Loading...
HomeMy WebLinkAbout26 0534 Conduit -Azt OXOBOXO LOFTS 42 Pink Row Uncasville, CT GENERAL CONTRACTOR: Dakota Partners 1264 Main Street Waltham, MA 02451 ELECTRICAL CONTRACTOR: Horton Electrical Services 97 River Road Canton, CT 06019 860‐693‐6388 Conduit 26 0534 CIVIL ENGINEER: BSC Group 300 Winding Brook Drive Glastonbury, CT 06033 STRUCTURAL ENGINEER: Morrissey Engineering, LLC 58 Essex Street Deep River, CT. 06417 ARCHITECT: Paul B. Bailey Architect, LLC. 110 Audubon Street New Haven, CT 06510 MECHANICAL/ELECTRICAL ENGINEER: Aztech Engineer, Inc. 901 Wethersfield Avenue Hartford, CT 06114 Uninsulated Connectors applications • For use in dry locations to bond EMT conduit to a box or enclosure • RACO® Steel set screw connectors provide concrete-tight connections when taped • RACO® Set screw connectors are suitable for applications above 600V product features • All steel construction insures mechanical protection for the raceway • Tri-head screws (1/2” to 2” trade sizes) may be installed using a slotted, Phillips, or Robertson head screwdriver • 2-1/2” to 4” trade sizes are also UL listed for use on Rigid/IMC conduit, allowing for design and installation flexibility • All components are zinc electroplated for corrosion protection • 1/2” to 1” trade sizes have one set screw, 1-1/4” to 4” trade sizes have two set screws • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliances 1/2” - 2” • - Standard 514B C22.2 # 18 2-1/2” - 4” • - Standard 514B U L LISTED E195969, E195970 insulatedcatalog number 2122 2002 1/2” 50 500 — 2122-8 2002-8 1/2” 1 25 IIIIIIII 2123 2003 3/4” 25 250 — 2123-8 2003-8 3/4” 1 20 IIIIIIII 2124 2004 1” 25 100 — 2124-8 2004-8 1” 1 10 IIIIIIII 2125 2005 1-1/4” — 20 — 2126 2006 1-1/2” — 20 — 2128 2008 2” — 20 — 2160 2140 2-1/2” — 5 — 2162rac 2142 3” — 1 — 2164 2144 3-1/2” — 1 — 2166 2146 4” — 1 — Set Screw Connectors – Steel unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code Set Screw Connectors – Steel 2122us 2002us 1/2” 50 250 — 2123us 2003us 3/4” 25 125 — 2124us 2004us 1” 20 100 — 2125us 2005us 1-1/4” 5 25 — 2126us 2006us 1-1/2” 5 25 — 2128us 2008us 2” — 5 — 2160us 2140us 2-1/2” — 5 — 2162us 2142us 3” — 1 — 2164us 2144us 3-1/2” — 1 — 2166us 2146us 4” — 1 — Insulated Connectors SeT SCRew CONNeCTORS - STeel see end of section (pg b91) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B3B3 EMt connEctorS Couplings applications • For use in dry locations to couple two ends of EMT conduit • RACO® Steel set screw couplings provide concrete-tight connections when taped • RACO® Set screw couplings are suitable for applications above 600V product features • All steel construction insures mechanical protection for the raceway • Tri-head screws (1/2” to 2” trade sizes) may be installed using a slotted, Phillips, or Robertson head screwdriver • 2-1/2” to 4” trade sizes are also UL listed for use on Rigid/IMC conduit, allowing for design and installation flexibility • All components are zinc electroplated for corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliances 1/2” - 2” • - Standard 514B C22.2 # 18 2-1/2” - 4” • - Standard 514B U L LISTED E195969, E195970 catalog number 2022 1/2” 50 500 — 2022-8 1/2” 1 25 IIIIIIII 2023 3/4” 25 250 — 2023-8 3/4” 1 20 IIIIIIII 2024 1” 25 100 — 2024-8 1” 1 10 IIIIIIII 2025 1-1/4” 5 25 — 2026 1-1/2” — 20 — 2028 2” — 20 — 2150 2-1/2” — 5 — 2152 3” — 1 — 2154 3-1/2” — 1 — 2156 4” — 1 — Set Screw Couplings – Steel unit cartonqty.trade size ship cartonqty.upcbar code Set Screw Couplings – Steel 2022us 1/2” 50 250 — 2023us 3/4” 25 125 — 2024us 1” 10 50 — 2025us 1-1/4” — 5 — 2026us 1-1/2” — 5 — 2028us 2” — 5 — 2150us 2-1/2” — 5 — 2152us 3” — 1 — 2154us 3-1/2” — 1 — 2156us 4” — 1 — SeT SCRew COuplINGS - STeel see end of section (pg b91) for detailed drawings » raco commercial fittinGs RACO FITTINGSB4 EMt couplingS applications • For use to bond EMT conduit to a box or enclosure • RACO® 1/2” to 4” connectors provide concrete-tight connections • RACO® Compression connectors are suitable for applications above 600V product features • All steel construction insures mechanical protection for the raceway • All components are zinc electroplated for corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliance • - Standard 514B C 22.2 # 1 U L LISTED E195970 insulatedcatalog number 2912 2902 1/2” 50 500 — 2912-8 2902-8 1/2” 1 25 IIIIIIII 2913 2903 3/4” 25 250 — 2913-8 2903-8 3/4” 1 20 IIIIIIII 2914 2904 1” 25 100 — 2914-8 2904-8 1” 1 10 IIIIIIII 2915 2905 1-1/4” 5 25 — 2916 2906 1-1/2” — 20 — 2918 2908 2” — 20 — 2960 2940 2-1/2” — 5 — 2962 2942 3” — 1 — 2964 2944 3-1/2” — 1 — 2966 2946 4” — 1 — Compression Connectors – Steel unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code Uninsulated Throat ConnectorsInsulated Throat Connectors Compression Connectors – Steel 2912us 2902us 1/2” 50 250 — 2913us 2903us 3/4” 25 125 — 2914us 2904us 1” 20 100 — 2915us 2905us 1-1/4” 5 25 — 2916us 2906us 1-1/2” 5 25 — 2918us 2908us 2” — 5 — 2960us 2940us 2-1/2” — 5 — 2962us 2942us 3” — 1 — 2964us 2944us 3-1/2” — 1 — 2966us 2946us 4” — 1 — COmpReSSION CONNeCTORS - STeel see end of section (pg b91) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B5 EMt connEctorS Couplings applications • For use in dry locations to couple two ends of EMT conduit • RACO® Steel compression couplings provide concrete-tight connections • RACO® compression couplings are suitable for applications above 600V product features • All steel construction insures mechanical protection for the raceway • All components are zinc electroplated for corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliance • - Standard 514B C 22.2 # 18 U L LISTED E195970 catalog number 2922 1/2” 50 500 — 2922-8 1/2” 1 25 IIIIIIII 2923 3/4” 25 250 — 2923-8 3/4” 1 15 IIIIIIII 2924 1” 25 100 — 2924-8 1” 1 10 IIIIIIII 2925 1-1/4” 5 25 — 2926 1-1/2” — 20 — 2928 2” — 20 — 2950 2-1/2” — 5 — 2952 3” — 1 — 2954 3-1/2” — 1 — 2956 4” — 1 — Compression Couplings – Steel unit cartonqty.trade size ship cartonqty.upcbar code Compression Couplings – Steel 2922us 1/2” 50 250 — 2923us 3/4” 25 125 — 2924us 1” 20 100 — 2925us 1-1/4” 5 25 — 2926us 1-1/2” 5 25 — 2928us 2” — 5 — 2950us 2-1/2” — 5 — 2952us 3” — 1 — 2954us 3-1/2” — 1 — 2956us 4” — 1 — see end of section (pg b92) for detailed drawings » raco commercial fittinGs RACO FITTINGSB6 COmpReSSION COuplINGS - STeel EMt couplingS applications • For use in wet locations to bond and secure EMT conduit to a box or enclosure • RACO® Raintight Steel EMT Compression Fittings have been designed to comply with the new U.L. Raintight test requirements and to comply with the requirements of the 2008 NEC 358.42 and 314.15 product features • All steel construction insures mechanical protection for the raceway • Fittings are available in 1/2” to 4” trade sizes • Zinc electroplate finish • All fittings are marked “Wet Loctations” to allow inspecting authorities to immediately determine that the installation is up to code • All connectors are supplied with a factory installed knockout seal. No need to add the expense of buying a gasket separately • No need to disassemble the fitting prior to installation. RACO Raintight Steel EMT Compression Fittings are designed so that when they come out of the carton they can be installed directly on the conduit. No need to waste time loosening compression nuts • No need for special tools to install properly. Install these fittings like any other Steel EMT Compression Fitting. No need for a torque wrench to insure proper installation compliance • - Standard 514B C 22.2 # 18 U L LISTED E195970 insulatedcatalog number 2912rt 2902rt 1/2” 50 250 — 2913rt 2903rt 3/4” 25 125 — 2914rt 2904rt 1” 15 75 — 2915rt 2905rt 1-1/4” — 20 — 2916rt 2906rt 1-1/2” — 10 — 2918rt 2908rt 2” — 10 — 2960rt 2940rt 2-1/2” — 1 — 2962rt 2942rt 3” — 1 — 2964rt 2944rt 3-1/2” — 1 — 2966rt 2946rt 4” — 1 — Compression Connectors, Raintight – Steel unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code Uninsulated Connectors Insulated Connectors see end of section (pg b91) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B7 RAINTIGHT COmpReSSION CONNeCTORS - STeel EMt connEctorS Couplings applications • For use in wet locations to couple two ends of EMT conduit • RACO® Raintight Steel EMT Compression Fittings have been designed to comply with the new U.L. Raintight test requirements and to comply with the requirements of the 2008 NEC 358.42 and 314.15 product features • All steel construction insures mechanical protection for the raceway • Fittings are available in 1/2” to 4” trade sizes • Zinc electroplate finish • All fittings are marked “Wet Loctations” to allow inspecting authorities to immediately determine that the installation is up to code • No need to disassemble the fitting prior to installation. RACO Raintight Steel EMT Compression Fittings are designed so that when they come out of the carton they can be installed directly on the conduit. No need to waste time loosening compression nuts • No need for special tools to install properly. Install these fittings like any other Steel EMT Compression Fitting. No need for a torque wrench to insure proper installation compliance • - Standard 514B C 22.2 # 18 U L LISTED E195970 catalog number 2922rt 1/2” 50 250 — 2923rt 3/4” 25 125 — 2924rt 1” 15 75 — 2925rt 1-1/4” — 20 — 2926rt 1-1/2” — 10 — 2928rt 2” — 10 — 2950rt 2-1/2” — 1 — 2952rt 3” — 1 — 2954rt 3-1/2” — 1 — 2956rt 4” — 1 — Compression Couplings – Steel unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b92) for detailed drawings » raco commercial fittinGs RACO FITTINGSB8 RAINTIGHT COmpReSSION COuplINGS - STeel EMt couplingS catalog number 2072 1/2” 25 100 — 2073 3/4” — 25 — 90˚ Short Angle Connectors – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code 90˚ Short Angle Connectors applications • To bond EMT conduit to a box or enclosure • Use RACO® 90 degree short angle connec- tors when bending conduit is not practical product features • Malleable construction insures mechanical protection for the raceway • Hex compression nuts assure easy wrench installation • All components are zinc electro plated for corrosion protection compliances • - Standard 514B see end of section (pg b94) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B17 90˚ SHORT ANGle CONNeCTORS - mAlleABle IRON EMt connEctorS die cast two-piece connectorsapplications • For use in dry locations to bond EMT conduit to a box or enclosure • RACO® 1/2” and 3/4” two-piece connectors provide concrete-tight connections die cast two-piece connectorsproduct feature • Rugged metallic construction provides mechanical protection for the raceway compliance • - Standard 514B steel combination couplinGs application • Use RACO Cat. Nos. 1352 - 1354 when coupling threaded rigid/IMC conduit to EMT steel combination couplinGs product features • Rugged metallic construction provides mechanical protection for the raceway • All steel components are zinc electro plated for corrosion protection compliance • - Standard 514B catalog number 2702 1/2” — 100 — 2703 3/4” — 50 — 1352 1/2” — 25 — 1353 3/4” — 25 — 1354 1” — 25 — Two-Piece Connectors – Die Cast Zinc unit cartonqty.trade size ship cartonqty.upcbar code Two-Piece Connectors EMT to Rigid CouplingsThreaded/Compression EMT - Rigid Couplings Threaded/Compression – Steel see end of section (pg b95) for detailed drawings » raco commercial fittinGs RACO FITTINGSB18 TwO pIeCe CONNeCTORS ANd COmBINATION COuplINGS - dIe CAST/STeel EMt two-piEcE connEctorS and couplingS catalog number 1432 1/2” — 25 — 1433 3/4” — 25 — 1434 1” — 25 — EMT - Rigid Couplings Set Screw – Steel unit cartonqty.trade size ship cartonqty.upcbar code EMT to Rigid Couplings Set Screw applications • Use RACO® Catalog numbers 1432 - 1434 when coupling unthreaded Rigid/IMC to EMT conduit product features • Rugged metallic construction provides mechanical protection • All components are zinc electro plated for corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation see end of section (pg b95) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B19 COmBINATION COuplINGS - STeel EMt couplingS application • Use RACO® Catalog numbers 1941 - 1943 or 1482 - 1484 when coupling flexible metal conduit to EMT product features • Rugged metallic construction insures mechanical protection • All steel/malleable components are zinc electro plated for corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliance • FILE E195969 catalog number 1941* 3/8” 1/2” — 25 — 1942 1/2” 1/2” — 25 — 1942-8 1/2” 1/2” 1 25 IIIIIIII 1943 3/4” 3/4” — 25 — 1943-8 3/4” 3/4” 1 20 IIIIIIII 1482 1/2” 1/2” 50 500 — 1483 3/4” 3/4” 25 250 — 1484 1” 1” 25 250 — unit cartonqty.flex size ship cartonqty. EMT - Flex Couplings Squeeze/Compression EMT - Flex CouplingsScrew-in/Compression EMT - Flex Couplings Screw-in/Compression – Die Cast Zinc upcbar code EMT - Flex Couplings Squeeze/Compression – Malleable Iron emt size *Not UL Listed see end of section (pg b95) for detailed drawings » raco commercial fittinGs RACO FITTINGSB20 COmBINATION COuplINGS - mAlleABle IRON/dIe CAST EMt coMbination couplingS catalog number unit cartonqty.rigid/imc size ship cartonqty.upcbar code Clampbacks – Malleable Iron emt size 1342 1/2” 3/4” — 100 — 1343 3/4” 1” — 100 — 1344 1” 1-1/4” — 50 — 1345 1-1/4” 1-1/2” — 25 — 1346 1-1/2” 2” — 25 — 1348 2” 2” — 10 — 1347 2-1/2” 2-1/2” — 10 — 1349 3” 3” — 10 — 1350 3-1/2” 3-1/2” — 5 — 1351 4” 4” — 5 — Clamp Backs applications • For use with RACO® 1300 Series EMT and Rigid/IMC straps to permit space between the conduit and the mounting surface • Use of clampbacks in outdoor locations can prevent the build-up of snow and rain between the conduit and the mounting surface product features • All malleable construction insures durability and mechanical protection • Zinc electro plated for added corrosion protection • Elongated bolt holes make alignment with straps easy • For use in mounting EMT conduit in wet or dry locations compliance • FILE E195968 see end of section (pg b96) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B21 ClAmp BACkS - mAlleABle IRON EMt claMp backS application • For use in mounting EMT conduit product features • All stamped steel construction insures mechanical protection • RACO® steel one hole straps snap on to the conduit, allowing the installer to easily position the strap before mounting • Oversized bolt holes make alignment of the fastener quick and easy • All straps are zinc electro plated for corrosion protection compliance • - Listed E195968 (2082 - 2088) catalog number 2082 1/2” 100 1000 — 2083 3/4” 50 500 — 2084 1” 50 500 — 2085 1-1/4” — 50 — 2086 1-1/2” — 50 — 2088 2” — 25 — 1337 2-1/2” — 25 — 1339 3” — 25 — 1340 3-1/2” — 10 — 1341 4” — 10 — 2092 1/2” — 100 — 2093 3/4” — 100 — 2094 1” — 100 — 2095 1-1/4” — 50 — 2096 1-1/2” — 50 — 2098 2” — 25 — 2239 2-1/2” — 25 — 2240 3” — 25 — 2241 3-1/2” — 25 — 2242 4” — 10 — One Hole Push-on Straps Stamped – Steel (cULus) unit cartonqty.trade size ship cartonqty.upcbar code One Hole Push-on Straps Two Hole Straps Two Hole Straps Stamped – Steel see end of section (pg b96) for detailed drawings » raco commercial fittinGs RACO FITTINGSB22 STRApS - STeel EMt StrapS catalog number 1310 2-1/2” — 10 — 1312 3” — 10 — 1314 3-1/2” — 5 — 1316 4” — 5 — 2252 1/2” 100 1000 — 2253 3/4” 100 1000 — 2254 1” 100 1000 — One Hole Straps – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code malleable-straps application • For use in mounting EMT conduit in wet or dry locations steel-straps application • For use in mounting EMT conduit malleable - straps product features • All malleable construction insures mechanical protection • Oversized bolt holes make alignment of the fastener quick and easy • All straps are zinc electro plated for corrosion protection steel - straps product feature • Stamped steel straps are pregalvanized for added corrosion protection steel - straps compliance • - LISTED E195968, E195973 • c us - (2252-2253) One Hole Straps Nail-up Straps Nail-up Straps Stamped – Steel see end of section (pg b97) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B23 STRApS - mAlleABle ANd STeel EMt StrapS Uninsulated Connectors applications • For use in dry locations to bond unthreaded rigid/IMC conduit to a box or enclosure • RACO® Steel set screw connectors are suitable for concrete-tight applications when taped product features • All steel construction insures mechanical protection for the raceway • 2-1/2” to 4” trade sizes are also UL listed for use on EMT conduit, allowing for design and installation flexibility • All components are zinc electroplated for corrosion protection compliance • - Standard 514B U L LISTED E195969 Insulated Connectors insulatedcatalog number — 3002 1/2” — 25 — — 3003 3/4” — 25 — — 3004 1” — 10 — — 3005 1-1/4” — 5 — — 3006 1-1/2” — 5 — — 3008 2” — 5 — *2160 *2140 2-1/2” — 5 — *2162rac *2142 3” — 1 — *2164 *2144 3-1/2” — 1 — *2166 *2146 4” — 1 — Set Screw Connectors – Steel unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code *Add suffix US when ordering for US Made product see end of section (pg b97) for detailed drawings » raco commercial fittinGs RACO FITTINGSB24 SeT SCRew CONNeCTORS - STeel rigid SEt ScrEw connEctorS catalog number 3022 1/2” — 25 — 3023 3/4” — 10 — 3024 1” — 5 — 3025 1-1/4” — 5 — 3026 1-1/2” — 5 — 3028 2” — 5 — *2150 2-1/2” — 5 — *2152 3” — 1 — *2154 3-1/2” — 1 — *2156 4” — 1 — Couplings – Steel unit cartonqty.trade size ship cartonqty.upcbar code applications • For use in dry locations to couple two ends of unthreaded rigid/IMC conduit • RACO® Steel set screw couplings are suitable for concrete-tight applications when taped product features • All steel construction insures mechanical protection for the raceway • 2-1/2” to 4” trade sizes are also UL listed for use on EMT conduit, allowing for design and installation flexibility • All components are zinc electroplated for corrosion protection compliance • - Standard 514B U L LISTED E195969 Couplings *Add suffix US when ordering for US made product see end of section (pg b97) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B25 SeT SCRew COuplINGS - STeel rigid couplingS applications • For use to bond unthreaded rigid/IMC conduit to a box or enclosure • RACO® 1/2” to 4” connectors and couplings provide concrete-tight connections product features • All steel/malleable iron construction insures mechanical protection for the raceway • Hex compression nuts assure easy wrench installation • All components are zinc electro plated for corrosion protection compliances • - Standard 514B U L FILE E195969 • - C22.2 #18 Insulated Connectors insulatedcatalog number 3802rac 1802 1/2” — 25 — 3803rac 1803 3/4” — 25 — 3804rac 1804 1” — 10 — 3805rac 1805 1-1/4” — 5 — 3806rac 1806 1-1/2” — 5 — 3808rac 1808 2” — 5 — — 1810 2-1/2” — 5 — — 1812 3” — 1 — — 1814 3-1/2” — 1 — — 1816 4” — 1 — Compression Connectors – Steel/Malleable Iron unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code Uninsulated Connectors see end of section (pg b98) for detailed drawings » raco commercial fittinGs RACO FITTINGSB26 COmpReSSION CONNeCTORS - STeel/mAlleABle IRON rigid coMprESSion connEctorS catalog number 1822 1/2” — 25 — 1823 3/4” — 10 — 1824 1” — 5 — 1825 1-1/4” — 5 — 1826 1-1/2” — 5 — 1828 2” — 5 — 1830 2-1/2” — 5 — 1832 3” — 1 — 1834 3-1/2” — 1 — 1836 4” — 1 — Couplings – Steel/Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code applications • For use to couple two ends of unthreaded rigid/IMC conduit • RACO® 1/2” to 4” couplings provide concrete-tight connections product features • All steel/malleable iron construction insures mechanical protection for the raceway • Hex compression nuts assure easy wrench installation • All components are zinc electro plated for corrosion protection compliance • - Standard 514B U L FILE