HomeMy WebLinkAbout25 SUB 2 SITE PLANS 3-28-25LAKEE
A
S
T
FIRE
Bro
o
k
Bro
o
k
Hunts
SITE
ST
R
E
E
THallowDeep
FIR
E
ST
R
E
E
T
ROA
D
OHEOHEOH
E
OH
E
OHE
OHE OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE OHE OHE OHE
AT&T
2638
FRNT
2640SNET
2640
AT&T
2647
SNET
2648SNET
2650S CB Type "Dbl"
TF=230.44
CB Type "CL"
TF=179.59
Inv 15" CMP=175.58
Inv 24" RCP=141.04
Inv 24" RCP=138.67
Inv 18" CMP=140.42
W
W W
W
W
W
W
W
Existing CB Type "CL"
TF=265.12
Inv 2x2 Culvert=262.32
Existing CB Type "CL"
TF=264.96
Inv 2x2 Culvert=261.66
Inv 18" CMP=141.38
Inv 18" CMP=137.01
Inv 18" CMP=144.96
SNET
2637
SNET
2641
FRNT
2642
SNET
2643
FRNT
2644
SNET
2646
SNET
2649
SNET
2650
SNET
2651
APPROVED DRAINAGE EASEMENT
AND RIGHTS TO DRAIN IN FAVOROF THE TOWN OF MONTVILLE
N/F
Donald G. Concascia
Shelly C. Concascia
Volume 297, Page 288
N/F
Gordon M. Levy
Volume 656, Page 996
N/F
Mark C. Thornton
Joanna Thornton
Volume 576, Page 744
APPROVED 12' WIDE TRAFFIC BOUND
GRAVEL SURFACE OR PAVED DRIVEWAY
WITH A MAXIMUM SLOPE OF 8% (TYP.)
N/F
Patrick & Jessica
O'Brien
Volume 679, Page 88
N/F
City of New London
Volume 241, Page 33
N/F
The Connecticut
Audubon Society, Inc.
Volume 659, Page 652
N/F
Gary David Senecal, Jr.
Lori B. Senecal
Volume 667, Page 490
N/F
Juan M. Duran, Jr.
Yira A. Colon
Volume 677, Page 104
N/F
Joel & Brittany
Burchwell
Volume 672, Page 977
N/F
Sunmar/RAF Builders,
LLC
Volume 667, Page 927
N/F
Sunmar/RAF
Builders, LLC
Volume 667, Page 927
N/F
City of New London
Volume 223, Page 714
AT&T
2636
APPROVED 24" HDPE FLARED
END SECTION WITH TYPE 1
PRE-FORMED SCOUR HOLE
INV = 260.00
APPROVED LOT 8
(1125 EAST LAKE ROAD)
(I.D. 007/035/008)
APPROVED LOT 7
(1121 EAST LAKE ROAD)
(I.D. 007/035/007)
APPROVED LOT 6
(1117 EAST LAKE ROAD)
(I.D. 007/035/006)
APPROVED LOT 5
(1113 EAST LAKE ROAD)
(I.D. 007/035/005)
APPROVED LOT 4
(1109 EAST LAKE ROAD)
(I.D. 007/035/004)
APPROVED LOT 3
(1105 EAST LAKE ROAD)
(I.D. 007/035/003)
APPROVED LOT 2
(1099 EAST LAKE ROAD)
(I.D. 007/035/002)
APPROVED LOT 1
(1093 EAST LAKE ROAD)
(I.D. 007/035/001)
N/F
Estate of Jerry G. Sweezy
Volume 32, Page 196
320
318316
322
322
322
3203203183
2
4
3
2
2
3
2
0 318318
316
314302304306308 310312312
314
316294296280282286284
288290292266
268260258256
25225
4256 25626
0 2622
6
0
26
2
2
5
0
2
5
2
250252238244 APPROVED
CONCEPTUAL
RESIDENCE
APPROVEDCONCEPTUAL
CLEARING LIMITS
APPROVED
CONCEPTUAL
GRADING
APPROVED 24" HDPE FLARED
END SECTION WITH TYPE 1
PRE-FORMED SCOUR HOLE
INV=248.00
APPROVED 200' L.F.
