Loading...
HomeMy WebLinkAboutNotice of Exemption Modification 11-3-2025CCCROWN Crown Castle 3 Corporate Park Drive, Suite 701 CASTLE Clifton Park, NY12065 Nov 3, 2025 Melanie A. Bachman Executive Director Connecticut Siting Council 10 Franklin Square New Britain, CT 06051 RE: Notice of Exempt Modification for Verizon Crown 4876370; Verizon Site ID 50000245192 41 Beckwith Rd, Montville, CT 06370 Latitude: 411 26'7.66" / Longitude: -721 13' 15.07" Dear Ms. Bachman: Verizon currently maintains nine (9) antennas at the 167-foot level of the existing 180-foot monopole tower at 41 Beckwith Rd, CT. The tower is owned by Crown Castle and the property is owned by Gladys J Bond Trustee. Verizon now intends to remove twelve (12) radios and install three (3) new antennas and ancillary equipment at the 167-foot level. This modification may include B2, B5, B17, B 14, B29, B30, B66 & n77 hardware that is 4G(LTE) and/or 5GNR capable through remote software configuration and either or both services may be turned on or off at various times. Planned Modification: Tower: Installed New: Mount Modification per Mount (3) SAMSUNG-MT6413-77A Antennas (3) SAMSUNG-RF4461D-13A Radios (3) SANSUNG-RF4801 D-25A Radios (3) Commseope Diplexers (1)RAYCAP-NGOVP (1) 3x6 Hybrid Cable Remove: (3) NOKIA-AHCA Radios (3) NOKIA-UHBA Radios (3) NOKIA-UHFA B25 Radios (3) NOKIA-UHIE Radios The facility was approved by the Town of Montville Planning & Zoning on May 91, 2000. The Foundation for a Wireless World. CrownCastle.com Melanie A. Bachman Page 2 Please accept this letter as notification pursuant to Regulations of Connecticut State Agencies § 16-50j-73, for construction that constitutes an exempt modification pursuant to R.C.S.A. § 16-50j-72(b)(2). In accordance with R.C.S.A. § 16-50j-73, a copy of this letter is being sent to Leonard Bunnell, Sr — Mayor, Dennis Goderre, Planning Director and property owner Gladys J Bond, Trustee. Crown Castle is the tower owner. 1. The proposed modifications will not result in an increase in the height of the existing tower. 2. The proposed modifications will not require the extension of the site boundary. 3. The proposed modification will not increase noise levels at the facility by six decibels or more, or to levels that exceed state and local criteria. 4. The operation of the replacement antennas will not increase radio frequency emissions at the facility to a level at or above the Federal Communication Commission safety standard. 5. The proposed modifications will not cause a change or alteration in the physical or environmental characteristics of the site. 6. The existing structure and its foundation can support the proposed loading. For the foregoing reasons, Verizon respectfully submits that the proposed modifications to the above - reference telecommunications facility constitutes an exempt modification under R.C.S.A. § 16-50j-72(b)(2). Please send approval/rejection letter to Attn: Jeff Barbadora. A *ado2rra Permitting Specialist 1800 W. Park Drive Westborough, MA 01581 (781) 970-0053/ Jeff.Barbadora@crowncastle.com Attachments cc: Leonard Bunnell, Sr - Mayor 310 Norwich -New London Tpke Uncasville, CT 06382 860-848-6778 Dennis Goderre, Planning Director 310 Norwich -New London Tpke Uncasvil le, CT 06382 860-848-6779 Gladys J Bond, Trustee 41 Beckwith, Rd Oakdale, CT 06370 Crown Castle, Tower Owner The Foundation for a Wireless World. CrownCastle.com LEGAL NOTICE The Montville Planning and Zoning Commission at its meeting held on, May 9, 2000, took the following action: Sprint PCSIBond: An application for a special permit for telecommunucations tower located on the property located at 41 Beckwith Road, Montville, Ct, Shown on Assessor's Map 12, Lot 1. GRANTED with CONDITIONS. Maps and documentation concerning