E195969 • - C22.2 #18 Couplings see end of section (pg b98) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B27 COmpReSSION COuplINGS - STeel/mAlleABle IRON rigid coMprESSion couplingS application • For use with threaded rigid/IMC conduit • 90 degree short elbows are ideal for use in tight locations where bending of conduit is not practical product features • All malleable iron construction insures mechanical protection for the raceway • All components are zinc electro plated for corrosion protection compliances • - Standard 514B 90 Degree Short Elbows catalog number 1722 1/2” — 50 — 1723 3/4” — 25 — 90 Degree Short Elbows – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b98) for detailed drawings » raco commercial fittinGs RACO FITTINGSB28 SHORT elBOwS - mAlleABle IRON rigid SHort ElbowS catalog number 2662 1/2” 10 100 — 2663 3/4” 5 50 — 2664rac 1” — 25 — 2652 1/2” 10 100 — 2653 3/4” 5 50 — 2654 1” — 25 — 2655 1-1/4” — 20 — 90 Degree Handy-Ells Threaded Connectors – Die Cast Zinc unit cartonqty.trade size ship cartonqty.upcbar code applications • For use with threaded rigid/IMC conduit to bond conduit to a box or enclosure, or to couple two ends of rigid/IMC conduit • Use handy ells when bending conduit is not practical product features • Gasket and cover included compliance • - Standard 514B U L LISTED E195969 • - C22.2 #18 90 Degree Handy Ells Threaded Connectors 90 Degree Handy-Ells Threaded Couplings – Die Cast Zinc 90 Degree Handy Ells Threaded Couplings see end of section (pg b99) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B29 HANdy ellS - dIe CAST rigid Handy EllS catalog number 1502 1/2” — 25 — 1503 3/4” — 25 — 1504 1” — 5 — 1505 1-1/4” — 5 1506 1-1/2” — 5 — 1508 2” — 5 — 1510 2-1/2” — 4 — 1512 3” — 4 — 1514 3-1/2” — 2 — 1516 4” — 2 — 1520 5” — 1 — 1524 6” — 1 — Three-Piece Couplings – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code applications • For use with threaded rigid/IMC conduit • Use couplings to couple conduit ends when the conduit cannot be turned • RACO® Three-piece couplings provide concrete-tight connections product features • Malleable iron construction insures mechanical protection for the raceway • All components are zinc electro plated for corrosion protection compliance • c us UL LISTED E195969 Three-piece Couplings Three-Piece Couplings – Steel see end of section (pg b99) for detailed drawings » raco commercial fittinGs RACO FITTINGSB30 THRee-pIeCe COuplINGS - mAlleABle IRON rigid couplingS catalog number 1352 1/2” — 25 — 1353 3/4” — 25 — 1354 1” — 25 — 1432 1/2” — 25 — 1433 3/4” — 25 — 1434 1” — 25 — Rigid-EMT Couplings Threaded/Compression – Steel unit cartonqty.trade size ship cartonqty.upcbar code applications • For use when coupling rigid/IMC to EMT • Use RACO® Cat. Nos. 1352 - 1354 when coupling threaded rigid/IMC conduit to EMT • Use RACO® Cat. Nos. 1432 - 1434 when coupling unthreaded rigid/IMC conduit to EMT product features • All steel construction insures mechanical protection • All components are zinc electro plated for corrosion protection • UPC bar code fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliance • - Standard 514B (1432 - 1434 only) UL FILE E195969 Rigid to EMT CouplingsThreaded/Compression Rigid-EMT Couplings Set Screw – Steel Rigid to EMT CouplingsSet Screw see end of section (pg b100) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B31 COmBINATION COuplINGS - STeel rigid coMbination couplingS application • Use RACO® Cat. Nos. 1552 - 1554 when coupling flexible metal conduit to threaded rigid/IMC product features • All malleable iron construction insures mechanical protection for the raceway • All components are zinc electro plated for corrosion protection compliance • Rigid to Flex Couplings Threaded/Squeeze catalog number 1552 1/2” — 100 — 1553 3/4” — 25 — 1554 1” — 25 — Rigid - Flex Couplings – Malleable Iron Squeeze/Threaded unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b100) for detailed drawings » raco commercial fittinGs RACO FITTINGSB32 COmBINATION COuplINGS - mAlleABle IRON rigid coMbination couplingS catalog number 1702 1/2” — 25 — 1703 3/4” — 25 — 1704 1” — 25 — 1705 1-1/4” — 10 1706 1-1/2” — 10 — 1708 2” — 10 — 1710 2-1/2” — 5 — 1712 3” — 2 — 1714 3-1/2” — 2 — 1716 4” — 2 — Threaded Hubs Insulated Throat – Die Cast Zinc unit cartonqty.trade size ship cartonqty.upcbar code applications • For use with threaded rigid/IMC conduit to connect and bond conduit to a threadless opening in a box or enclosure • May be used in wet or dry locations product features • Rugged metallic construction insures mechanical protection • Insulated throat protects wires and reduces wire pulling effort • O-ring seals the assembly and provides a raintight seal compliance • - Standard 514B UL LISTED E195969 • - C22.2 #18 Threaded Hubs Insulated see end of section (pg b101) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B33 THReAded HuBS - dIe CAST rigid tHrEadEd HubS application • For use with threaded rigid/IMC conduit to reduce the size of a female hub to accommodate a smaller size of conduit or male threaded hub product features • Rugged steel construction insures mechanical protection of the raceway • Zinc electro plated for corrosion protection compliance • c us UL LISTED E195969 Reducing Bushings catalog number 1141 1/2” - 3/8” — 100 — 1142 3/4” - 1/2” — 100 — 1143 1” - 1/2” — 50 — 1144 1” - 3/4” — 50 1145 1-1/4” - 1/2” — 50 — 1146 1-1/4” - 3/4” — 50 — 1147 1-1/4” - 1” — 50 — 1148 1-1/2” - 1/2” — 50 — 1149 1-1/2” - 3/4” — 50 — 1150 1-1/2” - 1” — 50 — 1151 1-1/2” - 1-1/4” — 50 — 1152 2” - 1/2” — 25 — 1153 2” - 3/4” — 25 — 1154 2” - 1” — 25 1155 2” - 1-1/4” — 25 — 1156 2” - 1-1/2” — 25 — Reducing Bushings – Steel unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b101) for detailed drawings » raco commercial fittinGs RACO FITTINGSB34 ReduCING BuSHINGS - STeel rigid rEducing buSHingS catalog number 1160 2-1/2” - 1-1/4” — 10 — 1161 2-1/2” - 1-1/2” — 10 — 1162 2-1/2” - 2” — 10 — 1168 3” - 2” — 10 1169 3” - 2-1/2” — 5 — 1175 3”-1/2” - 2” — 5 — 1176 3”-1/2” - 2-1/2” — 5 — 1177 3”-1/2” - 3” — 5 — 1185 4” - 3” — 5 — 1186 4” - 3-1/2” — 5 — Reducing Bushings – Iron unit cartonqty.trade size ship cartonqty.upcbar code application • For use with threaded rigid/IMC conduit to reduce the size of a female hub to accommodate a smaller size of conduit or male threaded hub product features • Rugged iron construction insures mechanical protection of the raceway • Zinc electro plated for corrosion protection compliance • c us UL LISTED E195969 Reducing Bushings see end of section (pg b102) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B35 ReduCING BuSHINGS - IRON rigid rEducing buSHingS application • For use in dry locations on threaded rigid/ IMC conduit to secure conduit to a box or enclosure product features • All steel construction insures mechanical protection • Zinc electro plated for corrosion protection compliances (excludes non-ul) • - Standard 514B U L LISTED E195969 • - C22.2 #18 catalog number 1001 3/8” 100 1000 — 1002 1/2” 100 1000 — 1003 3/4” 100 1000 — 1004 1” — 100 1005 1-1/4” — 50 — 1006 1-1/2” — 50 — 1008 2” — 50 — 1010 2-1/2” — 30 — 1012 3” — 25 — 1014 3-1/2” — 15 — 1016 4” — 10 — 1020 5” — 8 — 1024 6” — 8 — 1192 1/2” 100 1000 — 1193 3/4” 100 1000 — 1194 1” — 100 — 1195 1-1/4” — 50 1196 1-1/2” — 50 — 1198 2” — 50 — 1197 2-1/2” — 30 — 1199 3” — 25 — 1200 3-1/2” — 15 — 1201 4” — 10 — 1219 5” — 8 — 1220 6” — 8 — Locknuts – Steel unit cartonqty.trade size ship cartonqty.upcbar code Locknuts (1002 - 1220) Locknuts (1001) Non-UL Locknuts – Steel see end of section (pg b102) for detailed drawings » raco commercial fittinGs RACO FITTINGSB36 lOCkNuTS - STeel rigid locknutS catalog number 1242 1/2” — 50 — 1243 3/4” — 50 — 1244 1” — 25 — 1245 1-1/4” — 25 1246 1-1/2” — 25 — 1248 2” — 20 — 1250 2-1/2” — 10 — 1252 3” — 10 — 1254 3-1/2” — 5 — 1256 4” — 5 — Bonding Locknuts – Steel unit cartonqty.trade size ship cartonqty.upcbar code application • For use on threaded rigid/IMC conduit • Use bonding locknuts when additional locking and grounding connections are required in applications where severe vibration is encountered product features • All steel construction insures mechanical protection • Zinc electro plated for corrosion protection compliances • - Standard 514B UL LISTED E195975 • - C22.2 #18 Bonding Locknuts see end of section (pg b103) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B37 BONdING lOCkNuTS - STeel rigid bonding locknutS Sealing Locknuts application • For use on threaded rigid/IMC conduit to pro- vide a liquidtight seal against water and oil • RACO® sealing locknuts may be used with either sheet metal or cast enclosures product features • Fused-in-place gasket guarantees a liquidtight seal • Use RACO sealing locknut as an economical alternative to a threaded enclosure connector • All steel construction insures mechanical protection • Zinc electro plated for corrosion protection compliances • - Standard 514B (1202 - 1210) UL FILE E195969 • - C22.2 #18 (1202 - 1211) catalog number 1202 1/2” — 100 — 1203 3/4” — 100 — 1204 1” — 50 — 1205 1-1/4” — 50 1206 1-1/2” — 25 — 1208 2” — 25 — 1207 2-1/2” — 30 — 1209 3” — 25 — 1210 3-1/2” — 15 — 1211 4” — 10 — Sealing Locknuts – Steel unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b103) for detailed drawings » raco commercial fittinGs RACO FITTINGSB38 SeAlING lOCkNuTS - STeel rigid SEaling locknutS Insulating Bushings application • For use on threaded rigid/IMC conduit • RACO® Bushings provide a smooth rounded surface at the entrance of raceways product feature • Insulating bushings are made of high impact polypropylene that is temperature rated at 105° C compliances • - Standard 514B UL FILE 195973 catalog number 1402 1/2” 100 400 — 1403 3/4” 100 400 — 1404 1” 50 200 — 1405 1-1/4” — 25 1406 1-1/2” — 25 — 1408 2” — 25 — 1410 2-1/2” — 10 — 1412 3” — 10 — 1414 3-1/2” — 5 — 1416 4” — 5 — 1420 5” — 5 — 1424 6” — 5 — Insulating Bushings – Polypropylene unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b104) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B39 INSulATING BuSHINGS - pOlypROpyleNe buSHingS catalog number 1102rac 1/2” — 100 — 1103 3/4” — 100 — 1104 1” — 50 — 1105 1-1/4” — 50 1106 1-1/2” — 50 — 1108 2” — 50 — 1110 2-1/2” — 30 — 1112 3” — 10 — 1114 3-1/2” — 10 — 1116 4” — 10 — Bushings – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code application • For use on threaded rigid/IMC conduit • RACO® Bushings provide a smooth rounded surface at the entrance of raceways product features • Malleable iron construction insures mechanical protection • Zinc electro plated for corrosion protection compliances • - Standard 514B U L LISTED E195969 • - C22.2 #18 Bushings see end of section (pg b104) for detailed drawings » raco commercial fittinGs RACO FITTINGSB40 BuSHINGS - mAlleABle IRON buSHingS catalog number 1132* 1/2” — 100 — 1133* 3/4” — 50 — 1134* 1” — 25 — 1135 1-1/4” — 25 1136 1-1/2” — 25 — 1138 2” — 10 — 1126 2-1/2” — 10 — 1127 3” — 5 — 1128 3-1/2” — 5 — 1129 4” — 5 — Insulated Bushings – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code application • For use on threaded rigid/IMC conduit to provide a smooth rounded surface at the entrance of raceways product features • Insuliner temperature rated at 150° C • Malleable iron construction insures mechanical protection for the raceway • Zinc electro plated for corrosion protection • 1/2” to 1” trade sizes are also available in die cast zinc compliances • - Standard 514B U L LISTED E195969 • - C22.2 #18 Insulated Bushings *Available in Die Cast Zinc. Add suffix DC when ordering. see end of section (pg b104) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B41 INSulATed BuSHINGS - mAlleABle IRON inSulatEd buSHingS Insulated Grounding Bushings Lay-in Lug application • For use on threaded rigid/IMC conduit to provide a means of grounding conduit through an insulated bushing product features • Lay-in and Feed-thru lug styles provide an easy means of inserting a ground wire • Dual rated aluminum grounding lugs may be used with copper or aluminum grounding conductors • Insuliner temperature rated at 150° C • Malleable iron construction insures mechanical protection for the raceway • Zinc electro plated for corrosion protection compliances • - Standard 514B • - C22.2 #18 catalog number 1212 1/2” — 100 #14 Sol. #4 Str. — 1213 3/4” — 100 #14 Sol. #4 Str. — 1214 1” — 50 #14 Sol. #4 Str. — 1215 1-1/4” — 25 #14 Sol. #4 Str. — 1216 1-1/2” — 25 #14 Sol. #4 Str. — 1218 2” — 10 #14 Sol. #4 Str. — 1290 2-1/2” — 10 #14 Sol. #1/0 Str. — 1292rac 3” — 5 #14 Sol. #1/0 Str. — 1294 3-1/2” — 5 #6 Str. #250 MCM — 1296 4” — 5 #6 Str. #250 MCM — 1262dc 1/2” — 100 #14 Sol. #4 Str. — 1263dc 3/4” — 100 #14 Sol. #4 Str. — 1264dc 1” — 50 #14 Sol. #4 Str. — 1222 1/2” — 100 #14 Sol. #4 Str. — 1223 3/4” — 100 #14 Sol. #4 Str. — 1224 1” — 50 #14 Sol. #4 Str. — 1225 1-1/4” — 25 #14 Sol. #4 Str. — 1226 1-1/2” — 25 #14 Sol. #4 Str. — 1228 2” — 10 #14 Sol. #4 Str. — 1230 2-1/2” — 10 #14 Sol. #1/0 Str. — 1232rac 3” — 5 #14 Sol. #1/0 Str. — 1234 3-1/2” — 5 #6 Str. #250 MCM — 1236 4” — 5 #6 Str. #250 MCM — unit cartonqty.trade size ship cartonqty.upcbar code grounding wire capacity min.max. 150° Insulated Grounding Bushings - Lay-in Lug – Malleable Iron 150° Insulated Grounding Bushings - Feed-thru Lug – Malleable Iron Insulated Grounding Bushings Feed-thru Lug 150° Insulated Grounding Bushings - Lay-in Lug – Die Cast Zinc see end of section (pg b105) for detailed drawings » raco commercial fittinGs RACO FITTINGSB42 150° INSulATed GROuNdING BuSHINGS - mAlleABle IRON inSulatEd buSHingS catalog number unit cartonqty.trade size ship cartonqty.upcbar code application • For use in mounting rigid/IMC conduit in wet or dry locations • RACO® Rigid/IMC conduit straps are suitable for use on liquidtight flexible metal conduit and liquidtight flexible nonmetallic conduit (type B) product features • All stamped steel construction insures mechanical protection • RACO® steel one-hole straps snap on to conduit, allowing the installer to easily position the strap before mounting • All straps are zinc electro plated for corrosion protection One Hole Push-on Straps 1332 1/2” 100 500 — 1333 3/4” 100 500 — 1334 1” 50 250 — 1335 1-1/4” — 25 — 1336 1-1/2” — 25 — 1338 2” — 25 — 1337 2-1/2” — 25 — 1339 3” — 25 — 1340 3-1/2” — 10 — 1341 4” — 10 — One Hole Push-on Straps – Stamped Steel see end of section (pg b106) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B43 STRApS - STeel rigid StrapS catalog number 2232 1/2” — 100 — 2233 3/4” — 100 — 2234 1” — 100 — 2235 1-1/4” — 100 2236 1-1/2” — 50 — 2238 2” — 25 — 2239 2-1/2” — 25 — 2240 3” — 25 — 2241 3-1/2” — 25 — 2242 4” — 10 — 2245-2 5” — 5 — 2246-2 6” — 5 — Two Hole Straps – Stamped Steel unit cartonqty.trade size ship cartonqty.upcbar code application • For use in mounting rigid/IMC conduit in wet or dry locations • RACO® Rigid/IMC conduit straps are suitable for use on liquidtight flexible metal conduit and liquidtight flexible nonmetallic conduit (type B) product features • All stamped steel construction insures mechanical protection • All straps are zinc electro plated for corrosion protection Two Hole Straps see end of section (pg b106) for detailed drawings » raco commercial fittinGs RACO FITTINGSB44 STRApS - STeel rigid StrapS One Hole Straps application • For use in mounting rigid/IMC conduit in wet or dry locations • RACO® Rigid/IMC conduit straps are suitable for use on liquidtight flexible metal conduit and liquidtight flexible nonmetallic conduit (type B) product features • All malleable construction insures mechanical protection • All straps are zinc electro plated for corrosion protection catalog number 1301 3/8” — 100 — 1302 1/2” — 100 — 1303 3/4” — 100 — 1304 1” — 50 1305 1-1/4” — 25 — 1306 1-1/2” — 25 — 1308 2” — 25 — 1310 2-1/2” — 10 — 1312 3” — 10 — 1314 3-1/2” — 5 — 1316 4” — 5 — One Hole Straps – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code see end of section (pg b106) for detailed drawings » raco commercial fittinGs www.Hubbell-RTB.com B45 TwO HOle STRApS - mAlleABle IRON rigid StrapS Clamp Backs ApplicAtion • For use with RACO® 1300 Series straps to permit space between the conduit and the moutning surface • Use of clamp backs in outdoor locations can prevent the buildup of snow and rain between the conduit and the mounting surface product feAtures • All malleable construction insures durability and mechanical protection • Elongated bolt holes make alignment with straps easy compliAnce • UL LISTED E195968 catalognumber 1342 1/2” 3/4” — 100 — 1343 3/4” 1” — 100 — 1344 1” 1-1/4” — 50 — 1345 1-1/4” 1-1/2” — 25 1346 1-1/2” 2” — 25 — 1348 2” 2” — 10 — 1347 2-1/2” 2-1/2” — 10 — 1349 3” 3” — 10 — 1350 3-1/2” 3-1/2” — 5 — 1351 4” 4” — 5 — unit cartonqty. trade size ship cartonqty.upcbar coderigid size emt size Clamp Backs – Malleable Iron see end of section (pg b107) for detailed drawings » rAco commerciAl fittings RACO FITTINGSB46 ClAmp BACkS - mAlleABle IRON rigid clamp backs raco commercial fittinGs www.Hubbell-RTB.com B47 raco commercial fittinGs UninsulatedSteel/Malleable Iron applications • For use in outdoor or indoor locations on flexible metallic liquidtight conduit and Type B flexible nonmetallic liquidtight conduit • Use to positively bond the conduit to a box or enclosure • RACO® liquidtight connectors are suitable for use in Class I, Div 2; Class II, Div 1 & 2; and Class III, Div 1 & 2 hazardous locations product features • Patented split gland-ring is designed to slip onto the conduit quickly and to grip the jacket of the conduit, speeding installation, assuring a perfect seal, and preventing pullouts • All components are reusable - RACO® liquidtight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquidtight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground • All steel/iron components are zinc electro plated for added corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation bodies • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron nuts • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron compliances • - Standard 514B U L LISTED E195969 • - C22.2 #18 InsulatedSteel/Malleable Iron insulatedcatalog number 3511rac* — 3/8” 25 100 — — 3401 3/8” 50 200 — — 3401-8 3/8” 1 15 IIIIIIII 3512rac 3402 1/2” 50 200 — 3512-8 3402-8 1/2” 1 15 IIIIIIII 3513rac 3403 3/4” 25 100 — 3513-8 3403-8 3/4” 1 10 IIIIIIII 3514rac 3404 1” — 10 — 3514-8 3404-8 1” 1 5 IIIIIIII 3515rac 3405 1-1/4” — 10 — 3516 3406 1-1/2” — 5 — 3518 3408 2” — 5 — 3520 3410 2-1/2” — 1 — 3522 3412 3” — 1 — 3524 3414 3-1/2” — 1 — 3526 3416 4” — 1 — Straight - Insulated and Uninsulated – Steel/Mallealble Iron unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code Uninsulated Steel/Malleable Iron Insulated Steel/Malleable Iron 3561* 3441* 3/8” — 25 — 3562 3442 1/2” — 25 — 3563 3443 3/4” — 25 — 3564 3444 1” — 10 — 3565 3445 1-1/4” — 10 — 3566 3446 1-1/2” — 5 — 3568 3448 2” — 5 — * 1/2” Trade size hub 45˚ CONNeCTORS insulatedcatalog number unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code 45˚ Insulated and Uninsulated – Steel/Malleable Iron see end of section (pg b107-b108) for detailed drawings » STRAIGHT CONNeCTORS liquidtigHt conduit and cord connEctorS UninsulatedSteel/Malleable IronInsulatedSteel/Malleable Iron insulatedcatalog number 90˚ Insulated and Uninsulated – Steel/Malleable Iron unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code 3541rac* 3421* 3/8” 25 100 — — 3421-8* 3/8” 1 15 IIIIIIII 3542 3422 1/2” 25 100 — 3542-8 3422-8 1/2” 1 15 IIIIIIII 3543 3423 3/4” 25 100 — 3543-8 3423-8 3/4” 1 10 IIIIIIII 3544 3424 1” — 10 — 3544-8 3424-8 1” 1 5 IIIIIIII 3545 3425 1-1/4” — 10 — 3546 3426 1-1/2” — 5 — 3548 3428 2” — 5 — 3550 3430 2-1/2” — 1 — 3552 3432 3” — 1 — 3556 3436 4” — 1 — * 