HomeMy WebLinkAbout23SITE1-689OCR Office Bldg Arch Plan 011023WALL SECTION CALLOUTSHEET WHERE SECTION IS SHOWNDETAIL CALLOUTSHEET WHERE DETAIL IS SHOWNCALLOUT NUMBERSHEET WHERE CALLOUT IS SHOWNEXTERIOR ELEVATIONSHEET WHERE ELEVATION IS SHOWNINTERIOR ELEVATIONSHEET WHERE ELEV. IS SHOWNA1011234COLUMN BUBBLESACCESSIBILITY CLEARANCES:TURNING RADIUS0WINDOW TAG NUMBERDOOR TAG NUMBERACCESSIBILITY CLEARANCES:CLEAR FLOOR SPACEGRAPHIC SYMBOLS LEGENDBUILDING SECTION CALLOUTSHEET WHERE SECTION IS SHOWNA1011A1.12STEELALUMINUMCONCRETE MASONRY UNIT (SECTION)BRICK (SECTION)CONCRETEEARTHGRAVEL / COMPACTED FILLGYPSUM / PLASTERSANDBATT INSULATIONRIGID INSULATIONFINISH WOOD (ELEVATION)FINISH WOOD (SECTION)PLYWOODWOOD FRAMING OR WOOD BLOCKING (CONTINUOUS)WOOD BLOCKING (NON-CONTINUOUS)EXISTING ITEMS TO REMAINMATERIAL LEGENDCONCRETE MASONRY UNIT (ELEVATION)BRICK (ELEVATION)CRUSHED STONEDRAWING SHEET INDEX:1. DO NOT SCALE DRAWING OR DIMENSIONS. FOR MISSING DIMENSIONS OR DIMENSIONS IN CONFLICT, CONTACT THE CONTRACTOR IMMEDIATELY BEFORE CONTINUING WITH WORK.2. ANY DISCREPANCIES IN THESE PLANS WILL BE BROUGHT TO THE CONTRACTOR'S ATTENTION IN WRITING IMMEDIATELY3. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DESIGN-BUILD PLANS AND SPECIFICATION FOR LOCATIONS OF ALL BLOCK OUTS, INSERTS, OPENINGS, CURBS, BASES, & PADS THAT ARE NOT DIMENSIONED OR SHOWN ON CONTRACTOR'S DWG'S. OR STRUCTURAL DWG'S.4. STRUCTURAL STEEL, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION PLANS AND SPECIFICATION SHALL BE PROVIDED AND ARE THE RESPONSIBILITY OF THERE RESPECTIVE SUBCONTRACTORS IF NOT CARRIED IN ARCHITECTURAL SERVICES5. ALL CONSTRUCTION SHALL CONFORM TO AND BE IN ACCORDANCE WITH THE REGULATOR REQUIREMENTS MANDATED BY ALL FEDERAL, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION IN ACCORDANCE TO THE STATE IN WHICH THE WORK IS PERFORMED (STATE BUILDING CODE, STATE LIFE SAFETY & FIRE CODE ETC.)6. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS, AND SHALL CONFIRM WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC. SHALL BE IMMEDIATELY REPORTED IN WRITING TO THE ARCHITECT FOR CLARIFICATION7. DIMENSIONS ARE FROM EXTERIOR FACE OF FOUNDATION, VENEER, OR WALL STUD AND TO CENTER OF ALL INTERIOR STUD WALLS OR FACE OF INTERIOR MASONRY. UNLESS NOTED OTHERWISE.8. CLEAR DIMENSIONS ARE FROM FACE TO FACE OF WALL FINISH. UNLESS NOTED OTHERWISE9. REFER TO MECHANICAL DRAWINGS / SPEC. FOR ALL SIZES AND LOCATIONS OF MECHANICAL DUCT WORK.10. UNLESS OBVIOUSLY SHOWN OTHERWISE, DOOR LOCATIONS NOT DESIGNATED BY WRITTEN DIMENSION SHALL BE CENTERED IN