the above applications are on file in the office of the Town Planner and Town Clerk, Town Hall Annex and Town Hall, respectively, Montville, Ct. Dated at Montville, Ct. this loth day of May, 2000. MONTVILLE PLANNING AND ZONING COMMISSION Gregory Majewski, Chairman / PUBLISH IN THE NEW LONDON DAY MAY,I; 2000 PLEASE REFERENCE PURCHASE ORDER 6100 1 1 ON INVOICE. �P 71"(y (9 -f z_ 0 �,j EEP-18-00 14,13 PRON.SROHN RUDNICK PRE£D rO.EE050H050r PAGE 2/3 510 VOL. 3 4 2 PAGE 3 91 TEL: ea FAX: 8d8-=4-2354 TOWN OF MONTYMLE PL.OMG & ZONING COMMISSION 310NORW*H-NEWLONDONTP*— UN0ASVILLE, CONNEffMIP0M-?6" CERTIFICATE OF NOTICE OF DECISION APPROVAL: APPROVED WICONDITIONS LOCATIONMESCRIPTION: 41 BECKWITH ROAD NATURE OF PROJECT: TELECOMk1UMCATIONS TOWER APPLICABLE ZONING REGULATION: REGULATION OWNER OF REOORO: SPRINT PCSIBOND 147 Recow forRecord SEP 0. 6 2000 At h m �, M. snd recorded 6y UEP-I8-00 14-49 FROM�SRONN RUDNICK FREED I D�HH060HHfi01 PAGE 3/3 AFTkR RECOXWXNCr, PLEASE RE, M TO: Thomas J. Regan, Esquire Brown Rudnick Freed & Qesmer 185 Asylum Street, 3P Floor Hartford, CT 06M-3402 Pq m c� IN i W c W o n o m o E ,�$ ccoo 0 O O- co L (0 V) N p Z O i i �% N N 4' O N O co U V) C W U Q O) (L6 ca O m N 3 Q zoo O 0 c �� N O 10 Of 1 4 m E r E D_ F co m 2 (a it a` E d O N O) m ¢ >° in C v in E O 00 c d d 3 E w @c Q O tL o - Z 2 Q Q C U N (a m O oo (n a) ca a)_ N O @ CN Q. N d 0)N 00 00 Q' N O > to IL 2 LL U LL 00 Ix O ` d W (a H O O N O O Q a d N 0) (o 7 � (O 00 V T O A J Q N (O c0 E _ LL > N m 0 c p p LO w m •_• a O O N @ (n r+ (o Q' N U (n (n V E /W W W N m N w L @ m F 0 3 d o Z = 0 0� O W CA(D p Q N @ N C V Q (O N M } U 7 U o U w an v 4, m v O s. �+ rn � F� v 3 t O N v T v m 0 D J m 0 H A N M N In n w LO N N lii O LO n n L'1 L� / Date: September 15, 2025 Subject: Carrier Designation: Crown Castle Designation: Engineering Firm Designation: Site Data: Structural Analysis Report Verizon Wireless Co -Locate Site Number: Site Name: BU Number: Site Name: JDE Job Number: Work Order Number: Order Number: Project Number: B-07' GRP MTS Engineering, P.L.L.0 1717 S. Boulder, Suite 300 Tulsa, OK 74119 (918)587-4630 5000245192 CHESTERFIELD CT 876370 MAYBROOK/BOND 2160151 2427027 716806 Rev. 1 25-006701 41 Beckwith Rd., Montville, New London County, CT Latitude 41 ° 26' 7.66", Longitude -720 13' 15.07" 180 Foot - Monopole 'We are pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above - mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 125 mph as required by the 2022 Connecticut State Building Code. Applicable standard references and design criteria are listed in Section 2 - Analysis Criteria. Structural analysis prepared by: Anthony Ruppert Respectfully submitted by: MTS Engineering, P.L.L.C. COA: PEC.0001564; y it PSo.73924 s 101d L Chad E. Tuttle, P.E. tnxTower Report - version 8.3.1.2 180 Ft Monopole Structural Analysis September 15, 2025 Project Number 25-006701, Order 716806, Revision 1 CC/ BU No 876370 Page 3 1) INTRODUCTION This is a 180 ft. Monopole designed by Engineered Endeavors, Inc. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: 11 Wind Speed: 125 mph Exposure Category: B Topographic Factor: 1 Ice Thickness: 1 in Wind Speed with Ice: 50 mph Service Wind Speed: 60 mph Table 1 -Proposed Equipment Configuration Center Number Line Antenna Number Feed LLevel Elevation °f Antennas Manufacturer Antenna Model of Feed Line (ft) Lines Size (in) 1 j Platform Mount [LP 303- 167.0 1_KCKR HR-11 3 Antel LPA-80080/4CF 3 Commscope C13C78T-DS-43-2X 167.0 6 j Commscope i JAHH-65B-R36 12 1-5/8 165.0 � 1 Raycap -_ RCMDC-8627-PF48 �I 3 Samsung Telecom. MT6413-77A 3 ;Samsung Telecom. RF4461D-13A 3 iSamsung Telecom. j RF4801d-25A ti. 0 1 Lucent KS24019-L112A _ - -- 75 0 1 — Side Arm Mount [SO 701-1] _ 1 1/2 Table 2 - Other Considered