24" HDPE DRAIN
S= 0.060 FT./FT.250190200210220230240266260250240230220210200190180170160150144 160146150170180190
200
210220230240250260270280290300310320322
324
326320 314310 310300 290248252 2501
8
0
190
200210220230CB Type "CL"
TF=230.54 24025
0
2
6
0
270
28
0
290
30
0
3
1
0 320320
314
318
314
258ENSW100050
SCALE IN FEET
100PRE-EXISTING PROPERTY LINE
APPROVED EASEMENT
OHEOVERHEAD ELECTRIC
STORM PIPE
WETLAND
APPROVED TREELINE
STONEWALL
EX. INDEX CONTOUR
EX. INT. CONTOUR
300
298
ADJOINER PROPERTY LINE
LEGEND
APPROVED LOT LINE
PR. INDEX CONTOUR
PR. INT. CONTOUR
300
298
UTILITY POLE
1"=1,000'
LOCATION MAP
29798No.
M.M
AR
O
NSAM
EU S
LICE N S E DRPFOS
E
ISONA L NE IG ENS ERSTATEO F C ONNE
C
T
CI
UTDESCRIPTION OF REVISIONDRAWING
SHEET NUMBER:OF
CHECKED BY:DATE:
DRAWN BY:DATE:
PROJECT NO.SCALE:DATEAPPR.REV.H HENGINEERINGASSOCIATES
232 Greenmanville Ave.
Suite 201
Mystic, CT 06355
860-980-8008
www.hh-engineers.com
PREPARED FOR:PROPERTY ADDRESS:APPROVED SUBDIVISION PLANSUBDIVISION MODIFICATIONEAST LAKE ROAD & FIRE STREET, MONTVILLE, CT 06370SUNMAR/RAF BUILDERS, LLC285 OLD COLCHESTER ROAD, UNCASVILLE, CT 063822024-0177 1" = 100'
SMM 3/28/2025
SMM 3/28/2025
ASP-1
1 3
Z:\SHARED\H+H ENGINEERING ASSOCIATES\PROJECTS\2024\2024-0177 - RICK FRANKLIN - 1121 EAST LAKE RD, OAKDALE\DWGS\APPROVED SUBDIVISION.DWG Tab: APPROVED SUBDIVISION PLAN Saved: 3/28/2025 12:10 AM Plotted: 3/28/2025 10:14 AMPR. SPOT GRADE 10.5
APPROVED INDEX CONTOUR
APPROVED INT. CONTOUR
300
298
CONSTRUCTION NOTES:
1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT
800-922-4455 TO MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3
BUSINESS DAYS PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY.
CONTRACTOR SHALL VERIFY ALL LOCATIONS, DIMENSIONS AND ELEVATIONS
OF ALL UTILITIES PRIOR TO CONSTRUCTION.
2.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE
PROPERTY SHALL BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED
PRIOR TO CONSTRUCTION.
3.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO
CONSTRUCTION. PRIOR TO ANY WORK WITHIN THE RIGHT-OF-WAY, THE
CONTRACTOR SHALL OBTAIN AN EXCAVATION AND DRAINAGE CONNECTION
PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS TO CONNECT THE NEW
DRAINAGE PIPE INTO THE CATCH BASIN IN EAST MAIN STREET.
4.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL
REQUIREMENTS AND ANY CONDITIONS OF APPROVAL OF THE TOWN OF
MONTVILLE.
5.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE
STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT
OF PUBLIC WORKS.
REFERENCE INFORMATION:
1.THIS PLAN WAS COMPILED USING THE FOLLOWING REFERENCE
INFORMATION:
A.A PLAN SET ENTITLED, "SUBDIVISION PLAN, PREPARED FOR
SUNMAR/RAF BUILDERS, LLC, PROPERTY OF WALTER N. WAINWRIGHT,
JR. EAST LAKE ROAD & FIRE STREET, MONTVILLE (OAKDALE),
CONNECTICUT," DATED JUNE 2022, LAST REVISED JULY 11, 2022,
PREPARED BY BOUNDARIES, LLC.
GENERAL NOTES:
1.THE APPLICANT AND PROPERTY OWNER IS SUNMAR/RAF BUILDERS, LLC
WITH A MAILING ADDRESS OF 285 OLD COLCHESTER ROAD, UNCASVILLE, CT
06382.