THE WALL OR SHALL BE LOCATED FOUR (4) INCHES FROM FINISH WALL TO EDGE OF DOOR JAMB. PER PLAN.11. PROVIDE METAL CORNER BEAD AT ALL OUTSIDE CORNERS OF PLASTERED OR DRYWALL SURFACES, UNLESS NOTED OTHERWISE.12. PENETRATIONS OF ALL FIRE RATED ASSEMBLIES SHALL BE PROTECTED BY LIKE RATED CONSTRUCTION DAMPERS, SEALANTS, COLLARS, ETC., TYPICAL.13. CONTRACTOR SHALL FURNISH, LOCATE AND INSTALL ALL ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING AND ELECTRICAL WORK, FIRE RATED AS REQUIRED.14. FURNISH AND INSTALL SOLID BLOCKING BEHIND ALL WALL HUNG MILLWORK ITEMS, RAILS, FIXTURES,GRAB BARS, ETC. . WHERE INDICATED OR REQUIRED.15. CONTRACTOR SHALL LAYOUT OR MARK, ALL EQUIPMENT, SYSTEMS AND MILLWORK ON THE FLOOR FOR ARCHITECT OR OWNER'S APPROVAL PRIOR TO BEGINNING CEILING / OVER HEAD WORK.16. ALL SPRINKLER HEAD LOCATIONS, MAINS, BRANCHES AND RISER PIPE LOCATIONS MUST BE COORDINATED WITH THE DESIGN / BUILD CONTRACTOR PRIOR TO WORK.17. FURNISH AND INSTALL FIRE EXTINGUISHERS IN TYPE, QUANTITY, AND LOCATION PER LOCAL FIRE DEPARTMENT. TYPICAL18. CONTRACTOR SHALL VERIFY, COORDINATE LOCATION WITH THE ARCHITECT ANY SMOKE, CARBON MONOXIDE DETECTOR OR FIRE ALARM DEVICE AS REQUIRED BY THE LOCAL FIRE DEPARTMENT.19. FURNISH & INSTALL FIRE DAMPERS WITH FUSIBLE LOUVER WHEREVER DUCT WORK PENETRATES ONE OR TWO HOUR CEILINGS OR WALLS. TYPICAL UNLESS NOTED OTHERWISE.20. PROVIDE PLASTER AND GYPSUM WALL BOARD CONTROL JOINTS AT 30'-0" ON CENTER FROM FLOOR TO CEILING, OR AS NOTED ON THE CONSTRUCTION DOCUMENTS. VERIFY IN FEILD WITH ARCHITECT PRIOR TO WORK.GENERAL NOTES:LOCUS MAP:SHEET NUMBER(N.T.S.)MASTER ABBREVIATION KEY:254 Drake Hill Rd. Strafford, NH TW-Designs.com | 603.664.2181BREEZELINE UNCASVILLE CT689 Old Colchester Rd.Uncasville, CT12/13/22 (N.F.C.)PCSPROJECTCOVER SHEET2204430% PROGRESS SETAB ANCHOR BOLTAC AIR CONDITIONERACI AMERICAN CONCRETEINSTITUTEACOUST ACOUSTICAFF ABOVE FINISH FLOORALT ALTERNATEALUM ALUMINUMANCH ANCHORANOD ANODIZEDASTM AMERICAN SOCIETY FORTESTING MATERIALSBD BOARDBIT BITUMINOUSBL BUILDING LINEBLDG BUILDINGBLK BLOCKBLKG BLOCKINGBM BEAMBOC BOTTOM OF CURBBOF BOTTOM OF FOOTINGELEVATIONBOT BOTTOMBRG BEARINGBRK BRICKBSMT BASEMENTBTW BETWEENBUR BUILT-UP ROOFCAB CABINETCB CATCH BASINCER CERAMICCF CUBIC FOOTCI CAST IRONCJ CONTROL JOINTCL CLOSETCLCB CURBLESS CATCH BASINCLG CEILINGCM CONTRACT MANAGERCMU CONCRETE MASONRYUNITCO CLEAN OUTCOL COLUMNCOMP COMPACTED(COMPOSITION)CONC CONCRETECONST CONSTRUCTIONCONT CONTINUOUSCONTR CONTRACTORCORR CORRUGATEDCP CONTROL PANELCSG CASINGCSMT CASEMENTCT CERAMIC TILECTR CENTERCY CUBIC YARDDF