Loading...
HomeMy WebLinkAboutSite Plansol 138 \ LIMITS OF WETLANDS y PER SUBDIVISION MAP / g r WL#19 / J LIMITS DE WETLANDS REv Ew A PROPOSED RELOCATED I WELLWL#18 4 17 / --- 140 r` 0000 WOODLINE 140 1EX. WELL SEE NOTE #3) a ; FOOTING .1 DRAIN OUTLET INSTALL & MAINTAIN A CONTINUOUS.. ----142 LINE OF SILT FENCE (SEE DETAIL) N/F , 01 , EST. OF LUCILLE ZAGORSKI142-t._--'K#1D solo i ,.,^ VOL. 508 PG. 965 ; 144 ( MAP 9 -LOT 19-A) 1 , _ f LIMITS OF SELECT FILL #1C 0000 ®gVE r 0000 - .. Tki,5 ,,.. ,,, r 25' t 0000 MONO 88LF-12" CONCRETE GALLERIES +' ® 0000 BOTTOM OF SYSTEM -142.90 OPP,,,• 0000 -„ ,.• •' r ,,, - ' r # 146 INVERT AT GALLERIES - 143.40 WOO - 0000 ,,..-_- ' TOP OF GALLERIES -143.90 r ,,,, ...- , o BOX • __ >> __- __ ---- - --- EXIST. GRADE @ SYSTEM -143.4.•• I)\1V.-i43.S0 SEE DETAIL) , 1OLF "PVC t . a lg .., {SDR -35} DTIC 1144 --- ! 9 .. 1,250 GAL./2COMP. ..148 EX. 9E x144 •- i- TANK -:7 - ' t i t„ i 2$LF`=4 "T' C SEPTIC INV. IN -14415 ASTM D, 785) INV. OUT -143.90 l --.--- - LOT 19B LEGEND: PERC TEST DATA F.F. FIRST FLOOR EL. ELEVATION S.F. SQUARE FEET TYP, TYPICAL IPIN IRON PIN MON MONUMENT x156.5 EXISTING SPOTELEVATION x152.4 PROPOSED SKffELEVATION 150 -- -- EXISTING CONTOURS 150 - PROPOSED CONTOURS WATER@88", MOTTLING @3111, NO LEDGE BUILDING SETBACK LINE CROSS SECTION TEST HOLE TH#1C - 0"-10" TOPSOIL SEE DETAIL) 1000 j 15 152 r i B 1 4..- 146- __ -- ALKOUT 154 OPO> QM G - EX. WELL 156 3 BEDROOM _, l --- ( SEE NO #3) 14 3 _ p DENCE ` F _ S .0 ~ l r- --F L,-155.6 - 1PIN . y F 31.53` - Fi IPIN S 26°49' 1 J 150-//! r SET PO CH EX.QU5Ex .-- WELL / 7------#285 15 . ___--__-___. --- - - ------ - ---'. - OSE TOD 1 0 y-- PROPOSED 1 r4 -- WAVED bRIVEWAY i r g 160 50' PROPO EX. 61, t S F. 1 #2g9 OS PROPOSED UT LI j Mo DRIVE 17 160 .- 2755162 --_ CI:&P 2754 / oLCHsTER RAD OLD REMOVE BRUSH AND STONE WAIL IN THIS AREA FOR SITE LINE PROVIDE A NON -TRACKING CONSTRUCTION .ENTRANCE SEE DETAIL) 12" BROKEN STONE OR V SCREENED GRAVEL TYPICAL BOTH SIDES. APPROVED AGGREGATE) A8" FINISHED GRADE 6" MIN SOIL COVER LIFTING HANDLES 4" DIA.'HOLEZ(CUTFOR4' OVERFLOW) IFTIN r FILTER FABRIC 2X.2 5/816 EIA. WIREMESH l ll2"7n1 FILTER FABRIC TEST HOLE DATA PERC TEST DATA PER UNCAS HEALTH DEPT. WITNESSED BY ADVANCED SURVEYS10/11/07 10/12/07 TH#lA - 0"-13" TOPSOIL PERC 113"-58" BROWN SANDY LOAM 58"-96" SAND & GRAVEL DEPTH - 20" NO WATER, MOTTLING @2411, NO LEDGE PRESOAK - 8:15 - DRY AT 9:10 INLE " VENT------ . 9:15 - 7 1/4" 9:40.181,/2" TH#1B - 0"-4" TOPSOII. 