Loading...
HomeMy WebLinkAboutSite PlanS76°29'1 3 " E N83°15'03"W 70.00' ±12.1 '106106105105104104103103102102 10 2 102101101 1 0 1 101100100 100100999999999898989897979797969696969595959594949393929291919090 89 89 8888 8787 ±12.3'30.77'30.9'N69° 2 7 ' 0 3 " W S12°44'57"W31.00'75.46 ' G 25' 75'N26°23'52"EW 25' 75' 9594 93 TANK PRIMARY 25 L.F. STOCK PILE 137.13'9.3'3.0' 67.7' 45.5'- PREPARED FOR -MONTVILLE CONNECTICUTELISA & STEVEN PIERCE157 DOYLE ROAD UNIT B1 inch = ft. ( IN FEET ) GRAPHIC SCALE ROBERT W. HELLSTROM, L.S. #13626TO MY KNOWLEDGE AND BELIEF, THIS MAP ISSUBSTANTIALLY CORRECT AS NOTED HEREON.1 OF 2SITE DEVELOPMENT PLANMAY 5, 2021AGS1" = 10'21-025_SitepPlan2021-02510 0'10'20'30'ALL RIGHTS RESERVEDANY REPRODUCTION, POSSESSION OR USE OF THIS DRAWING OR ANY PART THEREOF WITHOUT THEWRITTEN PERMISSION OF THE SURVEYOR INDICATED BELOW IS PROHIBITED. VIOLATORS WILL BEPROSECUTED TO THE FULL EXTENT OF THE LAW.www.RHLSCT.comMAP STANDARD NOTES 1.THIS SURVEY (OR MAP) HAS BEEN PREPARED PURSUANT TO THE REGULATIONS OF CONNECTICUT STATE AGENCIES SECTIONS 20-300b-1 THRU 20-300b-20 AND THE "STANDARDS AND SUGGESTED METHODS AND PROCEDURES FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON AUGUST 29, 2019. TYPE OF SURVEY: IMPROVEMENT LOCATION SURVEY BOUNDARY DETERMINATION: RESURVEY HORIZONTAL ACCURACY CLASS: "A-2" LAND ZONE: R-120 THE INTENDED PURPOSE OF THIS MAP /SURVEY IS TO DEPICT THE PROPOSED HOUSE AND SEPTIC. LOCATION. DRILL HOLE SET ANGLE POINT IRON PIN SET 5/8" REBAR 98 EXISTING CONTOUR CHD MONUMENT FOUND IRON PIN OR PIPE FOUND PROPERTY LINE LEGEND *SEE DETAIL 'A' DETAIL 'A' NOT TO SCALE APPROX. EDGE OF WATER, 2-8-2021 DOCKSHED SHED PROPOS E D HOUSE(3 BEDR O O M ) FIN.FL.= 9 8 . 0 T.F.W.= 9 7 . 0 BASE.FL. = 8 9 . 5 S12°44'57"W31.00'*SURVEY CLOSURE LINE* ACTUAL PROPERTY LINE FOLLOWS ALONG THE EDGE OF GARDNER LAKE . N71°09'3 6 " E 0.67'N83°15'03"W 70.00' “PLOT PLAN, PORTION OF LAND OF ANNE C. ALQUIST, MONTVILLE, CONNECTICUT, DATED MAY 11, 1970, CORRECTED MAY, 1970, BY HUB CORPORATION, COLCHESTER, CONNECTICUT, EDWARD J. BAZZELL, LAND SURVEYOR.” MAP REFERENCE TP 1 PROPERTY OF ELISA & STEVEN PIERCE AREA= ±4,925 SQ.FT, ±0.1 ACRES N/F LEONARD T. & KATHLEEN A. JOHNSON N/F PEQUOT LEDGE CAMPGROUND, LLC N/F ELISA B. & STEVEN C. PIERCE BM 28" OAK ELEV.