ROAD CLOSED
0.1 MILES AHEAD
ROAD
LOCAL TRAFFIC ONLY
CLOSED
DETOUR
DETOUR
BRIDGE STREET
CLOSED TO
THRU TRAFFIC
ROAD CLOSED
TO
THRU TRAFFIC
M:\7000\7700\7767D - Bridge St Bridge Inspection\Drawings\7767D Bridge St Bridge Deck Replacement - PLAN SET.dwg
M:\7000\7700\7767D - Bridge St Bridge Inspection\Drawings\7767D Bridge St Bridge Deck Replacement - PLAN SET.dwg
M:\7000\7700\7767D - Bridge St Bridge Inspection\Drawings\7767D Bridge St Bridge Deck Replacement - PLAN SET.dwg
M:\7000\7700\7767D - Bridge St Bridge Inspection\Drawings\7767D Bridge St Bridge Deck Replacement - PLAN SET.dwg
#7 @ 912" O.C. BOT.#7 @ 12" O.C. BOT.3'-112"3'-112"3'-112"3'-112"3'-112"1'-6"3'-112"3'-112"3'-112"3'-112"3'-112"1'-3"RAIL POST, TYP.
MATCH EDGE OF EXIST. DECK, TYP.
EXIST ABUTMENT, TYP.
Sb-1
1
Sb-2
1
GUIDERAIL TRANSITION PER
CTDOT HW910_14b, TYP.
2'-6"
1% SLOPE, MIN.
2'-6"
1'-6"
1% SLOPE, MIN.
2'-0"
ASPHALT OVERLAY (6" MAX.)
#7s @ 912" O.C. BOT (2" COVER)
1'-6" BRIDGE DECK
2" COVER, T&B
#7s @ 12" O.C. BOT
MEMBRANE PER CT DOT 817: 7.07
2" TYPE "S" MORTAR, TYP.
CONCRETE APRON 4"MIN.2"2"1"MINEXIST. WALL TO REMAIN, TYP.
ASSURE PROPER DISCHARGE @ SWALE, TYP.1"MIN4"MIN.#5s @ 12" O.C. TOP
#7s @ 12" O.C. TOP (2" COVER)
STRUT BRACE/WHALER
SHOWN, ACTUAL SHORING
DESIGN BY OTHERS
TEMPORARY SHORING DURING BRIDGE REMOVAL
ENGINEERED SHORING DESIGN BY OTHERS
18" NEOPRENE PAD, FULL WIDTH, TYP.
REPAIR ANY DAMAGED AREAS
STRUCTURAL REPAIR PLANSECTION DETAIL @ BEAM1
Sb-1 SCALE: 3/4" = 1'-0"
PROP. LAYOUT SHOWING BOT. REINFORCEMENT
SCALE: 1/4" = 1'-0"NUMBER DATEREVISIONCLA PROJECT NO.
PROJ. ENGINEER
DATE:
SHEET NO.URVEYINGSwww.claengineers.comTRUCTURAL(860) 886-1966 Fax (860) 886-9165317 Main Street Norwich, ConnecticutSCIVIL7767d
ADB
2025-03-21
SB-1(OF 2 SHEETS)±32 Bridge St, Uncasville, CT 06382EXISTING RAIL CROSSING BRIDGEBRIDGE DECK REPLACMENTCLACLA Engineers, Inc.C1. GENERAL: ALL CONCRETE WORK SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTES "SPECIFICATIONS FOR STRUCTURAL
CONCRETE FOR BUILDINGS" (ACI 301-95).
C2. CONCRETE MIXES SHALL INCLUDE MID-RANGE WATER REDUCING ADMIXTURE OR PLASTICIZER AND SHALL HAVE A DESIGN SLUMP
OF 5” WITH A MAXIMUM PLACEMENT SLUMP OF 6.5". HIGHER SLUMPS ARE ALLOWABLE IF HIGH RANGE PLASTICIZERS ARE USED.
CONCRETE FOR BRIDGE:
f'c = 5OOO PSI AT 28 DAYS, w/c RATIO = O.47 (MAX), AIR ENTRAINMENT = 6%
C3. REINFORCING STEEL: ASTM A615 - GRADE 60.
C4. BAR DETAILING: IN ACCORDANCE WITH THE "ACI DETAILING MANUAL - 1988". PLACING DRAWINGS SHALL SHOW THE NUMBER AND
LOCATION OF ALL BAR SUPPORTS AND ACCESSORIES.
