Loading...
HomeMy WebLinkAbout236513 -Separator Tower Filtration System. . . . . . . . . . . . . . . . . . . . . . . . . . . . D/E/F Services Group, LTD 1171 Voluntown Road Griswold, CT 06351 Phone: (860) 376-4896 Fax: (860) 376-1213 Submittal Transmittal TO: The Maggiore Companies 13 Wheeling Ave. Worburn, MA 01801 Date: 1/10/2020 Project # F29166 - F29166 Oxoboxo Submittal # 21 ATTN: Gifford Perry RE: (Lakos) Separator Tower Filtration System We are sending you the following:  Attached  Under Separate Cover Via:  1st Class Mail  Overnight  Facsimile  Pick-Up/Hand Deliver Copies Spec No. Description 1 236513 (Lakos) Separator Tower Filtration System Remarks: Please see the attached submittal for record. Releasing as per schedule. Received By: _________________________________ Date: ________________________ Signed: _______________________________ Title: _________________________________ Copy to: ___________________  Recipient’s Copy  Sign & Return  File Copy NORRIS & FERRARIS PHONE: (860) 651-1986 MANUFACTURERS REPRESENTATIVES FAX: (860) 651-0295 571 HOPMEADOW ST. SIMSBURY, CT. 06070 SUBMITTAL Architect: Paul B. Bailey Architect Engineer: Aztech Engineers Contractor: D/E/F Service Group PROJECT: Oxoboxo Lofts Sales Engineer: M. Webster Date: Jan 9th, 2020 For: SUBMITTAL TAG QTY EQUIPMENT DESCRIPTION 1 Lakos Separator Tower Filtration System. Model eTCX-0050 -EFS. 208/3 Includes: EFS purge valve, auto -purge timer, HOA switch, disconnect, pump soft starter, valve/gauge kit. NOTES: Unit shall be interlocked with CT pumps. Terminals provided in Lakos unit. Lakos HT Product Configurator Selection Summary Final Summary Selected Model: eTCX-0050 Highest efficiency Cooling Tower Basin Cleaning and Side Stream filtration system that removes fine solids (44 microns and larger in single pass and 25 microns and larger in recirculated systems) from HVAC open and closed loops. This packaged system reduces manual basin cleaning, equipment operating costs, maintenance costs, and water use. Selection Details Filtration Type Side Stream Voltage 208V 60 Hz Required Flow Rate 63 gpm Valve Kit eTCV Separator Accessibility Yes Purge Size 0.75" Filtration Level 44 Micron Inlet 2.5" Model eTCX-0050 Outlet 1.25" Purge Method Purge to Drain Pump HP 2 Purge EFS The above summary was generated by Lakos HT Product Configurator. The Configurator can be accessed at lakoshvac.com . For questions or concerns, contact Lakos at 1-559-255-1601 or email lit@lakos.com. Selection was generated on 12/12/2019 12:33 PM Pacific Standard Time. PAPER COPIES ARE UNCONTROLLED. APPROVED ENGINEERING CHANGE ORDER (ECO).ONLY BE INCORPORATED AS DIRECTED BY ANMAINTAINED BY A CAD SYSTEM. CHANGES SHALLTHIS DRAWING HAS BEEN GENERATED AND IS COMPONENT LIST: 1 ELECTRICAL CONTROL BOX 208V/230V/460V, 60Hz W/120V TRANSFORMER. 2 SEPARATOR: eHTX-0025-V. 3 PUMP: 2 HP CENTRIFUGAL, 3600 rpm, 208V/230V/460V, 60Hz. 4 INLET/OUTLET PRESSURE GAUGES: 0-100 psi, GLYCERIN-FILLED. 5 PURGE EQUIPMENT: EFS-07-120V. 6 STRAINER, SUCTION DIFFUSER. NOTES: INLET IS 2-1/2" PIPE (125# ANSI FLANGED).1. OUTLET IS 1-1/4" PIPE (GROOVED).2. PURGE OUTLET IS 3/4" PIPE.3. MAXIMUM PRESSURE: 150 psi (10.3 bar).4. MAXIMUM TEMPERATURE: 100ºF (37.8ºC).5. SPECIFIED FLOW RATES:6. BASIN SWEEPING- 50 gpm (15 m³/hr). SIDE STREAM & CLOSED LOOP- 65 gpm (22 m³/hr). FINISH: AS ASSEMBLED.7. POWER REQUIREMENT: 208V/230V/460V, 3PH, 60Hz. (CUSTOMER SPECIFIED)8. NEMA 4X MOTOR STARTER ENCLOSURE WITH9. SAFETY DISCONNECT AND H.O.A. SWITCH. APPROXIMATE DRY WEIGHT: 461 lbs (209 kg).10. INLET/OUTLET VALVE KIT RECOMMENDED: SEE FACTORY.11. MINIMUM PIPE FROM TOWER BASIN TO TC SYSTEM IS 2-1/2" PIPE.12. FLOODED SUCTION REQUIRED.13. 2-5/8"67 38-15/16"989 SUBMITTAL DRAWING This drawing is submitted for spatial consideration only. Do not pre-plumb to these dimensions. 