1/2” Trade size hub ApplicAtions • For use in outdoor or indoor locations on flexible metallic liquidtight conduit and Type B flexible nonmetallic liquidtight conduit • Use to positively bond the conduit to a box or enclosure • RACO® liquidtight connectors are suitable for use in Class I, Div 2; Class II, Div 1 & 2; and Class III, Div 1 & 2 hazardous locations product FeAtures • Patented split gland-ring is designed to slip onto the conduit quickly and to grip the jacket of the conduit, speeding installation, assuring a perfect seal, and preventing pullouts • All components are reusable - RACO® liquidtight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquidtight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground • All steel/iron components are zinc electro plated for added corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation Bodies • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron nuts • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron compliAnces • - Standard 514B U L LISTED E195969 • - C22.2 #18 see end of section (pg b108) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB48 90˚ CONNeCTORS liquidtight conduit and cord connectors ApplicAtions • For use in outdoor or indoor locations on flexible metallic liquidtight conduit and Type B flexible nonmetallic liquidtight conduit • Use to positively bond the conduit to a box or enclosure product FeAtures • Patented split gland-ring is designed to slip onto the conduit quickly gripping the jacket of the conduit, speeding installation, assuring a perfect seal, preventing pullouts • All components are reusable - RACO® liquid-tight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquid- tight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground compliAnce • Conduit Fittings 3HNNUninsulatedDie Cast Zinc Insulated Die Cast Zinc UninsulatedDie Cast ZincInsulatedDie Cast Zinc 3511dc* — 3/8” 50 200 — — 3401dc* 3/8” 50 200 — 3512dc 3402dc 1/2” 50 200 — 3513dc 3403dc 3/4” 25 100 — 3514dc 3404dc 1” — 10 — 3515dc 3405dc 1-1/4” — 10 — 3516dc 3406dc 1-1/2” — 5 — 3518dc 3408dc 2” — 5 — 3520dc — 2-1/2” — 1 — 3522dc — 3” — 1 — 3524dc — 3-1/2” — 1 — 3526dc — 4” — 1 — Straight - Insulated and Uninsulated – Die Cast Zinc insulatedcatalog number unit cartonqty.trade sizeuninsulatedcatalog number ship cartonqty.upcbar code 3541dc* 3421dc* 3/8” 25 100 — 3542dc 3422dc 1/2” 25 100 — 3543dc 3423dc 3/4” 25 100 — 3544dc 3424dc 1” — 10 — 3545dc 3425dc 1-1/4” — 10 — 3546dc 3426dc 1-1/2” — 5 — 3548dc 3428dc 2” — 5 — 3550dc — 2-1/2” — 1 — 3552dc — 3” — 1 — 3554dc — 3-1/2” — 1 — 3556dc — 4” — 1 — * 1/2” Trade size hub 90˚ Insulated and Uninsulated – Die Cast Zinc 90˚ CONNeCTORS STRAIGhT CONNeCTORS rAco commerciAl Fittings www.hubbell-RTB.com B49B49 liquidtight conduit and cord connectors see end of section (pg b107-b108) for detailed drawings » Insulated w/Ground LugSteel/Malleable Iron ApplicAtions • For use in outdoor or indoor locations on flexible metallic liquidtight conduit, when installation of a copper or aluminum external bonding jumper is required • RACO® grounding liquidtight connectors are suitable for use in Class I, Div 2; Class II, Div 1 & 2; and Class III, Div 1 & 2 hazardous locations product FeAtures • Patented split gland-ring is designed to slip onto the conduit quickly and to grip the jacket of the conduit, speeding installation, assuring a perfect seal, and preventing pullouts • All components are reusable - RACO® liquidtight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquidtight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground • All metallic components are zinc electro plated for added corrosion protection Bodies • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron nuts • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron compliAnces • - Standard 514B U L LISTED E195969 • - C22.2 #18 catalog number 3511-3* 3/8” — 25 #14 SOL. #4 STR. — 3512-3 1/2” — 25 #14 SOL. #4 STR. — 3513-3 3/4” — 25 #14 SOL. #4 STR. — 3514-3 1” — 10 #14 SOL. #4 STR. — 3515-3 1-1/4” — 10 #14 SOL. #4 STR. — 3516-3 1-1/2” — 5 #14 SOL. #4 STR. — 3518-3 2” — 5 #14 SOL. #4 STR. — 3520-3 2-1/2” — 1 #14 SOL. #1/0 STR. — 3522-3 3” — 1 #14 SOL. #1/0 STR. — 3524-3 3-1/2” — 1 #6 STR. #250 MCM — 3526-3 4” — 1 #6 STR. #250 MCM — unit cartonqty.trade size ship cartonqty.upcbar code Straight - Insulated with Ground Lug – Steel/Malleable Iron grounding wire capacity minimum maximum * 1/2” Trade size hub STRAIGhT, GROuNdING Type CONNeCTORS see end of section (pg b108) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB50 liquidtight conduit and cord connectors ApplicAtions • For use in outdoor or indoor locations on flexible metallic liquidtight conduit, when installation of a copper or aluminum external bonding jumper is required • RACO® grounding liquidtight connectors are suitable for use in Class I, Div 2; Class II, Div 1 & 2; and Class III, Div 1 & 2 hazardous locations product FeAtures • Patented split gland-ring is designed to slip onto the conduit quickly and to grip the jacket of the conduit, speeding installation, assuring a perfect seal, and preventing pullouts • Malleable iron castings mate with other components perfectly without strain or distortion • All components are reusable - RACO® liquidtight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquidtight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground • All metallic components are zinc electro plated for added corrosion protection Bodies • 3/8” to 2” Malleable Iron nuts • 3/8” to 1” Steel, 1-1/4” to 2” Malleable Iron compliAnces • - Standard 514B U L LISTED E195969 • - C22.2 #18 Insulated w/Ground LugSteel/Malleable Iron catalog number 3561-3* 3/8” — 25 #14 SOL. #4 STR. — 3562-3 1/2” — 25 #14 SOL. #4 STR. — 3563-3 3/4” — 25 #14 SOL. #4 STR. — 3564-3 1” — 10 #14 SOL. #4 STR. — 3565-3 1-1/4” — 10 #14 SOL. #4 STR. — 3566-3 1-1/2” — 5 #14 SOL. #4 STR. — 3568-3 2” — 5 #14 SOL. #4 STR. — unit cartonqty.trade size ship cartonqty.upcbar code 45˚ - Insulated with Ground Lug – Steel/Malleable Iron grounding wire capacity minimum maximum * 1/2” Trade size hub see end of section (pg b109) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B51 45˚ INSulATed CONNeCTOR, GROuNdING Type liquidtight conduit and cord connectors Insulated w/Ground LugSteel/Malleable Iron ApplicAtions • For use in outdoor or indoor locations on flexible metallic liquidtight conduit, when installation of a copper or aluminum external bonding jumper is required • RACO® grounding liquidtight connectors are suitable for use in Class I, Div 2; Class II, Div 1 & 2; and Class III, Div 1 & 2 hazardous locations product FeAtures • Patented split gland-ring is designed to slip onto the conduit quickly and to grip the jacket of the conduit, speeding installation, assuring a perfect seal, and preventing pullouts • Malleable iron castings mate with other components perfectly without strain or distortion • All components are reusable - RACO® liquidtight connectors may be easily disassembled and reused after years of service • Sealing washer (included) provides a liquidtight seal when terminating the connector in a threadless opening • Heavy duty locknut included with every RACO® liquidtight connector assures continuity of ground • All metallic components are zinc electro plated for added corrosion protection Bodies • 3/8” to 4” Malleable Iron nuts • 3/8” to 1” Steel, 1-1/4” to 4” Malleable Iron compliAnces • - Standard 514B U L LISTED E195969 • - C22.2 #18 catalog number 3541-3* 3/8” — 25 #14 SOL. #4 STR. — 3542-3 1/2” — 25 #14 SOL. #4 STR. — 3543-3 3/4” — 25 #14 SOL. #4 STR. — 3544-3 1” — 10 #14 SOL. #4 STR. — 3545-3 1-1/4” — 10 #14 SOL. #4 STR. — 3546-3 1-1/2” — 5 #14 SOL. #4 STR. — 3548-3 2” — 5 #14 SOL. #4 STR. — 3550-3 2-1/2” — 1 #14 SOL. #4 STR. — 3552-3 3” — 1 #14 SOL. #4 STR. — 3556-3 4” — 1 #14 STR. #4 STR. — unit cartonqty.trade size ship cartonqty.upcbar code 90˚ - Insulated with Ground Lug – Steel/Malleable Iron grounding wire capacity minimum maximum * 1/2” Trade size hub see end of section (pg b109) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB52 90˚ INSulATed CONNeCTOR, GROuNdING Type liquidtight conduit and cord connectors catalog number 2452 1/2” 50 100 — 2452-8 1/2” 2 per bag 25 bags of 2 IIIIIIII 2453 3/4” 25 50 — 2453-8 3/4” 2 per bag 20 bags of 2 IIIIIIII 2454 1” 25 50 — 2454-8 1” 2 per bag 10 bags of 2 IIIIIIII 2455 1-1/4” 5 25 — 2456 1-1/2” 5 25 — 2458 2” 5 25 — Sealing Washers* – Steel unit cartonqty.trade size ship cartonqty.upcbar code ApplicAtions • For use whenever a positive seal is re- quired between the shoulder of a fitting and an enclosure product FeAtures • One piece construction assures proper installation - no need to worry about aligning multiple components • Steel ring is zinc electro plated for added corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliAnces • - Standard 514B U L LISTED E195973 • - C22.2 #18 Sealing Washers* * One-piece steel ring and neoprene gasket, raintight see end of section (pg b109) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B53 SeAlING wASheRS - STeel liquidtight conduit and cord connectors catalog number 3301 3/8”* — 50 — 3302 1/2” — 50 — 3302-8 1/2” 1 25 IIIIIIII 3303 3/4” — 25 — 3303-8 3/4” 1 20 IIIIIIII 3304 1” — 25 — 3304-8 1” 1 5 IIIIIIII 3305 1-1/4” — 25 — 3306 1-1/2” — 25 — 3308 2” — 10 — 3310 2-1/2” — 1 — 3312 3” — 1 — 3314 3-1/2” — 1 — 3316 4” — 1 — Straight Squeeze Connector, Insulated – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code ApplicAtions • For use in dry locations to bond flexible metal conduit to a box or enclosure product FeAtures • All malleable construction insures mechanical protection for the raceway • Electro zinc plated for added corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliAnce • UL Listed E195969 * For 1/2” knockout Straight Squeeze ConnectorsInsulated Straight Squeeze ConnectorsUninsulated 2101 3/8”* — 50 — 2102 1/2” — 50 — 2102-8 1/2” 1 25 IIIIIIII 2103 3/4” — 25 — 2103-8 3/4” 1 20 IIIIIIII 2104 1” — 25 — 2104-8 1” 1 5 IIIIIIII 2105 1-1/4” — 25 — 2106 1-1/2” — 25 — 2108 2” — 10 — 2110 2-1/2” — 1 — 2112 3” — 1 — 2114 3-1/2” — 1 — 2116 4” — 1 — Straight Squeeze Connector, Uninsulated – Malleable Iron see end of section (pg b112) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B61 STRAIGhT Squeeze CONNeCTORS - mAlleABle IRON flexible metal conduit fittings * For 1/2” knockout ApplicAtion • For use in dry locations to bond flexible metal conduit to a box or enclosure product FeAture • Rugged metallic construction insures mechanical protection for the raceway compliAnces • - Standard 514B U L FILE E195969 • - C22.2 #18 catalog number 2661 3/8”* 100 1000 — 2611 3/8”* 25 250 — Clamp Type Connector – Die Cast Zinc unit cartonqty.trade size ship cartonqty.upcbar code Clamp Type Connector Duplex Connector Duplex Connector – Die Cast Zinc ApplicAtions • For use when coupling flexible metal conduit to rigid/MC conduit • Use RACO® Cat. Nos. 1552 - 1554 when coupling threaded rigid/IMC conduit to flexible metal conduit product FeAtures • Rugged metallic construction insures mechanical protection • Steel/malleable components are electro zinc plated for added corrosion protection compliAnce UL FILE E195969 • Flex - emt ApplicAtion • For use when coupling flexible metal conduit to EMT conduit product FeAtures • Rugged metallic construction insures mechanical protection • Steel/malleable components are electro zinc plated for added corrosion protection • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliAnces • - Standard 514B - C22.2 #18 catalog number 1552 1/2” 25 100 — 1553 3/4” — 25 — 1554 1” — 25 — Flex to Rigid Couplings – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code Flex - Rigid Couplings COmBINATION COuplINGS - mAlleABle IRON catalog number 1941* 3/8” 1/2” — 25 — 1942 1/2” 1/2” — 25 — 1942-8 1/2” 1/2” 1 25 IIIIIIII 1943 3/4” 3/4” — 25 — 1943-8 3/4” 3/4” 1 20 IIIIIIII unit cartonqty.flexsize ship cartonqty.upcbar code Flex - EMT Squeeze Couplings * Not UL Listed emtsize Flex-EMT Squeeze Couplings – Malleable Iron see end of section (pg b116) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB66 ClAmp Type CONNeCTORS ANd duplex CONNeCTORS - dIe CAST zINC flexible metal conduit fittings comBinAtion couplings ApplicAtions • For use when coupling flexible metal conduit to EMT conduit • Use RACO® Cat. Nos. 1482 - 1484 when coupling flexible metal conduit to EMT conduit product FeAture • Rugged metallic construction insures mechanical protection compliAnces • - Standard 514B - C22.2 #18 nAil-up strAps ApplicAtion • For use in mounting flexible metal conduit, armored cable, and MC cable product FeAture • Stamped steel straps are pregalvanized for added corrosion protection nAil-up strAps compliAnce • Anti-sHort BusHings ApplicAtion • Anti-short bushings are for use with Armored cable and Flexible Metal Conduit. The bushings protect the conductors during pulling from sharp cut ends of the conduit. product FeAtures • Easy to use - just insert into the end of the conduit • Lightweight, one-piece plastic construction resists corrosion • Economical solution for preventing costly damage catalog number 1482 1/2” 1/2” 50 500 — 1483 3/4” 3/4” 25 250 — 1484 1” 1” 25 250 — unit cartonqty.flexsize ship cartonqty.upcbar code * For 3/8” flexible metal conduit. Also suitable for AC and MC cable. ** For 1/2” flexible metal conduit. Also suitable for AC and MC cable. emtsize Flex-EMT Couplings, Screw-In/Compression – Die Cast Zinc catalog number 2252 3/8” * 100 1000 — 2253 1/2” ** 100 1000 — Nail-Up Straps – Steel unit cartonqty.trade size ship cartonqty.upcbar code Nail-Up Straps Flex - EMT Screw-In/Compression Couplings catalog number unit cartonqty.trade size ship cartonqty.upcbar code 1440b35 5/16” 35 10 bags of 35 IIIIIIII 1441b35 3/8” 35 10 bags of 35 IIIIIIII 1447b35 7/16” 35 5 bags of 35 IIIIIIII 1442b20 1/2” 20 5 bags of 20 IIIIIIII 1443b16 3/4” 16 4 bags of 16 IIIIIIII Anti-short Bushings – Plastic Anti-short Bushings BuShINGS NAIl-up STRApS see end of section (pg b116 & 117) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B67 COmBINATION COuplINGS - dIe CAST zINC flexible metal conduit fittings ApplicAtions • For use in dry locations to bond armored cable to a box or enclosure product FeAtures • Rugged metallic construction insures mechanical protection for the raceway compliAnces • - Standard 514B UL Listed E195969 (excludes 2191) • - C22.2 #18 Set Screw Connector catalog number 2661j 3/8” 100 1000 — 2191k 3/8” 50 500 — 2192 1/2” 25 250 — 2193 3/4” 25 250 — 2194 1” 10 100 — Clamp Type Connector – Die Cast Zinc unit cartonqty.trade size ship cartonqty.upcbar code Squeeze Type Connector – Die Cast Zinc Clamp Type Connector Squeeze Type Connector 2511j 3/8” 100 1000 — Set Screw Connector – Die Cast Zinc jFor 1/2” knockout. 1/2” Hub size suitable for use with steel armored cable sizes 2#14, 3#14, 2#12, 3#12, 2#10 and 3#10 all with ground wire. kFor 1/2” knockout. Suitable for use with steel armored cable and flexible metal conduit. see end of section (pg b117) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB68 uNINSulATed CONNeCTORS - dIe CAST zINC armored cable connectors ApplicAtion • For use in dry locations to bond armored cable to a box or enclosure product FeAtures • Rugged metallic construction insures mechanical protection for the raceway • UPC bar coded fittings are individually polybagged with a preprinted UPC-A bar code and packaged in pre-scored tear top cartons for an attractive presentation compliAnce • UL Listed E195969 (excludes 3201) * For 1/2” knockout catalog number 3201 3/8” * — 50 — 3202 1/2” — 25 — 3202-8 1/2” 1 25 IIIIIIII 3203 3/4” — 25 — 3203-8 3/4” 1 20 IIIIIIII 2201 3/8” * — 50 — 2202 1/2” 25 100 — 2202-8 1/2” 1 25 IIIIIIII 2203 3/4” — 25 — 2203-8 3/4” 1 20 IIIIIIII 90˚ Squeeze Connectors, Insulated Throat – Malleable Iron unit cartonqty.trade size ship cartonqty.upcbar code 90˚ Squeeze Connectors, Uninsulated Throat – Malleable Iron 90˚ Squeeze ConnectorsUninsulated90˚ Squeeze ConnectorsInsulated ApplicAtions • For use in dry locations to bond armored cable to a box or enclosure product FeAtures • Rugged metallic construction insures mechanical protection for the raceway compliAnces • - Standard 514B UL Listed E195969 • - C22.2 #18 catalog number unit cartonqty.trade size ship cartonqty.upcbar code 2691 3/8” * 50 500 — 2692 1/2” 25 250 — 2693 3/4” 10 100 — 2611 3/8” * 25 250 — 90˚ Squeeze Type Connector, Uninsulated – Die Cast Zinc 90˚ Squeeze Type ConnectorUninsulated Duplex Connector Duplex Connector – Die Cast Zinc 90˚ ANd duplex CONNeCTORS - dIe CAST zINC see end of section (pg b118) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B69 90˚ CONNeCTORS - mAlleABle IRON armored cable connectors ApplicAtions • Anti-short bushings are for use with Armored cable and Flexible Metal Conduit. The bushings protect the conductors during pulling from sharp cut ends of the conduit. product FeAtures • Easy to use - just insert into the end of the conduit • Lightweight, one-piece plastic construction resists corrosion • Economical solution for preventing costly damage catalog number unit cartonqty.trade size ship cartonqty.upcbar code 1440b35 5/16” 35 10 bags of 35 IIIIIIII 1441b35 3/8” 35 10 bags of 35 IIIIIIII 1447b35 7/16” 35 5 bags of 35 IIIIIIII 1442b20 1/2” 20 5 bags of 20 IIIIIIII 1443b16 3/4” 16 4 bags of 16 IIIIIIII Anti-short Bushings – Plastic Anti-short Bushings STRAp - STeel ApplicAtions • For use in mounting MC and AC cables in dry locations product FeAtures • All steel construction ensures mechanical protection • Zinc electro plated for corrosion protection catalog number unit cartonqty.trade size ship cartonqty.upcbar code 2081 3/8” 100 1000 — One Hole Strap – Steel One Hole Strap new! new see end of section (pg b118) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB70 BuShINGS armored cable connectors redi-loc® connectors - steel catalog number 2700 1/2” 50 500 — 2700-8 1/2” 1 25 IIIIIIII 2700aJ 1/2” 50 500 — 2700aJ-8 1/2” 1 25 IIIIIIII 2701 3/4” 25 250 — 2701-8 3/4” 1 20 IIIIIIII unitcrtn.qty.cable size shipcrtn.qty. upcbarcode 2700, 2700-8, 2700AJ, 2700AJ-8, 2701, 2701-8 2720 1/2” 50 500 2720aJ 1/2” 50 500 — tradesize REDI-LOC® Cable Connectors – Steel and Nylon (Bushing) REDI-LOC® II Cable Connectors – Steel and Nylon (Bushing) 2720, 2720AJ mci: al: .434 - .530, mci: steel .400 - .530, mci-a: steel (.440 - .510), ac: steel/al: 14-2 (.400) to 12-3 mci: steel/al: .475 - .575, mci-a: al .430 - .560 mci-a: steel .470 - .540, ac: steel/al: 14-2 to 12-4 (.475 - .575) mci: al: .590 - .680, mci: steel .565 - .659, ac: steel/al: 10-3 to 8-3 (.590) 2715 1/2” mci: al: 450 - .545, mci: steel .425 - .550, mcc: al: .380 - .550, 25 250 — mcc: ac: 14-1 to 12-3 w/Grnd., Alum. and Steel REDI-LOC® Duplex Cable Connector – Steel and Nylon (Bushing) 2715 ac: al: 14-2 to 12-2 ac: steel 14-2 to 12-3, mc: mci: steel/al: 14-2 to 12-3, mci-a: al: 14-2 to 10-2 hcF: al: 12-2 to 10-2 cable range dia.: .370” Dia. min. to .520” max. ac: steel & al 14-3 to 10-3, mc: mci: steel/al: 12-2 to 10-3, mci-a: steel/al: 12-3 to 10-3 hcF: al: 12-3 to 10-3, 3/8” rWF mc: steel/al: cable range dia.: .460” Dia. min. to .600” max. ApplicAtions • RACO® REDI-LOC® metal-clad cable connect-or is designed for use in dry locations for connecting MCI, MCI-A, AC and HCF cable into a box or enclosure • RACO® REDI-LOC® II is used to terminate and secure MC, MCI, MCI-A and armored cable into a 1/2” knockout product FeAtures • No tools needed to assemble to end of cable or to install into box or enclosure • Preassembled anti-short bushing will not fall out during installation • Easy installation - push the cable into the fit-ting, push connector into the box or enclosure • Can be removed without tools and is reusable • Rugged