Loading...
HomeMy WebLinkAbout25SITE2 - Sewer & Water System Calculations 03-18-2025FULLER ENGINEERING & LAND SURVEYING, LLC 525 John Street · Second Floor Bridgeport, CT 06604 (203) 333-9465 (203) 336-1769 FAX FULLER ENGINEERING & LAND SURVEYING, LLC 525 JOHN STREET 2ND FLOOR BRIDGEPORT, CONNECTICUT 06604 PHONE (203)333-9465; FAX (203)336-1769 SANITARY SEWER & WATER SYSTEM CALCULATIONS Project Name: Madison Place Luxury Townhouse Development 18 Powerhouse Road & 145 CT Route 32 Montville, CT Information prepared for: JNE Holdings, LLC & Town of Montville Department of Public Works / Engineering Department Dated: 18 March 2025 Atlantic Consulting & Engineering PAGE M1 -3 525 John Street • Second Floor Bridgeport, CT 06604 (203) 336-4422 (203) 336-1769 FAX Project: RESIDENTIAL DEVELOPMENT @ #145 ROUTE 32 Date: 03-18-2025 MONTVILLE, CT 0 SANITARY SEWER DESIGN FLOW TABLE (PROPOSED CONDITIONS) QTY UNITS GPD/UNIT GPD/TOTAL 0 1 BEDROOM UNIT 150 - 0 2 BEDROOM UNIT 300 - 11 3 BEDROOM UNIT 450 4,950.00 ADF (AVE DAILY FLOW)TOTAL 4,950.00 GPD ADF (AVE DAILY FLOW)TOTAL 0.005 MGD DF = ADF X PEAKING FACTOR DF = DESIGN FLOW PF = PEAKING FACTOR PF = 4.0 DF =19,800.00 GPD (65000 GPD = 0.1 CFS)0.0305 CFS References: 1) CONNECTICUT PUBLIC HEALTH CODE On-site Sewage Disposal Regulations and Technical Standards for Subsurface Disposal Systems Revised January 1, 2023 2) CONNECTICUT PUBLIC HEALTH CODE Sections 19-13-B104a through 19-13-B104d Atlantic Consulting & Engineering PAGE M1 -5 525 John Street • Second Floor Bridgeport, CT 06604 (203) 336-4422 (203) 336-1769 FAX Project: RESIDENTIAL DEVELOPMENT @ #145 ROUTE 32 Date: 03-18-2025 MONTVILLE, CT 0 CALCULATE THE CAPACITY OF SAN. SEWER PIPE PIPE:PROPERTY TO MAIN Pipe Diameter:6 inches PVC MANNINGS EQUATION R =____A___0.125 PW Where R:Hydraulic radius (ft) A:Cross-sectional area (ft2)0.1963495 PW:Wetted Perimeter (ft)1.5707963 V=k R2/3 S1/2 4.789041382 n Where V:Mean Velocity (ft/s) k:1.49 for U.S. customary units, or 1.0 for S.I. units n:Manning's roughness value 0.011 R:Hydraulic Radius (ft)0.125 S:friction Slope (ft/ft)0.02 Q=VA 0.940326076 Where Q:Flow Rate(cfs) V:Average velocity (ft/s) Design Flow Calculated (SEE SAN SEWER DESIGN FLOW TABLE) =0.0305 CFS The Q capacity of the pipe is higher than the design flow therefore pipe is sufficient 0.9403 CFS > 0.0305 CFS therefore OK 611,212 GPD > 19,800 GPD Note: Existing units 1 and 7 are proposed to retain their ex-water sewer connections. However, they were included in this calculations Atlantic Consulting & Engineering PAGE M1 -5 525 John Street • Second Floor Bridgeport, CT 06604 (203) 336-4422 (203) 336-1769 FAX Project: RESIDENTIAL DEVELOPMENT @ #145 ROUTE 32 Date: 03-18-2025 MONTVILLE, CT WATER DEMAND CALCULATIONS pg.1 No.Total 33.0 118.8 11.0 15.4 11.0 15.4 11.0 15.4 Hose Bibb 1.0 --1.0 3.0 3.0 168.0TOTAL * BATHROOM GROUP. A group of fixtures, including or excluding a bidet, consisting of a water closet, lavatory, and bathtub or shower. Such fixtures are located together on the same floor level. (2022 CT Building Code) ** Fire Service Provided by Existing Hydrant on Power House Rd Atlantic Consulting & Engineering PAGE M1 -5 525 John Street • Second Floor Bridgeport, CT 06604 (203) 336-4422 (203) 336-1769 FAX Project: RESIDENTIAL DEVELOPMENT @ #145 ROUTE 32 Date: 03-18-2025 MONTVILLE, CT WATER DEMAND CALCULATIONS pg.2 2 in Pipe recommended * Based on (2022 CT Connecticut State Building Code)