Loading...
HomeMy WebLinkAboutSite PlanLEGEND: VOL, PG, N/F S.F. MS DH IP REC. CL&P - - 410410 - - N/F RONALD J. CAPOZZA & KAREN J. CARPOZZA VOL. 175 PG. 1058 (MAP 57 - LOT 25) (EAST LYME) VOLUME PAGE NOW OR FORMERLY SQUARE FEET MERESTONE DRILL HOLE IRON PIPE RECOVERED CONNECTICUT LIGHT & POWER EXISTING CONTOURS PROPOSED CONTOURS BUILDING SETBACK LINE TEST HOLE PERC TEST DATA PER ADVANCED SURVEYS - 7/3/19 PERC DEPTH - 23" PRESOAK - 9:30 - DRY AT 10:20 10:30 - 7" 10:40 -101/2" 10:50 -13 1/2" 11:00 -16" 11:10 -18" 11:20 -191/2" 11:30 - 201/2" PERC RATE - 8 MINUTES PER INCH N/F PETER KOLODNICKI, ET AL VOL. 624 PG. 407 (MAP 11 -, LOT 46) TEST HOLE DATA WITNESSED BY MICHAEL KIRBY - UNCAS HEALTH DEPARTMENT 7/3/19 TH #1 0"-9" TOPSOIL & SURFACE BOULDERS 9"40" LOAMY SUBSOIL 40"-75" MED: GRAY TIGHT SAND SOME' SILT & ROCKS NO LEDGE, MOTTLING@3811, NO GROUNDWATER ROOTS TO 40" TH #2 0"-8" TOPSOIL & SURFACE BOULDERS K-27" LOAMY SUBSOIL 27"-78" MED. GRAY SAND & ROCKS NO LEDGE, NO MOTTLING, NO GROUNDWATER ROOTS TO 27" TH #3 0"-8" TOPSOIL & SURFACE BOULDERS 9"-30" LOAMY SUBSOIL 30"-77" MED. GRAY SAND & ROCKS NO LEDGE, NO MOTTLING, NO GROUNDWATER ROOTS TO 22" TH #4 0"-8" TOPSOIL & SURFACE BOULDERS 8"-21" LOAMY SUBSOIL 21 "-66" MED, GRAY SAND & ROCKS NO LEDGE, MOTTLING@29", GROUNDWATER@60" ROOTS TO 24" EXISTING SEPTIC SYSTEM (3) ROWS - 55' LONG - 4' WIDE STONE TRENCHES lv-'7/1045113 " E NOTES PER 1000 S.F. 55'x3x3 = 495' ELA STRAWMAY 70-90 lbs. 88.3 _ 90,945 SF +/- (EXIST.) AND COARSE MATTER rrf2\ FREE OF COARSE MATTER FRONT YARD SEPTIC SYSTEM RESERVE AREA PLANTING SCHEDULE: N g001810 , Aon SEEDING DATES: PERC RATE: 8 MIN. PER INCH APRIL 1------- JUNE 15 1106 4p4 AUGUST 1------ SEPTEMBER 15 SLOPE - 14.8% SEED MIXTURE: -RESTRICTIVE WL# 1,4 DH \ �i� got Llk ,P9 X96 ` ,-� - 29" 3 BEDROOM RESIDENCE 45% KENTUCKY BLUE GRASS _- « 10% PERENNIAL RYE BY 24 x FF 1.5 PF 1.0 = 36 ^ � . x IV/ i - ,133.871 `` I �/ { 3 BEDROOM HOUSE REQUIRES 495 S.F. WL# 13 i.-''' �REC. Y _ OF EFFECTIVE LEACHING AREA 4\ REC\ USE 50LF OF GEOMTRIX GST 6212 #12 >^ �_ `. 0 4 \ N 4'5.,03 00' E \` (50 x 10 = 500 S.F.) \ 27 72� ` USE 1,000 GAL. 2 COMPARTMENT SEPTIC TANK \ \ \ W/ OUTLET FILTER DEVICE �_I I T 2 TH#1 \', -✓ '�, \L h / J 1 RESRVE AREA ( \ WL#10 � PT tij ) 99 l � I 7 TH#3 i 2II#4 i ® t- �! EXIST. J , ` �/) > > �) ( J WELL ( v WOODLINE i 20 1 i \ C \ ( \ N/F LIMITS OF<� NICHOLAS HARKINS INLAND WETLANDS 1 PROVI�E A CONTINUOUS 1 �. '�� VOL. 594 PG. 242 LINE OF SILT FENCE j (, SE DtTAIL ) ( 1 'C t (MAP 11 - LOT 43-F) Y! PROVIDV, 1 000GAL./2C MP. ) l ( SEPTC TAN ,> L#4' ' ` �L �' rj I (SEE DETA W .. *SET TA' 1� TO EX�STINGi PIPE EL ATION r < ( EXISTING t \ ( �1 lot1 1WL#2B l WL#1 / \ } B t I GARAGE \ 1 l \; V�L#3 `/ ti �' 30LF-4' PVC �I� `�� ) �1 (ASTM D'1785) WLR 3Bs .�. t / LIMITS OF F .. . INLAND WETLANDS r L I ) 7B #2 WI -MB `WL#613 EXI TINGWL#1 0� l_ 2PAVED \ \ \ \ DRIVEWAY PROPOSED \ �\ I \ 1 <} PN RESIDENCE17 1/ F.F.-421.0 <� °�� ,77777���� 77777X, (REMOVE) EXISTING ` _ ` D-08°21'34`/ \ < t RESIDENCE tESi DE�CE \,EXI�S4T.-SEPTICITAENDK.l587.756' 9TO, BE ABANDONt-85.75 S PER HEALTHCODE REC. .> 9 3 4 0' R60'" ` D-85. 