HomeMy WebLinkAboutSite PlanN/F
EST. OF JOHN JANii OWSKI
VOL. 509 PG. 493
MAP 9 - LOT 18)
vi
F.F.
EL.
S.F.
TYP,
IPIN
MON
x156.5
x152.4
154
150i.
FIRSTFLOOR
ELEVATION
SQUARE FEET
TYPICAL
IRON PIN
MONUMENT
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
EXISTING CONTOURS
PROPOSED CONTOURS
BUILDING SETBACK. LINE
TEST HOLE
1`C:rlViLi Y L' iJi\Vf.711 1"11'4L 1. A Vl ili YY tSL+.1.e
IN THIS AREA FOR SITE EINE
12" BROKEN STONE OR 1" SCREENED
GRAVEL, TYPICAL BOTH SIDES.
APPROVED AGGREGATE)
FINISHEDGRADE \
LIFTING HANDLES
48M
411
6" MIN SOIL COVER
KNOCKOUTS FORTRENCH INSTALLATION
END VIBW
12" HIGH GALLERY UNIT
NOiTO SCALE
FILTER. FABRIC
6.0" FLOW LINE
138--_"
4" PVC ELBOW
CUT FOR 4" OVERFLOW)
2.X2 5/816GA. WIRE MESH
11/211
FILTER
FABRIC
POST
COMPACTED
ANGLE 100 UP SLOPE
FOR STABILITY AND
SELF CLEANING
SILT FENCE
NOT TO SCALE
138
42
TEST HOLE DATA.
PER UNCAS HEALTH REPT.
10/11/07
TH#2A - 0"-10" TOPSOIL
I0"-36" BROWN SANDY LOAM
36"-90" SAND & GRAVEL
W.ATER@87", MOTTLING @2611 NO LEDGE
TH#2B - 0"-81¢ TOPSOIL
8"-39" BROWN SANDY LOAM
39"-94" SAND & GRAVEL
WATER@9011, MOTTLING @21 ", NO LEDGE
TH#2C - 0"-5" TOPSOIL
5"-31" BROWN SANDY LOAM
31 "-90" SAND & GRAVEL
WATER@81'", MOTTLING @19", NO LEDGE
TH#2D d 0"-9" TOPSOIL
9"-30" BROWN SANDY LOAM
30"-87" SAND & GRAVEL
WATER@80", MOTTLING @271f, NO :LEDGE
LIMITS OF SELECT FILL
88LF-12" CONCRETE GALLERIES
BOTTOM OF SYSTEM -144.30
INVERT AT GALLERIES - 144.80
TOP OF GALLERIES -145.30
EXIST. GRADE @ SYSTEM -144.5
SEE DETAIL)
144
146
150
152
156
158
160
162
Q FEY
9:-'
LOT 19B
3 BEDROOM HOUSE
SLOPE - 5.8%
PERC RATE - 8 MINANCH
RESTRICTIVELAYER - 21"
M,L.S.S. REQUIRED 42 x 1,5 x 1.2 =75.6
M.L.S.S. PROVIDED - 88'
3 BEDROOM HOUSE REQUIRES 495 S.F.
OF EFFECTIVELEACHING AREA
USE (11) - 8' LONG 12" DEEP CONCRETE GALLERIES
88x 5.9 = 519.2S.F.)
USE 1,250GAL. 2 COMPARTMENT SEPTIC TANK
W/ OUTLETFILTER DEVICE
NOTE: SAME SYSTEM FOR. RESERVE AREA
PERC TEST DATA
WI'INESSED BY ADVANCED SURVEYS
10/12/07
PERC 2
DEPTH -1t"
PRESOAK - 9:15 DRY AT 10:05
10:20 - 3" 10:45 -141/2"
10:25-8i" 10:50-151/41"
10:30 -11" 10:55 -16" DRY
10:35 -12 3/4"
10:40 -13 3/4"
PERC RATE m 8 MINUTES PER INCH
PERC 2A
DEPTH -15"'
PRESOAK. - 9:20 - DRY AT 10:10
M.25 - 4" 10:50-133/411
10:30-71/211 10:55 -141/4"
10:35 a 101/4" 11:00 -14 3/41' DRY
10:40 -121/4"
10:45 -13"
PERC RATE - 8.5 MINUTES PER INCA
CONSTRUCTION ENTRANCE
NOT TO SCALE
CAST
CONCRETE COVERS
PLAN
CAPACITIES A B C
1250 GAL 61" 51" 48-
1500 GAL 69" 59" 56"
4 x 412.6/12.6 GA. WIRE MESH
i- 6 x 6 6/6 GA. WIRE MESH
INLE` ' . -
11 3" VEVEIdN3
LIQUID LEVEL
CONTINUOUS HOT P
ai ASPHALT SEAL iv
SC. EM No
CROSS SECTION
1250/1500 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
snap is substantially correct as noted hereon.