one piece design • Fits all standard 1/2” knockouts • Made from steel, and nylon (bushing) • Zinc electroplated for corrosion protection • Tri-lingual (English, Spanish and French installation instructions included in each unit carton) • UPC bar coded fittings are individually polybagged with a preprinted UPC A bar code and packaged n prescored tear top cartons for an attractive presentation US Patent 5,731,543 (REDI-LOC) US Patent Pending (REDI-LOC II) ApplicAtions • RACO® REDI-LOC® Duplex connectors are for use in dry locations to connect MCI, MCI-A , AC and HCF cable to a box or enclosure product FeAtures • Tri-head screw/clamp design can accom-modate two runs of MCI, AC and HCF cable. Connector can be installed by using a slotted, Phillips or Robertson head screw-driver. • Reusable design - installation can be reversed just as easily as it was originally installed • Preassembled anti-short bushing will not fall out during installation • Made from steel, and nylon (bushing) • Zinc electroplated for corrosion protection • Tri-lingual (English, Spanish and French in- stallation instructions included in each unit carton compliAnce (All) • FILE E195966 US Patents 6,034,326 and 6,020,557 see end oF section (pg b119) For detailed draWings » rAco commerciAl Fittings www.Hubbell-rtB.com B71 metal clad cable connectors 2800 1/2” 50 500 — 2801 3/4” 25 250 — ApplicAtions • For use in dry locations for connecting MCI, MCI-A (2800 only), AC, and HCF cable into a box or enclosure product FeAtures • Easy to install, just tilt, insert and snap down • Tri-head screw/clamp design - connector can be installed by using a slotted, Phillips or Robertson head screwdriver • Integral insuliner provides maximum wire protection • Durable all-steel construction • Zinc electroplated for corrosion protection compliAnce • LISTED UL Listed E195966 catalog number unit cartonqty.trade size ship cartonqty.upcbar code Connector Cable Connector – Steel cABle type AC Steel HCF Steel AC Aluminum MCI Steel MCI Aluminum MC Aluminum MCI-A Aluminum 2800 - 1/2” Ko 14-2, 14-3, 14-4, 12-2, 12-3, 12-4, 10-2, 10-3 14-2, 14-3, 12-2, 12-3, 10-2 14-2, 14-3, 14-4, 12-2, 12-3, 12-4 14-2, 14-3, 14-4, 12-2, 12-3, 12-4, 10-2 14-2, 14-3, 14-4, 12-2, 12-3, 12-4, 10-2 14-3, 14-4, 12-2, 12-3, 12-4, 10-2, 10-3 12-8, 10-3, 10-4, 10-6 selection cHArt 2801 - 3/4” Ko 10-4, 10-5, 8-3, 8-4, 6-3 — 10-4, 8-3, 8-4 10-3, 10-4, 8-2, 8-3 10-3, 10-4, 8-2 — — see end of section (pg b119) for detailed drawings » rAco commerciAl Fittings RACO FITTINGSB72 CONNeCTORS - SCRew Type STeel metal clad cable connectors ApplicAtions • For use in dry locations to connect MC/MCI cable to a box or enclosure product FeAtures • Rugged metallic construction insure mechanical protection for the raceway compliAnces • - Standard 514B UL Listed E195969 • - C22.2 #18 2661 3/8” * 100 1000 — 2611 3/8” * 25 250 — catalog number unit cartonqty.trade size ship cartonqty.upcbar code Duplex Cable Connector – Die Cast Zinc Clamp Type Cable Connector – Die Cast Zinc diAmeter .277” - .375” .365” - .510” .345” - .525” .455” - .575” .435” - .547” .410” - .500” .460” - .538” .438” - .560” 1/2” HuB size For mc cABle - selection cHArt * For 1/2” knockout Clamp Type Connector Duplex Connector clAmp type - Part No. 2661 Regular Aluminum Corrugated Aluminum Corrugated Aluminum Smooth Aluminum Interlocked Steel Interlocked Aluminum Smooth Aluminum Interlocked Steel Interlocked duplex - Part No. 2611 see end of section (pg b120) for detailed drawings » rAco commerciAl Fittings www.hubbell-RTB.com B73 ClAmp Type ANd duplex CONNeCTORS - dIe CAST zINC metal clad cable connectors Galvanized Rigid Conduit (GRC) • Hot-dip galvanized for excellent corrosion resistance • High strength ductile steel for long life and easy bending • Smooth, continuous raceways for fast wire pulling • Kwik-Release End Cap to protect threads • True Color™ GRC special orders available • Listed to Safety Standard UL 6 • Manufactured in accordance with ANSI C80.1 • Available in sizes 1/2 (16) - 6 (155) Kwik-Couple Galvanized Rigid Conduit (GRC) • Similar Benefits to standard GRC Conduit* • Factory installed Kwik-Couple™ couplings are available on GRC conduit Just line up the ends, spin the coupling forward onto the next piece and wrench tighten. It’s that easy! • No separate couplings to purchase, inventory or install • Kwik-Release End Cap to protect threads • True Color™ Kwik-Couple® GRC special orders available • Manufactured in accordance with ANSI C80.1 • Available in sizes 2 1/2 (63) - 5 (129) *Kwik-Couple GRC does not contain a listing for wet locations and is not approved for Class I Division I locations. Chart on the following page Galvanized Rigid Conduit (GRC) and Kwik-Couple® GRC in mm in mm lb kg ft m 1/2 16 0.840 21.34 0.104 2.64 82 37.2 2500 762.5 3/4 21 1.050 26.67 0.107 2.72 109 49.4 2000 610.0 1 27 1.315 33.40 0.126 3.20 161 73.0 1250 381.3 1 1/4 35 1.660 42.16 0.133 3.38 218 98.9 900 274.5 1 1/2 41 1.900 48.26 0.138 3.51 263 119.3 800 244.0 2 53 2.375 60.33 0.146 3.71 350 158.8 600 183.0 2 1/2 63 2.875 73.03 0.193 4.90 559 253.6 370 112.9 3 78 3.500 88.90 0.205 5.21 727 329.8 300 91.5 3 1/2 91 4.000 101.60 0.215 5.46 880 399.2 250 76.3 4 103 4.500 114.30 0.225 5.72 1030 467.2 200 61.0 5 129 5.563 141.30 0.245 6.22 1520 689.5 150 45.8 6 155 6.625 168.28 0.266 6.76 1785 809.7 100 30.5 Galvanized Rigid Conduit (GRC) Listed to UL 6, manufactured in accordance with ANSI C80.1 1 Tolerances: Trade Size 1/2 to 1-1/2: ±0.015” (0.38mm); Trade Size 2-6: ±1% Length equals 10 ft. (3.05m) with a tolerance of +/- .25 in. (6.35mm) 2 For information only. Not a requirement of the UL standard. * NEMA RN-3 Standard Quality, Long Lasting Heavy Duty Steel Conduit For Faster Installations Use the Kwik-Couple GRC Connection * U.S. Patent Numbers 7,404,582 and 7,726,001. Trade Size Metric Designator Approximate Weight Per 100 Ft. (30.5M) Outside Diameter1 Nominal Wall Thickness2 Quantity in Master Bundle* Kwik-Couple Rigid Elbows • Also available with pre-installed Kwik-Couple Couplings • Made to order, contact us for lead times Project Information Company Name: Address: City: State & Zip: Phone: Project Name: City: State: NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com Galvanized Rigid Conduit (GRC) and Kwik-Couple® GRC FEATURES & SPECIFICATIONS NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 KWIK-COUPLE AVAILABLE Trade Size 2-1/2 to 5 Full Electrical System Protection Manufactured from mild steel, Allied’s Rigid Conduit is highly resistant to damage from impact yet ductile to facilitate bending. The 3/4” taper NPT threads (ANSI B1.20.1) are full cut and hot galvanized after cutting. Color-coded end cap thread protectors keep the threads clean, sharp and also provide instant trade size recognition. Even sizes are color-coded blue, 1/2 sizes black, and 1/4 sizes red. Coatings Hot-dip galvanized inside and out to provide galvanic corrosion protection. Also topcoated with a compatible organic layer to protect against white rust. The inside surface is evenly coated for wire-pulling ease, even through multiple 90° bends. EMI Shielding Allied Rigid Steel Conduit is very effective in reducing the effects of electromagnetic field levels for encased power distribution circuits, shielding computers and other sensitive electronic equipment from the effects of electromagnetic interference. Visit www.alliedeg.com to obtain the GEMI (Grounding and Electro-Magnetic Interference) software analysis program. Codes & Standards Compliance Standard Galvanized Rigid Steel Conduit produced by Allied is precision manufactured for dependable, long-lasting value and ultimate protection for electrical conductors. Covered by article 344 of the National Electrical Code® (NEC), rigid steel conduit is highly resistant to damage from impact. It can be installed in all occupancies and locations, including Class I Division 1 hazardous locations. Rigid steel conduit is recognized as an equipment grounding conductor in Section 250.118 of the NEC. It is listed to Underwriters Laboratories Safety Standard UL 6 and is manufactured to ANSI C80.1, both of which have been adopted as Federal Specifications in lieu of WWC 581. Kwik-Couple Rigid steel conduit is listed to UL 6 and UL 514B and is manufactured in accordance with ANSI C80.1. Kwik-Couple Rigid Steel conduit is Listed for Concrete-tight applications. Installation of Rigid Metal Conduit shall be in accordance with the National Electrical Code and UL General Information card #DYIX. Master bundles conform to NEMA standard RN2. Specification Data To specify, Rigid Steel Conduit and Kwik-Couple Rigid Steel Conduit include the following: Rigid Steel Conduit shall be hot-dip galvanized and manufactured by Allied Tube & Conduit. Threads shall be hot galvanized after cutting. Rigid steel conduit shall be listed to UL Safety Standard 6 by a nationally- recognized testing laboratory with follow up service. It shall be manufactured in accordance with ANSI C80.1. Note: Federal specification WW-C-581, Class 1, Type A has been superseded by UL Standard 6, which has been adopted by the federal government. in mm in mm lb kg ft m 2 1/2 63 2.875 73.03 0.193 4.90 559 253.6 400 121.9 3 78 3.500 88.90 0.205 5.21 727 329.8 300 91.4 3 1/2 91 4.000 101.60 0.215 5.46 880 399.2 250 76.2 4 103 4.500 114.30 0.225 5.72 1030 467.2 200 61.0 5 129 5.563 141.30 0.245 6.22 1400 635.0 150 45.7 Kwik-Couple (GRC) UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 1 Tolerances: Trade Size 2-1/2 to 5: ± 1% 2 For information only. Not a requirement of the UL standard. Trade Size Metric Designator Approximate Weight Per 100 Ft. (30.5M) Outside Diameter1 Nominal Wall Thickness2 Bundle Quantity NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Couplings & Elbows Trade Size Metric Designator Nominal O.D. (A)2 Length (B)1 Threads Per Inch1 Approximate Weight Per 100 Pieces Standard Package in mm in mm lb kg 1/2 16 1.01 25.7 1 5/8 41.3 14 12 5.4 100 3/4 21 1.25 31.8 1 41/64 41.7 14 18 8.2 50 1 27 1.53 38.7 1 31/32 50.0 11 1/2 30 13.6 30 1 1/4 35 1.87 47.5 2 1/32 51.6 11 1/2 37 16.8 25 1 1/2 41 2.16 54.7 2 1/16 52.4 11 1/2 52 23.6 25 2 53 2.65 67.3 2 1/8 54.0 11 1/2 72 32.7 20 2 1/2 63 3.25 82.6 3 3/16 81.0 8 170 77.1 1 3 78 3.87 98.3 3 5/16 84.1 8 210 95.3 1 3 1/2 91 4.50 114.3 3 13/32 86.5 8 340 154.2 1 4 103 4.88 123.8 3 33/64 89.3 8 300 136.1 1 5 129 6.00 152.4 3 61/64 100.4 8 475 215.5 1 6 155 7.20 182.9 4 1/4 108.0 8 765 347.0 1 Galvanized Rigid Conduit (GRC) Couplings Manufactured to Underwriters Laboratory Safety Standards UL 6 Manufactured in accordance with ANSI C80.1 GRC Nipples & Couplings A = Diameter B = Length 1Mimimum requirement as per UL Standard Galvanized Rigid Conduit (GRC) 90 Degree Elbows Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Trade Size Metric Designator Radius (A)1 Offset (B)2 Straight (D)1 Approximate Weight Per 100 Pieces Standard Package in mm in mm in mm lb kg 1/2 16 4 102 5 7/8 149 1 1/2 38 68 30.8 50 3/4 21 4 1/2 114 7 178 1 1/2 38 109 49.4 50 1 27 5 3/4 146 8 3/4 222 1 7/8 48 201 91.2 25 1 1/4 35 7 1/4 184 10 3/4 273 2 51 336 152.4 20 1 1/2 41 8 1/4 210 12 1/4 311 2 51 460 208.7 15 2 53 9 1/2 241 14 1/2 368 2 51 729 330.7 10 2 1/2 63 10 1/2 267 17 432 3 76 1374 623.2 1 3 78 13 330 19 5/8 498 3 1/8 79 2045 927.6 1 3 1/2 91 15 381 22 3/4 578 3 1/4 83 2860 1297.3 1 4 103 16 406 23 7/8 606 3 3/8 86 3519 1596.2 1 5 129 24 610 34 7/8 886 3 5/8 92 6942 3148.9 1 6 155 30 762 45 1/2 1156 3 3/4 95 11960 5425.1 1 15 3022.5 45 60 90 GRC Elbow - Dimensions A = Radius B = Oset C = Straight 1Mimimum requirement as per UL Standard 2For information only, not a requirement as per UL Standard Sizes 2 1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) B B D D A B A KWIK-COUPLE ELBOWS AVAILABLE by special order in Trade Size 2-1/2 to 5 NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Elbows Trade Size Metric Designator Radius (A)1 Offset (B)2 Offset (C)2 Straight (D) 1 Approximate Weight Per 100 Pieces Standard Package in mm in mm in mm in mm lb kg 1/2 16 4 102 7 178 2 7/8 73 1 1/2 38 55 24.9 50 3/4 21 4 1/2 114 7 7/8 200 3 1/4 83 1 1/2 38 82 37.2 50 1 27 5 3/4 146 9 5/8 244 4 102 1 7/8 48 148 67.1 25 1 1/4 35 7 1/4 184 11 1/8 283 4 5/8 117 2 51 232 105.2 20 1 1/2 41 8 1/4 210 13 1/8 333 5 3/8 137 2 51 329 149.2 15 2 53 9 1/2 241 15 3/4 400 6 1/2 165 2 51 525 238.1 10 2 1/2 63 10 1/2 267 17 1/2 445 7 1/4 184 3 76 932 422.8 1 3 78 13 330 21 7/8 556 9 229 3 1/8 79 1515 687.2 1 3 1/2 91 15 381 26 1/8 664 10 7/8 276 3 1/4 83 2200 997.9 1 4 103 16 406 26 1/4 667 10 7/8 276 3 3/8 86 2575 1168.0 1 5 129 24 610 35 7/8 911 14 7/8 378 3 5/8 92 4783 2169.6 1 6 155 30 762 43 3/8 1102 18 457 3 3/4 95 7590 3442.8 1 Galvanized Rigid Conduit (GRC) 45 Degree Elbows Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Galvanized Rigid Conduit (GRC) Large Radius 90 Degree Elbows Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Trade Size Metric Designator Radius (A)Offset (B)2 Straight (D)2 Approximate Weight Per 100 Pieces in mm in mm in mm lb kg 1 27 12 305 20 5/8 524 8 5/8 219 483 219.1 1 27 15 381 24 1/4 616 9 1/4 235 564 255.8 1 27 18 457 27 7/8 708 9 7/8 251 644 292.1 1 27 24 610 34 5/8 879 10 5/8 270 792 359.3 1 27 30 762 41 1041 11 279 926 420.0 1 27 36 914 46 3/4 1187 10 3/4 273 1047 474.9 1 27 42 1067 54 1372 12 305 1208 547.9 1 27 48 1219 61 1/4 1556 13 1/4 337 1369 621.0 1 1/4 35 12 305 20 5/8 524 8 5/8 219 654 296.7 1 1/4 35 15 381 24 1/4 616 9 1/4 235 763 346.1 1 1/4 35 18 457 27 7/8 708 9 7/8 251 872 395.5 1 1/4 35 24 610 34 5/8 879 10 5/8 270 1072 486.3 1 1/4 35 30 762 41 1041 11 279 1254 568.8 1 1/4 35 36 914 46 3/4 1187 10 3/4 273 1417 642.8 1 1/4 35 42 1067 54 1372 12 305 1635 741.6 1 1/4 35 48 1219 61 1/4 1556 13 1/4 337 1853 840.5 15 3022.5 45 60 90 GRC Elbow - Dimensions A = RadiusB = OsetC = Straight 1Mimimum requirement as per UL Standard 2For information only, not a requirement as per UL Standard Sizes 2 1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) 2For information only, not a requirement as per UL Standard Chart continued on the next page Shipped in palletized cartons or bulk. Also available in the following Degrees (90°, 60°, 30°, 22-1/2°, 15° & 11-1/4°) 15 3022.5 45 60 90 GRC Elbow - Dimensions A = Radius B = Oset C = Straight D D B A B B C D D A KWIK-COUPLE ELBOWS AVAILABLE by special order in Trade Size 2-1/2 to 5 NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Elbows Galvanized Rigid Conduit (GRC) Large Radius 90 Degree Elbows (continued) Listed UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Trade Size Metric Designator Radius (A)Offset (B)2 Straight (D)2 Approximate Weight Per 100 Pieces in mm in mm in mm lb kg 1 1/2 41 12 305 20 5/8 524 8 5/8 219 789 357.9 1 1/2 41 15 381 24 1/4 616 9 1/4 235 921 417.8 1 1/2 41 18 457 27 7/8 708 9 7/8 251 1052 477.2 1 1/2 41 24 610 34 5/8 879 10 5/8 270 1293 586.5 1 1/2 41 30 762 41 1041 11 279 1512 685.8 1 1/2 41 36 914 46 3/4 1187 10 3/4 273 1710 775.7 1 1/2 41 42 1067 54 1372 12 305 1973 895.0 1 1/2 41 48 1219 61 1/4 1556 13 1/4 337 2236 1014.2 2 53 15 381 24 1/4 616 9 1/4 235 1225 555.7 2 53 18 457 27 7/8 708 9 7/8 251 1400 635.0 2 53 24 610 30 3/8 772 6 3/8 162 1473 668.2 2 53 30 762 41 1041 11 279 2013 913.1 2 53 36 914 46 3/4 1187 10 3/4 273 2275 1031.9 2 53 42 1067 54 1372 12 305 2625 1190.7 2 53 48 1219 61 1/4 1556 13 1/4 337 2975 1349.5 2 1/2 63 18 457 24 3/8 619 6 3/8 162 1910 866.4 2 1/2 63 24 610 31 1/8 791 7 1/8 181 2422 1098.6 2 1/2 63 30 762 37 1/2 953 7 1/2 191 2888 1310.0 2 1/2 63 36 914 44 3/4 1137 8 3/4 222 3447 1563.6 2 1/2 63 42 1067 54 1372 12 305 4193 1901.9 2 1/2 63 48 1219 61 1/4 1556 13 1/4 337 4752 2155.5 3 78 15 381 24 1/4 616 9 1/4 235 2545 1154.4 3 78 18 457 24 3/8 619 6 3/8 162 2484 1126.7 3 78 24 610 33 1/8 841 9 1/8 232 3393 1539.1 3 78 30 762 38 5/8 981 8 5/8 219 3892 1765.4 3 78 36 914 46 7/8 1191 10 7/8 276 4741 2150.5 3 78 42 1067 54 1372 12 305 5453 2473.5 3 78 48 1219 60 1/4 1530 12 1/4 311 6058 2747.9 3 78 60 1524 75 7/8 1927 15 7/8 403 7634 3462.8 3 1/2 91 18 457 26 3/8 670 8 3/8 213 3300 1496.9 3 1/2 91 24 610 35 1/8 892 11 1/8 283 4400 1995.8 3 1/2 91 30 762 38 1/2 978 8 1/2 216 4693 2128.7 3 1/2 91 36 914 47 1194 11 279 5757 2611.4 3 1/2 91 42 1067 54 1372 12 305 6600 2993.8 3 1/2 91 48 1219 60 1/4 1530 12 1/4 311 7333 3326.2 4 103 18 457 27 3/8 695 9 3/8 238 4034 1829.8 4 103 24 610 35 1/8 892 11 1/8 283 5150 2336.0 4 103 30 762 39 3/8 1000 9 3/8 238 5644 2560.1 4 103 36 914 47 1194 11 279 6738 3056.4 4 103 42 1067 54 1372 12 305 7725 3504.1 4 103 48 1219 60 1/4 1530 12 1/4 311 8583 3893.2 4 103 60 1524 75 7/8 1927 15 7/8 403 10815 4905.7 2For information only, not a requirement as per UL Standard Chart continued on the next page Shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) 15 3022.5 45 60 90 GRC Elbow - Dimensions A = RadiusB = OsetC = Straight B B A D D KWIK-COUPLE AVAILABLE Trade Size 2-1/2 to 5 by special order NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Elbows & Nipples Galvanized Rigid Conduit (GRC) Large Radius 90 Degree Elbows (continued) Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Trade Size Metric Designator Radius (A)Offset (B)2 Straight (D)2 Approximate Weight Per 100 Pieces in mm in mm in mm lb kg 5 129 36 914 50 3/4 1289 14 3/4 375 10033 4551.0 5 129 48 1219 65 1/4 1657 17 1/4 438 12833 5821.0 5 129 60 1524 75 7/8 1927 15 7/8 403 14700 6667.9 6 155 36 914 50 3/4 1289 14 3/4 375 13187 5981.6 6 155 48 1219 65 1/4 1657 17 1/4 438 16867 7650.9 6 155 60 1524 75 7/8 1927 15 7/8 403 19320 8763.6 15 3022.5 45 60 90 GRC Elbow - Dimensions A = RadiusB = OsetC = Straight Galvanized Rigid Conduit (GRC) Nipples Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 Trade Size Metric Designator Length (A)Total Thread Length (B)1 Threads Per Inch1 Approximate Weight Per 100 Pieces Standard Package in mm in mm lb kg 1/2 16 (Close) 1 1/8 29 0.78 19.8 14 6 2.7 25 1/2 16 1 1/2 38 0.78 19.8 14 8 3.6 25 1/2 16 2 51 0.78 19.8 14 12 5.4 25 1/2 16 2 1/2 64 0.78 19.8 14 15 6.8 25 1/2 16 3 76 0.78 19.8 14 19 8.6 25 1/2 16 3 1/2 89 0.78 19.8 14 22 10.0 25 1/2 16 4 102 0.78 19.8 14 26 11.8 25 1/2 16 5 127 0.78 19.8 14 33 15.0 25 1/2 16 6 152 0.78 19.8 14 40 18.1 25 1/2 16 8 203 0.78 19.8 14 54 24.5 25 1/2 16 10 254 0.78 19.8 14 68 30.8 25 1/2 16 12 305 0.78 19.8 14 82 37.2 25 3/4 21 (Close) 1 3/8 35 0.79 20.1 14 9 4.1 25 3/4 21 1 1/2 38 0.79 20.1 14 10 4.5 25 3/4 21 2 51 0.79 20.1 14 14 6.4 25 3/4 21 2 1/2 64 0.79 20.1 14 19 8.6 25 3/4 21 3 76 0.79 20.1 14 24 10.9 25 3/4 21 3 1/2 89 0.79 20.1 14 28 12.7 25 3/4 21 4 102 0.79 20.1 14 34 15.4 25 3/4 21 5 127 0.79 20.1 14 43 19.5 25 3/4 21 6 152 0.79 20.1 14 52 23.6 25 3/4 21 8 203 0.79 20.1 14 73 33.1 25 3/4 21 10 254 0.79 20.1 14 89 40.4 25 3/4 21 12 305 0.79 20.1 14 109 49.4 25 1Mimimum requirement as per UL Standard Chart continued on the next page A tolerance of minus one thread applies to Total length of Thread 2For information only, not a requirement as per UL Standard Shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) GRC Nipples & Couplings A = DiameterB = Length B A B B A D D KWIK-COUPLE AVAILABLE Trade Size 2-1/2 to 5 by special order NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Nipples Trade Size Metric Designator Length (A)Total Thread Length (B)1 Threads Per Inch1 Approximate Weight Per 100 Pieces Standard Package in mm in mm lb kg 1 27 (Close) 1 1/2 38 0.98 24.9 11 1/2 16 7.3 25 1 27 2 51 0.98 24.9 11 1/2 22 10.0 25 1 27 2 1/2 64 0.98 24.9 11 1/2 28 12.7 25 1 27 3 76 0.98 24.9 11 1/2 36 16.3 25 1 27 3 1/2 89 0.98 24.9 11 1/2 43 19.5 25 1 27 4 102 0.98 24.9 11 1/2 49 22.2 25 1 27 5 127 0.98 24.9 11 1/2 64 29.0 25 1 27 6 152 0.98 24.9 11 1/2 78 35.4 25 1 27 8 203 0.98 24.9 11 1/2 109 49.4 25 1 27 10 254 0.98 24.9 11 1/2 138 62.6 25 1 27 12 305 0.98 24.9 11 