Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
26000 -Gas generators-Azt
MAGGIORE CONSTRUCTION CORP. 13 Wheeling Avenue, Woburn, MA 01801 Phone 781.935.6100 FAX 781.933.8044 SUBMITTAL ACTION SHEET Oxoboxo Lofts 40 Pink Row Uncasville, CT General Contractor:Architect: Maggiore Construction Corp.Paul B Bailey Architects 13 Wheeling Ave.110 Audubon Street Woburn, MA 01801 New Haven, CT 06510 Job No.: 1214 Job No.: 16-063 Prepared By:Maggiore Construction Corp. Form of Submittal: Samples Cut Sheets Schedule Shop Drawings Other Description:Generator G-1 & G-2 ATS 100 KW & 130 KW Manufacturer:Natural Gas Generator by Generac Other/Notes: Received By MCC:10/25/2019 Received By Owner: Reviewed:Comments: Approved Approved as Noted Rejected Revise and Re-submit Compliance Equal Submitted For Approval By: Gifford Perry - Senior Project Manager Approved By: Date:10/28/2019 Date: Horton Electrical Services,LLC Canton Business Park 97 River Road Canton, Connecticut 06019 (860)693.6388 (860)693.6517 FAXLicense # CT E-192436 Date:10/17/2019 Job:19-01-021 OXOBOXO Phase 1 Letter of Transmittal Transmittal #:2To:Gifford Perry Subject:Submittal-Generators & ATS Samples Change order Shop drawings Under separate cover via the following items:AttachedWE ARE SENDING YOU Submittal Prints Plans Copy of letter Spec. Section DescriptionNo.DateCopiesDocument Type 1 10/17/19 Generators & AT-1 Re 100kw Generator, 130kW Genertor & ATSSubmittal Other PRINTS RETURNED AFTER LOAN TO USFOR BIDS DUE For review and comment Return ___ corrected printsReturned for corrections Submit ___ copies for distributionApproved as noted For approval Resubmit ___ copies for approvalApproved as submitted THESE ARE TRANSMITTED as checked below: Remarks: For your use As requested Copy To:Gerry Campion (Horton Electrical) Signature:From:Marilyn Horton (Horton Electrical Services, LL) If enclosures are not as noted, kindly notify us at once. Page 1 of 1 OXOBOXO LOFTS 42 Pink Row Uncasville, CT 10-17-19 GENERAL CONTRACTOR: Maggiore Invest Design Build 13 Wheeling Avenue Woburn, MA 01801 ELECTRICAL CONTRACTOR: Horton Electrical Services 97 River Road Canton, CT 06019 860‐693‐6388 Generators & ATS CIVIL ENGINEER: BSC Group 300 Winding Brook Drive Glastonbury, CT 06033 STRUCTURAL ENGINEER: Morrissey Engineering, LLC 58 Essex Street Deep River, CT. 06417 ARCHITECT: Paul B. Bailey Architect, LLC. 110 Audubon Street New Haven, CT 06510 MECHANICAL/ELECTRICAL ENGINEER: Aztech Engineer, Inc. 901 Wethersfield Avenue Hartford, CT 06114 Engineering Submittal Package OXOBOXO Lofts Uncasville, CT 100kW Natural Gas Generator 400A Automatic Transfer Switch Presented to: Horton Electrical Services, LLC 97 River Rd. Canton, CT 06019 860-693-6388 www.hortonelectric.com Prepared by: Huntington Power 230 Long Hill Cross Rd Shelton, CT 06484 203-929-3203 www.huntingtonpower.com 230 Long Hill Cross Rd Shelton, CT 06484 203-929-3203 ~ 203 929 0713 (f) 34 E. Dudley Town Rd, Bloomfield, CT 06002 860-289-8790 ~ 860-282-0472 (f) 68 Enter Lane Islandia, NY 11749 631-563-4943 ~ 631-563-6057 (f) BILL OF MATERIAL SPECIFICATION SHEET 0K4291 SG100 9.0L CONTROL PANEL AND OPTIONS 0172110SBY SPEC SHEET H-100 CONTROL PANEL 0604160SSD 21-LIGHT/RELAY PANEL DATA ALTERNATOR AND OPTIONS 0182610SSD ALT DATA SHT 0187980SBY GENPROTECT DATA SHEET UNIT OPTIONS 0161970SBY BATTERY INDEX 0163180SBY SERIES 2000 ENCL SPEC 0180230SBY SPEC SHEET RHINO COAT 0189370SSD EATON CB TABLE THERM/MAG 0191900SBY 2.5A & 10A BATT CHRGR H&G 0192390SSD EATON CB LUG DATA 0196730SSD SOUND DATA SG100 0604400SSD ELEC GOV GAS ENG SUB DATA 084918Q_SBM BLOCK HTR 1500W 120V 084918Q SBM 0L6262 E STOP BRK GLS H PNL SUBM INSTALLATION DRAWINGS 0K0383B INSTALL L1A ENC G9.0L 80-100KW 10000002132 GAS SUPPLY CHECKLIST SUBMITTAL DOC 10000013539 INSTALL OPEN SET G9.0L G26 CAT 10000046207 GAS SYSTEM DESIGN GUIDELINES GENSET ELECTRICAL DRAWINGS 0H9856 WD G9.0L G18 H-PANEL 0H9857 SD G9.0L G18 H-PANEL SYSTEM INTERCONNECT DRAWINGS 0191120SSD INTERCONNECT DIAG H PANEL CERTIFICATIONS 0184520SSD QUALITY CERTIFICATION DOC 0K3486 STANDARD 2B WARRANTY 0K8347 ISO CERTIFICATE 9001 : 20 EMSNWRNTY001 EPA WARRANTY EMSN STATEMENT AUTOMATIC TRANSFER SWITCH 978732 ASCO GROUP G 260-400A ATS OUTLINE NEMA 1 978745 ASCO GROUP G 260-400A 3PH WIRING DIAGRAM Bill of Material Quantity 1 - Generac Industrial gas engine-generator consisting of the following features and accessories: 100 kW Rating, wired for 120/208 VAC three phase, 60 Hz Natural Gas fuel fuel system Stationary Emergency-Standby rated Level 1 Acoustic Enclosure, Steel Critical Muffler – Inside Enclosure 400A Circuit Breaker UL2200 Listed EPA Certified H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range -40 to 70 degrees C o Digital Microprocessor: Two 4-line x 20 displays, full system status 3 Phase sensing, +/-0.25% digital voltage regulation RS232, RS485 and Canbus remote ports Waterproof connections All engine sensors are 4-20ma for minimal interference Programmable I/O Built-in PLC for special applications o Engine function monitoring and control: Full range standby operation; programmable auto crank, E-Stop, Auto-Off-Manual switch Isochronous Governor, +/-0.25% frequency regulation Full system status on all AC output and engine function parameters Service reminders, trending, fault history (alarm log) I2T function for full generator protection Selectable low-speed exercise o 2-wire start controls for any 2-wire transfer switch 21 Light Remote Annunciator Battery Charger, 10 Amp, NFPA 110 compliant, installed 110 AH, 1100 CCA Group 8D Batteries, with rack, installed Coolant Heater, 1500W, 120VAC Std set of 3 Manuals 120V GFCI and 240V Outlet 2-Year Warranty Onsite Startup & Testing Quantity 1 - Automatic Transfer Switch consisting of the following features and accessories: Open Transition 400 Amp, 3 Pole, Solid Neutral 120/208 VAC three phase, 4 wire UL1008 Listed NEMA 1 Enclosure SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET1 of 6 DEMAND RESPONSE READY Image used for illustration purposes only Standby Power Rating 100 kW, 125 kVA, 60 Hz Prime Power Rating 90 kW, 113 kVA, 60 Hz Powering Ahead Generac ensures superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up — all at our facilities throughout Wisconsin. Applying natural gas and LP-fueled engines to generators requires advanced engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single- source responsibility. Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas. Codes and Standards Generac products are designed to the following standards: UL2200, UL508, UL489 CSA 22.2 BS5514 and DIN 6271 SAE J1349 NFPA 37, 70, 99, 110 NEC700, 701, 702, 708 ISO 3046, 7637, 8528, 9001 NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012) TM ® ® *Assembled in the USA using domestic and foreign parts *EPA Certified Prime ratings are not available in the US or its Territories SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET2 of 6 DEMAND RESPONSE READY CONTROL SYSTEM Digital H Control Panel- Dual 4x20 Display Program Functions •Programmable Crank Limiter •7-Day Programmable Exerciser •Special Applications Programmable Logic Controller •RS-232/485 Communications •3-Phase Sensing Digital Voltage Regulator •2-Wire Start Capability •Date/Time Fault History (Event Log) •Isochronous Governor Control •Waterproof/Sealed Connectors •Audible Alarms and Shutdowns •Not in Auto (Flashing Light) •Auto/Off/Manual Switch •E-Stop (Red Mushroom-Type) •NFPA110 Level I and II (Programmable) •Customizable Alarms, Warnings, and Events •Modbus® Protocol •Predictive Maintenance Algorithm •Sealed Boards •Password Parameter Adjustment Protection •Single Point Ground •16 Channel Remote Trending •0.2 msec High Speed Remote Trending •Alarm Information Automatically Annunciated on the Display Full System Status Display •Power Output (kW) •Power Factor •kW Hours, Total, and Last Run •Real/Reactive/Apparent Power •All Phase AC Voltage •All Phase Currents •Oil Pressure •Coolant Temperature •Coolant Level •Engine Speed •Battery Voltage •Frequency Alarms and Warnings •Oil Pressure •Coolant Temperature •Coolant Level •Low Fuel Pressure Alarm •Engine Overspeed •Battery Voltage •Alarms and Warnings Time and Date Stamped •Snap Shots of Key Operation Parameters During Alarms and Warnings •Alarms and Warnings Spelled Out (No Alarm Codes) ENGINE SYSTEM •Oil Drain Extension •Air Cleaner •Fan Guard •Stainless Steel Flexible Exhaust Connection •Factory Filled Oil and Coolant •Radiator Duct Adapter (Open Set Only) •Critical Exhaust Silencer Fuel System •Fuel Line - NPT Connection •Primary and Secondary Fuel Shutoff Cooling System •Closed Coolant Recovery System •UV/Ozone Resistant Hoses •Factory-Installed Radiator •50/50 Ethylene Glycol Antifreeze •Radiator Drain Extension Electrical System •Battery Charging Alternator •Battery Cables •Battery Tray •Rubber-Booted Engine Electrical Connections •Solenoid Activated Starter Motor ALTERNATOR SYSTEM •GENprotect™ •Class H Insulation Material •2/3 Pitch •Skewed Stator •Brushless Excitation •Sealed Bearing •Amortisseur Winding •Full Load Capacity Alternator GENERATOR SET •Internal Genset Vibration Isolation •Separation of Circuits - High/Low Voltage •Separation of Circuits - Multiple Breakers •Wrapped Exhaust Piping •Standard Factory Testing •2 Year Limited Warranty (Standby Rated Units) •1 Year Warranty (Prime Rated Units) •Silencer Mounted in the Discharge Hood (Enclosed Only) ENCLOSURE (If Selected) •Rust-Proof Fasteners with Nylon Washers to Protect Finish •High Performance Sound-Absorbing Material (Sound Attenuation Enclosures) •Gasketed Doors •Stamped Air-Intake Louvers •Upward Facing Discharge Hoods (Radiator and Exhaust) •Stainless Steel Lift Off Door Hinges •Stainless Steel Lockable Handles •RhinoCoat™ - Textured Polyester Powder Coat Paint STANDARD FEATURES SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET3 of 6 DEMAND RESPONSE READY *Consult factory for availability CONFIGURABLE OPTIONS ENGINE SYSTEM ż Engine Block Heater ż Oil Heater ż Air Filter Restriction Indicator ż Stone Guard (Open Set Only) ELECTRICAL SYSTEM ż 2.5A UL Battery Charger ż 10A UL Battery Charger ż Battery Warmer ALTERNATOR SYSTEM ż Alternator Upsizing ż Anti-Condensation Heater ż Tropical Coating ż Permanent Magnet Excitation CIRCUIT BREAKER OPTIONS ż Main Line Circuit Breaker ż 2nd Main Line Circuit Breaker ż Shunt Trip and Auxiliary Contact ż Electronic Trip Breakers GENERATOR SET ż GenLink® Communications Software (English Only) ż Extended Factory Testing (3-Phase Only) ż 8 Position Load Center ż IBC Seismic Certification ENCLOSURE ż Standard Enclosure ż Level 1 Sound Attenuation ż Level 2 Sound Attenuation ż Level 2 Sound Attenuation with Motorized Dampers ż Steel Enclosure ż Aluminum Enclosure ż AC/DC Enclosure Lighting Kit ż Door Alarm Switch CONTROL SYSTEM ż NFPA 110 Compliant 21-Light Remote Annunciator ż Remote Relay Assembly (8 or 16) ż Oil Temperature Indicator with Alarm ż Remote E-Stop (Break Glass-Type, Surface Mount) ż Remote E-Stop (Red Mushroom-Type, Surface Mount) ż Remote E-Stop (Red Mushroom-Type, Flush Mount) ż Remote Communication - Modem ż 10A Run Relay ż Ground Fault Indication and Protection Functions ż Damper Kit Auxiliary Contacts WARRANTY (Standby Gensets Only) ż 2 Year 6WDQGDUG Limited Warranty ż 5 Year Limited Warranty ż 5 Year Extended Limited Warranty ż 7 Year Extended Limited Warranty ż 10 Year Extended Limited Warranty ENGINEERED OPTIONS ENGINE SYSTEM ż Coolant Heater Ball Valves ż Fluid Containment Pan ALTERNATOR SYSTEM ż 3rd Breaker System CONTROL SYSTEM ż Spare Inputs (x4) / Outputs (x4) ż Battery Disconnect Switch GENERATOR SET ż Special Testing ż Battery Box ENCLOSURE ż Enclosure Ambient Heaters ż Up to 200 MPH Wind Load Rating* Engine Block Heater 10A UL Battery Charger Tropical Coating Permanent Magnet Excitation Main Line Circuit Breaker Extended Factory Testing (3-Phase Only) Level 1 Sound Attenuation Steel Enclosure NFPA 110 Compliant 21-Light Remote Annunciator Remote Relay Assembly (8 or 16) Remote E-Stop (Break Glass-Type, Surface Mount) 2 Year 6WDQGDUG Limited Warranty SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET4 of 6 DEMAND RESPONSE READY General Make Generac Cylinder # 8 Type V Displacement - Cu In (L) 540 (8.9) Bore - in (mm) 4.49 (114.23) Stroke - in (mm) 4.25 (107.15) Compression Ratio 10.5:1 - G18 9.9:1 - G26 Intake Air Method Naturally Aspirated Number of Main Bearings 5 Connecting Rods Forged Steel Cylinder Head Cast Iron Cylinder Liners No Ignition High Energy Piston Type Aluminum Alloy Crankshaft Type Forged Steel Lifter Type Hydraulic Roller Intake Valve Material Steel Alloy Exhaust Valve Material Stainless Steel Hardened Valve Seats Yes Engine Governing Governor Electronic Frequency Regulation (Steady State) ±0.25% Lubrication System Oil Pump Type Gear Oil Filter Type Full-Flow Spin-On Cartridge Crankcase Capacity - qts (L) 8.0 (8.5) - G18 10.5 (9.9) w/ Filter - G26 Cooling System Cooling System Type Pressurized Closed Recovery Fan Type Pusher Fan Speed (rpm) 2,330 - G18 2,385 - G26 Fan Diameter - in (mm) 22 (558) Fuel System Fuel Type Natural Gas, Propane Vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure in H2O 11 - 14 Optional Operating Fuel Pressure in H2O 7 - 11 Engine Electrical System System Voltage 12 VDC Battery Charger Alternator Standard Battery Size See Battery Index 10000016949 Battery Voltage 12 VDC Ground Polarity Negative APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS ALTERNATOR SPECIFICATIONS Standard Model Generac 390 mm Poles 4 Field Type Revolving Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% (3-Phase) Telephone Interference Factor (TIF) <50 Standard Excitation Synchronous Brushless Bearings Sealed Ball Coupling Direct Drive Prototype Short Circuit Test Yes Voltage Regulator Type Full Digital Number of Sensed Phases All Regulation Accuracy (Steady State) ±0.5% NOTE: G18 is all engines manufactured before October 12, 2017. G26 is all engines manufactured after October 12, 2017. SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET5 of 6 DEMAND RESPONSE READY ** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes. Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards. Standby - See Bulletin 0187500SSB Demand Response - See Bulletin 10000018250. POWER RATINGS - NATURAL GAS/PROPANE VAPOR Standby/Demand Response Single-Phase 120/240 VAC @1.0pf 100 kW Amps: 417 Three-Phase 120/208 VAC @0.8pf 100 kW Amps: 347 Three-Phase 120/240 VAC @0.8pf 100 kW Amps: 301 Three-Phase 277/480 VAC @0.8pf 100 kW Amps: 150 Three-Phase 346/600 VAC @0.8pf 100 kW Amps: 120 STARTING CAPABILITIES (sKVA) sKVA vs. Voltage Dip 277/480 VAC 208/240 VAC Alternator kW 10% 15% 20% 25% 30% 35% Alternator kW 10% 15% 20% 25% 30% 35% Standard 100 79 118 157 197 236 275 Standard 100 59 89 118 148 177 206 Upsize 1 130 116 174 232 290 348 406 Upsize 1 130 87 131 174 218 261 305 FUEL CONSUMPTION RATES* Natural Gas – ft3/hr (m3/hr)Propane Vapor – ft3/hr (m3/hr) Percent Load Standby Percent Load Standby 25% 494.0 (14.1) 25% 192.1 (5.4) 50% 759.6 (21.5) 50% 290.3 (8.2) 75% 1,011.1 (28.6) 75% 392.6 (11.1) 100% 1,261.4 (35.7) 100% 485.7 (13.8) * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Standby Coolant System Capacity gal (L) 6.0 (22.7) Coolant Flow gal/min (L/min) 27.5 (104) Heat Rejection to Coolant BTU/hr (kW) 390,000 (114.3) Inlet Air cfm (m 3/hr) 5,797 (164.2) Maximum Operating Ambient Temperature °F (°C) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Radiator Backpressure in H2O (kPa) 0.5 (0.12) COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power cfm (m3/min) 282 (7.9) ENGINE EXHAUST Standby Standby Rated Engine Speed rpm 1,800 Exhaust Flow (Rated Output) cfm (m 3/min) 866 (24.5) Horsepower at Rated kW** hp 149 Maximum Exhaust Backpressure inHg (kPa) 1.5 (5.1) Piston Speed ft/min (m/min) 1,273 (388.2) Exhaust Temp (Rated Output - Post Catalyst) °F (°C) 1,200 (649) BMEP psi 125 OPERATING DATA Three-Phase 120/208 VAC @0.8pf 100 kW Amps: 347 * Fuel supply installation must accommodate fuel consumption rates at 100% load. 100%1,261.4 (35.7) SG100 | 9.0L | 100 kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency SPEC SHEET6 of 6 DEMAND RESPONSE READY YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Part No. 0K4291 Rev. E 10/09/17 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. * All measurements are approximate and for estimation purposes only. L W H L L L W W H W H H DIMENSIONS AND WEIGHTS* OPEN SET (Includes Exhaust Flex) L x W x H in (mm) 94.2 (2,394) x 40.0 (1,016) x 47.5 (1,206) Weight lbs (kg) 2,064 (936.2) STANDARD ENCLOSURE L x W x H in (mm) 111.8 (2,840) x 40.5 (1,027.8) x 56.2 (1,427) Weight lbs (kg)Steel: 2,708 (1,228) Aluminum: 2,413 (1,094) LEVEL 1 ACOUSTIC ENCLOSURE L x W x H in (mm) 129.4 (3,287) x 40.5 (1,028) x 56.2 (1,427) Weight lbs (kg)Steel: 2,798 (1,269.2) Aluminum: 2,355 (1,068) LEVEL 2 ACOUSTIC ENCLOSURE L x W x H in (mm) 111.8 (2,840) x 40.5 (1,028) x 68.6 (1,743) Weight lbs (kg)Steel: 3,022 (1,370.8) Aluminum: 2,431 (1,103) LEVEL 1 ACOUSTIC ENCLOSURE L x W x H in (mm)129.4 (3,287) x 40.5 (1,028) x 56.2 (1,427) Steel: 2,798 (1,269.2)Weight lbs (kg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¡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art No. 0604160SSD Rev. E 06/13/19 GENERATOR CONTROLSThe Remote Annunciator Panel provides remote monitoring and annunciation of up to 18 generator parameters using LEDs located on the annunciator keypad. It also provides two system level warnings which are System Ready and Communications OK. The Relay Panel has up to 8 selectable functions on form A relays; multiple relay panels can be connected for all 18 generator parameters. The specific faults can be selected using either the DIP switches located on the annunciator circuit board or through a computer via the RS232 connection on the circuit board. All relays are energized on power up and open during a fault condition. Communication is via a RS485 serial data link and power is supplied by the generator battery (+12 VDC or +24 VDC). The Remote Annunciator Panel complies with NFPA 99 and NFPA 110. Environmental Specifications: Operating Temperature ................................................................................................................................................................... -25 ºC to 60 ºC Humidity .........................................................................................................................................................................0 to 95% Non-Condensing Power Supply ...........................................................................................................................................Generator Battery, +12 or +24 Volts DC Power Usage.....................................................................................................................................................................................6 WattsTypical Communication Line ..................................................................................................................RS485 Fully Isolated Twisted Pair Cable with Shield Maximum Cable Length ...............................................................................................................................................................................4,000 ft Relay Output ...........................................................................One NO Contact (Energized when Annunciator is Powered and No Faults are Present) Relay Contact Rating ............................................................................................................................................................................30 VDC, 1 A Enclosure Rating .........................................................................................................................................................................................NEMA 1 Alarm Horn (Remote Annunciator Panels Only) ...............................................................................................................................90 dB @ 10 cm Model 0054650 Gray Remote Annunciator Panel without Relays Model 0054660 Gray Remote Relay Panel without LEDs and Keypad (Relays Only) Model 0054640 Gray Remote Annunciator Panel with 8 Relays Model 0056370 Tan Flush Mount Enclosure without Annunciator Model 0066950 Gray Flush Mount Enclosure without Annunciator Description: Model 0054640 Gray Remote Annunciator Panel with 8 Relays 2 OF 2 21 LIGHT REMOTE ANNUNCIATOR AND REMOTE RELAY PANEL Part No. 0604160SSD Rev. E 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSFunction Color Alarm Latched Pre-Low Oil Pressure Yellow Yes Yes Pre-High Water Temperature Yellow Yes Yes Pre-Low Water Temperature Yellow Yes Yes Pre-Low Fuel Yellow Yes Yes Battery Charge AC Fail Yellow Yes No Low Battery Voltage Yellow Yes No High Battery Voltage Yellow No No Not in Auto Red Yes No RPM Sensor Loss Red Yes Yes Overcrank Red Yes Yes Overspeed Red Yes Yes Low Oil Pressure Red Yes Yes High Water Temperature Red Yes Yes Low Water Level Red Yes Yes Emergency Stop Red Yes No Gen Running Yellow No No Gen Power (ATS) Yellow No No Line Power (ATS) Green No No Systems Ready Green Yes No Communications OK Green Yes No Spare Green No No Surface Mount Annunciator The 21 Light Annunciator can mount to a flat surface with connections through the 0.812 inch diameter knockout on the back surface or through 0.812 inch diameter knockouts on sides as shown. Flush Mount Annunciator This Flush Mount Box is recessed into the wall opening and the surface mount annunciator mounts to the (4) 4 mm screw holes on the back surface. After wire connections are made the front annunciator cover is attached. 1.649.06 0.86 0.812 Diameter 4.53 0.812 DiameterBoth Sides11.42 10.24 7.09 8.27 9.64 Outside Four Mounting Holes for21 Light Annunciator4-mm -0.7 Female Thread 1.57 Thru 2.32 1.93 R0.59 Both Sides 0.87 1.42 6.49 Cut Rough Opening 6.75” x 9.88” 5.8 Spare Keypad Switch can be used to implement a remote start function (Model 0054640 only). Dimensions are in inches. 1 OF 2 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin No. 0182610SSD Rev. E 09/26/18 ALTERNATOR DATA SHEET K0130124Y21 60Hz ALTERNATOR DATAGeneral Characteristics Voltages (V) 208/240 and 480 Number of Leads 12 Frequency (Hz) 60 Winding Type Reconnectable Phases 3 Air Flow (cfm) 483 Speed (rpm) 1800 Total Harmonic Distortion (%) <5 Excitation System PMG/Brushless Largest Single Harmonic Value (%) <3.5 Insulation Class H Telephone Interference Factor (TIF) <50 Winding Pitch 2/3 Reference Part Number 0J1385F01R, 0L4175V01R, 0J1385E01R, 0L4175E01R Ratings at 0.8 pf based on 40ÝC Ambient Voltage (V)Ý&5LVH Ý&5LVH Ý&5LVH Ý&5LVH kW kVA kW kVA kW kVA kW kVA 208/240 99 124 119 149 130 162 140 175 480 99 124 119 149 130 162 140 175 Base Data at 480V, 162 kVA, 1800 RPM, 60 Hz, 3 Phase Description Value Stator Resistance, Line to Line, High Wye &RQQHFWLRQ0.0250 5RWRU5HVLVWDQFH2.2000 ([FLWHU6WDWRU5HVLVWDQFH30*%UXVKOHVV5.5000/6.0000 ([FLWHU5RWRU5HVLVWDQFH30*%UXVKOHVV0.5155/0.4565 ([FLWDWLRQ:LQGLQJ5HVLVWDQFH30*%UXVKOHVV1.3334/0.5042 Xd, Direct Axis Synchronous Reactance (p.u.) 2.630 X2, Negative Sequence Reactance (p.u.) 0.230 X0, Zero Sequence Reactance (p.u.) 0.030 X’d, Direct Axis Transient Reactance (p.u.) 0.180 X”d, Direct Axis Subtransient Reactance (p.u.) 0.140 Xq, Quadrature Axis Synchronous Reactance (p.u.) 1.150 T’d, Direct Axis Transient Short Circuit Time Constant (s)0.054 Description Value T”d, Direct Axis Subtransient Short Circuit Time Constant (s)0.008 T’do, Direct Axis Transient Open Circuit Time Constant (s)1.235 Ta, Short Circuit Time Constant of Armature Winding (s)0.018 Phase Sequence CCW-NDE T1, T2, T3 Voltage Balance, L-L or L-N (%) 2.5 Deviation Factor (%) 7 High Wye Connection, Sustained 3-Phase Short Circuit Current (%) - PMG only 300 X/R 7 Short Circuit Ratio 0.46 Heat Rejection (BTU/hr) - 100% Rated Load, 480V, 0.8pf, 120oC Temp. Rise 59,916 Reference: Mil-STD-705B All Ratings are Nominal 2 OF 2 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin No. 0182610SSD Rev. E 09/26/18 ALTERNATOR DATA SHEET K0130124Y21 60Hz ALTERNATOR DATAsKVA 10% 15% 20% 25% 30% 35% 480 V @ 0.3PF 77 120 169 223 292 361 480 V @ 0.6PF 94 139 192 251 327 403 208/240 V @ 0.3PF 78 120 169 223 294 365 208/240 V @ 0.6PF 89 137 192 250 327 404 Efficiencies 480 @ 0.8 PF 480 @ 1.0 PF 208/240 @ 0.8PF 208/240 @ 1.0 PF 20% Rated Power* 86.8 88.0 86.9 88.1 40% Rated Power* 89.9 92.0 90.1 92.0 60% Rated Power* 90.0 92.8 90.1 92.8 80% Rated Power* 89.3 92.6 89.1 92.5 100% Rated Power* 88.1 92.1 88.0 92.0 *Rated Power value is rating kW at 120°C Winding Temp Rise and 0.8pf LOG LOG Decrement Curve 10 100 1000 10000 100000 0.001 0.010 0.100 1.000 10.000Output Current (A)Time (s) Balanced 3-Phase Short Circuit Decrement & Thermal Damage Current Limit Curves 208V Decrement Curve 480V Decrement Curve 240V Decrement Curve 208V Thermal Damage Curve 480V Thermal Damage Curve 240V Thermal Damage Curve 208V Control System Shutdown 480V Control System Shutdown 240V Control System Shutdown 1 OF 2 GENprotect ™ Seamless Protection for Industrial Power Generators Doc. No 0187980SBY Rev. D 06/13/19 GENERATOR CONTROLSGENprotect Operation The design choice of an onsite power system using a Generac Industrial Power Generator assures your emergency power source is protected from unexpected power distribution faults. Typically, a generator will include some type of over-current device, such as a circuit breaker, or be protected by inherent design with the controller protecting the alternator through a protection algorithm. Generac’s GENprotect generator protection system monitors the system current output and protects the alternator with extended security against fault scenarios that could occur within the site’s downstream distribution system. It is a common misconception that the alternator’s main circuit breaker protects the alternator from a short circuit event. The main output breaker protects the cabling and provides a convenient disconnect. The characteristic trip curve for the industry standard thermal magnetic breaker (MCCB, molded case thermal magnetic or solid state) does not coordinate with the thermal damage limitation for an on-site generator. If circuit breakers are used for generator protection, a solid-state circuit breaker with full adjustments (Long Time, Short Time and Instantaneous, LSI) is required to coordinate the breaker protection curve within the generator thermal damage curve. Historically, this limitation was often accepted in system design since failures of the main generator feeder are extremely rare. Most short circuit events happen at a branch circuit, equipment level, where the fault is easily cleared by the smaller down stream breakers. Given the mission critical nature of today’s back-up power applications, it is more desirable to protect the system against even relatively rare failure modes. As generator controllers have become more powerful it is feasible for manufactures to supply coordinated short circuit protection integral to the generator control system, negating the need for a main-line circuit breaker. Generac’s GENprotect alternator protection algorithm monitors the generator output. If this monitoring senses short circuit current in excess of rated amps, GENprotect steps in to provide a controlled and safe approach to breaker coordination and alternator protection. GENprotect first limits the alternator short circuit current level to 300%. By limiting the available fault current, GENprotect extends the time the alternator can maintain fault current resulting in consistent breaker coordination. Without this functionality a line to neutral fault may be at 800% of rated current and need to be cleared within 1.4 seconds. The second function GENprotect performs is I2T thermal protection for the alternator. Since a short circuit event can heat the alternator so rapidly, it is not possible to protect the alternator by monitoring temperature. Instead GENprotect calculates the heat energy of the fault current. When this energy reaches the limits of NEMA MG1, GENprotect trips the generator off-line. This configuration ensures the alternator is protected and the power system is ensured 10 seconds of 300% fault current for breaker coordination. DESCRIPTION • GENprotect is an alternator protection algorithm approved by UL. • Protects alternator from damage due to shorts and electrical faults. • Provides breaker coordination and alternator protection. • Allows for use of multiple circuit breaker choices, including “no” breaker. 2 OF 2 Doc. No 0187980SBY Rev. D 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSThe above Figure shows the Generac GENprotect thermal protection curve for use in protection and coordination studies. The alternator Thermal Damage Curve is shown just to the right of the GENprotect protection curve. If the alternator load is greater than the thermal damage protection curve for the alternator, the generator set will trip off-line. For example, an overload current of 110% for 75 seconds causes an overload alarm and will trip the generator off-line, shutting down the engine. GENprotect will provide generator protection over a full range of time and current, from instantaneous faults to overloads lasting several minutes. An advantage of GENprotect over a MCCB is that GENprotect allows for downstream breakers to clear faults without tripping the generator off-line, providing selective coordination with the first level of downstream breakers. GENprotect ™ Seamless Protection for Industrial Power Generators 1 OF 1 INDUSTRIAL GENSET - BATTERY INDEX Part No. 0161970SBY Rev. K 8/02/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.BATTERY OPTIONS• Warranty by Exide Corp. • Exide e-mail: tbgna@exide.com • 800-782-7848 National Hot line Industrial Spark-Ignited Gensets - Available Batteries Engine System Voltage Battery Quantity Generac Part # 058208 (Group 24F) 077483 (Group 26) 058665 (Group 27F) 061119 (Group 31) 061104 (Group 8D) G2.4 12 1 X G4.5 12 1 X X G5.4 12 1 X X X G6.8 12 1 X X G9.0 12 1 X X G14.2 24 2 X G21.9 24 2 X G25.8 24 2 X G33.9 24 4 X X = Battery available with electrolyte and installed in genset. Industrial Diesel Gensets - Available Batteries Engine System Voltage Battery Quantity Generac Part # 058665 (Group 27F) 061119 (Group 31) 061104/BT0015A00 (Group 8D) BT0015A02 (Group 8D) D2.2 Perkins 12 1 X X D2.4 Generac 12 1 X X D3.4 Generac 12 1 X X D4.5 FPT 12 1 X D6.7 FPT 100, 130kW 12 1 or 2 †X D6.7 FPT 150, 175kW 12 2 †X D8.7 FPT 24 2 X D10.3 FPT 24 2 X X D12.9 FPT 24 2 X X D12.5 Perkins 24 2 X D15.2 Perkins 24 2 X D16.0 Volvo 24 2 X X D18.1 Perkins 24 2 X D33.9 MHI 24 2 X X D37.1 MHI 24 4 X X D49.0 MHI 24 4 X X D65.4 MHI 24 4 X X X = Battery available with electrolyte and installed in genset.