HomeMy WebLinkAboutArchitectual Plan140.0'
140.0'
138.0'
136.0'
138.0'
135.0'
136.0'
135.0'
141.0'
1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME
2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR
DOORS
3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS
OTHERWISE NOTED).
4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66
IT IS CENTERED ON WALL.
5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO
THE STRUCTURE.
6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE
SECURED TO STRUCTURE.
7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST
RATED PARTITION SHALL CONTINUE THROUGH.
8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED
EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL
SUPPORT.
9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS.
10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES
11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001.
12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS.
13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY
ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7
SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS
TO HAVE OPENING LIMITATION FEATURES.
1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL
PROTECTION
2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS
3.12" COUNTER OVERHANG
4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE
BLOCKING AS REQUIRED
5.CLOSET ROD AND SHELF
6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH
CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING
AND PAINT.
DIVISION 2 - SITE WORK
1.SITE PREPARATION. DEMOLITION AND REMOVAL OF SITE DEBRIS,
INCLUDING CLEARING VEGETATION AND ADHERE TO ALL LOCAL, STATE AND
FEDERAL REGULATIONS REGARDING REMOVAL OF LANDSCAPING
MATERIALS.
2.UTILITIES: UTILITY TRENCHING AND ALL NEW CONNECTIONS TO BE
COORDINATED WITH THE OWNER AND SUBCONTRACTORS TO TIE INTO
TOWN UTILITIES.
DIVISION 03 - CONCRETE:
1.CAST-IN-PLACE CONCRETE - REFER TO STRUCTURAL NOTES FOR MIX
DESIGNS AND REQUIREMENTS
- STANDARD REINFORCED CONCRETE STRIP FOOTINGS
- SITE CAST CONCRETE FOUNDATION WALLS
- CONCRETE SLABS ON GRADE
FOUNDATION FOOTING DRAINS TO BE 6" DIAMETER SCHEDULE 20 PVC WITH
3/8" DIAMETER HOLES AT 6" O.C. SET IN GRAVEL WITH GEOTEXTILE FABRIC
SILT COVER LET TO DAYLIGHT AT SOUTH SIDE OF STRUCTURE.
DIVISION 05 - METALS:
1.ROOF GUTTERS AND LEADERS 5" K STYLE ALUMINUM GUTTERS WITH 0.032"
GA GUTTERS, 0.027" GA DOWNSPOUTS. ANCHORS, HANGERS END CAPS BY
ENGLER, INC OR EQUAL.
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES:
1.ROUGH CARPENTRY - REFER TO STRUCTURAL FOR SPECIFICATIONS
- WOOD STUD CAVITY WALL CONSTRUCTION
- ENGINEERED WOOD BEAM, JOISTS AND POSTS
- WOOD STAIRS
- METAL PLATE-CONNECTED WOOD TRUSSES
- SHEATHING
- SUBFLOOR AND ROOF PLYWOOD SHEATHING
2.METAL FRAMING CONNECTIONS FOR JOISTS AND BEAMS. BY SIMPSON OR
APPROVED EQUAL.
3.SILL SEALER GASKET AT ALL SILL PLATES. VENTILATE BUILDING FULLY
AFTER EXPOSURE TO WATER SO THAT WOOD DRIES COMPLETELY PRIOR
TO ENCLOSURE.
4.PRESSURE TREATED WOOD. PT WATER BORNE SALT PRESERVATIVES PER
AWPB STANDARDS, 040#/CF- ACQ.
5.EXTERIOR TRIM- PT WOOD WRAPPED IN PRE-FINISHED ALUMINUM COIL
STOCK OR PVC EXTERIOR TRIM.
6.EXERIOR SIDING TO BE VINYL SIDING
7.STAIRS - ALL INTERIOR UNIT STAIRS TO BE WOOD FRAMED CONSTRUCTION
8.INSULATE ALL WINDOW CAVITIES AND SURROUNDS.
9.EXTERIOR PORCHES. PRESSURE TREATED STRUCTURAL ELEMENTS
INCLUDING PVC DECKING, RAILING AND TRIM INSTALLED IN ACCORDANCE
WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS.