5 12 3 39-3/4"1010 24"610 12-15/16"328 5-5/16"134 1" TYP25 3/4" TYP19 1/2" TYP13 10-9/16"269 12-9/16"319 TOP VIEW 13-3/8"340 9-1/8"232 FRONT VIEW PUMP & STRAINER 6 9-1/8"232 FRONT VIEW ROTATED STRAINER (STRAINER) - - 1/2" PER LAKOS SPEC AS ASSEMBLED - - STANDARD FRONT VIEW W/O STRAINER REVISION HISTORY ZONE REV DESCRIPTION DATE APPROVED C EXCEPT AS OTHERWISE PROVIDED BY CONTRACT, THIS DRAWING AND SPECIFICATIONS SHALL NOT BE REPRODUCED, COPIED OR USED AS THE BASIS FOR MANUFACTURE OR SALE OF MATTER DEPICTED HEREIN WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE CLAUDE LAVAL CORPORATION, OR ITS ASSIGNEES. D 3 SHREV.DWG NO.UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN: INCHES [mm] DECIMALS MATERIAL FINISH .XXX.XXXX TOLERANCES ARE: FRACTIONS ±±.XX WORK ORDER MFG ENGR SCALE QTY.CSIZE APPROVALS1/4°±.005.0005 ± .01 ± ANGLES DRAWN ENGINEERED FOR: TITLE DATE DWG NO. EST. WT.SHEET WWW.LAKOS.COMFRESNO, CALIFORNIA 93727CLAUDE LAVAL CORP. R REV. UNDERGROUND SURVEYS LAVAL eTCX-0050-EFS, TC SYSTEM HI EFFICIENCY eHTX-0025-V, 3/60/208, 230, 460V 135579 01 1:8 1 OF 1 13557901MODEL NO. B A A C D 4 12 2 143 4/26/13TRRDO NOT SCALE DRAWING 461 lb LAKOS eTCX SideStreamClean High Efficiency Systems Liquid-Solids Separation System Part I – General 1.01 Purpose A. The system will remove unwanted solids from a cooling tower sump/remote basin, or side-stream recirculated cooling water system using a centrifugal-action vortex separator. The liquid-solids separation system will help prevent particle fouling of the cooling system's components reduce maintenance and servicing routines, maintain optimum energy efficiency of the heat exchange process, limit blow down & chemical use practices and control harmful bacteria growth in the basin/sump or cooling water system. Fluid viscosity must be 100 SSU or less. B. Specified For Side Stream Use -- Control of solids in the recirculated cooling water system shall be accomplished via a side-stream flow of not less than 10-20% of the full-stream system flow through a completely assembled separation/filtration package. The package's pump shall provide sufficient pressure for the re-introduction of side-stream fluid back into system flow. 1.02 System Performance A. In a single pass through the eHTX separator system, given solids with a specific gravity of 2.6 and water at 1.0, performance is predictably 98% of 44 microns and larger. Additionally, particles finer in size, heavier by specific gravity and some lighter by specific gravity will also be removed. B. In a recirculating system, given solids with a given solids with a specific gravity of 2.6 and water at 1.0, 99% performance is predictable to as fine as 25 microns, with correspondingly higher aggregate performance percentages (up to 80%) of solids as fine as 2 microns. C. Separator performance must be supported by published independent test results from a recognized and identified agency. Standard test protocol of upstream injection, downstream capture and separator purge recovery is allowed with the 50-200 mesh particles to enable effective, repeatable results. Single pass test performance must be not less than 95% removal. Model tested must be of the same design series as specified unit. Part II - Products 2.01 Manufacturer A. The separator system shall be manufactured by LAKOS Filtration Systems, a division of Claude Laval Corporation in Fresno, California USA. Specific model designation is: eTCX-0050 2.02 eHTX Series Liquid-Solids Separator A. A tangential inlet and mutually tangential internal accelerating slots shall be employed to promote the proper velocity necessary for the removal of the separable solids. The internal accelerating slots shall be spiral-cut for optimal flow transfer, laminar action and particle influence into the separation barrel. The separator’s internal vortex shall allow this process to occur without wear to the accelerating slots. B. Separated particle matter shall spiral downward along the perimeter of the inner separation barrel, in a manner which does not promote wear of the separation barrel, and into the solids collection chamber, located below the vortex deflector stool. C. To insure maximum particle removal characteristics, eHTX Series Separator shall incorporate a enhanced vortex-induced pressure relief line (Vortube), drawing specific pressure and fluid from the separator’s solids collection chamber via the outlet flow’s vortex/venturi effect, thereby efficiently encouraging solids into the collection chamber without requiring a continuous underflow or excessive system fluid loss. D. System fluid shall exit the separator by following the center vortex in the separation barrel and spiral upward to the separator outlet. E. The separator shall feature the following access capabilities for either inspection or the removal of unusual solids/debris: 1. A hand-hole port at the collection chamber (eHTX models 3-1/2” and 4” only). 