Loading...
HomeMy WebLinkAbout22SITE2 DRAINAGE Plan Sheet C-3.1 Rev 030822Job Number: Job Start Date: Checked By: Sheet Title: Drawn By: Sheet Number: Scale: 1/4/22 FE22-1700 THIS DRAWING IS THE PROPERTY OF THE ENGINEER. IT HAS BEEN SPECIFICALLY PREPARED FOR THE OWNER FOR THIS PROJECT AT THIS SITE AND IS NOT TO BE USED FOR ANY OTHER PURPOSE, LOCATION OR OWNER WITHOUT WRITTEN CONSENT OF THE ENGINEER.PREPARED FOR245 NORWICH-NEW LONDON ROAD (RT 32)22 UNIT CONDOMINIUM DEVELOPMENTD.R.R.J.E.Q.WESTERN GROUP, LLCSubmission 01/25/22 525 JOHN STREET BRIDGEPORT, CT. 06604 Office (203) 333-9465 fax (203) 336-1769 e-mail Info@FullerSurveyors MONTVILLE, CONNECTICUTAPPROVED BY THE MONTVILLE PLANNING AND ZONING COMMISSION CHAIRMAN DATE WILTON'S WAYO:\Fuller CAD Files\CT\Bridgeport\Benson Terrace\#26 - FE13-1101 - Fox\Survey Data\2013 09 10 FE 13-1100 FOX 26BENSON TERR\LOCATION.crd4/15/2022 12:47 PMStaff Comments 03/08/22 APPROVED BY THE MONTVILLE INLAND WETLAND COMMISSION CHAIRMAN DATE EXPIRATION DATE SEC PLAN APPROVAL DATE NOTES: 1.THIS PLAN IS FOR THE PROPOSED GRADING AND DRAINAGE FOR THE CONSTRUCTION OF A RESIDENTIAL DEVELOPMENT WITH PARKING, AND MISCELLANEOUS LANDSCAPING ALONG THE CT ROUTE 32. THIS PLAN IS NOT TO BE USED AS A SITE OR CONSTRUCTION PLAN. ADDITIONAL DESIGN AND DETAILS REQUIRED FOR BIDDING AND CONSTRUCTION. 2.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 3.THE CONTRACTOR SHALL LOCATE AND VERIFY THE SIZE, LOCATION, DEPTH AND INVERTS OF ANY AND ALL EXISTING UTILITIES PRIOR TO COMMENCING OPERATIONS. THE CONTRACTOR SHALL ALSO BE REQUIRED TO CONTACT THE TOLL FREE "CALL-BEFORE-YOU-DIG" PHONE NUMBER AT 1-800-922-4455. 4.THE PROPOSED DEVELOPMENT SHOWN HEREON WILL REQUIRE REVIEW AND APPROVAL BY THE MONTVILLE BUILDING DEPARTMENT. 5.ALL WORK PERFORMED BY THE OWNER / DEVELOPER MUST INCLUDE IMPLEMENTATION OF AN APPROVED SOIL EROSION AND SEDIMENTATION PLAN IN ACCORDANCE WITH PUBLIC ACT No. 83-388 [PASSED BY THE CONNECTICUT GENERAL ASSEMBLY]. THE OWNER / DEVELOPER SHALL BE THOROUGHLY FAMILIAR WITH THE 2002 CONNECTICUT EROSION & SEDIMENTATION GUIDELINES. 6.RESTORE ALL DISTURBED AREAS WITH A MINIMUM OF FOUR (4") INCHES OF TOPSOIL, SEED, AND HAY MULCH UPON COMPLETION OF CONSTRUCTION. 7.LOT SERVED BY TOWN SEWER SYSTEM AND PUBLIC WATER SUPPLY. 8.ALL EXISTING UTILITY LINES THAT WILL BE DISCONNECTED MUST BE CAPPED OR TERMINATED ACCORDING TO THE TOWN OF MONTVILLE AND UTILITY COMPANY STANDARDS. 9.FINAL RETAINING WALL SYSTEM TO BE DESIGNED AND INSPECTED BY A CONNECTICUT LICENSED ENGINEER. STRUCTURAL DETAILS TO BE SUBMITTED TO THE SATISFACTION OF THE TOWN ENGINEER PRIOR TO ISSUANCE OF BUILDING PERMIT. 