Loading...
HomeMy WebLinkAboutSite PlanF °z A-03023'07" ( \ R-844.64' L-49.90" CBRG-NI1°35'47"E CHD-49.90' \30� IP REC. 11 3 �. IPIN \ SET .......... .......... CHRISTOPHER J. KOBYLUCK& .�' t °p \ / � ...•... ,.-.. •._ -- - - �- •r r' Y -V � ; �'� 1,�_l SUSAN M. KOBYLUCK / VOL. 407 PG. 652 SIN ` - 9784 / �`.114.11' !_- 1 ......... 30'L ]PIN- S 15' -SET ERCP / � �Op 98.5Gk4j)ETO�j�� _,� \ � S E �^ '.:•:.:•:.:.:.:.:. O _ 1 ► 37, TF -300.53 -- / \\ j' / j i%/� �/ _ \ Il - - _ i - ` _ -3 00 INV.IN-296.5 - \ / A-02002'06" INV.OUT-296.5 // \\ MON ^,°� f, ../%. ` 1 �tj� '( \ \ #� r R-844.64' // REQ. i so , `GES , _ _ tl ` _ BFN f i%V1 i�IQK IN L-30.00' 11 t \ r i 29g3p /f - i1 _1' ry - \1� - _ - - - J S T 1'or OF IRON► 11IN CBRG-N14°18'23" �; \ IS°RCP _ - _ - 219-60 \ AB / / S j �: EL EV, `W 1 I 66'-4"PVC SCHED.40 J 1,250 GALLON - - .-- - - -__ ; r. . CHD-30.00 g NcyMRKK / \ / (REMOI��PROPOSED r-.��`---,! �92'SSr 1 --S=I/4"/FT. %� SEPTIC TANK -� -- - -- -_ :.:.:.: 0 0 % WELL j / - - -` -INV: 29!• 17 IN 298 ...... . T \\ / . 0 N u f Y1 G + r /� \\i j f - ` , 5, _ INV. 290 9Z dU I` M i PROPOS - - BOTTOM -OF- - _ I Et EY 29q•39 rik �\\ � � � / V ; 4Ei� � DECg j � - l � 4'x8'x12" HIGH \� j ,� OOp 1 CONCRETE A-02°02'06" .� s M / / ; j % NoUs 9 s- Mnv. _ ..:..,:__,= ._:-: � �� t � ,��- --�. �- - -�� _ GALLERIES- - R-844.64' 'l" /- % BStV1,1. 00 l \ _ l� ELI'V 289.E-2 , ` _- -" - ` .296 L-30.00' / ` \ 29u - % So S=0.041 CBRG-N 16°20'29"E CHD-30.00' // / I % f� l l j j - - - _. _ - _ _ - c -- - -294 N/F OVERFLOW D -BOX 00 SANDRA J. EICHELBERG t INV.289.42IN N VOL. 407 PG. 656 D -sox \ `� INV. 210.42OUT ` // tG1oN / I III f INV. 29 o DIIN - _ _ _ - - �- - - - - - - -- 292 1 O 'REC. / / / j - -_ _ - - -/ - - L - j- INV. 289.420UT.. Pte` 313:..:.....:.:. /-�/ 7 12049/ ° 0+ ! - TH#3A 9,T•YP` 1 EL C. / � � "'- ``- 4"PVC ........ / ,� $ FEASIBLE x ?89.0 rN , A �3G"I pp- _ _ _ _ UNDERGROUND / % CLEARING f� I v UTILITY SERVICE LIMIT \� 3 .4, r /CONNECTION / / , FEASIBLE 1 °0 �.�� INV. 2t;R.67INf `288 32-4 PVC FUT'j^> ✓fl 'L = - _ - _ 00% RESER INV. <00`.T r1 ' FO_OTING iRAI14 - j-,. ,- - - -� ' �►� i0 _ - - cv - - - �'' ' e - - iEA _ _ M 20'x40' IN GROUND _ ni- 28 - // S�.07+ 1 - o ` r OR 30 DLA. ABOVE INV. 287.51 WITH GROUND TH#3D L �� TH#3C �^ .......... � =286 / IN PERFORATED END CAP 292 - - _ •� W STALL & MAINTAIN -� -- / �. Cv / CONTINUOUS LINE OF SILT FENCE (SEE DETAIL) .. •..:. '''...... ..... - .......... .......... . BOTTOM OF -� 284 