11" 18"9"27"46"36"3"15 1/2"12" 24"9-1/2"43-1/2"30"48"3"16 13/16"14" 30"12"54"19-3/4"60"3 1/2"18 1/2"15" 36"15"63"34-3/4"72"4"24 5/16"20" 42"21"63"35"78"4 1/2"27 1/2"22" 48"24"72"26"84"5 28 1/2"22" 54"27"65"35"90"5 1/2"33 1/8"24" 60 30"60"39"96"6"36 11/16"24" DI A . WA L L WA L L C B A TONGUE OR GROOVE DI A . + 1 " WALL E WALL WA L L D WA L L DIA. X X R2 DI A . SECTION X-X R1 R=1 1/2" RIPRAP APRON DIMENSIONS OUTLET W1 La W2 FES-1 6 26 25 FES-2 6 27 25 FES-3 6 26 25 FES-4 6 24 23 FES-5 4 10 11 FES-6 4 8 10 NOTE: IN ACCORDANCE WITH CT DOT DRAINAGE MANUAL SECTION 11.13 - OUTLET PROTECTION, THE APRON STONE FOR FES-1, 2, 3, AND 4 SHALL BE STANDARD RIPRAP (DISCHARGE VELOCITIES 10-14 FT/S), AND THE APRON STONE FOR FES-5 AND 6 SHALL BE MODIFIED RIPRAP (DISCHARGE VELOCITIES 0-8 FT/S). RIPRAP APRON NOT TO SCALE W1 W2 La CONCRETE FLARED END SECTION 12" MODIFIED RIPRAP 6" PROCESSED GRAVEL NON-WOVEN GEOTEXTILE FABRIC HDPE TO CONCRETE PIPE CONNECTION (SEE DETAIL)NE W G R A D E HDPE PIPE TOP OF BERM ELEV. A TOP OF SPILLWAY ELEV. B DE S C R I P T I O N O F R E V I S I O N DRAWING SHEET NUMBER:OF CHECKED BY:DATE: DRAWN BY:DATE: PROJECT NO.SCALE: DA T E AP P R . RE V . H HENGINEERINGASSOCIATES 232 Greenmanvijlle Ave. Sƞijte 201 MƼƊtijc, CT 06355 860-980-8008 ƶƶƶ.hh-enħijneerƊ.com PR E P A R E D F O R : PR O P E R T Y A D D R E S S : ST O R M W A T E R M A N A G E M E N T D E T A I L S 23 - L O T R E S I D E N T I A L R E S U B D I V I S I O N 47 S H A R P H I L L R O A D , M O N T V I L L E , C T 0 6 3 8 2 MT K I N E O B U I L D E R S , L L C P. O . B O X 2 4 6 , W E S T M Y S T I C , C T 0 6 3 8 8 2025-0197 AS NOTED SMM 7/10/2025 SMM 7/10/2025 DT-4 16 16 1 RE V I S I O N S I N R E S P O N S E T O R E V I E W C O M M E N T S 8/ 1 5 / 2 0 2 5 SM M Z:\ S H A R E D \ H + H E N G I N E E R I N G A S S O C I A T E S \ P R O J E C T S \ 2 0 2 5 \ 2 0 2 5 - 0 1 9 7 - M T K I N E O B U I L D E R S - 4 7 S H A R P H I L L R D , M O N T V I L L E \ D W G S \ 1 2 - 1 6 _ S I T E D E T A I L S . D W G T a b : SW M D E T A I L S S a v e d : 8/ 1 5 / 2 0 2 5 1 : 4 6 P M P l o t t e d : 8/ 1 5 / 2 0 2 5 1 : 4 9 P M INFILTRATION TRENCH CONSTRUCTION SEQUENCE: 1.EXCAVATE TRENCH TO ELEVATION 360.0. 2.INSTALL OBSERVATION WELL IN TRENCH. BOTTOM OF OBSERVATION WELL SHALL BE PLACED AT BOTTOM OF TRENCH. 