10.INTERIOR STAIR RAILINGS - BEACH, NATURAL FINISH HANDRAIL, 1-1/2"
DIAMETER
11.INTERIOR FINISH CARPENTRY
- STANDING AND RUNNING TRIM
- CLOSET ROD AND SHELF IN ALL BEDROOMS
CASEWORK - ALL CASEWORK (SUBJECT TO OWNER DECISION)
- CLOSET ROD AND SHELF IN ALL BEDROOMS
12.CASEWORK - ALL CASEWORK (SUBJECT TO OWNER DECISION)
- KITCHEN WALL AND BASE CABINETS AND COUNTERTOPS
- BATH VANITY BASE CABINETS AND COUNTERTOPS
DIVISION 07- THERMAL AND MOISTURE PROTECTION:
1.DAMPPROOFING AND WATERPROOFING
SPRAY-APPLIED BITUMINOUS
2.ROOF
SLOPING 30 YEAR ASPHALT DIMENSIONAL SHINGLES, GAF TIMBERLINE
SELECT 40FLASHING PTD. .032 AND .040 ALUMINUM MISC. SHAPES
WINDOW HEAD/SILL/JAMB: MODIFIED BITUMEN FLASHING VYCOX,
PERMOBARRIER OR APPROVED EQUAL. INSTALL TWO LAYERS SEVERE
EXPOSURE FLASHING SYSTEM
VINYL FLASHING: 0.032" ALUMINUM WALL FLASHING ALL HORIZONTAL
EXTERIOR JOINTS
3.INSULATION
UNDER SLAB INSULATION: 2" EPS RIGID INSULATION (R FOR 24" AT
PERIMETER FOR ALL SLABS ON GRADE WITH 1" THERMAL BREAK OF AT
PERIMETER FOUNDATION WALL 1" RIGID INSULATION AT ALL OTHER AREAS
OF SLAB ON GRADE
FOUNDATION INSULATION: R-133 INSULATION ALL FOUNDATION WALLS FOR
OCCUPIED SPACES.
SOUND ATTENUATION AND FIRE RESISTIVE INSULATION - REFER TO
DRAWINGS (PARTITION SCHEDULES AND DETAILS FOR SPECIFICATIONS
VAPOR RETARDERS/BARRIERS
POLYETHYLENE SLAB VAPOR BARRIER
BATH WALL INSULATION (DAMP BLOWN CELLULOSE INSULATION
HOT WATER SUPPLY LINES: 1" ARMAFLEX RIGID FIBERGLASS INSULATION.
AIR INFILTRATION BARRIER: EXTERIOR WALLS AND SOFFITS. TYVEK
COMMERCIAL GRADE BY DUPONT OR APPROVED EQUAL. TAPE ALL SEAMS
AND PENETRATIONS INCLUDING TERMINATIONS AT ROOF, WINDOWS AND
DOORS.
4.JOINTS AND SEALANTS:
FIRE RATED SEALANTS - PROVIDE AS REQUIRED AT ALL RATED WALL
PENETRATIONS. EXTERIOR JOINTS - PROVIDE SEALANTS FOR INTERIOR
APPLICATIONS TO MAINTAIN AIRTIGHT AND WATER-RESISTANT SEALS. ALL
INTERIOR SEALANTS MUST COMPLY WIT LOW VOC REQUIREMENTS
SPRAY FOAM: INSTALL MINIMALLY EXPANDING SPRAY FOAM INSULATION
TO SEAL AND INSULATE ALL DOORS, WINDOWS AND FRAMING JOINTS.
5.DOORS, WINDOWS
DOORS IN BETWEEN GARAGE AND UNITS/LAUNDRY ROOMS: 1-3/4", 16
GAUGE, HOT DIPPED GALVANIZED, 6 PANEL INSULATED AND FIRE RATED (20
MINUTES)
UNIT INTERIOR DOORS: PRE-PRIMED PRE-HUNG 6-PANEL HARDBOARD
DOOR HARDWARE: REFERENCE DRAWING A6.0 FOR HARDWARE SCHEDULE
6.SIDING
- VINYL SIDING 4" T.W.
