Loading...
HomeMy WebLinkAboutLighting Electrical Plan Revo o o o o o o LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD (((((((((((((((((((((((((((((((((((((((((((( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ((( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ((( ( ( ( ( ( ( ( ( ( ( ((( ( ( ( ( ( ( ( ( ( ( ( ( ( ((((((((((((((((((((( ((( ((((((((((((((((((((( ((((((((0000 >>>>>>>>>>>> X X X X X X >>>>>> > >>>> > >>>> X X X X X X X X 1 ES1 SCALE: ELECTRICAL SITE PLAN 1/16" = 1' - 0" H WALL PA CK, REFER TO KEY NOTE #M (TYPICAL) FLOOD WITH 42" EXPANSION ARM, REFER TO KEY NOTE #M LIGHTED PYLON SIGN WITH UNDERGROUND ELECTRICAL CONDUIT. COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS SEE NOTE#A. PROVIDE 2#8AWG, 1#10AWG "G" IN 1" CONDUIT THROUGH OUT CIRCUIT B/25 B/27 PROVIDE 2#8AWG, 1#10AWG "G" IN 1" CONDUIT THROUGH OUT CIRCUIT 18' HIGH SITE LIGHT POLE WITH (1) HEAD, 2' CONCRETE BASE AND UNDERGROUND ELECTRICAL CONDUITS. COORDINATE EXACT LOCATION WITH PHOTOMETRIC PLAN. HB-SS-BH HB-SS 18' HIGH SITE LIGHT POLE WITH (2) HEAD, 2' CONCRETE BASE AND UNDERGROUND ELECTRICAL CONDUITS. COORDINATE EXACT LOCATION WITH PHOTOMETRIC PLAN. H G H H G H G G G SITE LIGHTING GENERAL NOTES A.FINAL SIGN CONNECTION AND UNDERGROUND CONDUIT IS LANDLORD RESPONSIBILITY. PROVIDE CONDUIT FROM THE ELECTRICAL PANEL TO LOCATION OF THE PYLON SIGN BASE. BURY CONDUIT UNDER PARKING AREA. THE CONDUIT IS TO BE 1" AND HAVE ONE SET TO #8/2 WIRE WITH GROUND AND A 20-AMP SINGLE POLE BREAKER AT THE PANEL. A TEMPORARY 3' TALL STAKE SHALL BE PROVIDED TO DESIGNATE THE PYLON SIGN LOCATION UNTIL THE SIGN IS PERMANENTLY INSTALLED. REMOVE POST AFTER SIGN IS INSTALLED. B. SITE / PARKING LOT LIGHTING: PROVIDE ADEQUATE POLE AND/OR WALL LIGHTING FOR NIGHT VISION AROUND ENTRY, PARKING AND DUMPSTER PAD AREAS. C.MINIMUM OF 1.5 FOOT-CANDLES REQUIRED FOR ALL PAVED AREAS EXCLUDING 15' PERIMETER FROM EDGE OF PAVEMENT. D.REQUIRED LIGHTING: A COMBINATION OF POLE LIGHTS, FLOOD LIGHTS WITH ARM AND WALL PACKS WILL BE USED. REFER TO ELECTRICAL SITE PLAN AND SHEET E2 FOR ADDITIONAL INFORMATION. E.PLEASE NOTE THAT LIGHTING DESIGN AND LAYOUT SHOULD BE SITE SPECIFIC & MAY REQUIRE ADDITIONAL LIGHTING TO COMPLY WITH SITE DESIGN CONDITIONS. THEREFORE, MAKE PROVISIONS FOR MORE POLE LIGHTING WHEN A SPECIFIC SITE REQUIRES IT. F.UNDERGROUND ELECTRICAL SHALL BE PROVIDED TO THE SITE LIGHT POLES. G.WHERE LOCAL JURISDICTIONS DO NOT ALLOW DOLLAR GENERAL'S REQUIRED LIGHTING PLAN, AN ALTERNATE SITE LIGHTING PLAN & PHOTOMETRIC PLAN MUST BE SUBMITTED FOR APPROVAL TO THE DOLLAR GENERAL ARCHITECTURAL AND ENGINEERING DEPARTMENT. H.PHOTOMETRIC SITE ANALYSIS AVAILABLE THROUGH DOLLAR GENERAL VENDOR, LEDS LLC. I.DOLLAR GENERAL VENDOR PRICING FOR WALL PACKS OR POLE LIGHTING AVAILABLE FROM LEDS LLC. J.SEE SHEET E2 FOR MORE INFORMATION. K.VERIFY LOCAL DARK SKY REQUIREMENTS AND CONTACT VENDORS FOR APPROVED ALTERNATES IF REQUIRED. L.ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE THE LIGHTING POLE WITH WIND RATING OF AREA INSTALLED. M.CONTRACTOR TO COORDINATE MOUNTING HEIGHT OF LIGHT FIXTURE WITH CIVIL PLAN/PHOTOMETRIC PLAN.1981 ROUTE 32.MONTVILLE, CTRZDesign Associates, Inc. MECHANICAL, ELECTRICAL,AND STRUCTURAL ENGINEERING 750 OLD MAIN STREET SUITE 202ROCKY HILL, CT 06067P: (860) 436-4336F: (860) 436-4450www.rzdesignassociates.com