2. An upper chamber full sized grooved coupling or flanged top to allow complete access to the inlet chamber, acceleration slots, and internal separation barrel. F. The separator shall be of unishell construction with SA-36, SA-53B or equivalent quality carbon steel, minimum thickness of .25 inches (6.35 mm). Maximum operating pressure shall be 150 psi (10.3 bar), unless specified otherwise. G. Paint coating shall be oil-based enamel, spray-on, gloss black. H. Pressure gauges shall be included for the inlet/outlet of the separator. I. Inlet & outlet shall be grooved or flanged, size: 2.5” inlet 1.25”outlet J. Purge outlet shall be threaded, size: ¾” K. The separator shall operate within a flow range of: 60 GPM L. Pressure loss shall be between 2-15 psi (0.14-1.0 bar), remaining constant, varying only when the flow rate changes. 2.03 Purging & Solids Handling A. Evacuation of separated solids may be accomplished automatically, employing an electric actuated fail safe ball valve (EFS) with integrally-equipped programming for controlling the frequency and duration of solids purging; brass ball valve assembly; battery backup style fail safe control. 2.04 Suction Diffuser A. Provided with system to protect system pump from damage or fouling by larger solids or debris. B. Cast-iron housing; manual-cleaning; 1/8-inch (3.2 mm) or larger minimum mesh rating; stainless steel screen. 2.05 Pump A. End-suction, single stage; Premium Efficiency TEFC motor; cast iron housing; bronze or cast iron impeller; mechanical shaft seal (Viton-Silicon Carbide); flooded suction required. 2.06 Piping A. Schedule 40 galvanized carbon steel; reinforced rubber hose to solids recovery vessel; Piping on larger systems to be fabricated carbon steel pipe, painted or coated; Larger systems will require field assembly of piping between separator skid and pump skid. 2.07 Electrical Control A. IEC starter with overload module; HOA selector switch; NEMA-4X UL Listed enclosure; re-set/disconnect/trip switch; 120 volt, single phase control voltage; includes provision for using EFS purge valve assembly and timer; built-in amp meter; automatic low flow shutdown; BACnet and Modbus optional; 15 fault log memory. 2.08 Valves A. Ball valves on purge line for isolation of solids-handling/purging equipment. Optional inlet/outlet butterfly valve kit is provided. 2.10 Skid Plate A. Stainless steel, 3/16-inch (5 mm) minimum thickness on system up to eTCX-0410 Part III - EXECUTION 3.01 Installation A. Coordinate with the installing contractor to ensure equipment is installed in conformance with manufacturer’s recommendations and those found in the specification. B. If deficiencies are noted by the field service representative, the contractor shall make the necessary corrections and the manufacturer’s field service personnel will visit the installation site and oversee any corrections and or modifications required. A written report shall be filed with the Engineer at each visit. ____________________________________________________ Limited Warranty This product series is warranted to be free of defects in material or workmanship, given the following terms: LAKOS Separator: 5 years All other components: 12 months from date of installation; if installed 6 months or more after ship date, warranty shall be a maximum of 18 months from ship date. If a fault develops, notify us, giving a complete description of the alleged malfunction. Include the model number(s), date of delivery and operating conditions of subject product(s). We will subsequently review this information and, at our option, supply you with either servicing data or shipping instruction and returned materials authorization. Upon prepaid receipt of subject product(s) at the instructed designation, we will then either repair or replace such product(s), at our option, and if determined to be a warranted defect, we will perform such necessary product repairs or replace such product(s) at our expense. This limited warranty does not cover any products, damages or injuries resulting from misuse, neglect, normal