- VENTED AND SOLID SOFFIT
- FASCIA /EAVES
- MISC. ALUMINUM AND PVC TRIM AND REVEAL PROFILES
7. VINYL WINDOWS
- CASEMENT AND FIXED PANE TYPE WINDOWS - PERFORMANCE VALUES TO
MEET THOSE INDICATED ANDERSEN SILVERLIGHT AS BASIS FOR DESIGN
8.GLAZING
MEET THOSE INDICATED ANDERSEN SILVERLIGHT AS BASIS FOR DESIGN
8.GLAZING
- ALL BUILDING ENVELOPE GLAZING TO COMPLY W/ PERFORMANCE VALUES
- DOUBLE GLAZED SYSTEMS TO BE ARGON FILLED
- SAFETY GLAZING AS SCHEDULED
- LOUVERS AND VENTS - REFER TO MECHANICAL
- COORDINATE PAINTING EXTERIOR GRILLES AND VENTS WITH SIDING AND
EXTERIOR MATERIAL COLORS
DIVISION 09 - FINISHES:
1.GYPSUM BOARD ASSEMBLIES
REFERENCE DRAWING A-001
NON-PAPER FACED BOARD AT BATHROOM WALLS AND CEILING, LAUNDRY
ROOMS AND MECHANICAL ROMS.
CEMENT BOARD: DUROCK AT ALL BATHROOMS BEHIND SHOWER
SURROUNDS
2. RESILIENT FLOORING
- UNIT BATHROOMS - ARMSTRONG CONNECTION CORLON OR EQUAL
- UNIT LIVING ROOMS , KITCHENS, AND HALLWAYS - VINYL PLANK FLOORING
3. PAINTING
PAINT: ALL WALL AND CEILING LOCATIONS. PAINT TO BE LOW VOC LATEX
PRIMERS AND COATINGS. SHEEN VARIES. PROVIDE MILDICIDE ADDITIVES
AT KITCHENS AND BATHROOMS.
PAINT: ALL EXTERIOR METALS. PAINT TO BE ALKYD BASED, SEMI GLOSS.
GALVANIZED METAL ELEMENTS TO BE SHOP PRIMED. TNEMEC AT
EXTERIOR RAILINGS AS APPLICABLE.
INTERIOR PAINT:
CEILING - 1 COAT LATEX PRIMER, 1 COAT FLAT CEILING PAINT
WALLS - 1 COAT LATEX PRIMER, 2 COATS LATEX EGGSHELL
KITCHENS, BATHROOMS - 1 COAT LATEX PRIER, 2 COATS SEMI-GLOSS
ALKYD ENAMEL.
FERROUS METAL - 1 COAT RUST-INHIBITING PRIMER, 1 COAT ENAMEL
UNDERCOAT, 1 COAT SEMI GLOSS ALKYD ENAMEL
EXTERIOR PAINT
WOOD SIDING 1 COAT FACTORY PRIER ALL SIDES, 2 COATS SEMI GLOSS
ALKYD ENAMEL
DIVISION 11 - EQUIPMENT:
1. RESIDENTIAL APPLIANCES
- SELECTIONS BY OWNER
DIVISION 12 - FURNISHING
1.SIGNAGE
- FIRE DEPARTMENT REQUIRE D BUILDING IDENTIFICATION
- DIMENSIONAL BUILDING LETTERS
2.TOILET AND BATH ACCESSORIES -
TOILET TISSUE DISPENSER
CHROME TOWEL BARS
CHROME ROBE HOOKS CURVED SHOWER CURTAIN ROD AT ALL TUBS
3.FIRE PROTECTION SPECIALTIES
- FIRE EXTINGUISHERS
- (1) 5 LB. DRY CHEMICAL EXTINGUISHER W/ HANGER PER DWELLING UNIT,
DIVISION 15 - MECHANICAL
DIVISION 16 - ELECTRICAL
ELECTRICAL SYSTEM: PROVIDE 100 AMP SERVICE TO EACH UNIT.
EXTERIOR BUILDING/SITE LIGHTING: ALL SITE LIGHTING SHALL BE FULL
CUTOFF FIXTURES
TELEPHONE/CATV
DOOR BELLS
UNIT LIGHTING
BASEMENT LEVEL
FLOOR
PLAN
A-100
1 1/4" = 1'-0"
BASEMENT FLOOR PLAN
GENERAL SHEET NOTES
PLAN TAGS
GENERAL SPECIFICATIONS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER
WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO
BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL
COMPARABLE CONDITIONS.
THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC
AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS
PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART
OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER
WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC.