4'x8'x12" HIGH -;� CONCRETE so' GALLERIES �\� - HOAS ELEV 288.00 SHOWN PER SUBDIVISION MAP 'REC./ ti NOTES: B'FERAREA / 282 :.:..:::.:.:::::. CAST - • / CONCRETE COVERS 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN'i 1E FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT. 3. BASE FOR LEVELS: PER REFERENCE MAP. 4. THE PROPERTY IS SHOWN ON ASSESSORS MAP 39 - LOT 98-03. 5. THE PROPERTY IS LOCATED IN ZONING DISTRICT R-40. 6. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM orvr r LOCATED ON ABUTTING PROPERTIES. PERC # LOCATION DEPTH PRES(A& PERCOLATION RXI r 7. TOTAL AREA OF PROPERTY - 64,523 S.F.f - (1.48 ACRES t). 3 see sketch 32" 60 tr mites 6.33 minrnch REFERENCE MAP: PROPERTY SURVEY PREPARED FOR WILLIAM PIENIADZ, #49 PIRES DRIVE, MONTVILLE, CONNECTICUT, DATE: 2/24/05, SCALE: 1"=201, PREPARED BY ADVANCED SURVEYS, LLC. LEGEND: KNOCKOUT INLET AND OUTLET OPENINGS F.F. FIRST FLOOR EL. ELEVATION + + TYP. N IPIN IRON PIN MON U B'FERAREA / 282 :.:..:::.:.:::::. CAST - • / CONCRETE COVERS 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN'i 1E FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT. 3. BASE FOR LEVELS: PER REFERENCE MAP. 4. THE PROPERTY IS SHOWN ON ASSESSORS MAP 39 - LOT 98-03. 5. THE PROPERTY IS LOCATED IN ZONING DISTRICT R-40. 6. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM orvr r LOCATED ON ABUTTING PROPERTIES. PERC # LOCATION DEPTH PRES(A& PERCOLATION RXI r 7. TOTAL AREA OF PROPERTY - 64,523 S.F.f - (1.48 ACRES t). 3 see sketch 32" 60 tr mites 6.33 minrnch REFERENCE MAP: PROPERTY SURVEY PREPARED FOR WILLIAM PIENIADZ, #49 PIRES DRIVE, MONTVILLE, CONNECTICUT, DATE: 2/24/05, SCALE: 1"=201, PREPARED BY ADVANCED SURVEYS, LLC. LEGEND: Test Hole # B F.F. FIRST FLOOR EL. ELEVATION S.F. SQUARE FEET TYP. TYPICAL IPIN IRON PIN MON MONUMENT x305.6 PROPOSED SPOT ELEVATION - - 302 - - EXISTING CONTOURS r 3"v2� PROPOSED CONTOURS TEST HOLE OBSERVATION PITS: DATE: 4-19-05 WATER TABLE: Creno max Tat Hole # A Test Hole # B Ted H & # C Test Hole # 0.5" Topsoil 0-5- Topsoil 0-5- 1'a"Mi 53r 5-38" brown sandy loam 546" Brown sandy loam 5-W'39-0 aandy koro E'" 38-55" Grey sandy till 46-56" Grey sandy till 46.60" gay sandy tin a-- Tat Hole # Location Depth Le lge Water Mottling A See sketch '5" 5)" - - B See sketch 56" 53r 46" 46" C See sketch 60" E'" 48" - a-- 101 CI• ill, FILTER _ i 3' VENT. -.