5601 { S 6404 '48" W 171.41' l �� I \ y -=,'`- �, '25MPH > ( UTILITIES v I d ,/ � >#9610SIGN 1/2 ) < <r �� 'HOLMES ROAD oo • 1p t < l #6893 ' 1, h 25MPH UPOLE � SIGN ® CL&P HELTCO � I #6894 #9610 ro `rod, d >O rl EROSION AND SEDIMENT CONTROL PLAN: 1, CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE AND SEPTIC TANK. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED, 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE. 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES, 5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. PROVIDED STRAWMAY 70-90 lbs. FREE FROM WEEDS 90,945 SF +/- (EXIST.) AND COARSE MATTER WOOD CHIPS 185-2751bs. FREE OF COARSE MATTER FRONT YARD AIR DRIED, TREAT WITH PLANTING SCHEDULE: 12lbs NITROGEN / TON SEEDING DATES: 212.0' PROPOSED HOUSE APRIL 1------- JUNE 15 15 FT. AUGUST 1------ SEPTEMBER 15 SIDE YARD (EAST) SEED MIXTURE: 177.4' PROPOSED HOUSE 45% RED FESCUE I 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE LOCATION MAP 1000 500 0 1000 8'-6" GRAPHIC SCALE IN FEET KNOCKOUT INLET AND OUTLET OPENINGS RIBS INSIDE - + N + CAST CONCRETE COVERS 4 x 4 12.6/12.6 GA. WIRE MESH 6 x 6 6/6 GA. WIRE MESH 17 1 /2" 4., INLE 3" VENT --�� e 3" VENT -� OUTLET ' LIQUID LEVEL OUTLET CONTINUOUS HOT 14" OUTLET 1 FILTER BAFFLE ASPHALT SEAL LINED WITH DEVICE d- 4" SCHEDULE #40 1/8" PVC �n INLET BAFFLE 600 GAS `* DEFLECTOR Q' . --. •�""�•' . Q' 'QTc-• -`. T-• '.-�''o' 41J51-81? r I I If 3 CROSS SECTION 1000 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE FILTER II FABRIC ANGLE 100 UP SLOPE POST I FOR STABILITY AND o SELF CLEANING COMPACTED I' �A BACKFILL U l SILT FENCE NOT TO SCALE \0kililliflfilllll i 'U TO VY XN VE D AS MTEk RICHARD A. DESCHAMPS IEF, THIS MAP IS SUBSTANTIALLY CORRECT IS NOT, VALID WITHOUT A LIVE SIGNATURE THE SURVEYOR HEREON. 1 r'- L.S. #70019 DTE NOTES: 1. THIS SURVEY HAS BEEN PREPARED PURSUANT TO THE REGULATIONS OF CONNECTICUT STATE AGENCIES SECTIONS 20 -300b -I THROUGH 2O -300b-20 AND THE "STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON SEPTEMBER 26,1996. IT IS A PROPERTY SURVEY BASED ON A RESURVEY AND CONFORMS TO HORIZONTAL ACCURACY CLASS A-2. 2. FOR SUBJECT PROPERTY REFERENCE IS MADE TO THE TOWN OF MONTVILLE LAND RECORDS VOLUME 513 - PAGE 472. 3. TOTAL AREA OF PROPERTY - 90,945 SQUARE FEET± (2.09 ACRES±). 4. THE PROPERTY IS SHOWN ON ASSESSORS MAP 11- LOT 43. 5. THE PROPERTY IS LOCATED IN ZONING DISTRICT R-40, 6. TOPOGRAPHC INFORMATION COMPLIES WITH T-2 MAPPING STANDARDS. BASE FOR LEVELS: APPROXIMATE N.A.V.D. 1988. 7. THE PROPERTY IS SERVICED BY AN ON-SITE SEPTIC SYSTEM & WELL. 8. EXISTING SEPTIC SYSTEM LOCATION SHOWN PER SKETCHES PROVIDED BY THE UNCAS HEALTH DISTRICT. EXISTING SEPTCI SYSTEM INSTALLED ON 6/7/03. 9. LIMITS OF INLAND WETLANDS WERE DELINEATED BY MARK H, SULLIVAN C.P.S.S. ON MAY 6, 2019. MAP REFERENCE: WILLIAM J. HUDYMA SUBDIVISION - HOLMES ROAD, MONTVILLE, CT., SCALE: 1"=-40', DATE MARCH 8,1983, PREPARED BY KING & MULLEN, LAND SURVEYORS. SITE DATA TABLE - ZONE R-40 ITEM REQUIRED PROVIDED LOT AREA 40,000 S.F. 90,945 SF +/- (EXIST.) LOT FRONTAGE 150 FT. 325.99' FRONT YARD 40 FT. 16.9' EXISTING & PROPOSED HOUSE REAR YARD 40 FT, 212.0' PROPOSED HOUSE SIDE YARD (WEST) 15 FT. 103.4' PROPOSED HOUSE SIDE YARD (EAST) 15 FT. 177.4' PROPOSED HOUSE BUILDING HEIGHT 35 FT. 26'