DRINKING FOUNTAINDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDL DEAD LOADDN DOWNDR DOORDS DOWNSPOUTDS/C DRIVE SIDE OF CURBDTL DETAILDWG DRAWINGSheet Sheet Name Issued RevisionRevisionDatePCS PROJECT COVER SHEET N.F.C.A1.1 PLAN & REFLECTED CLG PLAN N.F.C.A3.1 EXTERIOR ELEVATIONS N.F.C.A4.1 BUILDING SECTIONS N.F.C.A7.1 ENLARGED RESTROOM AND INT ELEVATIONS N.F.C.E EASTEJ EXPANSION JOINTEJC EXPANSION JOINT COVEREL ELEVATIONELEC ELECTRICALELEV ELEVATOREQ EQUALEQUIP EQUIPMENTER EMERGENCY ROOMEST ESTIMATEEWC ELECTRICAL WATERCOOLEREXH EXHAUSTEXIST EXISTINGEXP EXPANSIONEXPD EXPANDEDEXT EXTERIORF/F FACE OF FOUNDATIONWALLFA FRESH AIRFAP FIRE ALARM PANELFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHERCABINETFIN FINISHFL FLOW LINEFLR FLOORFND FOUNDATIONFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDFR FIRE RATEDFS FULL SIZEFT FOOTFTG FOOTINGFUR FURRED (FURRING)FVC FIRE VALVE CABINETGA GAUGEGALV GALVANIZEDGC GENERAL CONTRACTORGEN GENERALGL GLASSGLZ GLAZINGGRD GRADEGYP GYPSUMH&V HEATING & VENTILATINGHC HANDICAPHDWD HARDWOODHGT HEIGHTHM HOLLOW METALHP HIGH POINTHVAC HEATING, VENTILATION,AIR CONDITIONINGHWH HOT WATER HEATERID INSIDE DIAMETERIN INCHINSUL INSULATIONINT INTERIORINV INVERTJC JANITOR'S CLOSETJST JOISTJT JOINTLAM LAMINATELAV LAVATORYMAS MASONRYMAT MATERIALMAX MAXIMUMMECH MECHANICALMEM MEMBRANEMEP MECHANICAL,ELECTRICAL, PLUMBINGMETTP METAL TOILET PARTITIONMFR MANUFACTURERMH MANHOLEMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMTL METALMULL MULLIONN NORTHNAT NATURALNEC NECESSARYNIC NOT IN CONTRACTNOM NOMINALNRC NOISE REDUCTIONCOEFFICIENTNTS NOT TO SCALEOC ON CENTEROD OUTSIDE DIAMETEROF/C OUTSIDE FACE OFCONCRETEOH OVERHEADOPG OPENINGOPP OPPOSITEOR OPERATING ROOMPBD PARTICLE BOARDPCF POUNDS PER CUBICFOOTPL PROPERTY LINEPLAM PLASTIC LAMINATEPLAS PLASTERPLYWD PLYWOODPNL PANELPSF POUNDS PER SQUAREFOOTPSI POUNDS PER SQUAREINCHPT PAINTPTD PAINTEDPTN PARTITIONPVC POLYVINYL CHLORIDEQT QUARRY TILER RADIUSR/A RETURN AIRRC REINFORCED CONCRETERD ROOF DRAINREF REFERENCEREFR REFRIGERATORREINF REINFORCEREQD REQUIREDRGH ROUGHRL RAIN LEADERRM ROOMRO ROUGH OPENINGROW RIGHT OF WAYRQMT REQUIREMENTS SOUTHS-TRAP SEDIMENT TRAPSC SOLID CORESCED SCHEDULESD STORM DRAINSF SQUARE FOOTSH SHOWERSHT SHEETSIM SIMILARSL SLIDINGSMR SINGLE PLY MEMBRANEROOFSP/PT/FIN SPECIAL PAINT FINISHSPEC SPECIFICATIONSPKR SPEAKERSQ SQUARESS STAINLESS STEELSTA STATIONSTD STANDARDSTL STEELSTOR STORAGESTRG STRINGERSTRUCT STRUCTURALSU SITE UTILITYSUSP SUSPEND (SUSPENDED)SYMM SYMMETRICALSYS SYSTEMT TREADT&G TONGUE & GROOVEDT/FRM TOP OF