9:20-101/211 9:45 -191/4" 9"-39" BROWN SANDY LOAM 9:25 -13" 9:50 - 20" DRY 39"-90" SAND &GRAVEL 9:30 -15 1/4" 9:35 -17" WATER@88", MOTTLING @3111, NO LEDGE U CROSS SECTION PERC RATE - 6 MINUTES PERINCH TH#1C - 0"-10" TOPSOIL 10"-36" BROWN SANDY LOAM 36"-92" SAND & GRAVEL PERC I WATER@80", MOTTLING @30", NO LEDGE DEPTH .22" PRESOAK - 8:15 - DRY AT 9:00 TH#1D-.0"-8" TOPSOIL V-36" BROWN SANDY LOAM 9:25 - 6" 9:55.20"1/2" 36"-91" SAND & GRAVEL 9:30 - 91/4" 10:00.21:1/4" WATER@7711, MOTTLING @26", NO LEDGE 9:35-121/2" 10:05.22" DRY 9:40 -15" 9:45 -171/4" PERC RATE - 6.7 MINUTES PER INCH MLSS DATA LOT 19 3 BEDROOMROUSE SLOPE - 5.2% PERC RATE - 6 MINANCH RESTRICTIVE LAYER - 24" M.L.S.S. REQUIRED - 34 x 1.5 x 1.2 - 61.2' M.L.S.S. PROVIDED - 88' 3 BEDROOM HOUSE REQUIRES 495 S.F. OF EFFECTIVE LEACHING AREA USE (11) - T LONG 12" DEEP CONCRETE GALLERIES 88x5.9 = 519.2 S.F.) USE 1,250GAL. 2 COMPARTMENT SEPTIC TANK W/ OUTLET FILTERDEVICE NOTE: SAME SYSTEM FOR RESERVE AREA ANGLE 100 UP SLOPE 6.6" FLAW LINE POST FORSTABILITY AND SELF CLEANING 12" TYp. KNOCKOUTS FORTRENCH INSTALLATION _1______ r ' COMPACTED \ \ K I BACKFILL 2" f - END VIEW SILT FENCE 12" HIGH GALLBRY UNIT STANDARD. D -BOX W/ELBOW h`U•, TO SCALE xoScrTou.zi NOT TO SCALE CONSTRUCTION ENTRANCE NOTTO SCALE pUT INLET AND CAST CONCRETE COVERS PLAN CAPACITIES A B C 1250 GAL 61" 51" 48- 1500 GAL 69" 59" 56" 4 x 412.6/12.6 GA. WIRE MESH 171/21, 6 x 6 6/6 GA. WIRE MESH INLE " VENT------ . OUTLET LIQUID LEVEL- d CONTINUOUS HOT P OUTLET as A rHALT SEAL FILTER DEVICE SCHED. #40 U CROSS SECTION 1254/1500 GALLON 2 COMPARTMENT SEPTIC TANK NOT TO SCALE CONNe- -le FIG o N e 4 s map is substantially correct as noted hereon, V _ ' L r'+ CT LIC. # 19789 0Wt. eq. Certift 7j"""1 Ac t'`1Vithaut live signature and embossed (impression) type seal. vk EROSION AND SEDIMENT CONTROL PLAN: 1. CLEARING, GRUBBING, AND GRADING OF THE PROPOSED SITU TO BE LIMITED TO AREAS ADJACENT TO THE PROPOSED HOUSE AND SEPTIC SYSTEM. 2. DISTURBED AREAS TO BE LOAMED, SEEDED, AND MULCHED. 3. ALL TOPSOIL TO BE STOCKPILED ON SITE AND PROTECTED WITH HAYBALES OR SILT FENCE. - 4. ALL CUT AND FILL SLOPES ARE NOT TO EXCEED 3:1 SLOPES. 5. PRIORTO SITE DISTURBANCE, THE REPRESENTATIVE OF THE TOWN OF MONTVILLE SHALL BENOTIFIEDWHEN SEDIMENT CONTROL MEASURES ARE IN PLACE SO THAT THE INSPECTION CAN OCCUR. 6. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL REQUIRED SEDIMENT CONTROL MEASURES THROUGHOUT CONSTRUCTION. 