2.ON JULY 26, 2022, THE TOWN OF MONTVILLE PLANNING & ZONING
COMMISSION APPROVED SUBDIVISION APPLICATION #22SUB3 FOR A NEW
8-LOT SUBDIVISION. PER THE APPROVED PLANS, A DRAINAGE PIPE WAS
PROPOSED ALONG THE EASTERN SIDE OF LOT 7 TO CONVEY ROADWAY
RUNOFF TO THE BACK OF THE PROPERTY. DUE TO SITE CONSTRAINTS, THE
APPLICANT IS PROPOSING TO RELOCATE THE DRAINAGE PIPE TO CONVEY
STORMWATER TO THE WEST SIDE OF THE PROPERTY TO DISCHARGE TO A
RIPRAP APRON AND VEGETATED SWALE.
3.LOT 7 HAS A MAILING ADDRESS OF 1121 EAST LAKE ROAD AND IS IDENTIFIED
AS LOT 35-7 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 7. THE
DEED REFERENCE OF THE PROPERTY IS VOLUME 700 PAGE 241.
4.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE
PLANNING & ZONING COMMISSION FOR A SUBDIVISION MODIFICATION.
5.ELEVATIONS SHOWN HEREON ARE BASED ON APPROXIMATE NAVD-88
DATUM PER REFERENCE MAP 'A'.
2682662
6
4
262
260
258
256
254
252
250
248 246
256254 252 2
50
2
48
2
46 2442322
26 22422221621420219419223
8 236234228218212208206204198 1961881862702
40 230220210200190242OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE2
5
2
254
256
260
262260
262
252
2502
5
2
258
2
5
2
2
5
0
248PREVIOUSLY
APPROVED
4-BEDROOM
RESIDENCE
NEW FFE=258.30
NEW GAR.=256.30
NEW BSMT=250.30
SAN
SAN
SAN
SAN
NEW DRAINAGE
MANHOLE (DMH-1)
TF=265.50
24" INV IN=261.00
24" INV OUT=257.50
NEW FLARED END
SECTION (FES-1)
WITH RIPRAP APRON
INV=255.80
D
75' PR
O
T
E
C
TI
V
E
WELL
R
A
DI
U
S
W
NEW 9 L.F. 24" HDPE PIPE
S=0.0722 FT./FT.
NEW 24" INV OUT=261.65
2
60
NEW 118 L.F.
24" HDPE PIPE
S=0.0144 FT./FT.
262
256
2
6
4
PVMT=260.5
24" CROWN=258.4
24" INV=256.3
NEW 205 L.F. 6'(W) VEGETATED
SWALE WITH STONE CHECK
DAMS EVERY 50 L.F.
S=0.0283 FT./FT.)252251250260256APPROVED LOT 7
(1121 EAST LAKE ROAD)
(I.D. 007/035/007)
APPROVED LOT 6
(1117 EAST LAKE ROAD)
(I.D. 007/035/006)
APPROVED LOT 8
(1125 EAST LAKE ROAD)
(I.D. 007/035/008)
PREVIOUSLY APPROVED 24" HDPE
DRAINAGE PIPE (NO LONGER PROPOSED)
PREVIOUSLY APPROVED DRAINAGE EASEMENT
IN FAVOR OF THE TOWN OF MONTVILLE OVER
1121 EAST LAKE ROAD (VOL. 693 PG. 69-71)
TO BE EXTINGUISHED
PREVIOUSLY APPROVED 24" HDPE
FLARED END SECTION AND
PRE-FORMED SCOUR HOLE
(NO LONGER PROPOSED)
EXISTING CB TYPE "CL"
TF=264.96
INV 2X2 CULVERT=261.66
EXISTING CB TYPE "CL"
TF=265.12
INV 2X2 CULVERT=262.33
SNET
2646
W
PREVIOUSLY APPROVED 24" HDPE
FLARED END SECTION AND
PRE-FORMED SCOUR HOLE
(NO LONGER PROPOSED)75' PROTE
CTI
V
E
WELL
R
A
DI
US
PREVIOUSLY APPROVED
SEPTIC SYSTEM
SF
SFSFTEMPORARY SILT FENCE
PVMT=260.7
24" CROWN=258.6
24" INV=256.5
NEW DRAINAGE EASEMENT AND
RIGHTS TO DRAIN TO BE GRANTED
IN FAVOR OF THE TOWN OF MONTVILLE
AREA=4,379± SQ. FT. (0.10± AC.)