1/2 166 75.3 25 1 1/4 35 (Close) 1 5/8 41 1.01 25.7 11 1/2 22 10.0 25 1 1/4 35 2 51 1.01 25.7 11 1/2 28 12.7 25 1 1/4 35 2 1/2 64 1.01 25.7 11 1/2 37 16.8 25 1 1/4 35 3 76 1.01 25.7 11 1/2 47 21.3 25 1 1/4 35 3 1/2 89 1.01 25.7 11 1/2 55 24.9 25 1 1/4 35 4 102 1.01 25.7 11 1/2 66 29.9 25 1 1/4 35 5 127 1.01 25.7 11 1/2 84 38.1 25 1 1/4 35 6 152 1.01 25.7 11 1/2 100 45.4 25 1 1/4 35 8 203 1.01 25.7 11 1/2 136 61.7 25 1 1/4 35 10 254 1.01 25.7 11 1/2 176 79.8 40 1 1/4 35 12 305 1.01 25.7 11 1/2 216 98.0 30 1 1/2 41 (Close) 1 3/4 44 1.03 26.2 11 1/2 28 12.7 25 1 1/2 41 2 51 1.03 26.2 11 1/2 34 15.4 25 1 1/2 41 2 1/2 64 1.03 26.2 11 1/2 44 20.0 25 1 1/2 41 3 76 1.03 26.2 11 1/2 56 25.4 25 1 1/2 41 3 1/2 89 1.03 26.2 11 1/2 68 30.8 25 1 1/2 41 4 102 1.03 26.2 11 1/2 80 36.3 25 1 1/2 41 5 127 1.03 26.2 11 1/2 103 46.7 25 1 1/2 41 6 152 1.03 26.2 11 1/2 122 55.3 50 1 1/2 41 8 203 1.03 26.2 11 1/2 170 77.1 40 1 1/2 41 10 254 1.03 26.2 11 1/2 216 98.0 30 1 1/2 41 12 305 1.03 26.2 11 1/2 260 117.9 20 2 53 (Close) 2 51 1.06 26.9 11 1/2 44 20.0 25 2 53 2 1/2 64 1.06 26.9 11 1/2 59 26.8 25 2 53 3 76 1.06 26.9 11 1/2 72 32.7 25 2 53 3 1/2 89 1.06 26.9 11 1/2 88 39.9 40 2 53 4 102 1.06 26.9 11 1/2 103 46.7 40 2 53 5 127 1.06 26.9 11 1/2 132 59.9 40 2 53 6 152 1.06 26.9 11 1/2 160 72.6 30 2 53 8 203 1.06 26.9 11 1/2 220 99.8 20 2 53 10 254 1.06 26.9 11 1/2 285 129.3 20 2 53 12 305 1.06 26.9 11 1/2 335 152.0 15 Galvanized Rigid Conduit (GRC) Nipples (continued) Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 1Mimimum requirement as per UL Standard Chart continued on the next page A tolerance of minus one thread applies to Total length of Thread GRC Nipples & Couplings A = Diameter B = Length B A NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Galvanized Rigid Conduit (GRC) Nipples 1Mimimum requirement as per UL Standard A tolerance of minus one thread applies to Total length of Thread Trade Size Metric Designator Length (A)Total Thread Length (B)1 Threads Per Inch 1 Approximate Weight Per 100 Pieces Standard Package in mm in mm lb kg 2 1/2 63 (Close) 2 3/4 70 1.57 39.9 8 84 38.1 12 1/2 63 3 76 1.57 39.9 8 100 45.4 1 2 1/2 63 3 1/2 89 1.57 39.9 8 120 54.4 1 2 1/2 63 4 102 1.57 39.9 8 150 68.0 12 1/2 63 5 127 1.57 39.9 8 197 89.4 1 2 1/2 63 6 152 1.57 39.9 8 240 108.9 1 2 1/2 63 8 203 1.57 39.9 8 329 149.2 1 2 1/2 63 10 254 1.57 39.9 8 422 191.4 1 2 1/2 63 12 305 1.57 39.9 8 505 229.1 1 3 78 (Close) 2 5/8 67 1.63 41.4 8 118 53.5 1 3 78 3 76 1.63 41.4 8 130 59.0 1 3 78 3 1/2 89 1.63 41.4 8 157 71.2 137841021.63 41.4 8 200 90.7 1 3 78 5 127 1.63 41.4 8 260 117.9 1 3 78 6 152 1.63 41.4 8 300 136.1 137882031.63 41.4 8 411 186.4 1 3 78 10 254 1.63 41.4 8 528 239.5 1 3 78 12 305 1.63 41.4 8 630 285.8 1 3 1/2 91 (Close) 2 3/4 70 1.68 42.7 8 160 72.6 1 3 1/2 91 4 102 1.68 42.7 8 240 108.9 1 3 1/2 91 5 127 1.68 42.7 8 320 145.2 1 3 1/2 91 6 152 1.68 42.7 8 373 169.2 1 3 1/2 91 8 203 1.68 42.7 8 510 231.3 1 3 1/2 91 10 254 1.68 42.7 8 655 297.1 1 3 1/2 91 12 305 1.68 42.7 8 785 356.1 1 4 103 (Close) 2 7/8 73 1.73 43.9 8 180 81.6 1410341021.73 43.9 8 285 129.3 1 4 103 5 127 1.73 43.9 8 380 172.4 1 4 103 6 152 1.73 43.9 8 440 199.6 1410382031.73 43.9 8 600 272.2 1 4 103 10 254 1.73 43.9 8 775 351.5 1 4 103 12 305 1.73 43.9 8 925 419.6 1 5 129 (Close) 3 76 1.84 46.7 8 240 108.9 1 5 129 5 127 1.84 46.7 8 480 217.7 1 5 129 6 152 1.84 46.7 8 600 272.2 1 5 129 8 203 1.84 46.7 8 825 374.2 1 5 129 10 254 1.84 46.7 8 1055 478.5 15129123051.84 46.7 8 1260 571.5 1 6 155 (Close) 3 1/8 79 1.95 49.5 8 350 158.8 1 6 155 5 127 1.95 49.5 8 660 299.4 1615561521.95 49.5 8 820 372.0 1 6 155 8 203 1.95 49.5 8 1125 510.3 1 6 155 10 254 1.95 49.5 8 1440 653.2 16155123051.95 49.5 8 1720 780.2 1 GRC Nipples & Couplings A = Diameter B = Length Galvanized Rigid Conduit (GRC) Nipples (continued) Listed to UL Safety Standard 6 Manufactured in accordance with ANSI C80.1 B A Alflex® - Type RWA (Reduced Wall Aluminum Flexible Metal Conduit) Aluminum Flexible Metal Conduit. High Strength Aluminum Alloy Strip. 5/16" is UL Recognized Component. UL Listed in sizes 3/8" to 3". 600 Volt APPLICATIONS Alflex Type RWA (Reduced Wall Aluminum) Flexible Metal Conduit is suitable for the following installations: •Environmental air-handling spaces per 2011 National Electrical Code (NEC) 300.22(C) •Power and lighting branch circuit conductors and cables for connecting receptacles, luminaires, equipment, office partitions, etc. •Metal raceway for wires and cables per NEC (ANSI/NFPA-70) Article 348 •Motor feeder, branch, and control circuit conductors and cables •Class 1, Class 2, Class 3 Remote-control, signaling, and power-limited circuit conductors and cables •Fire alarm system conductors and cables of power-limited or non-power-limited fire alarm circuits •Voice, data, communications and video cables including CATV and optical fiber cables •Concealed or exposed installations per NEC Article 348 and the applicable NEC provisions •Elevators, hoistways, and escalators per NEC 620.21 •As a grounding conductor for lengths up to 6 feet (20A max) as per 2011 NEC 250.118(5) •Electric signs and outline lighting per NEC 600.7, 600.31 (1000 volts or less), and 600.32 (>1000 volts) •Hazardous location, Class 1, Div. 2, for flexible connectors only per 2011 NEC 501.10(B)(2) & 501.30(B) •UL 1, 2, & 3 Hour Through-Penetration Firestop Sytems: C-AJ-1462, C-AJ-1463, C-AJ-1464, W-L-1308, and W-L-1309 STANDARDS & REFERENCES •UL Listed per UL 1, Standard for Safety for Flexible Metal Conduit, ANSI/UL-1 •Meets federal specification WW-C-566c •NEC Type Designation - Article 348, Type FMC (flexible metal conduit) CONSTRUCTION Alflex Type RWA is manufactured with a lightweight, high strength aluminum alloy. Metal strip is helically formed into continuously interlocked flexible metal conduit that can withstand impact and crushing forces. Alflex™ is a trademark of Southwire Company. Trade Size (Inches) Approximate Weight (lbs/100 ft) Inner Diameter Min./Max. (inches) Outer Diameter Min./Max. (inches) Minimum* Bending Radius (Inches) Standard Coil Length (feet) Standard Reel Length (feet) 5/16*5.5 0.312 / -.0470 / 0.510 3.5 100 1000 3/8 7 0.375 / 0.393 .0560 / 0.610 4 100 / 250 1000 1/2 9 0.625 / 0.645 0.860 / 0.920 4 100 500 / 1000 3/4 12.5 0.812 / 0.835 1.045 / 1.105 5 100 500 / 1000 1 25 1.000 / 1.040 1.300 / 1.380 6 50 400 1-1/4 32 1.250 / 1.300 1.550 / 1.630 8 50 250 1-1/2 46 1.500 / 1.575 1.850 / 1.950 10 25 150 2 70 2.000 / 2.080 2.350 / 2.450 12 25 100 2-1/2 92 2.500 / -2.860 / 3.060 15 25 - 3 107 3.000 / -3.360 / 3.560 18 25 - 3-1/2**125 3.500 / -3.860 / 4.060 21 25 - 4**142 4.000 / -4.360 / 4.560 24 25 - * Trade size 5/16" is provided as UL Recognized construction. ** Trade sizes 3-1/2" and 4" are non-UL. Minimum bend radius based on NEC Chapter 9, Table 2 (other bends). FEATURES •Provides mechanical protection for conductors and cable •For use with listed connectors intended for NEC Type FMC (Flexible Metal Conduit) •66% lighter than steel •Cuts 80% faster than steel •Smooth interior for easy wire pulling •High strength aluminum alloy construction •Superior corrion resistance •Built in flexibility for simplified positioning ADDITIONAL APPLICATIONS •Listed wired fixtures per NEC 410.77(C) •Raised floors for connection of information technology per NEC 645.5(D)(2) and 645.5(D) •Places of assembly and theaters per NEC Articles 518 and 520 •Cranes & hoists per NEC 610.11(C) ONLINE CERTIFICATIONS AND TOOLS •UL Online Certifications Directory ( www.ul.com ) •CSA Online Certifications Directory ( www.csa.ca ) •UL Guide Information - Flexible Metal Conduit (DXUZ) •CSA Product Information - Flexible Metal Conduit (1811-01) Alflex - Type RWA www.afcweb.com LIQUID-TUFF™– UL Liquidtight Flexible Steel Conduit, Type LFMC (Grey, Black, Red, Orange, Yellow, Green) Description • UL bonded strip 3/8" – 11⁄4" for grounding • UL Liquidtight all sizes • Sunlight resistant • Flame retardant PVC jacket • Hot dipped zinc galvanized low carbon steel core • Available in Grey, Black, Red, Orange, Yellow or Green Temperature Rating • 80°C/176°F to -30°C/-22°F Dry • 60°C/140°F Wet • 70°C/158°F Oil resistant Applications • 600 volt and lower circuits • Direct burial in earth • Concrete embedment • Sunlight and weather exposure • Suitable for grounding per NEC®250.118(6), 3/8" – 11⁄4" • Hazardous location per NEC®501.10(B)(2)(4), 502.10(A)(2)(3), 502.10(B)(1)(1), 502.10(B)(2), 503.10(A)(3)(3), 503.10(B), 504.20 • Raised computer room floors per NEC®645.5(E)(2) • Service entrance wiring up to 6 feet per NEC®230.43(15) • Feeders and services for marina and boat yards References & Ratings • UL 360, File Reference E26540, CSA Certified File LL51593, CSA C22.2 Number 56 • NEC®250, 350, 390, 501.10(B)(2)(3), 502.10(A)(2)(2), 502.10(B)(2)(2) 503.10(A)(3)(2), 503.10(B), 504.20, 553.7(B), 600.31(A), 600.32(A)(1), 610.11(C), 620.21 (A)(1)(c)(2), 620.21(A)(2)(a), 620.21(A)(2)(d)(2), 620.21(A)(3)(a), 620.21(A)(3)(a), 620.21(A)(4)(2), 620.21(B)(1), 620.21(C)(1), 645.5(E)(2), 680.42(A)(1), 682.13, 690.31(A), 695.6(D) and 695.14(E) • Canadian Electrical Code (CEC) Part I Clause 12-1300 • UL approved for use in direct burial applications including concrete and earth burial (Sizes 3/8" through 4") • Conduit in sizes 11⁄2" and larger requires grounding conductor per NEC®350.60 • May be installed under raised computer room floors per NEC®645.5(E)(2) • Made in USA of US and/or imported materials Ordering Information Product Dimensions/Bend Radius Approx.Internal Product Trade Trade Coil Reel Weight/Diameter Bend Code Size Size Length Length 100 feet Over Jacket (min/max) Radius Black (inches) (mm) (feet) (feet) (pounds)(min/max)inches (inches) 6201-30-BK 3/8 12 100'—24 0.690/0.710 0.484/0.504 2 6202-30-BK 1/2 16 100'—31 0.820/0.840 0.622/0.642 3.25 6202-45-BK 1/2 16 —500'31 0.820/0.840 0.622/0.642 3.25 6202-60-BK 1/2 16 —1000'31 0.820/0.840 0.622/0.642 3.25 6203-30-BK 3/4 21 100'—49 1.030/1.050 0.820/0.840 4.25 6203-45-BK 3/4 21 —500'49 1.030/1.050 0.820/0.840 4.25 6203-60-BK 3/4 21 —1000'49 1.030/1.050 0.820/0.840 4.25 6204-30-BK 1 27 100'—79 1.290/1.315 1.041/1.066 6.5 6204-80-BK 1 27 —400'79 1.290/1.315 1.041/1.066 6.5 6205-24-BK 1 1⁄4 35 50'—103 1.630/1.660 1.380/1.410 8 6205-40-BK 1 1⁄4 35 —200'103 1.630/1.660 1.380/1.410 8 ´6206-24-BK 1 1⁄2 41 50'—109 1.865/1.900 1.575/1.600 9 ´6206-35-BK 1 1⁄2 41 —150'109 1.865/1.900 1.575/1.600 9 ´6207-30-BK 2 53 —100'146 2.340/2.375 2.020/2.045 11.12 External Diameter (inches) NOTE: All dimensions and weights are subject to normal manufacturing tolerances. Review NEC®350.60 and 250.118(6) for grounding requirements, conduit sizes 11⁄2" and larger. ´Minimum order quantity required. For more colors and sizes see the next page. 22 Liquid-Tuff™– Flexible Liquidtight Conduit Commercial NOTE: • All dimensions and weights are subject to normal manufacturing tolerances. • Made in USA of US and/or imported materials Review NEC®350.60 and 250.118(6) for grounding requirements. *3⁄4” available on 1000’ Reels, call for details 1923www.afcweb.com Liquid-Tuff™– Flexible Liquidtight Conduit Commercial LIQUID-TUFF™– UL Liquidtight Flexible Steel Conduit, Type LFMC (Grey, Black, Red, Orange, Yellow, Green) Ordering Information Product Dimensions/Bend Radius Approx.Internal Product Trade Trade Coil Reel Weight/Diameter Bend Code Size Size Length Length 100 feet Over Conduit Over Jacket (min/max) Radius Gray (inches) (mm) (feet) (feet) (pounds) (min/max) (min/max) inches (inches) 6201-30-00 3/8 12 100'—24 0.594/0.614 0.690/0.710 0.484/0.504 2 6201-45-00 3/8 12 —500'24 0.594/0.614 0.690/0.710 0.484/0.504 2 6201-60-00 3/8 12 —1000'24 0.594/0.614 0.690/0.710 0.484/0.504 2 6201-65-00 3/8 12 —2500'24 0.594/0.614 0.690/0.710 0.484/0.504 2 6202-30-00 1/2 16 100'—31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-45-00 1/2 16 —500'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-60-00 1/2 16 —1000'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-68-00 1/2 16 —3500'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6203-30-00 3/4 21 100'—49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-45-00 3/4 21 —500'49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-60-00 3/4 21 —1000'49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-66-00 3/4 21 —2000'49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6204-30-00 1 27 100'—79 1.201/1.226 1.290/1.315 1.041/1.066 6.5 6204-41-00 1 27 —400'79 1.201/1.226 1.290/1.315 1.041/1.066 6.5 6204-64-00 1 27 —1250'79 1.201/1.226 1.290/1.315 1.041/1.066 6.5 6205-24-00 1 1⁄4 35 50'—103 1.540/1.570 1.630/1.660 1.380/1.410 8 6205-40-00 1 1⁄4 35 —200'103 1.540/1.570 1.630/1.660 1.380/1.410 8 6205-47-00 1 1⁄4 35 —750'103 1.540/1.570 1.630/1.660 1.380/1.410 8 6206-24-00 1 1⁄2 41 50'—109 1.735/1.770 1.865/1.900 1.575/1.600 9 6206-35-00 1 1⁄2 41 —150'109 1.735/1.770 1.865/1.900 1.575/1.600 9 6206-62-00 1 1⁄2 41 —600'109 1.735/1.770 1.865/1.900 1.575/1.600 9 6207-24-00 2 53 50'—146 2.180/2.215 2.340/2.375 2.020/2.045 11.12 6207-30-00 2 53 —100'146 2.180/2.215 2.340/2.375 2.020/2.045 11.12 6207-80-00 2 53 —300'146 2.180/2.215 2.340/2.375 2.020/2.045 11.12 6208-22-00 2 1⁄2 63 25'—169 2.640/2.675 2.840/2.875 2.480/2.505 14.62 6208-79-00 2 1⁄2 63 —275'169 2.640/2.675 2.840/2.875 2.480/2.505 14.62 6209-22-00 3 78 25'—195 3.295/3.335 3.460/3.500 3.070/3.100 17.5 6209-56-00 3 78 —175'195 3.295/3.335 3.460/3.500 3.070/3.100 17.5 6220-22-00 3 1⁄2 91 25'—230 3.720/3.789 3.960/4.000 3.500/3.540 20 6220-56-00 3 1⁄2 91 —175'230 3.720/3.789 3.960/4.000 3.500/3.540 20 6210-22-00 4 103 25'—250 4.220/4.280 4.460/4.500 4.000/4.040 24 6210-30-00 4 103 —100'250 4.220/4.280 4.460/4.500 4.000/4.040 24 RED* 6202-30-RD 1/2 16 100'—31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-60-RD 1/2 16 —1000'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6203-30-RD 3/4 21 100'—49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-45-RD 3/4 21 —500' *49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 ORANGE* 6202-30-OE 1/2 16 100'—31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-60-OE 1/2 16 —1000'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6203-30-OE 3/4 21 100'—49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-45-OE 3/4 21 —500' *49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 YELLOW* 6202-30-YW 1/2 16 100'—31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-60-YW 1/2 16 —1000'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6203-30-YW 3/4 21 100'—49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-45-YW 3/4 21 —500' *49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 GREEN* 6202-30-GN 1/2 16 100'—31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6202-60-GN 1/2 16 —1000'31 0.732/0.765 0.820/0.840 0.622/0.642 3.25 6203-30-GN 3/4 21 100'—49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 6203-45-GN 3/4 21 500' *49 0.930/0.960 1.030/1.050 0.820/0.840 4.25 External Diameter (inches) www.afcweb.com Liquid-Tuff™– Flexible Liquidtight Conduit Commercial LIQUID-TUFF™ UL Liquidtight Flexible Steel Conduit, Type LFMC Scope This specification covers AFC Cable Systems, Inc. UL LIQUID-TUFF™ Liquidtight Flexible Steel Conduit designed for use as a raceway for power, control and communication cables in accordance with Article 350 of the National Electrical Code. The product is Underwriters Laboratories Inc. (UL) Listed for 80°C (176°F) in a dry location, 60°C (140°F) in a wet location and 70°C (158°F) in an oily location. It is also UL Listed in all trade sizes for direct burial in either earth or concrete encasement, outdoor use and sunlight resistance. This LIQUID-TUFF®is now UL Listed for 70°C OIL RESISTANT applications. In addition the product is CSA certified for use at 75°C (167°F) in dry and oily locations and for minus 25°C (-13°F) low temperature applications. This Liquidtight Flexible Steel Conduit is manufactured and tested in accordance with Underwriters Laboratories Inc. Standard UL 360 and CSA International Standard CSA C22.2 Number 56. The product carries the UL Listing Mark and the CSA Certification Mark. Construction The Type UL Liquidtight Flexible Steel Conduit shall be formed from a zinc coated galvanized low carbon steel strip having a uniform width and thickness. The construction shall be in accordance with UL 360 and CSA C22.2 Number 56 requirements. The finished Type LFMC dimensions shall be in accordance with Table 5.1 of UL 360 and Table 2 of CSA C22.2 No. 56 which are summarized in Table 3. Jacket – PVC A rugged moisture, oil and sunlight resistant polyvinyl chloride (PVC) jacket shall be applied directly over the flexible metal conduit with a wall thickness in accordance with Table 4.1 of UL 360 and Table 4 of CSA C22.2 No.56 which are summarized in Table 2. Jacket Color: Gray, Black, Red, Orange, Yellow, or Green Grounding Permanent circuit ground protection is provided through the continuous bonding strip built into the conduit core in sizes 3/8" through 11⁄4". A separate grounding conductor is required by the NEC®for trade sizes 11⁄2" and larger. The Canadian Electric Code requires a grounding conductor for all trade sizes of Liquidtight Flexible Metal Conduit. Reference Standards UL 360 Standard for Liquidtight Flexible Steel Conduit CSA C22.2 No. 56 Standard for Flexible Metal Conduit and Liquidtight Flexible Metal Conduit File Reference(s): UL E26540; CSA 51593 NEC®Articles: NEC ®250.118(6), 350.60, 390.15, 501.10(B)(2), 502.10(A)(2), 503.10(A)(2), 511.7(A)(1), 645.5(D)(2), 680.21, 680.42, 695.6(E) and 695.14(E) Department of Defense Adopted UL 360 on October 1, 1987 Markings The surface of the outer jacket shall be clearly marked with a legible print legend in compliance with UL 360, and CSA C22.2 No. 56. Performance Tests In accordance with UL 360 and CSA C22.2 No. 56, the completed UL LIQUID-TUFF™Liquidtight Flexible Steel Conduit shall meet all of the performance requirements outlined in Appendix A. LIQUID-TUFF™ LFMC- UL 24 For more information, call 800.257.8182 or visit wheatland.com Tested and Certified for Safety FasTrak Plus EMT is CSA Certified to CSA C22.2 No. 83.1-07 or UL® Listed to UL 797, depending on the market being supplied. It is manufactured in accordance with ANSI® C80.3, UL 797 and federal specifications WW-C-563. It provides mechanical protection for cables and conductors, reduces electromagnetic field exposure, shields against electromagnetic interference and is recognized as an equipment grounding conductor by NFPA 70: NEC 250.118 (4). Email info@wheatland.com for a copy of Georgia Tech’s Grounding and ElectroMagnetic Interference (GEMI) Analysis software. Designed for Quality and Efficiency At Wheatland Tube, we leverage our experience and the latest technologies to provide a consistent quality product with on-time deliveries. We manufacture FasTrak Plus EMT from mild steel strip in state-of-the-art ERW mills with the industry’s leading in-line galvanizing process that applies molten zinc to the outside diameter. A clear coating is then applied to the outside diameter to inhibit rust and reduce storage stains. The inside diameter is sprayed with a proprietary coating for corrosion resistance and easy wire pulling. Product is then inspected visually and with instruments to ensure all meet the product standard specifications. Our complete in-house production capabilities and quality control programs provide consistency in production. Green and Sustainable FasTrak Plus EMT contains recycled steel content of various amounts, depending on the steel manufacturing process, and will provide decades of reliable service if properly maintained. Conductors may be easily removed and new conductors or cables inserted. Future circuits may be added in the same conduit, as permitted by the code. At the end of its life, the steel may be fully recycled. 