HomeMy WebLinkAboutSite PlanI
6>0
v
Lot Area = 108,364 5F
or 2.48 Acr-es
\
o\0)
\;
ExiStng Dug Well 0
This dug well to be filled in \, \ \ �� 0)
conformance with current
Footing Drain Discharge
CT Health Code Regulations El 123,0 �` \
x,
\
1.
Test Pit
\ \
\ \ \
es
PDX
\ N ran �i
Test PI
w Proposed 3 BR
f \ Frame DwellingInv@ 13.80 �i Inv@ 1 D.
Fin. Floor 136.50 1 OO Gallon` eptic ank overflow st It
� /� In @J 31 .0 ` �� �
'
Inv@ 3.25 Ov rflow �� STP#2
U Inv 132. 0
f \ 2G LF 4- PVC \ Inv@ 133:0
ASTM D 1765
cn 5ch 40 @ 1/4" LIF \
Burie Propane \�
Tank
/ O t
Ft
14 0
AV
\i \
\ 1110 ;;
\� \ 0
0)
14
Inspection Opening
Minimum 17" (optional) Minimum 17"
Diameter Manhole ' Diameter Manhole
5" min. 8" min.
—�-- Outlet
15s -I' G" 3" min. i O" mm. Outlet Filter
—�-- Device
Liquid Depth Mid -De th
213 Required q pt Connection
Capacity
1/3 Required
Capacity
AL
Length Not Greater Than
4 T1me5 Width or Depth
Section Through
Typical Septic Tank
Not to Scale
THIS MAP AND SURVEY a n d DRAWN BY: D.A.K. DATE: June 9, 2004
x A-2, a Sand 5 u rve CONFORMS Tp A CLA55 A-2 M� S
' SURVEY AND 15 SUBSTANTIALLY ,
o I Inch 2a feet L
CORRECT TO E F MY .
En jineerin�j Surve inKNOWLEDG BEU ,kI
i
( 1 ; . :r I O 20 40 60 80`L U' 2 7-11-04 Re railed
t ,
G27 Norwich Koad.(Kte 82)I 6-26-04 Per Uncas Health District
hp &up�ia4 Graphic Scale ph NO. DATE DESORIPTI4N
Oakdale, CT OG370 g
9- 5
REVISIONS
` David A. 1"vn rofess�onal Engineer land Surveyor �.,�'
--1.-'---"(NOT V WITt10UT LIVE STAMP 4 IGNATURE)
DK
DK
BY
Nates.
I .This property 15 located In thr K-80 zone and is a pre-existing, non conforming parcel.
i Criteria Required Provided
1 i
I Area (a5 rear lot) 120,000 SF 108,3G4 5F
Frontage 180 Ft 29.81 Ft
Front Yard 50 Ft 50 Ft
l 51de Yard 20 Ft 20 Ft
I Rear Yard 50 Ft 50 Ft
A 3 bedroom 5ingle family house 15 proposed for this 51te. The percolation rate 15 20
minute5 per Inch, the hydraulic gradient 15 10.7% and a critical layer (mottling) eX15t5 at
1 32 Inches. Based on the foregoing the ML55 15 45 Ft. Th15 dwellincj requires G75 LF of
j5eptic d15p05al area. The de5lgn provlde5 225 Lr of 12" X 48" trenches arrayed -a5 three
75 rt rows to provide 3X75X3 5F or G75 5F of area.
Test hole Data by the Unca5 Health D15trict. David Coughlin, Sanitarian
TH #I
011-911 Topsoil
9"-32" Brown Sandy Loam
32"-9G" Grey Medium Compact Sandy Till
Water@54", Mottling @32"
. TH#2
1011._711 Topsoil
7"-39" Brown Sandy Loam
39"- 102Grey Medium Compact Sandy Till
water@G4", Mottlln9 @G4"
Th #3�`
f 0" 10"Topsoli
9"-24"
Brown Sandy Loam
24"-47" Grey Sand
47"-102" Dark Grey Sandy TIII
Water@7I
TH#4
-z>" t vpSUl l
8"-2911 Brown Sandy Loam
29"-45" Grey Sand
45"-9G" Grey Medium Compact Sandy Till
Water@G2", Mottling@45"
Percolation Test Ke5ult5 (by Unca5 Health Dept.)
Time Depth
1:15 3.511
I
1:30 5.511
1:45 711
2:00 8.25"
2.15 9"
Depth 20, Presoak 2.5 HI -5, Perc Rate 20min/Inch
241 F MassG�`q Rr1`
Plan of Development
Pietri35 Property
24 I BE3 Ma55apeaq Road.
Montville, Connecticut
511EET NUMBER
1
OF
1