- FABRIC 3/10/05 LI UID LEVEL ANGLE Ir UP SLOPE POST FOR STABILITY AND �• SELF CLrANING COMPACTED UE RA( X111. SILT FENCE NOT TO SCALE 4" PVC ELBOW (CUT FORV OVERFLOW) 2)(2 5/816 GA. WIRE MESH , k 1 ln" 12" BROKEN STONE OR I" SCREENED GRAVEL TYPICAL BOTH SIDES. LIFTING HANDLES a v • o0 1 4'x8"x12" HIGH CONCRETE map is substantially correct as noted hereon. 2, LEACHING GALLERY• Robert :i. SyZ7,604, P. i?. Certificatiosf not vE'id without live signature and embossed (impression) type seal. STANDARD D -BOX W/ELBOW NOT TO SCALE 48" 4" DIA. HOLE FILTER FABRIC INLE _ i 3' VENT. -.- 07 3/10/05 LI UID LEVEL P CONTINUOUS HOT ASPHALT SEAL " SCHED. #40 TM PT RAPM Vt REVISIONS 4-�7- 05 CROSS SECTION 1250/1500 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE FINISHED GRADE LOAM A SEED, GRADE TO PREVENT PONDING ff�1 ' �••••6.4r FLOW UNE KNOCKOUTS.INSTALLATION t TO MOTTLING•GROUNDWATER 48* MIN. • LEDGEIROCK END VIEW 12" HIGH GALLERY UNIT Car ro scwrs NOTES: 1. THIS SEPTIC SYSTEM INSTALLATION INCLUDING ALL MATERIALS (PIPING, SEPTIC TANK, STONE, FILL, ETC.) USED FOR THIS SEPTIC SYSTEM SHALL CONFORM TO THE CURRENT EDITION/REVISION OF THE "TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS" REVISED JANUARY 1, 2004 OF THE CONNECTICUT PUBLIC HEALTH CODE BY THE STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH. 2. THE PROPOSED HOUSE SEWER FROM THE BUILDING TO THE SEPTIC TANK SHALL BE SCHEDULE 40 PVC ASTM D 1785/ASTM D 2665 OR APPROVED EQUAL AND INDICATED IN TABLE NO. 2 OF "TECHNICAL STANDARDS FOR SUBSURFACE SEWAGE DISPOSAL SYSTEMS". ALL OTHER SEWER PIPE FOR THIS SEPTIC SYSTEM SHALL BE 4" PVC ASTM D3034, SDR 35 WITH RUBBER COMPRESSION GASKET OR BELL AND SPIGOT OR APPROVED EQUAL. 3. THERE ARE NO WELLS (POTABLE, GEOTHERMAL, OR IRRIGATION) WITHIN 75' OF THE PROPOSEI) SEPTIC SYSTEM. 4. THERE SHALL BE NO STUMPS OR BOULDERS BURIED WITHIN 50' DOWN GRADIENT OF THE SEPTIC SYSTEM. SHOULD ANY SIGNIFICANT VARIATIONS FROM THE TEST HOLE DATA BE ENCOUNTERED DURING EXCAVATIONS (LEDGE, GROUNDWATER, MOTTLING, SOIL TYPE, ETC.), THE DESIGN ENGINEER SHALL BE NOTIFIED PRIOR TO INSTALLATION OF THE SEPTIC SYSTEM. 5. ALL EXISTING UTILITIES ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS AND ELEVATIONS PRIOR TO ANY CONSTRUCTION. CONTRACTOR SHALL CONTACT "CALL -BEFORE -YOU -DIG" AT 1-800-922-4455 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. 