C5. ALL REBAR IS TO BE HOD DIPPED GALVANIZED PER ASTM A767. ANY DAMAGED AREAS ARE TO BE PAINTED WITH COLD
GALVANIZING COMPOUND CONFORMING TO ASTM A780.
C6. CONCRETE CLEAR COVER:
SHALL BE AS FOLLOWS: CONCRETE POURED AGAINST EARTH.............. 3"
CONCRETE POURED IN FORMS BUT EXPOSED TO EARTH OR WEATHER:
5 BARS AND SMALLER.................. 2"
LARGER THAN #5 BARS............... 2"
G1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2021 INTERNATIONAL BUILDING CODE, AS AMENDED FOR THE 2022
CONNECTICUT BUILDING CODE.
G2. THE OWNER/CONTRACTOR SHALL SUBMIT 2 COPIES MINIMUM OF SHOP DRAWINGS FOR ALL COMPONENTS OF THE PRIMARY
STRUCTURAL SYSTEM FOR REVIEW BY THE STRUCTURAL ENGINEER OF RECORD. THE OWNER/CONTRACTOR SHALL ALLOW A
MINIMUM OF TWO (2) WEEKS FOR THE REVIEW BY THE STRUCTURAL ENGINEER OF RECORD.
G3. THE GENERAL CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR MEANS AND METHODS OF CONSTRUCTION AND SAFETY ON THE
JOB SITE.
G4. ALL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE SHOWN FOR REFERENCE ONLY CONTRACTOR IS TO VERIFY ALL
DIMENSIONS, ANGLES, ELEVATIONS, etc. PRIOR TO THE START OF CONSTRUCTION OR THE FABRICATION OF BUILDING COMPONENTS.
G5. THE GENERAL CONTRACTOR SHALL FURNISH COMPLETE SETS OF DRAWINGS TO ALL SUBCONTRACTORS FOR USE IN SHOP DRAWING
PREPARATION.
G6. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE SPECIFICATIONS AND ANY OTHER RELEVANT DRAWINGS.
G7. TEMPORARY SHORING DESIGN STAMPED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF CT SHALL BE SUBMITTED FOR
REVIEW AND APPROVAL PRIOR TO DEMOLITION. THE OWNER/CONTRACTOR SHALL ALLOW A MINIMUM OF TWO (2) WEEKS FOR THE
REVIEW BY THE STRUCTURAL ENGINEER OF RECORD.
GENERAL STRUCTURAL NOTES
CONCRETE / REINFORCED CONCRETE
ABBREVIATIONS LEGEND
A.O.D. = AT OWNER's DISCRETION
BTWN. = BETWEEN
℄ = CENTER LINE
CLR. = CLEAR
COORD.= COORDINATE
CONC. = CONCRETE
CONN. = CONNECT
CONT. = CONTINUOUS
DEG. = ° = DEGREES
DIA. = ø = DIAMETER
DNS = DO NOT SCALE
DWL. = DOWEL
EA. = EACH
EoR = ENGINEER OF RECORD
ELEV. = ELEVATION
EMBED. = EMBEDMENT
EQ. = EQUAL
EXIST. = EXISTING
f'c = CONC. COMPRESSIVE STRENGTH
FT. = FOOT OR FEET
FTG. = FOOTING
GA. = ga. = GAUGE (THICKNESS)
H.D.G. = HOT DIPPED GALVANIZED
HMA = HOT MIX ASPHALT
HORIZ. = HORIZONTAL
IN. = INCH
K = KIP = 1,000 POUNDS
LAT. = LATERAL
LONG. = LONGITUDINAL
ld = DEVELOPMENT LENGTH
MAX. = MAXIMUM
MECH. = MECHANICAL
MIN. = MINIMUM
MFR. = MANUFACTURER
NTS = NOT TO SCALE
O.C. = ON CENTER
O.H. = OPPOSITE HAND
PROJ. = PROJECTION
PSF = POUNDS PER SQ. FT.
PSI = POUNDS PER SQ. IN.
PT = PRESSURE TREATED
⅊ = PLATE
REINF. = REINFORCEMENT
REQ. = REQUIRED
SIM. = SIMILAR
SQ. = SQUARE
STD. = STANDARD
T.B.D =TO BE DEMOLISHED
T.B.R =TO BE REMOVED
T.o.C. = TOP OF CONCRETE ELEV.
T/ WALL = TOP OF WALL ELEV.