252
256257258
259 2532
5
4
255255 253
254
20.0'(W) CENTERED ON
NEW VEGETATED SWALE
N23°31'34"E
175.84'S66°28'26
"E20.00
'
S23°31'34"W
151.92'S15°27'23"E27.91'S54°26'21"E49.35'S35°33'39"W
10.00'N54°26'21"W85.62'258
260
266 ENSW20010
SCALE IN FEET
20
29798No.
M.M
AR
O
NSAM
EU S
LICE N S E DRPFOS
E
ISONA L NE IG ENS ERSTATEO F C ONNE
C
T
CI
UTDESCRIPTION OF REVISIONDRAWING
SHEET NUMBER:OF
CHECKED BY:DATE:
DRAWN BY:DATE:
PROJECT NO.SCALE:DATEAPPR.REV.H HENGINEERINGASSOCIATES
232 Greenmanville Ave.
Suite 201
Mystic, CT 06355
860-980-8008
www.hh-engineers.com
PREPARED FOR:PROPERTY ADDRESS:LOT 7 DRAINAGE MODIFICATIONSSUBDIVISION MODIFICATIONEAST LAKE ROAD & FIRE STREET, MONTVILLE, CT 06370SUNMAR/RAF BUILDERS, LLC285 OLD COLCHESTER ROAD, UNCASVILLE, CT 063822024-0177 1" = 20'
SMM 3/28/2025
SMM 3/28/2025
DM-1
2 3
Z:\SHARED\H+H ENGINEERING ASSOCIATES\PROJECTS\2024\2024-0177 - RICK FRANKLIN - 1121 EAST LAKE RD, OAKDALE\DWGS\SITE PLAN.DWG Tab: DRAINAGE MODS Saved: 3/28/2025 10:13 AM Plotted: 3/28/2025 10:14 AMCONSTRUCTION NOTES:
1.THE CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" AT 800-922-4455 TO
MARK OUT ALL UNDERGROUND UTILITIES A MINIMUM OF 3 BUSINESS DAYS PRIOR TO
COMMENCING ANY CONSTRUCTION ACTIVITY. CONTRACTOR SHALL VERIFY ALL
LOCATIONS, DIMENSIONS AND ELEVATIONS OF ALL UTILITIES PRIOR TO
CONSTRUCTION.
2.ALL PROPERTY LINES SHALL BE VERIFIED IN THE FIELD. NO PRIVATE PROPERTY SHALL
BE DISTURBED UNLESS PROPER RIGHTS ARE OBTAINED PRIOR TO CONSTRUCTION.
3.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO CONSTRUCTION.
PRIOR TO ANY WORK WITHIN THE RIGHT-OF-WAY, THE CONTRACTOR SHALL OBTAIN
AN EXCAVATION AND DRAINAGE CONNECTION PERMIT FROM THE DEPARTMENT OF
PUBLIC WORKS TO CONNECT THE NEW DRAINAGE PIPE INTO THE CATCH BASIN IN
EAST MAIN STREET.
4.THE CONTRACTOR SHALL OBTAIN, REVIEW AND ADHERE TO ALL REQUIREMENTS AND
ANY CONDITIONS OF APPROVAL OF THE TOWN OF MONTVILLE.
5.THE CONTRACTOR SHALL ADHERE TO ALL APPLICABLE TOWN OF MONTVILLE
STANDARDS, REGULATIONS, POLICIES AND PRACTICES OF THE DEPARTMENT OF
PUBLIC WORKS.
GENERAL NOTES:
1.THE APPLICANT AND PROPERTY OWNER IS SUNMAR/RAF BUILDERS, LLC WITH A
MAILING ADDRESS OF 285 OLD COLCHESTER ROAD, UNCASVILLE, CT 06382.
2.ON JULY 26, 2022, THE TOWN OF MONTVILLE PLANNING & ZONING COMMISSION
APPROVED SUBDIVISION APPLICATION #22SUB3 FOR A NEW 8-LOT SUBDIVISION. PER
THE APPROVED PLANS, A DRAINAGE PIPE WAS PROPOSED ALONG THE EASTERN SIDE
OF LOT 7 TO CONVEY ROADWAY RUNOFF TO THE BACK OF THE PROPERTY. DUE TO
SITE CONSTRAINTS, THE APPLICANT IS PROPOSING TO RELOCATE THE DRAINAGE
PIPE TO CONVEY STORMWATER TO THE WEST SIDE OF THE PROPERTY TO
DISCHARGE TO A RIPRAP APRON AND VEGETATED SWALE.
