Loading...
HomeMy WebLinkAboutPlans3 SP A C E S 2 SPACES 3 SPACES 2 SPAC E S 2 SPACES NO PARKI N G NEW DIESEL & KEROSENE DISPENSER ON CONC. ISLAND FORM NEW AREA LIGHT U-BOLLARD (TYP.) REPLACE EX. FENCE PR. VENT RISERS AND OVERFILL ALARM PANEL (SEE DETAIL 2/S-3) PR. HANDICAP PARKING SIGN (VAN ACCESSIBLE) ENTIRE EX. SEPTIC SYSTEM TO BE ABANDONED PER CT PUBLIC HEALTH CODE EX. VACCUM TO REMAIN EX. PROPANE TANK CONTAINMENT TO REMAIN PR. STOCKADE FENCE PR. FENCE PR. 12'x23' FENCED TRASH ENCLOSURE ON 22'x23' CONC. PAD PR. POSITIVE LIMITING BARRIER (TYP.) NO LEFT TURN SIGN NO LEFT TURN SIGN REMOVE EX. CURB & PARKING BLOCKS PR. BIT. CONC. CURB (TYP.) REMOVE EX. STUMPS REPLACE EX. BIT. CONC. CURB (TYP.) ENTIRE SITE TO BE REPAVED EX. BIT. CONC. CURB TO REMAIN (TYP.) PR. SAWCUT (TYP.) INSTALL 3' RADIUS ORANGE CONSTRUCTION FENCE AS EXISTING WELL PROTECTION POSSIBLE LOCATION FOR NEW WELL (IF NEEDED) SITE PLAN C-101 LEGEND DBE | DAS | MBE | GNMSDC CERTIFIED CIVIL | GEOTECHNICAL SURVEY | ENVIRONMENTAL FREEMAN COMPANIES, LLC 36 JOHN STREET HARTFORD, CT 06106 WWW.FREEMANCOS.COM TEL:(860)251-9550 TOLL FREE:(800)604-5141 FAX:(860)986-7161 ELEVATE YOUR EXPECTATIONS LEEMILT'S PETROLEUM612 NORWICH-SALEM TURNPIKE (RT 163/82), OAKDALE, CT 06370x 427.37 x 429.30 429.05 x x 429.05 x 429.10 x 429.10 x 427.77 x 427.37 x 427.57 x 427.67 x 427.14 x 427.10 PR. LEVEL SPREADER (1.5' x 10' x 4.1') TOP STONE = 426.1 BOTTOM STONE = 422.0 INV = 422.7 (IN-12" PVC-N)) (ASTM #4 STONE: 3/4" to 1-1/2") PR. HYDRODYNAMIC SEPARATOR CONTECH STORMCEPTOR STC-900 (OR EQUIVALENT) TOP OF UNIT = 426.0 INV = 422.9 (IN-12" PVC-N) INV = 422.8 (OUT-12" PVC-S) BOTTOM OF UNIT = 418.3 EX. 18" RCP TO REMAIN. VIDEO FOR BLOCKAGE. CLEAR BLOCKAGE IF NECESSARY. EX. CATCH BASIN TO REMAIN REMOVE EX. OUTLET PIPE EX. ISLAND CURBING TO REMAIN (TYP.) PR. 6" PVC ROOF LEADER (TYP.) ~165' - 6" PVC @ 1.8%± ~8' - 12" PERF PVC @ 0% INV = 426.0± ~4' - 12" PERF PVC @ 2%± ~3' - 12" PERF PVC @ 3%± TIE IN EXISTING 18" RCP WITH PR. CATCH BASIN x 427.10 PR. CATCH BASIN - DEEP SUMP W/ HOODED OUTLET TYPE II-CL-DOUBLE GRATE TF = 426.9 INV = 423.0 (IN-EX. 18" RCP-NW) INV = 423.0 (IN-6" PVC-W) INV = 423.0 (OUT-12" PVC-S) SUMP = 419.0 GRADING & DRAINAGE PLAN C-102 LEGEND DBE | DAS | MBE | GNMSDC CERTIFIED CIVIL | GEOTECHNICAL SURVEY | ENVIRONMENTAL FREEMAN COMPANIES, LLC 36 JOHN STREET HARTFORD, CT 06106 WWW.FREEMANCOS.COM TEL:(860)251-9550 TOLL FREE:(800)604-5141 FAX:(860)986-7161 ELEVATE YOUR EXPECTATIONS LEEMILT'S PETROLEUM612 NORWICH-SALEM TURNPIKE (RT 163/82), OAKDALE, CT 06370x 427.37 TYP. JOINTWALL C BELOW PIPE INVERT TYP. JOINT ABOVE PIPE INVERT WALL A PLAN VIEW WALL A WALL BWALL DWALL BGENERAL NOTES 1.CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2.FOR SITE SPECIFIC DRAWINGS WITH DETAILED STRUCTURE DIMENSIONS AND WEIGHT, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.ContechES.com 3.STORMCEPTOR WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. CONTRACTOR TO CONFIRM STRUCTURE MEETS REQUIREMENTS OF PROJECT. 4.STORMCEPTOR STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 2' [610], AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. 