HomeMy WebLinkAboutSite PlanU Z ZONING COMPLIANCE TABLE - ZONE R-1.20 ITEM. I REQUIRED I PROPOSED LOT AREA 120,000 S.F. 132,001 SF +/-(EX.) LOT FRONTAGE 200 FT. 226.42' FRONT YARD 60 FT, 83'+/ - SIDE YARD 25 FT. 43.4'+(DECK) REAR YARD 60 FT 750'+ BUILDI:NG HEIGHT 35 FT. 26 FT, W _ 0.4 i MAP'63 - LOT 001-001 0, r S 88036'34" W 338.73' LIMITS OF INLAND WETLANDS AS SHOWN j /,' ON APPROVED SUBDIVISION PLAN l \ r 25' d / TH#7 497 INSTALL &MAINTAIN A CONTINUOUyS-LINE OF SILT FENCE�(SEE DETAIL) i TH#5 rr - r % PT J / / 1 / i O PROPOSED r LIMITS OF / / e { i CJ1 { 1 CLEARING / ....................... / / LIMITS OF 50 / I UPLAND REVIEW AREA ............... : . r / kT l LIMITS'OF 5 / I C F EL 1 T ILL / .... ................................... .............. MAP 63 - LOT 001-002 SOIL TEST DATA PER SUBDIVISION MAP UNCAS HEALTH DISTRICT - 8/31/18 TH#5 - W-10" TOPSOIL TH#7 - W-12" TOPSOIL - 10"-16" SUBSOIL - 12"-31" SUBSOIL - 16"-28" GRAY COMP. SAND & SILT - 31 %100" MED./COARSE, TAN/BROWN SAND - 28"40" RED/BROWN COARSE SAND GW@100", NO LEDGE 40"-96" TAN FINE SAND ROOTS TO 42", MOTTLING - 31" GW@86", NO LEDGE ROOTS TO 25", MOTTLING - 23" TH#6 - 0"-7" TOPSOIL - 7"-21" SUBSOIL - 21"-106" GRAY COMP. SAND & SILT ROCKS & STONES GW@46", NO LEDGE ROOTS TO 34", MOTTLING - 21" a \ \ PROVIDE ANTI -TRACKING CONSTRUCTION DETAIL) PAD (S \ \ PROVIDE PAVED APRON TO STREETLINE �� •, a .--".,....,, ��� ��� a�I,b � / / '•, .✓^ �� � �" �t �� yak 1 -cx Q \ T / / - BL&P #463 \ s :PROPOSED " O i3l O/H UTILITIES sl 1 t ............................ .... r / /...............•.... ... ........ ' e: 109 COTTAGE ROAD .. . I y r�o n r AREA - 1 2 00 1 S F.� / ' % PROPOSED 3 �, rn r r�o l :::::::'::' 1 I LF-4'PVC c!1 cn WELL ........ - 3.03 ACRES+ Y `I' o 1 � (ASTM T D 1785 NV. I . .. / 499.00 / l ''........................... i / d { / f C� r' / TH#8 ,I / / / { x499.8 i r .: -.. / TIa#6 1 621/F-4"PVC -- ___ _ `-� / ' • INV N-498.10 (SDR35) NV.- OUT -498.00 498 74LF OF GEOMATRIX GST -6212 0 1� EXISTING GRADE @ SYSTEM - 496.75 '`�---- BOTTOM OF SYSTEM - 497.00 1,250 (2COMR. '_ '-- TOP OF SYSTEM - 498.00 �,- --- INV. 4" TOP DISTRIBUTION PIPE - 498.00 SEPTIC TANK -----.�.�, / INV. IN -498.75 / INV. OUT -498.5 , (SEE DETAIL) ' N 82004'571, W 771.67' \ LEGEND: A F.F. FIRST FLOOR EL. ELEVATION S.F. SQUARE FEET DH DRILL HOLE IPIN IRON PIN REC. RECOVERED x496.2 EXISTING SPOT ELEVATION x497.5 PROPOSED SPOT ELEVATION - - 496 - - EXISTING CONTOURS 496 PROPOSED CONTOURS BUILDING SETBACK LINE . TEST HOLE A I MAP 57 - LOT 011-001 ASTM C-33 SAPID SPECIFICATIONS: SIEVE SIZE PERCENT PASSING 0.375" 100 #4 95-100 #8 s0-100 #16 50-85 #30 25-60 #50 5-30 #100 <10 #200 <5 FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM / � 1 25' / J� O 6" MIN, COVER/ ­ 4 FILTER FABRIC OVER �/ kSTM C-33 SAND 4" 4" CT DOT #6 STONE ,T DOT #6 STONE ASTM C-33 SAND CROSS SECTION A -A � e A B C 1250 GAL 61" 51" z 1500 GAL •,.� 59" -f f A Sf a T.f ~fes ♦ .f�'y� • f� .1i" f Sf f f�� 1a��•a►�� 1 �, �� �•�ji.� �� erf��►,►�E,�.r 36'(GST 6236) \- CT DOT #6 STONE ASTM C-33 SAND CROSS SECTION B -B GEOMATRIX GST LEACHING SYSTEM TH#8 - 0"-8" TOPSOIL - V-21" SUBSOIL 21 "-98 GRAY COMP. SAND & SILT GW@78", NO LEDGE ROOTS TO 23", MOTTLING - 21" 1/C CONSTRUCTION ENTRANCE NOT TO SCALE 2/23/2021 ENGINFER DATE 14 , 01000 TO MY KNO LED. N • $ L AS NO'IrgD tH S LAP r aI`t a AND 'I KEMBQIBS��ED S" A.L 00 PERC TEST DATA PER SUBDIVISION MAP PERC (PRIMARY) DEPTH - 24" PRESOAK -10:53 11:35 - 8" 11:40 -16" 11:45 -181/2" 11:45 -23" 12:00 - 24 3/8" PERC RATE - 3.6 MINUTES PER INCH (PRIMARY PERC TEST) MLSS & DESIGN DATA 4 BEDROOM RESIDENCE AVG SLOPE - 1.5% PERC RATE - 1" IN 3,6 MINUTES RECEIVING SOIL DEPTH (AVG.) 24" SELECT FILL DEPTH AT SYSTEM - 15" TOTAL DEPTH AT SYSTEM - 39" RECEIVING SOIL DEPTH 25' DOWN GRADIENT (AVG.) 24" AVG. RECIEVING SOILS DEPTH - 39" + 24" = 62"/2 = 31.5" (HF) 42 X (FF) 1.75 X (PF) 1.0 = 73.5' MLSS REQUIRED - 73.5" MLSS PROVIDED 74' 4 BEDROOM HOUSE