6. THE PROPOSED FILL FOR THIS SEPTIC SYSTEM SHALL MEET THE FOLLOWING SPECIFICATIONS: A. 100° o OF FILL SHALL PASS THROUGH A 3" SIEVE. B. MAXIMUM % OF GRAVEL (BETWEEN #4 & 3" SIEVE) = 45 %. C. GRADATION OF FILL WITHOUT THE GRAVEL SHALL MEET THE FOLLOWING CRITERIA: SIEVE SIZE % PASSING (WET) % PASSING (DRY) #4 100% 100% # 10 70-100% 70-100% #40 10-50% 10-75% #100 0-20% 0-5% #200 0-5% 0-2.5% D. • PERCENT PASSING THE #40 WET SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5 %. E. PERCOLATION RATE AFTER PLACEMENT AND COMPACTION SHALL BE FASTER THAN OR EQUAL TO 20.0 MINUTESANCH. A WET OR DRY SIEVE ANALYSIS MAY BE REQUIRED PRIOR TO FILL PLACEMENT TO VERIFY THAT IT MEETS THESE SPECIFICATIONS. THE FILL SHALL BE APPROVED BY THE UNCAS HEALTH DISTRICT OR DESIGN ENGINEER PRIOR TO ITS PLACEMENT ON SITE. 7. APPROVED AGGREGATE SHALL BE STONE AGGREGATE OR OTHER PRODUCTS APPROVED BY THE COMMISSIONER OF PUBLIC HEALTH. STONE AGGREGATE SHALL BE BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING THE CONNECTICUT DEPARTMENT OF TRANSPORTATION FORM 816 (OR LATEST REVISION THERETO) SPECIFICATION M.01.01 FOR NO.4 STONE, FREE OF SILT, DIRT, OR DEBRIS, SHALL SHOW A LOSS OF ABRASION OF NOT MORE THAN 50% USING AASHTO METHOD T-96 AND CONFORM TO THE FOLLOWING: SIEVE SIZE % PASSING 2 INCH 100% 1.5 INCH 90-100% 1 INCH 20-55% 3/4 INCH 0-10% 3/8 INCH 0-5% 8. NO DEVIATION FROM THE APPROVED DESIGN PLAN SHALL BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE UNCAS HEALTH DISTRICT AND THE DESIGN ENGINEER. 9. THE SEPTIC TANK SHALL BE PRECAST CONCRETE UNLESS OTHERWISE AUTHORIZED BY THE DESIGN ENGINEER. 10. SITE PREPARATION PROCEDURE FOR THE INSTALLATION OF THE PROPOSED SEPTIC SYSTEM: A. STRIP ALL TOPSOIL, VEGETATION AND ORGANIC MATERIAL IN THE AREA OF AND 5' SURROUNDING THE PRIMARY LEACHING GALLERIES. B. USING A HEAVY RAKE OR EQUAL, THOROUGHLY SCARIFY AND ROUGHEN UP THE EXPOSED SUBSOIL. PREVENT ANY VEHICULAR TRAFFIC, BACKHOE, TRUCKS, ETC. FROM SMOOTHING/COMPACTING THIS EXPOSED SUBSOIL. C. PLACE AND COMPACT SELECT FILL MATERIAL MEETING SPECIFICATIONS INDICATED ABOVE (NOTE #6) IN LIFTS OF NOT GREATER THAN 12" IN THE AREA OF THE PROPOSED LEACHING GALLERIES UP TO AT LEAST THE ELEVATION OF THE TOP OF THE LEACHING GALLERIES. D. PERFORM AT LEAST 1 PERCOLATION TEST ON PLACED FILL. FILL MUST HAVE A PERCOLATION RATE EQUAL TO OR FASTER THAN THAT AS INDICATED IN NOTE #6.D. IF PERCOLATION RATE IS SLOWER THAN THAT RATE, ALL FILL SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE FILL MEETING PROPER SPECIFICATIONS. E. INSTALL SEPTIC SYSTEM PER PLAN USING APPROVED AGGREGATE AS INDICATED IN NOTE #7. F. COVI'R SYSTEM WITH A MINRAIAf OF 6" OF LOAM IN