=96.75 (ASSUMED) WOOD FENCE PER MAP REFERENCE VOL.638, PAGE 323 OF THE MONTVILLE TOWN LAND RECORDS VOL. 509, PAGE 30 OF THE MONTVILLE TOWN LAND RECORDS VOL. 336, PAGE 738 OF THE MONTVILLE TOWN LAND RECORDS DEED REFERENCE 6.74' IRON PIPE FOUND RETAINING WALLS (TYPICAL) SURVEYOR CONTROL POINT SEPTIC DRY WELL EX. WELL *EXISTING WELL TO BE ABANDONED PER HEALTH DEPARTMENT STANDARDS TP 275' THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM ON THIS LOT. CONTRACTOR TO PRESERVE & PROTECT ALL EXISTING UTILITIES. PRIOR TO THE START OF CONSTRUCTION CONTACT 'CALL BEFORE YOU DIG' 1-800-922-4455 THIS PROPERTY IS NOT LOCATED WITHIN A FLOOD ZONE. BENCHMARK TO BE SET IN THE FIELD AT TIME OF CONSTRUCTION. 1. ALL EROSION & SEDIMENT CONTROL MEASURES TO BE CONSTRUCTED AS DETAILED AND SPECIFIED IN THE CONNECTICUT GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL JANUARY 2002 AS AMENDED. 1.ALL EROSION & SEDIMENT CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY CONSTRUCTION, PROPERLY MAINTAINED DURING CONSTRUCTION AND REMAIN IN PLACE UNTIL ALL DISTURBED AREAS HAVE BEEN PROPERLY STABILIZED. AFTER INSTALLATION OF THE INITIALLY PRESCRIBED MEASURES, ADDITIONAL MEASURES MAY BE REQUIRED TO ADDRESS FIELD CONDITIONS AS ORDERED BY THE TOWN OF MONTVILLE OR ITS DESIGNATED AGENT(S). 2.THE SMALLEST PRACTICAL AREA OF LAND SHOULD BE EXPOSED. THE EXPOSURE SHOULD BE THE SHORTEST PERIOD OF TIME. WHEN NECESSARY TEMPORARY VEGETATION AND OR MULCHING SHOULD BE USED TO PROTECT EXPOSED AREAS. FINAL VEGETATION SHOULD BE INSTALLED AS SOON AS POSSIBLE. WHEREVER FEASIBLE NATURAL VEGETATION SHOULD BE RETAINED AND PROTECTED. 3. THE STOCKPILING OF BUILDING MATERIALS SHALL BE WITHIN THE AREA OF DISTURBANCE. 4.SEEDBED PREPARATION: FINE GRADE AND RAKE SOIL TO REMOVE ANY STONES LARGER THAN 2 INCHES. INSTALL ANY NEEDED EROSION CONTROL DEVICES SUCH AS SURFACE WATER DIVERSIONS. APPLY LIMESTONE AT A RATE OF TWO TONS PER ACRE OR 90 POUNDS PER 1000 SQUARE FEET. FERTILIZE WITH 10-10-10 AT A RATE OF 11 POUNDS PER 100 SQUARE FEET. WORK LIME AND FERTILIZER INTO THE SOIL TO A DEPTH OF FOUR INCHES. 5.SEED APPLICATION: APPLY SHADE TOLERANT GRASS MIXTURE BY HAND, CYCLONE SEEDER OR HYDROSEEDER. SEEDING SHALL BE DONE BETWEEN APRIL 1 AND JUNE 1 OR BETWEEN AUGUST 15 AND SEPTEMBER 1. IF SEEDING CANNOT BE DONE DURING THESE TIMES, REPEAT MULCHING PROCEDURE UNTIL SEED CAN BE DONE. 6.ESTABLISH PERMANENT VEGETATION USING A SEED MIXTURE OF: KENTUCKY BLUEGRASS 20 LBS/ACRE CREEPING RED FESCUE 20 LBS/ACRE PERENNIAL RYE GRASS 5 LBS/ACRE TOTAL 45 LBS/ACRE THE RECOMMENDED DATES FOR SEEDING ARE APRIL 1 THROUGH JUNE 1 AND AUGUST 15 THROUGH SEPTEMBER 1. 