3.BACKFILL SAND & STONE IN 6-9" LIFTS. INSTALL SAND & STONE USING LIGHT EQUIPMENT THAT WILL NOT RESULT IN THE COMPACTION OF THE SOIL WITHIN THE TRENCH. 4.DESIGN ENGINEER SHALL INSPECT THE INSTALLATION OF THE INFILTRATION TRENCH DURING THE FOLLOWING STAGES OF CONSTRUCTION: A.AFTER EXCAVATION OF THE TRENCH AND SCARIFICATION OF BOTTOM AND SIDEWALLS OF EXCAVATION. B.AFTER INSTALLATION OF THE OBSERVATION WELL AND SAND. C.AFTER PLACEMENT AND LEVELING OF WASHED STONE LAYER. D.AFTER PEA GRAVEL SURFACE COVER HAVE BEEN INSTALLED. 6.DESIGN ENGINEER SHALL CERTIFY THAT THE SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE DESIGN PLANS. INFILTRATION TRENCH MAINTENANCE PLAN: THE INFILTRATION TRENCH SHALL BE CLEANED AT THE END OF CONSTRUCTION ONCE THE CONTRIBUTING AREAS ARE FULLY STABILIZED. FOR THE FIRST 6 MONTHS AFTER CONSTRUCTION, THE INFILTRATION TRENCH SHALL BE INSPECTED AFTER MAJOR STORMS (1" OR MORE OF PRECIPITATION). AFTER THE FIRST 6 MONTHS OF OPERATION, THE INFILTRATION TRENCH SHALL BE INSPECTED ANNUALLY, AND AN INSPECTION REPORT SHALL BE COMPLETED AND FILED WITH MANAGEMENT STAFF. TYPICAL MAINTENANCE SHALL INCLUDE THE FOLLOWING: 1.REMOVE TRASH AND ORGANIC DEBRIS (LEAVES). 2.REMOVE SEDIMENT FROM THE INFILTRATION TRENCH SURFACE WHEN THE SEDIMENT ACCUMULATION EXCEEDS 2" OR WHEN DRAWDOWN TIME EXCEEDS 48 HOURS AFTER THE END OF A STORM EVENT, INDICATING THAT THE SOIL MEDIA IS CLOGGED. 3.WEED AS NECESSARY. 4.MOW GRASS WITHIN PROXIMITY OF THE INFILTRATION TRENCH TO A HEIGHT OF 4" TO 6". 5.PERIODICALLY REMOVE GRASS CLIPPINGS TO PREVENT CLOGGING OF THE SURFACE OF THE INFILTRATION TRENCH. OUTLET CONTROL STRUCTURE ELEVATION SUMMARY TABLE STRUCTURE ID TOP OF FRAME ELEV. A UPPER ORIFICE INVERT ELEV. B MIDLE ORIFICE INVERT ELEV. C LOWER ORIFICE INVERT ELEV. D OUTLET PIPE INVERT ELEV. E OCS-1 356.25 -----355.75 (48"(W) x 6"(H))345.00 (24") OCS-2 346.75 -----346.25 (48"(W) x 6"(H))339.00 (24") OCS-3 342.00 --340.90 (48"(W) x 6"(H)) 339.15 (48"(W) x 6"(H))335.00 (21") OCS-4 391.25 390.75 (24"(W) x 6"(H)) 390.00 (18"(W) x 46"(H)) 339.15 (6"(W) x 46"(H))385.50 (15") BASIN ELEVATIONS BASIN ID TOP OF BERM ELEV. A TOP OF SPILLWAY ELEV. B BOT. OF BASIN ELEV. C WATER QUALITY BASIN 357.00 356.50 354.00 BASIN 'A'347.50 347.00 343.50 