5.STORMCEPTOR STRUCTURE SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C478 AND AASHTO LOAD FACTOR DESIGN METHOD. 6.ALTERNATE UNITS ARE SHOWN IN MILLIMETERS [mm]. INSTALLATION NOTES A.ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. B.CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMCEPTOR MANHOLE STRUCTURE. C.CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. D.CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET AND OUTLET PIPE(S). MATCH PIPE INVERTS WITH ELEVATIONS SHOWN. ALL PIPE CENTERLINES TO MATCH PIPE OPENING CENTERLINES. E.CONTRACTOR TO TAKE APPROPRIATE MEASURES TO ASSURE UNIT IS WATER TIGHT, HOLDING WATER TO FLOWLINE INVERT MINIMUM. IT IS SUGGESTED THAT ALL JOINTS BELOW PIPE INVERTS ARE GROUTED.1'-7" [483]WEIR1'-6" [457](4'-6" [1372] MIN.)VARIES6'-0" [1829] I.D. MANHOLE STRUCTURE A FLOW 6" [152]Ø ORIFICE PLATE SAFETY GRATE OVER OUTLET RISER TOP SLAB ACCESS TO BE ORIENTED OVER OIL INSPECTION PIPE AND OUTLET RISER (SEE FRAME AND COVER DETAIL) PLAN VIEW TOP SLAB NOT SHOWN www.ContechES.com CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RINGS/RISERS (NOT PROVIDED BY CONTECH) PERMANENT POOL ELEVATION STORMCEPTOR INSERT 6" [152]Ø OIL INSPECTION PIPE (TOP 1" [25] MIN. FROM INSIDE OF TOP SLAB) SAFETY GRATE INLET PIPE OUTLET PIPE 12" [305]Ø DROP TEE 24" [610]Ø OUTLET RISER SOLIDS STORAGE SUMP SECTION A-A FOR PATENT INFORMATION, GO TO www.ContechES.com/IP ® FRAME AND COVER (MAY VARY) NOT TO SCALE FLOW A +/-90° PR. 12" COMPOST FILTER SOCK OR APPROVED EQUIVALENT (TYP.) EX. TREE CLEARING LIMITS INSTALL SILT SACK (TYP.) TEMPORARY STOCKPILE AREA. COMPOST FILTER SOCK OPENING SHALL BE ON UPHILL SIDE . PR. TREE CLEARING LIMITS INSTALL DRAINAGE HOOD ON OUTLET PIPE EROSION & SEDIMENTATION CONTROL PLAN C-103 LEGEND DBE | DAS | MBE | GNMSDC CERTIFIED CIVIL | GEOTECHNICAL SURVEY | ENVIRONMENTAL FREEMAN COMPANIES, LLC 36 JOHN STREET HARTFORD, CT 06106 WWW.FREEMANCOS.COM TEL:(860)251-9550 TOLL FREE:(800)604-5141 FAX:(860)986-7161 ELEVATE YOUR EXPECTATIONS LEEMILT'S PETROLEUM612 NORWICH-SALEM TURNPIKE (RT 163/82), OAKDALE, CT 063701.5" X 1.5" WOODEN STAKES PLACED 10' O.C. SECTION NTS PLAN NTS NOTES: 1.ALL MATERIAL TO MEET SPECIFICATIONS. 2.COMPOST SOCKS FILL TO MEET APPLICATION REQUIREMENTS. 3.FILTER MEDIA TO BE DISPERSED ON SITE, AS DETERMINED BY ENGINEER. 12" MIN COMPOST SOCK (12" TYPICAL) AREA TO BE PROTECTEDWORK AREA WORK AREA AREA TO BE PROTECTED 1.5" X 1.5" WOODEN STAKES PLACED 10' O.C. COMPOST SOCK (8" or 12" TYPICAL) WATER FLOW PR. 1,000 GAL. SEPTIC TANK TOP OF FRAME = 429.00 TOP OF TANK = 426.70 INV = 425.90 (IN-4" PVC-E) INV = 425.65 (OUT-4" PVC-W) BOT OF TANK = 421.32 INSTALL RISERS TO GRADE ~18' - 4" PVC SCH 40 ASTM 3034 S=2% VERIFY IN FIELD PRIOR TO CONSTR. INV = 426.30± PR. DIST. BOX INV = 424.50 (IN-4" PVC-E) INV = 424.40 (OUT-4" PVC-S) INV = 424.40 (OUT-4" PVC-S) ~56' - 4" PVC SCH 40 ASTM 3034 S=2% SEPTIC PLAN C-104 LEGEND DBE | DAS | MBE | GNMSDC CERTIFIED CIVIL | GEOTECHNICAL SURVEY | ENVIRONMENTAL FREEMAN COMPANIES, LLC 36 JOHN STREET HARTFORD, CT 06106 WWW.FREEMANCOS.COM TEL:(860)251-9550 TOLL FREE:(800)604-5141 FAX:(860)986-7161 ELEVATE YOUR EXPECTATIONS LEEMILT'S PETROLEUM612 NORWICH-SALEM TURNPIKE (RT 163/82), OAKDALE, CT 06370