Loading...
HomeMy WebLinkAboutArchitectual Plan140.0' 140.0' 138.0' 136.0' 138.0' 135.0' 136.0' 135.0' 141.0' 1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME 2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR DOORS 3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS OTHERWISE NOTED). 4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66 IT IS CENTERED ON WALL. 5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO THE STRUCTURE. 6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE SECURED TO STRUCTURE. 7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST RATED PARTITION SHALL CONTINUE THROUGH. 8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL SUPPORT. 9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS. 10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES 11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001. 12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS. 13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7 SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS TO HAVE OPENING LIMITATION FEATURES. 1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL PROTECTION 2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS 3.12" COUNTER OVERHANG 4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE BLOCKING AS REQUIRED 5.CLOSET ROD AND SHELF 6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING AND PAINT. DIVISION 2 - SITE WORK 1.SITE PREPARATION. DEMOLITION AND REMOVAL OF SITE DEBRIS, INCLUDING CLEARING VEGETATION AND ADHERE TO ALL LOCAL, STATE AND FEDERAL REGULATIONS REGARDING REMOVAL OF LANDSCAPING MATERIALS. 2.UTILITIES: UTILITY TRENCHING AND ALL NEW CONNECTIONS TO BE COORDINATED WITH THE OWNER AND SUBCONTRACTORS TO TIE INTO TOWN UTILITIES. DIVISION 03 - CONCRETE: 1.CAST-IN-PLACE CONCRETE - REFER TO STRUCTURAL NOTES FOR MIX DESIGNS AND REQUIREMENTS - STANDARD REINFORCED CONCRETE STRIP FOOTINGS - SITE CAST CONCRETE FOUNDATION WALLS - CONCRETE SLABS ON GRADE FOUNDATION FOOTING DRAINS TO BE 6" DIAMETER SCHEDULE 20 PVC WITH 3/8" DIAMETER HOLES AT 6" O.C. SET IN GRAVEL WITH GEOTEXTILE FABRIC SILT COVER LET TO DAYLIGHT AT SOUTH SIDE OF STRUCTURE. DIVISION 05 - METALS: 1.ROOF GUTTERS AND LEADERS 5" K STYLE ALUMINUM GUTTERS WITH 0.032" GA GUTTERS, 0.027" GA DOWNSPOUTS. ANCHORS, HANGERS END CAPS BY ENGLER, INC OR EQUAL. DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES: 1.ROUGH CARPENTRY - REFER TO STRUCTURAL FOR SPECIFICATIONS - WOOD STUD CAVITY WALL CONSTRUCTION - ENGINEERED WOOD BEAM, JOISTS AND POSTS - WOOD STAIRS - METAL PLATE-CONNECTED WOOD TRUSSES - SHEATHING - SUBFLOOR AND ROOF PLYWOOD SHEATHING 2.METAL FRAMING CONNECTIONS FOR JOISTS AND BEAMS. BY SIMPSON OR APPROVED EQUAL. 3.SILL SEALER GASKET AT ALL SILL PLATES. VENTILATE BUILDING FULLY AFTER EXPOSURE TO WATER SO THAT WOOD DRIES COMPLETELY PRIOR TO ENCLOSURE. 4.PRESSURE TREATED WOOD. PT WATER BORNE SALT PRESERVATIVES PER AWPB STANDARDS, 040#/CF- ACQ. 5.EXTERIOR TRIM- PT WOOD WRAPPED IN PRE-FINISHED ALUMINUM COIL STOCK OR PVC EXTERIOR TRIM. 6.EXERIOR SIDING TO BE VINYL SIDING 7.STAIRS - ALL INTERIOR UNIT STAIRS TO BE WOOD FRAMED CONSTRUCTION 8.INSULATE ALL WINDOW CAVITIES AND SURROUNDS. 