5' lengths — trade sizes ½ and ¾ Accurate circular cross section with uniform wall thickness Interior surface free from defects injurious to conductors Lightweight, easy to install Galvanized OD with additional clear coating Proprietary ID coating for fast wire- pulling performance Contains recycled steel An easy but tough wiring solution With enhanced ID coating, FasTrak Plus EMT offers exceptional wire-pulling performance. A lightweight, smooth-pull wiring solution, easy to bend, yet tough enough for all locations that comply with the National Electric Code® (NEC®), including dry, wet, exposed, concealed or hazardous locations. FasTrakTM Plus Electrical Metallic Tubing (EMT): Also available in 20' * The quantity per lift conforms to the National Electrical Manufacturers Association Standards Publication RN-2, Packaging of Master Bundles for Steel Rigid Conduit, Intermediate Metal Conduit (IMC) and Electrical Metallic Tubing (EMT). Pack quantities for Canadian distribution does not comply with NEMA RN-2. TRADE SIZE METRIC DESIGNATOR BUNDLE TAPECOLOR QUANTITy /  BUNDLE QUANTITy / LIFT*WEIGHT / LIFT VOLUME / LIFT ft.m Pieces Bundles ft.m lbs.kg cu. ft.cu. m 1/2 16 Black 100 30.5 —70 7000 2134 2100 952.5 31.7 0.9 3/4 21 Red 100 30.5 —50 5000 1524 2300 1043.3 36.1 1.0 1 27 Blue 100 30.5 —30 3000 914 2010 911.7 36.5 1.0 1 1/4 35 Red 50 15.2 —40 2000 610 2020 916.3 38.2 1.1 1 1/2 41 Black 50 15.2 —30 1500 457 1740 789.3 37.9 1.1 2 53 ———120 —1200 366 1776 805.6 46.7 1.3 2 1/2 63 ———61 —610 186 1318 597.8 41.5 1.2 3 78 ———51 —510 155 1341 608.3 48.9 1.4 3 1/2 91 ———37 —370 113 1291 585.6 48.6 1.4 4 103 ———30 —300 91 1179 534.8 50.0 1.4 PACkAGING (10' LENGTHS) * 5' lengths of EMT are available in trade sizes ½" — 4". ** For information only, not a UL 797 requirement. Applicable tolerances: Length: 10' (3.05 m) ± ¼" (± 6 mm), Outside diameter: ½ through 2: ± 0.005" (16 through 53: ± 0.13 mm), 2 ½: ± 0.010" (63: ± 0.25 mm), 3: ± 0.015" (78: ± 0.38 mm), 3 ½ and 4: ± 0.020" (91 and 103: ± 0.5 mm) TRADE SIZE METRIC DESIGNATOR WEIGHT PER 100 FT.OUTSIDE DIAMETER INSIDE DIAMETER**WALL THICkNESS** lbs.kg in.mm in.mm in.mm 1/2 16 30 13.6 0.706 17.93 0.622 15.80 0.042 1.07 3/4 21 46 20.9 0.922 23.42 0.824 20.93 0.049 1.24 1 27 67 30.4 1.163 29.54 1.049 26.64 0.057 1.45 1 1/4 35 101 45.8 1.510 38.35 1.380 35.05 0.065 1.65 1 1/2 41 116 52.6 1.740 44.20 1.610 40.89 0.065 1.65 2 53 148 67.1 2.197 55.80 2.067 52.50 0.065 1.65 2 1/2 63 216 98.0 2.875 73.03 2.731 69.37 0.072 1.83 3 78 263 119.3 3.500 88.90 3.356 85.24 0.072 1.83 3 1/2 91 349 158.3 4.000 101.60 3.834 97.38 0.083 2.11 4 103 393 178.3 4.500 114.30 4.334 110.08 0.083 2.11 EMT WEIGHTS AND DIMENSIONS (10' LENGTHS*) TRADE SIZE METRIC DESIGNATOR QUANTITy / LIFT*WEIGHT / LIFT VOLUME / LIFT Pieces ft.m lbs.kg cu. ft.cu. m 1/2 16 175 3500 1066.8 1045 474 12.1 0.34 3/4 21 125 2500 762 1144 518.9 14.8 0.42 1 27 75 1500 457.2 1010 458.1 14.1 0.40 1 1/4 35 50 1000 304.8 1005 455.9 15.8 0.45 1 1/2 41 37 740 225.6 858 389.4 15.6 0.44 2 53 37 740 225.6 1098 497.9 24.8 0.70 2 1/2 63 19 380 115.8 822 373 21.8 0.62 3 78 19 380 115.8 998 452.9 32.3 0.92 3 1/2 91 19 380 115.8 1325 600.9 42.2 1.20 4 103 10 200 61 787 356.8 28.1 0.80 * The quantity per lift conforms to the National Electrical Manufacturers Association Standards Publication RN-2, Packaging of Master Bundles for Steel Rigid Conduit, Intermediate Metal Conduit (IMC) and Electrical Metallic Tubing (EMT). Pack quantities for Canadian distribution does not comply with NEMA RN-2. PACkAGING (20' LENGTHS) LISTEDNO. E48675 STEEL EMT Also available in 20' Project Information Company Name: Address: City: State & Zip: Phone: Project Name: City: State:www.alliedeg.com E-Z Pull® EMT • Hot galvanized steel using patented inline Flo-Coat® process for long lasting exterior protection • E-Z Pull interior coating provides a smooth raceway for fast, easier wire-pulling • Excellent mechanical protection for conductors • Ductility for faster and easier bending • Optimal EMI shielding characteristics • Listed to Underwriters Laboratories Safety Standard UL 797 • Manufactured in accordance with ANSI C80.3 • Available in sizes 1/2 (16) - 4 (103) True Color™ EMT • All the benefits of E-Z Pull EMT • Instant identification of multiple circuits • Fire Alarm® Red EMT • Healthcare Green EMT • Data Com Blue EMT • Available in 8 colors • Available in sizes 1/2 (16) - 4 (103) Electrical Metallic Tubing (EMT) and True Color™ EMT Black EMT • Blends in dark colored areas Fire Alarm® EMT • Emergency circuits • Fire alarm and Security systems Orange EMT • Construction/research areas • Fiber optic systems • Auto repair/maintenance Yellow EMT • High voltage wiring • Caution areas • Special equipment Green EMT • Hospital and healthcare areas • Nurse call stations • Critical circuits Blue EMT • Low voltage wiring • Data com/video • Network security Purple EMT • Specialty wiring systems • Security systems White EMT • Blends in light colored areas Silver EMT • Standard Use • Contemporary architecture Quality Electrical Metallic Tubing Identify Important Circuits Instantly! True Color™ Applications NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Manufactured for Long Life Allied Tube & Conduit® EMT is precision manufactured from high grade mild strip steel for exceptional durability and long-lasting life. Allied EMT is hot galvanized using a patented inline Flo-Coat® process. This process combines zinc, a conversion coating, and a clear organic polymer topcoat to form a triple layer of protection against corrosion and abrasion. E-Z Pull® EMT combines strength with ductility, providing easy bending, cutting and joining while resisting flattening, kinking and splitting. Available in sizes 1/2 (16) - 4 (103). Coatings Allied’s EMT (Electrical Metallic Tubing) has a special low friction ID coating called E-Z Pull that greatly improves the slip properties between conduit and wire. With E-Z Pull EMT, wire pulls through the EMT smoothly and easily, making installation easier and faster. EMI Shielding Allied EMT is very effective in reducing electromagnetic field levels for encased power distribution circuits, shielding computers and other sensitive electronic equipment from the effects of electromagnetic interference. For more information on EMT shielding, visit www.alliedeg.com to obtain the GEMI (Grounding and Electro- Magnetic Interference) software analysis program. Codes & Standards Compliance Allied EMT is listed to Underwriters Laboratories Safety Standard UL 797 and meets ANSI C80.3. These standards have been adopted as federal specifications in lieu of WWC 563. EMT is recognized as an equipment grounding conductor by NEC Section 250-118. Documentation for compliance with NEC Article 250 is also available in the GEMI (Grounding and Electro-Magnetic Interference) analysis software and related research studies found at the www.alliedeg.com website. Installation of EMT shall be in accordance with the National Electrical Code and the UL listing information. Allied EMT is listed in category FJMX. Master bundles conform to NEMA Standard RN2. Specification Data To specify Allied EMT, include the following: Electrical Metallic Tubing shall be equal to that manufactured by Allied Tube & Conduit Corporation. EMT shall be hot galvanized steel O.D. with an organic corrosion resistant I.D. coating, and shall be listed to UL Safety Standard 797 and manufactured in accordance with ANSI C80.3. Electrical Metallic Tubing (EMT) and True Color™ EMT in mm in mm lb kg ft m ft m 1/2 16 0.706 17.93 0.042 1.07 30 13.6 7000 2135 3500 1066.8 3/4 21 0.922 23.42 0.049 1.24 46 20.9 5000 1525 2500 762.0 1 27 1.163 29.54 0.057 1.45 67 30.4 3000 915 1500* 457.2 1-1/4 35 1.510 38.35 0.065 1.65 101 45.8 2000 610 2000 609.6 1-1/2 41 1.740 44.20 0.065 1.65 116 52.6 1500 457.5 1500 457.2 2 53 2.197 55.80 0.065 1.65 148 67.1 1200 366.0 1200 365.7 2-1/2 63 2.875 73.03 0.072 1.83 216 98.0 610 186.1 610 185.9 3 78 3.500 88.90 0.072 1.83 263 119.3 510 155.6 510 155.4 3-1/2 91 4.000 101.60 0.083 2.11 349 158.3 370 112.9 370 112.7 4 103 4.500 114.30 0.083 2.11 393 178.3 300 91.5 300 91.5 1Outside diameter tolerances: +/- .005 in. (.13mm) for trade sizes 1/2 (16mm) through 2 (53mm); +/- .010 in. (.25mm) for trade sizes 2-1/2 (63mm); +/- .015 in. (.38mm) for trade size 3 (78mm); +/- .020 in. (.51mm) for trade sizes 3-1/2 (91mm) and 4 (103mm). FEATURES & SPECIFICATIONS *Blue trade size 1 master bundle size: 3000 ft / 915 m ** Other Color Trade Sizes 2 - 4 are available thru special order NOTE: Length = 10 ft. (3.05m) with a tolerance of +/- .25 in. (6.35 mm) Trade Size Metric Designator Approximate Weight Per 100 Ft. (30.5M) Outside Diameter1 Nominal Wall Thickness2 Red and Galvanized Master Bundle Quantity True Color** Bundle Qty. Electrical Metallic Tubing (EMT) and True Color™ EMT Listed to Underwriters Laboratories Safety Standard UL 797 Manufactured in accordance with ANSI C80.3 NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Electrical Metallic Tubing (EMT) Elbows Trade Size Metric Designator Radius (A)1 Offset (B)2 Straight (D)1 Approximate Weight Per 100 Pieces Standard Package in mm in mm in mm lb kg 1/2 16 4 102 5 7/8 149 1 1/2 38 25 11.3 25 3/4 21 4 1/2 114 7 178 1 1/2 38 46 20.9 50 1 27 5 3/4 146 8 3/4 222 1 7/8 48 84 38.1 25 1 1/4 35 7 1/4 184 10 1/8 257 2 51 144 65.3 20 1 1/2 41 8 1/4 210 11 3/4 298 2 51 193 87.5 15 2 53 9 1/2 241 14 356 2 51 296 134.3 10 2 1/2 63 10 1/2 267 16 1/4 413 3 76 504 228.6 1 3 78 13 330 18 3/4 476 3 1/8 79 701 318.0 1 3 1/2 91 15 381 21 1/4 540 3 1/4 83 1047 474.9 1 4 103 16 406 23 3/8 594 3 3/8 86 1310 594.2 1 EMT 90° Elbows Listed to Underwriters Laboratories Safety Standard UL 797 Manufactured in accordance with ANSI C80.3 Trade Size Metric Designator Radius (A)1 Offset (B)2 Offset (C)2 Straight (D)1 Approximate Weight Per 100 Pieces Standard Package in mm in mm in mm in mm lb kg 1/2 16 4 102 6 1/8 156 2 1/2 64 1 1/2 38 18 8.2 25 3/4 21 4 1/2 114 7 3/8 187 3 1/8 79 1 1/2 38 33 15.0 50 1 27 5 3/4 146 8 3/4 222 3 5/8 92 1 7/8 48 56 25.4 25 1 1/4 35 7 1/4 184 10 1/8 257 4 1/8 105 2 51 97 44.0 20 1 1/2 41 8 1/4 210 13 1/8 333 5 3/8 137 2 51 145 65.8 15 2 53 9 1/2 241 13 1/8 333 5 1/2 140 2 51 185 83.9 10 2 1/2 63 10 1/2 267 17 1/2 445 7 1/4 184 3 76 360 163.3 1 3 78 13 330 17 1/2 445 7 1/4 184 3 1/8 79 438 198.7 1 3 1/2 91 15 381 26 1/8 664 10 7/8 276 3 1/4 83 873 396.0 1 4 103 16 406 26 1/4 667 10 7/8 276 3 3/8 86 983 445.9 1 EMT 45° Elbows Listed to Underwriters Laboratories Safety Standard UL 797 Manufactured in accordance with ANSI C80.3 1Minimum requirement as per UL Standard 2Dimensions and weights are approximate Sizes 2-1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) 1Minimum requirement as per UL Standard 2Dimensions and weights are approximate Sizes 2-1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (90°, 60°, 30°, 22-1/2°, 15° & 11-1/4°) 15 30 45 60 90 22.5EMT Elbow - Dimensions A = RadiusB = OsetC = Straight 15 30 45 60 90 22.5 EMT Elbow - Dimensions A = Radius B = Oset C = Straight B C A D D B B D A D NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Trade Size Metric Designator Radius (A)Offset (B)2 Straight (D)2 Approximate Weight Per 100 Pieces in mm in mm in mm lb kg 1 27 12 305 20 5/8 524 8 5/8 219 201 91.2 1 27 15 381 24 1/4 616 9 1/4 235 235 106.6 1 27 18 457 27 7/8 708 9 7/8 251 268 121.6 1 27 24 610 34 5/8 879 10 5/8 270 329 149.2 1 27 30 762 41 1041 11 279 385 174.6 1 27 36 914 46 3/4 1187 10 3/4 273 436 197.8 1 27 42 1067 54 1372 12 305 503 228.2 1 27 48 1219 60 1/4 1530 12 1/4 311 558 253.1 1 1/4 35 12 305 20 5/8 524 8 5/8 219 303 137.4 1 1/4 35 15 381 24 1/4 616 9 1/4 235 354 160.6 1 1/4 35 18 457 27 7/8 708 9 7/8 251 404 183.3 1 1/4 35 24 610 34 5/8 879 10 5/8 270 497 225.4 1 1/4 35 30 762 41 1041 11 279 581 263.5 1 1/4 35 36 914 46 3/4 1187 10 3/4 273 657 298.0 1 1/4 35 42 1067 54 1372 12 305 758 343.8 1 1/4 35 48 1219 60 1/4 1530 12 1/4 311 842 381.9 1 1/2 41 15 381 24 1/4 616 9 1/4 235 406 184.2 1 1/2 41 18 457 27 7/8 708 9 7/8 251 464 210.5 1 1/2 41 24 610 34 5/8 879 10 5/8 270 570 258.6 1 1/2 41 30 762 41 1041 11 279 667 302.6 1 1/2 41 36 914 46 3/4 1187 10 3/4 273 754 342.0 1 1/2 41 42 1067 54 1372 12 305 870 394.6 1 1/2 41 48 1219 60 1/4 1530 12 1/4 311 967 438.6 2 53 15 381 24 1/4 616 9 1/4 235 518 235.0 2 53 18 457 27 7/8 708 9 7/8 251 592 268.5 2 53 24 610 34 5/8 879 10 5/8 270 728 330.2 2 53 30 762 41 1041 11 279 851 386.0 2 53 36 914 46 3/4 1187 10 3/4 273 962 436.4 2 53 42 1067 54 1372 12 305 1110 503.5 2 53 48 1219 60 1/4 1530 12 1/4 311 1233 559.3 2 1/2 63 18 457 27 7/8 708 9 7/8 251 864 391.9 2 1/2 63 24 610 34 5/8 879 10 5/8 270 1062 481.7 2 1/2 63 30 762 41 1041 11 279 1242 563.4 2 1/2 63 36 914 46 3/4 1187 10 3/4 273 1404 636.9 2 1/2 63 42 1067 54 1372 12 305 1620 734.8 2 1/2 63 48 1219 60 1/4 1530 12 1/4 311 1800 816.5 EMT Large Radius 90° Elbows Listed to Underwriters Laboratories Safety Standard UL 797 Manufactured in accordance with ANSI C80.3 2For information only, not a requirement as per UL Standard Chart continued on the next page Sizes 2-1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) Electrical Metallic Tubing (EMT) Elbows 15 30 45 60 90 22.5EMT Elbow - Dimensions A = RadiusB = OsetC = Straight B B A D D NOTE: Special orders are non-cancelable, non-returnable and non-refundable www.alliedeg.com 16100 S. Lathrop Ave., Harvey, IL 60426 Phone / 708.339.1610 • Toll-Free / 800.882.5543 Trade Size Metric Designator Radius (A)Offset (B)2 Straight (D) 2 Approximate Weight Per 100 Pieces in mm in mm in mm lb kg 3 78 15 381 24 1/4 616 9 1/4 235 921 417.8 3 78 18 457 27 7/8 708 9 7/8 251 1052 477.2 3 78 24 610 34 5/8 879 10 5/8 270 1293 586.5 3 78 30 762 41 1041 11 279 1512 685.8 3 78 36 914 46 3/4 1187 10 3/4 273 1710 775.7 3 78 42 1067 54 1372 12 305 1973 895.0 3 78 48 1219 60 1/4 1530 12 1/4 311 2192 994.3 3 1/2 91 18 457 27 7/8 708 9 7/8 251 1396 633.2 3 1/2 91 24 610 34 5/8 879 10 5/8 270 1716 778.4 3 1/2 91 30 762 41 1041 11 279 2007 910.4 3 1/2 91 36 914 46 3/4 1187 10 3/4 273 2269 1029.2 3 1/2 91 42 1067 54 1372 12 305 2618 1187.5 3 1/2 91 48 1219 60 1/4 1530 12 1/4 311 2908 1319.1 4 103 24 610 34 5/8 879 10 5/8 270 1932 876.4 4 103 30 762 41 1041 11 279 2260 1025.1 4 103 36 914 46 3/4 1187 10 3/4 273 2555 1158.9 4 103 42 1067 54 1372 12 305 2948 1337.2 4 103 48 1219 60 1/4 1530 12 1/4 311 3275 1485.5 EMT Large Radius 90° Elbows (continued) Listed to Underwriters Laboratories Safety Standard UL 797 Manufactured in accordance with ANSI C80.3 2For information only, not a requirement as per UL Standard Sizes 2-1/2 (63) and larger shipped in palletized cartons or bulk. Also available in the following Degrees (60°, 45°, 30°, 22-1/2°, 15° & 11-1/4°) Electrical Metallic Tubing (EMT) Elbows 15 30 45 60 90 22.5EMT Elbow - Dimensions A = RadiusB = OsetC = Straight B B D D A 220 Cement Carlon®Cement Medium Bodied Clear PVC Solvent Cement with dauber Medium Bodied Gray PVC Solvent Cementwith dauber* All-Weather “Quick-Set” Clear Solvent Cement with dauber* All-Weather ENT Blue “Quick-Set” Solvent Cement with brush* Low VOC Gray PVC Solvent Cementwith dauber* Clear Primer with dauber Part Std.No. Size Ctn. Qty. VC9964 1/2 Pint 10 VC9963 Pint 24 VC9962 Quart 12 VC9961P Gallon 6 Part Std.No. Size Ctn.Qty. VC9924-24 1/2 Pint 24 VC9923 Pint 24 VC9922 Quart 12 VC9941P Gallon 6 Part Std.No. Size Ctn.Qty. VC9984 1/2 Pint 10 VC9983 Pint 24 VC9982 Quart 12 VC9981P Gallon 6 Part Std. No. Size Ctn. Qty. VC9992 Quart 12 *Meets ASTM D2564 *No daubers for gallon cans Recommended for all grades and types of Carlon PVC conduit, duct, wireway and fittings, except Flex-Plus ® Blue™ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. Recommended for all grades and types of Carlon PVC conduit,duct, wireway and fittings, except Flex- Plus®Blue™ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. Recommended for all grades and types of Carlon PVC conduit, duct, wireway and fittings, except Flex- Plus®Blue™ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. Recommended for all grades and types of Carlon PVC conduit,duct, wireway and fittings, except Flex- Plus®Blue™ENT (Electrical Nonmetallic Tubing.) Up through 6" diameter. VOC emission of 490 grams/liter per the Bay and South Coast test method. Required for use with Flex-Plus®Blue™ ENT (Electrical Nonmetallic Tubing), Riser-Gard®, P&C Flex ®, and Carlon PVC fittings. Up through 4" diameter. Recommended for use with Carlon cement and all types and sizes of Carlon WireSafe® wireway. Recommended pipe application and sizes 10˚-30˚F Not recommended 30˚-50˚F 5-6 minutes 50˚-70˚F 3-4 minutes 70˚-90˚F 1-2 minutes 10˚-30˚F Not recommended 30˚-50˚F 5-6 minutes 50˚-70˚F 3-4 minutes 70˚-90˚F 1-2 minutes 10˚-30˚F 4-5 minutes 30˚-50˚F 3-4 minutes 50˚-70˚F 1-2 minutes 70˚-90˚F 1/2-11/2 minutes 10˚-30˚F 4-5 minutes 30˚-50˚F 3-4 minutes 50˚-70˚F 1-2 minutes 70˚-90˚F 1/2-11/2 minutes 10˚-30˚F Not recommended 30˚-50˚F 5-6 minutes 50˚-70˚F 3-4 minutes 70˚-90˚F 1-2 minutes N/A 2 hrs.350 psi 16 hrs.800 psi 72 hrs.1,500 psi 2 hrs.350 psi 16 hrs.800 psi 72 hrs.1,500 psi 2 hrs.350 psi 16 hrs.800 psi 72 hrs.1,500 psi 2 hrs.350 psi 16 hrs.800 psi 72 hrs.1,500 psi 2 hrs.350 psi 16 hrs.800 psi 72 hrs.1,500 psi N/A Set-up time (Evaporation Rate) 5˚ to 100˚F N/A Lap Shear @ 73˚F Part Std.No. Size Ctn. Qty. VC9LV4 1/2 Pint 10 VC9LV3 Pint 24 VC9LV2 Quart 12 Recommended installation temperature 40˚ to 100˚F 40˚ to 100˚F -5˚ to 100˚F 4˚ to 100˚F 40˚ to 100˚F Viscosity at 75˚ as manufactured 500-900 cps 500-900 cps 400-700 cps 400-700 cps 500-900 cps (MSDS sheets available at www.carlon.com ) Part Std. No. Size Ctn. Qty. VC9903 Pint 24 VC9902 Quart 12 Purple: VC9932 Quart 12 Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com 221 Cement Average number of joints per can Pipe size 1/2 Pint Pint Quart Gallon 1/2 140 275 550 2,200 3/4 90 180 360 1,440 1 70 140 280 1,120 11/4 50 100 200 800 11/2 37 75 150 600 2 20 40 80 320 21/2 17 35 70 280 3 15 30 60 240 31/2 13 27 54 216 4 12 25 50 200 5 9 19 38 150 6 6 12 24 95 Average shelf-life of all Carlon cement is 24 months (unopened cans stored below 80˚F.) All Carlon cements are specially formulated to be used with Carlon PVC products, and do not require primers when parts are clean of dirt and moisture. Cementing PVC Conduit: 1.Make square saw cut with fine tooth saw. 2.Deburr and round inside edge of the cut end. 3.Clean socket ID and spigot OD of dirt and moisture. 4.Apply a uniform coat of cement to spigot end and push onto socket bottom, rotating 1/4 turn. 5.Allow time to set before disturbing. This will depend upon temperature. Cementing PVC Conduit for Submerged Areas Requiring Air or Water Tightness: 1.Follow the procedure to the left for cementing conduit. 2.Test workmanship by conducting a low pressure air (3.0 - 5.0 psi) test after system is installed and cemented joints are set. 3.Plug and block ends to prevent movement prior to pressurization. 4.Check for leaks with soap solution. 5.Even low pressure air can cause high thrust loads and caution must be observed. Cementing ENT for Concrete-Tight Applications: 1.Use Carlon Socket tight fittings or couplings. 2.Do not use chemical primer or cleaner. 3.Apply a light uniform coat of cement, labeled for use with ENT. 4.A brush shall be used to apply the cement. 