Equipment Mounting Number Antenna Number Feed Level (ft)Antennas of F Manufacturer Antenna Model of Feed Line Lines Size (in) 181.0 3 Commscope 1 NNW-65B-R4 j 3 Alcatel Lucent 1 PCS 1900MHZ 4X45W-65MHZ 179.0 180.0 ; 6 Alcatel Lucent RRH2X50-800 3 Nokia FZHN 4 1-1/4 3 Rfs Celwave APXVTM14-ALU-120 179.0 1 -- - Platform Mount [LP 303-11 - r1 Commscope W-65A-R1 TMO - 2 Ericsson AIR 6419 B41 TMO 174.0 3 Ericsson RADIO 4449 B71 B85A T- 174.0 _ _ MOBILE 3 Ericsson RADIO 4460 B2/B25 B66 TMO 4 1-5/8 1 I Platform Mount [LP 303- i 1_KCKR-HR-1] 1 173.0 1 2 Commscope W-65A-RI_TMO tnxTower Report - version 8.3.1.2 I September 15, 2025 180 Ft Monopole Structural Analysis CCI BU No 876370 Project Number 25-006701, Order716806, Revision 1 Page 4 a Center Number Mounting Line of Level (ft) Elevation IA-f- - -,. 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Antenna Manufacturer Ericsson Rfs Celwave Antenna Model AIR 6419 B41 TMO APXVAARR18_43-U-NA20 Number ISize(in) Feed ofFeed Line Lines Document I Reference I Source Tower Manufacturer Drawing 1532099 CCI Sites Foundation Drawing 2122781 CCI Sites Geotech Report ( 1533478 i CCI Sites Crown CAD Package Date: 09/10/2025 CCI Sites 3.1) Analysis Method tnxTower (version 8.3.1.2), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 standard. 3.2) Assumptions 1) The tower and structures were maintained in accordance with the - TIA-222 standard. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. We should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) ISaction� No. Elevation (ft) I Component ( Type Size ICritical l Element P (� (SF'P allow (K))Capacity Pass I Fail Lt 180 - 133 Pole I TP27.51x15.5x0.25 1 -14.055 ' 1278.858 56.4 Pass L2 133- 87.33 Pole TP38.56x25.988x0.375 2 -22.865 2693.113 45.9 Pass L3 �87.33-42.66 Pole TP49.1x36.461x0.438 ( 3 -35.827 4006.915 42.0 Pass L4 42.66 - 0 . ,I. Pole TP59x46.5390.438 4 -54.285 4995.165 45.0 Pass I Summary) Pole (1-1)� 56.4 Pass - F _ Rating - 56.4 Pass tnxTower Report - version 8.3.1.2 0 180 Ft Monopole Structural Analysis Project Number 25-006701, Order 716806, Revision 1 Table 5 - Tower Component Stresses vs. Capacity — LC5 September 15, 2025 CCI BU No 676370 Page 5 Notes I Component I Elevation (ft) ' % Capacity Pass / Fail 1,2 Anchor Rods Base 40.7 Pass ---------- Base Plate Base 56.6 Pass j 1,2,3 Base Foundation Base 46.5 Pass Structure Rating (max from all components) = 56.6% Notes: 1) See additional documentation in 'Appendix C —Additional Calculations" for calculations supporting the % capacity consumed. 2) Rating per TIA-222-H Section 15.5. 3) Foundation capacity determined by comparing analysis reactions to original design reactions. 4.1) Recommendations The tower and its foundations have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report- version 8.3.1.2 x7le zion Engineering & Design Colliers Engineering & Design Architecture, Landscape Architecture, Surveying CT, P.C. 2000 Midlantic Drive, Suite 100 Mt. Laurel, NJ 08054 856.797.0412 sean.osullivan@collierseng.com Antenna Mount Analysis Report and PMI Requirements Mount ReAnalysis-VZW SMART Tool Project #: 10317667 Colliers Engineering & Design Project #: 21777310A (Rev. 1) August 19, 2025 Site Information Site ID: 5000245192-VZW/CHESTERFIELD CT Site Name: CHESTERFIELD CT Carrier Name: Verizon Wireless Address: 41 Beckwith Rd. Oakdale, Connecticut 06370 New London County Latitude: 41.435472' Longitude: -72.2208330 Structure Information Tower Type: 180-Ft Monopole Mount Type: 12.50-Ft Platform 11YANIOX31[: #6111Big Analysis Results Platform: 46.5% Pass* *Antennas and equipment to be installed in compliance with PMI Requirements of this mount analysis. ***ContractorPMl Requirements: Included at the end of this MA report Available & Submitted via portal