9.EXTERIOR PORCHES. PRESSURE TREATED STRUCTURAL ELEMENTS INCLUDING PVC DECKING, RAILING AND TRIM INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 10.INTERIOR STAIR RAILINGS - BEACH, NATURAL FINISH HANDRAIL, 1-1/2" DIAMETER 11.INTERIOR FINISH CARPENTRY - STANDING AND RUNNING TRIM - CLOSET ROD AND SHELF IN ALL BEDROOMS CASEWORK - ALL CASEWORK (SUBJECT TO OWNER DECISION) - CLOSET ROD AND SHELF IN ALL BEDROOMS 12.CASEWORK - ALL CASEWORK (SUBJECT TO OWNER DECISION) - KITCHEN WALL AND BASE CABINETS AND COUNTERTOPS - BATH VANITY BASE CABINETS AND COUNTERTOPS DIVISION 07- THERMAL AND MOISTURE PROTECTION: 1.DAMPPROOFING AND WATERPROOFING SPRAY-APPLIED BITUMINOUS 2.ROOF SLOPING 30 YEAR ASPHALT DIMENSIONAL SHINGLES, GAF TIMBERLINE SELECT 40FLASHING PTD. .032 AND .040 ALUMINUM MISC. SHAPES WINDOW HEAD/SILL/JAMB: MODIFIED BITUMEN FLASHING VYCOX, PERMOBARRIER OR APPROVED EQUAL. INSTALL TWO LAYERS SEVERE EXPOSURE FLASHING SYSTEM VINYL FLASHING: 0.032" ALUMINUM WALL FLASHING ALL HORIZONTAL EXTERIOR JOINTS 3.INSULATION UNDER SLAB INSULATION: 2" EPS RIGID INSULATION (R FOR 24" AT PERIMETER FOR ALL SLABS ON GRADE WITH 1" THERMAL BREAK OF AT PERIMETER FOUNDATION WALL 1" RIGID INSULATION AT ALL OTHER AREAS OF SLAB ON GRADE FOUNDATION INSULATION: R-133 INSULATION ALL FOUNDATION WALLS FOR OCCUPIED SPACES. SOUND ATTENUATION AND FIRE RESISTIVE INSULATION - REFER TO DRAWINGS (PARTITION SCHEDULES AND DETAILS FOR SPECIFICATIONS VAPOR RETARDERS/BARRIERS POLYETHYLENE SLAB VAPOR BARRIER BATH WALL INSULATION (DAMP BLOWN CELLULOSE INSULATION HOT WATER SUPPLY LINES: 1" ARMAFLEX RIGID FIBERGLASS INSULATION. AIR INFILTRATION BARRIER: EXTERIOR WALLS AND SOFFITS. TYVEK COMMERCIAL GRADE BY DUPONT OR APPROVED EQUAL. TAPE ALL SEAMS AND PENETRATIONS INCLUDING TERMINATIONS AT ROOF, WINDOWS AND DOORS. 4.JOINTS AND SEALANTS: FIRE RATED SEALANTS - PROVIDE AS REQUIRED AT ALL RATED WALL PENETRATIONS. EXTERIOR JOINTS - PROVIDE SEALANTS FOR INTERIOR APPLICATIONS TO MAINTAIN AIRTIGHT AND WATER-RESISTANT SEALS. ALL INTERIOR SEALANTS MUST COMPLY WIT LOW VOC REQUIREMENTS SPRAY FOAM: INSTALL MINIMALLY EXPANDING SPRAY FOAM INSULATION TO SEAL AND INSULATE ALL DOORS, WINDOWS AND FRAMING JOINTS. 5.DOORS, WINDOWS DOORS IN BETWEEN GARAGE AND UNITS/LAUNDRY ROOMS: 1-3/4", 16 GAUGE, HOT DIPPED GALVANIZED, 6 PANEL INSULATED AND FIRE RATED (20 MINUTES) UNIT INTERIOR DOORS: PRE-PRIMED PRE-HUNG 6-PANEL HARDBOARD DOOR HARDWARE: REFERENCE DRAWING A6.0 FOR HARDWARE SCHEDULE 6.SIDING - VINYL SIDING 4" T.W. - VENTED AND SOLID SOFFIT - FASCIA /EAVES - MISC. ALUMINUM AND PVC TRIM AND REVEAL PROFILES 7. VINYL WINDOWS - CASEMENT AND FIXED PANE TYPE WINDOWS - PERFORMANCE VALUES TO MEET THOSE INDICATED ANDERSEN SILVERLIGHT AS BASIS FOR DESIGN 8.GLAZING MEET THOSE INDICATED ANDERSEN SILVERLIGHT AS BASIS FOR DESIGN 8.GLAZING - ALL BUILDING ENVELOPE GLAZING TO COMPLY W/ PERFORMANCE VALUES - DOUBLE GLAZED SYSTEMS TO BE ARGON FILLED - SAFETY GLAZING AS SCHEDULED - LOUVERS AND VENTS - REFER TO MECHANICAL - COORDINATE PAINTING EXTERIOR GRILLES AND VENTS WITH SIDING AND EXTERIOR MATERIAL COLORS DIVISION 09 - FINISHES: 1.GYPSUM BOARD ASSEMBLIES REFERENCE DRAWING A-001 NON-PAPER FACED BOARD AT BATHROOM WALLS AND CEILING, LAUNDRY ROOMS AND MECHANICAL ROMS. CEMENT BOARD: DUROCK AT ALL BATHROOMS BEHIND SHOWER SURROUNDS 2. RESILIENT FLOORING - UNIT BATHROOMS - ARMSTRONG CONNECTION CORLON OR EQUAL - UNIT LIVING ROOMS , KITCHENS, AND HALLWAYS - VINYL PLANK FLOORING 3. PAINTING PAINT: ALL WALL AND CEILING LOCATIONS. PAINT TO BE LOW VOC LATEX PRIMERS AND COATINGS. SHEEN VARIES. PROVIDE MILDICIDE ADDITIVES AT KITCHENS AND BATHROOMS. PAINT: ALL EXTERIOR METALS. PAINT TO BE ALKYD