FRAMET/SLB TOP OF SLABTB TACKBOARDTEL TELEPHONETEMP TEMPORARYTERR TERRAZZOTHK THICKTHLD THRESHOLDTOC TOP OF CURBTOF TOP OF FOUNDATIONTOS TOP OF SLABTOW TOP OF WALL ELEVATIONTR TO REMAINTYP TYPICALUH UNIT HEATERUL UNDERWRITERSLABORATORIES, INC.UOD UNDERSIDE OF DECKUON UNLESS OTHERWISENOTEDUR URINALUV UNIT VENTILATORVAR VARIES OR VARIABLEVB VINYL BASEVCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVIF VERIFY IN FIELDVNR VENEERVOL VOLUMEW WESTW/ WITHWC WATER CLOSETWD WOODWDW WINDOWWGL WIRE GLASSWP WEATHERPROOF(WATERPROOFING)WWF WELDED WIRE FABRICArchitect of Record:T | W Designs, LLC254 Drake Hill Rd.Strafford, NH 03884603-664-2181Civil Engineer:Structural Engineer:Electrical Engineer:Mechanical Engineer:Fire Protection Eng.:General Contractor:XXXProject Info:TBDXXXXXXXXXXXXBreezeline Uncasville, CT689 Old Colchester Rd.Uncasville, CT 06353.Revision ScheduleNo. Description DateSITE
SHELVESSTORAGEWP WPWP WPA3.13A3.1A3.1A3.1241ALTHOUGH NO MOP SINK OR DRINKING FOUNTAIN IS REQUIRED PER IBC. A MOP SINK IS PROVIDED TO AIDE IN WASHING THE VCT FLOORS.ELEC. PL.38' - 0" (OVERALL)32' - 0" (OVERALL)5' - 0"COVERED EXTERIOR ENTRY W/ S.O.G.EXT. WD STUD WALL W/ VINYL SIDING, 2" R-ZIP, R-13 CLOSED CELL SPRAY FOAM INSULATION & 5/8" G.W.B. PTD. VINYL GLIDER WINDOWS, TYPROOF OVER HANG ABV.V.C.T. ON 4" S.O.G.3-5/8" MTL. STUDS INT. WL., TYP.1,216 s.f.8X8 CUBES OR SYSTEM FURNITURE, N.I.C.SIT / STAND TABLE TOPS, N.I.C. TYP (8)CONF. TABLE, N.I.C.EXISTING HEAD ENDADA SHOWER W/ SEAT & HAND WAND.FIXED GLASS INTERIOR WINDOW60X60 EXT. S.O.G., PITCH AWAY FROM BLD.PROVIDE WATER ENTRANCE HERE. PRESSURE TANK ON FL. W/ WATER HEATER MNT. ABV. T.B.D. WALL MOUNTED TVA7.11101102a104105106AA103a103bC102bAAB11112222222226' - 0"6' - 4"4' - 0"4' - 0"5' - 8"12' - 0"22' - 0"10' - 0"21' - 1 1/2"16' - 10 1/2"4' - 10"20' - 6"6' - 8"CONFERENCE103RESTROOM104MOP CLOSET105OPEN WORKSPACE101BREAK AREA102ELEC. RM106REF.2PTWALL MOUNTED TV19' - 7"4' - 11"3' - 6"4' - 0"2' - 5 1/2"7' - 5 3/4"7' - 5 3/4"2' - 2"11' - 8"26' - 4"7' - 2"3' - 2"3' - 6"4' - 10"11' - 10 1/2"7' - 5 1/2"A7.14444Elevation 1 -aElevation 1 -aElevation 1 -aROOF OVER HANG ABV.----1A4.1FLOOR OUTLET TO TV WALL BOX,VIA FLOOR CONDUIT. TYP. @ 2 LOC.A3.13A3.1A3.1A3.12412X2 DROP IN LED LIGHTING, TYP.A.F.F.2' x 2' ACT System9' - 0"R.C.P. NOTES:1. HVAC GRILLS & THEIR LOCATIONS T.B.D.2. HVAC SLIM PACKAGE UNIT SHALL BE HUNG FROM THE BOT. OF ROOF TRUSS @ 11'-6", ABOVE THE A.C.T. @ 9'-0"3. BOT. OF ROOF TRUSS SHALL BE SHEATHED W/ ONE LAYER OF 5/8" G.W.B. FOR PURPOSE OF AIT INFILTRATION.4. R-49 BLOWN IN INSULATION