† = Single or dual-paralleled battery options are available on 100 and 130kW. Single-battery option not available on 150 and 175kW. Part Number Group Number* Nominal CCA @ 0° F Dimensions (in) Nominal LWH 058208 24F 525 6.75 10.63 9.00 077483 26 525 6.75 8.25 7.75 058665 27F 700 6.75 12.50 9.00 061119 31 925 6.75 13.00 9.40 061104/ BT0015A00 8D 1,155 11.00 20.80 10.00 BT0015A02 8D 1,300 11.00 20.80 10.00 All batteries are 12V, 6 cell construction, lead calcium type. For 24V systems, batteries are wired in series. * BCI Group Size reference. ** Add an “A” suffix to the Generac part number for dry batteries, which are shipped without electrolyte. G9.0 12 1 X 061119 (Group 31) 061119 31 925 6.75 13.00 9.40 1 OF 3ENCLOSUREGENERATOR ENCLOSURES DESCRIPTION GENERAC POWER SYSTEMS’ generator enclosures provide year-round weather protection for your power equipment. Engineered with functionality and value in mind, the enclosure design benefits are unique in that the enclosures utilize dimensionally matched components for either a weather protective configuration or a sound attenuated/acoustic configuration. With common components used between design, modification and on-site upgrades can be accomplished with ease. The enclosure design offers several benefits over the “standard enclosures” of other manufacturers. Generac’s enclosures have been created with the goal of maximizing the customer’s product performance satisfaction while maintaining the functionality of reducing exterior noise levels and discouraging product tampering. Although others may require a “premium” for a self-enclosed exhaust system, rugged steel panel construction or protective polyethylene washers under all exterior panel fasteners, Generac includes these and several other features on every enclosure configuration. Be sure to compare. Generac Enclosures offer additional design enhancement extras that other “standard enclosures” do not. Doc No. 0163180SBY Rev. E 06/10/19 2 OF 3ENCLOSUREGENERATOR ENCLOSURES Post-Free Twin Doors Provide Large, Unobstructed Service Access Gasket-Free, Interconnected Roof Panel Joint Drip-Free, Maintenance-Free Heavy Gauge, Stainless Steel, Partial Pin Hinges with Nylon Spacers Durable, Corrosion-Free, Removable Doors Lockable Turn and Tuck Stainless Steel Latch Handle Corrosion-Free, Non- Protruding and Secure Dense, Closed-Cell Foam Insulation with Reflective Silver Mylar Layer Improved Sound Attenuation Without Damaging Effects From Radiant Heat Exposure Two-Point Door Latch System Ensures Proper Seal Preventing Water Ingress and Sound Egress Doc No. 0163180SBY Rev. E 06/10/19 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 3 OF 3ENCLOSURE Doc No. 0163180SBY Rev. E 06/10/19 GENERATOR ENCLOSURES FEATURES: BENEFITS: Dimensional matching of acoustic and non-acoustic enclosure designs Reduces variation in fuel tank pricing, inventory; removes need to change out fuel tank or retrofit Standardized enclosure components * Ease of retrofit or upgrade to acoustic system; reduced parts inventory, costs Enclosure mounted directly to unit baseframe Simplified delivery and installation with enclosure and unit in single component design Electrostatically painted panels Maximum protection from weather elements 12 or 14 gauge steel based on kW rating Maximum sound attenuation, protection and product life Aluminum Enclosure optional Prevents corrosion in coastal regions Stainless steel door latch and hinge hardware Provides extended component life; maximum protection against rusting Stainless steel door latch strike plate Maximum protection against enclosure paint damage from door latch pin Door hinges utilize slip-pin design Provides quick door removal for full-unit access Polyethylene gasketing under door hinges Additional protection for enclosure paint finish Keyed door latches Protection for equipment and personnel Large removable access doors Ease of maintenance Relocation of access doors Provides improved access to MLCB on all units Redesigned door gasketing Improved sealing quality from sound and weather elements Weather resistant aluminum roof design with drip ledge Provides optimum moisture/rain runoff from unit Cabled and gasketed radiator access cover Provides improved radiator access and additional protection from weather elements Acoustic roof panels manufactured with mechanical retention pins Increased acoustic foam retention within unit Polyethylene washers under all panel fasteners Additional paint finish protection from stainless steel fastener Internally fastened enclosure panels (where possible) Provides streamlined unit appearance Additional roof panel stiffener Added overall compartment rigidity and acoustic foam panel retention Self-enclosed exhaust system Provides safe unit operation; no enclosure hot spots; streamlined unit appearance Discharge air duct has been designed with minimal fasteners Ease of removal and access to exhaust system Stainless steel exhaust band clamps Provides extended component life; ensures proper exhaust seal Drain holes within air ducts Enables maximum water run-off Rodent-proof, tamper proof enclosure design Safety and security for personnel and equipment Redesigned baseframe lifting lugs Ease of unit relocation; prevents compartment damage from lifting straps Up to 200 MPH wind kit options (Contact Factory for Availability) Meets locally enforced wind requirements * Consult Generac Power Systems, Inc. for installation drawings for specific configurations and dimensions. 1 OF 1 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. RhinoCoat™ Part No. 0180230SBY Rev.D 06/18/19 UNIT OPTIONSGenerac’s RhinoCoat™ finish system provides superior durability as a standard for all Generac Industrial enclosures, tanks and frames.* Testing Standards Generac’s RhinoCoat™ finished surfaces are subjected to numerous tests. These include: • ASTM D - 1186 - 87..............................................................................................................2.5+ MIL Paint Thickness • ASTM D - 3363 - 92a............................................................................................................Adequate Material Hardness • ASTM D 522 - B....................................................................................................................Resistant To Cracking • ASTM D 3359 - B..................................................................................................................Exceptional Adhesion • ASTM B117 D 1654..............................................................................................................Resistant to Salt Water Corrosion • ASTM D1735 D 1654............................................................................................................Resistant to Humidity • ASTM 2794 93 (2004)..........................................................................................................Exceptional Impact Resistance • SAEJ1690 - UV Specifications...............................................................................................UV Protection In addition to the testing standards above, Generac adds the following test requirements more specific to generator applications: • Resistant to Typical Oils • Resistant to Typical Fuels • Resistant to Typical Antifreeze • Resistant to Distilled Water Primary codes and standards *RhinoCoat powder coat paint is durable and corrosion resistant however it is not a rust preventative. Generac pretreats all powder coated parts to assist with resistance to corrosion. 1 OF 2 EATON CIRCUIT BREAKER DATA Standard (80% Rated) Thermal-Magnetic Part No. 0189370SSD Rev. E 06/13/19 CIRCUIT BREAKERSAMPS VOLTS ACCESSORIES EATON PART No. SERIES FRAME GENERAC PART No. 15 600 No Accessories FG3015 C F-Frame 0H9294TA00 Shunt Trip & Aux. Contacts FG3015A12S03 0H9294TAB0 20 No Accessories FG3020 0H9295TA00 Shunt Trip & Aux. Contacts FG3020A12S03 0H9295TAB0 25 No Accessories FG3025 0J0248TA00 Shunt Trip & Aux. Contacts FG3025A12S03 0J0248TAB0 30 No Accessories FG3030 0H9296TA00 Shunt Trip & Aux. Contacts FG3030A12S03 0H9296TAB0 35 No Accessories FG3035 0H9297TA00 Shunt Trip & Aux. Contacts FG3035A12S03 0H9297TAB0 40 No Accessories FG3040 0H9298TA00 Shunt Trip & Aux. Contacts FG3040A12S03 0H9298TAB0 45 No Accessories FG3045 0H9299TA00 Shunt Trip & Aux. Contacts FG3045A12S03 0H9299TAB0 50 No Accessories FG3050 0H9300TA00 Shunt Trip & Aux. Contacts FG3050A12S03 0H9300TAB0 60 No Accessories FG3060 0H9301TA00 Shunt Trip & Aux. Contacts FG3060A12S03 0H9301TAB0 70 No Accessories FG3070 0H9302TA00 Shunt Trip & Aux. Contacts FG3070A12S03 0H9302TAB0 80 No Accessories FG3080 0J0841TA00 Shunt Trip & Aux. Contacts FG3080A12S03 0J0841TAB0 90 No Accessories FG3090 0J0837TA00 Shunt Trip & Aux. Contacts FG3090A12S03 0J0837TAB0 100 No Accessories FG30100 0H9314TA00 Shunt Trip & Aux. Contacts FG3100A12S03 0H9314TAB0 125 No Accessories FG30125 0J0231TA00 Shunt Trip & Aux. Contacts FG3125A12S03 0J0231TAB0 150 No Accessories FG30150 0H9315TA00 Shunt Trip & Aux. Contacts FG3150A12S03 0H9315TAB0 175 No Accessories FG30175 0H9316TA00 Shunt Trip & Aux. Contacts FG3175A12S03 0H9316TAB0 200 No Accessories FG30200 0J0232TA00 Shunt Trip & Aux. Contacts FG3200A12S03 0J0232TAB0 225 No Accessories FG3225 0H9317TA00 Shunt Trip & Aux. Contacts FG3225A12S03 0H9317TAB0 250 No Accessories JG3250 J-Frame 0H9318TA00 Shunt Trip & Aux. Contacts JG3250A12S43 0H9318TAB0 300 No Accessories KG3300 K-Frame 0H9319TA00 Shunt Trip & Aux. Contacts KG3300A12S43 0H9319TAB0 2 OF 2 Part No. 0189370SSD Rev. E 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.CIRCUIT BREAKERSEATON CIRCUIT BREAKER DATA Standard (80% Rated) Thermal-Magnetic AMPS VOLTS ACCESSORIES EATON PART # SERIES FRAME GENERAC PART # 350 600 No Accessories KG3350 C K-Frame 0H9320TA00 Shunt Trip & Aux. Contacts KG3350A12S43 0H9320TAB0 400 No Accessories KG3400 0H9321TA00 Shunt Trip & Aux. Contacts KG3400A12S43 0H9321TAB0 450 No Accessories LG3450 L-Frame 0H9322TA00 Shunt Trip & Aux. Contacts LG3450A12S03 0H9322TAB0 500 No Accessories LG3500 0H9323TA00 Shunt Trip & Aux. Contacts LG3500A12S03 0H9323TAB0 600 No Accessories LG3600 0H9324TA00 Shunt Trip & Aux. Contacts LG3600A12S03 0H9324TAB0 700 No Accessories MDL3700 M-Frame 0H9325TA00 Shunt Trip & Aux. Contacts MDL3700A06S02 0H9325TAB0 800 No Accessories MDL3800 0H9326TA00 Shunt Trip & Aux. Contacts MDL3800A06S02 0H9326TAB0 900*No Accessories NG3900 N-Frame 0H9327TA00 Shunt Trip & Aux. Contacts NG3900A12S03 0H9327TAB0 1,000*No Accessories NG31000 0H9328TA00 Shunt Trip & Aux. Contacts NG31000A12S03 0H9328TAB0 1,200*No Accessories NG31200 0H9329TA00 Shunt Trip & Aux. Contacts NG31200A12S03 0H9329TAB0 1,400*No Accessories RGH316033MY22 G RG-Frame 0H9360EAN0 Shunt Trip & Aux. Contacts RGH316033MA12S21Y22 0H9360EANB 1,600*No Accessories RGH316033MY22 0H9361EAN0 Shunt Trip & Aux. Contacts RGH316033MA12S21Y22 0H9361EANB 2,000*No Accessories RGH320033M 0H9367EAN0 Shunt Trip & Aux. Contacts RGH320033MA12S21 0H9367EANB 2,500*No Accessories RGH325033M 0H9368EAN0 Shunt Trip & Aux. Contacts RGH325033MA12S21 0H9368EANB *LS-type electronic trip breaker equipped with RMS 310+ trip unit. No Accessories KG3400 0H9321TA00400 1 OF 1 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. BATTERY CHARGER 2.5 amp and 10 amp Part No.0191900SBY Rev. E 08/12/19 GENERATOR CONTROLSThe Generac 2.5 amp 12 volt and 10 amp 12/24 volt battery chargers are designed to work with Generac Industrial Controls to provide the ultimate in automatic battery voltage maintenance. The 2.5 amp charger is self-regulating and produces instantaneous output current adjustments to keep the battery charged to an optimum level. Battery voltage is read on the control panel digital display. The 10 amp charger has automatic float and equalize control. It precisely monitors the battery’s voltage and automatically activates the correct charging mode. The charge rate is limited and controlled to efficiently and safely maintain ideal battery levels under varying conditions. The equalize system uses a control circuit to limit charging current to 10 amps. When battery voltage drops below a preset level, charging current increases to 5 amps and then to the 10 amp charge rate if needed. When the battery reaches maximum charge, the charger switches to float mode to supply just enough current to maintain the battery at or above 13/26 volts. Battery voltage and charging current are read at the control panel digital display. Battery charger shown from inside of control panel enclosure. Connections are made via an attached harness. Specifications 2.5A 10A Nominal Input 120 VAC 120 VAC Operating AC Line Voltage Range 108 to 132 VAC 108 to 132 VAC Input AC Line Frequency 50/60 Hz 50/60 Hz Battery Fuse N/A 15 A Nominal Charge Rate 2.5 A 10 A Equalize Voltage N/A 13.8/27.6 V Float Voltage 13.4 V 13.0/26.0 V Current @ Equalize to Float Transition N/A 5 A Battery Under-voltage shutdown N/A 11/22 V LED Indicators No Yes AC Line Voltage N/A Green LED Battery Connected and Charging N/A Yellow LED Battery Current Drain 30 mA 30 mA AC Line Connection Connector Plug Connector Plug Battery Connection Connector Plug Connector Plug Control Connection AC Power Fail Form Relay Form C 2 A Rating CUL Recognized Yes Yes NFPA 110 Compliant No Yes AGM Compatible No Yes UL1236 No Yes CSA 22.2 No. 107 No Yes 10A Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 1 OF 1 CIRCUIT BREAKERSPart No. 0192390SSD Rev. J 06/18/19 EATON CIRCUIT BREAKER DATA LUG INFORMATION Eaton Series C Circuit Breaker Lugs Standard Lug Amps Series Frame Eaton Part # Wire (QTY) Size 15-70 C G - (1) #10-1/0 15-100 C F 3T100FB (1) #14-1/0 125-200 C F 3TA225FD (1) #4-4/0 225 C F 3TA225FDK (1) #6-300MCM 250 C J TA250KB (1) #4-350MCM 300 C K TA350K (1) 250-500MCM 350-400 C K 3TA400K (2) 3/0-250MCM 450-500 C L TA602LD (2) 3/0-350MCM 600 C L 3TA603LDK (2) 400-500MCM 700-800 C M TA800MA2 (3) 3/0-400MCM 900-1,000 C N T1200NB3 (4) 4/0-500MCM 1,200 C N TA1201NB1 (3) 500-750MCM Eaton Series G Circuit Breaker Lugs Amps Series Frame Standard Lug Eaton Part # Wire (Qty) Size 50-250 G JG TA250FJ (1) #4-350MCM 300-600 G LG 3TA632LK (2) #2-500MCM 900-1,200 G NG TA1201NB1 (3) 500-750MCM 1,400-1,600 G RG T1600RD (4) 1-600MCM 2,000 G RG Lugs Not Included 2,500 G RG Lugs Not Included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enerac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. ELECTRONIC GOVERNOR Spark-Ignited Engines Part No. 0604400SSD Rev. J 10/08/19 GENERATOR CONTROLSGenerac’s electronic isochronous governor systems are standard on all Spark-Ignited gensets utilizing Generac’s Digital Control Platforms. • Isochronous Speed Regulation • ±0.25% Steady State Regulation • Factory Installed and Adjusted • Fully Adjustable • Quiet-Test™ Low-Speed Exercise Capability • Fast Response • High Reliability • Environmentally Sealed Die cast enclosure housing the throttle plate and the gear-driven rotary actuator with the interior components sealed against dust, dirt and moisture. The gear drive is directly connected to the throttle plate for fast and precise control. Safety spring-return to a closed position upon loss of power. Design ..........................................................................................................................................................................................................................Bosch Type.................................................................................................................................................................................Electronically Actuated Throttle Valve Operating Voltage .....................................................................................................................................................................................................12/24VDC Response Time ........................................................................................................................................................................................................ <100 ms Operating Temperature Range ...........................................................................................................................................................................Ý)WRÝ) Output ..........................................................................................................................................................................................Rotary (internal - no linkage) ACTUATOR CONTROLLER The governor driver module is located in the generator control panel. A sealed unit with waterproof connections and a feedback circuit from the actuator for throttle plate position. Generac software controls speed governing, and is fully adjustable. The Generac electronic governor system applies to all spark-ignited gensets with Generac’s Digital Control Platforms. *(1(5$725&21752/62) 3DUW1R4*HQHUDF3RZHU6\VWHPV,QF_32%R[_:DXNHVKD:,3*HQHUDF3RZHU6\VWHPV,QF$OOULJKWVUHVHUYHG$OOVSHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH &22/$17+($7(5237,21 :$779$& >@ >@ >@ 3/$&(6 >@ >@ >@ +26(%$5%72),7µ,'+26( 3/$&(6 >@ 287/(7 ,1/(7 >@ >@ ',0(16,216PP>,1&+(6@ 63(&,),&$7,216 92/7$*(9$& +($732:(5: ),;('7+(50267$7) +($7,1*(/(0(17,1&2/2< 0$;,08035(6685(36,N3D 3/8*1(0$67'3 1 OF 2 REMOTE EMERGENCY STOP SWITCH Break Glass, H-Panel Part No. 0L6262 Rev. B 07/10/19 GENERATOR CONTROLSGenerac Part Number: 061129D Surface Mount, NEMA 3R 2 Replacement Glasses Painted Steel Enclosure Contact Rating: 10A at 120V Specifications Dimensions: mm [in]57 [2.24] 3X ø 6 [0.24] 32 [1.26] 124.5 [4.90] 140 [5.51] 120 [4.72] 120 [4.72] 93.5 [3.68] 108 [4.2] 115.5 [4.55] 1/2 - 3/4 Knockout 114 [4.49] 58 [2.3] 1/2 - 3/4 Knockout 57 [2.24] 63.5 [2.50] 31.8 [1.25] 66.7 [2.62] 33.3 [1.31] 2 OF 2 REMOTE EMERGENCY STOP SWITCH Break Glass, H-Panel Part No. 0L6262 Rev. B 07/10/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSWiring - H-Panel EXISTING H-PANEL INTEGRATED SWITCHHARNESS CONNECTOR H-PANEL REMOTE EXISTING ENGINE E-STOP HARNESSCONNECTORS CONNECTORHARNESS REMOTE E-STOP SHIPPED LOOSE NOTES: FACTORY WIRED JUMPER FOR TESTINGPURPOSES ONLY OR IF REMOTE E-STOP NOTPRESENT. CUSTOMER TO REMOVE WHEN INSTALLING REMOTE E-STOP E-STOP WAS ACTIVATED, BUT WILL STOP UNIT FROMRUNNING 1) THE H-PANEL REMOTE E-STOP HARNESS IS SHOWNIN POSITION BETWEEN EXISTING INTEGRATED SWITCHCONNECTOR AND ENGINE HARNESS CONNECTOR. CONNECTION POINT IS LOCATED BEHIND THE H-PANELHINGED COVER 2) SEE WIRING OR SCHEMATIC DIAGRAM(S) SPECIFIC TOUNIT FOR INFORMATION ON OTHER WIRES 3) FACTORY RUNS WIRING OUT OF H-PANEL ALONGENGINE HARNESS THAT ENTERS LOW VOLTAGE CUSTOMER CONNECTION BOX. TIE WRAP ALONG HARNESS AS NEEDED.4) THE H-PANEL WILL NOT RECOGNIZE THAT REMOTE CUSTOMER INSTALLED & WIREDWIRE TO NORMALLY CLOSEDPART OF SWITCH FACTORY WIRED VIA H-PANEL REMOTE LOCATED IN LOW VOLTAGE CUSTOMER CONNECTION BOX NEAR TB2 E-STOP HARNESS RELAY SOCKET RELAY SOCKET SWC1 SWC2 4321431ABABDIM ZCOGDIM YCOGDIM XCOG3287.2[129.42]OVERALL LENGTH1162.7[45.78]200.2[7.88]TYP453.5[17.85]2360[92.91]1162.7[45.78]453.5[17.85]1027.8[40.46]OVERALL WIDTH1203.6[47.39]1403.8[55.27]940.1[37.01]1427[56.18]OVERALLHEIGHTGENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2012ELECTRONICALLY APPROVEDINSIDE WINDCHILLDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.SH1/1REVC-1TITLEL1A ENCLOSUREG8.0L, 60HZ: SG080, PG072 50HZ: SG064, PG058G9.0L, 60HZ: SG100, PG090 50HZ: SG080, PG072ISSUE DATE: 07/25/14SIZE CAGE NO DWG NO0K0383B REVBC-1SCALE0.050 WT-KG SHEET1 of 1GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2012ELECTRONICALLY APPROVEDINSIDE WINDCHILLDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.DIMENSIONS ARE IN MILLIMETERS [INCHES]FOR ALL STUB-UP, WEIGHT, AND COG DETAILS, SEECORRESPONDING OPEN SET DRAWING PER UNIT CONFIGURATIONAIR INTAKERADIATOR/EXHAUSTDISCHARGE AIRAIR INTAKE (BOTH SIDES)DISCHARGE AIRRADIATOR & EXHAUSTAIR INTAKE(BOTH SIDES)AIR INTAKEAIR INTAKEAIR INTAKER440.4[17.34]TYP DOOR SWING Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 1 OF 1INSTALLATION Part No. 10000002132 Rev. A 03/15/16 GAS SUPPLY CHECK LIST Ƒ Gas Service Meter & Serving Utility ż Available on site & reliable ż Rated for the combined loading of the facility and the generator (total BTU). ż Maintains generator minimum pressure requirements while under maximum loading Ƒ Step Down Pressure Regulators ż Selected for the pressure & flow needs of the generator ż Direct acting type with good dynamic response (no significant time lags in regulation) ż Selected for minimum no-load to full load pressure droop (< 1-2” w.c desired) ż Located near the generator (allows the long piping runs to be at higher pressure) ż Located at least 10’ away from generator connection (avoids regulator oscillations) ż Dedicated to a single generator (increases system reliability) Ƒ Piping ż Sized large enough to minimize pressure drops to acceptable levels under full gas flow ż Minimize the number of elbows to avoid unwanted pressure drops ż Ensure entire gas supply system maintains acceptable generator pressure under full gas flow conditions ż Should be connected to generator with a flexible connection ż Should include a drip leg (sediment trap) Ƒ LP ż LP tank’s boil off rate (BTU capacity) needs to support rated BTU at minimum ambient. ż LP liquid withdrawal systems should be considered: cold ambients, small tanks, large generators ż LP liquid systems require pressure rated piping and vaporization outside a building Ƒ Generac Design Resources ż “Installation Guidelines for Stationary Industrial Generators” manual 046622 (detailed information) ż “Power Design Pro” software -- mechanical design tab (gas piping pressure drop calculator) Ƒ National Codes & Standards ż NFPA 37 “Installation and use of Stationary Combustion Engines” ż NFPA 54 “National Fuel Gas Code” ż NFPA 58 “LP Gas Code” 4321431ABAB DIM XCOGNOT 6 SHEET 3 DIM Y COGNOTE 6SHEET 3 DIM ZCOGNOTE 6, SHEET 32360[92.9]OVERALL LENGTH2X270[10.6]2X1780[70.1]1206[47.5]EXHAUSTHEIGHT1425[56.1]2X105[4.1]1210[47.7]FLEX PIPE(NOTE 7, 12)1290[50.8]FLEX PIPE(NOTE 7, 12)1218[48.0]OVERALLHEIGHT202[8.0]AIRDUCT(NOTE 10)940[37.0]1016[40.0]OVERALL WIDTH2357[92.8]USING ONLY FACTORYSUPPLIED COMPONENTS130[5.1]LPLINLET1400[55.1]LPL INLET1600[63.0]670[26.4]LOW VOLTAGECONNECTION BOXHEIGHT& MLCBHEIGHT(NOTE 5)1031[40.6]HIGH VOLTAGECONNECTION BOXHEIGHT791[31.2](SEE NOTE 16)140[5.5]FLEX PIPE RH864[34.0]FLEX PIPE LH531[20.9]CUSTOMERHIGH VOLTAGECONNECTION(NOTE 5)551[21.7]EXHAUSTPIPIE(NOTE 7)693[27.3]AIR DUCT(NOTE 10)161[6.3]AIR DUCT(NOTE 10)810[31.9]AIR DUCT(NOTE 10)105[4.1]600[23.6]OIL DRAIN(NOTE 7)133[5.2]TITLEOPEN SET G9.0L 60 HZ: SG080, PG072SG100. PG090 ISSUE DATE: 4/3/17 SIZE CAGE NO DWG NO10000013539 REVBN/A ASCALE0.040 WT-KG N/A SHEET1 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.SH1/3REVWINDCHILL VERSIONHIGH VOLTAGECONNECTION BOX(NOTE 8)NOTE 4ALTERNATOR AIROUTALTERNATOR AIROUTLIFTING EYE(4 PLACES)51 X 80 SLOT[2 X 3]DIMENSIONS ARE IN MILLIMETERS [INCHES]THIS DRAWING APPLIES TO GENERATORS USING ENGNE DESIGNATION G26. SEE DOCUMENT 0185560SSDTO DETERMINE THE ENGINE DESIGNATION FOR YOUR GENERATOR.PRIMARY FUEL INLET(NOTE 7)LP LIQUID FUEL INLET(NOTE 7)NOTE 1LOW VOLTAGECONNECTION BOX(NOTE 3)FLEX PIPE(NOTE 7)NOTE 17NOTE 13OUTLETLOCATION(NOTE 2)SECONDARYFUEL INLET(NOTE 7)OIL DRAINSECONDARY HIGHVOLTAGE CONNECTIONBOX LOCATION (OPTIONAL)LOAD CENTERRADIATOR DRAIN(NOTE 7)EXHAUST OUTLET(NOTE 7)15. BLANKETS SHOULD NOT COVER OXYGEN SENSOR.16. OXYGEN SENSOR MUST BE MOUNTED BETWEEN ENGINE OUTLET AND SILENCER INLET AS SHOWN. IF ELBOW IS REQUIRED, ONLY SINGLE ELBOW MAY BE USED. 17. CATALIZED SILENCER (FOR EPA UNITS) MUST BE MOUNTED IN DESCRIBED POSITION. FAILING TO FOLLOW THESE INSTRUCTIONS WHEN INSTALLING A CERTIFIED ENGINE IN A PIECE OF STATIONARY EQUIPMENT VIOLATES FEDERAL LAW 40 CFR 1068.105(b), SUBJECT TO FINES OR PENALTIES AS DESCRIBED IN THE CLEAN AIR ACT.Notes: 1. CONTROL PANEL, (OPTIONAL BATTERY CHARGER INSIDE). 2. 120V, 20A GFCI & 250V, 15A OUTLET (OPTIONAL). 3. CONNECTION POINTS FOR CONTROL WIRES PROVIDED IN THE LOW VOLTAGE CONNECTION BOX (USE LOW VOLTAGE STUB-UP AREA). 4. BATTERY (12 VOLT NEGATIVE GROUND SYSTEM). 5. MAIN LINE CIRCUIT BREAKER (MLCB), AC LOAD LEADS. (DIMENSIONS MAY VARY DUE TO UNIT CONFIGURATION) 6. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 7. ENGINE SERVICE CONNECTIONS: INLET NATURAL GAS = 1-1/4" FEMALE NPT COUPLING INLET DIESEL = N/A RETURN DIESEL = N/A OIL DRAIN = 1/2" NPT FEMALE COUPLING RADIATOR DRAIN = 3/8" BARB FITTING FLEX PIPE OUTLET = 2.5" I.D. EXHAUST OUTLET = 2.5" O.D.***** SEE GENERATOR SIZING GUIDE FOR FUEL PIPE SIZING TO SUIT APPLICATION ***** 8. AUXILARY AC CONNECTION FOR UNIT OPTIONS ARE LOCATED IN HIGH VOLTAGE CONNECTION BOX, UNLESS AN OPTIONAL LOAD CENTER IS INSTALLED. 9. EXHAUST PIPES MAY BE ROTATED TO ALLOW MUFFLER TO POINT OUT TO THE RIGHT OR LEFT SIDE OF GENERATOR. (MAY NOT APPLY TO ALL UNITS)10. GENERATOR SET MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND DISCHARGE AIR FROM THE RADIATOR IS NOT RECIRCULATED.11. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.12. EXHAUST SYSTEM MAXIMUM BACK PRESSUE = 37 INCHES H20.13. INSTALL EXHAUST BLANKETS ALONG THIS LINE.14. CONNECT THE OPEN SET EXHAUST PER NFPA 37ADDITIONAL NOTES: FOR WEIGHT AND CENTER OF GRAVITY DATA SEE NOTE 6, AND SHEET 3. 18. BOLTS OR STUDS USED TO MOUNT UNIT TO PAD SHALL BE 5/8 - 11 GRADE 5. 4321431ABAB300[11.8}80[3.1]855[33.7]906[35.7]1003[39.5]OVERALLWIDTH 2X99[3.9]2X541[21.3]2X1081[42.6]2X1622[63.8]2X2162[85.1]2X254[10.0]235[9.3]OPEN AREAFOR STUB-UP385[15.2]235[9.3]OPEN AREAFOR STUB-UP2X74[2.9]2X47[1.9]2X120[4.7]2X41[1.6]2X312[12.3]OPEN AREAFOR STUB-UP2360[92.9]OVERALL LENGTH508[20.0]DRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.TITLESTUB-UP VIEWG9.0L, 60HZ: SG080, PG072SG100, PG090ISSUE DATE: 04/03/16SIZE CAGE NO DWG NO10000013539REVBN/A ASCALE0.120 WT-KG N/A SHEET2 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUTTHE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLSH2/3REVAWINDCHILL VERSIONA.2RECOMMENDED ELECTRICAL STUB-UP(HIGH VOLTAGE STUB-UP)AC LOAD LEAD CONDUIT FORPERMANENT MAGNET EXCITATIONCONNECTION BOXLOW VOLTAGE STUB-UPPRIMARY HIGH VOLTAGE STUB-UP AREAW/ GLAND PLATEPRIMARY CB CONNECTION BOX OPENINGSECONDARY HIGH VOLTAGESTUB-UP AREA(OPTIONAL)SECONDARY CB CONNECTIONBOX OPENING(OPTIONAL)GLAND PLATES MUST BEREMOVED BEFORE UNIT ISMOUNTED DIRECTLY TOCONCRETE PADLOWVOLTAGESTUB-UP 4321431ABABDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.TITLEWEIGHT & CENTER OF GRAVITYG9.0L 60HZ: SG080, PG072SG100, PG090ISSUE DATE: 04/3/17SIZE CAGE NO DWG NO10000013539REVBN/A ASCALE0.040 WT-KG N/A SHEET3 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUTTHE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLSH3/3REVAWINDCHILL VERSIONA.2MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG 080, PG 072 240V, 11,018 kg [2,245 lbs] 1308 [51.5] 509 [20.1]466 [18.3]SG 080/100, PG 072/090 240V, 1 (100kw)1,068 kg [2,355 lbs] 1275 [50.2] 506 [19.9]SG 100, PG 090 240v, 1 (130kw UPSIZED)1,132 kg [2,496 lbs] 1229 [48.4] 502 [19.8]SG 080, PG 072 208V, 240V, 480V, & 600V1,023 kg [2,256 lbs] 1305 [51.4] 509 [20.0]SG 080/100. PG 072/090 208V, 240V, 480V, & 600V (100kw)1,075 kg [2,371 lbs] 1271 [50.1] 506 [19.9]SG 100, PG 090 208V, 240V, 480V, & 600V (130kw UPSIZED)1,153 kg [2,543 lbs] 1218 [47.9] 501 [19.7]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG 080, PG 072 240V, 11,258 kg [2,774 lbs] 1343 [52.9] 577 [22.7]444 [17.5]SG 080/100, PG 072/090 240V, 1 (100kw)1,308 kg [2,884 lbs] 1315 [51.8] 572 [22.5]SG 100, PG 090 240v, 1 (130kw UPSIZED)1,372 kg [3,025 lbs] 1275 [50.2] 566 [22.3]SG 080, PG 072 208V, 240V, 480V, & 600V1,263 kg [2,785 lbs] 1341 [52.8] 577 [22.7]SG 080/100. PG 072/090 208V, 240V, 480V, & 600V (100kw)1,315 kg [2,900 lbs] 1312 [51.6] 571 [22.5]SG 100, PG 090 208V, 240V, 480V, & 600V (130kw UPSIZED)1,393 kg [3,072 lbs] 1266 [49.8] 564 [22.2]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG 080, PG 072 240V, 11,331 kg [2,935 lbs] 1283 [50.5] 591 [23.3]445 [17.5]SG 080/100, PG 072/090 240V, 1 (100kw)1,381 kg [3,045 lbs] 1259 [49.6] 585 [23.0]SG 100, PG 090 240v, 1 (130kw UPSIZED)1,445 kg [3,186 lbs] 1224 [48.2] 579 [22.8]SG 080, PG 072 208V, 240V, 480V, & 600V1,336 kg [2,946 lbs] 1281 [50.4] 590 [23.2]SG 080/100. PG 072/090 208V, 240V, 480V, & 600V (100kw)1,388 kg [3,061 lbs] 1256 [49.4] 585 [23.0]SG 100, PG 090 208V, 240V, 480V, & 600V (130kw UPSIZED)1,466 kg [3,233 lbs] 1215 [47.9] 577 [22.7]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG 080, PG 072 240V, 11,389 kg [3,062 lbs] 1366 [53.8] 665 [26.2]443 [17.4]SG 080/100, PG 072/090 240V, 1 (100kw)1,439 kg [3,172 lbs] 1340 [52.8] 657 [24.7]SG 100, PG 090 240v, 1 (130kw UPSIZED)1,503 kg [3,314 lbs] 1303 [51.3] 648 [25.5]SG 080, PG 072 208V, 240V, 480V, & 600V1,394 kg [3,073 lbs] 1364 [53.7] 664 [26.1]SG 080/100. PG 072/090 208V, 240V, 480V, & 600V (100kw)1,446 kg [3,188 lbs] 1337 [52.6] 656 [25.8]SG 100, PG 090 208V, 240V, 480V, & 600V (130kw UPSIZED)1,524 kg [3,360 lbs] 1294 [50.9] 645 [25.4]OPEN SETWEIGHTCENTER OF GRAVITYDIM "X"CENTER OF GRAVITYDIM "Y"CENTER OF GRAVITYDIM "Z"1,136 kg [2,504 lbs] 1338 [52.7] 547 [21.5]500 [19.7]1,186 kg [2,615 lbs] 1307 [51.5] 543 [21.4]1,250 kg [2,756 lbs] 1264 [49.8] 538 [21.2]1,141 kg [2,515 lbs] 1335 [52.6] 547 [21.5]1,193 kg [2,630 lbs] 1304 [51.3] 542 [21.3]1,271 kg [2,802 lbs] 1253 [49.3] 536 [21.1]WEIGHTCENTER OF GRAVITYDIM "X"CENTER OF GRAVITYDIM "Y"CENTER OF GRAVITYDIM "Z"1,168 kg [2,630 lbs] 1308 [51.5] 555 [21.9]440 [17.3]1,218 kg [2,685 lbs] 1280 [50.4] 550 [21.7]1,282 kg [2,826 lbs] 1239 [48.8] 545 [21.5]1,173 kg [2,586 lbs] 1306 [51.4] 555 [21.9]1,225 kg [2,701 lbs] 1276 [50.2] 550 [21.7]1,303 kg [2,873 lbs] 1229 [48.4] 543 [21.4]WEIGHTCENTER OF GRAVITYDIM "X"CENTER OF GRAVITYDIM "Y"CENTER OF GRAVITYDIM "Z"1,193 kg [2,630 lbs] 1308 [51.5] 594 [23.4]439 [17.3]1,243 kg [2,740 lbs] 1280 [50.4] 587 [23.1]1,307 kg [2,881 lbs] 1239 [48.8] 580 [22.8]1,198 kg [2,641 lbs] 1306 [51.4] 593 [23.3]1,250 kg [2,756 lbs] 1276 [50.2] 586 [23.1]1,328 kg [2,928 lbs] 1229 [48.4] 577 [22.7]STD ENCLOSURE, STEELL1A ENCLOSURE, STEELL2A ENCLOSURE, STEELNOTE:CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.L2A ENCLOSURE, ALUMINUML1A ENCLOSURE, ALUMINUMSTD ENCLOSURE, ALUMINUM DESIGN GUIDE FOR GENERAC INDUSTRIAL SI GENERATORS Document No. 10000046207 EdhZ>'^^hWW>z^z^dD dŚŝƐĚĞƐŝŐŶŐƵŝĚĂŶĐĞĚŽĐƵŵĞŶƚŝƐƚŽďĞƉƌŽǀŝĚĞĚƚŽƚŚĞĐŽŶƐƵůƚŝŶŐĞŶŐŝŶĞĞƌĚƵƌŝŶŐƚŚĞƉƌŽũĞĐƚĚĞƐŝŐŶƉŚĂƐĞĂŶĚ ĂŐĂŝŶĂƚƚŚĞƚŝŵĞŽĨƐƵďŵŝƚƚĂůƚŽƚŚĞĞŶŐŝŶĞĞƌĂŶĚŵĞĐŚĂŶŝĐĂůĐŽŶƚƌĂĐƚŽƌĨŽƌĂůů'ĞŶĞƌĂĐ/ŶĚƵƐƚƌŝĂůŶĂƚƵƌĂůŐĂƐ ĂŶĚƉƌŽƉĂŶĞĨƵĞůĞĚŐĞŶĞƌĂƚŽƌƐĞƚƐ͘ dŚĞĨŽůůŽǁŝŶŐƉĂŐĞƐƉƌŽǀŝĚĞŝŶĨŽƌŵĂƚŝŽŶĂŶĚĚĞƐŝŐŶďĞƐƚƉƌĂĐƚŝĐĞƐƚŚĂƚŚĂǀĞďĞĞŶĚĞŵŽŶƐƚƌĂƚĞĚƚŽŵŝŶŝŵŝnjĞŐĂƐ ƉƌĞƐƐƵƌĞŝŶƐƚĂďŝůŝƚLJĂŶĚĨůŽǁĚĞĨŝĐŝĞŶĐLJƉƌŽďůĞŵƐŝŶƚŚĞĨŝĞůĚ͘dŚĞƐĞĚĞƐŝŐŶŐƵŝĚĞůŝŶĞƐĂƌĞƚŽďĞƵƐĞĚŝŶ ĐŽŵďŝŶĂƚŝŽŶǁŝƚŚĂƉƉůŝĐĂďůĞŶĂƚŝŽŶĂůƐƚĂŶĚĂƌĚƐϭ͕ůŽĐĂůĨƵĞůŐĂƐƉŝƉŝŶŐĐŽĚĞƐ͕ĂŶĚ'ĞŶĞƌĂĐ͛Ɛ/ŶƐƚĂůůĂƚŝŽŶ'ƵŝĚĞůŝŶĞƐ ĨŽƌ^ƚĂƚŝŽŶĂƌLJ/ŶĚƵƐƚƌŝĂů'ĞŶĞƌĂƚŽƌƐ;ŽĐƵŵĞŶƚηϬϰϲϲϮϮͿ͘ ϭ͘ĞƐŝŐŶKďũĞĐƚŝǀĞƐ͗ ϭ͘ϭ͘WƌŽǀŝĚĞƚŚĞŐĞŶĞƌĂƚŽƌǁŝƚŚĂƐƚĂďůĞŐĂƐƐƵƉƉůLJƉƌĞƐƐƵƌĞŽǀĞƌǀĂƌLJŝŶŐŐĂƐĨůŽǁĚĞŵĂŶĚĐŽŶĚŝƚŝŽŶƐ͘ DĂdžŝŵƵŵŐĂƐĨůŽǁĨŽƌĂůů'ĞŶĞƌĂĐŐĞŶĞƌĂƚŽƌƐĂƌĞůŝƐƚĞĚŽŶƚŚĞƵŶŝƚŶĂŵĞƉůĂƚĞĂŶĚŐĞŶĞƌĂƚŽƌĚĂƚĂ ƐŚĞĞƚƐ͘Ϯ ϭ͘Ϯ͘dŚĞƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶĐĞŵĞĂƐƵƌĞĚĂƚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůƉƌĞƐƐƵƌĞƚĞƐƚƉŽƌƚƐŚŽƵůĚƚLJƉŝĐĂůůLJďĞůĞƐƐƚŚĂŶϮ͟ ǁĂƚĞƌĐŽůƵŵŶ;ǁ͘Đ͘ͿĨƌŽŵŶŽͲůŽĂĚƌƵŶŶŝŶŐƚŽĨƵůůͲůŽĂĚƌƵŶŶŝŶŐĐŽŶĚŝƚŝŽŶ͘ ϭ͘ϯ͘dŚĞŐĂƐƉƌĞƐƐƵƌĞŵƵƐƚƌĞŵĂŝŶĂďŽǀĞƚŚĞŵŝŶŝŵƵŵƐƉĞĐŝĨŝĞĚĨŽƌƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĂƚĂůůƚŝŵĞƐ͕ƵŶĚĞƌĂůů ŽƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͘&ĂŝůƵƌĞƚŽŵĂŝŶƚĂŝŶĂĚĞƋƵĂƚĞŐĂƐƉƌĞƐƐƵƌĞĂŶĚĨůŽǁǁŝůůƌĞƐƵůƚŝŶŽƉĞƌĂƚŝŽŶĂů ƉƌŽďůĞŵƐƐƵĐŚĂƐĞdžƚĞŶĚĞĚĐƌĂŶŬĐLJĐůĞƐ͕ŝŶĂďŝůŝƚLJƚŽĐĂƌƌLJĨƵůůůŽĂĚ͕ĂŶĚƵŶƐƚĂďůĞĞŶŐŝŶĞƐƉĞĞĚ͘ ϭ͘ϰ͘DĂŝŶƚĂŝŶĂƉƌĞƐƐƵƌĞĂŶĚĨůŽǁŵĂƌŐŝŶƚŽĂůůŽǁĨŽƌƐĞĂƐŽŶĂůƉƌĞƐƐƵƌĞǀĂƌŝĂƚŝŽŶŽŶƚŚĞƵƉƐƚƌĞĂŵŐĂƐ ƐLJƐƚĞŵ͘dŚĞĞŵĞƌŐĞŶĐLJƐLJƐƚĞŵŵƵƐƚďĞďĞĨŽƌĞƚŚĞĨĂĐŝůŝƚLJƐŚƵƚŽĨĨ͘ ϭ͘ϱ͘KƚŚĞƌĨĂĐŝůŝƚLJůŽĂĚƐŵƵƐƚďĞĨĂĐƚŽƌĞĚŝŶǁŚŝůĞƐŝnjŝŶŐƚŚĞ'ĞŶĞƌĂƚŽƌĨƵĞůƐLJƐƚĞŵ͘/ƚŝƐƌĞĐŽŵŵĞŶĚĞĚƚŚĂƚ ƚŚĞŐĞŶĞƌĂƚŽƌƐŚŽƵůĚŚĂǀĞĂĚĞĚŝĐĂƚĞĚĨƵĞůƐƵƉƉůLJ͕ǁŚŝĐŚŝƐŶŽƚƐŚĂƌĞĚǁŝƚŚĂŶLJŽƚŚĞƌĂƉƉůŝĂŶĐĞƐ ;ĨƵƌŶĂĐĞ͕ǁĂƚĞƌŚĞĂƚĞƌƐ͕ƌĂŶŐĞƐ͕ĞƚĐ͘ͿĂŶĚƚŚĞ'ĞŶĞƌĂƚŽƌĨƵĞůƐƵƉƉůLJůŝŶĞƐŚĂůůďĞŝŶƐƚĂůůĞĚĂǁĂLJĨƌŽŵĂ ŚŝŐŚŚĞĂƚƐŽƵƌĐĞƐŽƚŚĂƚƚŚĞĨƵĞůƚĞŵƉĞƌĂƚƵƌĞŵƵƐƚƌĞŵĂŝŶĂƚĂŶĂĐĐĞƉƚĂďůĞŽƉĞƌĂƚŝŶŐƌĂŐĞ͘ &ŝŐƵƌĞϭ͗dLJƉŝĐĂůŶĂƚƵƌĂůŐĂƐƐƵƉƉůLJƌĞŐƵůĂƚŽƌĂŶĚƉŝƉŝŶŐĐŽŶĨŝŐƵƌĂƚŝŽŶ͘ Ϯ͘ZĞŐƵůĂƚŽƌWĞƌĨŽƌŵĂŶĐĞƚƚƌŝďƵƚĞƐϯ͗ Ϯ͘ϭ͘ZĞŐƵůĂƚŽƌŽĚLJ^ŝnjĞ͗dŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŽƌƚƐŽŶĂƌĞŐƵůĂƚŽƌĂƌĞƚLJƉŝĐĂůůLJĂƐŝŶŐůĞŵĞƚĂůĐĂƐƚŝŶŐ͘dŚĞ ͞ďŽĚLJƐŝnjĞ͟ƌĞĨĞƌƐƚŽƚŚĞŶŽŵŝŶĂůĚŝĂŵĞƚĞƌŽĨƚŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŝƉĞƚŚƌĞĂĚƐ;ŽƌĨůĂŶŐĞͿ͘dŚĞƌĞŐƵůĂƚŽƌ ďŽĚLJƐŝnjĞƐŚŽƵůĚŶĞǀĞƌďĞůĂƌŐĞƌƚŚĂŶƚŚĞƉŝƉĞƐŝnjĞ͕ďƵƚŝƚŵĂLJďĞƐŵĂůůĞƌƉƌŽǀŝĚĞĚƚŚĞƌĞƋƵŝƌĞĚĨůŽǁĐĂŶ ďĞŽďƚĂŝŶĞĚƚŚƌŽƵŐŚƚŚĞƐŵĂůůĞƌƌĞŐƵůĂƚŽƌďŽĚLJƐŝnjĞ͘ Ϯ͘Ϯ͘WƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶƚŝĂů͗dŚĞŵĂdžŝŵƵŵĨůŽǁƌĂƚĞŽĨĂƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌŝƐĐŽŶƐƚƌĂŝŶĞĚďLJƚŚĞŐĂƐƉƌĞƐƐƵƌĞ ĚŝĨĨĞƌĞŶƚŝĂůĂĐƌŽƐƐƚŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŽƌƚ͘tŚĞŶƐĞůĞĐƚŝŶŐĂƌĞŐƵůĂƚŽƌĨŽƌĂƐƉĞĐŝĨŝĐŐĂƐĨůŽǁ ƌĞƋƵŝƌĞŵĞŶƚ͕ŝƚŵƵƐƚĐŽƌƌĞƐƉŽŶĚƚŽƚŚĞĞdžƉĞĐƚĞĚŶŽŵŝŶĂůƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞƐ͘ ŽŶƐƵůƚŵĂŶƵĨĂĐƚƵƌĞƌƐ͛ƉƵďůŝƐŚĞĚĨůŽǁƌĂƚĞƚĂďůĞƐĂƚǀĂƌŝŽƵƐŝŶůĞƚĂŶĚŽƵƚůĞƚƉƌĞƐƐƵƌĞǀĂůƵĞƐƚŽƐĞůĞĐƚĂŶ ĂƉƉƌŽƉƌŝĂƚĞƌĞŐƵůĂƚŽƌ;^ĞĞƚŚĞĞdžĂŵƉůĞŝŶ&ŝŐƵƌĞϮͿ͘ Ϯ͘ϯ͘&ůŽǁĂŶĚĚƌŽŽƉ͗^ĞůĞĐƚĂĚŝƌĞĐƚĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƚŚĂƚǁŝůůĚĞůŝǀĞƌĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵ ŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌǁŝƚŚϭ͟ʹϮ͟ǁĂƚĞƌĐŽůƵŵŶ;ǁ͘Đ͘ͿƉƌĞƐƐƵƌĞĚƌŽŽƉĂƚƚŚĞĞdžƉĞĐƚĞĚ ŶŽŵŝŶĂůƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞƐ͘ŝƌĞĐƚĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƐƉƌŽǀŝĚĞƚŚĞƋƵŝĐŬƌĞƐƉŽŶƐĞ ƌĞƋƵŝƌĞĚĨŽƌĐŽŶƚƌŽůůŝŶŐĨĂƐƚĐŚĂŶŐŝŶŐŐĂƐĨůŽǁĚĞŵĂŶĚƐĞŶĐŽƵŶƚĞƌĞĚŝŶĞŶŐŝŶĞͲŐĞŶĞƌĂƚŽƌĂƉƉůŝĐĂƚŝŽŶƐ͘ &ŽƌĞdžĂŵƉůĞ͕Ă'ĞŶĞƌĂĐ^'ϱϬϬŐĞŶĞƌĂƚŽƌ͕ĐŽŶĨŝŐƵƌĞĚĨŽƌϳ͟Ͳϭϭ͟ǁ͘Đ͘ŶŽŵŝŶĂůŐĂƐƉƌĞƐƐƵƌĞ͕ƌĞƋƵŝƌĞƐϲ͕ϬϬϬ &,ŽĨŐĂƐĂƚĨƵůůůŽĂĚ͘dŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌŵƵƐƚďĞƌĂƚĞĚƚŽĨůŽǁĂƉƉƌŽdžŝŵĂƚĞůLJϵ͕ϬϬϬ&,;ϭ͘ϱyϲϬϬϬ &,сϵϬϬϬ&,Ϳ͘'ŝǀĞŶĂŶƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŽĨϮƉƐŝ͕ĂϭͲϭͬϮ͟DŽĚĞůϭϮϮͲϭϮƌĞŐƵůĂƚŽƌǁŝƚŚĂďůƵĞ ƐƉƌŝŶŐǁŽƵůĚďĞƚŚĞĨŝƌƐƚĐŚŽŝĐĞ͘,ŽǁĞǀĞƌ͕ĂƐƐƵŵĞƚŚĞƌĞŝƐĂƐƵďƐƚĂŶƚŝĂůƌŝƐŬŽĨƐĞĂƐŽŶĂůƉƌĞƐƐƵƌĞ ǀĂƌŝĂƚŝŽŶǁŚĞƌĞƚŚĞƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŵĂLJĨĂůůĐůŽƐĞƌƚŽϭƉƐŝ͕ĂůĂƌŐĞƌϮ͟DŽĚĞůϭϮϮͲϭϮƌĞŐƵůĂƚŽƌ ǁŝƚŚĂďůƵĞƐƉƌŝŶŐǁŝůůƐƚŝůůƉƌŽǀŝĚĞƚŚĞƌĞƋƵŝƌĞĚĨůŽǁĂƚƚŚĞůŽǁĞƌƵƉƐƚƌĞĂŵƉƌĞƐƐƵƌĞ͘ &ŝŐƵƌĞϮ͗dLJƉŝĐĂůƌĞŐƵůĂƚŽƌĨůŽǁĐĂƉĂĐŝƚLJƚĂďůĞ͘EŽƚĞŚŽǁƚŚĞƐĂŵĞŵŽĚĞůƌĞŐƵůĂƚŽƌǁŝůůĨůŽǁůĂƌŐĞƌǀŽůƵŵĞƐ ŽĨŐĂƐǁŝƚŚĂŚŝŐŚĞƌŝŶůĞƚƉƌĞƐƐƵƌĞǁŚŝůĞŵĂŝŶƚĂŝŶŝŶŐĂƐĞƚĚŽǁŶƐƚƌĞĂŵƉƌĞƐƐƵƌĞ͘ŽƵƌƚĞƐLJŽĨ^ĞŶƐƵƐ͘ 'ĂƐƉƌĞƐƐƵƌĞƌĞŐƵůĂƚŽƌƐĂƌĞĨĞĞĚďĂĐŬĐŽŶƚƌŽůƐLJƐƚĞŵƐĚƌŝǀĞŶďLJƚŚĞƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶƚŝĂůĂĐƌŽƐƐƚŚĞ ĚŝĂƉŚƌĂŐŵĂŶĚƚŚĞĐĂƐĞƐƉƌŝŶŐ͘tŚĞŶŐĂƐĨůŽǁŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌĐĂƵƐĞƐĂ ƉƌĞƐƐƵƌĞĚƌŽƉ͕ƐƉƌŝŶŐĨŽƌĐĞŝŶƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞƉƵƐŚĞƐŽŶƚŚĞĚŝĂƉŚƌĂŐŵĂŶĚŽƉĞŶƐƚŚĞǀĂůǀĞƚŽ ŝŶĐƌĞĂƐĞŐĂƐĨůŽǁƚŽŵĂŝŶƚĂŝŶƚŚĞƐĞƚƉƌĞƐƐƵƌĞ͘dŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞŵĂŝŶƚĂŝŶĞĚďLJƚŚĞƌĞŐƵůĂƚŽƌ ĚĞĐƌĞĂƐĞƐƐůŝŐŚƚůLJĂƐŐĂƐĨůŽǁƌĂƚĞŝŶĐƌĞĂƐĞƐ;&ŝŐƵƌĞϯͿ͘dŚŝƐƉŚĞŶŽŵĞŶŽŶŝƐŬŶŽǁŶĂƐƉƌĞƐƐƵƌĞĚƌŽŽƉŽƌ͕ ŵŽƌĞƐŝŵƉůLJ͕͞ĚƌŽŽƉ͘͟ZĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌƐĚĞƐŝŐŶƉƌŽĚƵĐƚƐƚŽŵŝŶŝŵŝnjĞƉƌĞƐƐƵƌĞĚƌŽŽƉǁŚŝůĞƐƚŝůů ŵĂŝŶƚĂŝŶŝŶŐƌĞŐƵůĂƚŽƌƐƚĂďŝůŝƚLJĨŽƌĂŐŝǀĞŶŐĂƐĨůŽǁƌĂƚĞ͘ ZĞŐƵůĂƚŽƌƐƚĞŶĚƚŽĞdžŚŝďŝƚƚŚĞďĞƐƚƐƚĂďŝůŝƚLJĂŶĚƌĞƐƉŽŶƐĞƚŝŵĞǁŚĞŶƚŚĞLJŽƉĞƌĂƚĞŶĞĂƌƚŚĞŵŝĚĚůĞŽĨ ƚŚĞŝƌƉƌŽƉŽƌƚŝŽŶĂůďĂŶĚ͘^ĞůĞĐƚŝŶŐĂƌĞŐƵůĂƚŽƌǁŝƚŚĂƉƵďůŝƐŚĞĚŵĂdžŝŵƵŵŐĂƐĨůŽǁŽĨĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱ ƚŝŵĞƐƚŚĞĨƵůůͲůŽĂĚŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌĂǀŽŝĚƐŽƉĞƌĂƚŝŽŶǀĞƌLJĐůŽƐĞƚŽƚŚĞĨƵůůLJŽƉĞŶŽƌ ĨƵůůLJĐůŽƐĞĚƉŽƐŝƚŝŽŶ͕ŵŝŶŝŵŝnjŝŶŐƚŚĞƉƌŽďĂďŝůŝƚLJŽĨƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ƌĞŐƵůĂƚŽƌƚŚĂƚŝƐƚŽŽůĂƌŐĞ͕ ĐĂƉĂďůĞŽĨĨůŽǁŝŶŐƐĞǀĞƌĂůƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌ͕ǁŝůůŽƉĞƌĂƚĞǀĞƌLJ ĐůŽƐĞƚŽŝƚƐĨƵůůLJĐůŽƐĞĚƉŽƐŝƚŝŽŶǁŚŝĐŚŵĂLJĂůƐŽƌĞƐƵůƚŝŶƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ &ŝŐƵƌĞϯ͗WƌĞƐƐƵƌĞĚƌŽŽƉĐŚĂƌĂĐƚĞƌŝƐƚŝĐŽĨĂƚLJƉŝĐĂůĚŝƌĞĐƚͲŽƉĞƌĂƚĞĚƌĞŐƵůĂƚŽƌ͘ ŽƵƌƚĞƐLJŽĨŵĞƌƐŽŶͲ&ŝƐŚĞƌEĂƚƵƌĂů'ĂƐƉƉůŝĐĂƚŝŽŶ'ƵŝĚĞ͘ Ϯ͘ϰ͘^ƉƌŝŶŐZĂƚĞ͕ĐĐƵƌĂĐLJ͕ĂŶĚZĞƐƉŽŶƐĞdŝŵĞϰ͗dŚĞƌĞŐƵůĂƚŽƌƐƉƌŝŶŐƉƌŽǀŝĚĞƐƚŚĞĨŽƌĐĞƌĞƋƵŝƌĞĚƚŽŽƉĞŶ ƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞĂŶĚŵĂŝŶƚĂŝŶƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͘dŚĞƌĞŵĂLJďĞŵŽƌĞƚŚĂŶŽŶĞƐƉƌŝŶŐ ĐŽǀĞƌŝŶŐĂĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͘^ƉƌŝŶŐƐĞůĞĐƚŝŽŶƉůĂLJƐĂƌŽůĞŝŶƌĞŐƵůĂƚŽƌĂĐĐƵƌĂĐLJĂŶĚƌĞƐƉŽŶƐĞ ƚŝŵĞ͘ /ŶŐĞŶĞƌĂů͕ƵƐŝŶŐƚŚĞůŝŐŚƚĞƐƚƐƉƌŝŶŐƌĂƚĞ;ĂďůƵĞƐƉƌŝŶŐĨƌŽŵƚŚĞƉƌŝŽƌĞdžĂŵƉůĞƌĞĨĞƌĞŶĐŝŶŐ&ŝŐƵƌĞϮͿƚŚĂƚ ĂĐŚŝĞǀĞƐƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞǁŝůůƉƌŽǀŝĚĞƚŚĞďĞƐƚĂĐĐƵƌĂĐLJ͕ŵŝŶŝŵŝnjŝŶŐƉƌĞƐƐƵƌĞĚƌŽŽƉĂĐƌŽƐƐ ƚŚĞƌĂŶŐĞŽĨĞdžƉĞĐƚĞĚŐĂƐĨůŽǁƌĂƚĞƐ͘,ŽǁĞǀĞƌ͕ĂƌĞƐƉŽŶƐĞƚŚĂƚŝƐ͞ƚŽŽĨĂƐƚ͟ĐĂŶŝŶƚƌŽĚƵĐĞŽƐĐŝůůĂƚŝŽŶĂŶĚ ŝŶƐƚĂďŝůŝƚLJ͘/ĨŝŶƐƚĂďŝůŝƚLJŝƐĞdžƉĞƌŝĞŶĐĞĚĚƵƌŝŶŐŽƉĞƌĂƚŝŽŶ͕ŵŽǀŝŶŐƚŽƚŚĞŶĞdžƚŚŝŐŚĞƌƐƉƌŝŶŐ;ĂŐƌĞĞŶƐƉƌŝŶŐ ĨƌŽŵƚŚĞƉƌŝŽƌĞdžĂŵƉůĞƌĞĨĞƌĞŶĐŝŶŐ&ŝŐƵƌĞϮͿƚŚĂƚŝŶĐůƵĚĞƐƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞŝƐŽŶĞƉŽƚĞŶƚŝĂů ŵĞƚŚŽĚƚŽŵŝƚŝŐĂƚĞŽƐĐŝůůĂƚŝŽŶƐ Ϯ͘ϱ͘KƌŝĨŝĐĞƐŝnjĞ͗&ŽƌƌĞŐƵůĂƚŽƌƐǁŚĞƌĞǀĂƌŝŽƵƐŽƌŝĨŝĐĞƐŝnjĞƐĂƌĞĂǀĂŝůĂďůĞ͕ƐĞůĞĐƚƚŚĞƐŵĂůůĞƐƚŽƌŝĨŝĐĞƚŚĂƚǁŝůů ƉƌŽǀŝĚĞĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌ͘^ĞůĞĐƚŝŶŐĂŶŽƌŝĨŝĐĞ ƚŚĂƚŝƐƐŝŐŶŝĨŝĐĂŶƚůLJůĂƌŐĞƌƚŚĂŶŶĞĐĞƐƐĂƌLJǁŝůůƌĞƐƵůƚŝŶƚŚĞǀĂůǀĞŽƉĞƌĂƚŝŶŐǀĞƌLJĐůŽƐĞƚŽƚŚĞƐĞĂƚ;ŶĞĂƌůLJ ĐůŽƐĞĚͿĂŶĚŵĂLJƌĞƐƵůƚŝŶƉƌĞƐƐƵƌĞŝŶƐƚĂďŝůŝƚLJ͕ŝŶĐƌĞĂƐĞĚƐĞĂůǁĞĂƌ͕ŽƌĂƵĚŝďůĞŶŽŝƐĞĨƌŽŵƚŚĞƌĞŐƵůĂƚŽƌ͘ Ϯ͘ϲ͘>ŽĐŬƵƉŽƌŚĂƌĚƐŚƵƚŽĨĨ͗ƌĞŐƵůĂƚŽƌǁŝƚŚĂůŽĐŬƵƉŽƌŚĂƌĚƐŚƵƚŽĨĨĨĞĂƚƵƌĞŵƵƐƚďĞƵƐĞĚ͘>ŽĐŬƵƉŝƐƚŚĞ ƉƌĞƐƐƵƌĞĂďŽǀĞƚŚĞƌĞŐƵůĂƚŽƌƐĞƚƉŽŝŶƚƚŚĂƚŝƐƌĞƋƵŝƌĞĚƚŽƐŚƵƚƚŚĞƌĞŐƵůĂƚŽƌŽĨĨƚŝŐŚƚƐŽŶŽŐĂƐĨůŽǁƐ͘ dLJƉŝĐĂůůLJ͕ƚŚĞůŽĐŬƵƉƉƌĞƐƐƵƌĞŝƐϭ͟Ͳϯ͟t͘͘ĂďŽǀĞƚŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞƐĞƚƉŽŝŶƚŵĞĂƐƵƌĞĚǁŚĞŶĂƐŵĂůů ǀŽůƵŵĞŽĨŐĂƐŝƐĨůŽǁŝŶŐ;ŝ͘Ğ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐĐŽŶĚŝƚŝŽŶŽŶƚŚĞŐĞŶĞƌĂƚŽƌͿ͘dŚĞůŽĐŬƵƉĨĞĂƚƵƌĞƉƌĞǀĞŶƚƐ ƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌĨƌŽŵĐƌĞĞƉŝŶŐƵƉƚŽƚŚĞƌĞŐƵůĂƚŽƌůŝŶĞƐŝĚĞƉƌĞƐƐƵƌĞĚƵƌŝŶŐůŽŶŐ ƉĞƌŝŽĚƐŽĨnjĞƌŽŐĂƐĨůŽǁǁŚĞŶƚŚĞŐĞŶĞƌĂƚŽƌŝƐŶŽƚƌƵŶŶŝŶŐ͘/ĨĞdžĐĞƐƐŝǀĞŐĂƐƉƌĞƐƐƵƌĞŝƐĂůůŽǁĞĚƚŽďƵŝůĚ ƵƉŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͕ƚŚĞŐĞŶĞƌĂƚŽƌƐŽůĞŶŽŝĚǀĂůǀĞƐŵĂLJďĞƵŶĂďůĞƚŽŽƉĞŶ ĂŐĂŝŶƐƚƚŚĞĞdžĐĞƐƐŝǀĞƉƌĞƐƐƵƌĞĂŶĚƚŚĞĞŶŐŝŶĞǁŝůůŶŽƚƐƚĂƌƚ͘ Ϯ͘ϳ͘/ŶƚĞƌŶĂůǀƐ͘ĞdžƚĞƌŶĂůƉƌĞƐƐƵƌĞƌĞŐŝƐƚƌĂƚŝŽŶ͗/ŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐĂƌĞƌĞĐŽŵŵĞŶĚĞĚďĞĐĂƵƐĞ ƚŚĞLJŐĞŶĞƌĂůůLJŚĂǀĞĨĞǁĞƌŽƉĞƌĂƚŝŽŶĂůƉƌŽďůĞŵƐŝŶƚŚĞĨŝĞůĚ͘ &ŝŐƵƌĞϰ͗DĂũŽƌĐŽŵƉŽŶĞŶƚƐŽĨĂĚŝƌĞĐƚͲĂĐƚŝŶŐůĞǀĞƌͲƚLJƉĞƌĞŐƵůĂƚŽƌ͕ ŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚ͘ŽƵƌƚĞƐLJŵĞƌƐŽŶ&ŝƐŚĞƌ͘ dŚĞĚŝĂƉŚƌĂŐŵĐĂƐĞŽĨĂƌĞŐƵůĂƚŽƌŵƵƐƚŚĂǀĞĂĐŽŶŶĞĐƚŝŽŶƚŽƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŝŶŽƌĚĞƌƚŽĨƵŶĐƚŝŽŶ͘ /ŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐŚĂǀĞĂƉĂƐƐĂŐĞďƵŝůƚŝŶƚŽƚŚĞďŽĚLJĐĂƐƚŝŶŐǁŚŝĐŚƉƌŽǀŝĚĞƐĂƉĂƚŚĨŽƌůŽǁͲ ƉƌĞƐƐƵƌĞŐĂƐƚŽĂĐƚĂŐĂŝŶƐƚƚŚĞĚŝĂƉŚƌĂŐŵĂŶĚƐƉƌŝŶŐĨŽƌĐĞ͘džƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐůĂĐŬƚŚŝƐ ŝŶƚĞƌŶĂůĐŽŶŶĞĐƚŝŽŶƉĂƚŚďƵƚŝŶƐƚĞĂĚŚĂǀĞĂŶĂĚĚŝƚŝŽŶĂůƉŝƉĞĨŝƚƚŝŶŐŽŶƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞǁŚĞƌĞĂƐŵĂůůĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŝƐĨŝĞůĚͲĨĂďƌŝĐĂƚĞĚƚŽĂĚŽǁŶƐƚƌĞĂŵůŽĐĂƚŝŽŶŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞŵĂŝŶŐĂƐ ƉŝƉŝŶŐƐLJƐƚĞŵ͘ĞĐĂƵƐĞĂůůƚŚĞƉŝƉĞĨĂďƌŝĐĂƚŝŽŶŝƐĚŽŶĞŝŶƚŚĞĨŝĞůĚ͕ǀĂƌŝĂƚŝŽŶŝŶƚŚĞŵĂŝŶŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵ ĂŶĚƚŚĞƌĞŵŽƚĞƉƌĞƐƐƵƌĞƌĞŐŝƐƚƌĂƚŝŽŶůŝŶĞĐĂŶĐĂƵƐĞƵŶƉƌĞĚŝĐƚĂďůĞƉĞƌĨŽƌŵĂŶĐĞƚŚĂƚŝƐĚŝĨĨŝĐƵůƚƚŽ ƚƌŽƵďůĞƐŚŽŽƚ͘ džƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐĐĂŶďĞƵƐĞĚ͕ďƵƚƚŚĞĞŶŐŝŶĞĞƌĂŶĚŝŶƐƚĂůůĂƚŝŽŶĐŽŶƚƌĂĐƚŽƌŵƵƐƚďĞĂǁĂƌĞ ŽĨƚŚĞĚLJŶĂŵŝĐĞĨĨĞĐƚƐŝŶƚƌŽĚƵĐĞĚďLJǀĂƌŝĂďůĞƐƐƵĐŚĂƐ͖ĨůŽǁƚƵƌďƵůĞŶĐĞ͕ůĞŶŐƚŚĂŶĚĚŝĂŵĞƚĞƌŽĨƚŚĞ ƐĞŶƐŝŶŐůŝŶĞ͕ůŽĐĂƚŝŽŶŽĨƚŚĞƐĞŶƐŝŶŐƉŽŝŶƚŝŶƚŚĞůŽǁƉƌĞƐƐƵƌĞƉŝƉŝŶŐƐLJƐƚĞŵ͕ŝŶĐƌĞĂƐĞƐĂŶĚĚĞĐƌĞĂƐĞƐŝŶ ƉŝƉĞĚŝĂŵĞƚĞƌ͘ /ĨĂŶĞdžƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ůŽĐĂƚĞƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐƉŽŝŶƚϴƚŽϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐ ĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌŝŶƚŚĞůĂƌŐĞƐƚĚŝĂŵĞƚĞƌƉŝƉĞƐĞĐƚŝŽŶ͘dŚĞƐƚĂƌƚŽĨϴƚŽϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐŝƐ ĂĨƚĞƌƚŚĞƚƌĂŶƐŝƚŝŽŶƚŽƚŚĞůĂƌŐĞƐƚĚŝĂŵĞƚĞƌƉŝƉĞŽƌĂŶLJŽƚŚĞƌƚŚƌŽƚƚůŝŶŐĚĞǀŝĐĞƐ͕ĐŽŵƉŽŶĞŶƚĂŶĚͬŽƌĨŝƚƚŝŶŐƐ ƚŚĂƚǁŝůůĚŝƐƌƵƉƚĨůŽǁĂŶĚĐƌĞĂƚĞƚƵƌďƵůĞŶĐĞ͘dŚĞƐĞŶƐŝŶŐůŝŶĞƐŚŽƵůĚďĞƚĂŬĞŶŽĨĨƚŚĞƚŽƉŽĨƚŚĞŵĂŝŶůŝŶĞ ƚŽŬĞĞƉŝƚĨƌĞĞŽĨĚĞďƌŝƐĂŶĚĐŽŶĚĞŶƐĂƚĞ͘/ĨƉŽƐƐŝďůĞ͕ŝƚƐŚŽƵůĚŚŽƌŝnjŽŶƚĂůůLJƐůŽƉĞďĂĐŬƚŽƚŚĞŵĂŝŶƐŽƚŚĂƚ ĂŶLJĐŽŶĚĞŶƐĂƚĞǁŝůůĚƌĂŝŶďĂĐŬŝŶƚŽƚŚĞŵĂŝŶƌĂƚŚĞƌƚŚĂŶĂĐĐƵŵƵůĂƚĞŝŶƚŚĞƌĞŐƵůĂƚŽƌΖƐĚŝĂƉŚƌĂŐŵĐĂƐĞ͘ DŝŶŝŵŝnjĞƚŚĞĨŝƚƚŝŶŐƐƵƐĞĚŝŶƌƵŶŶŝŶŐƚŚĞƐĞŶƐŝŶŐůŝŶĞ͘ŶĞdžƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌǁŝůůƌĞƐƉŽŶĚƚŽ ƚŚĞƉƌĞƐƐƵƌĞĐŚĂŶŐĞƐƐĞŶƐĞĚĂƚƚŚĞƌĞŵŽƚĞƚĂƉƌĂƚŚĞƌƚŚĂŶǁŝƚŚŝŶƚŚĞƌĞŐƵůĂƚŽƌďŽĚLJ͘/ƚŝƐĂĚǀŝƐĂďůĞƚŽ ŝŶƐƚĂůůĂƉƌĞƐƐƵƌĞŐĂƵŐĞĂƚƚŚĞƐĞŶƐŝŶŐůŝŶĞƚĂƉŽŶƚŚĞŵĂŝŶĂƐƚŚŝƐǁŝůůďĞƚŚĞĐŽŶƚƌŽůƉŽŝŶƚŽĨƚŚĞ ƌĞŐƵůĂƚŽƌ͘ Ϯ͘ϴ͘ZĞĐŽŵŵĞŶĚĞĚŐĂƐƌĞŐƵůĂƚŽƌƐ͗ dŚĞůŝƐƚŽĨƌĞŐƵůĂƚŽƌƐďĞůŽǁŝƐŶŽƚĂŶĞdžŚĂƵƐƚŝǀĞůŝƐƚŽĨĂůůƐƵŝƚĂďůĞƌĞŐƵůĂƚŽƌƐƚŚĂƚĂƌĞĂǀĂŝůĂďůĞŝŶƚŚĞ ŵĂƌŬĞƚ͕ŶŽƌŝƐŝƚĂůŝƐƚŽĨ͞'ĞŶĞƌĂĐƉƉƌŽǀĞĚ͟ƌĞŐƵůĂƚŽƌƐ͘dŚĞůŝƐƚŝƐŝŶƚĞŶĚĞĚƚŽŚĞůƉĚĞƐŝŐŶĞŶŐŝŶĞĞƌƐĂŶĚ ŵĞĐŚĂŶŝĐĂůĐŽŶƚƌĂĐƚŽƌƐŝĚĞŶƚŝĨLJĂƌĂŶŐĞŽĨƉƌŽĚƵĐƚƐƚŚĂƚŚĂǀĞĚĞŵŽŶƐƚƌĂƚĞĚƚŚĞŝƌƐƵŝƚĂďŝůŝƚLJĨŽƌĞŶŐŝŶĞͲ ŐĞŶĞƌĂƚŽƌƐĞƌǀŝĐĞŝŶƉĂƐƚƉƌŽũĞĐƚƐ͘ŽŶƐƵůƚLJŽƵƌ'ĞŶĞƌĂĐŝƐƚƌŝďƵƚŽƌŽƌŐĂƐƌĞŐƵůĂƚŽƌƐƵƉƉůŝĞƌĨŽƌ ĂĚĚŝƚŝŽŶĂůŝŶĨŽƌŵĂƚŝŽŶ͘ Ͳ^ĞŶƐƵƐϱ ͲŵĞƌƐŽŶ&ŝƐŚĞƌ Ͳ/ƚƌŽŶ ϯ͘&ůŽǁŚĂƌĂĐƚĞƌŝƐƚŝĐƐŽĨ'ĂƐWŝƉŝŶŐ^LJƐƚĞŵƐ͗ ϯ͘ϭ͘ůďŽǁƐĂŶĚdĞĞƐ͗DŝŶŝŵŝnjĞƚŚĞŶƵŵďĞƌŽĨĞůďŽǁƐĂŶĚƚĞĞĨŝƚƚŝŶŐƐƚŚĂƚŝŶĐƌĞĂƐĞƉƌĞƐƐƵƌĞĚƌŽƉĂŶĚĨůŽǁ ƚƵƌďƵůĞŶĐĞŝŶƚŚĞƐLJƐƚĞŵ͘tŚĞƌĞŵŽƌĞƚŚĂŶƚŚƌĞĞĞůďŽǁƐĂŶĚͬŽƌƚĞĞƐĂƌĞƌĞƋƵŝƌĞĚ͕ƵƐĞŽĨƐǁĞƉƚƌĂĚŝƵƐ ĞůďŽǁƐ;ƚLJƉŝĐĂůĨŽƌǁĞůĚĞĚƉŝƉĞƐĞĐƚŝŽŶƐͿǁŝůůŚĞůƉƌĞĚƵĐĞƉƌĞƐƐƵƌĞůŽƐƐ͘ ϯ͘Ϯ͘ZĞĚƵĐŝŶŐďƵƐŚŝŶŐƐ;ƐǁĂŐĞƐͿ͗WŝƉĞƌĞĚƵĐŝŶŐďƵƐŚŝŶŐƐĂƌĞƚŚĞƚƌĂŶƐŝƚŝŽŶĨƌŽŵĂůĂƌŐĞƌƚŽƐŵĂůůĞƌƉŝƉĞ ĚŝĂŵĞƚĞƌŽƌǀŝĐĞǀĞƌƐĂ͘'ĂƐĨůŽǁǀĞůŽĐŝƚLJŝƐƐůŽǁĞƌŝŶĂůĂƌŐĞƌĚŝĂŵĞƚĞƌƉŝƉĞĐŽŵƉĂƌĞĚƚŽĂƐŵĂůůĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŵŽǀŝŶŐƚŚĞƐĂŵĞǀŽůƵŵĞŽĨŐĂƐ͘/ĨĂƌĞŵŽƚĞƐĞŶƐŝŶŐƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ŝƚŝƐŝŵƉŽƌƚĂŶƚƚŽ ƵŶĚĞƌƐƚĂŶĚƚŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞĞĨĨĞĐƚƐĐĂƵƐĞĚďLJƚŚĞŐĂƐĨůŽǁǀĞůŽĐŝƚŝĞƐŝŶĚŝĨĨĞƌĞŶƚƐŝnjĞĚƉŝƉĞƐĞĐƚŝŽŶƐ ĂŶĚĚĞƐŝŐŶĂĐĐŽƌĚŝŶŐůLJ͘ϲ /ŶƐŽŵĞŝŶƐƚĂůůĂƚŝŽŶƐǁŚĞƌĞŝƚŝƐŝŵƉƌĂĐƚŝĐĂůƚŽƌƵŶĂƉƉƌŽdžŝŵĂƚĞůLJϭϬĨĞĞƚŽĨƉŝƉĞ͕ƐǁĂŐŝŶŐƵƉƚŽĂůĂƌŐĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŝƐĂƉƌĂĐƚŝĐĂůŵĞƚŚŽĚƚŽŝŶĐƌĞĂƐĞƚŚĞŐĂƐǀŽůƵŵĞďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůƐLJƐƚĞŵ͘&ŽƌŝŶƐƚĂůůĂƚŝŽŶƐǁŚĞƌĞƚŚŝƐŵĞƚŚŽĚŝƐƵƐĞĚ͕ĂŶŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐ ƐƚƌŽŶŐůLJƌĞĐŽŵŵĞŶĚĞĚ͘ ϯ͘ϯ͘&ůĞdžŝďůĞĨƵĞůůŝŶĞƐ͗&ůĞdžŝďůĞĨƵĞůůŝŶĞƐĂƌĞŝŶƚĞŶĚĞĚƚŽŝƐŽůĂƚĞƚŚĞƌŝŐŝĚŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵĨƌŽŵǀŝďƌĂƚŝŽŶƐŽŶ ƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĂŶĚŵƵƐƚďĞŝŶƐƚĂůůĞĚĂƐƐƚƌĂŝŐŚƚĂƐƉŽƐƐŝďůĞ͘dŚĞLJĂƌĞŶŽƚŝŶƚĞŶĚĞĚƚŽĐŽƌƌĞĐƚ ŵŝƐĂůŝŐŶĞĚƉŝƉĞƐĞĐƚŝŽŶƐŽƌƚŽƐĞƌǀĞĂƐĂŶĞůďŽǁ͘ ϯ͘ϰ͘ZĞŐƵůĂƚŽƌǀĞŶƚůŝŶĞƐ͗ZĞŐƵůĂƚŽƌǀĞŶƚƐŵƵƐƚŽƉĞŶĚŽǁŶǁĂƌĚĂŶĚďĞƐĐƌĞĞŶĞĚƚŽƉƌĞǀĞŶƚŝŶƐĞĐƚƐĂŶĚ ǁĂƚĞƌĨƌŽŵĞŶƚĞƌŝŶŐƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞ͘ZĞŐƵůĂƚŽƌǀĞŶƚůŝŶĞƐƐŚŽƵůĚďĞŬĞƉƚĂƐƐŚŽƌƚĂƐƉŽƐƐŝďůĞƚŽƌĞĚƵĐĞ ƚŚĞƉŽƐƐŝďŝůŝƚLJŽĨĂĨĨĞĐƚŝŶŐƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞƚŝŵĞ͘ ϰ͘ĞƐŝŐŶZĞƋƵŝƌĞŵĞŶƚƐ͗ ϰ͘ϭ͘hƐĞ'ĞŶĞƌĂĐ͛ƐWŽǁĞƌĞƐŝŐŶWƌŽϳŐĂƐƉŝƉĞƐŝnjŝŶŐŵŽĚƵůĞƚŽĚĞƚĞƌŵŝŶĞƚŚĞŵŝŶŝŵƵŵƌĞĐŽŵŵĞŶĚĞĚƉŝƉĞ ƐŝnjĞĨŽƌƚŚĞƐĞůĞĐƚĞĚŐĞŶĞƌĂƚŽƌ͛ƐŐĂƐĨůŽǁŐŝǀĞŶƚŚĞĂŶƚŝĐŝƉĂƚĞĚůĞŶŐƚŚŽĨƚŚĞƉŝƉĞƌƵŶďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞ ƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚ͕ŝŶĐůƵĚŝŶŐĂůůĞůďŽǁƐ͘^ĞůĞĐƚƚŚĞŽƉƚŝŽŶƚŽĚĞƐŝŐŶĨŽƌфϬ͘ϱ͟ǁĂƚĞƌ ĐŽůƵŵŶƉƌĞƐƐƵƌĞĚƌŽƉ͘ZĞĨĞƌƚŽƚŚĞdĂďůĞϭĨŽƌŵŽƌĞĚĞƚĂŝů͘ ϰ͘Ϯ͘dŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞƐŚĂůůďĞŝŶƐƚĂůůĞĚĂƚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚůŽĐĂƚĞĚŽŶƚŚĞĨƌĂŵĞƌĂŝůĂŶĚŵƵƐƚĞdžŝƚ ƚŚĞŐĞŶĞƌĂƚŽƌƉĞƌƉĞŶĚŝĐƵůĂƌƚŽƚŚĞĨƌĂŵĞƌĂŝů͘EŽƉŝƉĞĨŝƚƚŝŶŐƐ;ĞůďŽǁƐŽƌƐǁĂŐĞƐͿĂƌĞƉĞƌŵŝƚƚĞĚďĞƚǁĞĞŶ ƚŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚƉŽƌƚ͘ ϰ͘ϯ͘dŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞŵƵƐƚďĞĂƐƐƚƌĂŝŐŚƚĂƐƉŽƐƐŝďůĞ͘/ƚŝƐĚĞƐŝŐŶĞĚƚŽŝƐŽůĂƚĞƚŚĞƌŝŐŝĚŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵ ĨƌŽŵǀŝďƌĂƚŝŽŶƐŽŶƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚ͘/ƚŝƐŶŽƚŝŶƚĞŶĚĞĚƚŽĐŽƌƌĞĐƚŵŝƐĂůŝŐŶĞĚƉŝƉĞƐĞĐƚŝŽŶƐŽƌƚŽƐĞƌǀĞĂƐ ĂŶĞůďŽǁ͘ ϰ͘ϰ͘'ŝǀĞŶƚŚĞĐŽŵďŝŶĞĚĞĨĨĞĐƚƐŽĨƉŝƉĞĨƌŝĐƚŝŽŶůŽƐƐĂŶĚƌĞŐƵůĂƚŽƌĚƌŽŽƉ͕ŐĂƐƉƌĞƐƐƵƌĞƐŚŽƵůĚƚLJƉŝĐĂůůLJŶŽƚ ĚƌŽƉŵŽƌĞƚŚĂŶϮ͟ǁ͘Đ͘ĨƌŽŵŶŽͲůŽĂĚƌƵŶŶŝŶŐƚŽĨƵůůͲůŽĂĚƌƵŶŶŝŶŐ͘hŶĚĞƌŶŽĐŝƌĐƵŵƐƚĂŶĐĞƐƐŚĂůůƚŚĞŐĂƐ ƉƌĞƐƐƵƌĞŵĞĂƐƵƌĞĚĂƚƚŚĞƚĞƐƚƉŽƌƚŽŶƚŚĞŝŶƐŝĚĞĨƌĂŵĞƌĂŝůŽĨƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĚƌŽƉďĞůŽǁƚŚĞŵŝŶŝŵƵŵ ƌĂƚĞĚŐĂƐƉƌĞƐƐƵƌĞůŝƐƚĞĚŽŶƚŚĞŐĞŶĞƌĂƚŽƌŶĂŵĞƉůĂƚĞ͘ ϰ͘ϱ͘&ƵůůͲƉŽƌƚďĂůůǀĂůǀĞƐ͕ƚŚĞƐĂŵĞĚŝĂŵĞƚĞƌĂƐƚŚĞƉŝƉĞǁŚŝĐŚƚŚĞLJĂƌĞĐŽŶŶĞĐƚĞĚƚŽ͕ĂƌĞƚŽďĞƵƐĞĚĨŽƌĂůů ƐŚƵƚͲŽĨĨƐ͘ ϰ͘ϲ͘&ŽƌŵƵůƚŝƉůĞŐĞŶĞƌĂƚŽƌƐĞƚŝŶƐƚĂůůĂƚŝŽŶƐ;'ĞŶĞƌĂĐDW^Ϳ͕ĞĂĐŚŐĞŶĞƌĂƚŽƌƐĞƚŵƵƐƚŚĂǀĞŝƚƐŽǁŶƌĞŐƵůĂƚŽƌ ŝŶƐƚĂůůĞĚ͘ŽŶŽƚƐŚĂƌĞĂƐŝŶŐůĞůĂƌŐĞƌĞŐƵůĂƚŽƌĂĐƌŽƐƐŵƵůƚŝƉůĞŐĞŶĞƌĂƚŽƌƐĞƚƐ͘ ϱ͘ZĞĐŽŵŵĞŶĚĞĚĞƐŝŐŶĞƐƚWƌĂĐƚŝĐĞƐ͗ ϱ͘ϭ͘WƌŽǀŝĚĞĂƉƉƌŽdžŝŵĂƚĞůLJϭϬĨĞĞƚŽĨƉŝƉĞďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚŐĞŶĞƌĂƚŽƌŐĂƐŝŶůĞƚ͘dŚŝƐĚŽĞƐŶŽƚŚĂǀĞ ƚŽďĞĂƐŝŶŐůĞƐƚƌĂŝŐŚƚƌƵŶ͘dŚĞƉŝƉĞǀŽůƵŵĞĚĞĐŽƵƉůĞƐƚŚĞĚLJŶĂŵŝĐƌĞƐƉŽŶƐĞŽĨƚŚĞŐĞŶĞƌĂƚŽƌƚŚƌŽƚƚůĞ ĐŽŶƚƌŽůƐLJƐƚĞŵĂŶĚƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌ͕ƌĞĚƵĐŝŶŐƚŚĞƉƌŽďĂďŝůŝƚLJŽĨŽƐĐŝůůĂƚŝŽŶĂŶĚƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ ϱ͘Ϯ͘ǀŽŝĚŝŶƐƚĂůůŝŶŐĞůďŽǁƐŽƌƉŝƉĞƐǁĂŐĞƐŝŵŵĞĚŝĂƚĞůLJƵƉƐƚƌĞĂŵŽƌĚŽǁŶƐƚƌĞĂŵŽĨĂƌĞŐƵůĂƚŽƌ͕ƵŶůĞƐƐ ƐƉĞĐŝĨŝĐĂůůLJĂůůŽǁĞĚďLJƚŚĞƌĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌ͘dŚŝƐǁŝůůŝŶĐƌĞĂƐĞƚŚĞƚƵƌďƵůĞŶĐĞŽĨƚŚĞŐĂƐĨůŽǁ͕ ŚĂǀŝŶŐĂŶĞŐĂƚŝǀĞŝŵƉĂĐƚŽŶƉƌĞƐƐƵƌĞƌĞŐƵůĂƚŝŽŶĂĐĐƵƌĂĐLJĂŶĚƐƚĂďŝůŝƚLJ͘ZĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌƐƚLJƉŝĐĂůůLJ ƌĞĐŽŵŵĞŶĚϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐŽĨƐƚƌĂŝŐŚƚƉŝƉĞƌƵŶƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŽĨĂƌĞŐƵůĂƚŽƌ͘&Žƌ ĞdžĂŵƉůĞ͕ŽŶĂƌĞŐƵůĂƚŽƌǁŝƚŚϮ͟ĚŝĂŵĞƚĞƌƉŝƉĞĨŝƚƚŝŶŐƐ͕ϮϬ͟ŽĨƐƚƌĂŝŐŚƚƉŝƉĞƐŚŽƵůĚďĞĨŝƚƚĞĚƵƉƐƚƌĞĂŵĂŶĚ ĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘tŚĞŶĨŝĞůĚĐŽŶĚŝƚŝŽŶƐƉƌŽŚŝďŝƚŵĞĞƚŝŶŐďŽƚŚĐŽŶƐƚƌĂŝŶƚƐ͕ƉůĂĐĞƚŚĞĞůďŽǁ ŽŶƚŚĞŚŝŐŚͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘dŚĞƐƚƌĂŝŐŚƚƌƵŶŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŝƐŵŽƌĞĐƌŝƚŝĐĂůĨŽƌ ƉƌŽƉĞƌƌĞŐƵůĂƚŽƌŽƉĞƌĂƚŝŽŶ͘ ϱ͘ϯ͘ǀŽŝĚŝŶƐƚĂůůŝŶŐƉŝƉĞƐǁĂŐĞƐŝŵŵĞĚŝĂƚĞůLJďĞĨŽƌĞŽƌĂĨƚĞƌĂŶĞůďŽǁ͘dŚĞĐŽŵďŝŶĞĚĨůŽǁƚƵƌďƵůĞŶĐĞŽĨƚŚĞ ƐǁĂŐĞĂŶĚĞůďŽǁŝŶĐůŽƐĞƉƌŽdžŝŵŝƚLJĐĂŶĐĂƵƐĞƵŶĞdžƉĞĐƚĞĚůLJůĂƌŐĞƉƌĞƐƐƵƌĞĚƌŽƉƐĂƚŚŝŐŚĨůŽǁƌĂƚĞƐ͘ ϱ͘ϰ͘DŝŶŝŵŝnjĞƚŚĞŶƵŵďĞƌŽĨϵϬͲĚĞŐƌĞĞĞůďŽǁƐ͘/ĨŵŽƌĞƚŚĂŶƚŚƌĞĞĞůďŽǁƐĂƌĞŶĞĞĚĞĚĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞ ƌĞŐƵůĂƚŽƌƚŽĂĐĐŽŵŵŽĚĂƚĞƚŚĞĚĞƐŝŐŶ͕ƐǁĞƉƚƌĂĚŝƵƐĞůďŽǁƐĂƌĞƌĞĐŽŵŵĞŶĚĞĚƚŽŵŝŶŝŵŝnjĞƉƌĞƐƐƵƌĞĚƌŽƉ͘ ϱ͘ϱ͘hƐĞŽĨĂŶŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƐƚƌŽŶŐůLJƌĞĐŽŵŵĞŶĚĞĚ͘ZĞŐƵůĂƚŽƌƐǁŝƚŚĞdžƚĞƌŶĂůƉƌĞƐƐƵƌĞ ƌĞŐŝƐƚƌĂƚŝŽŶůŝŶĞƐĂĚĚĂŶĂĚĚŝƚŝŽŶĂůǀĂƌŝĂďůĞŝŶƚŽƚŚĞƐLJƐƚĞŵƚŚĂƚĐĂŶďĞĚŝĨĨŝĐƵůƚƚŽƚƌŽƵďůĞƐŚŽŽƚƐŚŽƵůĚ ƚŚĞŐĂƐƉƌĞƐƐƵƌĞďĞĐŽŵĞƵŶƐƚĂďůĞƵŶĚĞƌŚŝŐŚͲĨůŽǁĐŽŶĚŝƚŝŽŶƐ͘ ϱ͘ϲ͘&ŽƌŵŽƌĞƐƚĂďůĞŐĂƐĨůŽǁǁŝƚŚůŽŶŐĞƌŐĂƐƉŝƉŝŶŐ͕ƚŚĞŚŝŐŚƉƌĞƐƐƵƌĞƐŝĚĞŵĂLJďĞƌĂŝƐĞĚĂƐŚŝŐŚĂƐĐŽĚĞ ĂůůŽǁƐĂŶĚƌĞŐƵůĂƚĞŝƚĚŽǁŶƚŽŐĞŶĞƌĂƚŽƌŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞĂƚƚŚĞŐĞŶĞƌĂƚŽƌ͘;dŚŝƐŝƐƚŚĞƐĂŵĞĚĞƐŝŐŶ ĐŽŶĐĞƉƚƵƐĞĚŝŶƚŚĞĞůĞĐƚƌŝĐĂůŝŶĚƵƐƚƌLJ͖͞ŚŝŐŚǀŽůƚĂŐĞĨŽƌůŽŶŐĚŝƐƚĂŶĐĞƐ͕ƚƌĂŶƐĨŽƌŵĂƚŝŽŶĂƚƚŚĞ ůŽĂĚƐ͟Ϳ͘dŚŝƐŵĂLJĂůƐŽŚĞůƉƌĞĚƵĐĞĐŽƐƚĂƐƉŝƉĞĚŝĂŵĞƚĞƌƐĐĂŶďĞƐŵĂůůĞƌ͕ƐĂǀŝŶŐŵĂƚĞƌŝĂůĂŶĚŝŶƐƚĂůůĂƚŝŽŶ ĐŽƐƚƐ͘ ϲ͘/ŶƐƚĂůůĂƚŝŽŶĂŶĚŽŵŵŝƐƐŝŽŶŝŶŐZĞĐŽŵŵĞŶĚĂƚŝŽŶƐ͗ ϲ͘ϭ͘ZĞĨĞƌƚŽ'ĞŶĞƌĂĐ͛Ɛ/ŶƐƚĂůůĂƚŝŽŶ'ƵŝĚĞůŝŶĞƐĨŽƌ^ƚĂƚŝŽŶĂƌLJ/ŶĚƵƐƚƌŝĂů'ĞŶĞƌĂƚŽƌƐ;ŽĐƵŵĞŶƚηϬϰϲϲϮϮͿĨŽƌ ĂĚĚŝƚŝŽŶĂůŝŶƐƚĂůůĂƚŝŽŶĚĞƚĂŝůƐ͘ ϲ͘Ϯ͘WŝŐĂůůŐĂƐƉŝƉĞƐĂĨƚĞƌŝŶƐƚĂůůĂƚŝŽŶƚŽƌĞŵŽǀĞƉŝƉĞĚŽƉĞ͕ǁĞůĚƐůĂŐĂŶĚŽƚŚĞƌĐŽŶƚĂŵŝŶĂŶƚƐƚŚĂƚĐŽƵůĚ ĚĂŵĂŐĞƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞƐĞĂƚĂŶĚĐĂƵƐĞƉƌĞƐƐƵƌĞĐƌĞĞƉ͘ ϲ͘ϯ͘/ŶƐƚĂůůĂĚŝƌƚƚƌĂƉĂŶĚͬŽƌƐĐƌĞĞŶďĞĨŽƌĞƚŚĞŐĂƐƌĞŐƵůĂƚŽƌ͘ ϲ͘ϰ͘^ĞƚƚŚĞƌĞŐƵůĂƚŽƌƉƌĞƐƐƵƌĞǁŝƚŚƚŚĞŐĞŶĞƌĂƚŽƌƌƵŶŶŝŶŐĂƚŶŽͲůŽĂĚ͘DĞĂƐƵƌĞŵĞŶƚƐĂƌĞƚĂŬĞŶĂƚƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůƉƌĞƐƐƵƌĞƚĞƐƚƉŽƌƚŽŶƚŚĞŝŶƐŝĚĞŽĨƚŚĞĨƌĂŵĞƌĂŝů͘&ŽƌƵŶŝƚƐĐŽŶĨŝŐƵƌĞĚĨŽƌϳ͟Ͳϭϭ͟ǁ͘Đ͘ ŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͕ƐĞƚƚŚĞƌĞŐƵůĂƚŽƌƚŽϭϭ͟ǁ͘Đ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐ͘&ŽƌƵŶŝƚƐĐŽŶĨŝŐƵƌĞĚĨŽƌϭϭͲϭϰ͟ǁ͘Đ͘ ŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͕ƐĞƚƚŚĞƌĞŐƵůĂƚŽƌƚŽϭϰ͟ǁ͘Đ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐ͘WƌĞƐƐƵƌĞĚƌŽŽƉĂƚĨƵůůͲůŽĂĚƌƵŶŶŝŶŐǁŝůů ďĞĂĐŽŵďŝŶĂƚŝŽŶŽĨƌĞŐƵůĂƚŽƌĚƌŽŽƉĂŶĚƉŝƉĞĨƌŝĐƚŝŽŶůŽƐƐ͘WƌŽƉĞƌĚĞƐŝŐŶǁŝůůůŝŵŝƚƚŚĞŶŽͲůŽĂĚƚŽĨƵůůͲůŽĂĚ ƌƵŶŶŝŶŐƉƌĞƐƐƵƌĞĚƌŽƉƚŽŶŽŵŽƌĞƚŚĂŶϮ͟ǁ͘Đ͘ĂŶĚĂƚŶŽƚŝŵĞĐĂŶƚŚĞŐĂƐƉƌĞƐƐƵƌĞĨĂůůďĞůŽǁƚŚĞ ŵŝŶŝŵƵŵƉƌĞƐƐƵƌĞůŝƐƚĞĚŽŶƚŚĞŐĞŶĞƌĂƚŽƌŶĂŵĞƉůĂƚĞ͘džƉĞĐƚƚŚĞůŽĐŬƵƉƐƚĂƚŝĐƉƌĞƐƐƵƌĞƚLJƉŝĐĂůůLJƚŽďĞ ŚŝŐŚĞƌƚŚĂŶƚŚĞŶŽͲůŽĂĚƌƵŶŶŝŶŐĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞ͘ ϳ͘DĞƚŚŽĚƐĨŽƌĐŽƌƌĞĐƚŝŶŐƵŶĚĞƐŝƌĂďůĞƉĞƌĨŽƌŵĂŶĐĞ͗ ϳ͘ϭ͘WƌĞƐƐƵƌĞƐƵƌŐŝŶŐĂŶĚĐLJĐůŝŶŐ͗^ŚŽƵůĚƚŚĞƌĞŐƵůĂƚŽƌĞdžƉĞƌŝĞŶĐĞ͞ŚƵŶƚŝŶŐ͟ŽƌŽƚŚĞƌƵŶƐƚĂďůĞŽƉĞƌĂƚŝŶŐ ďĞŚĂǀŝŽƌ͕ĂŶĞdžƚĞŶĚĞĚǀĞŶƚůŝŶĞŵĂLJďĞĐƌĞĂƚŝŶŐƌĞƐŽŶĂŶƚĐŽŶĚŝƚŝŽŶŽŶƚŚĞĂƚŵŽƐƉŚĞƌŝĐƐŝĚĞŽĨƚŚĞ ƌĞŐƵůĂƚŽƌĚŝĂƉŚƌĂŐŵ͘/ĨƚŚŝƐŝƐƐƵƐƉĞĐƚĞĚ͕ƚĞŵƉŽƌĂƌŝůLJĚŝƐĐŽŶŶĞĐƚƚŚĞǀĞŶƚůŝŶĞŽƌƌĞŵŽǀĞƚŚĞĐĂƉĨƌŽŵƚŚĞ ƌĞŐƵůĂƚŽƌƐƉƌŝŶŐĐĂƐĞĂŶĚŽďƐĞƌǀĞŝĨƚŚĞƵŶƐƚĂďůĞďĞŚĂǀŝŽƌƐƚŽƉƐ͘^ŚŽƌƚĞŶŝŶŐƚŚĞůĞŶŐƚŚŽƌŝŶĐƌĞĂƐŝŶŐƚŚĞ ĚŝĂŵĞƚĞƌŽĨƚŚĞǀĞŶƚůŝŶĞǁŝůůŽĨƚĞŶĐŽƌƌĞĐƚĂŶŝŶƐƚĂďŝůŝƚLJĐĂƵƐĞĚďLJǀĞŶƚůŝŶĞƌĞƐŽŶĂŶĐĞ͘ dŚĞƉŝƉĞǀŽůƵŵĞďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌŵĂLJďĞŝŶƐƵĨĨŝĐŝĞŶƚƚŽĚĞĐŽƵƉůĞƚŚĞ ĐŽŶƚƌŽůĂĐƚŝŽŶŽĨƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌ͛ƐƚŚƌŽƚƚůĞĐŽŶƚƌŽůƐLJƐƚĞŵ͘/ŶĐƌĞĂƐĞƚŚĞƉŝƉĞǀŽůƵŵĞ ďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌ͘ ŚĂŶŐĞƚŚĞƌĞƐƉŽŶƐĞƚŝŵĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘/ŶƐŽŵĞĐĂƐĞƐ͕ĂƐŵĂůůĂĚũƵƐƚŵĞŶƚŽĨƚŚĞƌĞŐƵůĂƚŽƌƐƉƌŝŶŐ;ƵƉ ŽƌĚŽǁŶϭǁ͘Đ͘ͿǁŝůůďĞĞŶŽƵŐŚƚŽƌĞƐƚŽƌĞƐƚĂďŝůŝƚLJƚŽƚŚĞƐLJƐƚĞŵ͘/ĨĂǀĂŝůĂďůĞĨŽƌƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌ͕ ƵƐŝŶŐƚŚĞŶĞdžƚŚŝŐŚĞƌƐƉƌŝŶŐŝƐĂŶŽƚŚĞƌŝŶĞdžƉĞŶƐŝǀĞĂŶĚĞĂƐLJƚŽŝŵƉůĞŵĞŶƚŽƉƚŝŽŶ͘dŚŝƐǁŝůůƐůŽǁƚŚĞ ƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞĂŶĚĐĂŶƌĞĚƵĐĞŽƌĞůŝŵŝŶĂƚĞƚŚĞŝŶƐƚĂďŝůŝƚLJ͘<ĞĞƉŝŶŵŝŶĚƚŚĂƚĐŚĂŶŐŝŶŐƚŽĂŚŝŐŚĞƌ ƐƉƌŝŶŐƌĂƚĞǁŝůůĂůƐŽŝŶĐƌĞĂƐĞƉƌĞƐƐƵƌĞĚƌŽŽƉĂŶĚƌĞĚƵĐĞƚŚĞƌĞŐƵůĂƚŽƌ͛ƐŵĂdžŝŵƵŵĨůŽǁĐĂƉĂĐŝƚLJǁŚŝĐŚ ůŝŵŝƚƐƚŚĞĂƉƉůŝĐĂďŝůŝƚLJŽĨƚŚŝƐĐŽƌƌĞĐƚŝǀĞŵĞĂƐƵƌĞ͘ ϳ͘Ϯ͘>ŽǁŐĂƐƉƌĞƐƐƵƌĞƵŶĚĞƌŚŝŐŚůŽĂĚ͗dŚĞƌĞĂƌĞƐĞǀĞƌĂůƉŽƚĞŶƚŝĂůĐĂƵƐĞƐŽĨůŽǁŐĂƐƉƌĞƐƐƵƌĞƵŶĚĞƌŚŝŐŚ ůŽĂĚ͘ WŝƉĞƌƵŶƐǁŝƚŚĞdžĐĞƐƐŝǀĞĨƌŝĐƚŝŽŶůŽƐƐĐĂƵƐĞĚďLJĂƉŝƉĞĚŝĂŵĞƚĞƌƚŚĂƚŝƐƚŽŽƐŵĂůůĨŽƌƚŚĞƌĞƋƵŝƌĞĚŐĂƐĨůŽǁ ĂŶĚƉŝƉĞůĞŶŐƚŚĂŶĚͬŽƌĂůĂƌŐĞŶƵŵďĞƌŽĨĞůďŽǁƐ͘dŚĞŽŶůLJĐŽƌƌĞĐƚŝǀĞĂĐƚŝŽŶĨŽƌƚŚŝƐŝƐƚŽŝŶĐƌĞĂƐĞƚŚĞ ƉŝƉĞĚŝĂŵĞƚĞƌďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌŽƌƚŽƌĂŝƐĞƚŚĞƉƌĞƐƐƵƌĞŽĨƚŚĞŚŝŐŚƉƌĞƐƐƵƌĞŐĂƐ͘ ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƵƐŝŶŐĂŐĂƐƉŝƉĞƐŝnjŝŶŐƚŽŽůĚƵƌŝŶŐƚŚĞĚĞƐŝŐŶƉŚĂƐĞ͘ /ŶƐƵĨĨŝĐŝĞŶƚƌĞŐƵůĂƚŽƌĐĂƉĂĐŝƚLJ͘ŽŶĨŝƌŵƚŚĞƵƉƐƚƌĞĂŵŐĂƐŵĂŝŶĂŶĚƌĞŐƵůĂƚŽƌĨůŽǁĐĂƉĂďŝůŝƚŝĞƐĨŽƌĂŐŝǀĞŶ ƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞ͘/ĨƚŚĞƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŝƐůŽǁĞƌƚŚĂŶŽƌŝŐŝŶĂůůLJĂŶƚŝĐŝƉĂƚĞĚ͕ŝŶǀĞƐƚŝŐĂƚĞƚŚĞ ƉŽƐƐŝďŝůŝƚLJĂĚũƵƐƚŝŶŐƚŚĞƵƚŝůŝƚLJƌĞŐƵůĂƚŽƌ;ŝĨƉƌĞƐĞŶƚͿ͘/ĨŝŶĐƌĞĂƐŝŶŐƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŝƐŶŽƚƉŽƐƐŝďůĞ͕Ă ůĂƌŐĞƌŽƌŝĨŝĐĞĂŶĚͬŽƌĚŝĨĨĞƌĞŶƚƐƉƌŝŶŐĐŽŵďŝŶĂƚŝŽŶŵĂLJďĞĂǀĂŝůĂďůĞĨŽƌƚŚĞĞdžŝƐƚŝŶŐƌĞŐƵůĂƚŽƌƚŽŝŶĐƌĞĂƐĞ ĨůŽǁĂŶĚƌĞĚƵĐĞƉƌĞƐƐƵƌĞĚƌŽŽƉ͘/ĨƚŚĞƉƌĞǀŝŽƵƐƐƚĞƉƐĨĂŝůƚŽĐŽƌƌĞĐƚƚŚĞƐŝƚƵĂƚŝŽŶ͕ĂůĂƌŐĞƌƌĞŐƵůĂƚŽƌǁŝůů ďĞƌĞƋƵŝƌĞĚ͘ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƚŚŽƌŽƵŐŚůLJƌĞǀŝĞǁŝŶŐƚŚĞƌĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌ͛ƐĨůŽǁƌĂƚĞƚĂďůĞƐ ƉƌŝŽƌƚŽŽƌĚĞƌŝŶŐ͘ ϳ͘ϯ͘džĐĞƐƐŝǀĞƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚƌŽƉĚƵƌŝŶŐŐĞŶĞƌĂƚŽƌĐƌĂŶŬĐLJĐůĞŽƌďůŽĐŬůŽĂĚĂƉƉůŝĐĂƚŝŽŶ͗/ĨƚŚĞƚƌĂŶƐŝĞŶƚ ƉƌĞƐƐƵƌĞĚƌŽƉĚƵƌŝŶŐĂŐĞŶĞƌĂƚŽƌĐƌĂŶŬĐLJĐůĞŽƌďůŽĐŬůŽĂĚĂƉƉůŝĐĂƚŝŽŶŝƐůĂƌŐĞĞŶŽƵŐŚƚŽŝŵƉĂĐƚ ƉĞƌĨŽƌŵĂŶĐĞ͕ƐƉĞĞĚŝŶŐƵƉƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞǁŝůůƌĞĚƵĐĞƚŚĞƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚƌŽƉ͘ǀŽŝĚƚŚŝƐ ƉƌŽďůĞŵďLJƵƐŝŶŐĂĚŝƌĞĐƚͲĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƚŚĂƚŝƐƐƵŝƚĂďůĞĨŽƌĞŶŐŝŶĞͲŐĞŶĞƌĂƚŽƌĂƉƉůŝĐĂƚŝŽŶƐ͘/ĨĂǀĂŝůĂďůĞ ĨŽƌƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌ͕ƵƐŝŶŐĂůŝŐŚƚĞƌƐƉƌŝŶŐǁŝůůŝŶĐƌĞĂƐĞƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞƐƉĞĞĚĂŶĚƌĞĚƵĐĞ ƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚŝƉ͘&ŝŶĂůůLJ͕ŝĨĂƌĞŵŽƚĞůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ŝŶĐƌĞĂƐĞƚŚĞƉŝƉĞĚŝĂŵĞƚĞƌŽĨ ƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐůŝŶĞ͘ ϳ͘ϰ͘WƌĞƐƐƵƌĞĐƌĞĞƉ͗ŶƐƵƌĞƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌŚĂƐĂůŽĐŬƵƉŽƌŚĂƌĚͲƐŚƵƚŽĨĨĨĞĂƚƵƌĞ͘WƌĞƐƐƵƌĞĐƌĞĞƉŝƐ ĂůŵŽƐƚĂůǁĂLJƐĐĂƵƐĞĚďLJĐŽŶƚĂŵŝŶĂŶƚƐŝŶƚŚĞƉŝƉĞƐLJƐƚĞŵƵƉƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘dŚĞĐŽŶƚĂŵŝŶĂŶƚƐ ĞŝƚŚĞƌŐĞƚĐĂƵŐŚƚŽŶƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞĚŝƐŬŽƌĐĂƵƐĞƉŚLJƐŝĐĂůĚĂŵĂŐĞƚŽƚŚĞǀĂůǀĞĚŝƐŬ͕ŵĂŬŝŶŐŝƚ ŝŵƉŽƐƐŝďůĞƚŽĂĐŚŝĞǀĞĂŚĂƌĚƐŚƵƚŽĨĨ͘ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƉŝŐŐŝŶŐĂůůƉŝƉĞĐŽŵƉŽŶĞŶƚƐƉƌŝŽƌƚŽŝŶƐƚĂůůŝŶŐ ƚŚĞƌĞŐƵůĂƚŽƌĂŶĚĞŶƐƵƌĞĂĚŝƌƚƚƌĂƉŝƐŝŶƐƚĂůůĞĚƵƉƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘ ϳ͘ϱ͘&ĂŝůƵƌĞƚŽƐƚĂƌƚ͕ƌƵŶƐŵŽŽƚŚůLJ͕ŽƌĂĐĐĞƉƚϭϬϬйůŽĂĚ͗ĂƌƌŝŶŐĂŵĞĐŚĂŶŝĐĂůĨĂŝůƵƌĞŽŶƚŚĞŐĞŶĞƌĂƚŽƌ͕ĨĂŝůƵƌĞ ƚŽŵĂŬĞϭϬͲƐĞĐŽŶĚƐƚĂƌƚ͕ƌƵŶƐŵŽŽƚŚůLJ͕ŽƌĐĂƌƌLJĨƵůůůŽĂĚŝƐĂůŵŽƐƚĂůǁĂLJƐĐĂƵƐĞĚďLJĂŶƵŶĚĞƌůLJŝŶŐŐĂƐ ƐƵƉƉůLJƉƌŽďůĞŵ͘ ϴ͘WƌŽƉĂŶĞsĂƉŽƌĂŶĚ>ŝƋƵŝĚ͗ ϴ͘ϭ͘WƌŽƉĂŶĞǀĂƉŽƌƐLJƐƚĞŵ͗dŚŝƐƚLJƉĞŽĨƐLJƐƚĞŵƵƐĞƐƚŚĞǀĂƉŽƌƐĨŽƌŵĞĚĂďŽǀĞƚŚĞůŝƋƵŝĚĨƵĞůŝŶƚŚĞƐƵƉƉůLJ ƚĂŶŬ͘dŚĞŵĂdžŝŵƵŵƚĂŶŬůŝƋƵŝĚĐĂƉĂĐŝƚLJŝƐϴϬйĂŶĚĂŵŝŶŝŵƵŵŽĨĂƉƉƌŽdžŝŵĂƚĞůLJϮϬйŽĨƚŚĞƚĂŶŬĐĂƉĂĐŝƚLJ ŝƐƌĞƋƵŝƌĞĚƚŽďŽŝůŽĨĨůŝƋƵŝĚŝŶƚŽƚŚĞǀĂƉŽƌƐƚĂƚĞ͘'ĂƐƉƌĞƐƐƵƌĞĂŶĚǀŽůƵŵĞƌĞƋƵŝƌĞŵĞŶƚƐĨŽƌĂŶ>W' ƐLJƐƚĞŵĂƚƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽĨƚŚĞŐĞŶĞƌĂƚŽƌĂƌĞůŝƐƚĞĚŽŶƚŚĞƵŶŝƚƐƉĞĐŝĨŝĐĂƚŝŽŶƐŚĞĞƚ͘dŚĞƉŝƉŝŶŐ ƐLJƐƚĞŵĐŽŶŶĞĐƚŝŶŐƚŚĞŽƵƚůĞƚŽĨƚŚĞĨŝƌƐƚƐƚĂŐĞƌĞŐƵůĂƚŽƌƚŽƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽŶƚŚĞƐĞĐŽŶĚƐƚĂŐĞ ƌĞŐƵůĂƚŽƌŵƵƐƚďĞƉƌŽƉĞƌůLJƐŝnjĞĚƚŽƉƌŽǀŝĚĞƚŚĞĨƵĞůǀŽůƵŵĞƌĞƋƵŝƌĞĚďLJƚŚĞƵŶŝƚĂƚϭϬϬйůŽĂĚ͘ dŚĞƉŝƉŝŶŐƐLJƐƚĞŵďĞƚǁĞĞŶƚŚĞŽƵƚůĞƚŽĨƚŚĞƐĞĐŽŶĚƐƚĂŐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚ ŵƵƐƚďĞƐŝnjĞĚƚŽƉƌŽǀŝĚĞƚŚĞĨƵĞůǀŽůƵŵĞƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌĂƚϭϬϬйůŽĂĚǁŚŝůĞĂůƐŽƐƚĂLJŝŶŐ ǁŝƚŚŝŶƚŚĞƉƌĞƐƐƵƌĞƌĂŶŐĞŶŽƚĞĚŽŶƚŚĞƵŶŝƚƐƉĞĐŝĨŝĐĂƚŝŽŶƐŚĞĞƚ͘ ϴ͘Ϯ͘dĂŶŬǀĂƉŽƌŝnjĂƚŝŽŶƌĂƚĞ͗/ŶĂĚĚŝƚŝŽŶƚŽƐŝnjŝŶŐƚŚĞŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵŝŶĂƐŝŵŝůĂƌŵĂŶŶĞƌƚŽŶĂƚƵƌĂůŐĂƐ͕>WͲ ǀĂƉŽƌƐLJƐƚĞŵƐŵƵƐƚĂůƐŽƐŝnjĞƚŚĞƉƌŽƉĂŶĞƐƚŽƌĂŐĞƚĂŶŬƐƚŽĞŶƐƵƌĞĂƐƵĨĨŝĐŝĞŶƚǀŽůƵŵĞŽĨŐĂƐǁŝůůďŽŝůŽĨĨ ƵŶĚĞƌĂƌĂŶŐĞŽĨĞŶǀŝƌŽŶŵĞŶƚĂůĐŽŶĚŝƚŝŽŶƐĂŶĚǀĂƌŝŽƵƐůŝƋƵŝĚůĞǀĞůƐŝŶƚŚĞƚĂŶŬ͘>ŝƋƵŝĚƉƌŽƉĂŶĞĂďƐŽƌďƐ ĂŵďŝĞŶƚŚĞĂƚĨƌŽŵƚŚĞƐƵƌƌŽƵŶĚŝŶŐĞŶǀŝƌŽŶŵĞŶƚƚŽďŽŝůŽĨĨůŝƋƵŝĚŝŶƚŽĂŐĂƐ͘>ŽǁůŝƋƵŝĚůĞǀĞůƐŝŶĂƚĂŶŬ ĐŽƵƉůĞĚǁŝƚŚĐŽůĚĂŵďŝĞŶƚƚĞŵƉĞƌĂƚƵƌĞƐĐĂŶƌĞƐƵůƚŝŶĂĐŽŶĚŝƚŝŽŶǁŚĞƌĞƚŚĞƚĂŶŬďŽŝůŽĨĨƌĂƚĞŝƐ ŝŶƐƵĨĨŝĐŝĞŶƚƚŽŵĞĞƚƚŚĞĚĞŵĂŶĚƐŽĨƚŚĞŐĞŶĞƌĂƚŽƌ͘ dŚĞůŽĐĂůƉƌŽƉĂŶĞƐƵƉƉůŝĞƌŝƐŽĨƚĞŶĂŐŽŽĚƌĞƐŽƵƌĐĞƚŽŚĞůƉǁŝƚŚƚĂŶŬƐŝnjŝŶŐ͘dŚĞŵĞƌƐŽŶͲ&ŝƐŚĞƌ>WͲ'ĂƐ ^ĞƌǀŝĐĞŵĂŶ͛Ɛ,ĂŶĚŬŝƐĂŶŽƚŚĞƌǀĂůƵĂďůĞƌĞƐŽƵƌĐĞĨŽƌƐŝnjŝŶŐƉƌŽƉĂŶĞƐLJƐƚĞŵƐĂŶĚŝŶĐůƵĚĞƐƚĂŶŬ ǀĂƉŽƌŝnjĂƚŝŽŶƚĂďůĞƐ͘ϴ/ŶŵĂŶLJĐĂƐĞƐ͕ƚŚĞƚĂŶŬǀŽůƵŵĞŵƵƐƚďĞůĂƌŐĞƌ;ƐŽŵĞƚŝŵĞƐŵƵĐŚůĂƌŐĞƌͿƚŚĂŶƚŚĞ ŐĂƐƌĞƋƵŝƌĞĚƚŽĂĐŚŝĞǀĞĂĚĞƐŝƌĞĚƌƵŶƚŝŵĞ͘tŚĞƌĞƉƌĂĐƚŝĐĂů͕ďƵƌŝĞĚƚĂŶŬƐĐĂŶŝŵƉƌŽǀĞƚŚĞǀĂƉŽƌŝnjĂƚŝŽŶ ƌĂƚĞďLJƉƌŽƚĞĐƚŝŶŐƚŚĞƚĂŶŬĨƌŽŵĞdžƚƌĞŵĞůLJůŽǁĂŵďŝĞŶƚĂŝƌƚĞŵƉĞƌĂƚƵƌĞƐ͘ &ŝŐƵƌĞϲ͗ďŽǀĞŐƌŽƵŶĚD^dĂŶŬǀĂƉŽƌŝnjĂƚŝŽŶ ƌĂƚĞ͕>WͲ'ĂƐ^ĞƌǀŝĐĞŵĂŶΖƐ,ĂŶĚŬ͘ ϴ͘ϯ͘>ŝƋƵŝĚƉƌŽƉĂŶĞƐLJƐƚĞŵ͗dŚŝƐƐLJƐƚĞŵĚĞůŝǀĞƌƐƉƌŽƉĂŶĞŝŶĂůŝƋƵŝĚƐƚĂƚĞ;>W>ͿƚŽƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽŶƚŚĞ ŐĞŶĞƌĂƚŽƌƐĞƚ͘>ŝƋƵŝĚƉƌŽƉĂŶĞƐLJƐƚĞŵƐĂƌĞƵƐĞĚǁŚĞƌĞŝƚŝƐŝŵƉƌĂĐƚŝĐĂůƚŽĂĐŚŝĞǀĞƚŚĞƌĞƋƵŝƌĞĚďŽŝůŽĨĨ ƌĂƚĞĨƌŽŵƚŚĞĂǀĂŝůĂďůĞĨƵĞůƚĂŶŬǀŽůƵŵĞ͘&ŽƌƚŚĞĞŶŐŝŶĞƚŽƵƐĞƚŚĞ>W>ĨƵĞů͕ƚŚĞůŝƋƵŝĚŵƵƐƚďĞǀĂƉŽƌŝnjĞĚ ƉƌŝŽƌƚŽďĞŝŶŐĚĞůŝǀĞƌĞĚƚŽƚŚĞĨƵĞůŵŝdžĞƌ;ĐĂƌďƵƌĞƚŽƌͿ͘>W>ǁŝůůǀĂƉŽƌŝnjĞĂƚĂƚĞŵƉĞƌĂƚƵƌĞŽĨ;ͲϰϰΣ&ͬͲ ϰϮ͘ϮΣͿ͘dŚĞŐĞŶĞƌĂƚŽƌƐĞƚ>W>ĨƵĞůƐLJƐƚĞŵĚĞůŝǀĞƌLJƉƌĞƐƐƵƌĞŽƉĞƌĂƚĞƐŽǀĞƌƚŚĞƌĂŶŐĞŽĨϱϴͲϭϴϬƉƐŝ;ϰϬϬͲ ϭϮϰϮŬWĂͿ͕ĚĞƉĞŶĚŝŶŐŽŶƚŚĞĂŵďŝĞŶƚƚĞŵƉĞƌĂƚƵƌĞĂŶĚůŝƋƵŝĚůĞǀĞůŝŶƚŚĞƐƚŽƌĂŐĞƚĂŶŬ͘>W>ĞŶƚĞƌƐƚŚĞ ǀĂƉŽƌŝnjĞƌĂŶĚƉĂƐƐĞƐŝŶƚŽĂ͞ĨůĂƐŚ͟ĐŚĂŵďĞƌ͘dŚĞƉƌĞƐƐƵƌĞĚƌŽƉŝŶƚŚŝƐĐŚĂŵďĞƌǀĂƉŽƌŝnjĞƐƚŚĞůŝƋƵŝĚƚŽĂ ŐĂƐĂŶĚŝƐƌĞŐƵůĂƚĞĚƚŽϭϭ͟Ͳϭϰ͟ǁ͘Đ͘;Ϯ͘ϵͲϯ͘ϱŬWĂͿ͘,ĞĂƚĞĚĞŶŐŝŶĞĐŽŽůĂŶƚĨƌŽŵƚŚĞũĂĐŬĞƚǁĂƚĞƌŚĞĂƚĞƌŝƐ ƵƐĞĚƚŽŚĞĂƚƚŚĞĨůĂƐŚĐŚĂŵďĞƌŽĨƚŚĞǀĂƉŽƌŝnjĞƌĂŶĚƚŽƉƌĞǀĞŶƚƚŚĞǀĂƉŽƌŝnjĞƌĨƌŽŵŝĐŝŶŐ͘ ƚŚĞƉƌŝŵĂƌLJƐŽƵƌĐĞŵĂLJŶŽƚďĞĂǀĂŝůĂďůĞĚƵƌŝŶŐĂƉŽǁĞƌŽƵƚĂŐĞ͘ƵĂůĨƵĞůƐLJƐƚĞŵƐƵƐĞŶĂƚƵƌĂůŐĂƐĂƐƚŚĞ ƉƌŝŵĂƌLJĨƵĞůĂŶĚ>W'Žƌ>W>ǁŝƚŚĚƌĂǁĂůĂƐƚŚĞƐĞĐŽŶĚĂƌLJĨƵĞů͘&ŽƌĚƵĂůĨƵĞůƵŶŝƚƐ͕ƚŚĞƐƉĞĐŝĨŝĐĨƵĞů ϴ͘ϰ͘ƵĂůĨƵĞů͕ŶĂƚƵƌĂůŐĂƐƉƌŝŵĂƌLJĂŶĚƉƌŽƉĂŶĞƐĞĐŽŶĚĂƌLJ͗^ŽŵĞĂƉƉůŝĐĂƚŝŽŶƐƵƐĞĂĚƵĂůĨƵĞůƐLJƐƚĞŵǁŚĞƌĞ ƉƌĞƐƐƵƌĞ͕ǀŽůƵŵĞ͕ĂŶĚƉŝƉĞƐŝnjŝŶŐƌĞƋƵŝƌĞŵĞŶƚƐĨŽƌĞĂĐŚĨƵĞůƚLJƉĞŵƵƐƚďĞŽďƐĞƌǀĞĚ͘ ϵ͘ĚĚŝƚŝŽŶĂůƌĞƐŽƵƌĐĞƐ͗ ϭE&Wϯϳ͞/ŶƐƚĂůůĂƚŝŽŶĂŶĚƵƐĞŽĨ^ƚĂƚŝŽŶĂƌLJŽŵďƵƐƚŝŽŶŶŐŝŶĞƐ͟ E&Wϱϰ͞EĂƚŝŽŶĂů&ƵĞů'ĂƐŽĚĞ͟ E&Wϱϴ͞>W'ĂƐŽĚĞ͟ &ƌĞĞĂĐĐĞƐƐƚŽǀŝĞǁE&WĐŽĚĞĚŽĐƵŵĞŶƚƐĐĂŶďĞĨŽƵŶĚĂƚ͗ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ŶĨƉĂ͘ŽƌŐͬŽĚĞƐͲĂŶĚͲ^ƚĂŶĚĂƌĚƐͬůůͲŽĚĞƐͲĂŶĚͲ^ƚĂŶĚĂƌĚƐͬ&ƌĞĞͲĂĐĐĞƐƐ͘ ϮĂƚĂƐŚĞĞƚƐĨŽƌ'ĞŶĞƌĂĐ/ŶĚƵƐƚƌŝĂůŐĂƐŐĞŶĞƌĂƚŽƌƐĞƚƐ͗ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ŐĞŶĞƌĂĐ͘ĐŽŵͬ/ŶĚƵƐƚƌŝĂůͬƉƌŽĚƵĐƚƐͬŐĂƐĞŽƵƐͲŐĞŶĞƌĂƚŽƌƐ͘ ϯŵŽƌĞƚŚŽƌŽƵŐŚĚĞƐĐƌŝƉƚŝŽŶŽĨƚŚĞŽƉĞƌĂƚŝŽŶĂůƉƌŝŶĐŝƉůĞƐĂŶĚƉĞƌĨŽƌŵĂŶĐĞĂƚƚƌŝďƵƚĞƐŽĨŐĂƐƌĞŐƵůĂƚŽƌƐĐĂŶďĞ ĨŽƵŶĚŝŶŵĞƌƐŽŶͲ&ŝƐŚĞƌ͛ƐEĂƚƵƌĂů'ĂƐƉƉůŝĐĂƚŝŽŶ'ƵŝĚĞĂƚ͗ ŚƚƚƉ͗ͬͬǁǁǁ͘ĞŵĞƌƐŽŶ͘ĐŽŵͬĞŶͲƵƐͬĂƵƚŽŵĂƚŝŽŶͬǀĂůǀĞƐͲĂĐƚƵĂƚŽƌƐͲƌĞŐƵůĂƚŽƌƐͬƌĞŐƵůĂƚŽƌƐ͘ ϰĂƵƐĞƐĂŶĚƵƌĞƐŽĨZĞŐƵůĂƚŽƌ/ŶƐƚĂďŝůŝƚLJ͕ůĂƐƐηϲϬϭϬ͘tŝůůŝĂŵ,ĂƌŶĞLJ͕&ŝƐŚĞƌŽŶƚƌŽůƐ/ŶƚĞƌŶĂƚŝŽŶĂů/ŶĐ͘ϭϵϵϱ͘ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ƐĐƌŝďĚ͘ĐŽŵͬĚŽĐƵŵĞŶƚͬϭϵϳϲϱϯϴϰϭͬĂƵƐĞƐͲĂŶĚͲƵƌĞƐͲŽĨͲZĞŐƵůĂƚŽƌͲ/ŶƐƚĂďŝůŝƚLJ ϱ^ĞŶƐƵƐƉƌŽĚƵĐƚĚĂƚĂƐŚĞĞƚƐ͗ŚƚƚƉƐ͗ͬͬƐĞŶƐƵƐ͘ĐŽŵͬƉƌŽĚƵĐƚƐ͍ͬƵƚŝůŝƚLJсŐĂƐ ϲdŚĞĞƌŶŽƵůůŝĨĨĞĐƚǁŝůůĐĂƵƐĞĂĚŝĨĨĞƌĞŶĐĞŝŶŐĂƐƉƌĞƐƐƵƌĞŽŶůLJǁŚĞŶŐĂƐŝƐĨůŽǁŝŶŐ͘tŚĞŶĂƌĞŵŽƚĞƐĞŶƐŝŶŐ ƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ĂŶĚƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐƉŽŝŶƚŝƐůŽĐĂƚĞĚŝŶĂƉŝƉĞƐĞĐƚŝŽŶƚŚĂƚŝƐĂůĂƌŐĞƌĚŝĂŵĞƚĞƌƚŚĂŶƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚ͕ƵŶĚĞƌŚŝŐŚͲĨůŽǁĐŽŶĚŝƚŝŽŶƐŝƚĐĂŶƌĞƐƵůƚŝŶĂŶĂĚĚŝƚŝŽŶĂůϭ͟ͲϮ͟ǁ͘Đ͘ŽĨƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶĐĞƚŚĂƚ ĐĂŶŶŽƚďĞĞůŝŵŝŶĂƚĞĚ͘ŚƚƚƉƐ͗ͬͬĞŶ͘ǁŝŬŝƉĞĚŝĂ͘ŽƌŐͬǁŝŬŝͬĞƌŶŽƵůůŝйϮϳƐͺƉƌŝŶĐŝƉůĞ ϳWŽǁĞƌĞƐŝŐŶWƌŽŝƐ'ĞŶĞƌĂĐ͛ƐǁĞďͲďĂƐĞĚŐĞŶĞƌĂƚŽƌƐŝnjŝŶŐƚŽŽůƚŚĂƚŝŶĐůƵĚĞƐŵŽĚƵůĞƐĨŽƌŐĂƐƐƵƉƉůLJƉŝƉĞƐŝnjŝŶŐ ĂŶĚĞdžŚĂƵƐƚƉŝƉĞƐŝnjŝŶŐ͘/ƚĐĂŶďĞĂĐĐĞƐƐĞĚĂŶĚƵƐĞĚĨƌĞĞŽĨĐŚĂƌŐĞĂƚ͗ŚƚƚƉƐ͗ͬͬƉĚƉ͘ƉŽǁĞƌĚĞƐŝŐŶƉƌŽ͘ĐŽŵ͘ ϴ>WͲ'ĂƐ^ĞƌǀŝĐĞŵĂŶ͛Ɛ,ĂŶĚŬ͕ŵĞƌƐŽŶ&ŝƐŚĞƌ͘ ŚƚƚƉ͗ͬͬǁǁǁ͘ƐƋƵŝďďƚĂLJůŽƌ͘ĐŽŵͬƵƉůŽĂĚĞĚͬůƉϭϬƐĞƌǀŝĐĞŵĂŶŝŶƐƚ͘ƉĚĨ 4 Generac Power Systems, Inc. P. O. B o x 8 Waukesha , WI 53189 888-GENERAC © 2018 Generac Power Systems, Inc. All rights reserved. Document No. 10000046207 LEGEND CT1CT2CT3MLCBMLCBNBNBCOMPONENTS LOCATED IN ALTERNATOR CONNECTION BOXIFTEXCCOMPONENTS LOCATED IN HIGH VOLTAGE CUSTOMER CONNECTION MODULECONNECTIONSFOR 1Ø UNITCONNECTIONSFOR 3Ø UNITIFT34TB5COMPONENTS LOCATED IN HIGH VOLTAGE CUSTOMER CONNECTION MODULERUN RELAYTB4125ARECEPTACLE240VGFCILOAD CENTERUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYGROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14PAGE 1 OF 10PAGE 2 OF 10 RB3ARB3TB1TB2COMPONENTS LOCATED ON LOW VOLTAGE CUSTOMER CONNECTION PANEL**F4F3F2F1COCOSWCTB3SWCSWCSWCSW1COSWCES1AH1AVRCBRB1RB1ACOMPONENTS LOCATED IN CONTROL PANELR1DBCOMMODCO3GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14PAGE 3 OF 10PAGE 4 OF 10 LP VAPORFS3FSRFS1FS2FS4AFSLFPFSRFS1FS4FS2LFPFS3NATURAL GASAFSCOMPONENTS LOCATED ON ENGINELFPFOR DUAL FUEL NG/LPL UNITS ONLYFSRFS2FS1LP LIQUIDNATURAL GASUS & CANADA ONLYAFSFSRFS1FSAUXGNDALTSMSCBCCBCHBCCCOCOMPONENTS LOCATED ON ENGINEOSFSPCO21AFSLP LIQUIDCOUS & CANADA ONLYUS & CANADA ONLYGROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14PAGE 5 OF 10PAGE 6 OF 10 FOR DUAL FUEL NG/LPV UNITS ONLYFSRLFPFS1FS5FS2FS6FS4FS3FS8FS7COMPONENTS LOCATED ON ENGINELP VAPOR NATURAL GASAFSUS & CANADA ONLYWLS1OTS1WTS1MPU1OPS1OTS WTSOTCCOMPONENTS LOCATED ON ENGINEDISTWTSOPTIONALGAGA1GDINSGROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14PAGE 7 OF 10PAGE 8 OF 10 J1J2ENGINE CONTROL MODULE CONNECTORSPAGE LEFT BLANK INTENTIONALLYGROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14GROUP GWIRING - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9856REVISION: J-7672-FDATE: 1/31/14PAGE 9 OF 10PAGE 10 OF 10 CT1CT2CT3CT2CT1IFTIFTOTS1GA1WLS1WTS1 OPS1GAGDOTSWTSWLSMPU1AFSFS4 FS5FS2 FS3FS1LFPFOR DUAL FUEL NG/LPV UNITS ONLYFS2FS1LFPFOR DUAL FUEL NG/LPL UNITS ONLYOSFS2US & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYFS6FS7FS8FS1FOR LPL UNITS ONLY US & CANADA ONLYMLCBFS1LFPRB3STBCHSMALTSCBATFS3FS2FS4FOR NG & LPV UNITS ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYFSAUXFSAUXGROUP GSCHEMATIC - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9857REVISION: J-7672-EDATE: 1/31/14GROUP GSCHEMATIC - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9857REVISION: J-7672-EDATE: 1/31/14PAGE 1 OF 4PAGE 2 OF 4 RB1COMBCHES1FAH1SW1AVRDBR1CBDISTINSAVR CONNECTORJ1ENGINE CONTROL MODULE CONNECTIONSJ2GD CONNECTORGROUP GSCHEMATIC - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9857REVISION: J-7672-EDATE: 1/31/14GROUP GSCHEMATIC - DIAGRAMG9.0L G18 12V H-PANELDRAWING #: 0H9857REVISION: J-7672-EDATE: 1/31/14PAGE 3 OF 4PAGE 4 OF 4 GENERATOR CONTROLS1 OF 1 Part No. 0191120SSDRev. &//1Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187P: (262) 544-4811 © 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. CONTROL INTERCONNECTIONS H-PANEL, CCI GTS TRANSFER SWITCH RB3 HTS TRANSFER SWITCH RAP/RRP LOW VOLTAGE CONNECTION PANEL SPARE OUTPUTS NOTE 1 + 3 NOTE 4 NOTE 5 NOTES: SPARE OUTPUTS ARE STANDARD ON INDUSTRIAL PRODUCT ONLY. GENLINK™ REQUIRED FOR PROGRAMMING. CONTACTS RATED $$7 9$&9'&. TB4 MAX WIRE SIZE: #10 AWG, RECOMMENDED TIGHTENING TORQUE: 14 LB-IN TB1, TB2 & RB3 MAX WIRE SIZE: #14 AWG RECOMMENDED TIGHTENING TORQUE: 12 LB-IN REFER TO H-PANEL MANUAL FOR INSTRUCTIONS ON ENABLING HTS TRANSFER SWITCH. REFER TO HTS TRANSFER SWITCH MANUAL FOR DIP SWITCH SETTINGS FOR MULTIPLE HTS APPLICATIONS. CONNECT THE RS485 OVERALL SHIELD AT GENSET CONNECTION TERMINAL ONLY. NOTE 5 125ALOAD CENTER TB1 TB2 HIGH VOLTAGE CONNECTION PANEL NOTE 2 NOTE 3 NOTE 3 TB4 120/240 VACUTILITY SUPPLY (BY CUSTOMER) VERIFY COMPONENTRATINGS FOR PROPER SUPPLY VOLTAGE TO BE PROVIDED. Part No. 0184520SSDRev. B 03/01/12Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187P: (262) 544-4811 © 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Certification of Quality Generac Power Systems certifies that the products we manufacture have been built and tested in accordance with strict internal and external standards for quality. Our quality management system has been registered with the internationally recognized ISO 9001:2008 standard and our products comply with external standards that include, but are not limited to, CSA, NEMA, EGSA, ISO, and UL. The Generac Quality Management System (GQMS) ensures the highest standards of quality at every level of production, from raw materials to the finished product. This includes receiving inspection, in-process checks, product and process audits, testing, final inspections, and shipping standards. Tests of our products are performed in accordance with our internal procedures and controlled through the GQMS to ensure accuracy and effectiveness. The testing process and product designs comply with external standards which may include, but are not limited to: ISO 8528-5, ISO 3046, NFPA 99, NFPA 110, BS 5514, SAE J1349, and DIN 6271. Generac Power Systems has over one million square feet of manufacturing space and over 2000 employees dedicated to designing and manufacturing power generation equipment in our multiple State of Wisconsin, USA factories. All of our installed and mobile generators are built with pride by our skilled American workforce to ensure our customers receive the quality that they expect from Generac. We are committed to producing quality products for both our internal and external customers. We will continuously improve our processes and diligently measure all aspects of our business. Vice President of Quality Generac Power Systems, Inc. Waukesha, Wisconsin USA Daniel Waschow Generac Power Systems 2 Year (2B) Limited Warranty for Industrial Standby Generators For the period of warranty noted below, which begins upon the successful start-up and/or on-line activation of the unit, Generac Power Systems,Inc. “Generac” warrants that its Generator will be free from defects in material and workmanship for the items and period set forth below. Generacwill, at its discretion, repair or replace any part(s) which, upon evaluation, inspection and testing by Generac or an Independent Authorized ServiceDealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be evaluated by the nearest IndependentAuthorized Service Dealer. Emissions components are excluded from coverage under this extended warranty. Emissions warranty coverage isdetailed in a separate emissions warranty. Warranty Coverage: Warranty coverage period is for Two (2) years or two-thousand (2,000) hours, whichever occurs first. Limited Gearbox Coverage: Guidelines: The following will NOT be covered by this warranty: THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHERWARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTIES WHICH ARE ALLOWEDBY LAW, SHALL BE LIMITED IN DURATION TO THE TERMS OF THE EXPRESS WARRANTY PROVIDED HEREIN. SOME JURISDICTIONS DO NOTALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. GENERAC'S ONLYLIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANYINCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. SOMEJURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVELIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU ALSO HAVE OTHER RIGHTS UNDERAPPLICABLE LAW. FOR AUSTRALIA ONLY: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to areplacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have thegoods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.FOR NEW ZEALAND ONLY: Nothing in this warranty statement excludes, restricts or modifies any condition, warranty right or remedy whichpursuant to the New Zealand Legislation (Commonwealth or State) including the Fair Trading Practices Act of 1986 or the Consumer Guarantees Act1993 (“CGA”) applies to this limited warranty and may not be so excluded, restricted or modified. Nothing in this statement is intended to have theeffect of contracting out of the provisions of the CGA, except to the extent permitted by that Act, and these terms are to be modified to the extentnecessary to give effect to that intention. If you acquire goods from Generac Power Systems or any of its authorized resellers and distributors for thepurposes of a business, then pursuant to section 43(2) of the CGA, it is agreed that the provisions of the CGA do not apply. GENERAC POWER SYSTEMS, INC. • P.O. BOX 8 • Waukesha, WI, USA 53187Ph: (888) GENERAC (436-3722) • Fax: (262) 544-4851 To locate the nearest Independent Authorized Service Dealer and to download schematics, exploded views and parts lists visit our website: www.generac.com Part No. 0K3486 Revision E (2/16) Warranty Coverage in Year(s): 1 Warranty Coverage in Year(s): 2 Parts, Labor and Limited Travel Limited Parts Only Year(s): 1-5 Coverage Year(s): 6-10 Coverage Limited Parts and Labor Limited Parts Only 1.Unit must be registered and proof of purchase available.2.Any and all warranty repairs and/or concerns must be performed and/or addressed by an Independent Authorized ServiceDealer, or branch thereof. Repairs or diagnostics performed by individuals other than Independent Authorized Service Dealersnot authorized in writing by Generac will not be covered.3.This Warranty is transferable between ownership of original install site.4.Generac supplied engine coolant heaters (block-heaters),heater controls and circulating pumps are only covered during the first year of the warranty provision.5.Generac may choose to repair, replace or refund a piece of equipment in its sole discretion.6.Enclosures are warranted against rust for the first year of ownership only. Damage caused after receipt of generator is the responsibility of the owner and is not covered by this warranty. Nicks, scrapes, dents or scratches to the painted enclosure should be repaired promptly by the owner. 