0"
CT LIC. # 19789
live signature and. embossed (impression) type seal.
OUTLET
OUTLBT
FILTER
V DEVICE
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
AND SEPTIC SYSTEM.
2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED,
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6. THE CONTRACTOR. WILL BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION,
7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE,
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE NOTES
PER 1000 S.F.
STRAWMAY 70-90 tbs. FREE FROM. WEEDS
AND COARSE MATTER
WOOD CHIPS 185.2751bs. FREE OF COARSE MATTER.
AIR DIVED, TREAT WITH
PLANTING SCHEDULE: 12lbs NITROGEN / TON
SEEDING DATES:
APRIL 1 ... ---- JUNE 15
AUGUST 1------ SEPTEMBER 15
SEER MIXTURE:
45% RED FESCUE
45% KENTUCKY 13LUE GRASS
10% PERENNIAL RYE
1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN.
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND .BEYOND
TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL. SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A, THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 STEVE,
C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA
SIEVE SIZE: A #10 #40 #140 #200
PASSING: 100 70400 **10-50 0-20 0-5 WET` SIEVE
PASSING: 100 70.100 10-75 0-5 0-2.5 600 SIM
PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IFTHEHE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT.
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
r au aa>
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
i
I
CAST
CONCRETE COVERS
PLAN
CAPACITIES A B C
1250 GAL 61" 51" 48-
1500 GAL 69" 59" 56"
4 x 412.6/12.6 GA. WIRE MESH
i- 6 x 6 6/6 GA. WIRE MESH
INLE` ' . -
11 3" VEVEIdN3
LIQUID LEVEL
CONTINUOUS HOT P
ai ASPHALT SEAL iv
SC. EM No
CROSS SECTION
1250/1500 GALLON
2 COMPARTMENT
SEPTIC TANK
NOT TO SCALE
snap is substantially correct as noted hereon.
0"
CT LIC. # 19789
live signature and. embossed (impression) type seal.
OUTLET
OUTLBT
FILTER
V DEVICE
EROSION AND SEDIMENT CONTROL PLAN:
1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITE
TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE
AND SEPTIC SYSTEM.
2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED,
3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED
WITH HAYBALES OR SILT FENCE.
4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES.
5. PRIOR TO SITE DISTURBANCE, THE REPRESENTATIVE OF THE
TOWN OF MONTVILLE SHALL BE NOTIFIED WHEN SEDIMENT
CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION
CAN OCCUR.
6. THE CONTRACTOR. WILL BE RESPONSIBLE FOR THE INSTALLATION
AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL
MEASURES THROUGHOUT CONSTRUCTION,
7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH
WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE,
TEMPORARY VEGETATIVE COVER:
MULCHES APPLICATION RATE NOTES
PER 1000 S.F.
STRAWMAY 70-90 tbs. FREE FROM. WEEDS
AND COARSE MATTER
WOOD CHIPS 185.2751bs. FREE OF COARSE MATTER.
AIR DIVED, TREAT WITH
PLANTING SCHEDULE: 12lbs NITROGEN / TON
SEEDING DATES:
APRIL 1 ... ---- JUNE 15
AUGUST 1------ SEPTEMBER 15
SEER MIXTURE:
45% RED FESCUE
45% KENTUCKY 13LUE GRASS
10% PERENNIAL RYE
1. ALL CONSTRUCTION TO CONFORM TO STANDARDS OF THE CONNECTICUT
PUBLIC HEALTH CODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN.
2. THIS SYSTEM HAS NOT BEEN DESIGNED FOR THE USE OF LARGE
CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS. RESIDENTIAL
GARBAGE DISPOSALS ARE NOT ANTICIPATED FOR THIS DESIGN. IN THE
EVENT THAT SUCH AN INSTALLATION IS CONTEMPLATED FOR THE
PROPOSED HOUSE, A LARGER SEPTIC TANK AND INCREASED LEACHING
FIELD CAPACITY WILL BE REQUIRED.
LEACHING SYSTEM CONSTRUCTION NOTES:
1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIAL BETWEEN AND .BEYOND
TRENCHES TO BE PERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED
AND COMPACTED IN 6" LIFTS. SELECT FILL. SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS:
A, THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 3 INCHES.