IN TRUSS CAVITY.5. PROVIDE SCUTTLE HOLE IN G.W.B. TO ACCESS TRUSS CAVITY. VENTED SOFFIT, TYP.A7.14444Elevation 1 -aElevation 1 -aElevation 1 -a----1A4.1A.F.F.2' x 2' ACT System9' - 0"WALL MOUNTED MINI SPLITBATH EXHUST FAN, TYP. @ (2) LOC.WEATHER PROOF 6" DIA. EXT. REC. CAN LIGHTAPROX LOC. OF SLIM HVAC UNIT ABV. ACT.DUCT TO GRILLS PER MECH DWG'SPROVIDE 24X30 SCUTTLE HOLE INTO TRUSS BAYS ABV.EXTERIOR WALL PACK LIGHTPER ELEC. DWG'SPROVIDE SINGLE LAYER 5/8" G.W.B. LID ATTACHED TO UNDERSIDE OF PRE-ENGINEERED WD ROOF TRUSSES ABV.254 DRAKE HILL RD. STRAFFORD, NHP: 603.664.2181 | F: 603.664.9508Project Info:Sheet Number:JOB NO:SCALE:DRAFTED:CHECKED:Sheet Title:Sheet Status:Latest Release:Issued For:Org. Issue Date:Printed on:12/14/202212/14/2022C:\Users\John\TW-Designs\TW-Designs - Documents\3.Projects\22044 - Breezeline Uncasville CT\22044_A.rvt1/4" = 1'-0"A1.130% PROGRESS SETBREEZELINEUNCASVILLECT689 OldColchester Rd.Uncasville, CT22044JMTCheckerPLAN &REFLECTEDCLG PLAN12/13/22 (N.F.C.)30% PROGRESS SETTruePROJECT NORTHRevision ScheduleNo. Description Date1/4" = 1'-0"1FIRST FLOOR PLAN1/4" = 1'-0"2REFLECTED CEILING PLAN
FIRST FLOOR PLAN100' -0"T.O. FTG.96' -0"1st FL -T.O.W.111' -6"9' - 0"CLAPBOARD SIDINGEXT. WALL PACK, TYP6" / 1'-0"4" 1'-0"4" 1'-0"STANDING SEAM MTL ROOF1A4.1FIRST FLOOR PLAN100' -0"T.O. FTG.96' -0"1st FL -T.O.W.111' -6"9' - 0"1A4.1FIRST FLOOR PLAN100' -0"T.O. FTG.96' -0"1st FL -T.O.W.111' -6"CLAPBOARD SIDINGEXT. WALL PACK, TYP9' - 0"4" / 1'-0"6" 1'-0"6" 1'-0"12' - 1"----FIRST FLOOR PLAN100' -0"T.O. FTG.96' -0"1st FL -T.O.W.111' -6"CLAPBOARD SIDINGEXT. WALL PACK, TYP9' - 0"6" 1'-0"6" 1'-0"8' - 2"----EXTERIOR WALL MOUNTED HVAC CONDENSOR REFER TO MECH DWG'SSTANDING SEAM MTL ROOF254 DRAKE HILL RD. STRAFFORD, NHP: 603.664.2181 | F: 603.664.9508Project Info:Sheet Number:JOB NO:SCALE:DRAFTED:CHECKED:Sheet Title:Sheet Status:Latest Release:Issued For:Org. Issue Date:Printed on:12/14/202212/14/2022C:\Users\John\TW-Designs\TW-Designs - Documents\3.Projects\22044 - Breezeline Uncasville CT\22044_A.rvt1/4" = 1'-0"A3.130% PROGRESS SETBREEZELINEUNCASVILLECT689 OldColchester Rd.Uncasville, CT22044AuthorCheckerEXTERIORELEVATIONS12/13/22 (N.F.C.)30% PROGRESS SETRevision ScheduleNo. Description Date1/4" = 1'-0"1NORTH EXTERIOR ELEVATION1/4" = 1'-0"2SOUTH EXTERIOR ELEVATION1/4" = 1'-0"3EAST EXTERIOR ELEVATION1/4" = 1'-0"4WEST EXTERIOR ELEVATION