7.Warranty only applies to permanently wired and mounted units.8.Damage to any covered components or consequential damages caused by the use of a non-OEM part will not be covered by the warranty.9.Proof of performance of all required maintenance must beavailable.10.Travel allowance is limited to 300 miles maximum and seven and one half (7.5) hours maximum (per occurrence, whichever is less) round trip from the nearest Independent Authorized Service Dealer. Any additional travel required will not becovered.11.Engines, driven components and fuel tanks used in Generac’sstandby power products system can carry a separate manufacturer’s (OEM) warranty (the “OEM Warranties”), unless otherwise expressly stated. OEM Warranties are in addition to this Warranty. All warranty claims for defects in material and/or workmanship on Generac product OEM components, may be directed through the OEM distributor/dealer network. OEM Warranties may vary and are subject to change. Generac shall have no liability under OEM warranties. 1.Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up).2.Damage/failures to the generator and/or transfer switch system caused by accidents, shipping, handling, or improper storage.3.Damage/failures caused by operation with improper fuels, speeds, loads or installations other than what’s recommended or specified by Generac Power Systems.4.Damage to the generator and/or transfer switch due to the use of non-Generac parts and/or equipment, contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oil or coolants/antifreeze.5.Failures due to normal wear and tear, accident, misuse, abuse, neglect, improper installation, improper sizing, or rodent, reptile, and/or insect infestation.6.Rental equipment used while warranty repairs are being performed and/or any extraordinary equipment used for removal and/or reinstallation of generator (i.e. cranes, hoists, lifts, et. al.).7.Planes, ferries, railroad, buses, helicopters, snowmobiles, snow-cats, off-road vehicles or any other mode of transport deemed not standard by Generac. 8.Products that are modified or altered in a manner not authorizedby Generac in writing.9.Starting batteries, fuses, light bulbs, engine fluids and anyrelated labor.10.Steel enclosures that rust as a result of improper installation, location in a harsh or salt water environment, or are scratched where the integrity of applied paint is compromised.11.Units sold, rated or used for "Prime Power", "Trailer Mounted" or"Rental Unit" applications as defined by Generac. Contact an Independent Authorized Service Dealer for definitions.12.Shipping costs associated with expedited shipping.13.Additional costs for overtime, holiday or emergency labor costs for repairs outside of normal business hours. 14.Any incidental, consequential or indirect damages caused bydefects in materials or workmanship, or any delay in repair or replacement of the defective part(s).15.Failures caused by any act of God or external cause including without limitation, fire, theft, freezing, war, lightning, earthquake, windstorm, hail, water, tornado, hurricane, or any other matters which are reasonably beyond the manufacturer’s control. Garantía limitada de 2 años (2B) de Generac Power Systems para los generadores de respaldo industriales Durante el período de garantía indicado abajo, que comienza desde la puesta en marcha y/o activación exitosa en línea de la unidad, Generac PowerSystems, Inc. “Generac” garantiza que generador estará libre de defectos de material y/o mano de obra para los ítems y el período indicados a continuación.Generac, a su discreción, reparará o sustituirá cualquier pieza o piezas que, por medio de la evaluación, inspección y prueba efectuada por Generac o unConcesionario de servicio autorizado independiente de Generac, se determine que es o son defectuosa(s). Todo equipo que el comprador o propietarioreclame como defectuoso debe ser evaluado por el Concesionario de servicio autorizado independiente de Generac más cercano. Los componentesrelacionados con emisiones están excluidos de la cobertura bajo esta garantía extendida. La cobertura de la garantía de emisiones se detalla por separadoen una garantía de emisiones.Cobertura de la garantía: El período de cobertura de la garantía es de dos (2) años o dos mil (2000) horas, lo que ocurra primero. Cobertura limitada sobre la caja de engranajes: Directrices: Lo siguiente NO será cubierto por esta garantía: ESTA GARANTÍA SUSTITUYE CUALQUIER OTRA GARANTÍA, EXPRESA O IMPLÍCITA. ESPECÍFICAMENTE, GENERAC NO EXTIENDE NINGUNA OTRAGARANTÍA ACERCA DE LA COMERCIALIZACIÓN O APTITUD PARA UN PROPÓSITO EN PARTICULAR. LA DURACIÓN DE TODAS LAS GARANTÍASIMPLÍCITAS PERMITIDAS POR LA LEY ESTARÁ LIMITADA A LAS CONDICIONES DE LA GARANTÍA EXPRESA ESTIPULADA EN LA PRESENTE. ALGUNASJURISDICCIONES NO PERMITEN LIMITACIONES DE LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA; POR LO TANTO, LA LIMITACIÓN PRECEDENTE PUEDENO APLICARSE A USTED. LA ÚNICA RESPONSABILIDAD DE GENERAC SERÁ REPARAR O SUSTITUIR LA(S) PIEZA(S) COMO SE ESTIPULÓPRECEDENTEMENTE. GENERAC NO SERÁ RESPONSABLE EN NINGÚN CASO POR NINGÚN DAÑO ACCESORIO O EMERGENTE, AUN CUANDO TAL DAÑOSEA RESULTADO DIRECTO DE LA NEGLIGENCIA DE GENERAC. ALGUNAS JURISDICCIONES NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE DAÑOSACCESORIOS O EMERGENTES, DE MANERA QUE LA LIMITACIÓN PRECEDENTE PUEDE NO APLICARSE A USTED. ESTA GARANTÍA LE OTORGADERECHOS LEGALES ESPECÍFICOS. TAMBIÉN TIENE OTROS DERECHOS BAJO LA LEY CORRESPONDIENTE. SOLO PARA AUSTRALIA: Nuestros productos se entregan con garantías que no pueden ser excluidas según la Australian Consumer Law (Ley australiana deconsumidores). Usted tiene derecho a sustitución o reembolso por un fallo mayor y a compensación por cualquier otra pérdida o daño razonable previsible.Usted también tiene derecho a que los bienes sean reparados o sustituidos si los bienes no son de calidad aceptable y la falla no llega a ser un fallo mayor.SOLO PARA NUEVA ZELANDA: Nada de esta declaración de garantía excluye, restringe o modifica ninguna condición, derecho de garantía o solución que,conforme a la legislación de Nueva Zelanda (Comunidad o Estado), incluso la Fair Trading Practices Act (Ley de transacciones comerciales justas) de 1986 o laConsumer Guarantees Act (Ley de garantías de los consumidores, “CGA”) de 1993, se aplique a esta garantía limitada y por lo tanto no puede ser sometida aexclusiones, restricciones o modificaciones. Nada de esta declaración tiene el propósito de tener efecto de contratar fuera de las previsiones de la CGA, exceptocon el alcance permitido por la ley y estos términos se deben modificar con el alcance necesario para hacer efectiva esta intención. Si adquiere bienes deGenerac Power Systems o alguno de sus revendedores y distribuidores autorizados con propósitos comerciales, entonces, conforme a la sección 43(2) de laCGA, se acuerda que no se aplican las previsiones de la CGA. GENERAC POWER SYSTEMS, INC. • P.O. BOX 8 • Waukesha, WI 53187, EE. UU.Tel.: (888) GENERAC (436-3722) • Fax: (262) 544-4851 Para ubicar el Concesionario de servicio autorizado independiente más cercano y descargar diagramas esquemáticos, despieces y listas de piezas visite nuestro sitio Web: www.generac.com Núm. de pieza 0K3486 Revisión E (0/16) Cobertura de la garantía en el o los año(s): 1 Cobertura de la garantía en el o los año(s): 2 Sobre piezas, mano de obra y gastos de viaje limitados Limitada solo sobre piezas Año(s) de cobertura: 1-5 Cobertura Año(s) de cobertura: 6-10 Cobertura Limitada sobre piezas y mano de obra Limitada solo sobre piezas 1.La unidad debe estar registrada y tener prueba de compra disponible.2.Cualquiera y todas las reparaciones y/o preocupaciones por garantía deben ser efectuadas y/o dirigidas por un Concesionario de servicio autorizado independiente de Generac, o una sucursal de este. No serán cubiertas las reparaciones o los diagnósticos efectuados por personas diferentes de los Concesionarios de servicio autorizados independientes de Generac no autorizados por escrito por Generac.3.Esta garantía es transferible entre propietarios del sitio de instalación original.4.Los calentadores de refrigerante de motor (calentadores de bloque), los controles del calentador y las bombas de circulación suministrados por Generac solo están cubiertos durante el primer año de prestación de la garantía.5.Generac puede elegir reparar, sustituir o reembolsar una pieza del equipo a su exclusiva discreción. 6.Los gabinetes están garantizados contra corrosión solamente durante el primer año de propiedad. El daño causado después de la recepción del generador es responsabilidad del comprador y no está cubierto por esta garantía. Las muescas, raspaduras, abolladuras o rayaduras de gabinete pintado deben ser reparadas sin demora por el propietario. 7.La garantía corresponde solamente a las unidades conectadas y montadas en forma permanente.8.Los daños a cualquier componente o los daños emergentes causados por el uso de una pieza que no sea OEM no estarán cubiertos por la garantía.9.Debe haber disponible prueba de la ejecución de todo el mantenimiento requerido.10.Las asignaciones para viaje están limitadas a 300 millas como máximo y siete horas y media (7.5) horas como máximo (por ocurrencia, lo que sea menor), viaje de ida y vuelta, desde el Concesionario de servicio autorizado independiente de Generac más cercano. Todo gasto de viaje adicional requerido no será cubierto.11.Los motores, los componentes accionados y los tanques de combustible usados en los productos de respaldo de Generac pueden llevar una garantía de fabricante (OEM) separada (las “Garantías de OEM”), a menos que se estipule expresamente lo contrario. Las garantías de OEM son un agregado a esta garantía. Todos los reclamos de garantía por defectos de material y/o mano de obra en los componentes OEM del producto Generac, pueden ser dirigidos a través de la red de distribuidores/concesionarios OEM. Las garantías de OEM pueden variar y están sujetas a cambios. Generac no tendrá responsabilidad bajo las garantías de OEM. 1.Costes del mantenimiento normal (es decir: afinaciones, pieza[s] relacionada[s], ajustes, abrazaderas sueltas o con fugas, instalación y puesta en marcha).2.Daños/fallos del sistema de generador y/o interruptor de transferencia causados por accidentes, envío, manipulación, o almacenamiento incorrecto.3.Los daños/fallos causados por la operación con combustibles, velocidades, cargas, o instalaciones incorrectas diferentes de las recomendadas o especificadas por Generac Power Systems.4.Los daños al generador y/o el interruptor de transferencia debidos aluso de piezas y/o equipos que no sean de Generac; combustibles, aceites, refrigerantes/anticongelantes contaminados; o falta de combustibles, aceites, refrigerantes/anticongelantes apropiados.5.Fallos debidos a: desgaste y daño normal, accidente, uso indebido, abuso, negligencia, instalación incorrecta, dimensionamiento incorrecto, o plagas de roedores y/o insectos.6.Equipos arrendados usados mientras se llevan a cabo reparaciones de garantía y/o todos los equipos extraordinarios usados para retirar y/o reinstalar el generador, (esto es: grúas, malacates, elevadores, etc.).7.Aeronaves, transbordadores, ferrocarril, autobuses, helicópteros, motocicletas para nieve, camiones para nieve, vehículos fuera de ruta o cualquier otro modo de transporte no considerado estándar por Generac. 8.Productos que se modifiquen o alteren en forma no autorizada por Generac por escrito.9.Baterías de arranque, fusibles, bombillas de luz, fluidos para el motor y mano de obra relacionada.10.Los gabinetes de acero que se corroen debido a instalación incorrecta, ubicación en un entorno agresivo o con agua salada, o se rayen donde esté comprometida la integridad de la pintura aplicada.11.Las unidades vendidas, calificadas para, o usadas en aplicaciones de “Alimentación eléctrica principal”, “Montada en remolque” o “Unidad en alquiler” como las define Generac. Comuníquese con un Concesionario de servicio autorizado independiente para las definiciones.12.Costes de envío asociados con envío urgente.13.Costes adicionales por horas extra y feriados o los costes de mano de obra de emergencia por reparaciones fuera del horario de trabajo normal. 14.Todos los daños accesorios, emergentes o indirectos causados por defectos en los materiales o mano de obra o toda demora en la reparación o sustitución de la(s) pieza(s) defectuosa(s).15.Los fallos causados por cualquier acto de fuerza mayor o causa externa, que incluyen, sin limitaciones, incendio, robo, congelamiento, guerra, rayos, terremoto, tormenta de viento, granizo, agua, tornado, huracán, o cualesquiera otros asuntos que estén fuera del control razonable del fabricante. Garantie limitée de 2 ans (2B) de Generac Power Systems sur les générateurs de secours industriels Pendant la période de garantie mentionnée ci-bas, qui débute dès le démarrage réussi de l’appareil ou l’activation en ligne de l’appareil,Generac Power Systems, Inc. (Generac) garantit que son générateur sera exempt de vices de matériaux et fabrication en ce qui concerne les éléments et lapériode indiqués ci-dessous. À sa seule discrétion, Generac réparera ou remplacera toute pièce qui est jugée défectueuse après l’évaluation, l’inspection etla mise à l’essai par Generac ou un fournisseur de services d’entretien agréé indépendant. Tout équipement que l’acheteur/propriétaire prétend êtredéfectueux doit être évalué par le fournisseur de services d’entretien agréé indépendant le plus près. Les composantes relatives aux émissions ne sont pascouvertesen vertu de la présente garantie. La couverture des composantes relatives aux émissions est détaillée dans une garantie distincte. Couverture de la garantie : La période de garantie est de deux (2) ans ou de deux mille (2000) heures, selon la première éventualité. Couverture limitée de la boîte à engrenages : Lignes directrices : Les éléments suivants ne seront PAS couverts par la présente garantie : LA PRÉSENTE GARANTIE REMPLACE TOUTES LES AUTRES GARANTIES, EXPLICITES OU IMPLICITES. EN PARTICULIER, GENERAC N’OFFRE AUCUNEAUTRE GARANTIE QUANT À LA QUALITÉ MARCHANDE OU À LA CONVENANCE À UN USAGE PARTICULIER. TOUTE GARANTIE IMPLICITE AUTORISÉEPAR LA LOI SERA LIMITÉE À LA DURÉE DE LA PÉRIODE DE LA PRÉSENTE GARANTIE EXPLICITE. CERTAINS ÉTATS OU PROVINCES NE PERMETTENTPAS LES LIMITATIONS SUR LA DURÉE D’UNE GARANTIE IMPLICITE ET, PAR CONSÉQUENT, LA PRÉSENTE LIMITATION PEUT NE PAS S’APPLIQUER. LARESPONSABILITÉ DE GENERAC SE LIMITERA À LA RÉPARATION OU AU REMPLACEMENT DES PIÈCES, COMME INDIQUÉ PRÉCÉDEMMENT. EN AUCUNCAS GENERAC NE POURRA ÊTRE TENUE RESPONSABLE DE DOMMAGES ACCESSOIRES OU SUBSÉQUENTS, MÊME SI LES DOMMAGES RÉSULTENTDIRECTEMENT DE LA NÉGLIGENCE DE GENERAC. CERTAINS ÉTATS OU PROVINCES N’AUTORISENT PAS L’EXCLUSION NI LA LIMITATION DESDOMMAGES ACCESSOIRES OU INDIRECTS ET, PAR CONSÉQUENT, LA LIMITATION ÉNONCÉE CI-DESSUS PEUT NE PAS S’APPLIQUER. CETTE GARANTIEVOUS CONFÈRE DES DROITS LÉGAUX PRÉCIS. VOUS POUVEZ ÉGALEMENT JOUIR D’AUTRES DROITS EN VERTU DES LOIS APPLICABLES. POUR L’AUSTRALIE UNIQUEMENT : Nos produits sont fournis avec des garanties qui ne peuvent être exclues en vertu de la loi australienne sur laconsommation (Australian Consumer Law). Vous avez droit à un remplacement ou à un remboursement pour une défaillance majeure et à une indemnisationpour toute autre perte ou tout dommage raisonnablement prévisible. Vous disposez également d’un droit à la réparation ou au remplacement si les produits nesont pas d’une qualité acceptable et si cette défaillance n’est pas considérée comme majeure.POUR LA NOUVELLE-ZÉLANDE UNIQUEMENT : Cette garantie n’exclut, ne restreint ni ne modifie aucune condition, aucun droit de garantie ou recours qui,conformément à la législation de Nouvelle-Zélande (Commonwealth ou État), y compris la loi sur la pratique commerciale loyale de 1986 (Fair Trading Practices Act) oula loi sur la protection du consommateur de 1993 (CGA ou Consumer Guarantees Act), s’applique à cette garantie limitée et ne peut pas être exclue, restreinte oumodifiée. Cette garantie ne vise en aucun cas à contourner les dispositions de la CGA, sauf dans la mesure permise par cette loi, et ces termes doivent être modifiésdans la mesure nécessaire pour donner effet à cette intention. Si vous faites l’acquisition d’un produit de Generac Power Systems ou d’un de ses distributeurs etrevendeurs autorisés à des fins commerciales, alors, conformément à l’article 43(2) de la CGA, il est convenu que les dispositions de la CGA ne s’appliquent pas. GENERAC POWER SYSTEMS, INC. • C.P. 8 • Waukesha, WI (É.-U.) 53187 Téléphone : (888) GENERAC (436-3722) • Télécopieur : (262) 544-4851 Pour trouver le fournisseur de services d’entretien agréé indépendant le plus près et pour télécharger les schémas, les vues éclatées et les listes de piècesvisitez notre site Web : www.generac.com Pièce no 0K3486 Révision E (/16) Période de garantie : 1 Période de garantie : 2 Pièces, main-d’œuvre et couverture limitée des déplacements Couverture limitée – pièces seulement Période : couverture de 1 à 5 ans Période : couverture de 6 à 10 ans Couverture limitée – pièces et main-d’œuvre Couverture limitée – pièces seulement 1.L’appareil doit être enregistré et la preuve d’achat doit être présentée sur demande.2.Toute réparation sous garantie doit être effectuée par un fournisseur de services d’entretien agréé indépendant ou l’une de ses succursales, et toute préoccupation doit être également traitée par un fournisseur de services d’entretien agréé indépendant de Generac ou l’une de ses succursales. Toute réparation ou évaluation effectuée par des personnes autres que des fournisseurs de services d’entretien agréés indépendants qui n’a pas été autorisée par écrit par Generac ne sera pas couverte.3.La présente garantie est transférable conjointement à la propriété du site d’installation d’origine.4.Les chaufferettes à liquide de refroidissement du moteur (chauffe-moteur), les commandes de chauffage et les pompes de circulationfournies par Generac ne sont couvertes que pendant la première année de la période de garantie.5.Generac peut choisir, à sa seule discrétion, de réparer, de remplacer ou de rembourser une pièce d’équipement. 6.Les boîtiers sont garantis contre la rouille pendant la première année de possession seulement. Les dommages causés après la réception du générateur sont la responsabilité du propriétaire et ne sont pas couverts par la présente garantie. Les entailles, éraflures, bosses ou égratignures au boîtier peint doivent être réparées sans délai par le propriétaire. 7.La garantie s’applique uniquement aux appareils montés et câblés en permanence.8.Aucun dommage ou dommage indirect à toute pièce couverte découlant de l’utilisation de pièces non fabriquées par un fabricant d’équipement d’origine ne sera couvert par la garantie.9.Une preuve d’exécution de tous les travaux d’entretien requis doit être présentée sur demande.10.La présente garantie couvre les déplacements aller-retour d’un maximum de 480 km (300 miles) et de sept heures et demie (7,5) (par déplacement, selon le moindre des deux) à partir du fournisseur de services d’entretien agréé indépendant le plus près. Tout déplacement supplémentaire requis ne sera pas couvert.11.Les moteurs, les pièces d’entraînement et les réservoirs de carburant utilisés dans les systèmes d’alimentation de secours de Generac peuvent être protégés au titre de la garantie d’un fabricant d’équipement distinct (les « garanties des fabricants d’équipement d’origine »), sauf indication expresse à l’effet contraire. Les garanties des fabricants d’équipement d’origine s’ajoutent à la présente garantie. Toute réclamation au titre de la garantie pour vices de matériaux ou de fabrication de pièces d’un fabricant d’équipement d’origine sur un produit Generac peut être faite auprès du distributeur ou du réseau de fournisseurs de ce fabricant d’équipement d’origine. Les garanties des fabricants d’équipement d’origine peuvent varier et faire l’objet de modifications. Generac n’a aucune responsabilité découlant des garanties offertes par les fabricants d’équipement d’origine. 1.Les coûts d’entretien normal (c’est-à-dire mises au point, réglages de pièces associées, ajustements, resserrage de fixations, installation et démarrage).2.Les dommages ou défaillances du générateur et/ou du commutateur de transfert causés par un accident, le transport, la manutention ou un entreposage inadéquat.3.Les dommages/défaillances causés par l’utilisation de carburants inappropriés ou l’utilisation à des vitesses, avec des charges ou selon une installation autres que ce qui est recommandé ou spécifié par Generac Power Systems.4.Les dommages au générateur et/ou au commutateur de transfert causés par l’utilisation de pièces ou d’équipement non fabriqués par Generac, de carburant, d’huile, de liquide de refroidissement et d’antigel contaminé ou encore du manque de carburant, d’huile, de liquide de refroidissement et d’antigel.5.Les défaillances causées par l’usure normale, un accident, une utilisation inappropriée, une utilisation abusive, une négligence, une installation inadéquate, un dimensionnement inadéquat ou une infestation de rongeurs, de reptiles ou d’insectes.6.L’équipement de location utilisé pendant que des réparations sous garantie sont effectuées et/ou tout équipement extraordinaire utilisé pour retirer ou réinstaller le générateur (c’est-à-dire grues, appareils de levage, élévateurs, etc.).7.Les avions, les traversiers, les trains, les autobus, les hélicoptères, les motoneiges, les dameuses, les véhicules hors route ou tout autre moyen de transport jugé non standard par Generac. 8.Les produits modifiés ou altérés d’une manière qui n’a pas été autorisée par écrit par Generac.9.Les batteries de démarrage, les fusibles, les ampoules électriques, les fluides de moteur et toute main-d’œuvre connexe.10.Les boîtiers en acier qui rouillent en raison d’une installation inadéquate, d’une installation dans un environnement difficile ou salin ou d’égratignures qui compromettent l’intégrité de la peinture appliquée sur le boîtier.11.Les appareils vendus, cotés ou utilisés selon les applications suivantes, telles qu’elles sont définies par Generac : « puissance électrique de base », « monté sur remorque » ou « unité de location ». Veuillez communiquer avec un fournisseur de services d’entretien agréé indépendant pour obtenir les définitions.12.Les coûts d’expédition liés à l’expédition accélérée.13.Les coûts supplémentaires liés aux heures supplémentaires, aux jours fériés ou aux services d’urgence pour toute réparation effectuée en dehors des heures normales de bureau. 14.Tout dommage accessoire, subséquent ou indirect causé par un défaut de matériau et de fabrication ou par tout retard dans la réparation ou le remplacement de pièces défectueuses.15.Les défaillances causées par un cas de force majeure ou une cause externe y compris, sans toutefois s’y limiter, le feu, le vol, le gel, la guerre, la foudre, un tremblement de terre, une tempête, la grêle, la pluie, une tornade, un ouragan ou toute autre situation raisonnablement hors du contrôle du fabricant. United States Environmental Protection Agency Warranty Statement (Stationary Emergency Spark-Ignited Generators) Warranty Rights, Obligations and Coverage The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System Warranty on your new stationary emergency engine. If during the warranty period, any emission control system or compo- nent on your engine is found defective in materials or workmanship, Generac will repair your engine at no cost to you for diagnosis, replace- ment parts and labor provided it be done by a Generac Authorized Warranty Service Facility. Your emission control system may include parts such as the fuel metering, ignition, and exhaust systems and other related emission related components listed below. Generac will warrant the emissions control systems on your 2009 and later model year engines provided there has been no abuse, neglect, unapproved modifica- tion, or improper maintenance of your engine. For engines less than 130 HP the warranty period is two years from the date of sale to the ulti- mate purchaser. For engines greater than or equal to 130 HP the warranty period is three years or 2500 hours of operation, whichever comes first, from the date of the engine being placed into service. For high-cost warranted components, the Emission Control System war- ranty is valid for 5 years or 3500 hours of operation, whichever comes first. Purchaser's/Owner's Warranty Responsibilities As the engine purchaser/owner you are responsible for the following: 1) The engine must be installed and configured in accordance to Gen- erac's installation specifications. 2) The completion of all maintenance requirements listed in your Owner's Manual. 3) Any engine setting adjustment must be done in accordance and consistent with the instructions in the Owner's Manual. 4) Any emission control system or com- ponent must be maintained and operated appropriately in order to ensure proper operation of the engine and control system to minimize emissions at all times. Generac may deny any/or all Emission Control System Warranty coverage or responsibility of the engine, or an emission control system or component on your engine thereof, if it has failed due to abuse, neglect, unapproved modification or improper maintenance, or the use of counterfeit and/or “gray market” parts not made, supplied or approved by Generac. Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service dealer, 1-800-333-1322 for the dealer nearest you. The purchaser/owner shall be responsible for any expenses or other charges incurred for service calls and/or transportation of the product to/from the inspection or repair facilities. The purchaser/owner shall be responsible for any and/or all damages or losses incurred while the engine is being trans- ported/shipped for inspection or warranty repairs. Contact Generac Power Systems Inc. for additional Emission Control System Warranty related information, Generac Power Systems, Inc., PO. Box 8, Waukesha, WI 53187, or call 1-800-333-1322 or www.generac.com. Important Note This warranty statement explains your rights and obligations under the Emission Control System Warranty, which is provided to you by Gen- erac pursuant to federal law. Note that this warranty shall not apply to any incidental, consequential, or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part(s). This warranty is in place of all other warranties, expressed or implied. Specifically, Generac makes no other warranties as to the merchantability or fitness for a particular purpose. Any implied warranties which are allowed by law, shall be limited in duration to the terms of the express warranty provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Emission Related Parts Include the Following (if so equipped) *High-Cost Warranted Component EmsnWrnty001 Revision F (04/15) 1) Fuel Metering System 1.1) Gasoline Carburetor Assembly and Internal Components A) Fuel Filter, B) Carburetor, C) Fuel Pump 1.2) Carburetion Assembly and Its Components A) Fuel Controller, B) Carburetor and Its Gaskets, C) Mixer and Its Gaskets, D) Primary Gas Regulator, E) Liquid Vaporizer 1.3) Fuel Regulator 2) Air Induction System Including A) Intake Pipe/Manifold, B) Air Cleaner 3) Ignition System Including A) Spark Plug, B) Ignition Module, C) Ignition Coil, D) Spark Plug Wires 4) Exhaust System A) Catalyst Assembly*, B) Exhaust Manifold, C) Muffler, D) Exhaust Pipe, E) Muffler Gasket 5) Crankcase Breather Assembly Including A) Breather Connection Tube, B) PCV Valve 6) Oxygen Sensor 7) Diagnostic Emission-Control System United States Environmental Protection Agency Compliance Requirements (Stationary Emergency Spark-Ignited Generators) Purchaser's/Owner's Record Keeping Responsibilities The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain your record keeping requirements for compliance with Subpart JJJJ- Standards of Performance for Stationary Spark Ignition Internal Combustion Engines as listed in the Electronic Code of Federal Regulations Title 40 Part 60. As the engine purchaser/owner who operates and maintains their certified emergency stationary engine and emission control system according to applicable emission related guidelines as specified in this Owner's Manual, you are required to meet the following notification and record keeping requirements to demonstrate compliance: 1) Maintain documentation that the engine is certified to meet emission standards. 2) Record keeping of maintenance conducted. 3) Record keeping of the provision allowing natural gas engines to operate using propane for a maximum of 100 hours per year as an alternate fuel solely during emergency operations provided the engine is not certified to operate on propane. 4) Meet all compliance notifications submitted to the purchaser/owner and maintain all supporting documentation. 