5.Brush excess cement out of ENT grooves 6.Promptly insert ENT into fitting while cement is wet, until the fitting stop is reached,and give 1/4 turn. 7. Do not disturb until the joint is set. Cement Joints Carlon nonmetallic products are joined by means of solvent cement joints. Sizes 1/2" through 11/2" should be cut square (using a fine tooth handsaw) and deburred. For sizes 2" through 6" a miter box or similar saw guide should be utilized to keep the material steady.After cutting and deburring, wipe ends clean of dust, dirt and shavings. Joining process as follows: Be sure that conduit end is clean and dry.Apply coat of Carlon Solvent Cement (use dauber) to end of conduit, the length of the socket to be attached. Push conduit firmly into fitting while rotating conduit slightly about one-quarter turn to spread cement evenly.Allow joint to set approximately 10 minutes. Carlon recommends the use of Carlon cement for proper solvent cement joints. Since this cement is prepared particularly for our product compounds and tolerances,we cannot guarantee joints assembled with cement materials supplied by other manufacturers. Regular grade grey solvent cement will accommodate most application situations being of a general purpose nature. In situations requiring an extremely fast-setting joint,(low temperature or difficult installation conditions) Carlon All Weather Quick-Set Cement is recommended.Standard grade clear cement is recom- mended for noncritical utility applications where gap filling and leak testing are not required. Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com PRODUCT SEARCH SUPP DISTR HOME WHAT’S NEW SERVICE / SUPPORT WHERE TO BUY INSTRUCTION MANUALS CO Hand Tools Holemaking Bending Fishing Cable Pulling Wire & Cable Termination Voice Data Video Testing & Measurement Storage & Material Handling Hydraulic Pumps & Miscellaneous Name: Poly Line 5200' (1585 m) Cat #: 431 UPC #: 21482 Spec: Size 430 - 6500' (1981 m), 431 - 5200' (1585 m), 37959 - 2200' (670 m) Capacity 430 - 210 lbs. (934 N) average breaking strength 431-240 lbs. (1 kN) average breaking strength 37959 - 500 lbs. (2.2 kN) average breaking strength Weight 430 - 11 lbs. (5 kg), 431 - 12 lbs. (5.4 kg) Description: Ready-to-use, pre-punched hole in lid with resealable cap. Use with power fishing systems directly from the container. Resists tangling when dispensing. Rot and mildew resistant. Handy reusable plastic dispenser pail with handle keeps the line dry. Use to pull rope through conduit. © 2007 Greenlee Textron Inc., a subsidiary of Textron Inc. All rights reserved. Privacy Policy Terms of Use Careers Page 1 of 1Greenlee Products - Greenlee A Textron Company 8/18/2008http://www.mygreenlee.com/Products/main.shtml?p_search=431&greenlee_category_id=1... Cabinet Compound Bushings For Threaded Rigid Conduits Entering Cabinets Applications • To effectively seal one or more single or multiple conductor cables against the entrance of water, damp or corrosive atmospheres, hot or cold air or dust. Features • For rubber or plastic insulated cables in rigid conduit.• Provides an ample sealing compound chamber for use indoors or outdoors.• Sealing Compound is not included and must be ordered separately.• For applications involving IMC, EMT or PVC conduit, a short nipple of rigid conduit should be used entering the bottom threaded hub.• Lay-In-Lug™ Grounding Lug can be mounted on Terminator Body.• Can be field-drilled. Standard Materials • 1” and 1-1∕4” body - steel• Larger bodies - malleable or ductile iron Standard Finishes • 1” and 1-1∕4” body - zinc electroplated• Larger bodies - hot dip galvanized• Sealing disc - canvas bakelite Options • Steel Bodies 1” and 1-1∕4” are available with ot dip galvanized finish.• Fittings can be furnished for more than four wires or wires of varying sizes.• Due to the possibility of Magnetic Induction Heating, a single alternating current conductor should not be used in iron fittings. • Contact your local representative for price and availability on above options. Certifications and Compliances • CSA Certified: 11584 Max. Diameter of Wire Permitted - Millimeters (Inches) Dimensions in Millimeters (Inches) Conduit Size 1* Wire 2 Wires 3 Wires 4 Wires Maximum Diameter "A" Min."B" Approx.Compound Reqd.Pints Catalog Number 1”19.81 (0.78)9.65 (0.38)8.64 (0.34)7.87 (0.31)44.45 (1.75)25.4 (1)28.7 (1.13)1/20 HRK-100 1-1/4”25.91 (1.02)13.97 (0.55)12.7 (0.5)11.18 (0.44)60.45 (2.38)25.4 (1)31.75 (1.25)1/20 HRK-125 1-1/2”30.48 (1.2)16 (0.63)14.99 (0.59)12.95 (0.51)66.8 (2.63)25.4 (1)31.75 (1.25)1/8 HRK-150 2”38.86 (1.53)20.57 (0.81)18.54 (0.73)16.51 (0.65)79.5 (3.13)28.7 (1.13)38.1 (1.5)1/6 HRK-200 2-1/2”46.48 (1.83)24.64 (0.97)23.62 (0.93)19.81 (0.78)92.2 (3.63)35.05 (1.38)44.45 (1.75)1/3 HRK-250 3”57.91 (2.28)30.73 (1.21)29.46 (1.16)24.64 (0.97)111.25 (4.38)38.1 (1.5)47.75 (1.88)1/2 HRK-300 3-1/2”67.31 (2.65)35.56 (1.4)34.04 (1.34)28.45 (1.12)127 (5)38.1 (1.5)47.75 (1.88)1/2 HRK-350 4”76.2 (3)40.13 (1.58)38.61 (1.52)32.26 (1.27)139.7 (5.5)38.1 (1.5)47.75 (1.88)2/3 HRK-400 5”95.25 (3.75)50.55 (1.99)48.51 (1.91)40.64 (1.6)174.75 (6.88)41.4 (1.63)60.45 (2.38)1 HRK-500 Existing Conduit Existing Cabinet Type HRK TO ORDER SPECIFY: 1. Catalog Number 2. Number of conductorsr 3. Diameter over insulation of each cable B A Visit our website at www.ozgedney.com or contact us at (800) 621-1506. © January 2016 513 www.carlon.com174 Rigid Nonmetallic Conduit – Couplings Std.Part Ctn.A BCLNo. Size Qty.Typical I.D. O.D. Typical E940D 1/2 150 .852 .836 .728 17/64 11/16 11/2 E940E 3/4 100 1.064 1.046 .840 1 5/16 3/4 15/8 E940F 1 50 1.330 1.310 1.210 1 5/8 15/16 2 E940G 1 1/4 30 1.677 1.655 1.535 1 63/64 1 2 1/8 E940H 1 1/2 25 1.918 1.894 1.755 2 15/64 11/8 23/8 E940J 2 30 2.393 2.369 2.190 247/64 13/16 21/2 E940K 21/2 20 2.890 2.868 2.688 35/16 133/64 33/16 E940K-CAR 2 1/2 4 2.890 2.868 2.688 3 5/16 133/64 33/16 E940L 3 25 3.515 3.492 3.375 3 31/32 13/4 313/32 E940L-CAR 3 5 3.515 3.492 3.375 3 31/32 13/4 313/32 E940M 3 1/2 20 4.015 3.992 3.780 4 9/16 13/4 35/8 E940N 4 15 4.515 4.491 4.265 5 3/32 125/32 33/4 E940N-CAR 4 5 4.515 4.491 4.265 53/32 125/32 33/4 E940P 5 8 5.593 5.553 5.097 6 1/4 15/16 41/16 E940R 6 5 6.658 6.614 6.115 7 1/2 23/16 45/8 All socket fittings should be attached Using Carlon solvent cement. Using Carlon fittings with Carlon nonmetallic conduit insures system integrity. Standard Couplings Socket type for joining nonmetallic conduit. Special Long Line Couplings Std. Std. Ctn.Part No.Size Ctn. Qty. Wt. (lbs.) E941H 11/2 40 9 E941J 2 25 8 E941K 2 1/2 15 8 E941L 3 15 14 E941N 4 10 15 E941PF 5 4 12 E941RF 6 5 21 Long Line Couplings Couplings E32447 Except where noted by Short Expansion Couplings (Expands to a maximum of 2")Std.Part No.Size Ctn. Qty. E955D 1/2 40 E955E 3/4 40 E955F 1 25 E955G 1 1/4 15 E955H 1 1/2 10 E955J 2 6 E32447 E33447 Expansion Fittings (For Use with Schedule 40 & 80 Conduit) E945 series expansion fittings are designed to compensate for length changes due to temperature variations in exposed conduit runs. Coupling Male Terminal Travel End Adapter End Std. Length Part No. Part No. Size Ctn. Qty. (in.) E945D E945DX 1/2 20 4" E945E E945EX 3/4 15 4" E945F E945FX 1 10 4" E945G E945GX 1 1/4 54" E945H E945HX 1 1/2 54" E945J E945JX 2 15 8" E945K E945KX 2 1/2 10 8" E945L E945LX 3 10 8" E945M E945MX 31/2 58" E945N E945NX 4 5 8" E945P E945PX 5 1 8" E945R E945RX 6 1 8" Male terminal adapter endCoupling end Fabricated Expansion Couplings Std. TravelPart Ctn. LengthNo. Size Qty. (in.) E945KXL 21/2 10 12 •EXCLUSIVE Molded in Mid-point indicator on the piston. •EXCLUSIVE 2" Expansion Fitting with an 8" travel distance. •Two-piece molded design with lubricated seals for easier move- ment for the life of the product. •Ridges on the fitting for easier installation (Sizes 2" through 6" only). •Male terminal Adapter End design (1/2" – 2"NPT Threads, and 2 1/2" –6" NPSC Threads). •Two O-Rings to prevent leakage. •Can be installed vertically or horizontally. E33447 Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com 175 Rigid Nonmetallic Conduit – Adapters Part Std. A B Min. Max. C S L No. Size Ctn.Qty.Typical D OD Typical E943D 1/2 150 .852 .836 .597 11/8 5/8 9/16 15/16 E943E 3/4 125 1.064 1.046 .800 111/32 3/4 9/16 13/8 E943F 1 50 1.330 1.310 1.018 1 5/8 1 11/16 125/32 E943G 1 1/4 50 1.677 1.655 1.332 2 1/32 1 3/4 115/16 E943H 1 1/2 25 1.918 1.894 1.566 2 5/32 13/16 3/4 21/16 E943J 2 50 2.393 2.369 2.000 2 21/32 13/16 3/4 21/8 E943K 2 1/2 25 2.890 2.868 2.376 3 5/16 13/4 7/8 27/8 E943K-CAR 2 1/2 5 2.890 2.868 2.376 3 5/16 13/4 7/8 27/8 E943L 3 45 3.515 3.492 2.954 4 115/16 7/8 31/16 E943L-CAR 3 5 3.515 3.492 2.954 4 115/16 7/8 31/16 E943M 31/2 30 4.015 3.992 3.440 41/2 27/16 17/8 37/16 E943N 4 20 4.515 4.491 3.940 5 3/32 23/8 7/8 31/2 E943N-CAR 4 20 4.515 4.491 3.940 5 3/32 23/8 7/8 31/2 E943P 5 5 5.593 5.553 4.815 6 1/4 21/3 1315/16 E943R 6 10 6.658 6.614 5.860 7 1/2 23/8 133/8 Male Terminal Adapters For adapting nonmetallic conduits to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on other. Part Std.A B Min. Max. C T LNo. Size Ctn. Qty.Typical D OD Typical E942D 1/2 150 .852 .836 .620 1 7/64 11/16 3/4 19/16 E942E 3/4 100 1.064 1.046 .822 1 5/16 13/16 3/4 15/8 E942F 1 50 1.330 1.310 1.046 1 5/8 15/16 7/8 115/16 E942G 11/4 30 1.677 1.655 1.377 163/64 1 7/8 2 E942H 11/2 25 1.918 1.894 1.607 25/32 11/8 7/8 27/32 E942J 2 30 2.393 2.369 2.064 247/64 13/16 125/16 E942K 2 1/2 20 2.890 2.868 2.450 3 11/32 15/8 11/8 215/16 E942K-CAR 2 1/2 4 2.890 2.868 2.450 3 11/32 15/8 11/8 215/16 E942L 3 25 3.515 3.492 3.000 3 31/32 13/4 11/8 31/16 E942L-CAR 3 3 3.515 3.492 3.000 3 31/32 13/4 11/8 31/16 E942M 3 1/2 20 4.015 3.992 3.500 4 1/2 17/8 11/8 31/4 E942N 4 15 4.515 4.491 4.000 5 1/64 211/8 313/64 E942N-CAR 4 7 4.515 4.491 4.000 51/64 211/8 313/64 E942NX9*4 15 E942P 5 8 5.593 5.553 5.047 6 1/4 115/16 11/16 33/16 E942R 6 6 6.658 6.614 6.055 7 1/4 21/8 11/16 33/8 E942RX*6 6 (Call for information) Female Adapters For adapting nonmetallic conduits to threaded fittings, metallic systems. Female threads on one end, socket end on other. *Long Line Adapter Adapters (Call for information) Special Schedule 40 Swedge Couplings *Consult factory for additional sizes Std. Std. Ctn.Part No. Size Ctn. Qty. Wt. (lbs.) E442K 21/2 20 13 E442R 6 6 27 E442T 8 2 17 Risers Schedule 40 Part A B C Thread Std.Std. Ctn. No. Size (Length)(Min.)Size Ctn. Qty. Wt. (lbs.) E954HX 1 1/2 80.00 1.567 .950 11/2"NPT 1 3.8 E954J 2 60.00 2.024 .825 2"NPT 1 3.7 E954JX 2 80.00 2.024 .825 2"NPT 1 5.0 E954K 21/2 60.00 2.418 .812 21/2"NPSC 1 6.0 E954KX 2 1/2 80.00 2.418 .812 2 1/2"NPSC 1 8.4 E954L 3 60.00 3.012 .798 3"NPSC 1 8.7 E954LX 3 80.00 3.012 .798 3"NPSC 1 11.0 Std. Std. Ctn.Part No.Size Ctn. Qty. Wt. (lbs.) E948H 11/2 25 6 E948J 2 25 5 E948K 2 1/2 25 16 E948L 3 25 13 E948N 4 10 8 E948P 5 14 33 E948R 6 6 16 E948JR 2" (6" long)15 8 E948JS 2" (Sch. 40 Split Duct) 25 6 E948L12 3" (12" long)1 1 E948L6 3" (6" long)15 15 E948LS 3" (Sch. 40 Split Duct) 25 17 E948N12 4" (12" long)10 28 E948N7 4" (7" long)15 25 E948NS 4" (Sch. 40 Split Duct)10 15 E948PS 5" (Sch. 40 Split Duct) 1 2 E948R10 6" (10" long)6 25 E948R12 6" (12" long)6 25 E948RS 6" (Sch. 40 Split Duct) 1 2 Couplings Sleeve Coupling (For Repair Work) No Internal Stop E32447 Except where noted by Special Long Line Couplings — Sleeve Couplings Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com176 Rigid Nonmetallic Conduit – Fittings & Accessories Part Std. Ctn.L AC No.Size Qty.Typical Typical Typical E950ED 3/4"x 1/2" 100 1 5/32 13/64 11/32 E950FD-CAR 1" x 1/2"25111/32 3/16 57/64 E950FE 1" x 3/4" 100 1 11/32 3/16 11/64 E950GE-CAR 11/4" x 3/4" 10 115/32 3/16 11/64 E950GF 1 1/4" x 1" 50 1 15/32 3/16 19/64 E950HF-CAR 1 1/2" x 1" 10 1 19/32 3/16 19/64 E950HG-CAR 1 1/2" x 1 1/4" 10 1 19/32 3/16 117/64 E950JG-CAR 2" x 1 1/4"10 1 3/4 7/32 117/64 E950JH-CAR 2" x 11/2"10 13/4 7/32 125/64 E950KJ-CAR 21/2" x 2" 10 2 5/32 3/8 127/64 E950LJ-CAR 3" x 2" 10 2 1/8 1/4 17/8 E950LK 3" x 21/2"25 115/16 1/4 111/16 E950NL 4" x 3" 25 2 3/4 5/16 115/16 Reducer Bushings For connecting different sizes of conduit. Bell x Spigot. Reducer Plugs Std. Std. Ctn.Part No. Size Ctn. Qty. Wt. (lbs.) E971C 3/4" x 1/2" 100 2 E971D 1"x 3/4" 100 3 Plugs (Polyethylene) Std. Std. Ctn.Part No. Size Ctn. Qty. Wt. (lbs.) P258H 1 1/2"50 2 P258K 2 1/2" 25 1.5 Plugs with Pull Tabs (Polyethylene) Std. Std. Ctn.Part No. Size Ctn. Qty. Wt. (lbs.) P258JT 2 60 3 P258LT 3 30 3 P258NT 4 48 8 P258PT 5 30 6 P258RT 6 30 9 Reducers Plugs E32447 Except where noted by Part Std.Ctn.Min OD Max CM L No. Size Qty.D Typical X Typical E996D 1/2 100 .662 .840 1 7/64 23/32 27/32 E996E 3/4 100 .824 1.050 1 21/64 25/32 29/32 E996F 1 100 1.049 1.315 1 5/8 61/64 13/32 E996G 1 1/4 50 1.380 1.660 1 31/32 11/16 11/4 E996H 11/2 50 1.610 1.900 213/64 13/16 13/8 E996J 2 25 2.067 2.375 229/32 11/4 17/16 E996K-CAR 2 1/2 10 2.469 2.875 3 7/16 17/8 115/16 E996L 3 20 3.068 3.500 4 1/8 221/16 E996L-CAR 3 5 3.068 3.500 4 1/8 2 2 1/16 E996N 4 10 4.026 4.500 5 1/8 21/2 21/4 Box Adapters for Enclosures Adapts nonmetallic conduit to all electrical enclosures by inserting adapter through knockout and cementing into Carlon couplings. Threaded Adapters Std.Part No. Size Ctn. Qty. E9842D 1 1/2 25 E9842E 2 3/4 25 1 Fits 3/4" sockets 2 Fits 1" sockets Fabricated Reducers Std. Std. Ctn.Part No. Size Ctn. Qty. Wt. (lbs.) E952KJ 2 1/2"x 2" 48 28 E952LJ 3"x 2" 36 21 E952LK 3"x 21/2" 36 31 E952NL 4"x 3" 15 23 E952NM 4"x 31/2" 15 25 E952PN 5"x 4" 12 26 E952RP 6"x 5" 10 31 Fabricated Reducers (Male x Male) Reducers Adapters Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com Caps Service Entrance Caps Std. Ctn.Dimensions (in.) Part No. Size Qty. F G H E998D 1/2 5 .45 .45 – E998E 3/4 20 .45 .45 – E998E-CAR 3/4 5 .45 .45 – E998F 1 15 .59 .58 – E998F-CAR 1 5 .59 .58 – E998G-CAR 11/4 5 .74 .71 .50 E998H-CAR 11/2 5 .74 .71 .50 E998J-CAR 2 5 .83 .78 .56 E998K-UPC 2 1/2 2 1.70 1.31 1.00 E998L 3 2 1.70 1.31 1.00 E998N 4 2 2.25 1.88 1.31 www.carlon.com 177 Rigid Nonmetallic Conduit – Fittings & Accessories End Bells Offset Std.Std. Ctn. Qty.Part No. Size Ctn. Qty. Wt. (lbs.) E994DR-CAR 1/2 25 3 E994ER-CAR 3/4 15 2 E994F 1 50 12 End Bells Std. Std.Ctn. Ctn.Part No.Size Qty. Wt. (lbs.) E997F 1 50 1 E997F-CAR 1 15 1 E997G 1 1/4 35 1 E997G-CAR 11/4 15 1 E997H 1 1/2 30 1 E997H-CAR 1 1/2 10 1 E997J 2 40 1 E997J-CAR 2 10 1 E997K 2 1/2 30 2 E997K-CAR 21/2 10 2 E997L 3 50 2 E997L-CAR 3 10 2 E997M 31/2 40 10 E997N 4 30 11 E997P 5 15 10 E997R 6 10 7.4 E997T 8 3 14.55 Part Std. Std. No. Size Ctn. Qty. Wt. (lbs.) E949J5 2" x 5" 50 10 E949J6 2" x 6" 25 12 E949JN 2" x 4"25 7 E949JX 2" x 8" 12 7 E949LR 3" x 6" 20 21 E949N5 4" x 5" 20 2 E949NR 4" x 6" 15 21 E949R5 6" x 5"12 27 E949RX 6" x 8" 6 17 Fabricated End Bells Schedule 40 Meter Offset Std.Part Ctn.No. Size Qty. Offset A E995G 1 1/4 15 0.758 4.230 E995G-CTN 1 1/4 6 0.758 4.230 E995J 2 8 0.684 4.270 Offsets E32447 Except where noted by End Caps Std. Std.Ctn. Ctn.Part No. Size Qty. Wt. (lbs.) E958D 1/2 100 3 E958E 3/4 100 4 E958F 1 75 5 E958G 11/4 40 4 E958H 11/2 30 4 E958J 2 25 5 E958K 2 1/2 10 4 E958L 3 10 5 E958N 4 5 17 E958P 5 5 11 E958R 6 5 13 PVC Riser Caps Std. Std.Ctn. Ctn.Part No. Size Qty. Wt. (lbs.) E935J 2 25 9 E935L 3 25 18 E935N 4 25 18 E935P 5 25 35 E935R 6 10 13 A Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com178 Rigid Nonmetallic Conduit – Fittings & Accessories Flat Sealing Washer Part No. Size Std. Ctn. Qty. E943DW 1/2 125 E943EW 3/4 125 E943FW 1 100 E943GW 1 1/4 50 E943HW 11/2 50 E943JW 2 25 Part No.Size Std. Ctn. Qty. LT9LD 1/2 1200 LT9LE 3/4 700 LT9LF 1 600 PVC Lock Nut HOLFORM nonmetallic concrete sleeve forms are the easy way to form holes in concrete.They install in seconds with nails, screws or staples and are easily removed. Concrete will not adhere to them. HOLFORMS are adjustable to any slab thickness. Where a waterproof termination is required into any enclosure (metallic or nonmetallic), install the neoprene washer over the threads of a terminal adapter before inserting into the enclosure. Use a standard locknut or threaded bushing to secure the assembly. Std. A B C D Part No. Size Ctn. Qty. Typical Typical Typical Typical E990D 1/2 75 .852 .836 2.187 .718 E990DR-CAR 1/2 25 .852 .836 2.187 .718 E990E 3/4 50 1.064 1.046 2.531 .781 E990ER-CAR 3/4 20 1.064 1.046 2.531 .781 Gasket included. HOLFORM™ Concrete Sleeves Min.Std. Std.O.D.Ctn. Ctn.Part No. A B Qty. Wt. (lbs.) E92CSH 1 1/2 13/4 20 3 E92CSJ 2 2 13/32 25 6 E92CSL 3 3 13/32 25 8 E92CSN 4 4 13/32 18 8 E92CSP 5 5 13/32 15 8 E92CSR 6 6 13/32 12 8 Access Pull Elbows Pull Elbows SleevesWashers Lock Nuts E32447 Except where noted by Conduit Bodies Part No. Size Vol.Cu. In.Std. Ctn. Qty. E970CD 1/2 15.16 15 E970CE 3/4 15.16 15 Type X with Cover Four knock-out type socket openings, 90° spacing.Available with 1/2” or 3/4” socket outlets. Includes cover and gasket. Supplied with 4 stainless steel cover screws.Diameter 41/8",Thickness 1/4". *Not designed for use with wiring devices or light fixtures. Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com184 Rigid Nonmetallic Conduit – Support Straps B Size:inches Std. Std. Ctn.Part No. (mm) Ctn. Qty. Wt. (lbs.) A B C D F G H J R E978DC-CAR 1/2" 40 1 0.80 .75 1.63 0.75 .59 .99 1.36 .21 1.67 (16)(20.3) (1.90) (41.4) (19.1) (14.9) (25.1) (34.5) (5.33) (42.4) E978EC-CAR 3/4" 40 3 1.00 .88 1.92 0.75 .70 1.20 1.57 .21 1.96 (21)(25.4) (22.4) (48.7) (19.1) (17.8) (30.4) (39.9) (5.33) (49.8) E978FC-CAR 1" 30 4 1.20 1.02 2.17 0.75 .83 1.43 1.84 .21 2.22 (27)(30.5) (25.9) (55.1) (19.1) (21.1) (36.3) (46.7) (5.33) (56.3) Single Mount Single Mount Double Mount Snap Strap®Conduit Support Straps Carlon’s Snap Strap®offers a unique support strap designed especially for the installation of PVC conduit.Also usable for installations of rigid steel.This high strength, nonmetallic clamp allows conduit to expand and contract freely, eliminating the bowing commonly seen from the expansion and contraction of conduit caused by varying temperature changes. Finished installations have a neat, attractive appearance on exposed applications. To be used in accordance with conduit spacing requirements per the NEC, Section 352.30.This part is not supplied with screws. • UV inhibited for use in direct sunlight Size: inches Std. Std. Ctn. Part No. (mm) Ctn. Qty. Wt. (lbs.) A B C D F G H J R E978GC-CAR 1 1/4" 15 4 1.66 2.75 3.23 1.00 .95 1.78 2.15 .218 3.28 (35)(42.16) (69.9) (82.0) (25.4) (24.1) (45.2) (54.61) (5.54) (83.3) E978HC-CAR 1 1/2" 15 5 1.92 3.05 3.53 1.00 1.08 2.04 2.40 .218 3.58 (41)(48.77) (77.5) (89.7) (25.4) (27.4) (51.8) (60.96) (5.54) (90.9) E978JC-CAR 2" 10 5 2.34 3.50 4.00 1.00 1.31 2.48 2.86 .218 4.06 (53)(59.44) (88.9) (101.6) (25.4) (33.3) (63.0) (72.64) (5.54) (103.1) Double Mount Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com 185 Rigid Nonmetallic Conduit – Clamps Conduit Clamps Conduit Clamp Size: Std. Std.Part inches Ctn. Ctn.Wt.No. (mm) Qty. (lbs.) A B C D E F G H J E977DC 1/2" 100 1.2 0.892 1.71 2.16 0.50 .14 .42 .866 1.04 .260 (16)(22.6) (43.4) (54.8) (12.7) (3.5) (10.6) (21.9) (26.4) (6.6) E977EC 3/4" 100 1.4 1.102 1.97 2.40 0.50 .14 .525 1.076 1.255 .260 (21)(27.9) (50.0) (60.9) (12.7) (3.5) (13.3) (27.3) (31.8) (6.6) E977FC 1" 100 2 1.39 2.25 2.81 0.594 .14 .658 1.342 1.574 .260 (27)(35.3) (57.1) (71.3) (15.0) (3.5) (16.7) (34.0) (39.9) (6.6) E977GC 1 1/4" 50 5 1.714 2.68 3.28 .64 .15 .83 1.687 1.89 .320 (35)(43.5) (68.0) (83.3) (16.2) (3.8) (21.0) (42.8) (48.0) (8.1) E977HC 1 1/2" 50 6 1.92 2.82 3.44 .70 .15 .97 1.93 2.12 .312 (41)(48.7) (71.6) (87.3) (17.7) (3.8) (24.6) (49.0) (53.8) (7.9) E977JC 2" 25 4.5 2.54 3.54 4.18 .76 .16 1.05 2.29 2.49 .315 (53)(64.5) (89.9) (106.1) (19.3) (4.0) (26.6) (58.1) (63.2) (8.0) E977KC-CAR 2 1/2" 25 1.4 2.86 4.50 5.46 1.00 .20 1.43 2.86 3.12 .36 (63)(72.6) (114.3) (138.7) (25.4) (5.08) (36.3) (72.6) (79.2) (9.14) E977LC-CAR 3" 20 1.4 3.47 5.00 6.00 1.00 .20 1.74 3.48 3.70 .36 (78)(88.2) (127.0) (152.4) (25.4) (5.08) (44.3) (88.4) (94.0) (9.14) E977NC-CAR 4" 15 12.2 4.366 6.15 7.20 1.00 .20 2.32 4.50 4.70 .36 (103)(110.9) (156.2) (182.9) (25.4) (5.08) (58.8) (114.3 (119.4) (9.14) Nonmetallic Clamps Nonmetallic clamps offer the same chemical resistance as Carlon nonmetallic conduits for a complete, corrosion resistant system. To be used in accordance with conduit spacing requirements per the NEC, Section 352.30. • UV inhibited for use in direct sunlight *Note:Some clamp applications require 2 screws, 2 nuts and 2 washers. Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com 187 Rigid Nonmetallic Conduit – Expansion and Contraction Temperature Considerations for Rigid Nonmetallic Conduit Compensation for Linear Expansion Expansion and Contraction Like all construction materials, PVC will expand or contract with variations in temperatures.The coefficient of linear expansion in PVC conduit is 3.38 x 10-5 in./in./°F as compared to 1.2 x 10-5 for aluminum and 0.6 x 10-5 for steel. An expansion coupling is needed whenever the change in length due to temperature variation will exceed 1/2 in. Add 30°F to the estimated temperature range when conduit is installed in direct sunlight to allow for radiant heating. An expansion coupling consists of two sections of conduit, one telescoping inside another.When installing expansion couplings, alignment of piston and barrel is important. Be sure to mount expansion joint level for best performance. For a vertical run, the expansion coupling must be installed close to the top of the run with the barrel jointing down, in order that rain water does not run into the opening.The lower end of the conduit run must be secured at the bottom so that any length change due to temperature variation will result in an upward movement. Expansion Characteristics of PVC Rigid Nonmetallic Conduit Coefficient of Thermal Expansion = 3.38 x 10-5 in./in./°F Length Length Length Length Change in Change in Change in Change in Temperature inches per Temperature inches per Temperature inches per Temperature inches per Change in 100 Ft.of Change in 100 Ft.of Change in 100 Ft. of Change in 100 Ft. of Degrees F PVC Conduit Degrees F PVC Conduit Degrees F PVC Conduit Degrees F PVC Conduit 5 0.2 55 2.2 105 4.2 155 6.3 10 0.4 60 2.4 110 4.5 160 6.5 15 0.6 65 2.6 115 4.7 165 6.7 20 0.8 70 2.8 120 4.9 170 6.9 25 1.0 75 3.0 125 5.1 175 7.1 30 1.2 80 3.2 130 5.3 180 7.3 35 1.4 85 3.4 135 5.5 185 7.5 40 1.6 90 3.6 140 5.7 190 7.7 45 1.8 95 3.8 145 5.9 195 7.9 50 2.0 100 4.1 150 6.1 200 8.1 The expansion joint must be installed to allow both expansion and contraction of the conduit run.The correct piston opening for any installation condition should use the following formula: Determine the Piston Opening O= ET max - T installed T[ ] Where: O = Piston opening (in.) T max = Maximum anticipated temperature of conduit (°F) T inst. = Temperature of conduit at time of installation (°F) T=Total change in temperature of conduit (°F) E=Expansion allowance built into each expansion coupling (in.) 380 ft. of conduit is to be installed on the outside of a building exposed to the sun in a single straight run. It is expected that the conduit will vary in temperature from 0°F in the winter to 140°F in the summer (this includes the 30°F for radiant heating from the sun.) The installation is to be made at a conduit temperature of 90°F. From the table, a 140°F temperature change will cause a 5.7 in. length change in 100 ft. of conduit.The total change for this example is 5.7" x 3.8 = 21.67" which should be rounded to 22". The number of expansion couplings will be 22"x coupling range (4" for Carlon trade sizes 1/2" through 1-1/2",and 8" for sizes 2" through 6".) If the E945D coupling is used, the number will be 22"x 4 = 5.50 which should be rounded to 6.The coupling should be placed at 62 ft. intervals (380 x 6). the proper piston setting at the time of installation is calculated as explained above. Example O= 4.0 = 1.4 in.140 - 90 140[ ] Insert the piston into the barrel to the maximum depth. Place a mark on the piston at the end of the barrel.To properly set the piston, pull the piston out of the barrel to correspond to the 2.1 in. calculated above. See drawing at lower left. Summary 1.Anticipate expansion and contraction of PVC conduit in aboveground, exposed installation. 2. Use an expansion coupling when length change due to temperature variation will exceed 1/2". 3. PVC conduit expands 4.1" for each 100 feet of run and a 100°F temperature change. 4.Align expansion coupling with the conduit run to prevent binding. 5. Follow the instructions to set the piston opening. 6. Rigidly fix the outer barrel of the expansion coupling so it cannot move. Mount the conduit connected to the piston loosely enough to allow the conduit to move as the temperature changes. Solvent Weld Solvent WeldMaximum Depth Mark Piston OpeningPipe strap should be anchored tightly to barrel Pipe strap mounted loosely to allow movement Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com188 Rigid Nonmetallic Conduit – Technical Information Corrosion Resistance of Carlon Schedule 40 and Schedule 80 PVC Conduit and Fittings Carlon Schedule 40 and Schedule 80 are generally acceptable for use in environments containing the chemicals below.These environmental resistance ratings are based upon tests where the specimens were placed in complete submergence in the reagent listed. Schedule 40 and Schedule 80 can be used in many process areas where chemicals not on this list are manufactured or used because worker safety requirements dictate that any air presence or splashing be at a very low level. If there are any questions for specific suitability in a given environment, prototype samples should be tested under actual conditions. Acetic Acid O-20% Acetic Acid 20-30% Acetic Acid 3O-60% Acetic Acid 80% Acetic Acid – Glacial Acetic Acid Vapors Acetylene Adipic Acid Alum Aluminum Chloride Aluminum Fluoride Aluminum Hydroxide Aluminum Oxychloride Aluminum Nitrate Aluminum Sulfate Ammonia-Dry Gas Ammonium Bifluoride Ammonium Carbonate Ammonium Chloride Ammonium Hydroxide 28% Ammonium Metaphosphate Ammonium Nitrate Ammonium Persulfate Ammonium Phosphate – Neutral Ammonium Sulfate Ammonium Sulfide Ammonium Thiocyanate Amyl Alcohol Anthraquinone Anthraquinonesulfonic Acid Antimony Trichloride Aqua Regia Arsenic Acid 80% Arylsulfonic Acid Barium Carbonate Barium Chloride Barium Hydroxide Barium Sulfate Barium Sulfide Beet – Sugar Liquor Benzine Sulfonic Acid 10% Benzoic Acid Bismuth Carbonate Black Liquor (Paper Industry) Bleach – 12.5% Active CL2 Borax Boric Acid Brine Breeder Pellets – Dane. Fish Bromic Acid Bromine – Water Butane Butadiene Butyl Alcohol Butyl Phenol Butylene Butyric Acid Calcium Bisulfite Calcium Carbonate Calcium Chlorate Calcium Chloride Calcium Hydroxide Calcium Hypochlorite Calcium Nitrate Calcium Sulfate Carbonic Acid Carbon Dioxide Gas – Wet Carbon Dioxide – Aqueous Solution Carbon Monoxide Caustic Potash Caustic Soda Chloracatic Acid Chloral Hydrate Chlorine Gas (Dry) Chlorine Gas (Moist) Chlorine Water Chlorosulfonic Acid Chrome Alum Chromic Acid 10% Chromic Acid 30% Chromic Acid 40% Chromic Acid 50% Citric Acid Copper Chloride Copper Cyanide Copper Fluoride Copper Nitrate Copper Sulfate Cottonseed Oil Cresylic Acid 50% Crude Oil – Sour Crude Oil – Sweet Demineralized Water Dextrin Dextrose Diglycolic Acid Disodium Phosphate Ethyl Alcohol Ethylene Glycol Fatty Acids Ferric Chloride Ferric Nitrate Ferric Sulfate Ferrous Chloride Ferrous Sulfate Fluorine Gas – Wet Fluorine Gas – Dry Fluoroboric Acid Fluorosilicic Acid Formaldehyde Formic Acid Fructose Gallic Acid Gas – Coke Oven Gas – Natural (Dry) Gas – Natural (Wet) Gasoline – Sour Gasoline – Refined Glucose Glycerine (Glycerol) Glycol Glycolic Acid Green Liquor (Paper Industry) Heptane Hexanol,Tertiary Hydrobromic Acid 20% Hydrochloric Acid 0% - 25% Hydrochloric Acid 25% - 40% Hydrocyanic Acid or Hydrogen Cyanide Hydrofluoric Acid 10% Hydrofluorosilicic Acid Hydrogen Phosphide Hydrogen Sulfide – Dry Hydrogen Sulfide – Aqueous Solution Hydroquinone Hydroxylamine Sulfate Iodine Kerosene Lactic Acid 28% Lauric Acid Lauryl Chloride Lauryl Sulfate Lead Acetate Lime Sulfur Linoleic Acid Linseed Oil Lubricating Oils Magnesium Carbonate Magnesium Chloride Magnesium Hydroxide Magnesium Nitrate Magnesium Sulfate Maleic Acid Malic Acid Mercuric Chloride Mercuric Cyanide Mercurous Nitrate Mercury Methyl Sulfate Methylene Chloride Mineral Oils Naphthalene Nickel Chloride Nickel Nitrate Nitric Acid,Anydrous Nitric Acid 20% Nitric Acid 40% Nitric Acid 60% Nitrobenzene Nitrous Oxide Oils and Fats Oils – Petroleum – (See Type) Oleic Acid Oxalic Acid Palmitic Acid 10% Perchloric Acid 10% Phenylhydrazine Hydrochloride Phosgene, Gas Phosphoric Acid – 0-25% Phosphoric Acid – 25-50% Phosphoric Acid – 50-85% Photographic Chemicals Plating Solutions Potassium Bicarbonate Potassium Bichromate Potassium Borate Potassium Bromide Potassium Carbonate Potassium Chloride Potassium Chromate Potassium Cyanide Potassium Dichromate Potassium Ferricyanide Potassium Ferrocyanide Potassium Fluoride Potassium Hydroxide Potassium Nitrate Potassium Perborate Potassium Perchlorite Potassium Permanganate 10% Potassium Persulfate Potassium Sulfate Propane Propyl Alcohol Silicic Acid Silver Cyanide Silver Nitrate Silver Plating Solutions Sodium Acetate Sodium Arsenite Sodium Benzoate Sodium Bicarbonate Sodium Bisulfate Sodium Bisulfite Sodium Bromide Sodium Chlorate Sodium Chloride Sodium Cyanide Sodium Dichromate Sodium Ferricyanide Sodium Ferrocyanide Sodium Fluoride Sodium Hydroxide Sodium Hypochlorite Sodium Nitrate Sodium Nitrite Sodium Sulfate Sodium Sulfide Sodium Sulfite Sodium Thiosulfate (Hypo) Stannic Chloride Stannous Chloride Stearic Acid Sulfur Sulfur Dioxide – Gas Dry Sulfur Trioxide Sulfuric Acid – 0-10% Sulfuric Acid – 10-75% Sulfuric Acid – 75-90% Sulfurous Acid Tannic Acid Tanning Liquors Tartaric Acid Titanium Tetrachloride Triethanolamine Trimethyl Propane Trisodium Phosphate Turpentine Urea Vinegar Whiskey White Liquor (Paper Industry) Wines Zinc Chloride Zinc Chromate Zinc Cyanide Zinc Nitrate Zinc Sulfate Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com www.carlon.com 189 Rigid Nonmetallic Conduit – Specification Format A.The Carlon rigid nonmetallic conduit system shall be installed as indicated on the drawings and as specified herein. B.All wiring shall be installed in Carlon rigid nonmetallic conduit. All conduit shall be secured by means of proper fittings.All fittings shall be Carlon. C.Carlon outlet boxes,fittings and junction boxes shall be used for all outlets, pull boxes and junction points.(Lighting fixtures shall not be supported or hung from PVC junction boxes but be supported in position by other means.) D.Exposed conduits shall be mounted securely by suitable hangers or straps with the maximum spacing of points of supports not greater than indicated by Section 352.30 of the NEC. E.Except where embedded in concrete or direct buried, Carlon conduit shall be supported to permit adequate lineal movement to allow for expansion and contraction of conduit due to temperature change. F.For aboveground installations where temperature change in excess of 14°C (25°F) is anticipated, expansion joints shall be installed. See Table 352.44(A) NEC for expansion characteristics. G.Proper care shall be taken when field bending is employed to maintain the internal diameter and wall thickness of the conduit. Suggested Format for Specifying Carlon Nonmetallic Conduit, Conduit Fittings and Junction Boxes Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Technical Services Tel: 888.862.3289www.tnb.com E-497Conduit & Fittings — Carlon® PVC Elbows, Conduit & FittingsCarlon® Snap-Loc® Duct Spacers provide stability, consistent separation and relieve direct stress for duct materials encased in concrete and direct-burial applications. Carlon® Snap-Loc® Spacers provide: • A side dovetail rail-and-groove design enabling side-by-side interchangeability of conduit spacer sizes while maintaining horizontal stability • Locking keyways incorporated into intermediate spacers eliminate the need for costly top spacers in each size. The locking keyways provide for the use of a beaded strap that secures the top section of conduit • 1" and 2" Snap-Loc® Reducers enable fixturing of 1" or 2" conduit inside larger spacers • The Snap-Loc® Rebar Holder provides stabilization on large banks of spacers Non-metallic Snap-Loc® Spacers are designed specifically for use with non-metallic duct, with maximum O.D. dimensions as specified in NEMA TC-2, TC-6 & 8 and ASTM F512. The innovative vertical and horizontal interlocking Snap-Loc® design has tapered joining slots with maximum tolerances for easy jobsite assembly. Important: The use of duct spacers for direct burial may result in excessive point deflections unless proper design engineering is applied, such as the proper compaction of the appropriate backfill material. Carlon® Snap-Loc® Spacers Rebar Holder Snap-Loc® Reducer Beaded Strap & Locking Key Way Installation Note The Spacers and Rebar Holder are designed with a dovetail tongue-and-groove feature for easy installation. If required to permanently fix the position of a group of Spacers and/or Rebar Holder, the following are recommended procedures: 1. Use Carlon® Quick-Set Cement glue during assembly or spot glue after assembly to secure. 2. During assembly, deform the edge of the tongue or groove portion of the dovetail slide with a pair of pliers or similar tool. This deformation will create an interference, restricting movement. 3. An assembled system may be wired together for additional support. Important: The use of duct spacers for direct burial may result in excessive point deflections unless proper design engineering is applied, such as the proper compaction of the appropriate backfill material. Note: Spacers are not UL® Listed. Spacers www.tnb.comUnited States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Technical Services Tel: 888.862.3289E-498Conduit & Fittings — Carlon® PVC Elbows, Conduit & Fittings Dimensions — Base Spacers CAT. NO.SIZE (IN.)A (IN.)C (IN.)D (DIA.) (IN.)STD. CTN. S288JHN 2 x 11⁄2 4.25 4.12 2.50 100 S288JJN 2 x 2 4.25 4.62 2.50 100 S288JLN 2 x 3 4.25 5.62 2.50 100 S288LHN 3 x 11⁄2 4.81 5.25 3.63 90 S288LJN 3 x 2 4.81 5.75 3.63 80 S288LLN 3 x 3 4.81 6.75 3.63 60 S288NFN 4 x 1 4.50 5.75 4.63 70 S288NHN 4 x 11⁄2 5.31 6.25 4.63 50 S288NJN 4 x 2 5.31 6.75 4.63 50 S288NLN 4 x 3 5.31 7.75 4.63 60 S288PHN 5 x 11⁄2 5.84 7.31 5.69 50 S288PJN 5 x 2 5.84 7.81 5.69 60 S288PLN 5 x 3 5.84 8.81 5.69 50 S288RHN 6 x 11⁄2 6.38 8.38 6.75 50 S288RJN 6 x 2 6.38 8.88 6.75 50 S288RLN 6 x 3 6.38 9.88 6.75 40 S288SHN 8 x 11⁄2 7.38 10.30 8.75 30 S288SJN 8 x 2 7.38 10.76 8.75 30 Dimensions — Intermediate Spacers CAT. NO.SIZE (IN.)A (IN.)C (IN.)D (DIA.) (IN.)STD. CTN. S289JHN 2 x 11⁄2 3.88 4.12 2.50 120 S289JJN 2 x 2 4.38 4.62 2.50 100 S289JLN 2 x 3 5.38 5.62 2.50 80 S289LHN 3 x 11⁄2 5.01 5.25 3.63 100 S289LJN 3 x 2 5.51 5.75 3.63 80 S289LLN 3 x 3 6.51 6.75 3.63 60 S289NFN 4 x 1 5.51 5.73 4.63 70 S289NHN 4 x 11⁄2 6.01 6.25 4.63 60 S289NJN 4 x 2 6.51 6.75 4.63 60 S289NLN 4 x 3 7.51 7.75 4.63 50 S289PHN 5 x 11⁄2 7.07 7.31 5.69 50 S289PJN 5 x 2 7.57 7.81 5.69 50 S289PLN 5 x 3 8.57 8.81 5.69 30 S289RHN 6 x 11⁄2 8.14 8.38 6.75 50 S289RJN 6 x 2 8.64 8.88 6.75 40 S289RLN 6 x 3 9.64 9.88 6.75 30 S289SHN 8 x 11⁄2 10.14 10.30 8.75 30 S289SJN 8 x 2 10.64 10.76 8.75 30 Accessories * First number indicates trade size of duct, second number indicates separation between conduits or ducts. Snap-Loc® Reducer CAT. NO.SIZE (IN.)STD. CTN. S287F 1 100 S287J 2 100 Beaded Strap CAT. NO.STD. CTN. S28612 1 Bag of 250 Rebar Holder CAT. NO.STD. CTN. S258RH 100 15" in length Specifications B C A 3" Standard for all Base Spacers (with the exception of the 4X1-S288NFN) Suggested Specification: (Duct) (Conduit) bank shall be encased in concrete with at least three inches of concrete at the top and bottom and two inches on each side. A horizontal and vertical separation between the ducts of ____* inches shall be maintained by installing Carlon® high-impact spacers with horizontal and vertical locking intervals of ____** feet. *Standard Separations of 1", 11⁄2", 2" and 3" are available. **Preferred interval between spacer assemblies is 8 to 10 feet. Hole Dia. = .688 min. .750 max. Carlon® Snap-Loc® Spacers (continued) Spacers United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Technical Services Tel: 888.862.3289www.tnb.com E-499Conduit & Fittings — Carlon® PVC Elbows, Conduit & FittingsVertical Interlocking With Reducer Horizontal Locking Carlon® Snap-N-Stac™ Combo Spacers One-way Three-way Installations Carlon® Snap-N-Stac™ Combo Duct Spacers are specifically designed to replace the two-piece base and intermediate spacer system, by combining the conventional base and intermediate spacer into a single unit. Manufactured out of highly engineered thermoplastic material, Snap-N-Stac™ Spacers are strong, durable and able to withstand the rigors of concrete construction. They feature an innovative horizontal and EXCLUSIVE vertical locking system, and can be used as either a base or intermediate spacer. Snap-N-Stac™ Spacers are available in one-way, two-way and three-way configurations (one-way and three-way only available in sizes 2" and 4"). They accept 2", 3", 4", 5" and 6" pipe and can be installed horizontally, vertically or turned upright for unique duct bank configurations. This NEW one-piece design makes underground duct bank installations faster and easier than the conventional two-piece system — saving material and labor costs. Carlon® Snap-N-Stac™ Combo Spacers…The IDEAL solution for underground duct bank installations. Features: • Conventional base and intermediate spacer in a single unit • Less inventory required • EXCLUSIVE vertical locking system • Horizontal locking system • Installs horizontally or turned upright • Molded-in rebar holder on two-way and three-way • One-, two- and three-way configurations (one-way and three-way only available in sizes 2" and 4") • Five sizes: 2", 3", 4", 5" and 6" • Reducer to accommodate smaller duct sizes • Can be used as either an intermediate or base spacer • Spacers interlock horizontally regardless of size • Non-metallic, non-corrosive, non-conductive • Strong and durable • Easy to handle • Fast installation Spacers www.tnb.comUnited States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Technical Services Tel: 888.862.3289E-500Conduit & Fittings — Carlon® PVC Elbows, Conduit & Fittings Installation Instructions IMPORTANT: 1. Snap-N-Stac™ Spacers are recommended for concrete-encased applications only. 2. The use of duct spacers for direct burial may result in excessive point deflections unless proper design engineering is applied, such as the proper compaction of the appropriate backfill material. Vertical Interlocking Slide spacers together “Feet Facing Feet” or “Feet Opposite.” Feet Facing Feet Opposite Molded-In Rebar Holder Carlon® Snap-N-Stac™ Combo Spacers (continued) Spacers United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Technical Services Tel: 888.862.3289www.tnb.com E-501Conduit & Fittings — Carlon® PVC Elbows, Conduit & FittingsVertical Free Standing If spacers are installed using free-standing method, it is recommended to install the spacer on the upper row mid-way between the two spacers on the bottom row. Reducer 1" and 2" Snap-Loc® Reducers enable fixturing of 1" and 2" conduit inside of larger spacers. Transition to Various Duct Sizes Install spacers side-by-side by inserting the male adapter into the female adapter. Note: All Snap-N-Stac™ spacers are designed to interlock horizontally, regardless of size. Odd Number of Ducts Two-way spacers, size 2" and 4" only, can easily be cut apart to produce two one-way spacers. Create three-way and five-way spacers using the one-way spacer. Install spacers side-by-side by inserting the male adapter into the female adapter. Installation Instructions Spacers