3.LOT 7 HAS A MAILING ADDRESS OF 1121 EAST LAKE ROAD AND IS IDENTIFIED AS LOT
35-7 ON THE TOWN OF MONTVILLE TAX ASSESSOR'S MAP 7. THE DEED REFERENCE OF
THE PROPERTY IS VOLUME 700 PAGE 241.
4.THE PURPOSE OF THIS PLAN IS FOR REVIEW BY THE TOWN OF MONTVILLE PLANNING
& ZONING COMMISSION FOR A SUBDIVISION MODIFICATION.
5.ELEVATIONS SHOWN HEREON ARE BASED ON APPROXIMATE NAVD-88 DATUM PER
REFERENCE MAP 'A'.
REFERENCE INFORMATION:
1.THIS PLAN WAS COMPILED USING THE FOLLOWING REFERENCE INFORMATION:
A.A PLAN SET ENTITLED, "SUBDIVISION PLAN, PREPARED FOR SUNMAR/RAF
BUILDERS, LLC, PROPERTY OF WALTER N. WAINWRIGHT, JR. EAST LAKE ROAD &
FIRE STREET, MONTVILLE (OAKDALE), CONNECTICUT," DATED JUNE 2022, LAST
REVISED JULY 11, 2022, PREPARED BY BOUNDARIES, LLC.
"APPROVED BY THE MONTVILLE
PLANNING & ZONING COMMISSION"
DATESIGNATURE OF CHAIR OR SECRETARY
29798No.
M.M
AR
O
NSAM
EU S
LICE N S E DRPFOS
E
ISONA L NE IG ENS ERSTATEO F C ONNE
C
T
CI
UTDESCRIPTION OF REVISIONDRAWING
SHEET NUMBER:OF
CHECKED BY:DATE:
DRAWN BY:DATE:
PROJECT NO.SCALE:DATEAPPR.REV.H HENGINEERINGASSOCIATES
232 Greenmanville Ave.
Suite 201
Mystic, CT 06355
860-980-8008
www.hh-engineers.com
PREPARED FOR:PROPERTY ADDRESS:SITE DETAILSSUBDIVISION MODIFICATIONEAST LAKE ROAD & FIRE STREET, MONTVILLE, CT 06370SUNMAR/RAF BUILDERS, LLC285 OLD COLCHESTER ROAD, UNCASVILLE, CT 063822024-0177 AS NOTED
SMM 3/28/2025
SMM 3/28/2025
DT-1
3 3
Z:\SHARED\H+H ENGINEERING ASSOCIATES\PROJECTS\2024\2024-0177 - RICK FRANKLIN - 1121 EAST LAKE RD, OAKDALE\DWGS\SITE PLAN.DWG Tab: DETAILS Saved: 3/28/2025 10:13 AM Plotted: 3/28/2025 10:14 AMREINFORCED CONCRETE FLARED END SECTION
NOT TO SCALE
NOTES:
1.ALL PRECAST CONCRETE PRODUCTS MUST HAVE THE CASTING DATE CLEARLY
LABELED AND SHALL NOT BE DELIVERED WITHIN 7 DAYS OF THE CASTING DATE.
2.JOINT SHALL BE TONGUE AND GROOVE OR BELL AND SPIGOT AS REQUIRED TO
CONFORM TO PILE INSTALLED.
3.WALL THICKNESS SHALL CONFORM TO PIPE THICKNESS.
REINFORCED CONCRETE PIPE CONFORMS TO ASTM C-76, ASTM-C-443, ASHTO M-170,
AND AASHTO M-198.
DIA.A B C D E R1 R2
12"4"24"48 7/8"24"3"10 1/4"9"
15"6"27"46"30"3"12 1/2"11"
18"9"27"46"36"3"15 1/2"12"
24"9-1/2"43-1/2"30"48"3"16 13/16"14"
30"12"54"19-3/4"60"3 1/2"18 1/2"15"
36"15"63"34-3/4"72"4"24 5/16"20"
42"21"63"35"78"4 1/2"27 1/2"22"
48"24"72"26"84"5 28 1/2"22"
54"27"65"35"90"5 1/2"33 1/8"24"
60 30"60"39"96"6"36 11/16"24"DIA.WALLWALLC B
ATONGUE OR GROOVE DIA. +1"WALL
E
WALLWALLDWALLDIA.X
X
R2
DIA.SECTION X-X
R1
R=1 1/2"
2'-7" DIA.5"5"
2-5" DIA.