BASIN 'B'344.00 343.00 338.00 BASIN 'C'392.00 391.50 388.00 INFILTRATION TRENCH X-SECTION NOT TO SCALE (3") 3/8" NO. 8 WASHED CRUSHED STONE OR PEA GRAVEL 1.5"-3.0" WASHED CRUSHED STONE OBSERVATION WELL - PERFORATED 4" PVC PIPE WITH LOCKABLE ABOVE GROUND CAP 24" GRASS SIDE SLOPES (3:1 MAX.) NON-WOVEN FILTER FABRIC ON SIDES AND TOP OF STONE UNDISTURBED NATIVE SOIL. IF FILL MATERIAL, REPLACE FILL MATERIAL WITH ASTM C-33 SAND TO SHGT VA R I E S ( 1 . 0 ' - 5 . 5 ' ) 36 " T O SH G T 12" (TYP.) 12 " (T Y P . ) 8" 5" 3" BOTTOM OF BASIN OUTLET PIPE INVERT ELEV. E 5' - 4 " 4'- 0 " WEIR 5'-4" 1'- 0 " BASIN OUTLET CONTROL STRUCTURE NOT TO SCALE PLAN VIEW TOP OF FRAME ELEV. A FRONT VIEW NOTCH DETAIL LOWER ORIFICE INVERT ELEV. D UPPER ORIFICE INVERT ELEV. B MID ORIFICE INVERT ELEV. C TEST HOLE 101 0"-11"TOPSOIL 11"-28"ORANGE-BROWN FINE SANDY LOAM 28"-40"MEDIUM SAND W/ COBBLES 40"-48"BROWN VERY FINE SAND W/ SILT 48"-75"TAN FINE-MEDIUM SAND NO MOTTLING NO GROUNDWATER NO LEDGE TEST PIT RESULTS DATE: MARCH 27, 2025 RECORDED BY: SEAMUS MORAN, P.E. (H+H ENGINEERING ASSOCIATES, LLC) TEST HOLE SAMPLE DEPTH (INCHES) PERMEABILITY (FT/DAY) 101 30 13.0 102 27 0.1 104 33 3.8 105 30 8.2 PERMEABILITY RESULTS DATE: MARCH 27, 2025 COLLECTED BY: SEAMUS MORAN, P.E. (H+H ENGINEERING ASSOCIATES, LLC) TESTED BY: CLA ENGINEERS TESTING METHOD: FALLING HEAD PERMEABILITY TEST TEST HOLE 102 0"-11"TOPSOIL 11"-30"ORANGE-BROWN FINE SANDY LOAM 30"-53"GRAY VERY FINE SAND W/ SILT 53"-65"BROWN VERY FINE SAND 65"-73"TAN FINE SAND 73"-93"BROWN-GRAY COARSE SAND & GRAVEL MOTTLING @ 38" (PERCHED GROUNDWATER) NO GROUNDWATER NO LEDGE TEST HOLE 103 0"-18"TOPSOIL 18"-30"BROWN VERY FINE SAND W/ SILT 30"-35"GRAY VERY FINE SAND W/ SILT, MOTTLED 55"-80"ORANGE-BROWN COARSE SAND &GRAVEL MOTTLING @ 36" (POSSIBLY PERCHED GROUNDWATER) NO GROUNDWATER NO LEDGE ROOTS TO 61" TEST HOLE 104 0"-8"TOPSOIL 8"-28"ORANGE-BROWN FINE SANDY LOAM 28"-33"GRAY VERY FINE SAND W/ SILT 33"-55"ORANGE MEDIUM-COARSE SAND W/ FRAGMENTED ROCK 55"-90"DARK GRAY/BROWN COARSE SAND MOTTLING @ 31" (PERCHED GROUNDWATER) NO GROUNDWATER NO LEDGE ROOTS TO 61" TEST HOLE 105 0"-16"TOPSOIL 16"-50"ORANGE-BROWN FINE-MEDIUM SAND 50"-68"BROWN VERY FINE SANDY LOAM W/ SILT 68"-92"BROWN FINE SAND NO MOTTLING GROUNDWATER @ 88" NO LEDGE ROOTS TO 61"