FIRST FLOOR PLAN100' -0"T.O. FTG.96' -0"1st FL -T.O.W.111' -6"----WALL MOUNTED TV106AENERGY HEEL1' - 4"OVRHNG2' - 0"32' - 0"OVRHNG2' - 0"6" 1'-0"6" 1'-0"ENERGY HEEL1' - 4"4' - 0"11' - 6"21' - 1" (OVERALL)COUNTINOUS RIDGE VENTSTANDING SEAM MTL ROOF W/ HIGH TEMP SLIP SHEET3/4" T&G ROOF SHEATHINGROOF TRUSS, PER STR ENG.2' - 4"9' - 0" CLG HGT11' - 6" B.O.TRUSSVINYL CLADDING, REFER TO ELEV.R-9 ZIP SYSTEM R-SHEATHING W/ INTEGRATED RIGID INSULATION AND EXT SHEATHING2X6 WD STUD EXT WALLSR-13 CLOSED CELL SPRAY FOAM INSULATION5/8" PTD. GWB4" COVE BASE2X6 P.T. SILL PLATE SET ON SILL SEAL, TYP.REINFORCED CONC FND, PER STR ENGCONC FTG, PER STR ENGR-15 RIGID INSULATION @ PERIMETER OF FNDCONC. SLAB ON GRADE, PER STR ENGUNDERSLAB VAPOR BARRIER PER STR. DWG.12" COMPACTED GRAVEL FILL TO 95" COMPACTION RATEVINYL CLAD WOOD POSTSLAB ON GRADE ENTRY, SLOPED MIN 1/8" AWAY FROM BUILDING8' - 0" B.O.BEAMR-49 BLOWN-IN INSULATION5/8" G.W.B. LID @ UNDERSIDE OF TRUSS254 DRAKE HILL RD. STRAFFORD, NHP: 603.664.2181 | F: 603.664.9508Project Info:Sheet Number:JOB NO:SCALE:DRAFTED:CHECKED:Sheet Title:Sheet Status:Latest Release:Issued For:Org. Issue Date:Printed on:12/14/202212/14/2022C:\Users\John\TW-Designs\TW-Designs - Documents\3.Projects\22044 - Breezeline Uncasville CT\22044_A.rvt1/2" = 1'-0"A4.130% PROGRESS SETBREEZELINEUNCASVILLECT689 OldColchester Rd.Uncasville, CT22044AuthorCheckerBUILDINGSECTIONS12/13/22 (N.F.C.)30% PROGRESS SETRevision ScheduleNo. Description Date1/2" = 1'-0"1SECTION 'A'
TURNING SPACEø 5' - 0"A7.12A7.136' - 5" MIN CLR7' - 2"3' - 2"12' - 5"4' - 11"3' - 6"4' - 0"4' - 6" MIN CLR60"X56" CLR FLR SPACE @ WATER CLOSET18"52"52"X30" CLR FLR SPACE @ LAVATORY36" X 84"104RESTROOM104MOP CLOSET105CONFERENCE103WALL MOUNTED TV36" X 36" CLR SHOWER COMPARTMENT56"X36" CLR FLR SPACE @ SHOWER COMPARTMENT36" EDGE OF REFLECTING SURFACE40" MAX TO BOTTOM34" MAX36" (33"-36")40" (39"-41")18" MIN6" MAX36" MIN42" MIN18"52"24"60" FRP8' - 11 3/4" CLG HGTPTD G.W.B.FRP(17"-19")18"(12" MAX)6"48" (42" MIN)54" MIN40" (39"-41")18" MIN41" (39"-41")8' - 11 3/4" CLG HGT36" (33"-36")FIRST FLOOR PLAN100' -0"254 DRAKE HILL RD. STRAFFORD, NHP: 603.664.2181 | F: 603.664.9508Project Info:Sheet Number:JOB NO:SCALE:DRAFTED:CHECKED:Sheet Title:Sheet Status:Latest Release:Issued For:Org. Issue Date:Printed on:12/14/202212/14/2022C:\Users\John\TW-Designs\TW-Designs - Documents\3.Projects\22044 - Breezeline Uncasville CT\22044_A.rvtAs indicatedA7.130% PROGRESS SETBREEZELINEUNCASVILLECT689 OldColchester Rd.Uncasville, CT22044AuthorCheckerENLARGEDRESTROOMAND INTELEVATIONS12/13/22 (N.F.C.)30% PROGRESS SETRevision ScheduleNo. Description Date1/2" = 1'-0"1ENLARGED RSTRM PLAN1/2" = 1'-0"2RSTRM ELEV 'A'1/2" = 1'-0"3RSTRM ELEV 'B'1/4" = 1'-0"4Elevation 1 - a