7. DUST CONTROL WILL BE ACCOMPLISHED BY SPRAYING WITH WATER, AND IF NECESSARY THE APPLICATION OF CALCIUM CHLORIDE. TEMPORARY VEGETATIVE COVER: MULCHES APPLICATION RATE NOTES PER 1000 S.F. STRAWdIAY 70-90 N. FREE FROMWEEDS AND COARSE MATTER WOOD CHIPS 185.275 lbs. FREE OF COARSE MATTER AIRDRIED, TREAT WITH PLANTING SCHEDULE: 121bs NITROGEN / TON SEEDING DATES: APRIL 1------- JUNE 15 AUGUST 1----- SEPTEMBER 15 SEED MIXTURE: 45% RED FESCUE 45% KENTUCKY BLUE GRASS 10% PERENNIAL RYE DESIGN NOTES; 1. ALL CONSTRUCTIONTOCONFORM TO STANDARDS OF THE CONNECTICUT PUBLIC HEALTHCODE AND TO THE SATISFACTION OF THE TOWN SANATARIAN. 2. THIS SYSTEM HAS NOT BEEN DESIGNED FORTHE USE OF LARGE CAPACITY (+100 GALLONS), DISCHARGE TYPE BATHTUBS, RESIDENTIAL GARBAGEDISPOSALS ARENOT ANTICIPATED FOR THIS DESIGN. INTHE EVENT THATSUCH AN INSTALLATION IS CON`TWLATED FOR THE PROPOSED HOUSE, ALARGER SEPTIC TANKAND INCREASED LEACHING FIELD CAPACITY WILL BE REQUIRED. LEACHING SYSTEM CONSTRUCTION NATES: 1. TOPSOIL TO BE STRIPPED OFF PRIOR TO FILLING. FILL MATERIALBETWEENAND BEYOND TRENCHES TO BEPERVIOUS, GOOD QUALITY AND CLEAN MEDIUM SAND (SELECT FILL) PLACED ANDCOMPACTEDIN 6" LIFTS. SELECT FILL SHALL MEET THE FOLLOWINGMINIMUM REQUIREMENTS: A. THEFILL SHALLNOTCONTAIN ANY MATIOtIAL LARGERTHAN 3 INCHES. B. THE FILL SHALLNOT CONTAIN MORE THAN 45 PERCENT GRAVEL (GRAVELIS BETWEENNO.4 & 3' SIEVES) NOMORE THAN 45 PERCENT OFTHEMATERIAL CAN BE RETAINEDON THE NO.4SIEVE. C. THE FILLLESSTHE GRAVEL SHALL MEET THE FOLLOWINGGRADATIONCRITERIA: SIEVE SIZE: #4 #10 #40 #100 #12200 PASSING: 100 70-100 "10-50 0-20 0.5 WET SIEVE PASSING: 100 70-100 10-75 0-5 0-2.5 DRY SIEVE PERCENT PASSING THE #40 SIEVE CAN BE INCREASED TO NO GREATERTHAN 75% IFTHE PERCENT PASSING THE # 100 SIEVE DOES NOT EXCEED 10% ANDTHE #200 SIEVE DOES NOTEXCEED 5'/s. 2. DOCUMENTATION OF TESTRESULTS ARE TO BEPROVIDED TOTHEHEALTH DISTRICT. 3.- FILL MATERIAL TO BE PLACEDPRIORTO TRENCH EXCAVATION. NO TRAFFICOTHER THAN TRACK -DRIVEN EQUIPMENT IS TO CROSS, DUMP, UNLOAD OR OTHERWISE COMPACT THE FILLAREA AFTERTOPSOIL REMOVAL. FILL MATERIAL TO BE DUMPEDATTHEEDGE OF THE STRIPPED AREA AND SPREAD ANDCOMPACTED WITH TRACK-DRPIEN VEHICLES. STOCKPILM IS TO TAKE PLACE UPGRADIENT OF THE LEACHING AREA. THE AREA DOWN GRADIENTOF THELEACHING AREAIS NOTTOBE DISTURBED. SEPTIC SYST`EM CONSTRUCTIONNOTES: - 1. CONSTRUCTION SEQUENCE: A.. STRIP & STOCKPILE TOPSOIL FROM LEACHING AREA. B. PLACE SELECT FILL TO W UEN 6" OF FINISHGRADE. C, EXCAVATE 6' WIDE TRENCHES AND PREPARE SURFACE. D. PLACE GALLEY UNITS IN TRENCH AND FILL WITH STONE AS SHOWN. E. PLACE A 6WIDE STRIP OF NON -WOVEN FILTER FABRIC ON TOP OF THE ENTIRE LENGTH OF THE SYSTEM AND BACKFILL WITH NATIVE MATERIAL. F. LOAM, FINE GRADETOFINISHED GRADEAND SEED. PROTECT DISTURBEDAREAS WITH EROSION CONTROLS UNTIL FIRST MOWING. 