2'-3 12" DIA.
1'-11" DIA.
3"
34"
8"
A A'
15°
2'-1 12" DIA.
2'-1" DIA.
34" RAISED LETTERS AS REQUIRED
BY STATE, LOCAL OR FEDERAL
STANDARDS
NOTES:
1.STORM MANHOLE FRAMES AND COVERS SHALL CONFORM TO CTDOT FORM 817 STANDARD
SPECIFICATION FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION AND CT DOT
HIGHWAY STANDARD SHEETS HW-507_10, AS AMENDED.
2.CHANNELS MAY BE SHAPED IN CONCRETE BASE OF MANHOLD ORFORMED USING BRICK OR
MASONRY, UNLESS OTHERWISE DIRECTED.
3.A FRAME OF 3'-3" WITH 4" FLANGE SHALL BE USED WHEN THE TOP DIAMETER OF A PRECAST
CONE IS LESS THAN 3'-6". ALL OTHER FRAME DIMENSIONS SHALL REMAIN THE SAME.
4.ALL DIMENSIONS SUBJECT TO MANUFACTURING TOLERANCES.
REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW-507_04 & HW-507_10, CT DOT FORM 817.
STORM
PICK HOLE
NON-SKID LUGS
1 12"∅BONDINGHOLES, 8 EA.
1 12" ∅ HANDLING HOLES, 2REQUIRED
STORM MANHOLE FRAME & COVER DETAIL
NOT TO SCALE
PLAN
SECTION A-A'
RIPRAP APRON DIMENSIONS
OUTLET W1 La W2
FES-1 6 16 18
NOTE:
IN ACCORDANCE WITH CT DOT DRAINAGE MANUAL SECTION 11.13 - OUTLET PROTECTION,
ALL APRON STONE SHALL BE INTERMEDIATE RIPRAP (DISCHARGE VELOCITY 8-10 FT/S)
RIPRAP APRON
NOT TO SCALE
W1
W2La CONCRETE FLARED END SECTION
12" MODIFIED RIPRAP
6" PROCESSED GRAVEL
NON-WOVEN
GEOTEXTILE FABRIC
HDPE TO CONCRETE PIPE CONNECTION
(SEE DETAIL)NEW
G
R
A
D
E
HDPE PIPE
NOTES:
1.PRECAST CONCRETE MANHOLE COMPONENTS SHALL CONFORM TO CTDOT STANDARD SHEET HW-507_10 AS AMENDED.
2.4', 5' OR 6' PRECAST CONCRETE BASE DIAMETERS MAY BE USED WHEN REQUIRED DUE TO SIZE OR NUMER OF PIPES AT THE MANHOLE.
PRECAST REDUCERS WILL BE PLACED ABOVE THE 5' AND 6' BASES AS DIRECTED BY THE ENGINEER. WALL THICKNESS SHALL INCREASE 1"
FOR EACH 1' OF INSIDE DIAMETER INCREASE.
3.JOINT SEALANT SHALL BE BUTYL RUBBER MASTIC TYPE SEAL THAT CONFORMS TO LATEST AASHTO SPECIFICATION M-198 & MEETS
FEDERAL SPECIFICATION SS-S-0021(210-A).
4.REINFORCING STEEL DEFORMED BARS ARE NOT SHOWN AND SHALL CONFORM TO LATEST CTDOT STANDARDS & SUPPLEMENTALS AND
ASTM SPECIFICATION A615, GRADE 60, MINIMUM COVER 2", UNLESS OTHERWISE NOTED.
5.ALL PIPE OPENINGS SHALL BE CLOSED USING MATERIALS WHICH CONFORM TO STATE OF CT STANDARD SPECIFICATIONS SECTION M.08.02.
6.REINFORCING STEEL WELDED WIRE FABRIC SHALL CONFORM TO LATEST ASTM SPECIFICATION A185.