BASED, SEMI GLOSS. GALVANIZED METAL ELEMENTS TO BE SHOP PRIMED. TNEMEC AT EXTERIOR RAILINGS AS APPLICABLE. INTERIOR PAINT: CEILING - 1 COAT LATEX PRIMER, 1 COAT FLAT CEILING PAINT WALLS - 1 COAT LATEX PRIMER, 2 COATS LATEX EGGSHELL KITCHENS, BATHROOMS - 1 COAT LATEX PRIER, 2 COATS SEMI-GLOSS ALKYD ENAMEL. FERROUS METAL - 1 COAT RUST-INHIBITING PRIMER, 1 COAT ENAMEL UNDERCOAT, 1 COAT SEMI GLOSS ALKYD ENAMEL EXTERIOR PAINT WOOD SIDING 1 COAT FACTORY PRIER ALL SIDES, 2 COATS SEMI GLOSS ALKYD ENAMEL DIVISION 11 - EQUIPMENT: 1. RESIDENTIAL APPLIANCES - SELECTIONS BY OWNER DIVISION 12 - FURNISHING 1.SIGNAGE - FIRE DEPARTMENT REQUIRE D BUILDING IDENTIFICATION - DIMENSIONAL BUILDING LETTERS 2.TOILET AND BATH ACCESSORIES - TOILET TISSUE DISPENSER CHROME TOWEL BARS CHROME ROBE HOOKS CURVED SHOWER CURTAIN ROD AT ALL TUBS 3.FIRE PROTECTION SPECIALTIES - FIRE EXTINGUISHERS - (1) 5 LB. DRY CHEMICAL EXTINGUISHER W/ HANGER PER DWELLING UNIT, DIVISION 15 - MECHANICAL DIVISION 16 - ELECTRICAL ELECTRICAL SYSTEM: PROVIDE 100 AMP SERVICE TO EACH UNIT. EXTERIOR BUILDING/SITE LIGHTING: ALL SITE LIGHTING SHALL BE FULL CUTOFF FIXTURES TELEPHONE/CATV DOOR BELLS UNIT LIGHTING BASEMENT LEVEL FLOOR PLAN A-100 1 1/4" = 1'-0" BASEMENT FLOOR PLAN GENERAL SHEET NOTES PLAN TAGS GENERAL SPECIFICATIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL COMPARABLE CONDITIONS. THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC. (860) 460-6188 kathy.kmlarchitects@gmail.com kmlarchitects.com p e w 171 Branch Hill Road a Preston, CT 06365-8605 Revisions No Date Description PROPOSED TOWNHOUSES ROGER & LINDA PHILLIPS GRASSY HILL ROAD MONTVILLE CONNECTICUT 101 7'-1"14'-11"60'-0" 1'-4" 20'-0" 11'-0"6'-9"2'-3" 102 101 7'-1"14'-11"103 104 2'-0" 11'-0"6'-9"2'-3" 4'-3" 6'-012"8'-278"3'-11"4'-012"4'-412"10'-218"12'-834" 3'-1118"2'-87 8"11'-1158"1'-6"102 101 103 104 6'-9"2'-3" 6'-012"8'-278"3'-11"10'-218"12'-9" 3'-1118"2'-87 8"12'-0" 20'-0" 1'-4" 5'-6"5'-6"1'-6"4'-3"4'-012"4'-412"102 103 104 6'-012"8'-278"3'-11"4'-012"4'-412"10'-218"12'-83 4" 3'-1118"2'-87 8"11'-1158" 8"6'-612"6'-612"8"6'-612"6'-612"8"8" 20'-0" 4'-3"8"8"6'-612"6'-612"8" 44 5 1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME 2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR DOORS 3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS OTHERWISE NOTED). 4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66 IT IS CENTERED ON WALL. 5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO THE STRUCTURE. 6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE SECURED TO STRUCTURE. 7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST RATED PARTITION SHALL CONTINUE THROUGH. 8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL SUPPORT. 9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS. 10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES 11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001. 12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS. 13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7 SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS TO HAVE OPENING LIMITATION FEATURES. 1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL PROTECTION 2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS 3.12" COUNTER OVERHANG 4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE BLOCKING AS REQUIRED 5.CLOSET ROD AND SHELF 6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING AND PAINT. 