HomeMy WebLinkAboutInfinigy Mount Analysis 8-13-21INFINIGY6 August 13, 2021 Dish Wireless Site Name BOBOS00022A Dish Wireless Site Number BOBOS00022A ATC Site Name Hartford — NYC, CT ATC Site Number 302532 Infini Job Number 1197-F0001-C Client ATC Carrier Dish Wireless _ Site Location 1337 Route 85 Oakdale, CT 06370 New London County 41.417772 N NAD83 72.19810 W NAD83 Mount Type_ 8.0 It Sector Frames Mount Elevation 179.0 ft AGL Structural tJsa e Ratio 43.4 Overall Result Pass The enclosed mount structural analysis has been performed in accordance with the 2018 Connecticut State Building Code (2015 IBC) based on an ultimate 3-second gust wind speed of 135 mph. The evaluation criteria and applicable codes are presented in the next section of this report. Mount Analysis Report August 13, 2021 1. Introduction 2. Design/Analysis Parameters 3. Proposed Loading Configuration 4. Supporling Documentation 5. Results 6. Recommendations 7. Assumptions 8. Liability Waiver and Limitations 9. Calculations Report VIA Page 12 Mount Analysis Report August 13, 2021 1. INTRODUCTION Infinigy performed a structural analysis on the Dish Wireless proposed telecommunication equipment supporting Sector Frames mounted to the existing structure located at the aforementioned address. All referenced supporting documents have been obtained from the client and are assumed to be accurate and applicable to this site. The mount was analyzed using Risa-3D version 17.0.4 analysis software. 2. DESIGNIANALYSIS PARAMETERS Wind Speed 135 mph 3-Second Gust Wind Speed w/ ice 50 mph 3-Second Gust w/ 1.5" ice Code / Standard TIA-222-H Adopted Code 2018 Connecticut State Building Code 2015 IBC Risk Category II Exposure Category B Topographic Category_1 Calculated Crest Height 0 ft, Seismic Spectral Response Ss = 0,166 g / S1=0,059 Live Load Wind Speed 60 mph Man Live Load at Mid/End Points 250 Ibs Man Live Load at Mount Pipes 500 Ibs 3. PROPOSED LOADING CONFIGURATION • 179.0 ft. AGL Sector Frames Antenna Centerline ft Qty. Appurtenance Manufacturers Appurtenance Models 3 JMA WIRELESS MX08FRO665-21 3 FUJITSU TA08025-8605 179.0 3 FUJITSU TA08025-13604 1 RAYCAP RDIDC-9181-PF-48 4. SUPPORTING DOCUMENTATION Proposed Loading Dish Wireless Asset ID CT-ATC-T-302532 Rev 3, Site 4BOBOS00022A, dated April 27, 2021 Mount Manufacturer Drawin s Commsco e Document # MTC3975083, dated March 17, 2021 Structural Analysis Report American Tower Corporation, Site #302532, dated April 21, 2021 Report V1.1 Page 13 Mount Analysis Report August 13, 2021 MNMII f*1 Components Capa®— PasslFail Mount Pipes 28.7% Pass _ Horizontals 16.6% Pass Standoffs Connections 43.4% 14J% Pass Pass INOOKRATING 43.4% Pass Notes: 1. See additional documentation in Appendix for calculations supporting the capacity consumed and detailed mount connection calculations. 6. RECOMMENDATIONS Infinigy recommends installing Dish Wireless's proposed equipment loading configuration on the mount at 179.0 ft. The installation shall be performed in accordance with the construction documents issued for this site. Pradin Suinyal Magar Project Engineer II 1 INFINIGY Report v1.1 Page 14