T/ SHELF = TOP OF SHELF ELEV.
THR. = THREADED
TYP. = TYPICAL
SQ. FT. = SQUARE FEET
U.N.O.= U.O.N. = UNLESS NOTED OTHERWISE
VERT. = VERTICAL
V.I.F. = VERIFY IN FIELD
w/ = WITH
W.W.F. = WELDED WIRE FABRIC
STONE ABUTMENT NOTES (FOR POTENTIAL REPAIRS)
1. ALL WALL CONSTRUCTION IS TO BE DOCUMENTED IN ORDER TO PROVE CONFORMANCE TO THESE CONSTRUCTION DOCUMENTS,
PARTICULARLY PROPER COMPACTION OF SOILS AND THE PRESENCE OF DRAINAGE MATERIALS. COORDINATING THIS DOCUMENTATION IS THE
RESPONSIBILITY OF THE CONTRACTOR. IT IS OUR RECOMMENDATION THAT THE GRID LENGTH BE VERIFIED BY THE INSPECTING AGENCY
DURING FIELD DENSITY TESTING OF SOILS. IN ADDITION TO DOCUMENTATION BY THIRD PARTY INSPECTION, ALL ELEMENTS OF THE WALL
SYSTEM SHOULD BE THOROUGHLY PHOTOGRAPHED FOR DOCUMENTATION.
2. ALL FIELD STONE IS TO BE DURABLE, IGNEOUS OR METAMORPHIC STONE FREE OF FERROUS MINERALS/RUST STAINING. ALL STONES ARE TO
LAIN TO TIGHT SMOOTH INTERFACE (NO ROUND BOULDERS), OR FULLY CHINKED AND MORTARED TO AN EQUIVALENTLY SMOOTH INTERFACE.
IN PARTICULAR, TIE-STONES ARE TO BE ANGULAR STONES WITH FLAT FACETS FACING ALL ADJACENT WALL STONES (NO ROUND BOULDERS).
3. RETAINED SOIL SHALL BE DETERMINED TO MEET OR EXCEED THE REQUIREMENTS BELOW. SOILS NOT MEETING THESE REQUIREMENTS SHALL
BE EXCAVATED AND REPLACED WITH ACCEPTABLE SOILS. IF WEAK SOILS ARE PRESENT, THEY SHALL BE EXCAVATED AND REPLACED WITH
ACCEPTABLE SOILS.
ONCE THE BASE COURSE ELEVATION IS ACHIEVED, THE AREA IS TO BE PROOF COMPACTED WITH VIBRATORY COMPACTION EQUIPMENT PRIOR
TO PLACING THE LEVELING PAD.
RETAINED SOIL SHALL BE CLEAN "BANK RUN GRAVEL" (USCS SW OR SW/SM) WITH NO MORE THAN 10% PASSING THE #200 SIEVE AND SHALL MEET
OR EXCEED THE REQUIREMENTS BELOW. ORGANIC AND FROST SUSCEPTIBLE SOILS ARE NOT PERMITTED WITHIN A MIN. DISTANCE BEHIND THE
WALL EQUAL TO THE HEIGHT OF THE WALL.
4. ALL DRAINAGE AND FOUNDATION SOIL SHALL BE COMPACTED TO 95% OF ITS MAX. DRY DENSITY, AS DETERMINED BY ASTM D1557 (3-POINT
CURVE ACCEPTABLE).
5. THE FOLLOWING MINIMUM SOIL PROPERTIES WERE USED IN THE DESIGN:
SOIL TYPE SOIL WEIGHT (PCF)MINIMUM FRICTION ANGLE (DEG)
BACKFILL SOIL*135 MAX.34
RETAINED SOIL 135 MAX.34
FOUNDATION SOIL 125 MIN.30
LEVELING PAD 125 MIN.40
FREE DRAINING BACKFILL 135 MAX.34
*BACKFILL SOIL IS DEFINED AS ALL SOIL PLACED IN LIFT BEHIND THE WALL, EXCEPTING THE CRUSH STONE
6. ENSURE THAT THE FIRST COURSE OF WALL UNITS IS IN FULL CONTACT WITH THE LEVELING PAD. INSTALL NEXT COURSE OF UNITS SUCH THAT
THE VERTICAL GAPS ARE STAGGERED BETWEEN ADJACENT COURSES. GAPS SHALL BE PROPERLY CHINKED PRIOR TO STARTING THE NEXT
COURSE.