5) Record keeping of hours of operation, including what classified the operation as emergency and how many hours are spent for non-emergency operation. For emergency engines greater than or equal to 130 HP, record keeping of hours of operation begins January 1, 2011. For emergency engines less than 130 HP, record keeping of hours of oper- ation begins January 1, 2009; engines are equipped with non-resettable hour meters to facilitate record keeping. Specific Air Quality Management or Air Pollution Control Districts may have different and additional record keeping/reporting requirements. Your permit to construct and/or operate the engine may be contingent upon compliance with those requirements. Check with your local Air Quality Management or Air Pollution Control District for specific requirements. Emergency stationary internal combustion engines (ICE) may be operated for the purpose of maintenance checks and readiness testing, provided that the tests are recommended by Federal, State or local government, Generac, or the insurance company associated with the engine. Maintenance checks and readiness testing of such units is limited to 100 hours per year. There is no time limit on the use of emer- gency stationary ICE in emergency situations. The purchaser/owner may petition the Administrator for approval of additional hours to be used for maintenance checks and readiness testing, but a petition is not required if the owner maintains records indicating that Federal, State, or local standards require maintenance and testing of emergency ICE beyond 100 hours per year. Emergency stationary ICE may operate up to 50 hours per year in non emergency situations, but those 50 hours are counted towards the 100 hours per year provided for maintenance and testing. The 50 hours per year for non-emergency situations cannot be used for peak shaving or to generate income for a facility to supply power to an electric grid or otherwise supply power as part of a financial arrangement with another entity. For purchaser/owner of emergency engines, any operation other than emergency operation, maintenance and testing, and operation in non-emergency situations for 50 hours per year, as permitted in this section is prohibited. If you operate and maintain your certified emergency stationary SI internal combustion engine and emissions control systems in accordance to the specifications and guidelines in this Owner’s Manual, EPA will not require engine performance testing. If not, your engine will be con- sidered non-certified and you must demonstrate compliance according to Subpart JJJJ - Standards of Performance for Stationary Spark Igni- tion Internal Combustion Engines as listed in the Electronic Code of Federal Regulations Title 40 Part 60. Emission-Related Installation Instructions Your certified emergency stationary engine has pre-set emission control systems or components that require no adjustment. Inspection and replacement of an emissions related component is required to be done so in accordance with the requirements cited in the United States Environmental Protection Agency Warranty Statement or can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service dealer, 1-800-333-1322 for the dealer nearest you. Failing to follow these instructions when installing a certified engine in a piece of non-road equipment violates federal law 40 CFR 1068.105 (b), subject to fines or penalties as described in the Clean Air Act. EmsnWrnty001 Revision F (04/15) ASCO®ASCO®ASCO® ASCO®ASCO®ASCO®ENGINE CONTROL CONTACTSLOAD DISCONNECT FEATURECOMMON ALARM & NOT IN AUTO SIGNALING FEATURESINPHASE TRANSFER FEATURE FOR LOAD TRANSFERSOURCE AVAILABILITY SIGNALSEXTERNAL POWER SUPPLY COMPATIBILITYLOAD CURRENT METERINGNON-AUTOMATIC (MANUAL) OPERATIONFOUR-FUNCTION SOFTWARE BUNDLEREMOTE CONTROL FEATURES ASCO® ASCO® ASCO® ASCO® ASCO® Engineering Submittal Package OXOBOXO Lofts Uncasville, CT 100kW Natural Gas Generator 400A Automatic Transfer Switch Presented to: Horton Electrical Services, LLC 97 River Rd. Canton, CT 06019 860-693-6388 www.hortonelectric.com Prepared by: Huntington Power 230 Long Hill Cross Rd Shelton, CT 06484 203-929-3203 www.huntingtonpower.com 230 Long Hill Cross Rd Shelton, CT 06484 203-929-3203 ~ 203 929 0713 (f) 34 E. Dudley Town Rd, Bloomfield, CT 06002 860-289-8790 ~ 860-282-0472 (f) 68 Enter Lane Islandia, NY 11749 631-563-4943 ~ 631-563-6057 (f) BILL OF MATERIAL SPECIFICATION SHEET 0K6449 SPEC SHT SG130 9.0L DOMESTIC CONTROL PANEL AND OPTIONS 0172110SBY SPEC SHEET H-100 CONTROL PANEL 0604160SSD 21-LIGHT/RELAY PANEL DATA ALTERNATOR AND OPTIONS 0182610SSD ALT DATA SHT 130 KW 0187980SBY GENPROTECT DATA SHEET UNIT OPTIONS 0161970SBY BATTERY INDEX 0163180SBY SERIES 2000 ENCL SPEC 0180230SBY SPEC SHEET RHINO COAT 0189370SSD EATON CB TABLE THERM/MAG 0191900SBY 2.5A & 10A BATT CHRGR H&G 0192390SSD EATON CB LUG DATA 0604400SSD ELEC GOV GAS ENG SUB DATA 084918Q_SBM BLOCK HTR 1500W 120V 084918Q SBM 0K9451B SOUND DATA G9.0 130KW L1A 0L6262 E STOP BRK GLS H PNL SUBM INSTALLATION DRAWINGS 10000002132 GAS SUPPLY CHECKLIST SUBMITTAL DOC 10000018595 INSTALL O/S G9.0L C-GRP 10000019123 INSTALL L1A G9.0L C-GRP 10000046207 GAS SYSTEM DESIGN GUIDELINES GENSET ELECTRICAL DRAWINGS 0K9429 WD G9.0L G18 TURBO H-PANEL 0K9430 SD G9.0L G18 TURBO H-PANEL SYSTEM INTERCONNECT DRAWINGS 0191120SSD INTERCONNECT DIAG H PANEL CERTIFICATIONS 0184520SSD QUALITY CERTIFICATION DOC 0K3486 STANDARD 2B WARRANTY 0K8347 ISO CERTIFICATE 9001 : 20 A0000074220 2019 EPA CERT KGNXB08.92O3-018 EMSNWRNTY001 EPA WARRANTY EMSN STATEMENT AUTOMATIC TRANSFER SWITCH 978732 ASCO GROUP G 260-400A ATS OUTLINE NEMA 1 978745 ASCO GROUP G 260-400A 3PH WIRING DIAGRAM Bill of Material Quantity 1 - Generac Industrial gas engine-generator consisting of the following features and accessories: 130 kW Rating, wired for 120/208 VAC three phase, 60 Hz Natural Gas fuel fuel system Stationary Emergency-Standby rated Level 1 Acoustic Enclosure, Steel Critical Muffler – Inside Enclosure 400A Circuit Breaker UL2200 Listed EPA Certified H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range -40 to 70 degrees C o Digital Microprocessor: Two 4-line x 20 displays, full system status 3 Phase sensing, +/-0.25% digital voltage regulation RS232, RS485 and Canbus remote ports Waterproof connections All engine sensors are 4-20ma for minimal interference Programmable I/O Built-in PLC for special applications o Engine function monitoring and control: Full range standby operation; programmable auto crank, E-Stop, Auto-Off-Manual switch Isochronous Governor, +/-0.25% frequency regulation Full system status on all AC output and engine function parameters Service reminders, trending, fault history (alarm log) I2T function for full generator protection Selectable low-speed exercise o 2-wire start controls for any 2-wire transfer switch 21 Light Remote Annunciator Battery Charger, 10 Amp, NFPA 110 compliant, installed 110 AH, 1100 CCA Group 8D Batteries, with rack, installed Coolant Heater, 1500W, 120VAC Std set of 3 Manuals 120V GFCI and 240V Outlet 2-Year Warranty Onsite Startup & Testing Quantity 1 - Automatic Transfer Switch consisting of the following features and accessories: Open Transition 400 Amp, 3 Pole, Solid Neutral 120/208 VAC three phase, 4 wire UL1008 Listed NEMA 1 Enclosure 1 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency *Assembled in the USA using domestic and foreign parts Image used for illustration purposes only POWERING AHEAD Generac ensures superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. But Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up - all at our facilities throughout Wisconsin. Because applying natural gas and LP-fueled engines to generators requires advanced engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility. Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas. Standby Power Rating 130 kW, 163 kVA, 60 Hz CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details. UL2200, UL508, UL489 CSA C22.2, B149 TM BS5514 and DIN 6271 ® SAE J1349 NFPA 37, 70, 99, 110 ®NEC 700, 701, 702, 708 ISO 3046, 8528, 9001 NEMA ICS1, ICS10, MG1, 250, ICS6, AB1 ANSI/IEEE C62.41 IBC 2009, CBC 2010, IBC 2012, ASCE 7-05, ASCE 7-10, ICC-ES AC-156 (2012) *EPA Certified Prime ratings are not available in the US or its Territories 2 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency ENGINE SYSTEM • Oil Drain Extension • Air Cleaner • Fan Guard • Stainless Steel Flexible Exhaust Connection • Factory Filled Oil & Coolant • Radiator Duct Adapter (Open Set Only) • Critical Exhaust Silencer/Catalyst Fuel System • NPT Fuel Connection on Frame • Primary and Secondary Fuel Shutoff Cooling System • Closed Coolant Recovery System • Factory-Installed Radiator • 50/50 Ethylene Glycol Antifreeze • Radiator Drain Extension • UV/Ozone Resistant Hoses Electrical System • Battery Charging Alternator • Battery Cables • Battery Tray • Rubber-Booted Engine Electrical Connections • Solenoid Activated Starter Motor ALTERNATOR SYSTEM • UL220 GENprotect™ Fault Protector • Class H Insulation Material • 2/3 Pitch • Skewed Stator • Brushless Excitation • Sealed Bearings • Amortisseur Winding • /RZ7HPSHUDWXUH5LVH& GENERATOR SET • Internal Genset Vibration Isolation • Separation of Circuits - High/Low Voltage • Separation of Circuits - Multiple Breakers • Wrapped Exhaust Piping (Enclosed Units Only) • Standard Factory Testing • 2 Year Limited Warranty (Standby Rated Units) • Capable to Accept Full Load in <10 Seconds • Silencer Mounted in the Discharge Hood (Enclosed Units Only) ENCLOSURE (If Selected) • Rust-Proof Fasteners with Nylon Washers to Protect Finish • High Performance Sound-Absorbing Material (Sound Attenuation Enclosures) • Gasketed Doors • Stamped Air-Intake Louvers • Upward Facing Discharge Hoods (Radiator and Exhaust) • Stainless Steel Lockable Handles • RhinoCoat™ - Textured Polyester Powder Coat Paint CONTROL SYSTEM Digital H Control Panel- Dual 4x20 Display Program Functions • Programmable Crank Limiter • 7-Day Programmable Exerciser • Special Applications Programmable Logic Controller • RS-232/485 Communications • All-Phase Sensing Digital Voltage Regulator • Utility Monitoring • 2-Wire Start Capability • Date/Time Fault History (Event Log) • Isochronous Governor Control • Waterproof/Sealed Connectors • Audible Alarms and Shutdowns • Not in Auto (Flashing Light) • Auto/Off/Manual Switch • E-Stop (Red Mushroom-Type) • NFPA110 Level I and II (Programmable) • Customizable Alarms, Warnings, and Events • Modbus® Protocol • Predictive Maintenance Algorithm • Sealed Boards • Password Parameter Adjustment Protection • Single Point Ground • 16 Channel Remote Trending • 0.2msec High Speed Remote Trending • Alarm Information Automatically Annunciated on the Display Full System Status Display • Power Output (kW) • Power Factor • kW Hours, Total & Last Run • Real/Reactive/Apparent Power • All Phase AC Voltage • All Phase Currents • Oil Pressure • Coolant Temperature • Coolant Level • Engine Speed • Battery Voltage • Frequency Alarms and Warnings • Oil Pressure • Coolant Temperature • Coolant Level • Low Fuel Pressure • Engine Overspeed • Battery Voltage • Alarms & Warnings Time and Date Stamped • Snap Shots of Key Operation Parameters During • Alarms & Warnings • Alarms and Warnings Spelled Out (No Alarm Codes) STANDARD FEATURES 3 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency ENGINE SYSTEM ż Engine Block Heater ż Extreme Cold Weather Kit ż Oil Heater ż Air Filter Restriction Indicator ż Radiator Stone Guard (Open Set Only) ELECTRICAL SYSTEM ż 10A UL Battery Charger ż Battery Warmer FUEL SYSTEM ż NPT Flexible Fuel Line ALTERNATOR SYSTEM ż Alternator Upsizing ż Anti-Condensation Heater ż Topical Alternator Coating GENERATOR SET ż GenLink Communications Software (English Only) ż Extended Factory Testing (3-Phase Only) ż 8 Position Load Center ż Seismic Certification MAIN LINE CIRCUIT BREAKER OPTIONS ż 2nd Main Line Circuit Breaker ż Shunt Trip and Auxiliary Contact ż Electronic Trip Breakers CONTROL SYSTEM ż NFPA 110 Level 1 Compliant 21-Light Remote Annunciator ż Remote Output Relays (8 or 16) ż Oil Temperature Indication and Alarm ż Remote E-Stop (Break Glass-Type, Surface Mount) ż Remote E-Stop (Red Mushroom-Type, Surface Mount) ż Remote E-Stop (Red Mushroom-Type, Flush Mount) ż 10A Engine Run Relay ż Ground Fault Annunciator ż Damper Alarm Contacts ż 100dB Alarm Horn ż 120V GFCI and 240V Outlets ż Auxiliary Circuit Breaker Contacts to Controller ENCLOSURE ż Weather Protected Enclosure ż Level 1 Sound Attenuation ż Level 2 Sound Attenuation ż Level 2 Sound Attenuation with Motorized Dampers ż Steel Enclosure ż Aluminum Enclosure ż AC/DC Enclosure Lighting Kit ż Door Alarm Switch ż Enclosure Ambient Heaters ż Up to 200 MPH Wind Load Rating (Consult Factory for Availability) WARRANTY (Standby Gensets Only) ż 2 Year 6WDQGDUG Limited Warranty ż 5 Year Limited Warranty ż 5 Year Extended Limited Warranty ż 7 Year Extended Limited Warranty ż 10 Year Extended Limited Warranty CONFIGURABLE OPTIONS CONTROL SYSTEM ż Battery Disconnect Switch ALTERNATOR SYSTEM ż 3rd Main Line Circuit Breaker ż Unit Mounted Load Banks GENERATOR SET ż Special Testing ż Battery Box ENGINEERED OPTIONS Engine Block Heater Extreme Cold Weather Kit 10A UL Battery Charger NPT Flexible Fuel Line Topical Alternator Coating Extended Factory Testing (3-Phase Only) ż NFPA 110 Level 1 Compliant 21-Light Remote Annunciator ż Remote Output Relays (8 or 16) Remote E-Stop (Break Glass-Type, Surface Mount) 120V GFCI and 240V Outlets Level 1 Sound Attenuation Steel Enclosure 2 Yea6WDQGDUGr Limited Warranty 4 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Generac Cylinder # 8 Type V Displacement - in3 (L) 540 (8.9) Bore - in (mm) 4.49 (114.23) Stroke - in (mm) 4.25 (107.15) Compression Ratio 10.5:1 - G18 9.1:1 - G26 Intake Air Method Turbocharged/Aftercooled Number of Main Bearings 5 Cylinder Head Forged Steel Ignition High Energy Piston Type Aluminum Alloy Crankshaft Type Forged Steel Lifter Type Hydraulic Roller Intake Valve Material Steel Alloy Exhaust Valve Material Stainless Steel Hardened Valve Seats Yes Engine Governing Governor Electronic Frequency Regulation (Steady State) ±0.25% Lubrication System Oil Pump Type Gear Oil Filter Type Full-Flow Spin-On Cartridge Crankcase Capacity with Filters - L (qts) 8.5 (8.0) - G18 9.5 (10.0) - G26 Cooling System Cooling System Type Pressurized Closed Fan Type Pusher Fan Speed (rpm) 2,330 Fan Diameter - in (mm) 22 (558) Fuel System Fuel Type Natural Gas Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure NG/LPV- H2O (kPa) 7-11 (1.7- 2.7) Operating Fuel Pressure LPL- psi (kPa) 30 - 312 (206 - 2,151) Engine Electrical System System Voltage 12 VDC Battery Charger Alternator Standard Battery Size See Battery Index 0161970SBY Battery Voltage 12 VDC Ground Polarity Negative NOTE: G18 is all engines manufactured before August 3rd, 2018 . G26 is all engines manufactured after August 3rd, 2018. ALTERNATOR SPECIFICATIONS Standard Model K0130124Y21 Poles 4 Field Type Rotating Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% (3-Phase Only) Telephone Interference Factor (TIF) <50 Standard Excitation Brushless Excitation Bearings Single Sealed Coupling Direct via Flexible Disc Prototype Short Circuit Test Yes Voltage Regulator Type Full Digital Regulation Accuracy (Steady State) ±0.25% 5 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency OPERATING DATA POWER RATINGS- NATURAL GAS/PROPANE/DUAL FUEL MOTOR STARTING CAPABILITIES (skVA) FUEL CONSUMPTION RATES COOLING COMBUSTION AIR REQUIREMENTS ENGINE EXHAUST Standby Single-Phase 120/240VAC @1.0pf 130 kW Amps: 542 Three-Phase 120/208 VAC @0.8pf 130 kW Amps: 451 Three-Phase 120/240 VAC @0.8pf 130 kW Amps: 391 Three-Phase 277/480 VAC @0.8pf 130 kW Amps: 196 Three-Phase 346/600 VAC @0.8pf 130 kW Amps: 156 skVA vs. Voltage Dip 277/480 VAC 30% 208/480 VAC 30% K0130124Y21 327 K0130124Y21 327 K0150124Y21 326 K0150124Y21 244 K0200124Y21 478 K0200124Y21 361 Natural Gas – cfh (m3/hr) Propane Vapor - cfh (m3/hr) Propane Liquid- gal/hr (l/hr) Percent Load Standby Percent Load Standby Percent Load Standby 25% 635 (18.0) 25% 270 (7.6) 25% 6.5 (24.6) 50% 1,005 (28.4) 50% 390 (11.0) 50% 10.1 (38.2) 75% 1,401 (39.7) 75% 516 (14.6) 75% 14.0 (52.9) 100% 1,797 (50.9) 100% 642 (18.2) 100% 17.7 (67.0) * Fuel supply installation must accommodate fuel consumption rates at 100% load. Standby Air Flow (Fan Air Flow Across Radiator) scfm (m 3/min) 5,415 (153.3) Coolant Flow gpm (Lpm) 27.5 (104) Coolant System Capacity Gal (L) 6.34 (24.0) Max. Operating Ambient Temperature )&122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Radiator Backpressure in H2O (kPa) 0.50 (0.12) Standby Flow at Rated Power scfm (m3/min) 370.9 (10.5) Standby Standby Rated Engine Speed rpm 1,800 Exhaust Flow (Rated Output) scfm (m 3/min) 1,198 (34) Horsepower at Rated kW** hp 200- G18 205- G26 Max. Backpressure (Post Silencer) inHg (kPa) 0.75 (2.54) Piston Speed ft/min (m/min) 1,275 (389) Exhaust Temp (Rated Output - Post Silencer))&1,285 (696) BMEP psi (kPa) 166 (1145) ** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. Standby - See Bulletin - 1000001893 Three-Phase 120/208 VAC @0.8pf 130 kW Amps: 451 100%1,797 (50.9) * Fuel supply installation must accommodate fuel consumption rates at 100% load. 6 OF 6SPEC SHEETSG130 | 9.0L | 130kW INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS*† * All measurements are approximate and for estimation purposes only.† Dimensions based on unit with the Standard Model Alternator Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No 0K6449 Rev. I 06/25/18 YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER L L L LW W W W H H H H WEATHER PROTECTED ENCLOSURE L x W x H - in (mm) 132.7 (3,371) x 40.5 (1,028) x 63.1 (1,604) Weight - lbs (kg) Steel: 3,435 (1,558) Aluminum: 3,056 (1,386) LEVEL 1 ACOUSTIC ENCLOSURE L x W x H - in (mm) 154.1 (3,915) x 40.5 (1,028) x 63.1 (1,604) Weight - lbs (kg) Steel: 3,671 (1,665) Aluminum: 3,157 (1,432) LEVEL 2 ACOUSTIC ENCLOSURE L x W x H - in (mm) 144.5 (3,670) x 40.5 (1,028) x 80.0 (2,031) Weight - lbs (kg) Steel: 3,790 (1,719) Aluminum: 3,208 (1,455) OPEN SET (Includes Exhaust Flex) L x W x H - in (mm) 110.0 (2,795) x 39.9 (1,013) x 54.3 (1,379) Weight - lbs (kg) 2,674 (1,213) LEVEL 1 ACOUSTIC ENCLOSURE L x W x H - in (mm) 154.1 (3,915) x 40.5 (1,028) x 63.1 (1,604) Steel: 3,671 (1,665)Weight - lbs (kg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¡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art No. 0604160SSD Rev. E 06/13/19 GENERATOR CONTROLSThe Remote Annunciator Panel provides remote monitoring and annunciation of up to 18 generator parameters using LEDs located on the annunciator keypad. It also provides two system level warnings which are System Ready and Communications OK. The Relay Panel has up to 8 selectable functions on form A relays; multiple relay panels can be connected for all 18 generator parameters. The specific faults can be selected using either the DIP switches located on the annunciator circuit board or through a computer via the RS232 connection on the circuit board. All relays are energized on power up and open during a fault condition. Communication is via a RS485 serial data link and power is supplied by the generator battery (+12 VDC or +24 VDC). The Remote Annunciator Panel complies with NFPA 99 and NFPA 110. Environmental Specifications: Operating Temperature ................................................................................................................................................................... -25 ºC to 60 ºC Humidity .........................................................................................................................................................................0 to 95% Non-Condensing Power Supply ...........................................................................................................................................Generator Battery, +12 or +24 Volts DC Power Usage.....................................................................................................................................................................................6 WattsTypical Communication Line ..................................................................................................................RS485 Fully Isolated Twisted Pair Cable with Shield Maximum Cable Length ...............................................................................................................................................................................4,000 ft Relay Output ...........................................................................One NO Contact (Energized when Annunciator is Powered and No Faults are Present) Relay Contact Rating ............................................................................................................................................................................30 VDC, 1 A Enclosure Rating .........................................................................................................................................................................................NEMA 1 Alarm Horn (Remote Annunciator Panels Only) ...............................................................................................................................90 dB @ 10 cm Model 0054650 Gray Remote Annunciator Panel without Relays Model 0054660 Gray Remote Relay Panel without LEDs and Keypad (Relays Only) Model 0054640 Gray Remote Annunciator Panel with 8 Relays Model 0056370 Tan Flush Mount Enclosure without Annunciator Model 0066950 Gray Flush Mount Enclosure without Annunciator Description: Model 0054640 Gray Remote Annunciator Panel with 8 Relays 2 OF 2 21 LIGHT REMOTE ANNUNCIATOR AND REMOTE RELAY PANEL Part No. 0604160SSD Rev. E 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSFunction Color Alarm Latched Pre-Low Oil Pressure Yellow Yes Yes Pre-High Water Temperature Yellow Yes Yes Pre-Low Water Temperature Yellow Yes Yes Pre-Low Fuel Yellow Yes Yes Battery Charge AC Fail Yellow Yes No Low Battery Voltage Yellow Yes No High Battery Voltage Yellow No No Not in Auto Red Yes No RPM Sensor Loss Red Yes Yes Overcrank Red Yes Yes Overspeed Red Yes Yes Low Oil Pressure Red Yes Yes High Water Temperature Red Yes Yes Low Water Level Red Yes Yes Emergency Stop Red Yes No Gen Running Yellow No No Gen Power (ATS) Yellow No No Line Power (ATS) Green No No Systems Ready Green Yes No Communications OK Green Yes No Spare Green No No Surface Mount Annunciator The 21 Light Annunciator can mount to a flat surface with connections through the 0.812 inch diameter knockout on the back surface or through 0.812 inch diameter knockouts on sides as shown. Flush Mount Annunciator This Flush Mount Box is recessed into the wall opening and the surface mount annunciator mounts to the (4) 4 mm screw holes on the back surface. After wire connections are made the front annunciator cover is attached. 1.649.06 0.86 0.812 Diameter 4.53 0.812 DiameterBoth Sides11.42 10.24 7.09 8.27 9.64 Outside Four Mounting Holes for21 Light Annunciator4-mm -0.7 Female Thread 1.57 Thru 2.32 1.93 R0.59 Both Sides 0.87 1.42 6.49 Cut Rough Opening 6.75” x 9.88” 5.8 Spare Keypad Switch can be used to implement a remote start function (Model 0054640 only). Dimensions are in inches. 1 OF 2 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin No. 0182610SSD Rev. E 09/26/18 ALTERNATOR DATA SHEET K0130124Y21 60Hz ALTERNATOR DATAGeneral Characteristics Voltages (V) 208/240 and 480 Number of Leads 12 Frequency (Hz) 60 Winding Type Reconnectable Phases 3 Air Flow (cfm) 483 Speed (rpm) 1800 Total Harmonic Distortion (%) <5 Excitation System PMG/Brushless Largest Single Harmonic Value (%) <3.5 Insulation Class H Telephone Interference Factor (TIF) <50 Winding Pitch 2/3 Reference Part Number 0J1385F01R, 0L4175V01R, 0J1385E01R, 0L4175E01R Ratings at 0.8 pf based on 40ÝC Ambient Voltage (V)Ý&5LVH Ý&5LVH Ý&5LVH Ý&5LVH kW kVA kW kVA kW kVA kW kVA 208/240 99 124 119 149 130 162 140 175 480 99 124 119 149 130 162 140 175 Base Data at 480V, 162 kVA, 1800 RPM, 60 Hz, 3 Phase Description Value Stator Resistance, Line to Line, High Wye &RQQHFWLRQ0.0250 5RWRU5HVLVWDQFH2.2000 ([FLWHU6WDWRU5HVLVWDQFH30*%UXVKOHVV5.5000/6.0000 ([FLWHU5RWRU5HVLVWDQFH30*%UXVKOHVV0.5155/0.4565 ([FLWDWLRQ:LQGLQJ5HVLVWDQFH30*%UXVKOHVV1.3334/0.5042 Xd, Direct Axis Synchronous Reactance (p.u.) 2.630 X2, Negative Sequence Reactance (p.u.) 0.230 X0, Zero Sequence Reactance (p.u.) 0.030 X’d, Direct Axis Transient Reactance (p.u.) 0.180 X”d, Direct Axis Subtransient Reactance (p.u.) 0.140 Xq, Quadrature Axis Synchronous Reactance (p.u.) 1.150 T’d, Direct Axis Transient Short Circuit Time Constant (s)0.054 Description Value T”d, Direct Axis Subtransient Short Circuit Time Constant (s)0.008 T’do, Direct Axis Transient Open Circuit Time Constant (s)1.235 Ta, Short Circuit Time Constant of Armature Winding (s)0.018 Phase Sequence CCW-NDE T1, T2, T3 Voltage Balance, L-L or L-N (%) 2.5 Deviation Factor (%) 7 High Wye Connection, Sustained 3-Phase Short Circuit Current (%) - PMG only 300 X/R 7 Short Circuit Ratio 0.46 Heat Rejection (BTU/hr) - 100% Rated Load, 480V, 0.8pf, 120oC Temp. Rise 59,916 Reference: Mil-STD-705B All Ratings are Nominal 2 OF 2 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin No. 0182610SSD Rev. E 09/26/18 ALTERNATOR DATA SHEET K0130124Y21 60Hz ALTERNATOR DATAsKVA 10% 15% 20% 25% 30% 35% 480 V @ 0.3PF 77 120 169 223 292 361 480 V @ 0.6PF 94 139 192 251 327 403 208/240 V @ 0.3PF 78 120 169 223 294 365 208/240 V @ 0.6PF 89 137 192 250 327 404 Efficiencies 480 @ 0.8 PF 480 @ 1.0 PF 208/240 @ 0.8PF 208/240 @ 1.0 PF 20% Rated Power* 86.8 88.0 86.9 88.1 40% Rated Power* 89.9 92.0 90.1 92.0 60% Rated Power* 90.0 92.8 90.1 92.8 80% Rated Power* 89.3 92.6 89.1 92.5 100% Rated Power* 88.1 92.1 88.0 92.0 *Rated Power value is rating kW at 120°C Winding Temp Rise and 0.8pf LOG LOG Decrement Curve 10 100 1000 10000 100000 0.001 0.010 0.100 1.000 10.000Output Current (A)Time (s) Balanced 3-Phase Short Circuit Decrement & Thermal Damage Current Limit Curves 208V Decrement Curve 480V Decrement Curve 240V Decrement Curve 208V Thermal Damage Curve 480V Thermal Damage Curve 240V Thermal Damage Curve 208V Control System Shutdown 480V Control System Shutdown 240V Control System Shutdown 1 OF 2 GENprotect ™ Seamless Protection for Industrial Power Generators Doc. No 0187980SBY Rev. D 06/13/19 GENERATOR CONTROLSGENprotect Operation The design choice of an onsite power system using a Generac Industrial Power Generator assures your emergency power source is protected from unexpected power distribution faults. Typically, a generator will include some type of over-current device, such as a circuit breaker, or be protected by inherent design with the controller protecting the alternator through a protection algorithm. Generac’s GENprotect generator protection system monitors the system current output and protects the alternator with extended security against fault scenarios that could occur within the site’s downstream distribution system. It is a common misconception that the alternator’s main circuit breaker protects the alternator from a short circuit event. The main output breaker protects the cabling and provides a convenient disconnect. The characteristic trip curve for the industry standard thermal magnetic breaker (MCCB, molded case thermal magnetic or solid state) does not coordinate with the thermal damage limitation for an on-site generator. If circuit breakers are used for generator protection, a solid-state circuit breaker with full adjustments (Long Time, Short Time and Instantaneous, LSI) is required to coordinate the breaker protection curve within the generator thermal damage curve. Historically, this limitation was often accepted in system design since failures of the main generator feeder are extremely rare. Most short circuit events happen at a branch circuit, equipment level, where the fault is easily cleared by the smaller down stream breakers. Given the mission critical nature of today’s back-up power applications, it is more desirable to protect the system against even relatively rare failure modes. As generator controllers have become more powerful it is feasible for manufactures to supply coordinated short circuit protection integral to the generator control system, negating the need for a main-line circuit breaker. Generac’s GENprotect alternator protection algorithm monitors the generator output. If this monitoring senses short circuit current in excess of rated amps, GENprotect steps in to provide a controlled and safe approach to breaker coordination and alternator protection. GENprotect first limits the alternator short circuit current level to 300%. By limiting the available fault current, GENprotect extends the time the alternator can maintain fault current resulting in consistent breaker coordination. Without this functionality a line to neutral fault may be at 800% of rated current and need to be cleared within 1.4 seconds. The second function GENprotect performs is I2T thermal protection for the alternator. Since a short circuit event can heat the alternator so rapidly, it is not possible to protect the alternator by monitoring temperature. Instead GENprotect calculates the heat energy of the fault current. When this energy reaches the limits of NEMA MG1, GENprotect trips the generator off-line. This configuration ensures the alternator is protected and the power system is ensured 10 seconds of 300% fault current for breaker coordination. DESCRIPTION • GENprotect is an alternator protection algorithm approved by UL. • Protects alternator from damage due to shorts and electrical faults. • Provides breaker coordination and alternator protection. • Allows for use of multiple circuit breaker choices, including “no” breaker. 2 OF 2 Doc. No 0187980SBY Rev. D 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSThe above Figure shows the Generac GENprotect thermal protection curve for use in protection and coordination studies. The alternator Thermal Damage Curve is shown just to the right of the GENprotect protection curve. If the alternator load is greater than the thermal damage protection curve for the alternator, the generator set will trip off-line. For example, an overload current of 110% for 75 seconds causes an overload alarm and will trip the generator off-line, shutting down the engine. GENprotect will provide generator protection over a full range of time and current, from instantaneous faults to overloads lasting several minutes. An advantage of GENprotect over a MCCB is that GENprotect allows for downstream breakers to clear faults without tripping the generator off-line, providing selective coordination with the first level of downstream breakers. GENprotect ™ Seamless Protection for Industrial Power Generators 1 OF 1 INDUSTRIAL GENSET - BATTERY INDEX Part No. 0161970SBY Rev. K 8/02/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.BATTERY OPTIONS• Warranty by Exide Corp. • Exide e-mail: tbgna@exide.com • 800-782-7848 National Hot line Industrial Spark-Ignited Gensets - Available Batteries Engine System Voltage Battery Quantity Generac Part # 058208 (Group 24F) 077483 (Group 26) 058665 (Group 27F) 061119 (Group 31) 061104 (Group 8D) G2.4 12 1 X G4.5 12 1 X X G5.4 12 1 X X X G6.8 12 1 X X G9.0 12 1 X X G14.2 24 2 X G21.9 24 2 X G25.8 24 2 X G33.9 24 4 X X = Battery available with electrolyte and installed in genset. Industrial Diesel Gensets - Available Batteries Engine System Voltage Battery Quantity Generac Part # 058665 (Group 27F) 061119 (Group 31) 061104/BT0015A00 (Group 8D) BT0015A02 (Group 8D) D2.2 Perkins 12 1 X X D2.4 Generac 12 1 X X D3.4 Generac 12 1 X X D4.5 FPT 12 1 X D6.7 FPT 100, 130kW 12 1 or 2 †X D6.7 FPT 150, 175kW 12 2 †X D8.7 FPT 24 2 X D10.3 FPT 24 2 X X D12.9 FPT 24 2 X X D12.5 Perkins 24 2 X D15.2 Perkins 24 2 X D16.0 Volvo 24 2 X X D18.1 Perkins 24 2 X D33.9 MHI 24 2 X X D37.1 MHI 24 4 X X D49.0 MHI 24 4 X X D65.4 MHI 24 4 X X X = Battery available with electrolyte and installed in genset.