HomeMy WebLinkAbout1365 Old Colchester Rd. Septic system Design PLanZONING COMPLIANCE TABLE - R-120 DISTRICT
(PART OF CLUSTER SUBDIVISION)
ITEM
REQUIRED
PROPOSED
LOT AREA
120,000 S.F.
80,000 S.F.
127,595 S.F.±
LOT FRONTAGE
200 FT./150 FT.
265.54'
FRONT YARD
60 FT./45 FT.
107.0' (GARAGE)
SIDE YARD
25 FT./18.75'
60.5'
REAR YARD It
60 FT./45 FT.
182.0' (DECK)
BUILDING HEIGHT-][::::3
5 FT.
28 FT.
*THIS LOT IS PART OF A CLUSTER SUBDIVISION
"FRONTAGE, FRONT YARD, SIDE YARD & REAR YARD
REQUIREMENTS ARE REDUCED BY 25%
I Ncti
496
•
NET
#13
478
o
_ 5
h*Nil (o6a,13 5
1
PROPOSED
UTILITY s
POLE t
PROVIDE A NON -TRACKING iDIN _
CONSTRUCTION ENTRANCE ,yob REC/
(SEE DETAIL) i
I
PROVIDE PAVED APRON
TO STREETLINE
FILTER
FABRIC
ANGLE 100 UP SLOPE
POST FOR STABILITY AND
a fNo SELF CLEANING
z �
COMPACTED Q
BACKFILL
SILT FENCE
NOT TO SCALE
LEGEND:
F.F. FIRST FLOOR 4oPo
EL. ELEVATION
S.F. SQUARE FEET
MON MONUMENT
IPIN IRON PIN
REC. RECOVERED
x501.5 EXISTING SPOT ELEVATION
x507.5 PROPOSED SPOT ELEVATION
- 500 - - EXISTING CONTOURS lt�1J
{-500 PROPOSED CONTOURS F
BUILDING SETBACK LINE AeR�C
-�• TEST HOLE
CONSTRUCTION ENTRANCE
NOT TO SCALE
TEST HOLE DATA
PERC TEST DATA
ADVANCED SURVEYS, LLC - 8/27/24
UNCAS HEALTH DISTRICT
EROSION AND SEDIMENT CONTROL PLAN:
PERC "A" HOUSE SEPTIC AREA.
DEPTH - 24"
PER SUBDIVISION PLAN - 4/27/2000
WITNESSED BY DONOVAN MOE - 8/26/24 UNCAS HEALTH DISTRICT 1. CLEARING GRUBBING AND GRADING OF THE PROPOSED SITE
PER SUBDIVISION PLAN - LOT 44/8-000
PRESOAK- 1 HR
4, f4
TH# H7A - 0 -11 TOPSOIL
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
TH "A" - 0"-10" TOPSOIL DRIVEWAY AND SEPTIC SYSTEM.
10:50 - 4 3/8" PERC RATE - 10 MINUTESANCH
11:00 - 8 1/4"
- 11 "32" SUBSOIL
- 10"-36" BROWN FINE SANDY LOAM 2. DISTURBED AREAS TO BE LOAMED SEEDED AND MULCHED.
11:10 - 111/2"
- 34"-43" MED. COMPACT FINE TO VERY FINE SAND & SILT - 33"-88" GRAY MED. COMPACT FINE SAND 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
"-78"
11:20 - 14 1/4"
- 43 MED. COMPACT COARSE TO VERY FINE SAND & SILT,ROCKS MOTTLES @ 36" WITH HAYBALES OR SILT FENCE.
y�'18
11:25 - 15 1/4"
MOTTLES 32"
NO GROUNDWATER, NO LEDGE 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
11:30 - 16 1/8'"
GROUNDW TER 58" NO LEDGE
ROOTS TO 24 5• PRIOR TO SITE DISTURBANCE; THE REPRESENTATIVE OF THE
"
11:35 -16 7/8"
" TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
11:40 - 17 5/8"
f4
TH# H7B - 0 -id TOPSOIL
" ,4 CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
TH B - Of'- 10 TOPSOIL
"
11:45 - 18 3/8"
11:50 - 19 1/8
CAN OCCUR.
- 10"-34" SUBSOIL - 10"-32" BROWN FINE SANDY LOAM
" �� �� 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION
- 34 -43 MED. COMPACT FINE TO VERY FINE SAND & SILT,ROCKS - 32 -90 GRAY MED. COMPACT FINE SAND
PERC RATE - 6,6 MINUTES PER INCH
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
- 43"-78" MED. COMPACT COARSE TO VERY FINE SAND & SILT MOTTLES @ 32" MEASURES THROUGHOUT CONSTRUCTION.
