Loading...
HomeMy WebLinkAboutSite PlanCG.1JJa,— ZONING COMPLIANCE TABLE - WRP-160 DISTRICT ITEM � REQUIRED PROPOSED LOT AREA 160,000 S.F. 217,085 SF LOTFRONTAGE 200 FT. 517.94' FRONT YARD 75 FT. 85'+/ - SIDE YARD 30 FT. 35' (DECK) REAR YARD 75 FT. 400'+ ,j BUILDING HEIGHT 35 FT. 26 FT. w CLEAR ALL VEGETATION, STONEWALLS AND GRADE TO NEW STREETLINE ALONG EAST LAKE ROAD AS ��� �\ j // \ \ • \ \ r - REQUIRED TO ACHIEVE 280' ��p `---' — — -- � � ( \\ \ SNS SIGHT DISTANCES (TYP.) #264 S 35051'05" E 1 45.55 i \ 1 0���\ // / i/ \\\\ e fes...---- i7 20rL1,1`Z PROVIDE NON -TRACKING CONSTRUCTION ENTRANCE (TYP.) (SEE DETAIL) \ \ i r / / SNE' \ `PROPOSED PAVED DRIVEWAY APRON \ / i #2644 \ \ \ LIMITS OF ~ CLEARING O ° c° S) G � _.., _ ROPOSED o ° orE\� WELL ` o o Orli C i 00o 00 0�,: - - _ `'//`. •., "' \ r70 00 \ \ / V . -- PROPOSED_ — _' — — — �. .._, —• ` — . � - PROVIDE \ / — - — DRIVEWAY ' .. ETON S 50046'20"E_ \ SHOULDER ` — _,, — _ ,.-- — - ,/` -_.. _ — .._. ..,, -•.-. 6 \ i — 49:53'" 1 274 • (SEE DETAIL) _ SNET I /' S 63°0.8,1.1 E — _ _ _ _ `F QTING #2645 / I I?ySTA_LL A CONTINUOUS DRAIN_ OUTLET 39.36 r .. LI1NE_OF SILT_FENCE .� \ G --(SEE DETAIL) e - -"'` _1,-40 40 42LF QF GEOMATRIX GST=62-18 / = '� *` EXISTING GRADE @ SYSTEM - 264:6 _ ' ` ti�- 272 0 �)� BOTTOM OJE SYSTEM-- 266.10 TOP OF-SISTEM - 263.60 STH#9A \ \ 46LF-4"PVC� INYI 4" TOP DISTRIBUTION PIPE - 263`6.Q ` \ \\ \ j�'�(ASTM D1785) 14LF-4"PVC TH#9C (SDR -35) LIMITS OF \ o 50' WETLANDS -REVIEW AREA \ \ \TH#9D 26p'-/ - _ _ _ �• .. \\ 1\ \ D BOX- 1,250 (2COMP.) f \ \ 1 INV. IN -263.80 SEPTIC TANK N 26 LIMITS OF 1 1 W/RISERS \ I ' 1 INV. OUT -263.70 — , WL#45INLAND \ I I 1 INV. IN 265.75 °Q g WETLANDS 1 1 INV. OU\T-265.50 W \ - SEE DETAIL)/J. '266 • r — 26 \/ ��V i• \\ .i5 la , LEGEND: PERC TEST DATA F.F. FIRST FLOOR EL, ELEVATION S.F. SQUARE FEET DH DRILL HOLE IPIN IRON PIN REC. RECOVERED x276.5 EXISTING SPOT ELEVATION x274.5 PROPOSED SPOT ELEVATION — — 276 — — EXISTING CONTOURS n PROPOSED CONTOURS - 48"-78" GRAY SANDY TILL BUILDING SETBACK LINE NO WATER, NO MOTTING, NO LEDGE TEST HOLE a� \iw \ i 260 SOIL TEST DATA PERC TEST DATA WITNESSED BY MICHAEL KIRBY 11 I I I I UNCAS HEALTH DISTRICT - 7/18/18 PERC #9 DEPTH - 26" TH#9A - 0"-2" TOPSOIL PRESOAK - 8:35 - DRY AT 9:25 - 2"44" BROWN FINE SANDY LOAM 9:35 - 5" - 44"-92" GRAY SANDY TILL 9:45 -10" NO WATER, NO MOTTING, NO LEDGE 9:55 - 141/4" 10:05 -16 3/4" TH#9B - 0"4" TOPSOIL 10:15 -181/4" - 4"-48" BROWN FINE SANDY LOAM 10:25 - 19 1/2" 10:35 - 20 1/2" - 48"-78" GRAY SANDY TILL NO WATER, NO MOTTING, NO LEDGE PERC RATE - 9 MINUTES PER INCH TH#9C - 0"-3" TOPSOIL - Y-48" BROWN FINE SANDY LOAM - 48"-78" GRAY SANDY TILL NO WATER, NO MOTTING, NO LEDGE MLSS & DESIGN DATA TH#9D - 0"-6" TOPSOIL - 6"48" BROWN FINE SANDY LOAM MLSS - NOT REQUIRED - 48"-77" GRAY SANDY TILL PERC RATE - 1" IN 9 MINUTES NO WATER, MOTTING@60", NO LEDGE 4 BEDROOM HOUSE REQUIRES 577.5 SY, OF EFFECTIVE LEACHING AREA USE 42 FEET OF GEOMATRIX-GST 62128 (18" DEPTH) (42 X 14.0 = 588 S.F.) USE 1,250 GAL. 2 COMPARTMENT SEPTIC TANK W/ OUTLET FILTER DEVICE i t� w 2X2 5/8 16 GA. WIRE MESH 1 1/2' 1 00 2" (-- STANDARD D -BOX NOT TO SCALE FILTER FABRIC ANGLE 100 UP SLOPE POST FOR STABILITY AND 1aoo SELF CLEANING COMPACTED BACKFILL SILT FENCE + NOT TO SCALE CAST CONCRETE COVERS PLAN CAPACITIES AB C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 56" %4 x 4 12.6/12.6 GA. WIRE MESH 117 1/2", / /— 6 x 6 6/6 GA. WIRE MESH CONNUUS HO=4 V�" A PHALOSEAL T CROSS SECTION . 