72"52"40"22"5"32"34"48"10"10"8" 2012"4712"4712"46"46"4812"10" 46" 72"52"40"22"5"32"34"48"10"10"8" 2012"4712"4712"46"46"4812"10" 46" 4 FIRST FLOOR PLAN A-101 1 1/4" = 1'-0" FIRST FLOOR PLAN GENERAL SHEET NOTES PLAN TAGS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL COMPARABLE CONDITIONS. THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC. (860) 460-6188 kathy.kmlarchitects@gmail.com kmlarchitects.com p e w 171 Branch Hill Road a Preston, CT 06365-8605 Revisions No Date Description PROPOSED TOWNHOUSES ROGER & LINDA PHILLIPS GRASSY HILL ROAD MONTVILLE CONNECTICUT 2 3/8" = 1'-0" ENLARGED PLAN 3 3/8" = 1'-0" ENLARGED PLAN 60'-0" 20'-0"12'-7"203 20'-0" 6'-10"6'-878"4'-9"3'-11"10'-218"14'-834"4'-1"1'-6"20'-0" 3'-1118"7'-018"5'-7"8'-278" 2'-107 8"4'-312" 6'-5"6'-10" 6'-878" 6'-5" 203 6'-1014"6'-878"4'-9"3'-11"10'-218"14'-914"4'-1" 3'-1118"7'-018"5'-7"8'-278" 2'-107 8"4'-312" 6'-5"12'-7"203 4'-9"3'-11"10'-218"14'-83 4"4'-1" 3'-1118"7'-018"5'-7"8'-278" 2'-107 8"4'-312" 1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME 2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR DOORS 3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS OTHERWISE NOTED). 4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66 IT IS CENTERED ON WALL. 5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO THE STRUCTURE. 6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE SECURED TO STRUCTURE. 7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST RATED PARTITION SHALL CONTINUE THROUGH. 8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL SUPPORT. 9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS. 10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES 11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001. 12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS. 13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7 SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS TO HAVE OPENING LIMITATION FEATURES. 1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL PROTECTION 2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS 3.12" COUNTER OVERHANG 4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE BLOCKING AS REQUIRED 5.CLOSET ROD AND SHELF 6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING AND PAINT.4712"4712"46"4712"4712"46"4812"10"10" 46" 4812"10" 46"46"46"24"60" 48"38"33"34"38"42"24"60" 48"38"33"34"38"42"41" SECOND FLOOR PLAN A-102 1 1/4" = 1'-0" SECOND FLOOR PLAN GENERAL SHEET NOTES PLAN TAGS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL COMPARABLE CONDITIONS. THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC. (860) 460-6188 kathy.kmlarchitects@gmail.com kmlarchitects.com p e w 171 Branch Hill Road a Preston, CT 06365-8605 Revisions No Date Description PROPOSED TOWNHOUSES ROGER & LINDA PHILLIPS GRASSY HILL ROAD MONTVILLE CONNECTICUT 2 3/8" = 1'-0" ENLARGED PLAN 3 3/8" = 1'-0" ENLARGED PLAN 2 1/8" = 1'-0" EXTERIOR ELEVATION BUILDING ELEVATIONS A-201 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL COMPARABLE CONDITIONS. THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC. (860) 460-6188 kathy.kmlarchitects@gmail.com kmlarchitects.com p e w 171 Branch Hill Road a Preston, CT 06365-8605 Revisions No Date Description PROPOSED TOWNHOUSES ROGER & LINDA PHILLIPS GRASSY HILL ROAD MONTVILLE CONNECTICUT 1 1/4" = 1'-0" EXTERIOR ELEVATION 3 1/8" = 1'-0" EXTERIOR ELEVATION 4 1/8" = 1'-0" EXTERIOR ELEVATION