7.CONCRETE COMPRESSIVE STRENGTH SHALL BE MINIMUM 4000 PSI AT 28 DAYS, SELF COMPACTING CONCRETE MIX.
8.MANHOLE STEPS SHALL MEET LATEST OSHA REGULATIONS, (29 CFR 1910.27), SECTION 16 OF ASTM SPECIFICATION C478 AND SECTION 10
OF ASTM SPECIFICATION C497.
9.WHEN SPECIFIED, MANHOLES ARE TO BE COATED WITH BAY OIL, "EBONY".
10.METHOD OF MANUFACTURE SHALL BE WET CAST.
11.BASE SECTION IS MONOLITHIC.
12.MANHOLE INTERIOR DIAMETER:
4'-0" FOR 8" TO 36" PIPE DIAMETERS
5'-0" FOR 42" PIPE DIAMETER
6'-0" FOR 48" PIPE DIAMETER.
REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW-507_04 & HW-507_10, CT DOT FORM 817 AND (MANHOLE STEPS) THE METROPOLITAIN
DISTRICT SEWER STANDARD DETAILS FIG. 5-34, DATED JAN. 2017.
COPOLYMER POLYPROPYLENE PLASTIC
STEEL REINFORCED MANHOLE STEP
FOR CONCRETE MANHOLES
A A'
A
A'
STANDARD PRECAST CONCRETE STORM MANHOLE DETAIL
NOT TO SCALE
END VIEW
SECTION A-A'
PLAN
SIDE VIEW
PLANSECTION A-A'
SEE STORM MANHOLE
FRAME & COVER FOR DETAIL
OPENING 24"∅ TYP.
(30" OR 36" AVAILABLE)
ADJUST TO GRADE
WITH MAXIMUM OF
4 COURSES OF BRICK
ECCENTRIC CONE
HEIGHT VARIES
3', 4' & 5'
(W/ 24"∅ OPENING)
RISER HEIGHT
VARIES
1', 2', 3', & 4'
BASE HEIGHT
VARIES
3', 4', & 6'
MANHOLE STEPS
(SEE DETAIL)
12" TYP.
SEE NOTE #2
FOR MANHOLE DIA.
5" WALL
(TYP.)
PACK ANNULAR
SPACE WITH
NON-SHRINK
GROUT (TYP.
BOTH SIDES)CONCRETE OR
BRICK & MORTAR
INVERT
KNOCKOUTS FOR
PIPES 4" MIN. FROM
TOP & BOTTOMOF BASE
PROVIDE ADEQUATE
BEDDING AS REQUIRED
BY CT DOT FORM 817
5'-10" DIA.
4"
MIN.
6" TYP.
COPOLYMER
POLYPROPYLENE
PLASTIC
1/2" GRADE 60 STEEL
REINFORCEMENT
PRECAST CONCRETE
1 1316"
1 38"
8 14"
1 316"
15 78"
3 18"5 18"
15 78"
14"
CONCRETE OR
BRICK INVERT
COUPLING OF ADJACENT STAKES
INSTALLATION NOTES FOR SILT FENCE:
1.PLACE SILT FENCE ON CONTOUR AND WITH LAST STAKES UPSLOPE SO THAT
THE TOP OF LAST SEVERAL STAKES ARE HIGHER THAN LINE OF SILT FENCE.
2.EXCAVATE TRENCH 6" MIN. AND PLACE FILL UPSLOPE OF TRENCH.
3.PLACE SILT FENCE AND STAKE FIRST STAKE AT ANGLE TOWARDS FIRST STAKE.
STAKES ARE 18" MIN. INTO GROUND.
4.BACKFILL & COMPACT EXCAVATED FILL ALONG UPHILL SIDE OF SILT FENCE.
TYPICAL SEDIMENT BARRIER DETAIL
NOT TO SCALE 36"6"2"x2"x48"
WOOD POST
SILT FENCE
FINISH
GRADE80°COMPACTED
BACKFILL 12"MANUFACTURER'S
COUPLER OR BIND
WITH WIRE
SECTION 'A'
STAKE 'A'
STAKE 'B'
SECTION 'B'
SECTION 'B'
STAKE 'B'
SECTION 'A'
STAKE 'B'
1
3B
3A
5
NOTES:
1.PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. WHEN USING
CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN.