1250/1500 GALLON 7 rn'hA'P A R T"KAPXTT NOT TO SCALE N A N CONSTRUCTION ENTRANCE NOT TO SCALE ASTM C-33 SAND SPECIFICATIONS: SIEVE SIZE PERCENT PASSING 0.375" 100 #4 95-100 #8 80-100 #16 50-85 #30 25-60 #50 5-30 #100 <10 #200 <5 FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM 6" MIN. COVER FILTER FABRIC OVER SYSTEM '' •i :ti J. `: ASTM C-33 SAND +' •' CT DOT #6 STONE CT DOT #6 STONE ASTM C-33 SAND CROSS SECTION A—A — DISTRIBUTION PIPE 6" MIN. FILTER FABRIC A H = 6" (GST 6206) p , 12" (GST 6212) 18" (GST 6218) 36" (GST 6236) \-•• CT DOT #6 STONE ASTM C-33 SAND CROSS SECTION B—B GEOMATRIX GST LEACHING SYSTEM `ems • r;`� /'s ETO MY` - r AND 13 ) LIEF, THIS MAP IS SUBSTANTIALLY CORRECT S fHIS IS OT VALID WITHOUT A LIVE SIGNATURE _ (SSE 'SEA O T SURVEYOR HEREON. o k69 f RICHAAD A. DESCHAMPS L.S. #70019 DATE EROSION AND SEDIMENT CONTROL PLAN: 1, CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM, 2, DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE, 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE, TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAWMAY 70-90 lbs. FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 lbs, FREE OF COARSE MATTER AIR DRIED, TREAT WITH PT .ANTTNC, CC'NFTIT U .F.• 12lbs NITROGEN / TON SEEDING DATES: APRIL 1------- NNE 15 AUGUST 1------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1, ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN, IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED, LEACHING SYSTEM CONSTRUCTION NOTES: 1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING, FILL MATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: ® A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES, B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN N0, 4 & 3" SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE N0, 4 SIEVE, C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA: SIEVE SIZE: #4 #10 #40 #100 #200 %.PASSING: 100 70-100 **10.50 0-20 0-5 WET SIEVE % PASSING: 100 70-100 10-75 0-5 0-15 DRY SIEVE PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%, 2, DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT, 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION, NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND OUTLET SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED, OUTLET FILTER U DEVICE SEPTIC SYSTEM CONSTRUCTION NOTES: 1, CONSTRUCTION SEQUENCE: A, STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA. B, PLACE SELECT FILL IF REQUIRED, C, CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE. D, LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING, 2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL. 3• ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. 5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6, APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT) 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 20-55 3/4 -INCH 0-10 3/$ -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR, 8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 30" INTO EXISTING GRADE. NOTES: 1, TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT• 3. BASE FOR LEVELS: N.A,V.D.1988. 4, PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT WRP-160. 5, THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL AREA OF PROPERTY - 217,085 S.F,± (4,98 ACRES). i 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION, REFERENCE MAP: SUBDIVISION PLAN PREPARED FOR SUNMAR/RAF BUILDERS, LLC, #1100 EAST LAKE ROAD, MONTVILLE, CONNECTICUT, SCALE: 1"=100', DATE: 10/2/18, REV. TO 12/16/19, ALL SHEETS, PREPARED BY ADVANCED SURVEYS, LLC. lv-v KNOCKOUT INLET AND OUTLET OPENINGS CV 11 I I I I � N L!__1 Ll CAST CONCRETE COVERS PLAN CAPACITIES AB C 1250 GAL 61" 51" 48" 1500 GAL 69" 59" 56" %4 x 4 12.6/12.6 GA. WIRE MESH 117 1/2", / /— 6 x 6 6/6 GA. WIRE MESH CONNUUS HO=4 V�" A PHALOSEAL T CROSS SECTION . 