Loading...
HomeMy WebLinkAboutSite PlanI--- Ile W tiv / i / - - - - • °o' F \ t 1 1 t - rr FSISF--- Ir f, f12' DRIVE s ' PROPS41SO , !, 4 BED' HC1 1250 G)L. / j EPTIG TAW-, 2 Zl T TH14G r 4/' / uF LLFt 000, TLAND auFFIER \ \ 1 PROPOSED \1 s i \ \ \\ `LF y WELL IF U4 014 I M 6" SOIL COVER MIN.) FIN15H GRADE NON -WOVEN FILTER FABRIC OVER STONE 4" PVC PERFORATED PLASTIC 015TR15UTION PIPE (ASTM D 3033) ONE INCH CLEAN BROKEN 2" STONE OR SCREENED GRAVEL 12" T INVERT 45" WIDTH 15" MOTTLING LINE 12" x 48" LEACHING TRENCH - NOT TO SCALE F®OTINCa DRAIN . SEPTIC SYSTEM DESIGN LOT 14 PRIMARY SYSTEM: ADDITIONAL TEST HOLES REQUIRED IN PRIMARY AND RESERVE AREAS. . F PERCOLATION RATE: 1 TO 10 MIN./INCH 4 5EDROOM HOUSE i ! \ EFFECTIVE LEACHING AREA REQUIRED = 660 SF SER,E SYSTEM ) USE A 12" DEEP x 45" WIDE TRENCH ` EFFECTIVE LEACHING AREA OF TRENCH = 3 SF/LF LENGTH OF TRENCH REQUIRED = (660 SFX3 SF/LF) = 220 LF Q 11 9 - \ SLOPE = 596 { DEPTH TO RESTRICTIVE LAYER = 44" - \ H.F.=30 F.F=2.0 P.F.= 1.2 MI -55 REQUIRED = 12 LF USE THREE ROWS OF 15' AT V O.C. LEACHING AREA PROVIDED = r015 aF f' RESERVE SYSTEM: USE SAME DESIGN AS PRIMARY 5Y6TEM LOT 14 -PERCOLATION TEST DATA TOTAL DEPTH 26" FWE50AK AT 839 13" TEST HOLES RECORDED 5Y AMANDA ACHMATOW 4 R05ERT RUSSO 9:40 - 14.15" Q,q TH1 4F TH14E S4 J 7H14C s , 4A * TH #1 105" TOTAL DEPTH 0" - 9" TOPSOIL 9"-25" SU55O1L 25"-54" FINE SAND S4"-69" MEIN. COMP FINE SAND 4 SILT 69"-108" MEDIUM COARSE GRAVEL, ROCKS 3 ;ROWS OF 15 LF / NO 15EDROCK AO4 LNG TRENCHES NO WATERL25" MOTTLING TH 014F 101" TOTAL DEPTH V-10" TOPSOIL 10'- 34"SU5601L 34"-10" MED. COMP. FINE SAND 4 SILT 1011-10111 MED. COARSE GRAVEL, ROCKS t NO 5EDROCK WATER IV 80" Q, -, \3 RC 20" MOTTLING LEACN' ra 54 TOTAL DEPTH 0"-10" TOPSOIL 10"-29" SUENWIL 29"-54" MEiD, COARSE GRAVEL, ROCKS 5OULDER ON 50TTOM OF HOLE NO 15EDROCfK NO WATER NO MOTTLING ON NOVEM5ER 10, 2002 9:42 - 15.5" f 9:44 - 16.25" TH 135" i' DEPTH9 9:45 - 1125" 0"-16" DARK 5R SANDY LOAM TOPSOIL i9>"-45" DARK YELLOW 5ROWN SANDY LOAM WITH SILT AND STONES 9:52 - 15" SITE45"-62" GRAY 15ROWN, YELLOW 5ROWN SANDY LOAM WITH STONES 9:54 - 18.5" 62 "-91" COARSE SAND WITH GRAVEL AND 5TONE8 9:56 - 1815" NO 5EDROCK 9:55 - 19" NO WATER_,_. 10:00 - 19.25" 45" MOTTLING 10:02 - TH 10:04 - IS °15" 10:06 - 20" 120" TOTAL DEPTH 10:0$ - 20B" 0'-9" PARK 15ROUN SANDY LOAM TOPSOIL 10:10 - 20.15" 9"-45" FINE YELLOW 5ROWN SANDY LOAM 45"-(o6" GRAY, YELLOW 15ROWN, FINE SANDY LOAM WITH MOTTLE 10:12 - 21" LOCATION 66"-56" COARSE YELLOW BROWN SANDY GRAVEL 10:14 - 2125" 10:16 - 21,5" SCALE: 1"=1000' 56"-120" GRAY 4 5ROWN SAND 10:15 - 2115" NO BEDROCK 10:20 - 22" NO WATER 45" MOTTLING 30 MIN / 4.25 IN I MIN/IN P'Ei s :. RATE = 1 TO 10 MIN/IN TH 14G 111" TOTAL DEPTH LA Etngineers,) 0"-12" DARK 5ROWN FINE SANDY LOAM TOPSOIL CIVIL - STRUCTURAL - SURVEYING12"-44" YELLOW 15ROUrN FINE SANDY LOAM WITH STONES 44"-51" GRAY, GRAY 15ROWN SANDY LOAM Sl" -111" COARSE SAND 4 GRAVEL NO 15EDROCK 317 Main Street Norwich, Connecticu_ 105 WATER 860 886--1966 Fax 860 886 --91st 44„"MC7-iTLINC No. Date Revision Project No. T LOT 14 45 OLD COLCHESTER (ROAD EXT. CLA-333 `, 110” TOTAL DEPTH 0"-10" DARK 5ROLLN FINE , SANDY LOAM TOPSOIL Proj. Engin .• er 10"-49" YELLOW 15ROWN SANDY LOAM WITH C055LE5E.M.B. 49"-15" CRAY, YELLOW 5ROWN FINE SANDY LOAM WITH C055LE5 DEEORRRID"'GE 'to*' 3"Uwab" hw"u"I"v'vlSl'ou N Date: b 15"-110" COARSE YELLOW BROWN SAND NO BEDROCK MONTVILL FEB. 2005 NO WATER 40 Sheet No. 49" MOTTLING SCALE: I"=20' SEPTIC SYSTEM LAYOUT