2.BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP x 6" (15cm), WIDE TRENCH WITH APPROXIMATELY 12"
(30CM) OF BLANKET EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF
STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER
STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm), PORTION OF BLANKET BACK OVER SEED AND COMPACTED
SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE
WIDTH OF THE BLANKET. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 cm) MAY BE
NECESSARY TO PROPERLY SECURE THE BLANKETS.
3.ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST
THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE
LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM TM, STAPLES/STAKES SHOULD BE PLACED
THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN.
4.THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5czm-12.5cm), OVERLAP DEPENDING ON BLANKET TYPE.
TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH
THE COLORED SEAM STITCH TM ON THE PREVIOUSLY INSTALLED BLANKET.
5.CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5cm)
OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30cm), APART ACROSS ENTIRE BLANKET WIDTH.
4 2
EROSION CONTROL BLANKET DETAIL
NOT TO SCALE
2"-5"
(5cm -
12.5cm)
12"
(30cm)6"(15cm)6"
(15cm)
NORTH AMERICAN GREEN
BIONET BIODEGRADABLE
EROSION CONTROL BLANKET
3"
(7.5cm)
FINISHED GRADING,
TOPSOIL & SEEDING
FLOW
GRASSED SWALE DETAIL
NOT TO SCALE
INSTALL JUTE
NETTING IN
GRASS SWALE
(TYP.)
12"
MIN.12' (MIN.)
12"
(MIN.)
6'
6" LOAM AND
SEED (MIN.)3:1 (MAX.)
2'-7" DIA.5"5"
2-5" DIA.
2'-3 12" DIA.
1'-11" DIA.
3"
34"
8"
A A'
15°
2'-1 12" DIA.
2'-1" DIA.
34" RAISED LETTERS AS REQUIRED
BY STATE, LOCAL OR FEDERAL
STANDARDS
NOTES:
1.STORM MANHOLE FRAMES AND COVERS SHALL CONFORM TO CTDOT FORM 817 STANDARD
SPECIFICATION FOR ROADS, BRIDGES AND INCIDENTAL CONSTRUCTION AND CT DOT
HIGHWAY STANDARD SHEETS HW-507_10, AS AMENDED.
2.CHANNELS MAY BE SHAPED IN CONCRETE BASE OF MANHOLD ORFORMED USING BRICK OR
MASONRY, UNLESS OTHERWISE DIRECTED.
3.A FRAME OF 3'-3" WITH 4" FLANGE SHALL BE USED WHEN THE TOP DIAMETER OF A PRECAST
CONE IS LESS THAN 3'-6". ALL OTHER FRAME DIMENSIONS SHALL REMAIN THE SAME.
4.ALL DIMENSIONS SUBJECT TO MANUFACTURING TOLERANCES.
REFERENCE: CT DOT HIGHWAY STANDARDS, SHEET HW-507_04 & HW-507_10, CT DOT FORM 817.
STORM
PICK HOLE
NON-SKID LUGS
1 12"∅BONDING
HOLES, 8 EA.
1 12" ∅ HANDLING HOLES, 2REQUIRED
STORM MANHOLE FRAME & COVER DETAIL
NOT TO SCALE
PLAN
SECTION A-A'
REFERENCE: CT DOT HIGHWAY JANUARY 2025 STANDARDS & GUIDE SHEETS, SHEET CTDOT_HIGHWAY_DG JAN 2025 [10-30-24]
PERMANMENT CHECK DAM DETAIL
NOT TO SCALE
X-SECTION
PLAN VIEW
EXISTING GROUND
6" MIN 18"
18" MAX.
6"
2 MAX1
TOP OF STONE CHECK DAM
NO. 3 CRUSHED STONE
OR RIPRAP AS DIRECTED
FLOW
GRASS LINED CHANNEL
18" MAX.
LENGTH (L)
VARIES BASED ON SLOPE (SEE TABLE)
18" MAX.
MATCHES AT GRADE
CHANNEL 6% MA. SLOPE 2 MAX1
2 MAX1
NO. 3 STONE
ELEVATION
SPACING BETWEEN CHECK DAMS
FLOW
FLOWMAXIMUM SPACING BETWEEN
DAMS FOR A 1.5' CHECK DAM HEIGHT
CHANNEL SLOPE LENGTH
1% TO 3%50'-0"
4%38'-0"
5%30'-0"
6%25'-0"
NO. 3 STONE