1250/1500 GALLON 7 rn'hA'P A R T"KAPXTT NOT TO SCALE N A N CONSTRUCTION ENTRANCE NOT TO SCALE ASTM C-33 SAND SPECIFICATIONS: SIEVE SIZE PERCENT PASSING 0.375" 100 #4 95-100 #8 80-100 #16 50-85 #30 25-60 #50 5-30 #100 <10 #200 <5 FINISH GRADE TO DIRECT RUNOFF AWAY FROM SYSTEM 6" MIN. COVER FILTER FABRIC OVER SYSTEM '' •i :ti J. `: ASTM C-33 SAND +' •' CT DOT #6 STONE CT DOT #6 STONE ASTM C-33 SAND CROSS SECTION A—A — DISTRIBUTION PIPE 6" MIN. FILTER FABRIC A H = 6" (GST 6206) p , 12" (GST 6212) 18" (GST 6218) 36" (GST 6236) \-•• CT DOT #6 STONE ASTM C-33 SAND CROSS SECTION B—B GEOMATRIX GST LEACHING SYSTEM `ems • r;`� /'s ETO MY` - r AND 13 ) LIEF, THIS MAP IS SUBSTANTIALLY CORRECT S fHIS IS OT VALID WITHOUT A LIVE SIGNATURE _ (SSE 'SEA O T SURVEYOR HEREON. o k69 f RICHAAD A. DESCHAMPS L.S. #70019 DATE EROSION AND SEDIMENT CONTROL PLAN: 1, CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE DRIVEWAY AND SEPTIC SYSTEM, 2, DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE, 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE, TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAWMAY 70-90 lbs. FREE FROM WEEDS AND COARSE MATTER WOOD CHIPS 185-275 lbs, FREE OF COARSE MATTER AIR DRIED, TREAT WITH PT .ANTTNC, CC'NFTIT U .F.• 12lbs NITROGEN / TON SEEDING DATES: APRIL 1------- NNE 15 AUGUST 1------ SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES: 1, ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN, IN THE EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED, LEACHING SYSTEM CONSTRUCTION NOTES: 1, TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING, FILL MATERIAL BETWEEN AND BEYOND TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED AND COMPACTED IN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: ® A. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES, B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN N0, 4 & 3" SIEVES) NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE N0, 4 SIEVE, C, THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA: SIEVE SIZE: #4 #10 #40 #100 #200 %.PASSING: 100 70-100 **10.50 0-20 0-5 WET SIEVE % PASSING: 100 70-100 10-75 0-5 0-15 DRY SIEVE PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IF THE PERCENT PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%, 2, DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT, 3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION, NO TRAFFIC OTHER THAN TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILL AREA AFTER TOPSOIL REMOVAL, FILL MATERIAL TO BE DUMPED AT THE EDGE OF THE STRIPPED AREA AND OUTLET SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED, OUTLET FILTER U DEVICE SEPTIC SYSTEM CONSTRUCTION NOTES: 1, CONSTRUCTION SEQUENCE: A, STRIP & STOCKPILE TOPSOIL FROM LEACHING TRENCH AREA. B, PLACE SELECT FILL IF REQUIRED, C, CONSTRUCT LEACHING TRENCH TO DESIGN LINE & GRADE. D, LOAM, FINE GRADE TO FINISHED GRADE AND SEED, PROTECT DISTURBED AREAS WITH EROSION CONTROLS UNTIL FIRST MOWING, 2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA HEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL. 3• ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SET LEVEL ON A MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. 5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6, APPROVED STONE AGGREGATE FOR LEACHING TRENCHES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT) 2 -INCH 100 1 -1/2 -INCH 90-100 1 -INCH 20-55 3/4 -INCH 0-10 3/$ -INCH 0-5 7. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR, 8. THE BOTTOM OF THE LEACHING TRENCHES NOT TO EXCEED MORE THAN 30" INTO EXISTING GRADE. NOTES: 1, TOPOGRAPHIC INFORMATION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT• 3. BASE FOR LEVELS: N.A,V.D.1988. 4, PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT WRP-160. 5, THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL AREA OF PROPERTY - 217,085 S.F,± (4,98 ACRES). i 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION, REFERENCE MAP: SUBDIVISION PLAN PREPARED FOR SUNMAR/RAF BUILDERS, LLC, #1100 EAST LAKE ROAD, MONTVILLE, CONNECTICUT, SCALE: 1"=100', DATE: 10/2/18, REV. TO 12/16/19, ALL SHEETS, PREPARED BY ADVANCED SURVEYS, LLC.