† = Single or dual-paralleled battery options are available on 100 and 130kW. Single-battery option not available on 150 and 175kW. Part Number Group Number* Nominal CCA @ 0° F Dimensions (in) Nominal LWH 058208 24F 525 6.75 10.63 9.00 077483 26 525 6.75 8.25 7.75 058665 27F 700 6.75 12.50 9.00 061119 31 925 6.75 13.00 9.40 061104/ BT0015A00 8D 1,155 11.00 20.80 10.00 BT0015A02 8D 1,300 11.00 20.80 10.00 All batteries are 12V, 6 cell construction, lead calcium type. For 24V systems, batteries are wired in series. * BCI Group Size reference. ** Add an “A” suffix to the Generac part number for dry batteries, which are shipped without electrolyte. G9.0 12 1 X 061119 (Group 31) 061119 31 925 6.75 13.00 9.40 1 OF 3ENCLOSUREGENERATOR ENCLOSURES DESCRIPTION GENERAC POWER SYSTEMS’ generator enclosures provide year-round weather protection for your power equipment. Engineered with functionality and value in mind, the enclosure design benefits are unique in that the enclosures utilize dimensionally matched components for either a weather protective configuration or a sound attenuated/acoustic configuration. With common components used between design, modification and on-site upgrades can be accomplished with ease. The enclosure design offers several benefits over the “standard enclosures” of other manufacturers. Generac’s enclosures have been created with the goal of maximizing the customer’s product performance satisfaction while maintaining the functionality of reducing exterior noise levels and discouraging product tampering. Although others may require a “premium” for a self-enclosed exhaust system, rugged steel panel construction or protective polyethylene washers under all exterior panel fasteners, Generac includes these and several other features on every enclosure configuration. Be sure to compare. Generac Enclosures offer additional design enhancement extras that other “standard enclosures” do not. Doc No. 0163180SBY Rev. E 06/10/19 2 OF 3ENCLOSUREGENERATOR ENCLOSURES Post-Free Twin Doors Provide Large, Unobstructed Service Access Gasket-Free, Interconnected Roof Panel Joint Drip-Free, Maintenance-Free Heavy Gauge, Stainless Steel, Partial Pin Hinges with Nylon Spacers Durable, Corrosion-Free, Removable Doors Lockable Turn and Tuck Stainless Steel Latch Handle Corrosion-Free, Non- Protruding and Secure Dense, Closed-Cell Foam Insulation with Reflective Silver Mylar Layer Improved Sound Attenuation Without Damaging Effects From Radiant Heat Exposure Two-Point Door Latch System Ensures Proper Seal Preventing Water Ingress and Sound Egress Doc No. 0163180SBY Rev. E 06/10/19 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 3 OF 3ENCLOSURE Doc No. 0163180SBY Rev. E 06/10/19 GENERATOR ENCLOSURES FEATURES: BENEFITS: Dimensional matching of acoustic and non-acoustic enclosure designs Reduces variation in fuel tank pricing, inventory; removes need to change out fuel tank or retrofit Standardized enclosure components * Ease of retrofit or upgrade to acoustic system; reduced parts inventory, costs Enclosure mounted directly to unit baseframe Simplified delivery and installation with enclosure and unit in single component design Electrostatically painted panels Maximum protection from weather elements 12 or 14 gauge steel based on kW rating Maximum sound attenuation, protection and product life Aluminum Enclosure optional Prevents corrosion in coastal regions Stainless steel door latch and hinge hardware Provides extended component life; maximum protection against rusting Stainless steel door latch strike plate Maximum protection against enclosure paint damage from door latch pin Door hinges utilize slip-pin design Provides quick door removal for full-unit access Polyethylene gasketing under door hinges Additional protection for enclosure paint finish Keyed door latches Protection for equipment and personnel Large removable access doors Ease of maintenance Relocation of access doors Provides improved access to MLCB on all units Redesigned door gasketing Improved sealing quality from sound and weather elements Weather resistant aluminum roof design with drip ledge Provides optimum moisture/rain runoff from unit Cabled and gasketed radiator access cover Provides improved radiator access and additional protection from weather elements Acoustic roof panels manufactured with mechanical retention pins Increased acoustic foam retention within unit Polyethylene washers under all panel fasteners Additional paint finish protection from stainless steel fastener Internally fastened enclosure panels (where possible) Provides streamlined unit appearance Additional roof panel stiffener Added overall compartment rigidity and acoustic foam panel retention Self-enclosed exhaust system Provides safe unit operation; no enclosure hot spots; streamlined unit appearance Discharge air duct has been designed with minimal fasteners Ease of removal and access to exhaust system Stainless steel exhaust band clamps Provides extended component life; ensures proper exhaust seal Drain holes within air ducts Enables maximum water run-off Rodent-proof, tamper proof enclosure design Safety and security for personnel and equipment Redesigned baseframe lifting lugs Ease of unit relocation; prevents compartment damage from lifting straps Up to 200 MPH wind kit options (Contact Factory for Availability) Meets locally enforced wind requirements * Consult Generac Power Systems, Inc. for installation drawings for specific configurations and dimensions. 1 OF 1 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. RhinoCoat™ Part No. 0180230SBY Rev.D 06/18/19 UNIT OPTIONSGenerac’s RhinoCoat™ finish system provides superior durability as a standard for all Generac Industrial enclosures, tanks and frames.* Testing Standards Generac’s RhinoCoat™ finished surfaces are subjected to numerous tests. These include: • ASTM D - 1186 - 87..............................................................................................................2.5+ MIL Paint Thickness • ASTM D - 3363 - 92a............................................................................................................Adequate Material Hardness • ASTM D 522 - B....................................................................................................................Resistant To Cracking • ASTM D 3359 - B..................................................................................................................Exceptional Adhesion • ASTM B117 D 1654..............................................................................................................Resistant to Salt Water Corrosion • ASTM D1735 D 1654............................................................................................................Resistant to Humidity • ASTM 2794 93 (2004)..........................................................................................................Exceptional Impact Resistance • SAEJ1690 - UV Specifications...............................................................................................UV Protection In addition to the testing standards above, Generac adds the following test requirements more specific to generator applications: • Resistant to Typical Oils • Resistant to Typical Fuels • Resistant to Typical Antifreeze • Resistant to Distilled Water Primary codes and standards *RhinoCoat powder coat paint is durable and corrosion resistant however it is not a rust preventative. Generac pretreats all powder coated parts to assist with resistance to corrosion. 1 OF 2 EATON CIRCUIT BREAKER DATA Standard (80% Rated) Thermal-Magnetic Part No. 0189370SSD Rev. E 06/13/19 CIRCUIT BREAKERSAMPS VOLTS ACCESSORIES EATON PART No. SERIES FRAME GENERAC PART No. 15 600 No Accessories FG3015 C F-Frame 0H9294TA00 Shunt Trip & Aux. Contacts FG3015A12S03 0H9294TAB0 20 No Accessories FG3020 0H9295TA00 Shunt Trip & Aux. Contacts FG3020A12S03 0H9295TAB0 25 No Accessories FG3025 0J0248TA00 Shunt Trip & Aux. Contacts FG3025A12S03 0J0248TAB0 30 No Accessories FG3030 0H9296TA00 Shunt Trip & Aux. Contacts FG3030A12S03 0H9296TAB0 35 No Accessories FG3035 0H9297TA00 Shunt Trip & Aux. Contacts FG3035A12S03 0H9297TAB0 40 No Accessories FG3040 0H9298TA00 Shunt Trip & Aux. Contacts FG3040A12S03 0H9298TAB0 45 No Accessories FG3045 0H9299TA00 Shunt Trip & Aux. Contacts FG3045A12S03 0H9299TAB0 50 No Accessories FG3050 0H9300TA00 Shunt Trip & Aux. Contacts FG3050A12S03 0H9300TAB0 60 No Accessories FG3060 0H9301TA00 Shunt Trip & Aux. Contacts FG3060A12S03 0H9301TAB0 70 No Accessories FG3070 0H9302TA00 Shunt Trip & Aux. Contacts FG3070A12S03 0H9302TAB0 80 No Accessories FG3080 0J0841TA00 Shunt Trip & Aux. Contacts FG3080A12S03 0J0841TAB0 90 No Accessories FG3090 0J0837TA00 Shunt Trip & Aux. Contacts FG3090A12S03 0J0837TAB0 100 No Accessories FG30100 0H9314TA00 Shunt Trip & Aux. Contacts FG3100A12S03 0H9314TAB0 125 No Accessories FG30125 0J0231TA00 Shunt Trip & Aux. Contacts FG3125A12S03 0J0231TAB0 150 No Accessories FG30150 0H9315TA00 Shunt Trip & Aux. Contacts FG3150A12S03 0H9315TAB0 175 No Accessories FG30175 0H9316TA00 Shunt Trip & Aux. Contacts FG3175A12S03 0H9316TAB0 200 No Accessories FG30200 0J0232TA00 Shunt Trip & Aux. Contacts FG3200A12S03 0J0232TAB0 225 No Accessories FG3225 0H9317TA00 Shunt Trip & Aux. Contacts FG3225A12S03 0H9317TAB0 250 No Accessories JG3250 J-Frame 0H9318TA00 Shunt Trip & Aux. Contacts JG3250A12S43 0H9318TAB0 300 No Accessories KG3300 K-Frame 0H9319TA00 Shunt Trip & Aux. Contacts KG3300A12S43 0H9319TAB0 2 OF 2 Part No. 0189370SSD Rev. E 06/13/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.CIRCUIT BREAKERSEATON CIRCUIT BREAKER DATA Standard (80% Rated) Thermal-Magnetic AMPS VOLTS ACCESSORIES EATON PART # SERIES FRAME GENERAC PART # 350 600 No Accessories KG3350 C K-Frame 0H9320TA00 Shunt Trip & Aux. Contacts KG3350A12S43 0H9320TAB0 400 No Accessories KG3400 0H9321TA00 Shunt Trip & Aux. Contacts KG3400A12S43 0H9321TAB0 450 No Accessories LG3450 L-Frame 0H9322TA00 Shunt Trip & Aux. Contacts LG3450A12S03 0H9322TAB0 500 No Accessories LG3500 0H9323TA00 Shunt Trip & Aux. Contacts LG3500A12S03 0H9323TAB0 600 No Accessories LG3600 0H9324TA00 Shunt Trip & Aux. Contacts LG3600A12S03 0H9324TAB0 700 No Accessories MDL3700 M-Frame 0H9325TA00 Shunt Trip & Aux. Contacts MDL3700A06S02 0H9325TAB0 800 No Accessories MDL3800 0H9326TA00 Shunt Trip & Aux. Contacts MDL3800A06S02 0H9326TAB0 900*No Accessories NG3900 N-Frame 0H9327TA00 Shunt Trip & Aux. Contacts NG3900A12S03 0H9327TAB0 1,000*No Accessories NG31000 0H9328TA00 Shunt Trip & Aux. Contacts NG31000A12S03 0H9328TAB0 1,200*No Accessories NG31200 0H9329TA00 Shunt Trip & Aux. Contacts NG31200A12S03 0H9329TAB0 1,400*No Accessories RGH316033MY22 G RG-Frame 0H9360EAN0 Shunt Trip & Aux. Contacts RGH316033MA12S21Y22 0H9360EANB 1,600*No Accessories RGH316033MY22 0H9361EAN0 Shunt Trip & Aux. Contacts RGH316033MA12S21Y22 0H9361EANB 2,000*No Accessories RGH320033M 0H9367EAN0 Shunt Trip & Aux. Contacts RGH320033MA12S21 0H9367EANB 2,500*No Accessories RGH325033M 0H9368EAN0 Shunt Trip & Aux. Contacts RGH325033MA12S21 0H9368EANB *LS-type electronic trip breaker equipped with RMS 310+ trip unit. No Accessories KG3400 0H9321TA00400 1 OF 1 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. BATTERY CHARGER 2.5 amp and 10 amp Part No.0191900SBY Rev. E 08/12/19 GENERATOR CONTROLSThe Generac 2.5 amp 12 volt and 10 amp 12/24 volt battery chargers are designed to work with Generac Industrial Controls to provide the ultimate in automatic battery voltage maintenance. The 2.5 amp charger is self-regulating and produces instantaneous output current adjustments to keep the battery charged to an optimum level. Battery voltage is read on the control panel digital display. The 10 amp charger has automatic float and equalize control. It precisely monitors the battery’s voltage and automatically activates the correct charging mode. The charge rate is limited and controlled to efficiently and safely maintain ideal battery levels under varying conditions. The equalize system uses a control circuit to limit charging current to 10 amps. When battery voltage drops below a preset level, charging current increases to 5 amps and then to the 10 amp charge rate if needed. When the battery reaches maximum charge, the charger switches to float mode to supply just enough current to maintain the battery at or above 13/26 volts. Battery voltage and charging current are read at the control panel digital display. Battery charger shown from inside of control panel enclosure. Connections are made via an attached harness. Specifications 2.5A 10A Nominal Input 120 VAC 120 VAC Operating AC Line Voltage Range 108 to 132 VAC 108 to 132 VAC Input AC Line Frequency 50/60 Hz 50/60 Hz Battery Fuse N/A 15 A Nominal Charge Rate 2.5 A 10 A Equalize Voltage N/A 13.8/27.6 V Float Voltage 13.4 V 13.0/26.0 V Current @ Equalize to Float Transition N/A 5 A Battery Under-voltage shutdown N/A 11/22 V LED Indicators No Yes AC Line Voltage N/A Green LED Battery Connected and Charging N/A Yellow LED Battery Current Drain 30 mA 30 mA AC Line Connection Connector Plug Connector Plug Battery Connection Connector Plug Connector Plug Control Connection AC Power Fail Form Relay Form C 2 A Rating CUL Recognized Yes Yes NFPA 110 Compliant No Yes AGM Compatible No Yes UL1236 No Yes CSA 22.2 No. 107 No Yes 10A Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 1 OF 1 CIRCUIT BREAKERSPart No. 0192390SSD Rev. J 06/18/19 EATON CIRCUIT BREAKER DATA LUG INFORMATION Eaton Series C Circuit Breaker Lugs Standard Lug Amps Series Frame Eaton Part # Wire (QTY) Size 15-70 C G - (1) #10-1/0 15-100 C F 3T100FB (1) #14-1/0 125-200 C F 3TA225FD (1) #4-4/0 225 C F 3TA225FDK (1) #6-300MCM 250 C J TA250KB (1) #4-350MCM 300 C K TA350K (1) 250-500MCM 350-400 C K 3TA400K (2) 3/0-250MCM 450-500 C L TA602LD (2) 3/0-350MCM 600 C L 3TA603LDK (2) 400-500MCM 700-800 C M TA800MA2 (3) 3/0-400MCM 900-1,000 C N T1200NB3 (4) 4/0-500MCM 1,200 C N TA1201NB1 (3) 500-750MCM Eaton Series G Circuit Breaker Lugs Amps Series Frame Standard Lug Eaton Part # Wire (Qty) Size 50-250 G JG TA250FJ (1) #4-350MCM 300-600 G LG 3TA632LK (2) #2-500MCM 900-1,200 G NG TA1201NB1 (3) 500-750MCM 1,400-1,600 G RG T1600RD (4) 1-600MCM 2,000 G RG Lugs Not Included 2,500 G RG Lugs Not Included 350-400 C K 3TA400K (2) 3/0-250MCM 1 OF 1 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. ELECTRONIC GOVERNOR Spark-Ignited Engines Part No. 0604400SSD Rev. J 10/08/19 GENERATOR CONTROLSGenerac’s electronic isochronous governor systems are standard on all Spark-Ignited gensets utilizing Generac’s Digital Control Platforms. • Isochronous Speed Regulation • ±0.25% Steady State Regulation • Factory Installed and Adjusted • Fully Adjustable • Quiet-Test™ Low-Speed Exercise Capability • Fast Response • High Reliability • Environmentally Sealed Die cast enclosure housing the throttle plate and the gear-driven rotary actuator with the interior components sealed against dust, dirt and moisture. The gear drive is directly connected to the throttle plate for fast and precise control. Safety spring-return to a closed position upon loss of power. Design ..........................................................................................................................................................................................................................Bosch Type.................................................................................................................................................................................Electronically Actuated Throttle Valve Operating Voltage .....................................................................................................................................................................................................12/24VDC Response Time ........................................................................................................................................................................................................ <100 ms Operating Temperature Range ...........................................................................................................................................................................Ý)WRÝ) Output ..........................................................................................................................................................................................Rotary (internal - no linkage) ACTUATOR CONTROLLER The governor driver module is located in the generator control panel. A sealed unit with waterproof connections and a feedback circuit from the actuator for throttle plate position. Generac software controls speed governing, and is fully adjustable. The Generac electronic governor system applies to all spark-ignited gensets with Generac’s Digital Control Platforms. *(1(5$725&21752/62) 3DUW1R4*HQHUDF3RZHU6\VWHPV,QF_32%R[_:DXNHVKD:,3*HQHUDF3RZHU6\VWHPV,QF$OOULJKWVUHVHUYHG$OOVSHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH &22/$17+($7(5237,21 :$779$& >@ >@ >@ 3/$&(6 >@ >@ >@ +26(%$5%72),7µ,'+26( 3/$&(6 >@ 287/(7 ,1/(7 >@ >@ ',0(16,216PP>,1&+(6@ 63(&,),&$7,216 92/7$*(9$& +($732:(5: ),;('7+(50267$7) +($7,1*(/(0(17,1&2/2< 0$;,08035(6685(36,N3D 3/8*1(0$67'3 *(1(5$725&21752/62) 3DUW1R.%5HY%*HQHUDF3RZHU6\VWHPV,QF_32%R[_:DXNHVKD:,3*HQHUDF3RZHU6\VWHPV,QF$OOULJKWVUHVHUYHG$OOVSHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH /(9(/$&2867,&(1&/2685( 6*/ 5($5 /()7 $9(5$*( 2&7$9(%$1'&(17(5)5(48(1&<+] G%$ ',67$1&(0(7(56 0,&523+21( /2&$7,21 )5217 +]12/2$''$7$G%$ 5,*+7 $OOSRVLWLRQVDWIHHWPHWHUVIURPVLGHIDFHVRIJHQHUDWRUVHW 7HVWFRQGXFWHGRQDIRRWGLDPHWHUDVSKDXOWVXUIDFH 6RXQGSUHVVXUHOHYHOVDUHVXEMHFWWRLQVWUXPHQWDWLRQLQVWDOODWLRQDQGWHVWLQJFRQGLWLRQV $9(5$*( /()7 5($5 5,*+7 )5217 ',67$1&(0(7(56 0,&523+21( /2&$7,21 2&7$9(%$1'&(17(5)5(48(1&<+] G%$ +])8///2$''$7$G%$ )URQW 5LJKW 5HDU /HIW 5,*+7 /()7 5$(57125)1R/RDG )XOO/RDG G%$ 1 OF 2 REMOTE EMERGENCY STOP SWITCH Break Glass, H-Panel Part No. 0L6262 Rev. B 07/10/19 GENERATOR CONTROLSGenerac Part Number: 061129D Surface Mount, NEMA 3R 2 Replacement Glasses Painted Steel Enclosure Contact Rating: 10A at 120V Specifications Dimensions: mm [in]57 [2.24] 3X ø 6 [0.24] 32 [1.26] 124.5 [4.90] 140 [5.51] 120 [4.72] 120 [4.72] 93.5 [3.68] 108 [4.2] 115.5 [4.55] 1/2 - 3/4 Knockout 114 [4.49] 58 [2.3] 1/2 - 3/4 Knockout 57 [2.24] 63.5 [2.50] 31.8 [1.25] 66.7 [2.62] 33.3 [1.31] 2 OF 2 REMOTE EMERGENCY STOP SWITCH Break Glass, H-Panel Part No. 0L6262 Rev. B 07/10/19Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.GENERATOR CONTROLSWiring - H-Panel EXISTING H-PANEL INTEGRATED SWITCHHARNESS CONNECTOR H-PANEL REMOTE EXISTING ENGINE E-STOP HARNESSCONNECTORS CONNECTORHARNESS REMOTE E-STOP SHIPPED LOOSE NOTES: FACTORY WIRED JUMPER FOR TESTINGPURPOSES ONLY OR IF REMOTE E-STOP NOTPRESENT. CUSTOMER TO REMOVE WHEN INSTALLING REMOTE E-STOP E-STOP WAS ACTIVATED, BUT WILL STOP UNIT FROMRUNNING 1) THE H-PANEL REMOTE E-STOP HARNESS IS SHOWNIN POSITION BETWEEN EXISTING INTEGRATED SWITCHCONNECTOR AND ENGINE HARNESS CONNECTOR. CONNECTION POINT IS LOCATED BEHIND THE H-PANELHINGED COVER 2) SEE WIRING OR SCHEMATIC DIAGRAM(S) SPECIFIC TOUNIT FOR INFORMATION ON OTHER WIRES 3) FACTORY RUNS WIRING OUT OF H-PANEL ALONGENGINE HARNESS THAT ENTERS LOW VOLTAGE CUSTOMER CONNECTION BOX. TIE WRAP ALONG HARNESS AS NEEDED.4) THE H-PANEL WILL NOT RECOGNIZE THAT REMOTE CUSTOMER INSTALLED & WIREDWIRE TO NORMALLY CLOSEDPART OF SWITCH FACTORY WIRED VIA H-PANEL REMOTE LOCATED IN LOW VOLTAGE CUSTOMER CONNECTION BOX NEAR TB2 E-STOP HARNESS RELAY SOCKET RELAY SOCKET SWC1 SWC2 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 1 OF 1INSTALLATION Part No. 10000002132 Rev. A 03/15/16 GAS SUPPLY CHECK LIST Ƒ Gas Service Meter & Serving Utility ż Available on site & reliable ż Rated for the combined loading of the facility and the generator (total BTU). ż Maintains generator minimum pressure requirements while under maximum loading Ƒ Step Down Pressure Regulators ż Selected for the pressure & flow needs of the generator ż Direct acting type with good dynamic response (no significant time lags in regulation) ż Selected for minimum no-load to full load pressure droop (< 1-2” w.c desired) ż Located near the generator (allows the long piping runs to be at higher pressure) ż Located at least 10’ away from generator connection (avoids regulator oscillations) ż Dedicated to a single generator (increases system reliability) Ƒ Piping ż Sized large enough to minimize pressure drops to acceptable levels under full gas flow ż Minimize the number of elbows to avoid unwanted pressure drops ż Ensure entire gas supply system maintains acceptable generator pressure under full gas flow conditions ż Should be connected to generator with a flexible connection ż Should include a drip leg (sediment trap) Ƒ LP ż LP tank’s boil off rate (BTU capacity) needs to support rated BTU at minimum ambient. ż LP liquid withdrawal systems should be considered: cold ambients, small tanks, large generators ż LP liquid systems require pressure rated piping and vaporization outside a building Ƒ Generac Design Resources ż “Installation Guidelines for Stationary Industrial Generators” manual 046622 (detailed information) ż “Power Design Pro” software -- mechanical design tab (gas piping pressure drop calculator) Ƒ National Codes & Standards ż NFPA 37 “Installation and use of Stationary Combustion Engines” ż NFPA 54 “National Fuel Gas Code” ż NFPA 58 “LP Gas Code” 4321431ABAB1658[65.3]EXHAUSTOUTLET193[7.6]642 [25.3]OIL DRAIN(NOTE 7)133 [5.2]OILDRAIN101 [4.0]TYP1277 [50.3]NG FUEL INLET(NOTE 7)2795[110.0]OVERALL LENGTH1870[73.6]854[33.6]AIR DUCT(NOTE 10)1013[39.9]OVERALL WIDTH940[37.0]1379[54.3]OVERALLHEIGHT79[3.1]AIR DUCT(NOTE 10)1000[39.4]AIR DUCT(NOTE 10)117±51 [4.6±2.0]O2 SENSOR(NOTE 15, 16)1310[51.6]FLEX PIPE (NOTE 7)1072[42.2]CONNECTIONBOX HEIGHT466[18.3]CUSTOMER HIGHVOLTAGE CONNECTION(NOTE 5)688[27.1]MLCBHEIGHT710[27.9]LOW VOLTAGECONN. BOX101[4.0]LPV/LPLFUEL INLET(NOTE 7)1278[50.3]LPV/LPLFUEL INLET(NOTE 7)265[10.4]AIR DUCT(NOTE 10)DIM XCOGNOTE 6, SHEET 3DIM YCOGNOTE 6,SHEET 3DIM ZCOGNOTE 6,SHEET 3TITLEOPEN SETG9.0L 60Hz: SG13050Hz: SG104 (3 PH)STANDARD ALTISSUE DATE:SIZE CAGE NO DWG NO10000018595REVBN/A BSCALE0.035 WT-KG SHEET1 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.SH1/3REVBWINDCHILL VERSIONB.315. BLANKETS SHOULD NOT COVER OXYGEN SENSOR.16. OXYGEN SENSOR (IF EQUIPPED) MUST BE MOUNTED BETWEEN ENGINE OUTLET AND CATALYST INLET AS SHOWN. IF ELBOW IS REQUIRED ONLY SINGLE ELBOW MAY BE USED. 17. CATALYST MUST BE MOUNTED IN DESCRIBED POSITION. FAILING TO FOLLOW THESE INSTRUCTIONS WHEN INSTALLING A CERTIFIED ENGINE IN A PIECE OF STATIONARY EQUIPMENT VIOLATES FEDERAL LAW 40CFR 1068.105(b), SUBJECT TO FINES OR PENALTIES AS DESCRIBED IN THE CLEAN AIR ACT.Notes: 1. CONTROL PANEL, (OPTIONAL BATTERY CHARGER INSIDE). 2. 120V, 20A GFCI & 250V, 15A OUTLET (OPTIONAL). 3. CONNECTION POINTS FOR CONTROL WIRES PROVIDED IN THE LOW VOLTAGE CONNECTION BOX (USE LOW VOLTAGE STUB-UP AREA). 4. BATTERY (12 VOLT NEGATIVE GROUND SYSTEM). 5. MAIN LINE CIRCUIT BREAKER (MLCB), AC LOAD LEADS. (DIMENSIONS MAY VARY DUE TO UNIT CONFIGURATION) 6. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 7. ENGINE SERVICE CONNECTIONS: INLET NATURAL GAS = 2" NPT FEMALE COUPLING INLET DIESEL = N/A RETURN DIESEL = N/A OIL DRAIN = 1/2" NPT RADIATOR DRAIN = N/A FLEX PIPE OUTLET = 3" EXHAUST OUTLET = 4" INLET LPL = 1/4" NPT FEMALE COUPLING***** SEE GENERATOR SIZING GUIDE FOR FUEL PIPE SIZING TO SUIT APPLICATION ***** 8. AUXILARY AC CONNECTION FOR UNIT OPTIONS ARE LOCATED IN HIGH VOLTAGE CONNECTION BOX, UNLESS AN OPTIONAL LOAD CENTER IS INSTALLED. 9. EXHAUST PIPES MAY BE ROTATED TO ALLOW MUFFLER TO POINT OUT TO THE RIGHT OR LEFT SIDE OF GENERATOR. (MAY NOT APPLY TO ALL UNITS)10. GENERATOR SET MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND DISCHARGE AIR FROM THE RADIATOR IS NOT RECIRCULATED.11. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.12. EXHAUST SYSTEM MAXIMUM BACK PRESSUE = 10" H20, POST SILENCER.13. INSTALL EXHAUST BLANKETS ALONG THIS LINE.14. CONNECT THE OPEN SET EXHAUST PER NFPA 37ADDITIONAL NOTES: FOR WEIGHT AND CENTER OF GRAVITY DATA SEE NOTE 6, AND SHEET 3.18. BOLTS OR STUDS USED TO MOUNT UNIT TO PAD SHALL BE 5/8 - 11 GRADE 5.DIMENSIONS ARE IN MILLIMETERS [INCHES]ALT AIR OUT(BOTH SIDES)SECONDARYHIGH VOLTAGECONNECTION BOX(OPTIONAL)LOAD CENTER(OPTIONAL)LIFTING EYE(4 PLACES)51 X 80 SLOT(2.0 X 3.15)OUTLETLOCATION(NOTE 2)HIGH VOLTAGECONNECTION BOX(NOTE 8)NOTE 1LOW VOLTAGECONNECTION BOX(NOTE 3)1558 305 [61.4 12.0]O2 SENSOR TO TURBO(NOTE 13)ELBOW INCLUDED INEXHAUST KIT (NOTE 7, 9)NOTE 17NOTE 4OUTLET (NOTE 7) 4321431ABAB906 [35.7]TYP1000 [39.4]OVERALL WIDTH100 [3.9] TYP649 [25.5] TYP1297 [51.1] TYP1846 [72.7] TYP2594 [102.1] TYP2795[110.0]OVERALL LENGTH872[34.3]352 [13.8]OPEN AREAFOR STUB-UPTYP391 [15.4]TYP300[11.8]TYP27[1.1]122 [4.8] TYP120 [4.7] TYP424[16.7]235 [9.3]TYP73 [2.9]201[7.9]321[12.6]325[12.8]47 [1.9]TYP16.7 [.66]MOUNTING HOLES(10 PLACES)(SEE NOTE 18)DRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.TITLESTUB-UP VIEWG9.0L 60HZ: SG13050HZ: SG104 (3 PH)STANDARD ALTISSUE DATE:SIZE CAGE NO DWG NO10000018595REVBBSCALE0.090 WT-KG SHEET2 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUTTHE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLSH2/3REVBWINDCHILL VERSIONB.3RECOMMENDED ELECTRICAL STUB-UPHIGH VOLTAGE STUB-UPAC LOAD LEAD CONDUIT FORCONNECTION BOXLOW VOLTAGE (STUB-UP)PRIMARY CBCONNECTION BOXOPENINGSECONDARY CB CONNECTIONBOX OPENING (OPTIONAL)LOW VOLTAGE STUB-UPAREA SURFACE MOUNTED(SEE NOTE 3)DIMENSIONS ARE IN MILLIMETERS [INCHES]PRIMARY HIGH VOLTAGESTUB-UP AREASECONDARY HIGH VOLTAGESTUB-UP AREA (OPTIONAL) 4321431ABABDRAWING CREATED FROM PRO/ENGINEER3D FILE. ECO MODIFICATION TO BE APPLIED TO SOLID MODEL ONLY.TITLEWEIGHT & CENTER OF GRAVITYG9.0L 60HZ: SG13050HZ: SG104 (3 PH)STANDARD ALTISSUE DATE:SIZE CAGE NO DWG NO10000018595REVBBSCALE0.035 WT-KG SHEET3 of 3GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWINGWHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FORANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUTTHE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.c GENERAC POWER SYSTEMS 2013ELECTRONICALLY APPROVEDINSIDE WINDCHILLSH3/3REVBWINDCHILL VERSIONB.3MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG130, SG104 220V/240V 11192 KG [2628 LBS] 1645 [64.8] 536 [21.1]466 [18.3]SG/MG130, SG/MG104 208V, 240V, 400V, 480V, & 600V 31213 KG [2674 LBS] 1634 [64.3] 535 [21.0]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG130, SG104 220V/240V 11537 KG [3388 LBS] 1698 [66.9] 627 [24.7]495 [19.5]SG/MG130, SG/MG104 208V, 240V, 400V, 480V, & 600V 31558 KG [3435 LBS] 1689 [66.5] 625 [24.6]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG130, SG104 220V/240V 11644 KG [3624 LBS] 1621 [63.8] 648 [25.5]495 [19.5]SG/MG130, SG/MG104 208V, 240V, 400V, 480V, & 600V 31665 KG [3671 LBS] 1614 [63.5] 646 [25.4]MODEL VOLTAGE WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM ZSG130, SG104 220V/240V 11698 KG [3742 LBS] 1729 [68.1] 736 [29.0]495 [19.5]SG/MG130, SG/MG104 208V, 240V, 400V, 480V, & 600V 31719 KG [3790 LBS] 1721 [67.8] 733 [28.9]WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM Z1365 KG [3009 LBS] 1690 [66.5] 586 [23.1]495 [19.5]1386 KG [3056 LBS] 1680 [66.1] 584 [23.0]WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM Z1411 KG [3111 LBS] 1652 [65.0] 598 [23.5]495 [19.5]1432 KG [3157 LBS] 1642 [64.6] 596 [23.4]WEIGHTCENTER OF GRAVITYDIM XCENTER OF GRAVITYDIM YCENTER OF GRAVITYDIM Z1434 KG [3161 LBS] 1707 [67.2] 644 [25.4]495 [19.5]1455 KG [3208 LBS] 1697 [66.8] 641 [25.2]OPEN SETSTD ENCLOSURE, STEELL1A ENCLOSURE, STEELL2A ENCLOSURE, STEELSTD ENCLOSURE, ALUMINUML1A ENCLOSURE, ALUMINUML2A ENCLOSURE, ALUMINUMDIMENSIONS ARE IN MILLIMETERS [INCHES]NOTE:CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS DESIGN GUIDE FOR GENERAC INDUSTRIAL SI GENERATORS Document No. 10000046207 EdhZ>'^^hWW>z^z^dD dŚŝƐĚĞƐŝŐŶŐƵŝĚĂŶĐĞĚŽĐƵŵĞŶƚŝƐƚŽďĞƉƌŽǀŝĚĞĚƚŽƚŚĞĐŽŶƐƵůƚŝŶŐĞŶŐŝŶĞĞƌĚƵƌŝŶŐƚŚĞƉƌŽũĞĐƚĚĞƐŝŐŶƉŚĂƐĞĂŶĚ ĂŐĂŝŶĂƚƚŚĞƚŝŵĞŽĨƐƵďŵŝƚƚĂůƚŽƚŚĞĞŶŐŝŶĞĞƌĂŶĚŵĞĐŚĂŶŝĐĂůĐŽŶƚƌĂĐƚŽƌĨŽƌĂůů'ĞŶĞƌĂĐ/ŶĚƵƐƚƌŝĂůŶĂƚƵƌĂůŐĂƐ ĂŶĚƉƌŽƉĂŶĞĨƵĞůĞĚŐĞŶĞƌĂƚŽƌƐĞƚƐ͘ dŚĞĨŽůůŽǁŝŶŐƉĂŐĞƐƉƌŽǀŝĚĞŝŶĨŽƌŵĂƚŝŽŶĂŶĚĚĞƐŝŐŶďĞƐƚƉƌĂĐƚŝĐĞƐƚŚĂƚŚĂǀĞďĞĞŶĚĞŵŽŶƐƚƌĂƚĞĚƚŽŵŝŶŝŵŝnjĞŐĂƐ ƉƌĞƐƐƵƌĞŝŶƐƚĂďŝůŝƚLJĂŶĚĨůŽǁĚĞĨŝĐŝĞŶĐLJƉƌŽďůĞŵƐŝŶƚŚĞĨŝĞůĚ͘dŚĞƐĞĚĞƐŝŐŶŐƵŝĚĞůŝŶĞƐĂƌĞƚŽďĞƵƐĞĚŝŶ ĐŽŵďŝŶĂƚŝŽŶǁŝƚŚĂƉƉůŝĐĂďůĞŶĂƚŝŽŶĂůƐƚĂŶĚĂƌĚƐϭ͕ůŽĐĂůĨƵĞůŐĂƐƉŝƉŝŶŐĐŽĚĞƐ͕ĂŶĚ'ĞŶĞƌĂĐ͛Ɛ/ŶƐƚĂůůĂƚŝŽŶ'ƵŝĚĞůŝŶĞƐ ĨŽƌ^ƚĂƚŝŽŶĂƌLJ/ŶĚƵƐƚƌŝĂů'ĞŶĞƌĂƚŽƌƐ;ŽĐƵŵĞŶƚηϬϰϲϲϮϮͿ͘ ϭ͘ĞƐŝŐŶKďũĞĐƚŝǀĞƐ͗ ϭ͘ϭ͘WƌŽǀŝĚĞƚŚĞŐĞŶĞƌĂƚŽƌǁŝƚŚĂƐƚĂďůĞŐĂƐƐƵƉƉůLJƉƌĞƐƐƵƌĞŽǀĞƌǀĂƌLJŝŶŐŐĂƐĨůŽǁĚĞŵĂŶĚĐŽŶĚŝƚŝŽŶƐ͘ DĂdžŝŵƵŵŐĂƐĨůŽǁĨŽƌĂůů'ĞŶĞƌĂĐŐĞŶĞƌĂƚŽƌƐĂƌĞůŝƐƚĞĚŽŶƚŚĞƵŶŝƚŶĂŵĞƉůĂƚĞĂŶĚŐĞŶĞƌĂƚŽƌĚĂƚĂ ƐŚĞĞƚƐ͘Ϯ ϭ͘Ϯ͘dŚĞƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶĐĞŵĞĂƐƵƌĞĚĂƚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůƉƌĞƐƐƵƌĞƚĞƐƚƉŽƌƚƐŚŽƵůĚƚLJƉŝĐĂůůLJďĞůĞƐƐƚŚĂŶϮ͟ ǁĂƚĞƌĐŽůƵŵŶ;ǁ͘Đ͘ͿĨƌŽŵŶŽͲůŽĂĚƌƵŶŶŝŶŐƚŽĨƵůůͲůŽĂĚƌƵŶŶŝŶŐĐŽŶĚŝƚŝŽŶ͘ ϭ͘ϯ͘dŚĞŐĂƐƉƌĞƐƐƵƌĞŵƵƐƚƌĞŵĂŝŶĂďŽǀĞƚŚĞŵŝŶŝŵƵŵƐƉĞĐŝĨŝĞĚĨŽƌƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĂƚĂůůƚŝŵĞƐ͕ƵŶĚĞƌĂůů ŽƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͘&ĂŝůƵƌĞƚŽŵĂŝŶƚĂŝŶĂĚĞƋƵĂƚĞŐĂƐƉƌĞƐƐƵƌĞĂŶĚĨůŽǁǁŝůůƌĞƐƵůƚŝŶŽƉĞƌĂƚŝŽŶĂů ƉƌŽďůĞŵƐƐƵĐŚĂƐĞdžƚĞŶĚĞĚĐƌĂŶŬĐLJĐůĞƐ͕ŝŶĂďŝůŝƚLJƚŽĐĂƌƌLJĨƵůůůŽĂĚ͕ĂŶĚƵŶƐƚĂďůĞĞŶŐŝŶĞƐƉĞĞĚ͘ ϭ͘ϰ͘DĂŝŶƚĂŝŶĂƉƌĞƐƐƵƌĞĂŶĚĨůŽǁŵĂƌŐŝŶƚŽĂůůŽǁĨŽƌƐĞĂƐŽŶĂůƉƌĞƐƐƵƌĞǀĂƌŝĂƚŝŽŶŽŶƚŚĞƵƉƐƚƌĞĂŵŐĂƐ ƐLJƐƚĞŵ͘dŚĞĞŵĞƌŐĞŶĐLJƐLJƐƚĞŵŵƵƐƚďĞďĞĨŽƌĞƚŚĞĨĂĐŝůŝƚLJƐŚƵƚŽĨĨ͘ ϭ͘ϱ͘KƚŚĞƌĨĂĐŝůŝƚLJůŽĂĚƐŵƵƐƚďĞĨĂĐƚŽƌĞĚŝŶǁŚŝůĞƐŝnjŝŶŐƚŚĞ'ĞŶĞƌĂƚŽƌĨƵĞůƐLJƐƚĞŵ͘/ƚŝƐƌĞĐŽŵŵĞŶĚĞĚƚŚĂƚ ƚŚĞŐĞŶĞƌĂƚŽƌƐŚŽƵůĚŚĂǀĞĂĚĞĚŝĐĂƚĞĚĨƵĞůƐƵƉƉůLJ͕ǁŚŝĐŚŝƐŶŽƚƐŚĂƌĞĚǁŝƚŚĂŶLJŽƚŚĞƌĂƉƉůŝĂŶĐĞƐ ;ĨƵƌŶĂĐĞ͕ǁĂƚĞƌŚĞĂƚĞƌƐ͕ƌĂŶŐĞƐ͕ĞƚĐ͘ͿĂŶĚƚŚĞ'ĞŶĞƌĂƚŽƌĨƵĞůƐƵƉƉůLJůŝŶĞƐŚĂůůďĞŝŶƐƚĂůůĞĚĂǁĂLJĨƌŽŵĂ ŚŝŐŚŚĞĂƚƐŽƵƌĐĞƐŽƚŚĂƚƚŚĞĨƵĞůƚĞŵƉĞƌĂƚƵƌĞŵƵƐƚƌĞŵĂŝŶĂƚĂŶĂĐĐĞƉƚĂďůĞŽƉĞƌĂƚŝŶŐƌĂŐĞ͘ &ŝŐƵƌĞϭ͗dLJƉŝĐĂůŶĂƚƵƌĂůŐĂƐƐƵƉƉůLJƌĞŐƵůĂƚŽƌĂŶĚƉŝƉŝŶŐĐŽŶĨŝŐƵƌĂƚŝŽŶ͘ Ϯ͘ZĞŐƵůĂƚŽƌWĞƌĨŽƌŵĂŶĐĞƚƚƌŝďƵƚĞƐϯ͗ Ϯ͘ϭ͘ZĞŐƵůĂƚŽƌŽĚLJ^ŝnjĞ͗dŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŽƌƚƐŽŶĂƌĞŐƵůĂƚŽƌĂƌĞƚLJƉŝĐĂůůLJĂƐŝŶŐůĞŵĞƚĂůĐĂƐƚŝŶŐ͘dŚĞ ͞ďŽĚLJƐŝnjĞ͟ƌĞĨĞƌƐƚŽƚŚĞŶŽŵŝŶĂůĚŝĂŵĞƚĞƌŽĨƚŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŝƉĞƚŚƌĞĂĚƐ;ŽƌĨůĂŶŐĞͿ͘dŚĞƌĞŐƵůĂƚŽƌ ďŽĚLJƐŝnjĞƐŚŽƵůĚŶĞǀĞƌďĞůĂƌŐĞƌƚŚĂŶƚŚĞƉŝƉĞƐŝnjĞ͕ďƵƚŝƚŵĂLJďĞƐŵĂůůĞƌƉƌŽǀŝĚĞĚƚŚĞƌĞƋƵŝƌĞĚĨůŽǁĐĂŶ ďĞŽďƚĂŝŶĞĚƚŚƌŽƵŐŚƚŚĞƐŵĂůůĞƌƌĞŐƵůĂƚŽƌďŽĚLJƐŝnjĞ͘ Ϯ͘Ϯ͘WƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶƚŝĂů͗dŚĞŵĂdžŝŵƵŵĨůŽǁƌĂƚĞŽĨĂƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌŝƐĐŽŶƐƚƌĂŝŶĞĚďLJƚŚĞŐĂƐƉƌĞƐƐƵƌĞ ĚŝĨĨĞƌĞŶƚŝĂůĂĐƌŽƐƐƚŚĞŝŶůĞƚĂŶĚŽƵƚůĞƚƉŽƌƚ͘tŚĞŶƐĞůĞĐƚŝŶŐĂƌĞŐƵůĂƚŽƌĨŽƌĂƐƉĞĐŝĨŝĐŐĂƐĨůŽǁ ƌĞƋƵŝƌĞŵĞŶƚ͕ŝƚŵƵƐƚĐŽƌƌĞƐƉŽŶĚƚŽƚŚĞĞdžƉĞĐƚĞĚŶŽŵŝŶĂůƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞƐ͘ ŽŶƐƵůƚŵĂŶƵĨĂĐƚƵƌĞƌƐ͛ƉƵďůŝƐŚĞĚĨůŽǁƌĂƚĞƚĂďůĞƐĂƚǀĂƌŝŽƵƐŝŶůĞƚĂŶĚŽƵƚůĞƚƉƌĞƐƐƵƌĞǀĂůƵĞƐƚŽƐĞůĞĐƚĂŶ ĂƉƉƌŽƉƌŝĂƚĞƌĞŐƵůĂƚŽƌ;^ĞĞƚŚĞĞdžĂŵƉůĞŝŶ&ŝŐƵƌĞϮͿ͘ Ϯ͘ϯ͘&ůŽǁĂŶĚĚƌŽŽƉ͗^ĞůĞĐƚĂĚŝƌĞĐƚĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƚŚĂƚǁŝůůĚĞůŝǀĞƌĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵ ŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌǁŝƚŚϭ͟ʹϮ͟ǁĂƚĞƌĐŽůƵŵŶ;ǁ͘Đ͘ͿƉƌĞƐƐƵƌĞĚƌŽŽƉĂƚƚŚĞĞdžƉĞĐƚĞĚ ŶŽŵŝŶĂůƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞƐ͘ŝƌĞĐƚĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƐƉƌŽǀŝĚĞƚŚĞƋƵŝĐŬƌĞƐƉŽŶƐĞ ƌĞƋƵŝƌĞĚĨŽƌĐŽŶƚƌŽůůŝŶŐĨĂƐƚĐŚĂŶŐŝŶŐŐĂƐĨůŽǁĚĞŵĂŶĚƐĞŶĐŽƵŶƚĞƌĞĚŝŶĞŶŐŝŶĞͲŐĞŶĞƌĂƚŽƌĂƉƉůŝĐĂƚŝŽŶƐ͘ &ŽƌĞdžĂŵƉůĞ͕Ă'ĞŶĞƌĂĐ^'ϱϬϬŐĞŶĞƌĂƚŽƌ͕ĐŽŶĨŝŐƵƌĞĚĨŽƌϳ͟Ͳϭϭ͟ǁ͘Đ͘ŶŽŵŝŶĂůŐĂƐƉƌĞƐƐƵƌĞ͕ƌĞƋƵŝƌĞƐϲ͕ϬϬϬ &,ŽĨŐĂƐĂƚĨƵůůůŽĂĚ͘dŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌŵƵƐƚďĞƌĂƚĞĚƚŽĨůŽǁĂƉƉƌŽdžŝŵĂƚĞůLJϵ͕ϬϬϬ&,;ϭ͘ϱyϲϬϬϬ &,сϵϬϬϬ&,Ϳ͘'ŝǀĞŶĂŶƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŽĨϮƉƐŝ͕ĂϭͲϭͬϮ͟DŽĚĞůϭϮϮͲϭϮƌĞŐƵůĂƚŽƌǁŝƚŚĂďůƵĞ ƐƉƌŝŶŐǁŽƵůĚďĞƚŚĞĨŝƌƐƚĐŚŽŝĐĞ͘,ŽǁĞǀĞƌ͕ĂƐƐƵŵĞƚŚĞƌĞŝƐĂƐƵďƐƚĂŶƚŝĂůƌŝƐŬŽĨƐĞĂƐŽŶĂůƉƌĞƐƐƵƌĞ ǀĂƌŝĂƚŝŽŶǁŚĞƌĞƚŚĞƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŵĂLJĨĂůůĐůŽƐĞƌƚŽϭƉƐŝ͕ĂůĂƌŐĞƌϮ͟DŽĚĞůϭϮϮͲϭϮƌĞŐƵůĂƚŽƌ ǁŝƚŚĂďůƵĞƐƉƌŝŶŐǁŝůůƐƚŝůůƉƌŽǀŝĚĞƚŚĞƌĞƋƵŝƌĞĚĨůŽǁĂƚƚŚĞůŽǁĞƌƵƉƐƚƌĞĂŵƉƌĞƐƐƵƌĞ͘ &ŝŐƵƌĞϮ͗dLJƉŝĐĂůƌĞŐƵůĂƚŽƌĨůŽǁĐĂƉĂĐŝƚLJƚĂďůĞ͘EŽƚĞŚŽǁƚŚĞƐĂŵĞŵŽĚĞůƌĞŐƵůĂƚŽƌǁŝůůĨůŽǁůĂƌŐĞƌǀŽůƵŵĞƐ ŽĨŐĂƐǁŝƚŚĂŚŝŐŚĞƌŝŶůĞƚƉƌĞƐƐƵƌĞǁŚŝůĞŵĂŝŶƚĂŝŶŝŶŐĂƐĞƚĚŽǁŶƐƚƌĞĂŵƉƌĞƐƐƵƌĞ͘ŽƵƌƚĞƐLJŽĨ^ĞŶƐƵƐ͘ 'ĂƐƉƌĞƐƐƵƌĞƌĞŐƵůĂƚŽƌƐĂƌĞĨĞĞĚďĂĐŬĐŽŶƚƌŽůƐLJƐƚĞŵƐĚƌŝǀĞŶďLJƚŚĞƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶƚŝĂůĂĐƌŽƐƐƚŚĞ ĚŝĂƉŚƌĂŐŵĂŶĚƚŚĞĐĂƐĞƐƉƌŝŶŐ͘tŚĞŶŐĂƐĨůŽǁŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌĐĂƵƐĞƐĂ ƉƌĞƐƐƵƌĞĚƌŽƉ͕ƐƉƌŝŶŐĨŽƌĐĞŝŶƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞƉƵƐŚĞƐŽŶƚŚĞĚŝĂƉŚƌĂŐŵĂŶĚŽƉĞŶƐƚŚĞǀĂůǀĞƚŽ ŝŶĐƌĞĂƐĞŐĂƐĨůŽǁƚŽŵĂŝŶƚĂŝŶƚŚĞƐĞƚƉƌĞƐƐƵƌĞ͘dŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞŵĂŝŶƚĂŝŶĞĚďLJƚŚĞƌĞŐƵůĂƚŽƌ ĚĞĐƌĞĂƐĞƐƐůŝŐŚƚůLJĂƐŐĂƐĨůŽǁƌĂƚĞŝŶĐƌĞĂƐĞƐ;&ŝŐƵƌĞϯͿ͘dŚŝƐƉŚĞŶŽŵĞŶŽŶŝƐŬŶŽǁŶĂƐƉƌĞƐƐƵƌĞĚƌŽŽƉŽƌ͕ ŵŽƌĞƐŝŵƉůLJ͕͞ĚƌŽŽƉ͘͟ZĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌƐĚĞƐŝŐŶƉƌŽĚƵĐƚƐƚŽŵŝŶŝŵŝnjĞƉƌĞƐƐƵƌĞĚƌŽŽƉǁŚŝůĞƐƚŝůů ŵĂŝŶƚĂŝŶŝŶŐƌĞŐƵůĂƚŽƌƐƚĂďŝůŝƚLJĨŽƌĂŐŝǀĞŶŐĂƐĨůŽǁƌĂƚĞ͘ ZĞŐƵůĂƚŽƌƐƚĞŶĚƚŽĞdžŚŝďŝƚƚŚĞďĞƐƚƐƚĂďŝůŝƚLJĂŶĚƌĞƐƉŽŶƐĞƚŝŵĞǁŚĞŶƚŚĞLJŽƉĞƌĂƚĞŶĞĂƌƚŚĞŵŝĚĚůĞŽĨ ƚŚĞŝƌƉƌŽƉŽƌƚŝŽŶĂůďĂŶĚ͘^ĞůĞĐƚŝŶŐĂƌĞŐƵůĂƚŽƌǁŝƚŚĂƉƵďůŝƐŚĞĚŵĂdžŝŵƵŵŐĂƐĨůŽǁŽĨĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱ ƚŝŵĞƐƚŚĞĨƵůůͲůŽĂĚŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌĂǀŽŝĚƐŽƉĞƌĂƚŝŽŶǀĞƌLJĐůŽƐĞƚŽƚŚĞĨƵůůLJŽƉĞŶŽƌ ĨƵůůLJĐůŽƐĞĚƉŽƐŝƚŝŽŶ͕ŵŝŶŝŵŝnjŝŶŐƚŚĞƉƌŽďĂďŝůŝƚLJŽĨƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ƌĞŐƵůĂƚŽƌƚŚĂƚŝƐƚŽŽůĂƌŐĞ͕ ĐĂƉĂďůĞŽĨĨůŽǁŝŶŐƐĞǀĞƌĂůƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌ͕ǁŝůůŽƉĞƌĂƚĞǀĞƌLJ ĐůŽƐĞƚŽŝƚƐĨƵůůLJĐůŽƐĞĚƉŽƐŝƚŝŽŶǁŚŝĐŚŵĂLJĂůƐŽƌĞƐƵůƚŝŶƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ &ŝŐƵƌĞϯ͗WƌĞƐƐƵƌĞĚƌŽŽƉĐŚĂƌĂĐƚĞƌŝƐƚŝĐŽĨĂƚLJƉŝĐĂůĚŝƌĞĐƚͲŽƉĞƌĂƚĞĚƌĞŐƵůĂƚŽƌ͘ ŽƵƌƚĞƐLJŽĨŵĞƌƐŽŶͲ&ŝƐŚĞƌEĂƚƵƌĂů'ĂƐƉƉůŝĐĂƚŝŽŶ'ƵŝĚĞ͘ Ϯ͘ϰ͘^ƉƌŝŶŐZĂƚĞ͕ĐĐƵƌĂĐLJ͕ĂŶĚZĞƐƉŽŶƐĞdŝŵĞϰ͗dŚĞƌĞŐƵůĂƚŽƌƐƉƌŝŶŐƉƌŽǀŝĚĞƐƚŚĞĨŽƌĐĞƌĞƋƵŝƌĞĚƚŽŽƉĞŶ ƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞĂŶĚŵĂŝŶƚĂŝŶƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͘dŚĞƌĞŵĂLJďĞŵŽƌĞƚŚĂŶŽŶĞƐƉƌŝŶŐ ĐŽǀĞƌŝŶŐĂĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͘^ƉƌŝŶŐƐĞůĞĐƚŝŽŶƉůĂLJƐĂƌŽůĞŝŶƌĞŐƵůĂƚŽƌĂĐĐƵƌĂĐLJĂŶĚƌĞƐƉŽŶƐĞ ƚŝŵĞ͘ /ŶŐĞŶĞƌĂů͕ƵƐŝŶŐƚŚĞůŝŐŚƚĞƐƚƐƉƌŝŶŐƌĂƚĞ;ĂďůƵĞƐƉƌŝŶŐĨƌŽŵƚŚĞƉƌŝŽƌĞdžĂŵƉůĞƌĞĨĞƌĞŶĐŝŶŐ&ŝŐƵƌĞϮͿƚŚĂƚ ĂĐŚŝĞǀĞƐƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞǁŝůůƉƌŽǀŝĚĞƚŚĞďĞƐƚĂĐĐƵƌĂĐLJ͕ŵŝŶŝŵŝnjŝŶŐƉƌĞƐƐƵƌĞĚƌŽŽƉĂĐƌŽƐƐ ƚŚĞƌĂŶŐĞŽĨĞdžƉĞĐƚĞĚŐĂƐĨůŽǁƌĂƚĞƐ͘,ŽǁĞǀĞƌ͕ĂƌĞƐƉŽŶƐĞƚŚĂƚŝƐ͞ƚŽŽĨĂƐƚ͟ĐĂŶŝŶƚƌŽĚƵĐĞŽƐĐŝůůĂƚŝŽŶĂŶĚ ŝŶƐƚĂďŝůŝƚLJ͘/ĨŝŶƐƚĂďŝůŝƚLJŝƐĞdžƉĞƌŝĞŶĐĞĚĚƵƌŝŶŐŽƉĞƌĂƚŝŽŶ͕ŵŽǀŝŶŐƚŽƚŚĞŶĞdžƚŚŝŐŚĞƌƐƉƌŝŶŐ;ĂŐƌĞĞŶƐƉƌŝŶŐ ĨƌŽŵƚŚĞƉƌŝŽƌĞdžĂŵƉůĞƌĞĨĞƌĞŶĐŝŶŐ&ŝŐƵƌĞϮͿƚŚĂƚŝŶĐůƵĚĞƐƚŚĞĚĞƐŝƌĞĚŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞŝƐŽŶĞƉŽƚĞŶƚŝĂů ŵĞƚŚŽĚƚŽŵŝƚŝŐĂƚĞŽƐĐŝůůĂƚŝŽŶƐ Ϯ͘ϱ͘KƌŝĨŝĐĞƐŝnjĞ͗&ŽƌƌĞŐƵůĂƚŽƌƐǁŚĞƌĞǀĂƌŝŽƵƐŽƌŝĨŝĐĞƐŝnjĞƐĂƌĞĂǀĂŝůĂďůĞ͕ƐĞůĞĐƚƚŚĞƐŵĂůůĞƐƚŽƌŝĨŝĐĞƚŚĂƚǁŝůů ƉƌŽǀŝĚĞĂƉƉƌŽdžŝŵĂƚĞůLJϭ͘ϱƚŝŵĞƐƚŚĞŵĂdžŝŵƵŵŐĂƐĨůŽǁƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌ͘^ĞůĞĐƚŝŶŐĂŶŽƌŝĨŝĐĞ ƚŚĂƚŝƐƐŝŐŶŝĨŝĐĂŶƚůLJůĂƌŐĞƌƚŚĂŶŶĞĐĞƐƐĂƌLJǁŝůůƌĞƐƵůƚŝŶƚŚĞǀĂůǀĞŽƉĞƌĂƚŝŶŐǀĞƌLJĐůŽƐĞƚŽƚŚĞƐĞĂƚ;ŶĞĂƌůLJ ĐůŽƐĞĚͿĂŶĚŵĂLJƌĞƐƵůƚŝŶƉƌĞƐƐƵƌĞŝŶƐƚĂďŝůŝƚLJ͕ŝŶĐƌĞĂƐĞĚƐĞĂůǁĞĂƌ͕ŽƌĂƵĚŝďůĞŶŽŝƐĞĨƌŽŵƚŚĞƌĞŐƵůĂƚŽƌ͘ Ϯ͘ϲ͘>ŽĐŬƵƉŽƌŚĂƌĚƐŚƵƚŽĨĨ͗ƌĞŐƵůĂƚŽƌǁŝƚŚĂůŽĐŬƵƉŽƌŚĂƌĚƐŚƵƚŽĨĨĨĞĂƚƵƌĞŵƵƐƚďĞƵƐĞĚ͘>ŽĐŬƵƉŝƐƚŚĞ ƉƌĞƐƐƵƌĞĂďŽǀĞƚŚĞƌĞŐƵůĂƚŽƌƐĞƚƉŽŝŶƚƚŚĂƚŝƐƌĞƋƵŝƌĞĚƚŽƐŚƵƚƚŚĞƌĞŐƵůĂƚŽƌŽĨĨƚŝŐŚƚƐŽŶŽŐĂƐĨůŽǁƐ͘ dLJƉŝĐĂůůLJ͕ƚŚĞůŽĐŬƵƉƉƌĞƐƐƵƌĞŝƐϭ͟Ͳϯ͟t͘͘ĂďŽǀĞƚŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞƐĞƚƉŽŝŶƚŵĞĂƐƵƌĞĚǁŚĞŶĂƐŵĂůů ǀŽůƵŵĞŽĨŐĂƐŝƐĨůŽǁŝŶŐ;ŝ͘Ğ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐĐŽŶĚŝƚŝŽŶŽŶƚŚĞŐĞŶĞƌĂƚŽƌͿ͘dŚĞůŽĐŬƵƉĨĞĂƚƵƌĞƉƌĞǀĞŶƚƐ ƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌĨƌŽŵĐƌĞĞƉŝŶŐƵƉƚŽƚŚĞƌĞŐƵůĂƚŽƌůŝŶĞƐŝĚĞƉƌĞƐƐƵƌĞĚƵƌŝŶŐůŽŶŐ ƉĞƌŝŽĚƐŽĨnjĞƌŽŐĂƐĨůŽǁǁŚĞŶƚŚĞŐĞŶĞƌĂƚŽƌŝƐŶŽƚƌƵŶŶŝŶŐ͘/ĨĞdžĐĞƐƐŝǀĞŐĂƐƉƌĞƐƐƵƌĞŝƐĂůůŽǁĞĚƚŽďƵŝůĚ ƵƉŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͕ƚŚĞŐĞŶĞƌĂƚŽƌƐŽůĞŶŽŝĚǀĂůǀĞƐŵĂLJďĞƵŶĂďůĞƚŽŽƉĞŶ ĂŐĂŝŶƐƚƚŚĞĞdžĐĞƐƐŝǀĞƉƌĞƐƐƵƌĞĂŶĚƚŚĞĞŶŐŝŶĞǁŝůůŶŽƚƐƚĂƌƚ͘ Ϯ͘ϳ͘/ŶƚĞƌŶĂůǀƐ͘ĞdžƚĞƌŶĂůƉƌĞƐƐƵƌĞƌĞŐŝƐƚƌĂƚŝŽŶ͗/ŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐĂƌĞƌĞĐŽŵŵĞŶĚĞĚďĞĐĂƵƐĞ ƚŚĞLJŐĞŶĞƌĂůůLJŚĂǀĞĨĞǁĞƌŽƉĞƌĂƚŝŽŶĂůƉƌŽďůĞŵƐŝŶƚŚĞĨŝĞůĚ͘ &ŝŐƵƌĞϰ͗DĂũŽƌĐŽŵƉŽŶĞŶƚƐŽĨĂĚŝƌĞĐƚͲĂĐƚŝŶŐůĞǀĞƌͲƚLJƉĞƌĞŐƵůĂƚŽƌ͕ ŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚ͘ŽƵƌƚĞƐLJŵĞƌƐŽŶ&ŝƐŚĞƌ͘ dŚĞĚŝĂƉŚƌĂŐŵĐĂƐĞŽĨĂƌĞŐƵůĂƚŽƌŵƵƐƚŚĂǀĞĂĐŽŶŶĞĐƚŝŽŶƚŽƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŝŶŽƌĚĞƌƚŽĨƵŶĐƚŝŽŶ͘ /ŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐŚĂǀĞĂƉĂƐƐĂŐĞďƵŝůƚŝŶƚŽƚŚĞďŽĚLJĐĂƐƚŝŶŐǁŚŝĐŚƉƌŽǀŝĚĞƐĂƉĂƚŚĨŽƌůŽǁͲ ƉƌĞƐƐƵƌĞŐĂƐƚŽĂĐƚĂŐĂŝŶƐƚƚŚĞĚŝĂƉŚƌĂŐŵĂŶĚƐƉƌŝŶŐĨŽƌĐĞ͘džƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐůĂĐŬƚŚŝƐ ŝŶƚĞƌŶĂůĐŽŶŶĞĐƚŝŽŶƉĂƚŚďƵƚŝŶƐƚĞĂĚŚĂǀĞĂŶĂĚĚŝƚŝŽŶĂůƉŝƉĞĨŝƚƚŝŶŐŽŶƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞǁŚĞƌĞĂƐŵĂůůĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŝƐĨŝĞůĚͲĨĂďƌŝĐĂƚĞĚƚŽĂĚŽǁŶƐƚƌĞĂŵůŽĐĂƚŝŽŶŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞŵĂŝŶŐĂƐ ƉŝƉŝŶŐƐLJƐƚĞŵ͘ĞĐĂƵƐĞĂůůƚŚĞƉŝƉĞĨĂďƌŝĐĂƚŝŽŶŝƐĚŽŶĞŝŶƚŚĞĨŝĞůĚ͕ǀĂƌŝĂƚŝŽŶŝŶƚŚĞŵĂŝŶŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵ ĂŶĚƚŚĞƌĞŵŽƚĞƉƌĞƐƐƵƌĞƌĞŐŝƐƚƌĂƚŝŽŶůŝŶĞĐĂŶĐĂƵƐĞƵŶƉƌĞĚŝĐƚĂďůĞƉĞƌĨŽƌŵĂŶĐĞƚŚĂƚŝƐĚŝĨĨŝĐƵůƚƚŽ ƚƌŽƵďůĞƐŚŽŽƚ͘ džƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌƐĐĂŶďĞƵƐĞĚ͕ďƵƚƚŚĞĞŶŐŝŶĞĞƌĂŶĚŝŶƐƚĂůůĂƚŝŽŶĐŽŶƚƌĂĐƚŽƌŵƵƐƚďĞĂǁĂƌĞ ŽĨƚŚĞĚLJŶĂŵŝĐĞĨĨĞĐƚƐŝŶƚƌŽĚƵĐĞĚďLJǀĂƌŝĂďůĞƐƐƵĐŚĂƐ͖ĨůŽǁƚƵƌďƵůĞŶĐĞ͕ůĞŶŐƚŚĂŶĚĚŝĂŵĞƚĞƌŽĨƚŚĞ ƐĞŶƐŝŶŐůŝŶĞ͕ůŽĐĂƚŝŽŶŽĨƚŚĞƐĞŶƐŝŶŐƉŽŝŶƚŝŶƚŚĞůŽǁƉƌĞƐƐƵƌĞƉŝƉŝŶŐƐLJƐƚĞŵ͕ŝŶĐƌĞĂƐĞƐĂŶĚĚĞĐƌĞĂƐĞƐŝŶ ƉŝƉĞĚŝĂŵĞƚĞƌ͘ /ĨĂŶĞdžƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ůŽĐĂƚĞƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐƉŽŝŶƚϴƚŽϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐ ĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌŝŶƚŚĞůĂƌŐĞƐƚĚŝĂŵĞƚĞƌƉŝƉĞƐĞĐƚŝŽŶ͘dŚĞƐƚĂƌƚŽĨϴƚŽϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐŝƐ ĂĨƚĞƌƚŚĞƚƌĂŶƐŝƚŝŽŶƚŽƚŚĞůĂƌŐĞƐƚĚŝĂŵĞƚĞƌƉŝƉĞŽƌĂŶLJŽƚŚĞƌƚŚƌŽƚƚůŝŶŐĚĞǀŝĐĞƐ͕ĐŽŵƉŽŶĞŶƚĂŶĚͬŽƌĨŝƚƚŝŶŐƐ ƚŚĂƚǁŝůůĚŝƐƌƵƉƚĨůŽǁĂŶĚĐƌĞĂƚĞƚƵƌďƵůĞŶĐĞ͘dŚĞƐĞŶƐŝŶŐůŝŶĞƐŚŽƵůĚďĞƚĂŬĞŶŽĨĨƚŚĞƚŽƉŽĨƚŚĞŵĂŝŶůŝŶĞ ƚŽŬĞĞƉŝƚĨƌĞĞŽĨĚĞďƌŝƐĂŶĚĐŽŶĚĞŶƐĂƚĞ͘/ĨƉŽƐƐŝďůĞ͕ŝƚƐŚŽƵůĚŚŽƌŝnjŽŶƚĂůůLJƐůŽƉĞďĂĐŬƚŽƚŚĞŵĂŝŶƐŽƚŚĂƚ ĂŶLJĐŽŶĚĞŶƐĂƚĞǁŝůůĚƌĂŝŶďĂĐŬŝŶƚŽƚŚĞŵĂŝŶƌĂƚŚĞƌƚŚĂŶĂĐĐƵŵƵůĂƚĞŝŶƚŚĞƌĞŐƵůĂƚŽƌΖƐĚŝĂƉŚƌĂŐŵĐĂƐĞ͘ DŝŶŝŵŝnjĞƚŚĞĨŝƚƚŝŶŐƐƵƐĞĚŝŶƌƵŶŶŝŶŐƚŚĞƐĞŶƐŝŶŐůŝŶĞ͘ŶĞdžƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌǁŝůůƌĞƐƉŽŶĚƚŽ ƚŚĞƉƌĞƐƐƵƌĞĐŚĂŶŐĞƐƐĞŶƐĞĚĂƚƚŚĞƌĞŵŽƚĞƚĂƉƌĂƚŚĞƌƚŚĂŶǁŝƚŚŝŶƚŚĞƌĞŐƵůĂƚŽƌďŽĚLJ͘/ƚŝƐĂĚǀŝƐĂďůĞƚŽ ŝŶƐƚĂůůĂƉƌĞƐƐƵƌĞŐĂƵŐĞĂƚƚŚĞƐĞŶƐŝŶŐůŝŶĞƚĂƉŽŶƚŚĞŵĂŝŶĂƐƚŚŝƐǁŝůůďĞƚŚĞĐŽŶƚƌŽůƉŽŝŶƚŽĨƚŚĞ ƌĞŐƵůĂƚŽƌ͘ Ϯ͘ϴ͘ZĞĐŽŵŵĞŶĚĞĚŐĂƐƌĞŐƵůĂƚŽƌƐ͗ dŚĞůŝƐƚŽĨƌĞŐƵůĂƚŽƌƐďĞůŽǁŝƐŶŽƚĂŶĞdžŚĂƵƐƚŝǀĞůŝƐƚŽĨĂůůƐƵŝƚĂďůĞƌĞŐƵůĂƚŽƌƐƚŚĂƚĂƌĞĂǀĂŝůĂďůĞŝŶƚŚĞ ŵĂƌŬĞƚ͕ŶŽƌŝƐŝƚĂůŝƐƚŽĨ͞'ĞŶĞƌĂĐƉƉƌŽǀĞĚ͟ƌĞŐƵůĂƚŽƌƐ͘dŚĞůŝƐƚŝƐŝŶƚĞŶĚĞĚƚŽŚĞůƉĚĞƐŝŐŶĞŶŐŝŶĞĞƌƐĂŶĚ ŵĞĐŚĂŶŝĐĂůĐŽŶƚƌĂĐƚŽƌƐŝĚĞŶƚŝĨLJĂƌĂŶŐĞŽĨƉƌŽĚƵĐƚƐƚŚĂƚŚĂǀĞĚĞŵŽŶƐƚƌĂƚĞĚƚŚĞŝƌƐƵŝƚĂďŝůŝƚLJĨŽƌĞŶŐŝŶĞͲ ŐĞŶĞƌĂƚŽƌƐĞƌǀŝĐĞŝŶƉĂƐƚƉƌŽũĞĐƚƐ͘ŽŶƐƵůƚLJŽƵƌ'ĞŶĞƌĂĐŝƐƚƌŝďƵƚŽƌŽƌŐĂƐƌĞŐƵůĂƚŽƌƐƵƉƉůŝĞƌĨŽƌ ĂĚĚŝƚŝŽŶĂůŝŶĨŽƌŵĂƚŝŽŶ͘ Ͳ^ĞŶƐƵƐϱ ͲŵĞƌƐŽŶ&ŝƐŚĞƌ Ͳ/ƚƌŽŶ ϯ͘&ůŽǁŚĂƌĂĐƚĞƌŝƐƚŝĐƐŽĨ'ĂƐWŝƉŝŶŐ^LJƐƚĞŵƐ͗ ϯ͘ϭ͘ůďŽǁƐĂŶĚdĞĞƐ͗DŝŶŝŵŝnjĞƚŚĞŶƵŵďĞƌŽĨĞůďŽǁƐĂŶĚƚĞĞĨŝƚƚŝŶŐƐƚŚĂƚŝŶĐƌĞĂƐĞƉƌĞƐƐƵƌĞĚƌŽƉĂŶĚĨůŽǁ ƚƵƌďƵůĞŶĐĞŝŶƚŚĞƐLJƐƚĞŵ͘tŚĞƌĞŵŽƌĞƚŚĂŶƚŚƌĞĞĞůďŽǁƐĂŶĚͬŽƌƚĞĞƐĂƌĞƌĞƋƵŝƌĞĚ͕ƵƐĞŽĨƐǁĞƉƚƌĂĚŝƵƐ ĞůďŽǁƐ;ƚLJƉŝĐĂůĨŽƌǁĞůĚĞĚƉŝƉĞƐĞĐƚŝŽŶƐͿǁŝůůŚĞůƉƌĞĚƵĐĞƉƌĞƐƐƵƌĞůŽƐƐ͘ ϯ͘Ϯ͘ZĞĚƵĐŝŶŐďƵƐŚŝŶŐƐ;ƐǁĂŐĞƐͿ͗WŝƉĞƌĞĚƵĐŝŶŐďƵƐŚŝŶŐƐĂƌĞƚŚĞƚƌĂŶƐŝƚŝŽŶĨƌŽŵĂůĂƌŐĞƌƚŽƐŵĂůůĞƌƉŝƉĞ ĚŝĂŵĞƚĞƌŽƌǀŝĐĞǀĞƌƐĂ͘'ĂƐĨůŽǁǀĞůŽĐŝƚLJŝƐƐůŽǁĞƌŝŶĂůĂƌŐĞƌĚŝĂŵĞƚĞƌƉŝƉĞĐŽŵƉĂƌĞĚƚŽĂƐŵĂůůĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŵŽǀŝŶŐƚŚĞƐĂŵĞǀŽůƵŵĞŽĨŐĂƐ͘/ĨĂƌĞŵŽƚĞƐĞŶƐŝŶŐƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ŝƚŝƐŝŵƉŽƌƚĂŶƚƚŽ ƵŶĚĞƌƐƚĂŶĚƚŚĞĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞĞĨĨĞĐƚƐĐĂƵƐĞĚďLJƚŚĞŐĂƐĨůŽǁǀĞůŽĐŝƚŝĞƐŝŶĚŝĨĨĞƌĞŶƚƐŝnjĞĚƉŝƉĞƐĞĐƚŝŽŶƐ ĂŶĚĚĞƐŝŐŶĂĐĐŽƌĚŝŶŐůLJ͘ϲ /ŶƐŽŵĞŝŶƐƚĂůůĂƚŝŽŶƐǁŚĞƌĞŝƚŝƐŝŵƉƌĂĐƚŝĐĂůƚŽƌƵŶĂƉƉƌŽdžŝŵĂƚĞůLJϭϬĨĞĞƚŽĨƉŝƉĞ͕ƐǁĂŐŝŶŐƵƉƚŽĂůĂƌŐĞƌ ĚŝĂŵĞƚĞƌƉŝƉĞŝƐĂƉƌĂĐƚŝĐĂůŵĞƚŚŽĚƚŽŝŶĐƌĞĂƐĞƚŚĞŐĂƐǀŽůƵŵĞďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůƐLJƐƚĞŵ͘&ŽƌŝŶƐƚĂůůĂƚŝŽŶƐǁŚĞƌĞƚŚŝƐŵĞƚŚŽĚŝƐƵƐĞĚ͕ĂŶŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐ ƐƚƌŽŶŐůLJƌĞĐŽŵŵĞŶĚĞĚ͘ ϯ͘ϯ͘&ůĞdžŝďůĞĨƵĞůůŝŶĞƐ͗&ůĞdžŝďůĞĨƵĞůůŝŶĞƐĂƌĞŝŶƚĞŶĚĞĚƚŽŝƐŽůĂƚĞƚŚĞƌŝŐŝĚŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵĨƌŽŵǀŝďƌĂƚŝŽŶƐŽŶ ƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĂŶĚŵƵƐƚďĞŝŶƐƚĂůůĞĚĂƐƐƚƌĂŝŐŚƚĂƐƉŽƐƐŝďůĞ͘dŚĞLJĂƌĞŶŽƚŝŶƚĞŶĚĞĚƚŽĐŽƌƌĞĐƚ ŵŝƐĂůŝŐŶĞĚƉŝƉĞƐĞĐƚŝŽŶƐŽƌƚŽƐĞƌǀĞĂƐĂŶĞůďŽǁ͘ ϯ͘ϰ͘ZĞŐƵůĂƚŽƌǀĞŶƚůŝŶĞƐ͗ZĞŐƵůĂƚŽƌǀĞŶƚƐŵƵƐƚŽƉĞŶĚŽǁŶǁĂƌĚĂŶĚďĞƐĐƌĞĞŶĞĚƚŽƉƌĞǀĞŶƚŝŶƐĞĐƚƐĂŶĚ ǁĂƚĞƌĨƌŽŵĞŶƚĞƌŝŶŐƚŚĞƌĞŐƵůĂƚŽƌĐĂƐĞ͘ZĞŐƵůĂƚŽƌǀĞŶƚůŝŶĞƐƐŚŽƵůĚďĞŬĞƉƚĂƐƐŚŽƌƚĂƐƉŽƐƐŝďůĞƚŽƌĞĚƵĐĞ ƚŚĞƉŽƐƐŝďŝůŝƚLJŽĨĂĨĨĞĐƚŝŶŐƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞƚŝŵĞ͘ ϰ͘ĞƐŝŐŶZĞƋƵŝƌĞŵĞŶƚƐ͗ ϰ͘ϭ͘hƐĞ'ĞŶĞƌĂĐ͛ƐWŽǁĞƌĞƐŝŐŶWƌŽϳŐĂƐƉŝƉĞƐŝnjŝŶŐŵŽĚƵůĞƚŽĚĞƚĞƌŵŝŶĞƚŚĞŵŝŶŝŵƵŵƌĞĐŽŵŵĞŶĚĞĚƉŝƉĞ ƐŝnjĞĨŽƌƚŚĞƐĞůĞĐƚĞĚŐĞŶĞƌĂƚŽƌ͛ƐŐĂƐĨůŽǁŐŝǀĞŶƚŚĞĂŶƚŝĐŝƉĂƚĞĚůĞŶŐƚŚŽĨƚŚĞƉŝƉĞƌƵŶďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞ ƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚ͕ŝŶĐůƵĚŝŶŐĂůůĞůďŽǁƐ͘^ĞůĞĐƚƚŚĞŽƉƚŝŽŶƚŽĚĞƐŝŐŶĨŽƌфϬ͘ϱ͟ǁĂƚĞƌ ĐŽůƵŵŶƉƌĞƐƐƵƌĞĚƌŽƉ͘ZĞĨĞƌƚŽƚŚĞdĂďůĞϭĨŽƌŵŽƌĞĚĞƚĂŝů͘ ϰ͘Ϯ͘dŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞƐŚĂůůďĞŝŶƐƚĂůůĞĚĂƚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚůŽĐĂƚĞĚŽŶƚŚĞĨƌĂŵĞƌĂŝůĂŶĚŵƵƐƚĞdžŝƚ ƚŚĞŐĞŶĞƌĂƚŽƌƉĞƌƉĞŶĚŝĐƵůĂƌƚŽƚŚĞĨƌĂŵĞƌĂŝů͘EŽƉŝƉĞĨŝƚƚŝŶŐƐ;ĞůďŽǁƐŽƌƐǁĂŐĞƐͿĂƌĞƉĞƌŵŝƚƚĞĚďĞƚǁĞĞŶ ƚŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚƉŽƌƚ͘ ϰ͘ϯ͘dŚĞĨůĞdžŝďůĞĨƵĞůůŝŶĞŵƵƐƚďĞĂƐƐƚƌĂŝŐŚƚĂƐƉŽƐƐŝďůĞ͘/ƚŝƐĚĞƐŝŐŶĞĚƚŽŝƐŽůĂƚĞƚŚĞƌŝŐŝĚŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵ ĨƌŽŵǀŝďƌĂƚŝŽŶƐŽŶƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚ͘/ƚŝƐŶŽƚŝŶƚĞŶĚĞĚƚŽĐŽƌƌĞĐƚŵŝƐĂůŝŐŶĞĚƉŝƉĞƐĞĐƚŝŽŶƐŽƌƚŽƐĞƌǀĞĂƐ ĂŶĞůďŽǁ͘ ϰ͘ϰ͘'ŝǀĞŶƚŚĞĐŽŵďŝŶĞĚĞĨĨĞĐƚƐŽĨƉŝƉĞĨƌŝĐƚŝŽŶůŽƐƐĂŶĚƌĞŐƵůĂƚŽƌĚƌŽŽƉ͕ŐĂƐƉƌĞƐƐƵƌĞƐŚŽƵůĚƚLJƉŝĐĂůůLJŶŽƚ ĚƌŽƉŵŽƌĞƚŚĂŶϮ͟ǁ͘Đ͘ĨƌŽŵŶŽͲůŽĂĚƌƵŶŶŝŶŐƚŽĨƵůůͲůŽĂĚƌƵŶŶŝŶŐ͘hŶĚĞƌŶŽĐŝƌĐƵŵƐƚĂŶĐĞƐƐŚĂůůƚŚĞŐĂƐ ƉƌĞƐƐƵƌĞŵĞĂƐƵƌĞĚĂƚƚŚĞƚĞƐƚƉŽƌƚŽŶƚŚĞŝŶƐŝĚĞĨƌĂŵĞƌĂŝůŽĨƚŚĞŐĞŶĞƌĂƚŽƌƐĞƚĚƌŽƉďĞůŽǁƚŚĞŵŝŶŝŵƵŵ ƌĂƚĞĚŐĂƐƉƌĞƐƐƵƌĞůŝƐƚĞĚŽŶƚŚĞŐĞŶĞƌĂƚŽƌŶĂŵĞƉůĂƚĞ͘ ϰ͘ϱ͘&ƵůůͲƉŽƌƚďĂůůǀĂůǀĞƐ͕ƚŚĞƐĂŵĞĚŝĂŵĞƚĞƌĂƐƚŚĞƉŝƉĞǁŚŝĐŚƚŚĞLJĂƌĞĐŽŶŶĞĐƚĞĚƚŽ͕ĂƌĞƚŽďĞƵƐĞĚĨŽƌĂůů ƐŚƵƚͲŽĨĨƐ͘ ϰ͘ϲ͘&ŽƌŵƵůƚŝƉůĞŐĞŶĞƌĂƚŽƌƐĞƚŝŶƐƚĂůůĂƚŝŽŶƐ;'ĞŶĞƌĂĐDW^Ϳ͕ĞĂĐŚŐĞŶĞƌĂƚŽƌƐĞƚŵƵƐƚŚĂǀĞŝƚƐŽǁŶƌĞŐƵůĂƚŽƌ ŝŶƐƚĂůůĞĚ͘ŽŶŽƚƐŚĂƌĞĂƐŝŶŐůĞůĂƌŐĞƌĞŐƵůĂƚŽƌĂĐƌŽƐƐŵƵůƚŝƉůĞŐĞŶĞƌĂƚŽƌƐĞƚƐ͘ ϱ͘ZĞĐŽŵŵĞŶĚĞĚĞƐŝŐŶĞƐƚWƌĂĐƚŝĐĞƐ͗ ϱ͘ϭ͘WƌŽǀŝĚĞĂƉƉƌŽdžŝŵĂƚĞůLJϭϬĨĞĞƚŽĨƉŝƉĞďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚŐĞŶĞƌĂƚŽƌŐĂƐŝŶůĞƚ͘dŚŝƐĚŽĞƐŶŽƚŚĂǀĞ ƚŽďĞĂƐŝŶŐůĞƐƚƌĂŝŐŚƚƌƵŶ͘dŚĞƉŝƉĞǀŽůƵŵĞĚĞĐŽƵƉůĞƐƚŚĞĚLJŶĂŵŝĐƌĞƐƉŽŶƐĞŽĨƚŚĞŐĞŶĞƌĂƚŽƌƚŚƌŽƚƚůĞ ĐŽŶƚƌŽůƐLJƐƚĞŵĂŶĚƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌ͕ƌĞĚƵĐŝŶŐƚŚĞƉƌŽďĂďŝůŝƚLJŽĨŽƐĐŝůůĂƚŝŽŶĂŶĚƵŶƐƚĂďůĞŽƉĞƌĂƚŝŽŶ͘ ϱ͘Ϯ͘ǀŽŝĚŝŶƐƚĂůůŝŶŐĞůďŽǁƐŽƌƉŝƉĞƐǁĂŐĞƐŝŵŵĞĚŝĂƚĞůLJƵƉƐƚƌĞĂŵŽƌĚŽǁŶƐƚƌĞĂŵŽĨĂƌĞŐƵůĂƚŽƌ͕ƵŶůĞƐƐ ƐƉĞĐŝĨŝĐĂůůLJĂůůŽǁĞĚďLJƚŚĞƌĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌ͘dŚŝƐǁŝůůŝŶĐƌĞĂƐĞƚŚĞƚƵƌďƵůĞŶĐĞŽĨƚŚĞŐĂƐĨůŽǁ͕ ŚĂǀŝŶŐĂŶĞŐĂƚŝǀĞŝŵƉĂĐƚŽŶƉƌĞƐƐƵƌĞƌĞŐƵůĂƚŝŽŶĂĐĐƵƌĂĐLJĂŶĚƐƚĂďŝůŝƚLJ͘ZĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌƐƚLJƉŝĐĂůůLJ ƌĞĐŽŵŵĞŶĚϭϬƉŝƉĞĚŝĂŵĞƚĞƌƐŽĨƐƚƌĂŝŐŚƚƉŝƉĞƌƵŶƵƉƐƚƌĞĂŵĂŶĚĚŽǁŶƐƚƌĞĂŵŽĨĂƌĞŐƵůĂƚŽƌ͘&Žƌ ĞdžĂŵƉůĞ͕ŽŶĂƌĞŐƵůĂƚŽƌǁŝƚŚϮ͟ĚŝĂŵĞƚĞƌƉŝƉĞĨŝƚƚŝŶŐƐ͕ϮϬ͟ŽĨƐƚƌĂŝŐŚƚƉŝƉĞƐŚŽƵůĚďĞĨŝƚƚĞĚƵƉƐƚƌĞĂŵĂŶĚ ĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘tŚĞŶĨŝĞůĚĐŽŶĚŝƚŝŽŶƐƉƌŽŚŝďŝƚŵĞĞƚŝŶŐďŽƚŚĐŽŶƐƚƌĂŝŶƚƐ͕ƉůĂĐĞƚŚĞĞůďŽǁ ŽŶƚŚĞŚŝŐŚͲƉƌĞƐƐƵƌĞƐŝĚĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘dŚĞƐƚƌĂŝŐŚƚƌƵŶŽŶƚŚĞůŽǁͲƉƌĞƐƐƵƌĞƐŝĚĞŝƐŵŽƌĞĐƌŝƚŝĐĂůĨŽƌ ƉƌŽƉĞƌƌĞŐƵůĂƚŽƌŽƉĞƌĂƚŝŽŶ͘ ϱ͘ϯ͘ǀŽŝĚŝŶƐƚĂůůŝŶŐƉŝƉĞƐǁĂŐĞƐŝŵŵĞĚŝĂƚĞůLJďĞĨŽƌĞŽƌĂĨƚĞƌĂŶĞůďŽǁ͘dŚĞĐŽŵďŝŶĞĚĨůŽǁƚƵƌďƵůĞŶĐĞŽĨƚŚĞ ƐǁĂŐĞĂŶĚĞůďŽǁŝŶĐůŽƐĞƉƌŽdžŝŵŝƚLJĐĂŶĐĂƵƐĞƵŶĞdžƉĞĐƚĞĚůLJůĂƌŐĞƉƌĞƐƐƵƌĞĚƌŽƉƐĂƚŚŝŐŚĨůŽǁƌĂƚĞƐ͘ ϱ͘ϰ͘DŝŶŝŵŝnjĞƚŚĞŶƵŵďĞƌŽĨϵϬͲĚĞŐƌĞĞĞůďŽǁƐ͘/ĨŵŽƌĞƚŚĂŶƚŚƌĞĞĞůďŽǁƐĂƌĞŶĞĞĚĞĚĚŽǁŶƐƚƌĞĂŵŽĨƚŚĞ ƌĞŐƵůĂƚŽƌƚŽĂĐĐŽŵŵŽĚĂƚĞƚŚĞĚĞƐŝŐŶ͕ƐǁĞƉƚƌĂĚŝƵƐĞůďŽǁƐĂƌĞƌĞĐŽŵŵĞŶĚĞĚƚŽŵŝŶŝŵŝnjĞƉƌĞƐƐƵƌĞĚƌŽƉ͘ ϱ͘ϱ͘hƐĞŽĨĂŶŝŶƚĞƌŶĂůůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƐƚƌŽŶŐůLJƌĞĐŽŵŵĞŶĚĞĚ͘ZĞŐƵůĂƚŽƌƐǁŝƚŚĞdžƚĞƌŶĂůƉƌĞƐƐƵƌĞ ƌĞŐŝƐƚƌĂƚŝŽŶůŝŶĞƐĂĚĚĂŶĂĚĚŝƚŝŽŶĂůǀĂƌŝĂďůĞŝŶƚŽƚŚĞƐLJƐƚĞŵƚŚĂƚĐĂŶďĞĚŝĨĨŝĐƵůƚƚŽƚƌŽƵďůĞƐŚŽŽƚƐŚŽƵůĚ ƚŚĞŐĂƐƉƌĞƐƐƵƌĞďĞĐŽŵĞƵŶƐƚĂďůĞƵŶĚĞƌŚŝŐŚͲĨůŽǁĐŽŶĚŝƚŝŽŶƐ͘ ϱ͘ϲ͘&ŽƌŵŽƌĞƐƚĂďůĞŐĂƐĨůŽǁǁŝƚŚůŽŶŐĞƌŐĂƐƉŝƉŝŶŐ͕ƚŚĞŚŝŐŚƉƌĞƐƐƵƌĞƐŝĚĞŵĂLJďĞƌĂŝƐĞĚĂƐŚŝŐŚĂƐĐŽĚĞ ĂůůŽǁƐĂŶĚƌĞŐƵůĂƚĞŝƚĚŽǁŶƚŽŐĞŶĞƌĂƚŽƌŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞĂƚƚŚĞŐĞŶĞƌĂƚŽƌ͘;dŚŝƐŝƐƚŚĞƐĂŵĞĚĞƐŝŐŶ ĐŽŶĐĞƉƚƵƐĞĚŝŶƚŚĞĞůĞĐƚƌŝĐĂůŝŶĚƵƐƚƌLJ͖͞ŚŝŐŚǀŽůƚĂŐĞĨŽƌůŽŶŐĚŝƐƚĂŶĐĞƐ͕ƚƌĂŶƐĨŽƌŵĂƚŝŽŶĂƚƚŚĞ ůŽĂĚƐ͟Ϳ͘dŚŝƐŵĂLJĂůƐŽŚĞůƉƌĞĚƵĐĞĐŽƐƚĂƐƉŝƉĞĚŝĂŵĞƚĞƌƐĐĂŶďĞƐŵĂůůĞƌ͕ƐĂǀŝŶŐŵĂƚĞƌŝĂůĂŶĚŝŶƐƚĂůůĂƚŝŽŶ ĐŽƐƚƐ͘ ϲ͘/ŶƐƚĂůůĂƚŝŽŶĂŶĚŽŵŵŝƐƐŝŽŶŝŶŐZĞĐŽŵŵĞŶĚĂƚŝŽŶƐ͗ ϲ͘ϭ͘ZĞĨĞƌƚŽ'ĞŶĞƌĂĐ͛Ɛ/ŶƐƚĂůůĂƚŝŽŶ'ƵŝĚĞůŝŶĞƐĨŽƌ^ƚĂƚŝŽŶĂƌLJ/ŶĚƵƐƚƌŝĂů'ĞŶĞƌĂƚŽƌƐ;ŽĐƵŵĞŶƚηϬϰϲϲϮϮͿĨŽƌ ĂĚĚŝƚŝŽŶĂůŝŶƐƚĂůůĂƚŝŽŶĚĞƚĂŝůƐ͘ ϲ͘Ϯ͘WŝŐĂůůŐĂƐƉŝƉĞƐĂĨƚĞƌŝŶƐƚĂůůĂƚŝŽŶƚŽƌĞŵŽǀĞƉŝƉĞĚŽƉĞ͕ǁĞůĚƐůĂŐĂŶĚŽƚŚĞƌĐŽŶƚĂŵŝŶĂŶƚƐƚŚĂƚĐŽƵůĚ ĚĂŵĂŐĞƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞƐĞĂƚĂŶĚĐĂƵƐĞƉƌĞƐƐƵƌĞĐƌĞĞƉ͘ ϲ͘ϯ͘/ŶƐƚĂůůĂĚŝƌƚƚƌĂƉĂŶĚͬŽƌƐĐƌĞĞŶďĞĨŽƌĞƚŚĞŐĂƐƌĞŐƵůĂƚŽƌ͘ ϲ͘ϰ͘^ĞƚƚŚĞƌĞŐƵůĂƚŽƌƉƌĞƐƐƵƌĞǁŝƚŚƚŚĞŐĞŶĞƌĂƚŽƌƌƵŶŶŝŶŐĂƚŶŽͲůŽĂĚ͘DĞĂƐƵƌĞŵĞŶƚƐĂƌĞƚĂŬĞŶĂƚƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůƉƌĞƐƐƵƌĞƚĞƐƚƉŽƌƚŽŶƚŚĞŝŶƐŝĚĞŽĨƚŚĞĨƌĂŵĞƌĂŝů͘&ŽƌƵŶŝƚƐĐŽŶĨŝŐƵƌĞĚĨŽƌϳ͟Ͳϭϭ͟ǁ͘Đ͘ ŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͕ƐĞƚƚŚĞƌĞŐƵůĂƚŽƌƚŽϭϭ͟ǁ͘Đ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐ͘&ŽƌƵŶŝƚƐĐŽŶĨŝŐƵƌĞĚĨŽƌϭϭͲϭϰ͟ǁ͘Đ͘ ŽƉĞƌĂƚŝŶŐƉƌĞƐƐƵƌĞ͕ƐĞƚƚŚĞƌĞŐƵůĂƚŽƌƚŽϭϰ͟ǁ͘Đ͘ŶŽͲůŽĂĚƌƵŶŶŝŶŐ͘WƌĞƐƐƵƌĞĚƌŽŽƉĂƚĨƵůůͲůŽĂĚƌƵŶŶŝŶŐǁŝůů ďĞĂĐŽŵďŝŶĂƚŝŽŶŽĨƌĞŐƵůĂƚŽƌĚƌŽŽƉĂŶĚƉŝƉĞĨƌŝĐƚŝŽŶůŽƐƐ͘WƌŽƉĞƌĚĞƐŝŐŶǁŝůůůŝŵŝƚƚŚĞŶŽͲůŽĂĚƚŽĨƵůůͲůŽĂĚ ƌƵŶŶŝŶŐƉƌĞƐƐƵƌĞĚƌŽƉƚŽŶŽŵŽƌĞƚŚĂŶϮ͟ǁ͘Đ͘ĂŶĚĂƚŶŽƚŝŵĞĐĂŶƚŚĞŐĂƐƉƌĞƐƐƵƌĞĨĂůůďĞůŽǁƚŚĞ ŵŝŶŝŵƵŵƉƌĞƐƐƵƌĞůŝƐƚĞĚŽŶƚŚĞŐĞŶĞƌĂƚŽƌŶĂŵĞƉůĂƚĞ͘džƉĞĐƚƚŚĞůŽĐŬƵƉƐƚĂƚŝĐƉƌĞƐƐƵƌĞƚLJƉŝĐĂůůLJƚŽďĞ ŚŝŐŚĞƌƚŚĂŶƚŚĞŶŽͲůŽĂĚƌƵŶŶŝŶŐĚLJŶĂŵŝĐƉƌĞƐƐƵƌĞ͘ ϳ͘DĞƚŚŽĚƐĨŽƌĐŽƌƌĞĐƚŝŶŐƵŶĚĞƐŝƌĂďůĞƉĞƌĨŽƌŵĂŶĐĞ͗ ϳ͘ϭ͘WƌĞƐƐƵƌĞƐƵƌŐŝŶŐĂŶĚĐLJĐůŝŶŐ͗^ŚŽƵůĚƚŚĞƌĞŐƵůĂƚŽƌĞdžƉĞƌŝĞŶĐĞ͞ŚƵŶƚŝŶŐ͟ŽƌŽƚŚĞƌƵŶƐƚĂďůĞŽƉĞƌĂƚŝŶŐ ďĞŚĂǀŝŽƌ͕ĂŶĞdžƚĞŶĚĞĚǀĞŶƚůŝŶĞŵĂLJďĞĐƌĞĂƚŝŶŐƌĞƐŽŶĂŶƚĐŽŶĚŝƚŝŽŶŽŶƚŚĞĂƚŵŽƐƉŚĞƌŝĐƐŝĚĞŽĨƚŚĞ ƌĞŐƵůĂƚŽƌĚŝĂƉŚƌĂŐŵ͘/ĨƚŚŝƐŝƐƐƵƐƉĞĐƚĞĚ͕ƚĞŵƉŽƌĂƌŝůLJĚŝƐĐŽŶŶĞĐƚƚŚĞǀĞŶƚůŝŶĞŽƌƌĞŵŽǀĞƚŚĞĐĂƉĨƌŽŵƚŚĞ ƌĞŐƵůĂƚŽƌƐƉƌŝŶŐĐĂƐĞĂŶĚŽďƐĞƌǀĞŝĨƚŚĞƵŶƐƚĂďůĞďĞŚĂǀŝŽƌƐƚŽƉƐ͘^ŚŽƌƚĞŶŝŶŐƚŚĞůĞŶŐƚŚŽƌŝŶĐƌĞĂƐŝŶŐƚŚĞ ĚŝĂŵĞƚĞƌŽĨƚŚĞǀĞŶƚůŝŶĞǁŝůůŽĨƚĞŶĐŽƌƌĞĐƚĂŶŝŶƐƚĂďŝůŝƚLJĐĂƵƐĞĚďLJǀĞŶƚůŝŶĞƌĞƐŽŶĂŶĐĞ͘ dŚĞƉŝƉĞǀŽůƵŵĞďĞƚǁĞĞŶƚŚĞƐĞƌǀŝĐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌŵĂLJďĞŝŶƐƵĨĨŝĐŝĞŶƚƚŽĚĞĐŽƵƉůĞƚŚĞ ĐŽŶƚƌŽůĂĐƚŝŽŶŽĨƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌ͛ƐƚŚƌŽƚƚůĞĐŽŶƚƌŽůƐLJƐƚĞŵ͘/ŶĐƌĞĂƐĞƚŚĞƉŝƉĞǀŽůƵŵĞ ďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌ͘ ŚĂŶŐĞƚŚĞƌĞƐƉŽŶƐĞƚŝŵĞŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘/ŶƐŽŵĞĐĂƐĞƐ͕ĂƐŵĂůůĂĚũƵƐƚŵĞŶƚŽĨƚŚĞƌĞŐƵůĂƚŽƌƐƉƌŝŶŐ;ƵƉ ŽƌĚŽǁŶϭǁ͘Đ͘ͿǁŝůůďĞĞŶŽƵŐŚƚŽƌĞƐƚŽƌĞƐƚĂďŝůŝƚLJƚŽƚŚĞƐLJƐƚĞŵ͘/ĨĂǀĂŝůĂďůĞĨŽƌƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌ͕ ƵƐŝŶŐƚŚĞŶĞdžƚŚŝŐŚĞƌƐƉƌŝŶŐŝƐĂŶŽƚŚĞƌŝŶĞdžƉĞŶƐŝǀĞĂŶĚĞĂƐLJƚŽŝŵƉůĞŵĞŶƚŽƉƚŝŽŶ͘dŚŝƐǁŝůůƐůŽǁƚŚĞ ƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞĂŶĚĐĂŶƌĞĚƵĐĞŽƌĞůŝŵŝŶĂƚĞƚŚĞŝŶƐƚĂďŝůŝƚLJ͘<ĞĞƉŝŶŵŝŶĚƚŚĂƚĐŚĂŶŐŝŶŐƚŽĂŚŝŐŚĞƌ ƐƉƌŝŶŐƌĂƚĞǁŝůůĂůƐŽŝŶĐƌĞĂƐĞƉƌĞƐƐƵƌĞĚƌŽŽƉĂŶĚƌĞĚƵĐĞƚŚĞƌĞŐƵůĂƚŽƌ͛ƐŵĂdžŝŵƵŵĨůŽǁĐĂƉĂĐŝƚLJǁŚŝĐŚ ůŝŵŝƚƐƚŚĞĂƉƉůŝĐĂďŝůŝƚLJŽĨƚŚŝƐĐŽƌƌĞĐƚŝǀĞŵĞĂƐƵƌĞ͘ ϳ͘Ϯ͘>ŽǁŐĂƐƉƌĞƐƐƵƌĞƵŶĚĞƌŚŝŐŚůŽĂĚ͗dŚĞƌĞĂƌĞƐĞǀĞƌĂůƉŽƚĞŶƚŝĂůĐĂƵƐĞƐŽĨůŽǁŐĂƐƉƌĞƐƐƵƌĞƵŶĚĞƌŚŝŐŚ ůŽĂĚ͘ WŝƉĞƌƵŶƐǁŝƚŚĞdžĐĞƐƐŝǀĞĨƌŝĐƚŝŽŶůŽƐƐĐĂƵƐĞĚďLJĂƉŝƉĞĚŝĂŵĞƚĞƌƚŚĂƚŝƐƚŽŽƐŵĂůůĨŽƌƚŚĞƌĞƋƵŝƌĞĚŐĂƐĨůŽǁ ĂŶĚƉŝƉĞůĞŶŐƚŚĂŶĚͬŽƌĂůĂƌŐĞŶƵŵďĞƌŽĨĞůďŽǁƐ͘dŚĞŽŶůLJĐŽƌƌĞĐƚŝǀĞĂĐƚŝŽŶĨŽƌƚŚŝƐŝƐƚŽŝŶĐƌĞĂƐĞƚŚĞ ƉŝƉĞĚŝĂŵĞƚĞƌďĞƚǁĞĞŶƚŚĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌŽƌƚŽƌĂŝƐĞƚŚĞƉƌĞƐƐƵƌĞŽĨƚŚĞŚŝŐŚƉƌĞƐƐƵƌĞŐĂƐ͘ ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƵƐŝŶŐĂŐĂƐƉŝƉĞƐŝnjŝŶŐƚŽŽůĚƵƌŝŶŐƚŚĞĚĞƐŝŐŶƉŚĂƐĞ͘ /ŶƐƵĨĨŝĐŝĞŶƚƌĞŐƵůĂƚŽƌĐĂƉĂĐŝƚLJ͘ŽŶĨŝƌŵƚŚĞƵƉƐƚƌĞĂŵŐĂƐŵĂŝŶĂŶĚƌĞŐƵůĂƚŽƌĨůŽǁĐĂƉĂďŝůŝƚŝĞƐĨŽƌĂŐŝǀĞŶ ƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞ͘/ĨƚŚĞƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŝƐůŽǁĞƌƚŚĂŶŽƌŝŐŝŶĂůůLJĂŶƚŝĐŝƉĂƚĞĚ͕ŝŶǀĞƐƚŝŐĂƚĞƚŚĞ ƉŽƐƐŝďŝůŝƚLJĂĚũƵƐƚŝŶŐƚŚĞƵƚŝůŝƚLJƌĞŐƵůĂƚŽƌ;ŝĨƉƌĞƐĞŶƚͿ͘/ĨŝŶĐƌĞĂƐŝŶŐƵƉƐƚƌĞĂŵŐĂƐƉƌĞƐƐƵƌĞŝƐŶŽƚƉŽƐƐŝďůĞ͕Ă ůĂƌŐĞƌŽƌŝĨŝĐĞĂŶĚͬŽƌĚŝĨĨĞƌĞŶƚƐƉƌŝŶŐĐŽŵďŝŶĂƚŝŽŶŵĂLJďĞĂǀĂŝůĂďůĞĨŽƌƚŚĞĞdžŝƐƚŝŶŐƌĞŐƵůĂƚŽƌƚŽŝŶĐƌĞĂƐĞ ĨůŽǁĂŶĚƌĞĚƵĐĞƉƌĞƐƐƵƌĞĚƌŽŽƉ͘/ĨƚŚĞƉƌĞǀŝŽƵƐƐƚĞƉƐĨĂŝůƚŽĐŽƌƌĞĐƚƚŚĞƐŝƚƵĂƚŝŽŶ͕ĂůĂƌŐĞƌƌĞŐƵůĂƚŽƌǁŝůů ďĞƌĞƋƵŝƌĞĚ͘ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƚŚŽƌŽƵŐŚůLJƌĞǀŝĞǁŝŶŐƚŚĞƌĞŐƵůĂƚŽƌŵĂŶƵĨĂĐƚƵƌĞƌ͛ƐĨůŽǁƌĂƚĞƚĂďůĞƐ ƉƌŝŽƌƚŽŽƌĚĞƌŝŶŐ͘ ϳ͘ϯ͘džĐĞƐƐŝǀĞƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚƌŽƉĚƵƌŝŶŐŐĞŶĞƌĂƚŽƌĐƌĂŶŬĐLJĐůĞŽƌďůŽĐŬůŽĂĚĂƉƉůŝĐĂƚŝŽŶ͗/ĨƚŚĞƚƌĂŶƐŝĞŶƚ ƉƌĞƐƐƵƌĞĚƌŽƉĚƵƌŝŶŐĂŐĞŶĞƌĂƚŽƌĐƌĂŶŬĐLJĐůĞŽƌďůŽĐŬůŽĂĚĂƉƉůŝĐĂƚŝŽŶŝƐůĂƌŐĞĞŶŽƵŐŚƚŽŝŵƉĂĐƚ ƉĞƌĨŽƌŵĂŶĐĞ͕ƐƉĞĞĚŝŶŐƵƉƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞǁŝůůƌĞĚƵĐĞƚŚĞƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚƌŽƉ͘ǀŽŝĚƚŚŝƐ ƉƌŽďůĞŵďLJƵƐŝŶŐĂĚŝƌĞĐƚͲĂĐƚŝŶŐƌĞŐƵůĂƚŽƌƚŚĂƚŝƐƐƵŝƚĂďůĞĨŽƌĞŶŐŝŶĞͲŐĞŶĞƌĂƚŽƌĂƉƉůŝĐĂƚŝŽŶƐ͘/ĨĂǀĂŝůĂďůĞ ĨŽƌƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌ͕ƵƐŝŶŐĂůŝŐŚƚĞƌƐƉƌŝŶŐǁŝůůŝŶĐƌĞĂƐĞƚŚĞƌĞŐƵůĂƚŽƌƌĞƐƉŽŶƐĞƐƉĞĞĚĂŶĚƌĞĚƵĐĞ ƚƌĂŶƐŝĞŶƚƉƌĞƐƐƵƌĞĚŝƉ͘&ŝŶĂůůLJ͕ŝĨĂƌĞŵŽƚĞůLJƌĞŐŝƐƚĞƌĞĚƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ŝŶĐƌĞĂƐĞƚŚĞƉŝƉĞĚŝĂŵĞƚĞƌŽĨ ƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐůŝŶĞ͘ ϳ͘ϰ͘WƌĞƐƐƵƌĞĐƌĞĞƉ͗ŶƐƵƌĞƚŚĞƐĞůĞĐƚĞĚƌĞŐƵůĂƚŽƌŚĂƐĂůŽĐŬƵƉŽƌŚĂƌĚͲƐŚƵƚŽĨĨĨĞĂƚƵƌĞ͘WƌĞƐƐƵƌĞĐƌĞĞƉŝƐ ĂůŵŽƐƚĂůǁĂLJƐĐĂƵƐĞĚďLJĐŽŶƚĂŵŝŶĂŶƚƐŝŶƚŚĞƉŝƉĞƐLJƐƚĞŵƵƉƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘dŚĞĐŽŶƚĂŵŝŶĂŶƚƐ ĞŝƚŚĞƌŐĞƚĐĂƵŐŚƚŽŶƚŚĞƌĞŐƵůĂƚŽƌǀĂůǀĞĚŝƐŬŽƌĐĂƵƐĞƉŚLJƐŝĐĂůĚĂŵĂŐĞƚŽƚŚĞǀĂůǀĞĚŝƐŬ͕ŵĂŬŝŶŐŝƚ ŝŵƉŽƐƐŝďůĞƚŽĂĐŚŝĞǀĞĂŚĂƌĚƐŚƵƚŽĨĨ͘ǀŽŝĚƚŚŝƐƉƌŽďůĞŵďLJƉŝŐŐŝŶŐĂůůƉŝƉĞĐŽŵƉŽŶĞŶƚƐƉƌŝŽƌƚŽŝŶƐƚĂůůŝŶŐ ƚŚĞƌĞŐƵůĂƚŽƌĂŶĚĞŶƐƵƌĞĂĚŝƌƚƚƌĂƉŝƐŝŶƐƚĂůůĞĚƵƉƐƚƌĞĂŵŽĨƚŚĞƌĞŐƵůĂƚŽƌ͘ ϳ͘ϱ͘&ĂŝůƵƌĞƚŽƐƚĂƌƚ͕ƌƵŶƐŵŽŽƚŚůLJ͕ŽƌĂĐĐĞƉƚϭϬϬйůŽĂĚ͗ĂƌƌŝŶŐĂŵĞĐŚĂŶŝĐĂůĨĂŝůƵƌĞŽŶƚŚĞŐĞŶĞƌĂƚŽƌ͕ĨĂŝůƵƌĞ ƚŽŵĂŬĞϭϬͲƐĞĐŽŶĚƐƚĂƌƚ͕ƌƵŶƐŵŽŽƚŚůLJ͕ŽƌĐĂƌƌLJĨƵůůůŽĂĚŝƐĂůŵŽƐƚĂůǁĂLJƐĐĂƵƐĞĚďLJĂŶƵŶĚĞƌůLJŝŶŐŐĂƐ ƐƵƉƉůLJƉƌŽďůĞŵ͘ ϴ͘WƌŽƉĂŶĞsĂƉŽƌĂŶĚ>ŝƋƵŝĚ͗ ϴ͘ϭ͘WƌŽƉĂŶĞǀĂƉŽƌƐLJƐƚĞŵ͗dŚŝƐƚLJƉĞŽĨƐLJƐƚĞŵƵƐĞƐƚŚĞǀĂƉŽƌƐĨŽƌŵĞĚĂďŽǀĞƚŚĞůŝƋƵŝĚĨƵĞůŝŶƚŚĞƐƵƉƉůLJ ƚĂŶŬ͘dŚĞŵĂdžŝŵƵŵƚĂŶŬůŝƋƵŝĚĐĂƉĂĐŝƚLJŝƐϴϬйĂŶĚĂŵŝŶŝŵƵŵŽĨĂƉƉƌŽdžŝŵĂƚĞůLJϮϬйŽĨƚŚĞƚĂŶŬĐĂƉĂĐŝƚLJ ŝƐƌĞƋƵŝƌĞĚƚŽďŽŝůŽĨĨůŝƋƵŝĚŝŶƚŽƚŚĞǀĂƉŽƌƐƚĂƚĞ͘'ĂƐƉƌĞƐƐƵƌĞĂŶĚǀŽůƵŵĞƌĞƋƵŝƌĞŵĞŶƚƐĨŽƌĂŶ>W' ƐLJƐƚĞŵĂƚƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽĨƚŚĞŐĞŶĞƌĂƚŽƌĂƌĞůŝƐƚĞĚŽŶƚŚĞƵŶŝƚƐƉĞĐŝĨŝĐĂƚŝŽŶƐŚĞĞƚ͘dŚĞƉŝƉŝŶŐ ƐLJƐƚĞŵĐŽŶŶĞĐƚŝŶŐƚŚĞŽƵƚůĞƚŽĨƚŚĞĨŝƌƐƚƐƚĂŐĞƌĞŐƵůĂƚŽƌƚŽƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽŶƚŚĞƐĞĐŽŶĚƐƚĂŐĞ ƌĞŐƵůĂƚŽƌŵƵƐƚďĞƉƌŽƉĞƌůLJƐŝnjĞĚƚŽƉƌŽǀŝĚĞƚŚĞĨƵĞůǀŽůƵŵĞƌĞƋƵŝƌĞĚďLJƚŚĞƵŶŝƚĂƚϭϬϬйůŽĂĚ͘ dŚĞƉŝƉŝŶŐƐLJƐƚĞŵďĞƚǁĞĞŶƚŚĞŽƵƚůĞƚŽĨƚŚĞƐĞĐŽŶĚƐƚĂŐĞƌĞŐƵůĂƚŽƌĂŶĚƚŚĞŐĞŶĞƌĂƚŽƌĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚ ŵƵƐƚďĞƐŝnjĞĚƚŽƉƌŽǀŝĚĞƚŚĞĨƵĞůǀŽůƵŵĞƌĞƋƵŝƌĞĚďLJƚŚĞŐĞŶĞƌĂƚŽƌĂƚϭϬϬйůŽĂĚǁŚŝůĞĂůƐŽƐƚĂLJŝŶŐ ǁŝƚŚŝŶƚŚĞƉƌĞƐƐƵƌĞƌĂŶŐĞŶŽƚĞĚŽŶƚŚĞƵŶŝƚƐƉĞĐŝĨŝĐĂƚŝŽŶƐŚĞĞƚ͘ ϴ͘Ϯ͘dĂŶŬǀĂƉŽƌŝnjĂƚŝŽŶƌĂƚĞ͗/ŶĂĚĚŝƚŝŽŶƚŽƐŝnjŝŶŐƚŚĞŐĂƐƉŝƉŝŶŐƐLJƐƚĞŵŝŶĂƐŝŵŝůĂƌŵĂŶŶĞƌƚŽŶĂƚƵƌĂůŐĂƐ͕>WͲ ǀĂƉŽƌƐLJƐƚĞŵƐŵƵƐƚĂůƐŽƐŝnjĞƚŚĞƉƌŽƉĂŶĞƐƚŽƌĂŐĞƚĂŶŬƐƚŽĞŶƐƵƌĞĂƐƵĨĨŝĐŝĞŶƚǀŽůƵŵĞŽĨŐĂƐǁŝůůďŽŝůŽĨĨ ƵŶĚĞƌĂƌĂŶŐĞŽĨĞŶǀŝƌŽŶŵĞŶƚĂůĐŽŶĚŝƚŝŽŶƐĂŶĚǀĂƌŝŽƵƐůŝƋƵŝĚůĞǀĞůƐŝŶƚŚĞƚĂŶŬ͘>ŝƋƵŝĚƉƌŽƉĂŶĞĂďƐŽƌďƐ ĂŵďŝĞŶƚŚĞĂƚĨƌŽŵƚŚĞƐƵƌƌŽƵŶĚŝŶŐĞŶǀŝƌŽŶŵĞŶƚƚŽďŽŝůŽĨĨůŝƋƵŝĚŝŶƚŽĂŐĂƐ͘>ŽǁůŝƋƵŝĚůĞǀĞůƐŝŶĂƚĂŶŬ ĐŽƵƉůĞĚǁŝƚŚĐŽůĚĂŵďŝĞŶƚƚĞŵƉĞƌĂƚƵƌĞƐĐĂŶƌĞƐƵůƚŝŶĂĐŽŶĚŝƚŝŽŶǁŚĞƌĞƚŚĞƚĂŶŬďŽŝůŽĨĨƌĂƚĞŝƐ ŝŶƐƵĨĨŝĐŝĞŶƚƚŽŵĞĞƚƚŚĞĚĞŵĂŶĚƐŽĨƚŚĞŐĞŶĞƌĂƚŽƌ͘ dŚĞůŽĐĂůƉƌŽƉĂŶĞƐƵƉƉůŝĞƌŝƐŽĨƚĞŶĂŐŽŽĚƌĞƐŽƵƌĐĞƚŽŚĞůƉǁŝƚŚƚĂŶŬƐŝnjŝŶŐ͘dŚĞŵĞƌƐŽŶͲ&ŝƐŚĞƌ>WͲ'ĂƐ ^ĞƌǀŝĐĞŵĂŶ͛Ɛ,ĂŶĚŬŝƐĂŶŽƚŚĞƌǀĂůƵĂďůĞƌĞƐŽƵƌĐĞĨŽƌƐŝnjŝŶŐƉƌŽƉĂŶĞƐLJƐƚĞŵƐĂŶĚŝŶĐůƵĚĞƐƚĂŶŬ ǀĂƉŽƌŝnjĂƚŝŽŶƚĂďůĞƐ͘ϴ/ŶŵĂŶLJĐĂƐĞƐ͕ƚŚĞƚĂŶŬǀŽůƵŵĞŵƵƐƚďĞůĂƌŐĞƌ;ƐŽŵĞƚŝŵĞƐŵƵĐŚůĂƌŐĞƌͿƚŚĂŶƚŚĞ ŐĂƐƌĞƋƵŝƌĞĚƚŽĂĐŚŝĞǀĞĂĚĞƐŝƌĞĚƌƵŶƚŝŵĞ͘tŚĞƌĞƉƌĂĐƚŝĐĂů͕ďƵƌŝĞĚƚĂŶŬƐĐĂŶŝŵƉƌŽǀĞƚŚĞǀĂƉŽƌŝnjĂƚŝŽŶ ƌĂƚĞďLJƉƌŽƚĞĐƚŝŶŐƚŚĞƚĂŶŬĨƌŽŵĞdžƚƌĞŵĞůLJůŽǁĂŵďŝĞŶƚĂŝƌƚĞŵƉĞƌĂƚƵƌĞƐ͘ &ŝŐƵƌĞϲ͗ďŽǀĞŐƌŽƵŶĚD^dĂŶŬǀĂƉŽƌŝnjĂƚŝŽŶ ƌĂƚĞ͕>WͲ'ĂƐ^ĞƌǀŝĐĞŵĂŶΖƐ,ĂŶĚŬ͘ ϴ͘ϯ͘>ŝƋƵŝĚƉƌŽƉĂŶĞƐLJƐƚĞŵ͗dŚŝƐƐLJƐƚĞŵĚĞůŝǀĞƌƐƉƌŽƉĂŶĞŝŶĂůŝƋƵŝĚƐƚĂƚĞ;>W>ͿƚŽƚŚĞĐŽŶŶĞĐƚŝŽŶƉŽŝŶƚŽŶƚŚĞ ŐĞŶĞƌĂƚŽƌƐĞƚ͘>ŝƋƵŝĚƉƌŽƉĂŶĞƐLJƐƚĞŵƐĂƌĞƵƐĞĚǁŚĞƌĞŝƚŝƐŝŵƉƌĂĐƚŝĐĂůƚŽĂĐŚŝĞǀĞƚŚĞƌĞƋƵŝƌĞĚďŽŝůŽĨĨ ƌĂƚĞĨƌŽŵƚŚĞĂǀĂŝůĂďůĞĨƵĞůƚĂŶŬǀŽůƵŵĞ͘&ŽƌƚŚĞĞŶŐŝŶĞƚŽƵƐĞƚŚĞ>W>ĨƵĞů͕ƚŚĞůŝƋƵŝĚŵƵƐƚďĞǀĂƉŽƌŝnjĞĚ ƉƌŝŽƌƚŽďĞŝŶŐĚĞůŝǀĞƌĞĚƚŽƚŚĞĨƵĞůŵŝdžĞƌ;ĐĂƌďƵƌĞƚŽƌͿ͘>W>ǁŝůůǀĂƉŽƌŝnjĞĂƚĂƚĞŵƉĞƌĂƚƵƌĞŽĨ;ͲϰϰΣ&ͬͲ ϰϮ͘ϮΣͿ͘dŚĞŐĞŶĞƌĂƚŽƌƐĞƚ>W>ĨƵĞůƐLJƐƚĞŵĚĞůŝǀĞƌLJƉƌĞƐƐƵƌĞŽƉĞƌĂƚĞƐŽǀĞƌƚŚĞƌĂŶŐĞŽĨϱϴͲϭϴϬƉƐŝ;ϰϬϬͲ ϭϮϰϮŬWĂͿ͕ĚĞƉĞŶĚŝŶŐŽŶƚŚĞĂŵďŝĞŶƚƚĞŵƉĞƌĂƚƵƌĞĂŶĚůŝƋƵŝĚůĞǀĞůŝŶƚŚĞƐƚŽƌĂŐĞƚĂŶŬ͘>W>ĞŶƚĞƌƐƚŚĞ ǀĂƉŽƌŝnjĞƌĂŶĚƉĂƐƐĞƐŝŶƚŽĂ͞ĨůĂƐŚ͟ĐŚĂŵďĞƌ͘dŚĞƉƌĞƐƐƵƌĞĚƌŽƉŝŶƚŚŝƐĐŚĂŵďĞƌǀĂƉŽƌŝnjĞƐƚŚĞůŝƋƵŝĚƚŽĂ ŐĂƐĂŶĚŝƐƌĞŐƵůĂƚĞĚƚŽϭϭ͟Ͳϭϰ͟ǁ͘Đ͘;Ϯ͘ϵͲϯ͘ϱŬWĂͿ͘,ĞĂƚĞĚĞŶŐŝŶĞĐŽŽůĂŶƚĨƌŽŵƚŚĞũĂĐŬĞƚǁĂƚĞƌŚĞĂƚĞƌŝƐ ƵƐĞĚƚŽŚĞĂƚƚŚĞĨůĂƐŚĐŚĂŵďĞƌŽĨƚŚĞǀĂƉŽƌŝnjĞƌĂŶĚƚŽƉƌĞǀĞŶƚƚŚĞǀĂƉŽƌŝnjĞƌĨƌŽŵŝĐŝŶŐ͘ ƚŚĞƉƌŝŵĂƌLJƐŽƵƌĐĞŵĂLJŶŽƚďĞĂǀĂŝůĂďůĞĚƵƌŝŶŐĂƉŽǁĞƌŽƵƚĂŐĞ͘ƵĂůĨƵĞůƐLJƐƚĞŵƐƵƐĞŶĂƚƵƌĂůŐĂƐĂƐƚŚĞ ƉƌŝŵĂƌLJĨƵĞůĂŶĚ>W'Žƌ>W>ǁŝƚŚĚƌĂǁĂůĂƐƚŚĞƐĞĐŽŶĚĂƌLJĨƵĞů͘&ŽƌĚƵĂůĨƵĞůƵŶŝƚƐ͕ƚŚĞƐƉĞĐŝĨŝĐĨƵĞů ϴ͘ϰ͘ƵĂůĨƵĞů͕ŶĂƚƵƌĂůŐĂƐƉƌŝŵĂƌLJĂŶĚƉƌŽƉĂŶĞƐĞĐŽŶĚĂƌLJ͗^ŽŵĞĂƉƉůŝĐĂƚŝŽŶƐƵƐĞĂĚƵĂůĨƵĞůƐLJƐƚĞŵǁŚĞƌĞ ƉƌĞƐƐƵƌĞ͕ǀŽůƵŵĞ͕ĂŶĚƉŝƉĞƐŝnjŝŶŐƌĞƋƵŝƌĞŵĞŶƚƐĨŽƌĞĂĐŚĨƵĞůƚLJƉĞŵƵƐƚďĞŽďƐĞƌǀĞĚ͘ ϵ͘ĚĚŝƚŝŽŶĂůƌĞƐŽƵƌĐĞƐ͗ ϭE&Wϯϳ͞/ŶƐƚĂůůĂƚŝŽŶĂŶĚƵƐĞŽĨ^ƚĂƚŝŽŶĂƌLJŽŵďƵƐƚŝŽŶŶŐŝŶĞƐ͟ E&Wϱϰ͞EĂƚŝŽŶĂů&ƵĞů'ĂƐŽĚĞ͟ E&Wϱϴ͞>W'ĂƐŽĚĞ͟ &ƌĞĞĂĐĐĞƐƐƚŽǀŝĞǁE&WĐŽĚĞĚŽĐƵŵĞŶƚƐĐĂŶďĞĨŽƵŶĚĂƚ͗ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ŶĨƉĂ͘ŽƌŐͬŽĚĞƐͲĂŶĚͲ^ƚĂŶĚĂƌĚƐͬůůͲŽĚĞƐͲĂŶĚͲ^ƚĂŶĚĂƌĚƐͬ&ƌĞĞͲĂĐĐĞƐƐ͘ ϮĂƚĂƐŚĞĞƚƐĨŽƌ'ĞŶĞƌĂĐ/ŶĚƵƐƚƌŝĂůŐĂƐŐĞŶĞƌĂƚŽƌƐĞƚƐ͗ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ŐĞŶĞƌĂĐ͘ĐŽŵͬ/ŶĚƵƐƚƌŝĂůͬƉƌŽĚƵĐƚƐͬŐĂƐĞŽƵƐͲŐĞŶĞƌĂƚŽƌƐ͘ ϯŵŽƌĞƚŚŽƌŽƵŐŚĚĞƐĐƌŝƉƚŝŽŶŽĨƚŚĞŽƉĞƌĂƚŝŽŶĂůƉƌŝŶĐŝƉůĞƐĂŶĚƉĞƌĨŽƌŵĂŶĐĞĂƚƚƌŝďƵƚĞƐŽĨŐĂƐƌĞŐƵůĂƚŽƌƐĐĂŶďĞ ĨŽƵŶĚŝŶŵĞƌƐŽŶͲ&ŝƐŚĞƌ͛ƐEĂƚƵƌĂů'ĂƐƉƉůŝĐĂƚŝŽŶ'ƵŝĚĞĂƚ͗ ŚƚƚƉ͗ͬͬǁǁǁ͘ĞŵĞƌƐŽŶ͘ĐŽŵͬĞŶͲƵƐͬĂƵƚŽŵĂƚŝŽŶͬǀĂůǀĞƐͲĂĐƚƵĂƚŽƌƐͲƌĞŐƵůĂƚŽƌƐͬƌĞŐƵůĂƚŽƌƐ͘ ϰĂƵƐĞƐĂŶĚƵƌĞƐŽĨZĞŐƵůĂƚŽƌ/ŶƐƚĂďŝůŝƚLJ͕ůĂƐƐηϲϬϭϬ͘tŝůůŝĂŵ,ĂƌŶĞLJ͕&ŝƐŚĞƌŽŶƚƌŽůƐ/ŶƚĞƌŶĂƚŝŽŶĂů/ŶĐ͘ϭϵϵϱ͘ ŚƚƚƉƐ͗ͬͬǁǁǁ͘ƐĐƌŝďĚ͘ĐŽŵͬĚŽĐƵŵĞŶƚͬϭϵϳϲϱϯϴϰϭͬĂƵƐĞƐͲĂŶĚͲƵƌĞƐͲŽĨͲZĞŐƵůĂƚŽƌͲ/ŶƐƚĂďŝůŝƚLJ ϱ^ĞŶƐƵƐƉƌŽĚƵĐƚĚĂƚĂƐŚĞĞƚƐ͗ŚƚƚƉƐ͗ͬͬƐĞŶƐƵƐ͘ĐŽŵͬƉƌŽĚƵĐƚƐ͍ͬƵƚŝůŝƚLJсŐĂƐ ϲdŚĞĞƌŶŽƵůůŝĨĨĞĐƚǁŝůůĐĂƵƐĞĂĚŝĨĨĞƌĞŶĐĞŝŶŐĂƐƉƌĞƐƐƵƌĞŽŶůLJǁŚĞŶŐĂƐŝƐĨůŽǁŝŶŐ͘tŚĞŶĂƌĞŵŽƚĞƐĞŶƐŝŶŐ ƌĞŐƵůĂƚŽƌŝƐƵƐĞĚ͕ĂŶĚƚŚĞƌĞŵŽƚĞƐĞŶƐŝŶŐƉŽŝŶƚŝƐůŽĐĂƚĞĚŝŶĂƉŝƉĞƐĞĐƚŝŽŶƚŚĂƚŝƐĂůĂƌŐĞƌĚŝĂŵĞƚĞƌƚŚĂŶƚŚĞ ŐĞŶĞƌĂƚŽƌĨƵĞůŝŶůĞƚ͕ƵŶĚĞƌŚŝŐŚͲĨůŽǁĐŽŶĚŝƚŝŽŶƐŝƚĐĂŶƌĞƐƵůƚŝŶĂŶĂĚĚŝƚŝŽŶĂůϭ͟ͲϮ͟ǁ͘Đ͘ŽĨƉƌĞƐƐƵƌĞĚŝĨĨĞƌĞŶĐĞƚŚĂƚ ĐĂŶŶŽƚďĞĞůŝŵŝŶĂƚĞĚ͘ŚƚƚƉƐ͗ͬͬĞŶ͘ǁŝŬŝƉĞĚŝĂ͘ŽƌŐͬǁŝŬŝͬĞƌŶŽƵůůŝйϮϳƐͺƉƌŝŶĐŝƉůĞ ϳWŽǁĞƌĞƐŝŐŶWƌŽŝƐ'ĞŶĞƌĂĐ͛ƐǁĞďͲďĂƐĞĚŐĞŶĞƌĂƚŽƌƐŝnjŝŶŐƚŽŽůƚŚĂƚŝŶĐůƵĚĞƐŵŽĚƵůĞƐĨŽƌŐĂƐƐƵƉƉůLJƉŝƉĞƐŝnjŝŶŐ ĂŶĚĞdžŚĂƵƐƚƉŝƉĞƐŝnjŝŶŐ͘/ƚĐĂŶďĞĂĐĐĞƐƐĞĚĂŶĚƵƐĞĚĨƌĞĞŽĨĐŚĂƌŐĞĂƚ͗ŚƚƚƉƐ͗ͬͬƉĚƉ͘ƉŽǁĞƌĚĞƐŝŐŶƉƌŽ͘ĐŽŵ͘ ϴ>WͲ'ĂƐ^ĞƌǀŝĐĞŵĂŶ͛Ɛ,ĂŶĚŬ͕ŵĞƌƐŽŶ&ŝƐŚĞƌ͘ ŚƚƚƉ͗ͬͬǁǁǁ͘ƐƋƵŝďďƚĂLJůŽƌ͘ĐŽŵͬƵƉůŽĂĚĞĚͬůƉϭϬƐĞƌǀŝĐĞŵĂŶŝŶƐƚ͘ƉĚĨ 4 Generac Power Systems, Inc. P. O. B o x 8 Waukesha , WI 53189 888-GENERAC © 2018 Generac Power Systems, Inc. All rights reserved. Document No. 10000046207 LEGEND CT1CT2CT3MLCBMLCBNBNBCOMPONENTS LOCATED IN ALTERNATOR CONNECTION BOXIFTEXCCOMPONENTS LOCATED IN HIGH VOLTAGE CUSTOMER CONNECTION MODULECONNECTIONSFOR 1Ø UNITCONNECTIONSFOR 3Ø UNITIFT34COMPONENTS LOCATED IN HIGH VOLTAGE CUSTOMER CONNECTION MODULEGFCIRECEPTACLEUS & CANADA ONLYUS & CANADA ONLY240VUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYGFCILOAD CENTERUS & CANADA ONLY125ATB4GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 1 OF 12PAGE 2 OF 12 COMPONENTS LOCATED IN HIGH VOLTAGE CUSTOMER CONNECTION MODULETB5RUN RELAYRB3ARB3TB1TB2COMPONENTS LOCATED ON LOW VOLTAGE CUSTOMER CONNECTION PANEL**FOR DUAL FUEL UNITS ONLYGROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 3 OF 12PAGE 4 OF 12 F4F3F2F1COCOSWCTB3SWCSWCSWCSW1COSWCES1AH1AVRCBRB1RB1ACOMPONENTS LOCATED IN CONTROL PANELR1DBCOMMODCO3BCHBCCFSPALTSM1SC2GNDCOMPONENTS LOCATED ON ENGINECOMPONENTS LOCATED IN CONTROL PANELCOCOCORB2RB2AGROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 5 OF 12PAGE 6 OF 12 LP LIQUIDCOMPONENTS LOCATED ON ENGINEBOTH NATURAL GAS & LP VAPORLFPFSRAFSFS3FS1FS2FSRFS1FSAUXAFSLFPFSRFS3FS1FS2NATURAL GASAFSFS1FSAUXLP LIQUIDFOR DUAL FUEL NG/LPL UNITS ONLYCOMPONENTS LOCATED ON ENGINEGROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 7 OF 12PAGE 8 OF 12 COMPONENTS LOCATED ON ENGINEFOR DUAL FUEL NG/LPV UNITS ONLYLFPFSRFS3LP VAPORFS1FS2FS1FS2NATURAL GASAFSCOMPONENTS LOCATED ON ENGINEDISTGAGA1GDINSMPU1ATS1OPS1WTS1OSWLS1OTS1OTSATSWTSWLSOTCGROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 9 OF 12PAGE 10 OF 12 J1J2ENGINE CONTROL MODULE CONNECTORSPAGE LEFT INTENTIONALLY BLANKGROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14GROUP GWIRING - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9429REVISION: K-1105-BDATE: 10/24/14PAGE 11 OF 12PAGE 12 OF 12 CT1CT2CT3CT2CT1IFTIFTOTS1GA1WLS1 WTS1OPS1GAGDOTSWTSWLSMPU1AFSATSATS1OSMLCBRB3STBCHUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYUS & CANADA ONLYFOR DUAL FUEL UNITS ONLYGROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14GROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14PAGE 1 OF 6PAGE 2 OF 6 FS1LFPSMALTSCBATFS2FS3FS1FSAUXFS2FS1LFPFS3FOR DUAL FUEL NG/LPL UNITS ONLYFOR NG & LPVUNITS ONLYFS1FSAUXFOR LPLUNITS ONLYFS1FS2FS1LFPFS3FOR DUAL FUEL NG/LPV UNITS ONLYFS2RB1COMBCHES1FAH1SW1AVRDBR1CBDISTINSRB2GROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14GROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14PAGE 3 OF 6PAGE 4 OF 6 AVR CONNECTORJ1ENGINE CONTROL MODULE CONNECTIONSJ2GD CONNECTORPAGE LEFT INTENTIONALLY BLANKGROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14GROUP GSCHEMATIC - DIAGRAMG9.0L G18 TURBO H-PANELDRAWING #: 0K9430REVISION: J-1105-BDATE: 10/24/14PAGE 6 OF 6PAGE 5 OF 6 GENERATOR CONTROLS1 OF 1 Part No. 0191120SSDRev. &//1Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187P: (262) 544-4811 © 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. CONTROL INTERCONNECTIONS H-PANEL, CCI GTS TRANSFER SWITCH RB3 HTS TRANSFER SWITCH RAP/RRP LOW VOLTAGE CONNECTION PANEL SPARE OUTPUTS NOTE 1 + 3 NOTE 4 NOTE 5 NOTES: SPARE OUTPUTS ARE STANDARD ON INDUSTRIAL PRODUCT ONLY. GENLINK™ REQUIRED FOR PROGRAMMING. CONTACTS RATED $$7 9$&9'&. TB4 MAX WIRE SIZE: #10 AWG, RECOMMENDED TIGHTENING TORQUE: 14 LB-IN TB1, TB2 & RB3 MAX WIRE SIZE: #14 AWG RECOMMENDED TIGHTENING TORQUE: 12 LB-IN REFER TO H-PANEL MANUAL FOR INSTRUCTIONS ON ENABLING HTS TRANSFER SWITCH. REFER TO HTS TRANSFER SWITCH MANUAL FOR DIP SWITCH SETTINGS FOR MULTIPLE HTS APPLICATIONS. CONNECT THE RS485 OVERALL SHIELD AT GENSET CONNECTION TERMINAL ONLY. NOTE 5 125ALOAD CENTER TB1 TB2 HIGH VOLTAGE CONNECTION PANEL NOTE 2 NOTE 3 NOTE 3 TB4 120/240 VACUTILITY SUPPLY (BY CUSTOMER) VERIFY COMPONENTRATINGS FOR PROPER SUPPLY VOLTAGE TO BE PROVIDED. Part No. 0184520SSDRev. B 03/01/12Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187P: (262) 544-4811 © 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Certification of Quality Generac Power Systems certifies that the products we manufacture have been built and tested in accordance with strict internal and external standards for quality. Our quality management system has been registered with the internationally recognized ISO 9001:2008 standard and our products comply with external standards that include, but are not limited to, CSA, NEMA, EGSA, ISO, and UL. The Generac Quality Management System (GQMS) ensures the highest standards of quality at every level of production, from raw materials to the finished product. This includes receiving inspection, in-process checks, product and process audits, testing, final inspections, and shipping standards. Tests of our products are performed in accordance with our internal procedures and controlled through the GQMS to ensure accuracy and effectiveness. The testing process and product designs comply with external standards which may include, but are not limited to: ISO 8528-5, ISO 3046, NFPA 99, NFPA 110, BS 5514, SAE J1349, and DIN 6271. Generac Power Systems has over one million square feet of manufacturing space and over 2000 employees dedicated to designing and manufacturing power generation equipment in our multiple State of Wisconsin, USA factories. All of our installed and mobile generators are built with pride by our skilled American workforce to ensure our customers receive the quality that they expect from Generac. We are committed to producing quality products for both our internal and external customers. We will continuously improve our processes and diligently measure all aspects of our business. Vice President of Quality Generac Power Systems, Inc. Waukesha, Wisconsin USA Daniel Waschow Generac Power Systems 2 Year (2B) Limited Warranty for Industrial Standby Generators For the period of warranty noted below, which begins upon the successful start-up and/or on-line activation of the unit, Generac Power Systems,Inc. “Generac” warrants that its Generator will be free from defects in material and workmanship for the items and period set forth below. Generacwill, at its discretion, repair or replace any part(s) which, upon evaluation, inspection and testing by Generac or an Independent Authorized ServiceDealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be evaluated by the nearest IndependentAuthorized Service Dealer. Emissions components are excluded from coverage under this extended warranty. Emissions warranty coverage isdetailed in a separate emissions warranty. Warranty Coverage: Warranty coverage period is for Two (2) years or two-thousand (2,000) hours, whichever occurs first. Limited Gearbox Coverage: Guidelines: The following will NOT be covered by this warranty: THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHERWARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTIES WHICH ARE ALLOWEDBY LAW, SHALL BE LIMITED IN DURATION TO THE TERMS OF THE EXPRESS WARRANTY PROVIDED HEREIN. SOME JURISDICTIONS DO NOTALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. GENERAC'S ONLYLIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANYINCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. SOMEJURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVELIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU ALSO HAVE OTHER RIGHTS UNDERAPPLICABLE LAW. FOR AUSTRALIA ONLY: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to areplacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have thegoods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.FOR NEW ZEALAND ONLY: Nothing in this warranty statement excludes, restricts or modifies any condition, warranty right or remedy whichpursuant to the New Zealand Legislation (Commonwealth or State) including the Fair Trading Practices Act of 1986 or the Consumer Guarantees Act1993 (“CGA”) applies to this limited warranty and may not be so excluded, restricted or modified. Nothing in this statement is intended to have theeffect of contracting out of the provisions of the CGA, except to the extent permitted by that Act, and these terms are to be modified to the extentnecessary to give effect to that intention. If you acquire goods from Generac Power Systems or any of its authorized resellers and distributors for thepurposes of a business, then pursuant to section 43(2) of the CGA, it is agreed that the provisions of the CGA do not apply. GENERAC POWER SYSTEMS, INC. • P.O. BOX 8 • Waukesha, WI, USA 53187Ph: (888) GENERAC (436-3722) • Fax: (262) 544-4851 To locate the nearest Independent Authorized Service Dealer and to download schematics, exploded views and parts lists visit our website: www.generac.com Part No. 0K3486 Revision E (2/16) Warranty Coverage in Year(s): 1 Warranty Coverage in Year(s): 2 Parts, Labor and Limited Travel Limited Parts Only Year(s): 1-5 Coverage Year(s): 6-10 Coverage Limited Parts and Labor Limited Parts Only 1.Unit must be registered and proof of purchase available.2.Any and all warranty repairs and/or concerns must be performed and/or addressed by an Independent Authorized ServiceDealer, or branch thereof. Repairs or diagnostics performed by individuals other than Independent Authorized Service Dealersnot authorized in writing by Generac will not be covered.3.This Warranty is transferable between ownership of original install site.4.Generac supplied engine coolant heaters (block-heaters),heater controls and circulating pumps are only covered during the first year of the warranty provision.5.Generac may choose to repair, replace or refund a piece of equipment in its sole discretion.6.Enclosures are warranted against rust for the first year of ownership only. Damage caused after receipt of generator is the responsibility of the owner and is not covered by this warranty. Nicks, scrapes, dents or scratches to the painted enclosure should be repaired promptly by the owner. 7.Warranty only applies to permanently wired and mounted units.8.Damage to any covered components or consequential damages caused by the use of a non-OEM part will not be covered by the warranty.9.Proof of performance of all required maintenance must beavailable.10.Travel allowance is limited to 300 miles maximum and seven and one half (7.5) hours maximum (per occurrence, whichever is less) round trip from the nearest Independent Authorized Service Dealer. Any additional travel required will not becovered.11.Engines, driven components and fuel tanks used in Generac’sstandby power products system can carry a separate manufacturer’s (OEM) warranty (the “OEM Warranties”), unless otherwise expressly stated. OEM Warranties are in addition to this Warranty. All warranty claims for defects in material and/or workmanship on Generac product OEM components, may be directed through the OEM distributor/dealer network. OEM Warranties may vary and are subject to change. Generac shall have no liability under OEM warranties. 1.Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up).2.Damage/failures to the generator and/or transfer switch system caused by accidents, shipping, handling, or improper storage.3.Damage/failures caused by operation with improper fuels, speeds, loads or installations other than what’s recommended or specified by Generac Power Systems.4.Damage to the generator and/or transfer switch due to the use of non-Generac parts and/or equipment, contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oil or coolants/antifreeze.5.Failures due to normal wear and tear, accident, misuse, abuse, neglect, improper installation, improper sizing, or rodent, reptile, and/or insect infestation.6.Rental equipment used while warranty repairs are being performed and/or any extraordinary equipment used for removal and/or reinstallation of generator (i.e. cranes, hoists, lifts, et. al.).7.Planes, ferries, railroad, buses, helicopters, snowmobiles, snow-cats, off-road vehicles or any other mode of transport deemed not standard by Generac. 8.Products that are modified or altered in a manner not authorizedby Generac in writing.9.Starting batteries, fuses, light bulbs, engine fluids and anyrelated labor.10.Steel enclosures that rust as a result of improper installation, location in a harsh or salt water environment, or are scratched where the integrity of applied paint is compromised.11.Units sold, rated or used for "Prime Power", "Trailer Mounted" or"Rental Unit" applications as defined by Generac. Contact an Independent Authorized Service Dealer for definitions.12.Shipping costs associated with expedited shipping.13.Additional costs for overtime, holiday or emergency labor costs for repairs outside of normal business hours. 14.Any incidental, consequential or indirect damages caused bydefects in materials or workmanship, or any delay in repair or replacement of the defective part(s).15.Failures caused by any act of God or external cause including without limitation, fire, theft, freezing, war, lightning, earthquake, windstorm, hail, water, tornado, hurricane, or any other matters which are reasonably beyond the manufacturer’s control. Garantía limitada de 2 años (2B) de Generac Power Systems para los generadores de respaldo industriales Durante el período de garantía indicado abajo, que comienza desde la puesta en marcha y/o activación exitosa en línea de la unidad, Generac PowerSystems, Inc. “Generac” garantiza que generador estará libre de defectos de material y/o mano de obra para los ítems y el período indicados a continuación.Generac, a su discreción, reparará o sustituirá cualquier pieza o piezas que, por medio de la evaluación, inspección y prueba efectuada por Generac o unConcesionario de servicio autorizado independiente de Generac, se determine que es o son defectuosa(s). Todo equipo que el comprador o propietarioreclame como defectuoso debe ser evaluado por el Concesionario de servicio autorizado independiente de Generac más cercano. Los componentesrelacionados con emisiones están excluidos de la cobertura bajo esta garantía extendida. La cobertura de la garantía de emisiones se detalla por separadoen una garantía de emisiones.Cobertura de la garantía: El período de cobertura de la garantía es de dos (2) años o dos mil (2000) horas, lo que ocurra primero. Cobertura limitada sobre la caja de engranajes: Directrices: Lo siguiente NO será cubierto por esta garantía: ESTA GARANTÍA SUSTITUYE CUALQUIER OTRA GARANTÍA, EXPRESA O IMPLÍCITA. ESPECÍFICAMENTE, GENERAC NO EXTIENDE NINGUNA OTRAGARANTÍA ACERCA DE LA COMERCIALIZACIÓN O APTITUD PARA UN PROPÓSITO EN PARTICULAR. LA DURACIÓN DE TODAS LAS GARANTÍASIMPLÍCITAS PERMITIDAS POR LA LEY ESTARÁ LIMITADA A LAS CONDICIONES DE LA GARANTÍA EXPRESA ESTIPULADA EN LA PRESENTE. ALGUNASJURISDICCIONES NO PERMITEN LIMITACIONES DE LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA; POR LO TANTO, LA LIMITACIÓN PRECEDENTE PUEDENO APLICARSE A USTED. LA ÚNICA RESPONSABILIDAD DE GENERAC SERÁ REPARAR O SUSTITUIR LA(S) PIEZA(S) COMO SE ESTIPULÓPRECEDENTEMENTE. GENERAC NO SERÁ RESPONSABLE EN NINGÚN CASO POR NINGÚN DAÑO ACCESORIO O EMERGENTE, AUN CUANDO TAL DAÑOSEA RESULTADO DIRECTO DE LA NEGLIGENCIA DE GENERAC. ALGUNAS JURISDICCIONES NO PERMITEN LA EXCLUSIÓN O LIMITACIÓN DE DAÑOSACCESORIOS O EMERGENTES, DE MANERA QUE LA LIMITACIÓN PRECEDENTE PUEDE NO APLICARSE A USTED. ESTA GARANTÍA LE OTORGADERECHOS LEGALES ESPECÍFICOS. TAMBIÉN TIENE OTROS DERECHOS BAJO LA LEY CORRESPONDIENTE. SOLO PARA AUSTRALIA: Nuestros productos se entregan con garantías que no pueden ser excluidas según la Australian Consumer Law (Ley australiana deconsumidores). Usted tiene derecho a sustitución o reembolso por un fallo mayor y a compensación por cualquier otra pérdida o daño razonable previsible.Usted también tiene derecho a que los bienes sean reparados o sustituidos si los bienes no son de calidad aceptable y la falla no llega a ser un fallo mayor.SOLO PARA NUEVA ZELANDA: Nada de esta declaración de garantía excluye, restringe o modifica ninguna condición, derecho de garantía o solución que,conforme a la legislación de Nueva Zelanda (Comunidad o Estado), incluso la Fair Trading Practices Act (Ley de transacciones comerciales justas) de 1986 o laConsumer Guarantees Act (Ley de garantías de los consumidores, “CGA”) de 1993, se aplique a esta garantía limitada y por lo tanto no puede ser sometida aexclusiones, restricciones o modificaciones. Nada de esta declaración tiene el propósito de tener efecto de contratar fuera de las previsiones de la CGA, exceptocon el alcance permitido por la ley y estos términos se deben modificar con el alcance necesario para hacer efectiva esta intención. Si adquiere bienes deGenerac Power Systems o alguno de sus revendedores y distribuidores autorizados con propósitos comerciales, entonces, conforme a la sección 43(2) de laCGA, se acuerda que no se aplican las previsiones de la CGA. GENERAC POWER SYSTEMS, INC. • P.O. BOX 8 • Waukesha, WI 53187, EE. UU.Tel.: (888) GENERAC (436-3722) • Fax: (262) 544-4851 Para ubicar el Concesionario de servicio autorizado independiente más cercano y descargar diagramas esquemáticos, despieces y listas de piezas visite nuestro sitio Web: www.generac.com Núm. de pieza 0K3486 Revisión E (0/16) Cobertura de la garantía en el o los año(s): 1 Cobertura de la garantía en el o los año(s): 2 Sobre piezas, mano de obra y gastos de viaje limitados Limitada solo sobre piezas Año(s) de cobertura: 1-5 Cobertura Año(s) de cobertura: 6-10 Cobertura Limitada sobre piezas y mano de obra Limitada solo sobre piezas 1.La unidad debe estar registrada y tener prueba de compra disponible.2.Cualquiera y todas las reparaciones y/o preocupaciones por garantía deben ser efectuadas y/o dirigidas por un Concesionario de servicio autorizado independiente de Generac, o una sucursal de este. No serán cubiertas las reparaciones o los diagnósticos efectuados por personas diferentes de los Concesionarios de servicio autorizados independientes de Generac no autorizados por escrito por Generac.3.Esta garantía es transferible entre propietarios del sitio de instalación original.4.Los calentadores de refrigerante de motor (calentadores de bloque), los controles del calentador y las bombas de circulación suministrados por Generac solo están cubiertos durante el primer año de prestación de la garantía.5.Generac puede elegir reparar, sustituir o reembolsar una pieza del equipo a su exclusiva discreción. 6.Los gabinetes están garantizados contra corrosión solamente durante el primer año de propiedad. El daño causado después de la recepción del generador es responsabilidad del comprador y no está cubierto por esta garantía. Las muescas, raspaduras, abolladuras o rayaduras de gabinete pintado deben ser reparadas sin demora por el propietario. 7.La garantía corresponde solamente a las unidades conectadas y montadas en forma permanente.8.Los daños a cualquier componente o los daños emergentes causados por el uso de una pieza que no sea OEM no estarán cubiertos por la garantía.9.Debe haber disponible prueba de la ejecución de todo el mantenimiento requerido.10.Las asignaciones para viaje están limitadas a 300 millas como máximo y siete horas y media (7.5) horas como máximo (por ocurrencia, lo que sea menor), viaje de ida y vuelta, desde el Concesionario de servicio autorizado independiente de Generac más cercano. Todo gasto de viaje adicional requerido no será cubierto.11.Los motores, los componentes accionados y los tanques de combustible usados en los productos de respaldo de Generac pueden llevar una garantía de fabricante (OEM) separada (las “Garantías de OEM”), a menos que se estipule expresamente lo contrario. Las garantías de OEM son un agregado a esta garantía. Todos los reclamos de garantía por defectos de material y/o mano de obra en los componentes OEM del producto Generac, pueden ser dirigidos a través de la red de distribuidores/concesionarios OEM. Las garantías de OEM pueden variar y están sujetas a cambios. Generac no tendrá responsabilidad bajo las garantías de OEM. 1.Costes del mantenimiento normal (es decir: afinaciones, pieza[s] relacionada[s], ajustes, abrazaderas sueltas o con fugas, instalación y puesta en marcha).2.Daños/fallos del sistema de generador y/o interruptor de transferencia causados por accidentes, envío, manipulación, o almacenamiento incorrecto.3.Los daños/fallos causados por la operación con combustibles, velocidades, cargas, o instalaciones incorrectas diferentes de las recomendadas o especificadas por Generac Power Systems.4.Los daños al generador y/o el interruptor de transferencia debidos aluso de piezas y/o equipos que no sean de Generac; combustibles, aceites, refrigerantes/anticongelantes contaminados; o falta de combustibles, aceites, refrigerantes/anticongelantes apropiados.5.Fallos debidos a: desgaste y daño normal, accidente, uso indebido, abuso, negligencia, instalación incorrecta, dimensionamiento incorrecto, o plagas de roedores y/o insectos.6.Equipos arrendados usados mientras se llevan a cabo reparaciones de garantía y/o todos los equipos extraordinarios usados para retirar y/o reinstalar el generador, (esto es: grúas, malacates, elevadores, etc.).7.Aeronaves, transbordadores, ferrocarril, autobuses, helicópteros, motocicletas para nieve, camiones para nieve, vehículos fuera de ruta o cualquier otro modo de transporte no considerado estándar por Generac. 8.Productos que se modifiquen o alteren en forma no autorizada por Generac por escrito.9.Baterías de arranque, fusibles, bombillas de luz, fluidos para el motor y mano de obra relacionada.10.Los gabinetes de acero que se corroen debido a instalación incorrecta, ubicación en un entorno agresivo o con agua salada, o se rayen donde esté comprometida la integridad de la pintura aplicada.11.Las unidades vendidas, calificadas para, o usadas en aplicaciones de “Alimentación eléctrica principal”, “Montada en remolque” o “Unidad en alquiler” como las define Generac. Comuníquese con un Concesionario de servicio autorizado independiente para las definiciones.12.Costes de envío asociados con envío urgente.13.Costes adicionales por horas extra y feriados o los costes de mano de obra de emergencia por reparaciones fuera del horario de trabajo normal. 14.Todos los daños accesorios, emergentes o indirectos causados por defectos en los materiales o mano de obra o toda demora en la reparación o sustitución de la(s) pieza(s) defectuosa(s).15.Los fallos causados por cualquier acto de fuerza mayor o causa externa, que incluyen, sin limitaciones, incendio, robo, congelamiento, guerra, rayos, terremoto, tormenta de viento, granizo, agua, tornado, huracán, o cualesquiera otros asuntos que estén fuera del control razonable del fabricante. Garantie limitée de 2 ans (2B) de Generac Power Systems sur les générateurs de secours industriels Pendant la période de garantie mentionnée ci-bas, qui débute dès le démarrage réussi de l’appareil ou l’activation en ligne de l’appareil,Generac Power Systems, Inc. (Generac) garantit que son générateur sera exempt de vices de matériaux et fabrication en ce qui concerne les éléments et lapériode indiqués ci-dessous. À sa seule discrétion, Generac réparera ou remplacera toute pièce qui est jugée défectueuse après l’évaluation, l’inspection etla mise à l’essai par Generac ou un fournisseur de services d’entretien agréé indépendant. Tout équipement que l’acheteur/propriétaire prétend êtredéfectueux doit être évalué par le fournisseur de services d’entretien agréé indépendant le plus près. Les composantes relatives aux émissions ne sont pascouvertesen vertu de la présente garantie. La couverture des composantes relatives aux émissions est détaillée dans une garantie distincte. Couverture de la garantie : La période de garantie est de deux (2) ans ou de deux mille (2000) heures, selon la première éventualité. Couverture limitée de la boîte à engrenages : Lignes directrices : Les éléments suivants ne seront PAS couverts par la présente garantie : LA PRÉSENTE GARANTIE REMPLACE TOUTES LES AUTRES GARANTIES, EXPLICITES OU IMPLICITES. EN PARTICULIER, GENERAC N’OFFRE AUCUNEAUTRE GARANTIE QUANT À LA QUALITÉ MARCHANDE OU À LA CONVENANCE À UN USAGE PARTICULIER. TOUTE GARANTIE IMPLICITE AUTORISÉEPAR LA LOI SERA LIMITÉE À LA DURÉE DE LA PÉRIODE DE LA PRÉSENTE GARANTIE EXPLICITE. CERTAINS ÉTATS OU PROVINCES NE PERMETTENTPAS LES LIMITATIONS SUR LA DURÉE D’UNE GARANTIE IMPLICITE ET, PAR CONSÉQUENT, LA PRÉSENTE LIMITATION PEUT NE PAS S’APPLIQUER. LARESPONSABILITÉ DE GENERAC SE LIMITERA À LA RÉPARATION OU AU REMPLACEMENT DES PIÈCES, COMME INDIQUÉ PRÉCÉDEMMENT. EN AUCUNCAS GENERAC NE POURRA ÊTRE TENUE RESPONSABLE DE DOMMAGES ACCESSOIRES OU SUBSÉQUENTS, MÊME SI LES DOMMAGES RÉSULTENTDIRECTEMENT DE LA NÉGLIGENCE DE GENERAC. CERTAINS ÉTATS OU PROVINCES N’AUTORISENT PAS L’EXCLUSION NI LA LIMITATION DESDOMMAGES ACCESSOIRES OU INDIRECTS ET, PAR CONSÉQUENT, LA LIMITATION ÉNONCÉE CI-DESSUS PEUT NE PAS S’APPLIQUER. CETTE GARANTIEVOUS CONFÈRE DES DROITS LÉGAUX PRÉCIS. VOUS POUVEZ ÉGALEMENT JOUIR D’AUTRES DROITS EN VERTU DES LOIS APPLICABLES. POUR L’AUSTRALIE UNIQUEMENT : Nos produits sont fournis avec des garanties qui ne peuvent être exclues en vertu de la loi australienne sur laconsommation (Australian Consumer Law). Vous avez droit à un remplacement ou à un remboursement pour une défaillance majeure et à une indemnisationpour toute autre perte ou tout dommage raisonnablement prévisible. Vous disposez également d’un droit à la réparation ou au remplacement si les produits nesont pas d’une qualité acceptable et si cette défaillance n’est pas considérée comme majeure.POUR LA NOUVELLE-ZÉLANDE UNIQUEMENT : Cette garantie n’exclut, ne restreint ni ne modifie aucune condition, aucun droit de garantie ou recours qui,conformément à la législation de Nouvelle-Zélande (Commonwealth ou État), y compris la loi sur la pratique commerciale loyale de 1986 (Fair Trading Practices Act) oula loi sur la protection du consommateur de 1993 (CGA ou Consumer Guarantees Act), s’applique à cette garantie limitée et ne peut pas être exclue, restreinte oumodifiée. Cette garantie ne vise en aucun cas à contourner les dispositions de la CGA, sauf dans la mesure permise par cette loi, et ces termes doivent être modifiésdans la mesure nécessaire pour donner effet à cette intention. Si vous faites l’acquisition d’un produit de Generac Power Systems ou d’un de ses distributeurs etrevendeurs autorisés à des fins commerciales, alors, conformément à l’article 43(2) de la CGA, il est convenu que les dispositions de la CGA ne s’appliquent pas. GENERAC POWER SYSTEMS, INC. • C.P. 8 • Waukesha, WI (É.-U.) 53187 Téléphone : (888) GENERAC (436-3722) • Télécopieur : (262) 544-4851 Pour trouver le fournisseur de services d’entretien agréé indépendant le plus près et pour télécharger les schémas, les vues éclatées et les listes de piècesvisitez notre site Web : www.generac.com Pièce no 0K3486 Révision E (/16) Période de garantie : 1 Période de garantie : 2 Pièces, main-d’œuvre et couverture limitée des déplacements Couverture limitée – pièces seulement Période : couverture de 1 à 5 ans Période : couverture de 6 à 10 ans Couverture limitée – pièces et main-d’œuvre Couverture limitée – pièces seulement 1.L’appareil doit être enregistré et la preuve d’achat doit être présentée sur demande.2.Toute réparation sous garantie doit être effectuée par un fournisseur de services d’entretien agréé indépendant ou l’une de ses succursales, et toute préoccupation doit être également traitée par un fournisseur de services d’entretien agréé indépendant de Generac ou l’une de ses succursales. Toute réparation ou évaluation effectuée par des personnes autres que des fournisseurs de services d’entretien agréés indépendants qui n’a pas été autorisée par écrit par Generac ne sera pas couverte.3.La présente garantie est transférable conjointement à la propriété du site d’installation d’origine.4.Les chaufferettes à liquide de refroidissement du moteur (chauffe-moteur), les commandes de chauffage et les pompes de circulationfournies par Generac ne sont couvertes que pendant la première année de la période de garantie.5.Generac peut choisir, à sa seule discrétion, de réparer, de remplacer ou de rembourser une pièce d’équipement. 6.Les boîtiers sont garantis contre la rouille pendant la première année de possession seulement. Les dommages causés après la réception du générateur sont la responsabilité du propriétaire et ne sont pas couverts par la présente garantie. Les entailles, éraflures, bosses ou égratignures au boîtier peint doivent être réparées sans délai par le propriétaire. 7.La garantie s’applique uniquement aux appareils montés et câblés en permanence.8.Aucun dommage ou dommage indirect à toute pièce couverte découlant de l’utilisation de pièces non fabriquées par un fabricant d’équipement d’origine ne sera couvert par la garantie.9.Une preuve d’exécution de tous les travaux d’entretien requis doit être présentée sur demande.10.La présente garantie couvre les déplacements aller-retour d’un maximum de 480 km (300 miles) et de sept heures et demie (7,5) (par déplacement, selon le moindre des deux) à partir du fournisseur de services d’entretien agréé indépendant le plus près. Tout déplacement supplémentaire requis ne sera pas couvert.11.Les moteurs, les pièces d’entraînement et les réservoirs de carburant utilisés dans les systèmes d’alimentation de secours de Generac peuvent être protégés au titre de la garantie d’un fabricant d’équipement distinct (les « garanties des fabricants d’équipement d’origine »), sauf indication expresse à l’effet contraire. Les garanties des fabricants d’équipement d’origine s’ajoutent à la présente garantie. Toute réclamation au titre de la garantie pour vices de matériaux ou de fabrication de pièces d’un fabricant d’équipement d’origine sur un produit Generac peut être faite auprès du distributeur ou du réseau de fournisseurs de ce fabricant d’équipement d’origine. Les garanties des fabricants d’équipement d’origine peuvent varier et faire l’objet de modifications. Generac n’a aucune responsabilité découlant des garanties offertes par les fabricants d’équipement d’origine. 1.Les coûts d’entretien normal (c’est-à-dire mises au point, réglages de pièces associées, ajustements, resserrage de fixations, installation et démarrage).2.Les dommages ou défaillances du générateur et/ou du commutateur de transfert causés par un accident, le transport, la manutention ou un entreposage inadéquat.3.Les dommages/défaillances causés par l’utilisation de carburants inappropriés ou l’utilisation à des vitesses, avec des charges ou selon une installation autres que ce qui est recommandé ou spécifié par Generac Power Systems.4.Les dommages au générateur et/ou au commutateur de transfert causés par l’utilisation de pièces ou d’équipement non fabriqués par Generac, de carburant, d’huile, de liquide de refroidissement et d’antigel contaminé ou encore du manque de carburant, d’huile, de liquide de refroidissement et d’antigel.5.Les défaillances causées par l’usure normale, un accident, une utilisation inappropriée, une utilisation abusive, une négligence, une installation inadéquate, un dimensionnement inadéquat ou une infestation de rongeurs, de reptiles ou d’insectes.6.L’équipement de location utilisé pendant que des réparations sous garantie sont effectuées et/ou tout équipement extraordinaire utilisé pour retirer ou réinstaller le générateur (c’est-à-dire grues, appareils de levage, élévateurs, etc.).7.Les avions, les traversiers, les trains, les autobus, les hélicoptères, les motoneiges, les dameuses, les véhicules hors route ou tout autre moyen de transport jugé non standard par Generac. 8.Les produits modifiés ou altérés d’une manière qui n’a pas été autorisée par écrit par Generac.9.Les batteries de démarrage, les fusibles, les ampoules électriques, les fluides de moteur et toute main-d’œuvre connexe.10.Les boîtiers en acier qui rouillent en raison d’une installation inadéquate, d’une installation dans un environnement difficile ou salin ou d’égratignures qui compromettent l’intégrité de la peinture appliquée sur le boîtier.11.Les appareils vendus, cotés ou utilisés selon les applications suivantes, telles qu’elles sont définies par Generac : « puissance électrique de base », « monté sur remorque » ou « unité de location ». Veuillez communiquer avec un fournisseur de services d’entretien agréé indépendant pour obtenir les définitions.12.Les coûts d’expédition liés à l’expédition accélérée.13.Les coûts supplémentaires liés aux heures supplémentaires, aux jours fériés ou aux services d’urgence pour toute réparation effectuée en dehors des heures normales de bureau. 14.Tout dommage accessoire, subséquent ou indirect causé par un défaut de matériau et de fabrication ou par tout retard dans la réparation ou le remplacement de pièces défectueuses.15.Les défaillances causées par un cas de force majeure ou une cause externe y compris, sans toutefois s’y limiter, le feu, le vol, le gel, la guerre, la foudre, un tremblement de terre, une tempête, la grêle, la pluie, une tornade, un ouragan ou toute autre situation raisonnablement hors du contrôle du fabricant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nited States Environmental Protection Agency Warranty Statement (Stationary Emergency Spark-Ignited Generators) Warranty Rights, Obligations and Coverage The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain the Emission Control System Warranty on your new stationary emergency engine. If during the warranty period, any emission control system or compo- nent on your engine is found defective in materials or workmanship, Generac will repair your engine at no cost to you for diagnosis, replace- ment parts and labor provided it be done by a Generac Authorized Warranty Service Facility. Your emission control system may include parts such as the fuel metering, ignition, and exhaust systems and other related emission related components listed below. Generac will warrant the emissions control systems on your 2009 and later model year engines provided there has been no abuse, neglect, unapproved modifica- tion, or improper maintenance of your engine. For engines less than 130 HP the warranty period is two years from the date of sale to the ulti- mate purchaser. For engines greater than or equal to 130 HP the warranty period is three years or 2500 hours of operation, whichever comes first, from the date of the engine being placed into service. For high-cost warranted components, the Emission Control System war- ranty is valid for 5 years or 3500 hours of operation, whichever comes first. Purchaser's/Owner's Warranty Responsibilities As the engine purchaser/owner you are responsible for the following: 1) The engine must be installed and configured in accordance to Gen- erac's installation specifications. 2) The completion of all maintenance requirements listed in your Owner's Manual. 3) Any engine setting adjustment must be done in accordance and consistent with the instructions in the Owner's Manual. 4) Any emission control system or com- ponent must be maintained and operated appropriately in order to ensure proper operation of the engine and control system to minimize emissions at all times. Generac may deny any/or all Emission Control System Warranty coverage or responsibility of the engine, or an emission control system or component on your engine thereof, if it has failed due to abuse, neglect, unapproved modification or improper maintenance, or the use of counterfeit and/or “gray market” parts not made, supplied or approved by Generac. Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service dealer, 1-800-333-1322 for the dealer nearest you. The purchaser/owner shall be responsible for any expenses or other charges incurred for service calls and/or transportation of the product to/from the inspection or repair facilities. The purchaser/owner shall be responsible for any and/or all damages or losses incurred while the engine is being trans- ported/shipped for inspection or warranty repairs. Contact Generac Power Systems Inc. for additional Emission Control System Warranty related information, Generac Power Systems, Inc., PO. Box 8, Waukesha, WI 53187, or call 1-800-333-1322 or www.generac.com. Important Note This warranty statement explains your rights and obligations under the Emission Control System Warranty, which is provided to you by Gen- erac pursuant to federal law. Note that this warranty shall not apply to any incidental, consequential, or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part(s). This warranty is in place of all other warranties, expressed or implied. Specifically, Generac makes no other warranties as to the merchantability or fitness for a particular purpose. Any implied warranties which are allowed by law, shall be limited in duration to the terms of the express warranty provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Emission Related Parts Include the Following (if so equipped) *High-Cost Warranted Component EmsnWrnty001 Revision F (04/15) 1) Fuel Metering System 1.1) Gasoline Carburetor Assembly and Internal Components A) Fuel Filter, B) Carburetor, C) Fuel Pump 1.2) Carburetion Assembly and Its Components A) Fuel Controller, B) Carburetor and Its Gaskets, C) Mixer and Its Gaskets, D) Primary Gas Regulator, E) Liquid Vaporizer 1.3) Fuel Regulator 2) Air Induction System Including A) Intake Pipe/Manifold, B) Air Cleaner 3) Ignition System Including A) Spark Plug, B) Ignition Module, C) Ignition Coil, D) Spark Plug Wires 4) Exhaust System A) Catalyst Assembly*, B) Exhaust Manifold, C) Muffler, D) Exhaust Pipe, E) Muffler Gasket 5) Crankcase Breather Assembly Including A) Breather Connection Tube, B) PCV Valve 6) Oxygen Sensor 7) Diagnostic Emission-Control System United States Environmental Protection Agency Compliance Requirements (Stationary Emergency Spark-Ignited Generators) Purchaser's/Owner's Record Keeping Responsibilities The United States Environmental Protection Agency (EPA) and Generac Power Systems, Inc. (Generac) are pleased to explain your record keeping requirements for compliance with Subpart JJJJ- Standards of Performance for Stationary Spark Ignition Internal Combustion Engines as listed in the Electronic Code of Federal Regulations Title 40 Part 60. As the engine purchaser/owner who operates and maintains their certified emergency stationary engine and emission control system according to applicable emission related guidelines as specified in this Owner's Manual, you are required to meet the following notification and record keeping requirements to demonstrate compliance: 1) Maintain documentation that the engine is certified to meet emission standards. 2) Record keeping of maintenance conducted. 3) Record keeping of the provision allowing natural gas engines to operate using propane for a maximum of 100 hours per year as an alternate fuel solely during emergency operations provided the engine is not certified to operate on propane. 4) Meet all compliance notifications submitted to the purchaser/owner and maintain all supporting documentation. 5) Record keeping of hours of operation, including what classified the operation as emergency and how many hours are spent for non-emergency operation. For emergency engines greater than or equal to 130 HP, record keeping of hours of operation begins January 1, 2011. For emergency engines less than 130 HP, record keeping of hours of oper- ation begins January 1, 2009; engines are equipped with non-resettable hour meters to facilitate record keeping. Specific Air Quality Management or Air Pollution Control Districts may have different and additional record keeping/reporting requirements. Your permit to construct and/or operate the engine may be contingent upon compliance with those requirements. Check with your local Air Quality Management or Air Pollution Control District for specific requirements. Emergency stationary internal combustion engines (ICE) may be operated for the purpose of maintenance checks and readiness testing, provided that the tests are recommended by Federal, State or local government, Generac, or the insurance company associated with the engine. Maintenance checks and readiness testing of such units is limited to 100 hours per year. There is no time limit on the use of emer- gency stationary ICE in emergency situations. The purchaser/owner may petition the Administrator for approval of additional hours to be used for maintenance checks and readiness testing, but a petition is not required if the owner maintains records indicating that Federal, State, or local standards require maintenance and testing of emergency ICE beyond 100 hours per year. Emergency stationary ICE may operate up to 50 hours per year in non emergency situations, but those 50 hours are counted towards the 100 hours per year provided for maintenance and testing. The 50 hours per year for non-emergency situations cannot be used for peak shaving or to generate income for a facility to supply power to an electric grid or otherwise supply power as part of a financial arrangement with another entity. For purchaser/owner of emergency engines, any operation other than emergency operation, maintenance and testing, and operation in non-emergency situations for 50 hours per year, as permitted in this section is prohibited. If you operate and maintain your certified emergency stationary SI internal combustion engine and emissions control systems in accordance to the specifications and guidelines in this Owner’s Manual, EPA will not require engine performance testing. If not, your engine will be con- sidered non-certified and you must demonstrate compliance according to Subpart JJJJ - Standards of Performance for Stationary Spark Igni- tion Internal Combustion Engines as listed in the Electronic Code of Federal Regulations Title 40 Part 60. Emission-Related Installation Instructions Your certified emergency stationary engine has pre-set emission control systems or components that require no adjustment. Inspection and replacement of an emissions related component is required to be done so in accordance with the requirements cited in the United States Environmental Protection Agency Warranty Statement or can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service dealer, 1-800-333-1322 for the dealer nearest you. Failing to follow these instructions when installing a certified engine in a piece of non-road equipment violates federal law 40 CFR 1068.105 (b), subject to fines or penalties as described in the Clean Air Act. EmsnWrnty001 Revision F (04/15) ASCO®ASCO®ASCO® ASCO®ASCO®ASCO®ENGINE CONTROL CONTACTSLOAD DISCONNECT FEATURECOMMON ALARM & NOT IN AUTO SIGNALING FEATURESINPHASE TRANSFER FEATURE FOR LOAD TRANSFERSOURCE AVAILABILITY SIGNALSEXTERNAL POWER SUPPLY COMPATIBILITYLOAD CURRENT METERINGNON-AUTOMATIC (MANUAL) OPERATIONFOUR-FUNCTION SOFTWARE BUNDLEREMOTE CONTROL FEATURES ASCO® ASCO® ASCO® ASCO® ASCO®