B. THE FILL SHALL NOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVEL IS BETWEEN NO.4 & 3" SIEVES)
NO MORE THAN 45 PERCENT OF THE MATERIAL CAN BE RETAINED ON THE NO.4 STEVE,
C. THE FILL LESS THE GRAVEL SHALL MEET THE FOLLOWING GRADATION CRITERIA
SIEVE SIZE: A #10 #40 #140 #200
PASSING: 100 70400 **10-50 0-20 0-5 WET` SIEVE
PASSING: 100 70.100 10-75 0-5 0-2.5 600 SIM
PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATER THAN 75% IFTHEHE PERCENT
PASSING THE #100 SIEVE DOES NOT EXCEED 10% AND THE #200 SIEVE DOES NOT EXCEED 5%.
2. DOCUMENTATION OF TEST RESULTS ARE TO BE PROVIDED TO THE HEALTH DISTRICT.
3. FILL MATERIAL TO BE PLACED PRIOR TO TRENCH EXCAVATION. NO TRAFFIC OTHER THAN
TRACK -DRIVEN EQUIPMENTIS TO CROSS, DUMP, UNLOADOR OTHERWISE COMPACTTHE FILLAREA
AFTERTOPSOIL REMOVAL. FILLMATERIAL TO BE DUMPED ATTHEEDGE OFTHE STRIPPEDAREA AND
SPREAD AND COMPACTED WITH TRACK -DRIVEN VEHICLES. STOCKPILING IS TO TAKE PLACE UPGRADIENT OF
THE LEACHING AREA. THE AREA DOWN GRADIENT OF THE LEACHING AREA IS NOT TO BE DISTURBED.
SEPTIC SYSTEM CONSTRUCTION NOTES:
1. CONSTRUCTION SEQUENCE:
A. STRIP & STOCKPILETOPSOIL FROMLEACHING AREA.
B. PLACESELECT FILL TO WITHIN 6" OF FINISH GRADE.
C. EXCAVATE 6 WIDE TRENCHES AND PREPARE SURFACE.
D. PLACE GALLEY UNITS IN TRENCHAND FILL WITH STONE AS SHOWN.
E. PLACE AG WIDE STRIP OF NON -WOVEN FILTER FABRIC ON TOP OF
THE ENTIRE LENGTH OF THE SYSTEM AND BACKFILL WITH
NATIVE MATERIAL,
F. LOAM, FINE GRATE TOFINISHED GRADEAND SEED, PROTECTDISTURBED AREAS
WITH EROSIONCONTROLSUNTILFIRSTMOWING,
2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRA. HEAVY CAST IRON,
DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL.
3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR. 35 (4"PVC) OR APPROVED EQUAL UNLESS RIOTED.
4. SEPTIC TANK SHALL BE SET LEVEL ON A MDUMUM OF 6" OF PROCESSED GRAVEL OR. BROKEN
STONE ON COMPACTED SUBGRADE.
5, THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND
SEPTIC SYSTEM AS SHOWN ON THIS PLAN.
6. APPROVED STONE AGGREGATE FOR LEACHING GALLERIES SHALL BROKEN STONE, CRUSHED
STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FORNO.4
STONE:
SIEVE SIZE PERCENT PASSING (BY WEIGHT)
2 -INCH 100
1 -1/2 -INCH 90-100
1 -INCH 2O-55
3/4 -INCH 0-10
3/8 -INCH 0-5
7. THE BOTTOM OF THE LEACHING TRENCHES SHALL BE SET A MAXIMUM OF
3" INTO EXISTING GRADE.
8. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE
FIELD BY A LICENSED LAND SURVEYOR.
NOTES:
1. TOPOGRAPHIC INFORMATION ON TIES PLAN COMPLIES WITH T-2 MAPPING
STANDARDS. BASE FOR LEVELS: PERREFERENCE MAF.
2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY
A LAND SURVEYOR LICENSED IN THE STATE OF CONNECTICUT.
3. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R40.
4. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM
LOCATED ON ABUTTING PROPERTIES.
5. TOTAL AREA OF PROPERTY -153,839 S.F.+ (3.53 ACRES :t).
6. A BENCHMARK. IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE &
SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION.
7. THE PROPERTY IS SHOWN ON ASSESSORS MAP 9 - LOT 19B.
REFERENCE MAP:
SUBDIVISION PLAN PREPARED FOR RICHARD A. FRANKLIN, 289 OLD COLCHESTER
ROAD, MONTVILLE, CONNECTICUT, SCALE: 111=40', DATE,. 10/16/07, REVISED
TO 1/08, PREPARED BYADVANCED SURVEYS, LLC.