MOTTLES @ 32"
NO GROUNDWATER, NO LEDGE 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
--
GROUNDWATER@63 ", NO LEDGE
ROOTS TO 24" WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
S 71000&g,6
TH# H7C - 0"43" TOPSOIL
- 13" 301e SUBSOIL
TH "C" - 0"-12" TOPSOIL TEMPORARY VEGETATIVE COVER:
ZZ,
- 30 43 MED. COMPACT FINE TO
- 12�"-40�" BROWN FINE SANDY LOAM
VERY FINE SAND & SILT,ROCKS - 40 -74 GRAY MED. COMPACT FINE SAND MULCHES APPLICATION RATE NOTES
488
- 43"-75" MED. COMPACT COARSE TO VERY FINE
SAND & SILT MOTTLES @ 40" PER 1000 S.F.
\� 4S
3s
394,
NO MOTTLES
GROUNDWATER@53",
NO GROUNDWATER, NO LEDGE
NO LEDGE
ROOTS TO 22" STRAW/HAY 70-90 Ibs. FREE FROM WEEDS
TH# H7D - 0"42" TOPSOIL
TH „D" - 0"-12".TOPSOIL AND COARSE MATTER
- 12"-34" SUBSOIL
- 12"-38" BROWN FINE SANDY LOAM WOOD CHIPS 185-275 Ibs. FREE OF COARSE MATTER
- 34"-67" MED: COMPACT COARSE TO VERY FINE SAND & SILT - 38"-90" GRAY MED. COMPACT FINE SAND AIR DRIED, TREAT WITH
MOTTLES @34"
MOTTLES @ 38" PLANTING SCHEDULE:. 121bs NITROGEN / TON
492
GROUNDWATER@50", NO LEDGE
NO GROUNDWATER, NO LEDGE
ROOTS TO 26" SEEDING DATES:
APRIL 1------- JUNE 15
AUGUST 1 ------ SEPTEMBER 15
SEED MIXTURE:
45% RED FESCUE
-� 58LF OF GEOMATRIX GST 6212
f ��'
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
�+
EXISTING GRADE @ SYSTEM - 495.0 \
�/
BOTTOM OF SYSTEM - 493.90 ��
\
496
TOP OF SYSTEM - 494.90 ���
INV. 4" TOP DISTRIBUTION -PIPE - 494.90
``�
DESIGN NOTES:
Z99
1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC
HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN.
%
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
/
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
TH#7D
/
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
AREA
S00
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
/
MLSS CALCS &DESIGN FIELD CAPACITY WILL BE REQUIRED.
/
TH#7B
/ f
f / / -502
4 BEDROOM RESIDENCE
2 BEDROOM IN-LAW/GARAGE LEACHING SYSTEM CONSTRUCTION NOTES:
�♦
SLOPE 12.0%
SLOPE 7.5 % 1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND
�
504
PERC RATE - I" IN 10 MINUTES
AVG. RECEIVING SOIL
PERC RATE - 1 " IN 6.6 MINUTES TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT
( CT FILL) PLACED
DEPTH (AVG.) 32"
AVG. RECEIVING SOIL DEPTH (AVG.) 36" AND COMPACTED IN 6" LIFTS, SELECT FILL SHALL MEET THE FOLLOWING MINIMUM
MU REQUIREMENTS:
(HF) 20 X (FF) 1.75 X (PF) 1.0 = 35.0'
(HF) 26 X (FF) 1.0 X (PF) lA = 26.0'
MLSS REQUIRED - 35.0'
A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
MLSS REQUIRED - 26.0' B. THE FILL SHALL NOT CONTAIN MORE
f
MLSS PROVIDED - 58.0'
THAN 45 PERCENT �' SIEVES)
GRAVEL (GRAVEL IS BETWEEN NO. & 3
MLSS PROVIDED - 38.0' NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE.
-�-.
4 BEDROOM HOUSE REQUIRES 577.5 S.F.
2 BEDROOM HOUSE REQUIRES 375 S.F. C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA:
OF EFFECTIVE LEACHING AREA
OF EFFECTIVE LEACHING AREA SIEVE SIZE: #4
/
USE 58 FEET OF GEOMATRIX-GST 6212 12 DEPTH
USE 38 FEET OF GEOMATRIX-GST 6212 (12" DEPTH)
{58 X 10.0 = 580 S.F.)
(38 X 10.0 = 380 S.F.) %PASSING: 100 70-100 **10-50 0-20 0-5 WET SIEVE
% PASSING: 100
USE 1,250 GAL. 2 COMPARTMENT SEPTIC TANK
70-100 10-75 0-5 0-2,5 DRY SIEVE
USE 1,00 GAL. 2 COMPARTMENT SEPTIC TANK
W/ OUTLET FILTER DEVICE
W/ OUTLET FILTER DEVICE ** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
RESERVE AREA
RESERVE AREA PASSING THE # 100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
SAME AS PRIMARY
2, DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT.