7.MULCHING: IMMEDIATELY FOLLOWING SEEDING, MULCH THE SEEDED SURFACE WITH STRAW OR HAY AT A RATE OF 1.5 TO 2 TONS PER ACRE. MULCH SHALL BE SPREAD BY HAND OR WITH A MULCH BLOWER. PUNCH MULCH INTO SOIL SURFACE APPROXIMATELY TWO TO THREE INCHES. 4 1 2 SEPTIC SYSTEM INVERTS INVERT @ HOUSE - 94.7 MIN. INVERT IN @ SEPTIC TANK - 94.10 INVERT OUT @ SEPTIC TANK - 93.85 D-BOX / FLOW LINE @ UNITS - 93.50 BOTTOM OF UNITS - 91.00 EXISTING GRADE - 96.5 - 98.5 FINISHED GRADE OVER UNITS - 96.5 - 98.5 3 LIMT OF 50' URARETAINING WALLS (TYPICAL) STONE STEP (TYP.) PROPOSED WELL PROPOSED GEOTHERMAL WELL ALL DRILLING SEDIMENTS TO BE DISPOSED OF OFF SITE LOAM, SEED & MULCH ALL DISTURBED AREAS INSTALL & MAINTAIN SILT FENCE (TYP.) WELL DRILLING DISCHARGE/SETTLING AREA SURROUND WITH SILT FENCE ALL DRILLING SEDIMENTS TO BE DISPOSED OF OFF SITE EX. CO N C . P A D EX. CONC. PAD REYNOLDS ENGINEERING SERVICES, LLC 63 NORWICH AVE. COLCHESTER, CT 06415 (860) 465-7419 INSTALL GEOMATRIX GST 6230 LEACHING UNITS - 25 L.F. (SEE DETAIL) 1,000 GAL PRECAST SEPTIC TANK WITH EFFLUENT FILTER AT OUTLET (TUF-TITE EF-4 OR APPROVED EQUAL) (SEE DETAIL) INSTALL RISERS TO WITHIN 12" OF FIN. GRADE 96.0 27 ± LF OF 4" PVC PIPE SCHD 40 (ASTM D 1785 OR APPROVED EQUAL) MINIMUM SLOPE 1/4" PER FOOT 4 1 2 3 10 L.F. 4" PIPE - SDR 35AA ANTI-TRACKING PAD SIZE AND LOCATION TO BE DETERMINED IN FIELD AS CONDITIONS WARRANT (SEE DETAIL) INSTALL & MAINTAIN SILT FENCE (TYP.) SILT FENCE EROSION & SEDIMENTATION CONTROL NOTES: PROPOSED TRENCH PROPOSED TRENCH 24.0' 24.0'24.0'24.0'LIMIT OF ORIGINAL HOUSE 9 5 94 94.8 PROPOSED CONTOUR94 GRADE TO DRAIN 95.8 40 500102030 DISTANCE IN FEET SECTION A-A Vertical Scale: 1" = 5' Horizontal Scale: 1"=10' 98 97 96 95 94 93 92 91 90 STRIPPED GROUND LINE/ EXCAVATION LIMIT APPROX. 12-13 INCH DEPTH 6" TOPSOIL MIN EXISTING GROUND 5'5' GEOMATRIX GST 6230 LEACHING UNITS (TYP) (SEE DETAIL)BOTTOM OF UNITS ELEV. 91.00 COMMON FILL 99 100 FIELD CAPACITY WILL BE REQUIRED. PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE 3. 4. 2. DEPTH TO RESTRICTIVE LAYER: 100" (TP 2) 5. 6. PERCOLATION RATE FOR DESIGN: 6.7 min./inch THE DESIGN SHOWN HEREON CONFORMS TO ALL APPLICABLE STATE AND LOCAL HEALTH AGAINST FAILURE DUE TO IMPROPER INSTALLATION, IMPROPER MAINTENANCE OR TO NATURAL PHENOMENA BEYOND THE SCOPE OF NORMAL FIELD INVESTIGATION. CODE REQUIREMENTS AND TO GOOD ENGINEERING PRACTICE. I CAN NOT GUARANTEE 1. PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANITARIAN. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT DESIGN NOTES: REQUIRED LEACHING AREA FOR 3 BEDROOM BUILDING = 495 SF ELA #200 0-3#40 0-1.5 CONSTRUCTION SEQUENCE A. STRIP & STOCKPILE TOPSOIL FROM LEACHING AREA. B. CONSTRUCT LEACHING UNITS TO DESIGN LINE & GRADE. D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING. SEPTIC SYSTEM CONSTRUCTION NOTES: THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 5. 4. 2. 3. 0-5 0-10 20-55 90-100 100 PERCENT PASSING (BY WEIGHT) APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO. 4 STONE: THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR. BENCHMARK TO BE SET IN THE VICINITY OF THE LEACH FIELD AT THE TIME OF STAKEOUT. 7. 2-INCH 1-1/2-INCH 1-INCH 3/4-INCH 3/8-INCH SIEVE SIZE 6. 1. % PASSING: DRY SEIVE % PASSING: WET SEIVE SIEVE SIZE: 1. AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: LEACHING SYSTEM CONSTRUCTION NOTES: A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED 2. AND SPREAD AND COMPACTED WITH TRACK-DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA: NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO. 4 SIEVE. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN TRACK-DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO. 4 & 3" SIEVES) ** PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT. 3. #200 0-2.5 0-5 #10 70-100 70-100 0-510-75100 100 #4 **10-50 #40 0-20 #100 DESIGN: GEOMATRIX GST 6230 LEACHING UNITS ELA PROVIDED = 22.1 SF/LF x 25 LF = 552.5 SF ELA ROBERT W. HELLSTROM, L.S. #13626TO MY KNOWLEDGE AND BELIEF, THIS MAP ISSUBSTANTIALLY CORRECT AS NOTED HEREON.DATE:SHEET NO.:2 OF 2MAY 5, 2021BY:AGSSCALE:JOB NO.:FILE NO.:ALL RIGHTS RESERVEDANY REPRODUCTION, POSSESSION OR USE OF THIS DRAWING OR ANY PART THEREOFWITHOUT THE WRITTEN PERMISSION OF THE SURVEYOR INDICATED BELOW IS PROHIBITED.VIOLATORS WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW.HELLSTROMSURVEYING@YAHOO.COMREYNOLDS ENGINEERING SERVICES, LLC 63 NORWICH AVE. COLCHESTER, CT 06415 (860) 465-7419 (NOT TO SCALE) 100° SET POSTS / EXCAVATE 6" X 6" TRENCH / SET POST DOWNSLOPE/STAPLE WIRE MESH CANTED 10° INTO SLOPE SET 8' TO 10' APART, AND INTO GRADE 12" MIN., 2" X 4" X 5' STAKES DRIVEN FENCING TO POSTS / ATTACH FILTER BACKFILL TRENCH / COMPACT EXCAVATED SOIL FABRIC TO FENCING / EXTEND INTO TRENCH BACKFILL FLOW WIRE FENCING FILTER FABRIC 6" TO 8" WIDE 6" TO 8" DEEP TRENCH CUT FOLD FABRIC UP SLOPE COMPACTED 25' MIN. CRUSHED GRAVEL CT. D.O.T. 2"EXISTING ROAD/DRIVERADIUS 6" DEPTH MIN. NOT TO SCALE (CUT FOR 4" OVERFLOW) 4" PVC ELBOW STANDARD