(860) 460-6188
kathy.kmlarchitects@gmail.com
kmlarchitects.com
p
e
w
171 Branch Hill Road a
Preston, CT 06365-8605
Revisions
No Date Description
PROPOSED
TOWNHOUSES
ROGER & LINDA
PHILLIPS
GRASSY HILL ROAD
MONTVILLE
CONNECTICUT
101
7'-1"14'-11"60'-0"
1'-4"
20'-0"
11'-0"6'-9"2'-3"
102
101
7'-1"14'-11"103
104
2'-0"
11'-0"6'-9"2'-3"
4'-3"
6'-012"8'-278"3'-11"4'-012"4'-412"10'-218"12'-834"
3'-1118"2'-87 8"11'-1158"1'-6"102
101
103
104
6'-9"2'-3"
6'-012"8'-278"3'-11"10'-218"12'-9"
3'-1118"2'-87 8"12'-0"
20'-0"
1'-4"
5'-6"5'-6"1'-6"4'-3"4'-012"4'-412"102
103
104
6'-012"8'-278"3'-11"4'-012"4'-412"10'-218"12'-83 4"
3'-1118"2'-87 8"11'-1158"
8"6'-612"6'-612"8"6'-612"6'-612"8"8"
20'-0"
4'-3"8"8"6'-612"6'-612"8"
44
5
1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME
2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR
DOORS
3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS
OTHERWISE NOTED).
4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66
IT IS CENTERED ON WALL.
5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO
THE STRUCTURE.
6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE
SECURED TO STRUCTURE.
7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST
RATED PARTITION SHALL CONTINUE THROUGH.
8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED
EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL
SUPPORT.
9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS.
10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES
11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001.
12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS.
13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY
ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7
SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS
TO HAVE OPENING LIMITATION FEATURES.
1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL
PROTECTION
2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS
3.12" COUNTER OVERHANG
4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE
BLOCKING AS REQUIRED
5.CLOSET ROD AND SHELF
6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH
CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING
AND PAINT.
72"52"40"22"5"32"34"48"10"10"8"
2012"4712"4712"46"46"4812"10"
46"
72"52"40"22"5"32"34"48"10"10"8"
2012"4712"4712"46"46"4812"10"
46"
4
FIRST
FLOOR
PLAN
A-101
1 1/4" = 1'-0"
FIRST FLOOR PLAN
GENERAL SHEET NOTES
PLAN TAGS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER
WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO
BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL
COMPARABLE CONDITIONS.
THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC
AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS
PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART
OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER
WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC.
(860) 460-6188
kathy.kmlarchitects@gmail.com
kmlarchitects.com
p
e
w
171 Branch Hill Road a
Preston, CT 06365-8605
Revisions
No Date Description
PROPOSED
TOWNHOUSES
ROGER & LINDA
PHILLIPS
GRASSY HILL ROAD
MONTVILLE
CONNECTICUT
2 3/8" = 1'-0"
ENLARGED PLAN 3 3/8" = 1'-0"
ENLARGED PLAN
60'-0"
20'-0"12'-7"203
20'-0"
6'-10"6'-878"4'-9"3'-11"10'-218"14'-834"4'-1"1'-6"20'-0"
3'-1118"7'-018"5'-7"8'-278"
2'-107 8"4'-312"
6'-5"6'-10"
6'-878"
6'-5"
203
6'-1014"6'-878"4'-9"3'-11"10'-218"14'-914"4'-1"
3'-1118"7'-018"5'-7"8'-278"
2'-107 8"4'-312"
6'-5"12'-7"203 4'-9"3'-11"10'-218"14'-83 4"4'-1"
3'-1118"7'-018"5'-7"8'-278"
2'-107 8"4'-312"
1.EXTERIOR FRAMING DIMENSIONS ARE FRAME TO FRAME
2.EXTERIOR OPENING DIMENSIONS ARE TO CENTERLINE OF WINDOWS OR
DOORS
3.INTERIOR DIMENSIONS INDICATED ARE TO (FACE OF STUD UNLESS
OTHERWISE NOTED).
4./2&$7('22523(1,1*6´)5201($5(673(53(1',&8/$5:$//81/(66
IT IS CENTERED ON WALL.
5.FIRE AND SOUND RATED WALLS/PARTITIONS TO BE CONSTRUCTED TIGHT TO
THE STRUCTURE.
6.PIPING, DUCTWORK AND OTHER PENETRATIONS. ALL WORK IS TO BE
SECURED TO STRUCTURE.