2. THE PIPE BETWEEN THE HOUSE AND SEPTIC TANK SHALL BE 4 IN. EXTRAHEAVY CAST IRON, DUCTILE IRON OR EXTRA STRENGTH PVC ASTM D1785 SCHD 40 OR APPROVED EQUAL. 3. ALL DISTRIBUTION PIPE IS TO BE ASTM D3034 SDR 35 (4"PVC) OR APPROVED EQUAL UNLESS NOTED. 4. SEPTIC TANK SHALL BE SETLEVEL ON A :MINIMUM OF 6" OF PROCESSED GRAVEL OR BROKEN STONE ON COMPACTED SUBGRADE. 5. THERE ARE NO APPARENT WELLS OR SEPTIC FIELDS WITHIN 75' OF THE PROPOSED WELL AND SEPTIC SYSTEM AS SHOWN ON THIS PLAN. 6. APPROVED STONE AGGREGATE FOR LEACHING GALLERIES SHALL BROKEN STONE, CRUSHED STONE, OR SCREENED GRAVEL MEETING CT DOT FROM 814A SPECIFICATION FOR M.01.01 FOR NO.4 STONE: SIEVE SIZE PERCENT PASSING (BY WEIGHT) 2 -INCH 140 1 -1/2 -INCH 90-100 1 -INCH 2O-55 3/4 -INCH 0-10 3/8-I1NCH 0-5 7. THE BOTTOM OF THE LEACHING TRENCHES SHALL BE SET A MAXIMUM OF 6" INTO EXISTING GRADE. 8. THE LOCATION AND ELEVATION OF THE PROPOSED SEPTIC SYSTEM SHALL BE STAKED IN THE FIELD BY A LICENSED LAND SURVEYOR. NOTES: 1. TOPOGRAPHIC INFORM-4TION ON THIS PLAN COMPLIES WITH T-2 MAPPING STANDARDS. BASE FORLEVELS: PER REFERENCE MAP, 2. PROPOSED HOUSE AND SEPTIC SYSTEM TO BE STAKED IN THE FIELD BY A LAND SURVEYOR LICENSED INTHE STATE OF CONNECTICUT, 3. EXISTING WELLS TO BE ABANDONED BY A LICENSED WELL DRILLER. 4. PROPERTY IS LOCATED IN THE TOWN OF MONTVILLE ZONING DISTRICT R40. s 5. THERE ARE NO WELLS LOCATED WITHIN 75' OF THE PROPOSED SEPTIC SYSTEM LOCATED ON ABUTTING PROPERTIES. 6. TOTAL AREA OF PROPERTY - 60,233 S.F.E (1.38 ACRES f). 7. A BENCHMARK IS TO BE PLACED WITHIN 50' OF THE PROPOSED HOUSE & SEPTIC SYSTEM AT THE TIME OF CONSTRUCTION. 8. THE PROPERTY IS SHOWN ON ASSESSORS MAP 9 - LOT 19. REFERENCE MAP: SUBDIVISION PLAN PREPARED FOR RICHARD A. FRANKLIN, 289 OLD COLCHESTER ROAD, MONTVILLE, CONNECTICUT, SCALE: 1"=40', DATE: 10/16/07, REVISED TO 1/08, PREPARED BY ADVANCED SURVEYS, LLC. PROJECT NO. 08-011 SEPTIC SYSTEM DESIGN PLAN DRAWN BY: KAR PREPARED FOR DATE: 1/22/08 SCALE: 111-201 RICHARD A. FRANKLIN SHEET I OF i REVISIONS #289 OLD COLCHESTER ROAD MOri MLLE, CONNECTICUT LOT. # 19 ADVANCED SURVEYS, LLC. N 20 to 0 20 162 River Road, Preston CT. 06365 W E Phone & Fax (860) 859-1280 GRAPHIC SCALE IN FEET S