REQUIRES 495 + 82.5 = 577.5 S.F. OF EFFECTIVE LEACHING AREA USE 74 FEET OF GEOMATRIX-GST 6212 (12" DEPTH) (74 X 10.0 = 740 S.F.) USE 1,250 GAL. 2 COMPARTMENT SEPTIC TANK W/ OUTLET FILTER DEVICE R RESERVE AREA SAME AS PRIMARY „ 10 -6 KNOCKOUT 1NLEI" AND OUTLET OPENINGS Q tV 00 N II CAST CONCRETE COVERS PLAN CAPACITIES A B C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 56" 4 x 4 12.6/12.6 GA. WIRE MESH.' 17 1/2" 6 x 6 6/6 GA. WIRE MESH' LIQUID LEVEL_,-- p � CONTINUOUS HOT OUTLET ASPHALT SEAL FILTER 1" SCHED. #40 U DEVICE .T , CROSS SECTION , 1250/1500 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE 2X2 5/8 16 GA. WIRE MESH 1 1/2" �-!- � nl d^ Y' A e, STANDARD D -BOX FILTER FABRIC-___ � ANGLE 100 UP SLOPE POST FOR STABILITY AND SELF CLEANING H COMPACTED w RAC'KFTT.T, Q SILT FENCE NOT TO SCALE T-ATIS)MAP IS SUBSTANTIALLY CORRECT NOI YALID WITHOUT A LIVE SIGNATURE E SLMVEYOR HEREON. RICHARD A. DESCHAMPS L.S. #70019 DA 'E NOT TO SCALE EROSION AND SEDIMENT CONTROL PLAN: 1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE, 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES, 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR, 6. THE CONTRACTOR WILL B RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAW/HAY 70.90 lbs, FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 Ibs. FREE OF COARSE MATTER AIR DRIED, TREAT WITH PLANTING SCHEDULE: 121bs NITROGEN / TON SEEDING DATES: APRIL 1------- JUNE 15 AUGUST 1 ------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1, ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC 'TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED. LEACHING SYSTEM CONSTRUCTION NOTES: 1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL M ATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND LEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6 LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A, THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES. B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN N0.4 & 3 SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE, C. THE FILL LESS THE G SHALL MEET THE FOLLOWING S RAVEL S L EE H OL OWING GRADATIO CRITERIA: NC . SIEVE SIZE: #4 #10 #40 #100 #200 %PASSING: 100 70-100 **10-50 0-20 0-5 WET SIEVE / PASSING: 00 -100 10 0 1 70 75 0-5 0-2,5 DRY SIEVE o PERCENT PASSING THE #� 0 SI BE INCREASED • { r4 EVE CAN0 NO GREATER THAN 5 IFTHE E T 7 /o THE PERC NT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. 2, DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT; 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS T0 CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND SPREAD AND COMPACTED WITH TRACK -D RIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHIN G AREA IS NOT TO BE DISTURBED. SEPTIC SYSTEM CONSTRUCTION NOTES: 1. CONSTRUCTION SEQUENCE: A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA. B. PLACE SELECT FILL IF REQUIRED, C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING. 2, THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D 1785 SCHD 40 OR APPROVED EQUAL. 3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE, 5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT) 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 2O-55 3/4 -INCH 0-10 3/8 -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD .BY A LICENSED LAND SURVEYOR 8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 0" INTO EXISTING GRADE. NOTES: 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS, 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT, 3. BASE FOR LEVELS: APPROXIMATE MAN D. 1988, 4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-120. 5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL, AREA OF PROPERTY - 132,001 S.F,t (3.03 ACRES). 