10.SEE APPENDIX "O" OF THE ENGINEERING REPORT FOR OPERATION AND MAINTENANCE PLAN. TEST PIT AND PERCOLATION DATAMAP REFERENCES: A."ZONING IMPROVEMENT LOCATION AND TOPOGRAPHIC SURVEY", DATED 7 JANUARY 2022, SCALE 1"=20', BY FULLER ENGINEERING AND LAND SURVEYING, LLC. EARTHWORK A.TOTAL AREA OF DISTURBANCE: 66,340 S.F. (1.5 A.C.±) OFF-SITE WETLANDS FLAGGED BY ALEKSANDRA MOCH ON FEBRUARY 12, 2022. 4 5 45 5 0 5 0 5 5 55 606065657 0 707575 4 2 4 2 4 2 4 3 4 3 4 4 44 4 6 46 4 7 47 4 8 4 8 4 9 4 9 5 1 515 2 52 5 3 5 3 54 5 4 5 6 5 6 57575 85859596161626263636464666667676868696971717272737374747676 4 5505 5 6 0657075 4 4 4647 4 849515253545 6 5 7 5 8 5 9 6 1 6 2 6 3 6 466676869717273747 677 EXTG. HOUSENORWICH-NEW LONDONROAD (CT ROUTE 32)EXTG. HOUSE EXTG. GARAGE EXTG. HOUSE Extg. 12" Water Main (92 PSI Static) Extg. 6" San Sewer 9.2' Deep (El. 67.8±) Extg. 6" San Sewer 9.0' Deep (El. 68.0) Extg. 1" Water to House Extg. Hydrant Approximate Wetlands Limit per DEP Wetlands 2011 50' Upland Review Area SNET 2749 BIT.CONC. APRON PARCEL AREA 79,607 S.F. 1.83 AC WOODED AREA 48" TREE EXIST ING TREEL INE R 2 0 ZO N E R20 ZONE C-1 ZONE C- 1 ZON E C - 1 Z O N E BENCHMARK HELD EXTG NAIL FND IN POLE ELEV. = 77.4 111213141516171819202122 10 987654321 97 LF 8" Ø SCH 80 PVC @0.01 MIN 90 LF 10" Ø SCH 80 PVC @0.01 ft./ft. MIN 84 LF 10" Ø SCH 80 PVC @0.03 ft/ft47 LF 8" Ø SCH 80 PVC @ 0.01 M IN 32 - 4 x 8 x 4' PRE-CAST CONCRETE GALLEY'S 4 ROWS x 8 GALLEYS PER ROW BOT. ELEV. = 58.83' 12" INV. ELEV. = 63.67' EMBEDDED IN 1" BROKEN / CLEAN STONE 66.0' x 18.60' x 5.17' DEEP BOT. STONE ELEV. = 58.33' 28 - 4 x 8 x 4' PRE-CAST CONCRETE GALLEY'S 4 ROWS x 7 GALLEYS PER ROW BOT. ELEV. = 63.67' 10" INV. (IN) = 68.65' 12" INV. OUT = 68.50' EMBEDDED IN 1" BROKEN / CLEAN STONE 58.0' x 18.60' x 5.17' DEEP BOT. STONE ELEV. = 63.17' 96 LF 12" Ø RCP @ 0.08 slope BOT. ELEV. (GALLEYS) = 63.67' CB3 TF = 70.60' 10" RCP INV. = 68.60' (7 LF @ 0.005 ft/ft) CB2 TF = 74.60' 8" PVC INV. = 69.60' (97 LF @ 0.01 ft/ft) CB1 TF = 74.40' 8" PVC INV. = 70.07' (47 LF @ 0.01 ft/ft) CB4 TF = 66.90' 10" RCP INV. = 63.83' (16 LF @ 0.01 ft/ft to GALLEYS) 16 LF 10" S C H 80 PVC CB5 TF = 63.60' 10" PVC INV. = 61.15' 10" RCP (OUT) = 60.91' (12 LF @ 0.02 ft/ft to GALLEYS)12 LF 10" SCH80 PVCSTORM MH (DROP MH) TF = 64.50' 12" RCP INV. (IN) = 61.16' 12" RCP INV. (OUT) = 52.00' LEVEL SPREADER TOP = 52.5 INV. = 49.5 18"Ø OBSERVATION PORT (TYP) 18"Ø OBSERVATION PORT (TYP) W W W W W WWETC ETC ETC ETC W W W W W W W W W W W W W W W W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM W W W W W W W W