D-BOX W/ ELBOW1 1/4"1 1/2"1 3/4"NOT TO SCALE 8 3/4"4 1/2"2"2"10 3/4"2X2 5/8 16 GA. WIRE MESH 16"SOILS INFORMATION MLSS NEED NOT BE CONSIDERED - PREPARED FOR -MONTVILLE CONNECTICUTELISA & STEVEN PIERCE157 DOYLE ROAD UNIT BDETAILSAGS1" = 10'21-025_SitePlan2021-025Uncas Health District TP#1 0-12" Topsoil 12-26" Sandy Loam 26-112" Sand & Gravel, Cobbles Mottling: None Groundwater: 110" Ledge: None Roots: 28" PERCOLATION TEST DATE: 3/24/2021 HOLE DEPTH: 16" TIME DEPTH 2:46 FILL 3:32 DRY 3:33 6 3/8" REFILL 3:38 7 3/4" 3:43 9" 3:48 9 15/16" 3:53 10 1/2" 3:58 11 5/16" 4:03 11 7/8" 4:08 12 1/4" 4:13 13" 4:18 13 1/2" 4:23 14" 4:28 14 5/8" PERC RATE: 6.7 min./inch Date: March 24, 2021 Michael J. Kirby, R.S. Mark Reynolds, P.E. Restrictive: 110" TP#2 0-13" Topsoil 13-28" Sandy Loam 28-100" Sand & Gravel, Cobbles Mottling: None Groundwater: None Ledge: None Roots: 26" Restrictive: 100" 4:30 DRY Scale Drawn By: Date ACAD No. Sheet Of None REV. ERP 6/28/2007 32 C-04/28/09 Geo st ls Plan View.DWG GEOMATRIX ST LEACHING SYSTEM A-A' Cross Section Geomatrix Systems, LLC., Old Saybrook, CT 860-510-0730 Copyright 2009 GEOMATRIX SYSTEMS, LLC Patents Pending >2" 4"4" GEOMATRIX GST LEACHING SYSTEM A-A' CROSS SECTION Finished Grade shall be pitched to sheet flow stormwater away from system Cover material depth shall be >6" and shall be uniform over system Filter Fabric CT DOT No. 6 stone ASTM C-33 Sand (or approved equivilant) *H 18" (GST6218)*H= >2" TM Scale Drawn By: Date ACAD No. Sheet Of None REV. 6/28/2007 C-04/28/09 Geo GLS B-B'.DWG GEOMATRIX ST LEACHING SYSTEM B-B' Cross Section Geomatrix Systems, LLC., Old Saybrook, CT 860-510-0730 Copyright 2009 GEOMATRIX SYSTEMS, LLC Patents Pending GEOMATRIX GST LEACHING SYSTEM B-B' CROSS SECTION Finished Grade shall be pitched to sheet flow stormwater away from system Cover material depth shall be >6" and shall be uniform over system 18" (GST6218)*H= TM *P= 2" - 5.5" *3" min. I.D., ASTM D-3034, SDR 35 pipe for gravity applications 0.75" min. I.D., ASTM D-2665, SCH 40 PVC pipe for pressure applications *PDistribution Pipe* >2" *H ASTM C-33 Sand (or approved equivilant) CT DOT No. 6 stone Filter Fabric >2" 62" SEPTIC TANK 2 COMPARTMENT 1000 GALLON 53.75"57"66.5"1000 GAL CBACAPACITIES NOT TO SCALE CROSS SECTION 6 x 6 6/6 GA. WIRE MESH 4 x 4 12.6/12.6 GA. WIRE MESH INLET OUTLET 17 1/2"CBAASPHALT SEAL CONTINUOUS HOT LIQUID LEVEL PLAN OUTLET OPENINGS KNOCKOUT INLET AND CONCRETE COVERS CAST RIBS INSIDE21"4'-10"2'-5"8'-6"