HomeMy WebLinkAboutSite planGRID NORTH
C
-336
,334
r• -
/ 334
I / PROPOSED
/ 4 BEDROOM
/ PROPOSED GARAGE / RESIDENCE > WALK -OUT a /
DRIVEWAY Fk. EL. -341.2 I / F.F. EL. -343.2 r _ \
/ / r BSMT-334.2 /
40 r / -
/ r�
/ INV. ORCH / i
333.0 FO TING
r"y D IN
;o PROPOSED
U/G UTfLITIES '
336 /
1,250GAL./2CQMP.
SEPTIC TANK
INV. IN -33 25
/ I 38 z j INV. OU 1,7 2. 0
/ O LET
31LL-4"PVC fl i W
(ASTM D1785) - \ X33
334 r / LIMITS OF /
/ SELECT FILL / o
/ TH#3B \ \ 0
x333.6 / /
00
/ (SEE DE AIL)
]ki#3D
ti
� f i
26LF-4""PVC
i f (SDR35)
INV. TN -331.70 P #
/ Z / /INV. OUT -331.60 / / PROVIDE`A CONTINUOUS LINE
TH#3 / / / / �S OF SILT FENCE THROUGHOUT
/ CONSTRUCTION (SEE DETAIL)
33 PROPOSED 61MITS OF
jfA3C / CLEARING
18'
j C 58LF OF GEOMATl GST -6212
EXISTING GRADE SYSTEM - 331.05 / 40' % I
I BOTTOM OF SYSTEM - 330.60 / / r
TOP
\)
INV. O4" TOP DISTRIBUTION PIPE - 331.60 i (/
MLSS DATA & DESIGN
LOT #49-3
4 BEDROOM RESIDENCE
SLOPE 6.3%
PERC RATE -I" IN 7 MINUTES
RECEIVING SOIL DEPTH (AVG.) 25.75"
(HF) 30 X (FF) 1.75 X (PF) 1.0 = 52.5'
MLSS REQUIRED - 52.5'
MLSS PROVIDED 58'
4 BEDROOM HOUSE REQUIRES 577.5 S.F.
OF EFFECTIVE LEACHING AREA
USE 58 FEET OF GEOMATRIX-GST 6212 (12" DEPTH)
(58 X 10.0 = 580 S.F.)
USE 1,250 GAL, 2 COMPARTMENT SEPTIC TANK
W/ OUTLET FILTER DEVICE
TEST HOLE DATA
WITNESSED BY MICHAEL KIRBY
UNCAS HEALTH DISTRICT - 8/29/19, 8/30/19 & 10/24/19
TH#3A - 0"-10" TOPSOIL
- 10"-24" SUBSOIL
- 24"-76" COMPACT SAND W/SILTS, ROCK
NO WATER, MOTTING@24", NO LEDGE
ROOTS TO 19", RESTRICTIVE - 24"
TH#3B - 0"-9" TOPSOIL
- 9"-28" SUBSOIL
28"-81" FIRM SAND SOME SILT, STONES
NO WATER, MOTTING@28", NO LEDGE
ROOTS TO 41", RESTRICTIVE - 28"
TH#3C - 0"-8" TOPSOIL
8"-25" SUBSOIL
25"-76" FIRM SAND SOME SILT, STONES
NO WATER, MOTTING@25", NO LEDGE
ROOTS TO 25", RESTRICTIVE - 25"
TH#3D - 0"-8" TOPSOIL
- V-26" SUBSOIL
26"-84" FIRM SAND SOME SILT, STONES
NO WATER, MOTTING@26", NO LEDGE
ROOTS TO 30", RESTRICTIVE - 26"
2X2 5/8 16 GA. WIRE MESH7 I
1 1/2"
o v
M
N "�2
STANDARD D -BOX
NOT TO SCALE
FILTER
KNOCKOUT INLET AND
OUTLET OPENINGS !
FABRIC
�
e 3"
LIQUID LEVEL
ANGLE 10' UP SLOPE
POST
FOR STABILITY AND
%Qp SELF CLEANING
li�w
COMPACTED
'.
