HomeMy WebLinkAboutLighting Plan RevRECEIVING AREA
LIGHTS MOUNT
10'-12' AFF.
GALVANIZED STEEL 4"x4"
JUNCTION BOX WITH COVER
ON BOX AS REQUIRED.
CONDUIT. HOLD TIGHT
TO STRUCTURE.
HANGER WIRE REQUIRED ON
BOTH ENDS OF FIXTURE, BY
ELECTRICAL CONTRACTOR.
POWER CORD.
LENGTH VARIES.
COORDINATE UNISTRUT
SUB STRUCTURE TO
SUPPORT LIGHTS.
WIRING ADAPTER PLATE.
A
B-11
B-9E
B-16
E
B-16
A
A
A
A
NL
LIGHTING PLAN1
E2 SCALE: 1/8" = 1'-0"
FIXTURE MOUNTING DETAIL
TYPICAL LED
2
E2 SCALE: 1/8" = 1'-0"
EMERGENCY/EXIT SIGNS AND LIGHTS:
INSTALL EMERGENCY LIGHTS & EXIT SIGNS (CENTERED AT 10'-6"
AFF TO BE ABOVE FIXTURES & MERCHANDISE) THROUGHOUT
THE BLDG. IN COMPLIANCE WITH ALL APPLICABLE CODES.
COORDINATE BUILDING SIGN SIZE WITH DOLLAR GENERAL SIGN
DEPARTMENT BY EMAILING TO SIGNAGE@DOLLAR GENERAL.COM.
WIRE ON CIRCUIT B-23. LOCATE BOX HIGH ON WALL 12' LEFT FROM
CENTER OF BUILDING FOR 26' SIGNS & 16' LEFT FROM CENTER OF
BUILDING FOR 33' SIGNS. SEE ELEVATIONS.
A A
AA
AA
A
A A
A
A
A
A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A A A
A
A
A
A
A A
A
A
A
A
A
AA
A
A
A A
A
A
A
NL
NL
D
B/16
B-5
A
A
A
F
B/9
B-7
F
B-3
B-1
D
B-16
B-3
E
B-16
D
B-3
B
B
B
B
$
$
$
A
LEDS LIGHT FIXTURE SCHEDULE
SYMBOL TYPE MANF.PART #DESCRIPTION W
A ETI 54573161
4' LED FIXTURE
AERIAL MOUNT INCLUDES
(2) 8 FT CABLES
45
A1 ETI 54573161 4' LED FIXTURE
SURFACE MOUNT 45
B ETI 54260161 2' LED FIXTURE
SURFACE MOUNT 20
C ETI 55301101 LED EXIT SIGN --
D ETI 55502201
LED EXIT SIGN /
EMERGENCY LIGHT
COMBO WITH (2) HEADS
--
E ETI 55501101 LED EMERGENCY LIGHT
WITH (2) HEADS --
F ETI 55503101 LED EGRESS EMERGENCY
LIGHT WITH (2) HEADS --
G
SHENZHEN SNC
OPTP
ELECTRONIC CO
SNC-FWP01-40CT4A1-40 LED WALL PACK 40
H ASMART LIGHT
CO.PRO-SC11-150WCT3A1
LED AREA LIGHT ON WALL
MOUNT 42" EXTENSION
ARM
153
HB-SS ASMART LIGHT
CO.
PRO-SC11-150WCT3A1 W/
SIDE SHIELDED
(1) LED AREA LIGHTS
ON 18' POLE
(#SSS-A-18-40-A-2L-xx-xx-U
L, HUBBELL LIGHTING) & 2'
CONCRETE BASE
153
HB-SS-
BH
ASMART LIGHT
CO.
(2) PRO-SC11-150WCT3A1
W/ SIDE SHIELDED
(2) LED AREA LIGHTS
ON 18' POLE
(#SSS-A-18-40-A-2L-xx-xx-U
L, HUBBELL LIGHTING) & 2'
CONCRETE BASE
306
NOTE: REFER TO SHEET 'T01' FOR NATIONAL ACCOUNT VENDORS LIST
B-15
A A A
F
B-16
E
B-16
E
B-16
E
B-16
E
B-16
G
B-33
m
m
m
B/13
B/13
B/13
D
B/13
E
B/13
E
B/16
B/13
B-13
B-13E
B-13
A-1 NL
A-1
1" PVC SCH. 40 UNDER GRADE
CIRCUITS TO SITE LIGHTING
B-27
PYLON SIGN, 1" PVC SCH.
40 UNDER GRADE, B-25
J
J
J
MENS
104
WOMEN
105
OFFICE
101
BREAK ROOM
100
H
B-41
SERVICE CLOSET
107
NOTE:
ALL INTERIOR
LIGHTS CIRCUIT
TO PANEL B
SALES FLOOR
LIGHTS 11' AFF
D
B/9
E
B-3
8' AFF
E
B-3
8' AFF
E
B-3
8' AFF
B/13
B-13
E
$m
$m
E
B-16
E
B-16
E
B-16
B-16
E
B-16
E
B-16
E
E
B-16
B-16
E
E
B-16
E
B-16
G
B-33
H
B-33
G
B-33
H
B-33
H
B-35
B-35
H
G
B-33
G
B-33
1981 ROUTE 32.MONTVILLE, CTRZDesign Associates, Inc.
MECHANICAL, ELECTRICAL,
AND STRUCTURAL ENGINEERING
750 OLD MAIN STREET
SUITE 202ROCKY HILL, CT 06067P: (860) 436-4336F: (860) 436-4450www.rzdesignassociates.com