Loading...
HomeMy WebLinkAboutSite PlanRIGHT OF WAY TO FTCH HILL ROAD ZONING COMPLIANCE TABLE - R-80 DISTRICT(CLUSTER) ITEM REQUIRED PROPOSED LOT AREA 40,000 S.F. 51,681 SF +/- LOT FRONTAGE 135 FT. 135.54' FRONT YARD 37.5 FT. 45.0' SIDE YARD 15 FT. 37.5' REAR YARD 37,5 FT. 290'+ BUILDING HEIGHT 35 FT. 26 FT. IPI ryh� G �pp0 /l RE 4� PROVIDE NON -TRACKING w� CONSTRUCTION ENTRANCE (TYP.) (SEE DETAIL) \ I 0 2 LEGEND: F.F. EL. S.F. DH IPIN REC. x255.6 x248.5 - - 246 -- - -i 246--- F` _ P � ^. F MUMo- o �`. o o .G GOVC�/ OGOGO ',)O•J J O O .252 00o000" \\ \ CONSTRUCTION ENTRANCE PROPOSED.� x255.6 ^4 CLEARING \ \\ NOT TO SCALE LIMITS I\ \ \ / / A&e FOOTING / PROPOSE C)CC4' Q r i DRAIN .. / UTILITIES ` �r?�i ` / / Q4��4�ti 'OUTLET \ VSO 4g ti h C PROPOSED 44�g"� 35LF-4"PVC WELL ,�.� • 253,50 (ASTM D1785) 1,250 (2COMP.) SEPTIC TANK- '' , INV. IN -247.75 U -_ � ' ' TNV.'OUT-247.50 / ----- -_ _ - / (SEE DETAIL) �✓ \ _ h� D -BOX ti? _ INV. IN Zer 9.2x _ - \ 248 INV _OUT 1147.10 'Po 5LF-4"PVC i o (SDR -35) 4 42LF OF GEOMATRIX GST -6218100' / / EXISTING GRADE @SYSTEM .248.0 / / / i' / INSTALL A CONTINUOUS \ BOTTOM OF SYSTEM - 245.50 i 4 LINE OF SILT FENCE- - - - / / /S�/ /�D� TP#2D . .--\ (SEE DETAIL) TOP OF SYSTEM - 247.00 r / /" pT *, x'' Z3� INV. 4" TOP DISTRIBUTION PIPE - 247.00 �� tih \ "ell ' / ® �� � / - ' (ADDITIONAL TESTHOLES REQUIRED) / TP#2A / TP#2C \ _ - r LIMITS OF INLAND WETLANDS I (PER REFERENCE MAP) \\ I J / \ FIRST FLOOR ELEVATION SQUARE FEET DRILL HOLE IRON PIN RECOVERED EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION EXISTING CONTOURS PROPOSED CONTOURS BUILDING SETBACK LINE TEST HOLE SOIL TEST DATA WITNESSED BY DAVID COUGHLIN UNCAS HEALTH DISTRICT - 7/2005 TH#2A - 0"-12" TOPSOIL - 12"-57" BROWN SANDY LOAM - 57"-74" GRAY COMPACT SANDY TILL NO WATER, MOTTING@57", NO LEDGE TH#2B - 0"-23" TOPSOIL - 23"-61" BROWN SANDY LOAM 61 "-82" GRAY MEDIUM COMPACT SANDY TILL NO WATER, NO MOTTING, NO LEDGE TH#2C - 0"-11" TOPSOIL 11 "42" BROWN FINE SANDY LOAM - 42"-88" GRAY COMPACT SANDY TILL NO WATER, MOTTING@42", NO LEDGE TH#2D - 0"-7" TOPSOIL - 7"-34" BROWN SANDY LOAM - 34"-51" GRAY FINE SAND - 51 "-86" GRAY MEDIUM SOMPACT SAND & SILT WITH POCKETS OF GRAVEL NO WATER, NO MOTTING, NO LEDGE N ASTM C-33 SAND SIEVE SIZE PERC 0.375" 100 #4 95-100 4880,100 #16 50-85 #30 25-60 #50 5,30 #100 <10 A U N kSTM C-33 SAND PERC TEST DATA (PER REFERENCE MAP) PERC #2 DEPTH - 30" PRESOAK - 0.60/HR 10:22 -13 3/4" 10:27 -18" 10:32 - 22" 10:37 - 24" 10:42 - 26" 10:47 - 28" 10:52 - DRY PERC RATE - 2.5 MINUTES PER INCH MLSS & DESIGN DATA 4 BEDROOM RESIDENCE PERC RATE - 1 TO 10 MIN. SLOPE - 12.5% AVG. RESTRICTIVE DEPTH - 49" (BF)18 x (FF)1.75 x (PF)1.0 = 31.5' MLSS REQUIRED - 31.5' MLSS PROVIDED - 42' 4 BEDROOM HOUSE REQUIRES 577.5 S.F. OF EFFECTIVE LEACHING AREA USE 42 FEET OF GEOMATRIX-GST 6218 (18" DEPTH) (42 X 14.0 = 588 S.F.) USE 1,250 GAL. 2 COMPARTMENT SEPTIC TANK W/ OUTLET FILTER DEVICE FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM i 6" MIN. COVER FILTIR FABRIC OVER `- CT DOT #6 STONE 'T DOT #6 STONE ASTM C-33 SAND CROSS SECTION A -A DISTRIBUTION PIPE X11 V I X11 6" MIN. FII,. - -- - H = 6" (GST 6206) 12" (GST 6212) 18" (GST 6218) 24" (GST 6224) 30" (GST 