SAME AS PRIMARY
504
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA
506
AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
)POSED 1
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
ELL
SEPTIC SYSTEM CONSTRUCTION NOTES:
ho�O
1. CONSTRUCTION SEQUENCE:
. f
i
r
�.n
0
IPIN
REC.
y #flUU <J
N
ASTM C-33 SAND
CT DOT #6 STONE
•�ti
1'
w�
• t�
v.•
DISTRIBUTION PIPE
2X2 5/8 16 GA. WIRE MESH
1 1/2" 7,
NOT TO SCALE
FINISH GRADE TO
DIRECT RUNOFF AWAY
FROM SY TEM
6" MIN.
COVER
i-FILTER FABRIC
%-•CT DOT #6 STONE
ASTM C-33 SAND
CROSS SECTION A -A
FTIXER FABRIC
.._ .=. AA
=! ►!% ! �ir���
+
DOT #6 STONE
CROSSASTM C-33 SAND
Br
GEOMATRIX GST LEACHING SYSTEM
IF -1F
-I
KNOCKOUT INLET AND
n
OUTLET OPENINGS
�?
- N 11z
RIBS INSIDE IJIj�-
L Ali IL
c�U
_
N1+
LI
{ CAST
CONCRETE COVERS
PLAN
CAST
CONCRETE COVERS
CAPACITIES
A
B
C
PLAN
1250 GAL
61"
51"
48"
1500 GAL
69"
59"
Sb"
4 x 4 12.6/12.6 GA. WIRE MESH
4 x 4 12.6/12.6 GA. WIRE MESH
17 1l2" b x 6 6/6 GA. WIRE MESH
17 I/2" 6 x 6 6/6 GA. WIRE MESH
4„
INLE
\� - /"
3" VENT
3" VENT
-,, •
s 3" VENT---^
OUTLET
LIQUID LEVEL ---'OUTLET
OUTLET
LIQUID LEVEL ---'CONTINUOUS
HOT
4" OUTLET
BAFFLE
FILTER
CONTINUOUS HOT
OUTLET
ASPHALT SEAL LINED WITH
4" SCHEDULE #d0 u8" PVC
h
DEVICE
\ASPHALT SEAL
U
FILTER
DEVICE
INLET BAFFLE 60'GAS
SCHED• #40
DEFLECT
NT
i
'1
h- 3„
CROSS SECTION
SEPTIC TANK
NOT TO SCALE
1000 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
tti><ti�tttt tittlrali,f
it
x�''F
Ata
SU
� -
t''• ltatti111,1'='�'�
TO MY KNOWLEDGE AND BELIEF, THIS MAP IS SUBSTANTIALLY CORRECT
AS NOTED HEREON. THIS MAP IS NOT VALID WITHOUT A LIVE SIGNATURE
AND THE EMBOSSED SEAL OF THE SURVEYOR HEREON.
11/21/24
RICHARD A. DESCHAMPS L.S. 470019
DATE
A. J I x1r K a I VUKYILb I MOIL I,RUM LEACHING "TRENCH AREA.
B. PLACE SELECT FILL IF REQUIRED.
C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE.
D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS
WITH EROSION CONTROLS UNTIL FIRST MOWING.
2• THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D 1785 SCHD 40 OR APPROVED EQUAL.
3• ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN
STONE ON COMPACTED SUBGRADE.
5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO. 4
STONE:
SIEVE SIZE PERCENT PASSING (BY WEIGHT)
2-INCH 100
1-1/2-INCH 90-100
1-INCH 2O-55
3/4-INCH 0-10
3/8-INCH 0-5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE
FIELD BY A LICENSED LAND SURVEYOR.
8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 14" INTO EXISTING
GRADE.
NOTES:
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T 2 MAPPING
STANDARDS.
2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT.
3. BASE FOR LEVELS: N.A.V.D. 1988.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-120.
(CLUSTER SUBDIVISION)
5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6. TOTAL AREA OF PROPERTY-127,595 S.F.1 (2.93 ACRES).
7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION,
REFERENCE MAP:
SUBDIVISION PLAN ZONING DISTRICT WRP-160, R-80 & R-120, PREPARED FOR,
OXIBY FARMS, LLC, FORSYTH ROAD, OLD COLCHESTER ROAD & OXOBOXO DAM
ROAD, MONTVILLE CT, DATE:05/01/2000, SCALES: AS NOTED, ALL SHEETS,
PREPARED BY CHANDLER, PALMER & KING.