7. CONTRACTOR AND LANDSCAPE ARCHITECT / OWNER SHALL APPROVE/PROVIDE ALL ELEVATIONS AND INVERTS IN THESE PLANS PRIOR TO
ORDERING MATERIAL.
8. STONES SHALL BE SET BACK WHEN STEPPING UP AND SET FORWARD WHEN STEPPING DOWN. WALL ANGLES SHALL BE SLIGHTLY ADJUSTED TO
ACCOMMODATE PROPERTY LINES AND OBSTRUCTIONS.
LIVE LOADS WIND LOADS SEISMIC (EARTHQUAKE) LOADS
PER ASCE 7-10
(CHAPTER 30)
64 PSF
32 K
25K @ 48" O.C.
HL93
1.0
1.33
125 MPH
II
B
+/- 0.18
1.0
0.198
0.054
Ss
S1
D
BSEISMIC DESIGN CATEGORY
SITE CLASSIFICATION
IMPORTANCE FACTOR (Ie)
COMPONENTS & CLADDING
INTERNAL PRESSURE COEFF.
WIND EXPOSURE
RISK CATEGORY
BASIC WIND SPEED (3-SEC)UNIFORM LANE LOAD
DESIGN SINGLE AXLE LOAD
DESIGN TANDEM AXLE LOAD
STATIC LOAD STANDARD
IMPORTANCE FACTOR (Is)
IMPACT FACTOR
MAPPED SPECTRAL RESPONSE
ACCELERATION
DESIGN LOADS TABLE
STRUCTURAL STEEL
S1. MATERIALS:
STRUCTURAL STEEL, WIDE FLANGE ..........ASTM A572-gr50 OR A992
STEEL PLATES CHANNELS, & ANGLES........ASTM A36
BOLTS...................................................................ASTM A325-3/4" DIA. STD
NUT/WASHER
WELDING ELECTRODES.................................ASTM A233 E 70 SERIES
ANCHOR RODS..................................................ASTM A193 Gr. 8-m CLASS
1, 316 SS - 75ksi Fult, 30ksi Fy
S2. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND
ERECTED IN ACCORDANCE WITH THE LATEST PROVISIONS OF
THE "SPECIFICATIONS FOR THE DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" OF THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 14TH EDITION
AND THE "AISC CODE OF STANDARD PRACTICE FOR STEEL
BUILDINGS AND BRIDGES".
S3. SHOP AND ERECTION DRAWINGS SHALL BE SUBMITTED BY THE
CONTRACTOR FOR ALL STRUCTURAL STEEL WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS. SUBMIT TWO
PRINTS. DO NOT PROCEED WITH FABRICATION WITHOUT SHOP
DRAWING REVIEWED BY THE ENGINEER OF RECORD.
S4. STORE MATERIALS TO PERMIT EASY ACCESS FOR INSPECTION
AND IDENTIFICATION. KEEP STEEL MEMBERS OFF GROUND AND
SPACED BY USING PALLETS, DUNNAGE, OR OTHER SUPPORTS
AND SPACERS. PROTECT STEEL MEMBERS AND PACKAGED
MATERIALS FROM CORROSION AND DETERIORATION. DO NOT
STORE MATERIALS ON STRUCTURE IN A MANNER THAT MIGHT
CAUSE DISTORTION, DAMAGE, OR OVERLOAD TO MEMBERS OR
SUPPORTING STRUCTURES. REPAIR OR REPLACE DAMAGED
MATERIALS OR STRUCTURES AS DIRECTED. STORE FASTENERS IN
A PROTECTED PLACE IN SEALED CONTAINERS WITH
MANUFACTURER'S LABELS INTACT. CLEAN AND RELUBRICATE
BOLTS AND NUTS THAT BECOME DRY OR RUSTY BEFORE USE.
S5. BOLTING: COMPLY WITH REQUIREMENTS OF AISC
"SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325
BOLTS.
S6. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF THE
AMERICAN WELDING SOCIETY (AWS) STRUCTURAL WELDING
CODE STEEL D1.1, LATEST EDITION, BY CERTIFIED WELDERS AND
QUALIFIED WELDING PROCEDURES. SHIELDED METAL ARC
METHOD OF WELDING SHALL BE USED FOR ALL WORK. WELDING
ELECTRODES, WELDING PROCESS, MINIMUM PREHEAT AND
INTERPASS TEMPERATURES SHALL BE IN ACCORDANCE WITH
THE AISC AND AWS SPECIFICATIONS. ANY STRUCTURAL STEEL
DAMAGED BY WELDING IS TO BE REPLACED OR REINFORCED AS
ACCEPTABLE TO THE STRUCTURAL ENGINEER.