6230) 36" (GST 6236) CROSS SECTION B -B GEOMATRIX GST LEACHING SYSTEM ONE 2X2 5/816 GA. WIRE MESH 11/2" � 10'-6" l KNOCKOUT INLET AND OUTLET OPENINGS J L M � t iv 2" - CAST CONCRETE COVERS PLAN STANDARD D -BOX NOT TO SCALE CAPACITIES A B C 1250 GAL 61" 51" 48' 1500 GAL 69" 59" 54" 4 x 412.6/12.6 GA. WIRE MESH 17 1/2" 6 x 6 6/6 GA. WIRE MESH LIQUID LEVEL- C CONTINUOUS HOT D FILTER cq ASPHALT SEAL FABRIC I " SCHED. #40 Ml ANGLE 10" UP SLOPE 1 POST FOR STABILITY AND SELF CLEANING - .. •T-` • • -`� •' " *- CROSS SECTION COMPACTED N BACKFILL a 1250/1500 GALLON 2 COMPARTMENT SILT FENCE SEPTIC TANK NOT TO SCALE NOT TO SCALE PROJECT I DRAWN B DATE: SCALE: SHEET F \``ttttt1111t71f 71ffff�''� OF CO,!VI, TO .B EF, S IS SUBSTANTIALLY CORRECT AS S(TI' N. IS P N VA ID WITHOUT A LIVE SIGNATURE AND T Y E 0 I F T ES YOR HEREON. 2'7 kr 15 RICH.AI . 'WER L.S• #70019 DATE 3�i f' 1111111/1 .• U EROSION AND SEDIMENT CONTROL PLAN: I. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE. 4• ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAW/HAY 70-90 lbs, FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 lbs. FREE OF COARSE MATTER AIR DRIED, TREAT WITH PLANTING SCHEDULE: 121bs NITROGEN / TON SEEDING DATES: APRIL 1------- JUNE 15 AUGUST 1------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN• 2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED. LEACHING SYSTEM CONSTRUCTION NOTES: 1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING, FILL MATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES. B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE. C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA: SIEVE SIZE: #4 #10 #40 #100 #200 %PASSING: 100 70.100 **10.50 0.20 0.5 WET SIEVE %PASSING: 100 70-100 10-15 0.5 0-2.5 DRY SIEVE ** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. 2• DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT, 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED. SEPTIC SYSTEM CONSTRUCTION NOTES: 1. CONSTRUCTION SEQUENCE: A STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA, B. PLACE SELECT FILL IF REQUIRED. C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE, D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING, 2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL. 3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. 5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M,01.01 FOR NO.4 STONE: SIEVE SIZE_ PERCENT PASSING (BY WEIGHT) 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 2O-55 3/4 -INCH 0-10 3/8 -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR. 8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 30" INTO EXISTING GRADE. NOTES: 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT, 3. BASE FOR LEVELS: N.A.V.D.1988. 4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-80 (CLUSTER DEV.) 5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES, 6. TOTAL AREA OF PROPERTY - 51,681 S.F.+ (1,19 ACRES). 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION. REFERENCE MAP: PLAN SHOWING MCNAUGHT RESUBDIVISION PROPERTY OF WARREN F. MCNAUGHT, FITCH HILL ROAD, MONTVILLE, CONNECTICUT, SCALE: 1 "=40', DATE: SEPTEMBER 2005, REV. TO 5/17/2005, PREPARED BY DIETER & GARDENER.