at https:llpmi.vzvvsmart.com For additional questions and support, please reach out to: pmisupport@colliersengineering. com Gg.:' i'" er Gram \'lacers Report Prepared By: Dan Palmadessa Dee 20250a 2009272M5W Y, ,, � Z,, 7 Mount Structural Analysis Report August 19, 2025 (1) 12.50-Ft Platform Site ID: 5000245192-VZW/CHESTERFIELD CT Page (2 Executive Summary: The objective of this report is to determine the capacity of the antenna support mount at the subject facility for the final wireless telecommunications configuration, per the applicable codes and standards. Any modification listed under Sources of Information was assumed completed and was included in this analysis. This analysis is inclusive of the mount structure only and does not address the structural capacity of the supporting structure. This mounting frame was not analyzed as an anchor attachment point for fall protection. All climbing activities are required to have a fall protection plan completed by a competent person. Sources of Information: Analysis Criteria: Codes and Standards: ANSI/TIA-222-H 2022 Connecticut State Building Code (CSBC), Effective October 1, 2022 Wind Parameters: Basic Wind Speed (Ultimate 3-sec. Gust), VuLT: Ice Wind Speed (3-sec. Gust): Design Ice Thickness: Risk Category: Exposure Category: Topographic Category: Topographic Feature Considered: Topographic Method: Ground Elevation Factor, Ke: Seismic Parameters: Maintenance Parameters: Ss: Si: Wind Speed (3-sec. Gust): Maintenance Load, Lv: Maintenance Load, Lm: Analysis Software: RISA-31D (V22) 125 mph 50 mph 1.00 in B 1 N/A N/A 0.991 0.201 g 0.054 g 30 mph 250 lbs. 500 lbs. Mount Structural Analysis Report August 19, 2025 (1) 12.50-Ft Platform Site ID: 5000245192-VZW/CHESTERFIELD CT Page13 Final Loadinq Confiauration: The following equipment has been considered for the analysis of the mount 166.50 1 167:00 Commscope CBC78T-DS-43 Added 3 Samsung RF4801d-25A 6 1 Commscope I JAHH-65B-R3B 3 1 AmphenolAntel f LPA-80080-4CF-EDIN-6 Retained It is acceptable to install up to three (3) OVPs with dimensions not to exceed 30" x 17" x 13" and 40 lbs. at any location, other than the mount face, without affecting the structural capacity of the mount. If OVP units are installed on the mount face, a mount re -analysis may be required unless replacing an existing OVP. Standard Conditions: 1. All engineering services are performed on the basis that the information provided to Colliers Engineering & Design and used in this analysis is current and correct. The existing equipment loading has been applied at locations determined from the supplied documentation. Any deviation from the loading locations specified in this report shall be communicated to Colliers Engineering & Design to verify deviation will not adversely impact the analysis. 2. Mounts are assumed to have been properly fabricated, installed and maintained in good condition, twist free and plumb in accordance with its original design and manufacturer's specifications. Obvious safety and structural issues/deficiencies noticed at the time of the mount mapping and reported in the Mount Mapping Report are assumed to be corrected and documented as part of the PMI process and are not considered in the mount analysis. The mount analysis and the mount mapping are not a condition assessment of the mount. Proper maintenance and condition assessments are still required post analysis. 3. For mount analyses completed from other data sources (including new replacement mounts) and not specifically mapped in accordance with the NSTDA46 Standard, the mounts are assumed to have been properly fabricated, installed and maintained in good condition, twist free and plumb in accordance with its original design and manufacturer's specifications. 