7.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST
RATED PARTITION SHALL CONTINUE THROUGH.
8.INSTALL BLOCKING IN PARTITIONS FOR CASEWORK, WALL MOUNTED
EQUIPMENT, TRIM, STAIRS AND HANDRAILS AS REQUIRED FOR STRUCTURAL
SUPPORT.
9.SEE PARTITION DETAILS ON A-001 FOR REQUIRED FIRE SEPARATION WALLS.
10.SEE SHEET A-601 FOR DOOR AND WINDOW SCHEDULES
11.WALL TAG LETTERS REFER TO WALL TYPES AS SCHEDULE ON A-001.
12.SEE STRUCTURAL DRAWINGS FOR SLAB DEPRESSIONS AND CUTOUTS.
13.SLEEPING ROOMS SHALL HAVE AT LEAST ON OPERABLE EMERGENCY
ESCAPE AND RESCUE WINDOW WITH A MINIMUM CLEAR OPENING OF 5.7
SQ.FT. COORDINATE WITH PLANS AND WINDOW MANUFACTURER. WINDOWS
TO HAVE OPENING LIMITATION FEATURES.
1.HANDRAIL AND BALUSTERS AS REQUIRED FOR FALL
PROTECTION
2.DROPPED BEAM REFER TO STRUCTURAL DRAWINGS
3.12" COUNTER OVERHANG
4.CLOSET WITH 5 WOOD SHELVES EQUALLY SPACED PROVIDE
BLOCKING AS REQUIRED
5.CLOSET ROD AND SHELF
6.22"X30" ATTIC ACCESS PANEL. TEXTURE AND PAINT TO MATCH
CEILING. TRIM FINISHED OPENING WITH SOFT WOOD CASING
AND PAINT.4712"4712"46"4712"4712"46"4812"10"10"
46"
4812"10"
46"46"46"24"60"
48"38"33"34"38"42"24"60"
48"38"33"34"38"42"41"
SECOND
FLOOR
PLAN
A-102
1 1/4" = 1'-0"
SECOND FLOOR PLAN
GENERAL SHEET NOTES
PLAN TAGS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER
WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO
BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL
COMPARABLE CONDITIONS.
THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC
AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS
PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART
OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER
WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC.
(860) 460-6188
kathy.kmlarchitects@gmail.com
kmlarchitects.com
p
e
w
171 Branch Hill Road a
Preston, CT 06365-8605
Revisions
No Date Description
PROPOSED
TOWNHOUSES
ROGER & LINDA
PHILLIPS
GRASSY HILL ROAD
MONTVILLE
CONNECTICUT
2 3/8" = 1'-0"
ENLARGED PLAN 3 3/8" = 1'-0"
ENLARGED PLAN
2 1/8" = 1'-0"
EXTERIOR ELEVATION
BUILDING
ELEVATIONS
A-201
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND RELATIONS TO OTHER
WORK BEFORE FABRICATION AND/OR INSTALLATION. DRAWINGS ARE NOT TO
BE SCALED. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
ALL NOTES ON THIS DRAWING ARE TYPICAL AND APPLY EQUALLY TO ALL
COMPARABLE CONDITIONS.
THESE DRAWINGS ARE COPY RIGHT PROPERTY OF KML ARCHITECTS , LLC
AND HAVE BEEN SPECIFICALLY PREPARED FOR THE OWNER OF THIS
PROJECT AT THIS SITE, AND ARE NOT TO BE DUPLICATED OR USED IN PART
OR WHOLE FOR ANY OTHER PURPOSE, PROJECT LOCATION OR OWNER
WITHOUT THE EXPRESS WRITTEN CONSENT OF KML ARCHITECTS, LLC.
(860) 460-6188
kathy.kmlarchitects@gmail.com
kmlarchitects.com
p
e
w
171 Branch Hill Road a
Preston, CT 06365-8605
Revisions
No Date Description
PROPOSED
TOWNHOUSES
ROGER & LINDA
PHILLIPS
GRASSY HILL ROAD
MONTVILLE
CONNECTICUT
1 1/4" = 1'-0"
EXTERIOR ELEVATION
3 1/8" = 1'-0"
EXTERIOR ELEVATION
4 1/8" = 1'-0"
EXTERIOR ELEVATION