LAWN AREAS, GRADE m0 PREVENT rG:; Li;::; AiV'71' C,_^, : C ^':,iL1Zli.P-E kLNL 1S;u;L' GitADE i 0'.1110M ANY FART OF THE FROPOSED LEACHING GALLERIES SHALL BE AT LEAST THE SAME ELEVATION AS THE TOP OF THE RESPECTIVE LEACHING GALLERY. G. CLEANOUT MANHOLES AT THE INLET BAFFLE AND AT THE OUTLET FILTER OF THE SEPTIC TANK OR ASSOCIATED RISERS AT THESE LOCATIONS IF REQUIRED SHALL BE LOCATED AT A DEPTH NOT GREATER THAN 12" BELOW FINAL GRADE. 11. FOR EXACT HOUSE DIMENSIONS, SEE BUILDING PLANS. TEST HOLE & PERC DATA WITNESSED BY RAY ANDREWS R.S. UNCAS HEALTH DISTRICT -1/4/99 & 10/15/99 rH43A - 0"-14" TOPSOIL TH#3D - 0"-10" TOPSOIL -14"-48" SUBSOIL -10"-50" SUBSOIL DEPTH OF HOLE 48" DEPTH OF HOLE 50" NO WATER, NO MOTT., LEDGE@48" NO WATER, NO MOTT., LEDGE@50" TH43B - 0"-10" TOPSOIL TH#3E - 0"-10" TOPSOIL. -10"-36" SUBSOIL -10"-40" SUBSOIL - 36"-60" GREY SANDY TILL - 40"-88" LIGHT GREY MED. COMPACT SANDY SILT DEPTH OF HOLE 60" DEPTH OF HOLE 88" WATER@58", MOTT.@36", LEDGE@60" NO WATER, MOTT.@40", NO LEDGE TH#3C - 0"-16" TOPSOIL -16"-28" SUBSOIL - 28"-58" GREY SANDY TILL DEPTH OF HOLE 60" WATER@50", MOTT.@36", LEDGE@60" PERCOLATION TESTS WERE PERFORMED BY RAY ANDREWS OF THE UNCAS HEALTH DISTRICT ON 4/16/99. -OUTLET PERCOLATION TEST - PRIMARY AREA - PERCOLATION RATE =13.3 MINUTES/INCH -OUTLET PERCOLATION TEST - RESERVE AREA - PERCOLATION RATE =10 MINUTES/INCH FILTER U DEVICE SANITARY DESIGN CRITERIA PROPOSED 4 BEDROOM HOUSE DESIGN PERCOLATION RATE = 5.1-10.0 MINUTES/INCH LEACHING AREA REQUIRED = 660 SF EFFECTIVE DESIGN: 1,250 -GALLON SEPTIC TANK AND 2 ROWS OF 56' TOTALING 112' OF 4' WIDE, 8' LONG,12" HIGH CONCRETE LEACHING GALLERIES WITH 12" OF 1" STONE SURROUNDING ALL SIDES BY SERIAL DISTRIBUTION. LEACHING AREA PROVIDED: 2 x 58'x 5.9 SF/LF = 684.4 SF EFFECTIVE 100% RESERVE AREA PROVIDED (12" HIGH CONCRETE GALLERIES) MINIMUM LEACHING SYSTEM SPREAD CALCULATION HYDP.AULIC GRADIENT = 8.3 % DEPTH TO RESTRICTIVE LAYER = 36" HYDRAULIC FACTOR = 24 FLOW FACTOR FOR 4 BEDROOMS = 2.0 PERCOLATION FACTOR FOR 5.1-10.0 MINLTTESANCH =1.2 MLSS REQUIRED = 57.6' MLSS PROVIDED = 58' PROM.37 NO. 05-009 DRAW11 BY: R.A.D. DATE: 3/10/05 SCALE: 1"=20' SHEET l OF 1 REVISIONS 4-�7- 05 5-1(,- 05- 20 10 0 :0 Qg ' C'RAPHiC SCALE IN FEET SEPTIC SYSTEM DESIGN PLAN PREPARED FOR WILLIAM PIENIADZ #49 PIKES DRIVE MONTVII,LE, CONNECTICUT Robert J. Schuch, P.E. CONSULTING ENGINEER 57 Sarah Dive Uncasville, CT 06382 860-848-1539 Fax 860-848-1539 8604604369 dschuch@snet.net