4. All member connections are assumed to have been designed to meet or exceed the load carrying capacity of the connected member unless otherwise specified in this report. 5. The mount was checked up to, and including, the bolts that fasten it to the mount collar/attachment and threaded rod connections in collar members if applicable. Local deformation and interaction between the mount collar/attachment and the supporting tower structure are outside the scope of this analysis. 6. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. Colliers Engineering & Design is not responsible for the conclusion, opinions, and recommendations made by others based on the information supplied. Mount Structural Analysis Report (1) 12.50-Ft Platform August 19, 2025 Site ID: 5000245192-VZW/CHESTERFIELD CT Page 14 Structural Steel Grades have been assumed as follows, if applicable, unless otherwise noted in this analysis: o Channel, Solid Round, Angle, Plate ASTM A36 (Gr. 36) o HSS (Rectangular) ASTM 500 (Gr. B-46) o Pipe ASTM A53 (Gr. B-35) o Threaded Rod F1554 (Gr. 36) o Bolts ASTM A325 Discrepancies between in -field conditions and the assumptions listed above may render this analysis invalid unless explicitly approved by Colliers Engineering & Design. Analysis Results: Dtd¢atron % t'asslFad Face Horizontal 16.1 % Pass Standoff Horizontal 13.9 % Pass Platform Crossmember 10.7 % Pass Corner Plate 31.9 %. Pass Grating Support 16.3 % Pass Cross Arm Plate 23.7 % Pass Support Rail Corner 6.5 % Pass Kicker 8.7 % Pass Support Rail 19.0 % Pass Mount Pipe 46.5 % Pass Mount Connection 18.6 % Pass Mount Structural Analysis Report (1) 12.50-Ft Platform Mount Connection Envelope Reactions: August 19, 2025 Site ID: 5000245192-VZW/CHESTERFIELD CT Page15 Boa t Erfvelope WindReacUons Emefope Y1rmd IceRea�Figns Coo ���-��- AiaL Node AziaT Lateral Moment Tors�od Axral 'Lateral Moment Torsion'. Sector B 166.5 N3 545 4356 0.356 1.732 509 2870 0.527 0.399 Standoff Sector 166.5 N87D 321 3547 0.358 1.233 216 2582 0.460 0.308 Standoff Sector C 166.5 N115 246 3998 0.271 2.073 127 3235 0.120 0.452 Standoff Sector B 163.8 N113B 1641 1924 0.000 0.000 2154 2531 0.000 0.000 Reinforcement Sector 163.8 N115A 1485 1736 0.000 0.000 2026 2378 0.000 0.000 Reinforcement Sector 163.8 N117A 1696 1989 0.000 0.000 2545 2999 0.000 0.000 Reinforcement Notes: - Axial loads act along the axis of the tower - Lateral reactions act perpendicular to the tower - Moment loads introduce bending moment to the tower - Torsion loads introduce twisting moment to the tower - Batch solutions by individual load cases are included at the end of this document Mount Steel (EPA)a per ANSI/TIA-222-H Section 2.6.11.2: �M ' -t 7VfottnLPtpes F�cctaded IVlount Prpes (nciaded T►rontEPA)a Side{EPA}a 1 ront(EPA)a S�def;EPAja '..;- 0 27.6 27.6 44.7 44.7 0.5 36.4 36.4 60.7 60.7 1 44.4 44.4 75.9 75.9 Notes: - (EPA)a values listed above may be used in the absence of more precise information - (EPA)a values in the table above include 3 sector(s). - Ka factors included in (EPA)a calculations Requirements: The existing mount is SUFFICIENT for the final loading configuration shown in attachment 2 and do not require modifications. Additional requirements are noted below. N/A If required, ANSI/ASSP rigging plan review services compliant with the requirements ofANSI/TIA 322 are available for a Construction Class IV site or other. Separate review fees will apply. *' FOX HILL TELECOM Radio Frequency Emissions Analysis Report Prepared for: CROWN CASTLE verizon' Crown Site ID: 876370_Maybrook / Bond Verizon Wireless Site Name: Chesterfield CT Verizon Wireless FUZE ID: 16272130 Site Address: 41 Beckwith Road Montville, CT 06370 October 16, 2025 Fox Hill Telecom Project Number: 250350 1# FOX HILL TELECOM General population