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION, REFERENCE MAP: SUBDIVISION PLAN PREPARED FOR STEPHEN & ELISA PIERCE, PROPOSED :GOTS 1 & 2 SITE DESIGN, 105 COTTAGE ROAD, MONTVILLE, CONNECTICUT,' SHT 2 OF 4, SCALE: 1"=40', DATE: SEPT. 26, 2018, REV. TO 1/25/19, PREPARED BY ROB HELLSTROM LAND SURVEYING, LLC. SEPTIC SYSTEM DESIGN PLAN PREPARED FOR 20 10 0 20 GRAPHIC SCALE IN FEET #109 COTTAGE ROAD MONTVILLE, CONNECTICUT ADVANCED SURVEYS, LLC. 25 Apple Lane, Colchester CT. 06415 Phone & Fax (860) 267-5979 N w E S v-, PROJECT NO*, 21-020 DRAWN BY,:,;' R.A.D. DATE: 2/16/21 SCALE: 1 "=20' SHEET 1 OF 1 REVISIONS EROSION AND SEDIMENT CONTROL PLAN: 1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE, 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES, 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR, 6. THE CONTRACTOR WILL B RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAW/HAY 70.90 lbs, FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 Ibs. FREE OF COARSE MATTER AIR DRIED, TREAT WITH PLANTING SCHEDULE: 121bs NITROGEN / TON SEEDING DATES: APRIL 1------- JUNE 15 AUGUST 1 ------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1, ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC 'TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED. LEACHING SYSTEM CONSTRUCTION NOTES: 1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL M ATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND LEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6 LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A, THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES. B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN N0.4 & 3 SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 SIEVE, C. THE FILL LESS THE G SHALL MEET THE FOLLOWING S RAVEL S L EE H OL OWING GRADATIO CRITERIA: NC . SIEVE SIZE: #4 #10 #40 #100 #200 %PASSING: 100 70-100 **10-50 0-20 0-5 WET SIEVE / PASSING: 00 -100 10 0 1 70 75 0-5 0-2,5 DRY SIEVE o PERCENT PASSING THE #� 0 SI BE INCREASED • { r4 EVE CAN0 NO GREATER THAN 5 IFTHE E T 7 /o THE PERC NT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%. 2, DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT; 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS T0 CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND SPREAD AND COMPACTED WITH TRACK -D RIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHIN G AREA IS NOT TO BE DISTURBED. SEPTIC SYSTEM CONSTRUCTION NOTES: 1. CONSTRUCTION SEQUENCE: A. STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA. B. PLACE SELECT FILL IF REQUIRED, C. CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE D. LOAM, FINE GRADE TO FINISHED GRADE AND SEED. PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING. 2, THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D 1785 SCHD 40 OR APPROVED EQUAL. 3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE, 5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6. APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT) 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 2O-55 3/4 -INCH 0-10 3/8 -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD .BY A LICENSED LAND SURVEYOR 8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 0" INTO EXISTING GRADE. NOTES: 1. TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS, 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT, 3. BASE FOR LEVELS: APPROXIMATE MAN D. 1988, 4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R-120. 5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL, AREA OF PROPERTY - 132,001 S.F,t (3.03 ACRES). 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION, REFERENCE MAP: SUBDIVISION PLAN PREPARED FOR STEPHEN & ELISA PIERCE, PROPOSED :GOTS 1 & 2 SITE DESIGN, 105 COTTAGE ROAD, MONTVILLE, CONNECTICUT,' SHT 2 OF 4, SCALE: 1"=40', DATE: SEPT. 26, 2018, REV. TO 1/25/19, PREPARED BY ROB HELLSTROM LAND SURVEYING, LLC. SEPTIC SYSTEM DESIGN PLAN PREPARED FOR 20 10 0 20 GRAPHIC SCALE IN FEET #109 COTTAGE ROAD MONTVILLE, CONNECTICUT ADVANCED SURVEYS, LLC. 25 Apple Lane, Colchester CT. 06415 Phone & Fax (860) 267-5979 N w E S v-,