Loading...
HomeMy WebLinkAboutSite Plan000 s 010 000 0.01 WELL RADIUS moi r i / \, • :. •• IL Ile LUF 04 UP tis l \ fit' `i,' - ,y / % \ -( FOMING U-16 UrL( .- UrSILTFENCE ur- X123 0120 PROPOSED i \ WELL WIF n N\\ 1 N NO FOOTING DRAIN t, OFOESED FOR GA _ 0116 _ -- WETLAN 5LIFFER— GAR. - t, 00 FF.=4-10;5 DECK SILT FENCE` 6" $OIL COVER MIN.) FINISH GRADE 2" 1211 NON -WOVEN FILTER FABRIC OVER STONE 4" PVC PERFORATED PLASTIC DISTRIBUTION PIPE CAaTM D 3033 ONE INCH CLEAN BROKEN STONE OR SCREENED GRAVEL iA.RT MOTTLING LINE 12" x 48" LEACHING TRENCH NOT TO SCALE f 3 ROWS OF &0 L1= `N\- f y ,\ ACHING NCHES \ PROPOSED ~,----- BEORDOi°r1 Y - R-411 THIOA SYSTEM DESIGN LOT 10 RESERVE SYSTEM: PERCOLATION RATE: 1 TOIO MIN./INCH 3 BEDROOM HOUSE EFFECTIVE LEACHING AREA REQUIRED 4958ETH100USEA12" DEEP x 48" WIDE TRENCH 10P0 , AL--BEPTIC TANS \ ___ EFFECTIVE LEACHING AREA OF TRENCH = 3 5F/LF LENGTH OF TRENCH REQUIRED -(4956F)/(3SF/LF)-165LF TEST HOLES SSOEDBYAMANDAACHMATOW4ROBERTRUSLOPE 13516 1, ! ON NOVEMBER 18, 2002 DEPTH TO RESTRICTIVE LAYER - 50" - i H.F.-14 F.F m 1.5 P.F.=1.0 MLSS REQUIRED - 21 LF H 010.$ USE THREE ROWS OF rod' AT V O.C. 118" TOTAL DEPT9 LEACHI AREA OVI ED =540QiF Iy SETBACK0"-12" DAW BROWN SANDY LOAM TOPSOIL1AtESYSTEM ,/ 12"-32" YELLOW BROWN SANDY LOAM PRIMARY SYSTEM: 32"-64" MOTTLE, YELLOW BROWN COARSE SAND USE SAME DESIGN AS RESERVE SYSTEM 64"-118" GRAY GRAY BROWN YELLOW BROWN SANDY LOAM19.-r NO BEDROCK l \\ NO WATER 04" MOTTLING TH10D TH 01\ yLQT 10 - PEP-,L!2LAIIQ --N TEE Q—ATA- 112" T -OCTAL DEPTH TOTAL DEPTH - 21" 0"-2" DARK BROWN SANDY LOAM TOFWIL SOAK AT 11:06 - 11:15 2"-&0" YELLOW BROWN SAND 4 COBBLES \ „ 80"-120" GRAY, YELLOW BROWN, BROWN GRAY 1:05 - 11.5 „ SANDY LOAM \ 1: OcJ - 14.5" 10' MIN NO BEDROCK NO WATER I:11 1:13 - lro.5" 10' 80" MOTTLING \-. , MIN 1:15 - 18" TH 010C r 121" TOTAL DEPTH 1:19 - 20" 0"-14" DARK BROWN FINE ,SANDY LOAM TOPSOIL 1:21 - 21 14"-84" YELLOW BROWN COARSE SAND WITH 1:23 - 22" COBBLES 4 STONES 8 MIN / 4 IN r 2 MIN/IN84 -96 DARK YELLOW BROWN COARSE SAND , COBBLES 4 STONES FERC. TE l TO 10 MIN S6"-12-111 COA1 E GRAY, GRAY BROWN, DARK YELLOW BROWN SAND NO BEDROCK' NO WATER 64" MOTTLING TW #10D 108" TOTAL DEPTH [ o . Date0"-9" DANK BROWN SANDY LOAM TOPSOIL 9"-80" YELLOW BROWN SAND 4 COBBLES WITH COBBLES 80"-108".GRAY, YELLOW BROWN, BROWN GRAY SANDY LOAM WITH COBBLES NOTE: NO BEDROCK NO WATER L THE HOUSE, SYSTEM AND WELL ARE TO BE 5TAKED 50" MOTTLING BY A LICENSED SURVEYOR PRIOR TO THE START LO Or CONSTRCUTION PERCOLATION RATE: 3 MIN/INCH co co 0 c M co LmL.A I as 1n . CD n A -k Engineers, Inc. CIVIL - STRUCTURAL - SURVEYING 317 Main Street Norwich, Connecticut Revision (860) 886--1.966 Fax (860) 886--9165 LOT 10 - 1627 OLD COLCHESTER Project No. CI. -3335 Proj. Engineer DEERRIDGE 8"Wob"'DIVIS10""E.M.B. Date: VILL FEB. 2005 Sheet No. SEPTIC SYSTEM LAYOUT