�T
BACKFILL
-
-- - NOT TO SCALE
A
ASTM C-33 SAND SPECIFICATIONS:
SIEVE SIZE PERCENT PASSING
0.375"100
#4 95.100
#8 80-100
#16 50-85
#30 25-60
#50 5-30
#100 <10
#200 <5
m
PERC TEST DATA
PERFORMED BY ADVANCED SURVEYS, LLC - 8/29/19, 8/30/19 & 10/24/19
PERC #3
DEPTH - 23"
PRESOAK -10:00
10:45.3 1/2"
10:55-9"
11:05 -121/2"
11:15-15"
11:25-171/4"
11:35 -19"
11:45 - 20 1/4"
PERC RATE - 7 MINUTES PER INCH
CAST
CONCRETE COVERS
PLAN
CAPACITIES A B C
1250 GAL 61" 1 51" 48"
1500 GAL 6FT5T 56"
4 x 4 12.6/12.6 GA. WIRE MESH17 1/2" 6 x 6 6/6 GA. WIRE MESH
KNOCKOUT INLET AND
OUTLET OPENINGS !
0
!'
e 3"
LIQUID LEVEL
fV
CONTINUOUS HOT P
ASPHALTSEAL
" SCHED. 940
i
a
CAST
CONCRETE COVERS
PLAN
CAPACITIES A B C
1250 GAL 61" 1 51" 48"
1500 GAL 6FT5T 56"
4 x 4 12.6/12.6 GA. WIRE MESH17 1/2" 6 x 6 6/6 GA. WIRE MESH
OUTLET
OUTLET
FILTER
U DEVICE
CROSS SECTION
1250/1500 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
FINISH GRADE TO
DIRECT RUNOFF AWAY
6" MIN.
COVER FILTER FABRIC
OVER /
LLIAMTM C-33 ► ;®
41 .•
DOT #6 STONE ASTM C-33 SAND
41STRIBUTION PIPE CROSS SECTION A -A
FILTER FABRIC
1�
•C .. . . .�_.� . . .. . . .. . . .. .:
\ \- CT DOT #6 STONE
`ASTM C-33 SAND
CROSS SECTION B -B
GEOMATRIX GST LEACHING SYSTEM
LEGEND:
F.F. FIRST FLOOR
EL. ELEVATION
S.F. SQUARE FEET
TYP. TYPICAL
[PIN IRON PIN
REC. RECOVERED
�£n5!'-`;ung"�r,�q 1\11111l1fllll
x342.5 EXISTING SPOT ELEVATION
0PAF CO
x336.5 PROPOSED SPOT ELEVATION ��R" j '/' �f& `��`.��P - SF
- - 336 - EXISTING CONTOURS D BE IE THIS MAP IS SUBSTANTIALLY CORRECT
336 PROPOSED CONTOURS ti t: 1IAR
` AS NQT ObT=T. AP IS OT VALID WITHOUT A LIVE SIGNATURE
a
fa-4D SSE'D S L F H SURVEYOR HEREON,
BUILDING SETBACK LINEt
. p,� 511/2021 .;�s Fv
TEST HOLE ((
# 1 # p '��
ENGINEER DATE RIC HARD,d.11BEMS CHAMPS L.S.#70019 TE
DESIGN NOTES:
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
DRIVEWAY AND SEPTIC SYSTEM.
2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED.
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION.
7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE NOTES
PER 1000 S.F.
STRAW/HAY 70-90 lbs. FREE FROM WEEDS
AND COARSE MATTER
WOOD CHIPS 185-275 lbs. FREE OF COARSE MATTER
AIR DRIED, TREAT WITH
PLANTING SCHEDULE: 12lbs NITROGEN / TON
SEEDING DATES:
APRIL I ------ JUNE 15
AUGUST 1---- - SEPTEMBER 15
SEED MIXTURE:
45% RED FESCUE
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN,
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND
TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE.
C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA:
SIEVE SIZE: #4 #10 #40 #100 #200
%PASSING: 100 70.100 **10.50 0.20 0.5 WET SIEVE
%PASSING: 100 70.100 10-75 0-5 0.2.5 DRY SIEVE
** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%,
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT,
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA
AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK•DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
1. CONSTRUCTION SEQUENCE:
A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA.
B. PLACE SELECT FII L IF REQUIRED.
C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE.
D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS
WITH EROSION CONTROLS UNTIL FIRST MOWING.
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL.
3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN
STONE ON COMPACTED SUBGRADE.
5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75" OF THE PROPOSED WELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4
STONE:
SIEVE SIZE PERCENT PASSING (BY WEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
1 -INCH 2O-55
3/4 -INCH 0-10
3/8 -INCH 0-5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE
FIELD BY A LICENSED LAND SURVEYOR.
8, THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 6" INTO EXISTING GRADE.
NOTES:
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS.
2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT.
3. BASE FOR LEVELS: PER REFERENCE MAP.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-40.
5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6. TOTAL AREA OF PROPERTY - 44,970 S.F.f (1.03 ACRES f).
7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION.