S7. ALL STEEL MUST BE HOT DIPPED GALVANIZED (HDG) PER ASTM
A123 (A153 FOR FASTENERS). ALL AREAS OF HDG DAMAGED BY
OPERATIONS, ESPECIALLY WELDING, ARE TO BE REPAIRED PER
ASTM A780 SOLDER METHODOLOGY UPON COMPLETION OF THE
OPERATION TO THE WRITTEN SATISFACTION OF THE ENGINEER,
EXCEPT REBAR, WHICH IS TO BE REPAIRED PER NOTE C5.
S8. MINIMUM FILLET WELD SIZE SHALL BE 1/4" UNLESS OTHERWISE
SHOWN ON THE DRAWINGS. RECORDS OF WELDER
QUALIFICATIONS SHALL BE MAINTAINED AND AVAILABLE FOR
OWNERS REVIEW.
#5 @ 12" O.C., TYP.NEW 1'-6"x27'-6" REINF. CONC. BRIDGE
ASPHALT, 6" MAX. ALLOWABLE THICKNESS
NEW 4" CONCRETE DECK
MEMBRANE
PER CT DOT
817: 7.07#7 @ 12" O.C., TYP.
#7 @ 912" O.C., TYP.
#7 @ 12" O.C., TYP.
NEW W6x25 HDG POST @ 3712" ON CENTER
NEW DBL [NESTED] 12 ga. THRIE-BEAM, CENTER 22" ABOVE DECK
(4) 34" ø 24" LONG 316 SS ASTM A193gr8m-c1 HASR-SS BOLTS, (1) EA. SIDE OF POST, 2" FROM CENTER LINE OF POST, WET-SET PER DET.
38"x6"x25" D50+ NEOPRENE PAD
TYP. 58" BOLT CONN., TYP. OF 2 PER POST, STAGGERED, (1) EACH SIDE OF POST FLANGE, 2" FROM CENTERLINE OF POST
38"x6"x10" D50+ NEOPRENE PAD
10" PAD38"
MC8x8.5
±11"SEE POST TO RAIL CONN. DETAIL
5"412"812"1"3'-6"4"A.O.D. COMPACT ASPHALT EDGE BETWEEN POSTS SIMILAR TO BERM, TYP.
TACK COAT ON HDG POST PRIOR TO HMA INSTALLATION, TYP.
ASPHALT SHOWN AS 4" AT EDGE FOR DETAILING, CROWN
SS316 COUPLERS MAY BE USED A.C.D., TYP.
58" BOLT
TYP. POST TO RAIL SHEAR CONN. DETAIL2
Sb-2 SCALE: 3/4" = 1'-0"
SECTION
SCALE: 3/4" = 1'-0"
A
BOLT
STEEL RAIL WEB
STEEL POST WEB
L312"x312"x3/8", TYP.
L312"x312"x3/8"
POST
ELEVATION
SCALE: 3/4" = 1'-0"
TOP RAIL 1/4
A
24DD
1.5D1.5DBASE PLATE
14" NEOPRENE PAD
PROP. CONCRETE
THREADED & NUTTED
ANCHOR RODS PER
PLANS
(2) NUTS TACK WELDED
OR PEENED IN PLACE,
PER AISC REQ. (PART 14:
ANCHOR
RODS:HEADED), TYP.
ANCHOR DETAIL @ RAIL POST
SCALE: 1 - 1/2" = 1'-0"
NOTE: DO NOT OVER-TIGHTENING NUTS
STRUCTURAL REPAIR PLANTRANSVERSE SECTION1
Sb-2 SCALE: 3/4" = 1'-0"NUMBER DATEREVISIONCLA PROJECT NO.
PROJ. ENGINEER
DATE:
SHEET NO.URVEYINGSwww.claengineers.comTRUCTURAL(860) 886-1966 Fax (860) 886-9165317 Main Street Norwich, ConnecticutSCIVIL7767d
ADB
2025-03-21
SB-2(OF 2 SHEETS)±32 Bridge St, Uncasville, CT 06382EXISTING RAIL CROSSING BRIDGEBRIDGE DECK REPLACMENTCLACLA Engineers, Inc.