exposure to radio frequencies is regulated and enforced in units of microwatts per square centimeter (VW/cm 2). The general population exposure limits for the 700 MHz band & the 850 MHz cellular band are approximately 497 µW/cm2 and 586 µW/cm2 respectively. The general population exposure limit for the 1900 MHz (PCS), 2100 MHz (AWS) and 3700 MHz (C band) frequency bands is 1000 µW/c1112. Because each carrier will be using different frequency bands, and each frequency band has different exposure limits, it is necessary to report the percentage of MPE rather than power density. Occupational/controlled exposure limits apply to situations in which people are exposed as a consequence of their employment and in which those people who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general population/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Additional details can be found in FCC OFT 65. Fox Hill Telecom, Inc Worcester MA 01609 FOX HILL TELECOM For each Verizon Wireless sector, the following channel counts, frequency bands and power levels were utilized as shown in Table 1: Technology Frequency Band Channel Count Transmit Power per Channel LTE 700 MHz 4 40 LTE / 5G 850 MHz 4 40 LTE 1900 MHz PCS 4 80 LTE 2100 MHz AWS 4 80 5G 3700 MHz C Band 2 I60 Table 1: Channel Data Table Fox Hill Telecom, Inc Worcester MA 01609 1# FOX HILL TELECOM RESULTS Per the calculations completed for the proposed Verizon Wireless configurations Table 3 shows resulting emissions power levels and percentages of the FCC's allowable general population limit. Total TX Antenna Antenna Make / Antenna Gain Channel Pomvr ID Model Frequency Bands dBd Count ERP NVE % Antenna Commscope At JAHH-65B-R3B 700 MHz / 850 MHz 12.35 / 13.65 8 320 6,456.48 0.23 Antenna Commscope 1900 MHz (PCS) / 2100 A2 JAI- H-65B-R3B MHz AWS 16.25 / 16.35 8 640 27 302.90 0.25 Antenna Samsung A3 MT6413-77A 3700 MHz C Band 23.15 2 320 1 66 092.16 0.94 Antel Antenna LPA-80080-4CF A4 Dormant NA 0 0 0 0.00 0.00 Sector A C mposite MPE% 1.42 Antenna Commscope B 1 JAHH-65B-R3B 700 MHz / 850 MHz 12.35 / 13.65 8 320 6,456.48 0.00 Antenna Commscope 1900 MHz (PCS) / 2100 B2 JAHH-65B-R3B MHz AWS 16.25116.35 8 640 27,302.90 0.00 Antenna Samsung B3 MT6413.77A 3700 MHz C Band 23.15 2 320 66 092.16 0.00 Antel Antenna LPA-80080-4CF B4 Dormant NA 0 0 0 0.00 0.00 Sector B C mposite NIPE% 0.00 Antenna Commscope CI JAHH-65B-R3B 700 MHz / 850 MHz 12.35 / 13.65 8 320 6,456.48 0.00 Antenna Commscope 1900 MHz (PCS) / 2100 C2 JAHH-65B-R3B MHz AWS 16.25/16.35 8 640 27,302.90 0.00 Antenna Samsung C3 MT6413.77A 3700 MHz C Band 23.15 2 320 66,092.16 0.00 Antel Antenna LPA-80080-4CF C4 Dormant NA 0 0 0 0.00 0.00 Sector C Composite MPE% 0.00 Table 3: Verizon li'ireless hwentory and Power Data table Fox Hill Telecom, Inc Worcester MA 01609 FOX HILL TELECOM Table 6 below details a breakdown by frequency band and technology for the MPE power values for the maximum calculated Verizon sector(s). For this site, all three Verizon Wireless sectors have the same configuration, yielding the same results for all three sectors. Verizon Wireless _ Frequency Band / Technology Max Power Values (Per Sector # Channels(Per Watts ERP Channel Height feet Total Power Density W/cm) Frequency (.1f1z Allowable MPE W/cm' Calculated %AtPE Verizon Wireless 700 MHz LTE 4 687.16 165 0.60 700 NR4z 497 0.12% Verizon Wireless 850 blHz LTE / 5G 4 926.96 165 0.64 850 b114z 586 0.11% Verizon Wireless 1900 blHz CS LTE 4 3,373.57 165 1.20 1900 MHz CS 1000 0.12% Verizon Wireless 2100 MHz AWS LTE 4 3452.15 165 1.30 2100 MHz AWS 1000 0. M/. Verizon Wireless 3700 MHz C Band 5G 2 33 046.08 165 9.40 3700 btHz C Band 1000 0.94% Total: 1.42 % Table 6: Verizon R'ireless b/arintunt Sector APE Power Values Fox Hill Telecom, Inc Worcester MA 01609