REFERENCE MAP:
SUBDIVISION PLAN PREPSARED FOR JWR ASSOCIATES, 234 SIMPSON LANE,
MONTVILLE, CONNECTICUT, SCALES: AS NOTED, DATE: 8/24/19, REV. TO 3/10/20,
ALL SHEETS, PREPARED BY ADVANCED SURVEYS, LLC.
1
INLE
m
!'
e 3"
LIQUID LEVEL
VENT-
CONTINUOUS HOT P
ASPHALTSEAL
" SCHED. 940
i
OUTLET
OUTLET
FILTER
U DEVICE
CROSS SECTION
1250/1500 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
FINISH GRADE TO
DIRECT RUNOFF AWAY
6" MIN.
COVER FILTER FABRIC
OVER /
LLIAMTM C-33 ► ;®
41 .•
DOT #6 STONE ASTM C-33 SAND
41STRIBUTION PIPE CROSS SECTION A -A
FILTER FABRIC
1�
•C .. . . .�_.� . . .. . . .. . . .. .:
\ \- CT DOT #6 STONE
`ASTM C-33 SAND
CROSS SECTION B -B
GEOMATRIX GST LEACHING SYSTEM
LEGEND:
F.F. FIRST FLOOR
EL. ELEVATION
S.F. SQUARE FEET
TYP. TYPICAL
[PIN IRON PIN
REC. RECOVERED
�£n5!'-`;ung"�r,�q 1\11111l1fllll
x342.5 EXISTING SPOT ELEVATION
0PAF CO
x336.5 PROPOSED SPOT ELEVATION ��R" j '/' �f& `��`.��P - SF
- - 336 - EXISTING CONTOURS D BE IE THIS MAP IS SUBSTANTIALLY CORRECT
336 PROPOSED CONTOURS ti t: 1IAR
` AS NQT ObT=T. AP IS OT VALID WITHOUT A LIVE SIGNATURE
a
fa-4D SSE'D S L F H SURVEYOR HEREON,
BUILDING SETBACK LINEt
. p,� 511/2021 .;�s Fv
TEST HOLE ((
# 1 # p '��
ENGINEER DATE RIC HARD,d.11BEMS CHAMPS L.S.#70019 TE
DESIGN NOTES:
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
DRIVEWAY AND SEPTIC SYSTEM.
2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED.
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION.
7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE.
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE NOTES
PER 1000 S.F.
STRAW/HAY 70-90 lbs. FREE FROM WEEDS
AND COARSE MATTER
WOOD CHIPS 185-275 lbs. FREE OF COARSE MATTER
AIR DRIED, TREAT WITH
PLANTING SCHEDULE: 12lbs NITROGEN / TON
SEEDING DATES:
APRIL I ------ JUNE 15
AUGUST 1---- - SEPTEMBER 15
SEED MIXTURE:
45% RED FESCUE
45% KENTUCKY BLUE GRASS
10% PERENNIAL RYE
1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN,
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND
TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE.
C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA:
SIEVE SIZE: #4 #10 #40 #100 #200
%PASSING: 100 70.100 **10.50 0.20 0.5 WET SIEVE
%PASSING: 100 70.100 10-75 0-5 0.2.5 DRY SIEVE
** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%,
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT,
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA
AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND
SPREAD AND COMPACTED WITH TRACK•DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
1. CONSTRUCTION SEQUENCE:
A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA.
B. PLACE SELECT FII L IF REQUIRED.
C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE.
D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS
WITH EROSION CONTROLS UNTIL FIRST MOWING.
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL.
3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED.
4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN
STONE ON COMPACTED SUBGRADE.
5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75" OF THE PROPOSED WELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4
STONE:
SIEVE SIZE PERCENT PASSING (BY WEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
1 -INCH 2O-55
3/4 -INCH 0-10
3/8 -INCH 0-5
7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE
FIELD BY A LICENSED LAND SURVEYOR.
8, THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 6" INTO EXISTING GRADE.
NOTES:
1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING
STANDARDS.
2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT.
3. BASE FOR LEVELS: PER REFERENCE MAP.
4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-40.
5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
6. TOTAL AREA OF PROPERTY - 44,970 S.F.f (1.03 ACRES f).
7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION.
REFERENCE MAP:
SUBDIVISION PLAN PREPSARED FOR JWR ASSOCIATES, 234 SIMPSON LANE,
MONTVILLE, CONNECTICUT, SCALES: AS NOTED, DATE: 8/24/19, REV. TO 3/10/20,
ALL SHEETS, PREPARED BY ADVANCED SURVEYS, LLC.