expected wear, chemically-caused corrosion, improper installation or operation contrary to factory recommendation. Nor does it cover equipment that has been modified, tampered with or altered without authorization. No other extended liabilities are stated or implied and this warranty in no event covers incidental or consequential damages, injuries or costs resulting from any such defective product(s). LS-911 rev 3/15 1 eTCX Features and Benefits: • 99% filtration efficiency of solids down to 25 micron (2.6 Specific Gravity) and larger greatly reduces suspended solids in recirculated cooling tower water; significantly improving equipment life and removing food source for biological activity • Minimize tower nozzle clogging, protect basin floor from under-deposit corrosion, eliminate risk of injury associated with manual basin cleaning, and greatly reduce heat transfer loss in downstream equipment • eTCX System can be utilized for basin sweeping, side stream cleaning, and closed loop cleaning applications • NEMA Premium 1750RPM TEFC motor provides superior efficiency, greater returns on investment, and meets most urban noise abatement levels • Pumps feature precisely trimmed and dynamically balanced impellers that help extend pump seal and bearing life • Electric fail-safe valve (EFS) eliminates manual purging and automatically closes valve in event of power failure • eHB HydroBooster water nozzles operate as low as 10psi. 50% less psi than our standard HydroBoosters; reducing need for larger pumps • Solids Recovery Vessel (SRV) offers zero water loss and helps meet waste/chemical disposal requirements. eTCX System features SRV-833 - a larger SRV allowing for fewer bag changes • LAKOS SmartStart™ control panel features motor overload protection, under power (dry run) conditions. Control panel also logs last 15 faults and is user retrievable. Optional BACnet and Modbus compatibility modules are available from the factory. High Efficiency Tower Clean Systems Eliminate Basin Cleaning and Reduce Energy Consumption LAKOS High Efficiency eTCX Tower Clean Systems help keep the cooling tower basin free of suspended solids that cause scale, corrosion, fouling and biological activity. Controlling these factors leads to lower maintenance, improved chemical effectiveness, longer cooling tower and downstream equipment life, and a significant decrease in long-term water and energy costs. Side Stream Closed LoopBasin Sweeping FILTRATION APPLICATIONS: Zero Water Loss Options Available Zero Maintenance Options Available MAINTENANCESOLIDS METERWATER USAGE 25µm 5µm 44µm 74+µm High Med Low Micron Removalµm (microns) FLOW RATES: Basin Sweeping: 50 – 810 US gpm (11 – 184 m3/hr) Side Stream: 65 – 810 US gpm (15 – 184 m3/hr) Maximum Pressure Rating: 150 psi (10.3 bar) Maximum Fluid Operating Temperature: 100°F (37.8° C) Contact factory for high temperature models 2 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 32+ µm 23-32 µm 16-22 µm 11-15 µm 1-10 µmPerformance Microns (µm) at 2.6 Specific Gravity The above efficiency results were based upon 20% side stream within 16 hours. Field results may vary depending on side stream percentage and basin size. Performance results verified by independent testing. High Efficiency Basin Sweeping ADVANTAGES OF eTCX SYSTEM AVERAGE SYSTEM PUMP POWER REDUCTION AVERAGE SYSTEM NOISE REDUCTION (dB comparison) AVERAGE SYSTEM kW REDUCTION eTCX Systems 28.5%eTCX Systems 79.8% eTCX Systems 29.7% TC Systems TC Systems TC Systems 28.5% Less Energy Required 79.8% Less Noise 29.7% Decrease in system kW consumption AVERAGE SYSTEM PUMP POWER REDUCTION (per US gpm) eTCX Systems 34.4% TC Systems 34.4% Pump Power Reduction (P/gpm) LAKOS SYSTEM SYSTEM PUMP LOAD XXXX XXXXFILL Traditional side stream filtration systems take a percentage of the flow (generally 10-25% or less) from the main line using a by-pass directly to the filtration system. The filtered water is then returned to the main line. Basin sweeping is simply relocating the traditional side stream filtration system from the main line directly to the cooling tower basin, thus increasing the percentage of side stream filtration to 20% or more. Additional advantage is gained by recirculating the filtered water through a network of pipes and nozzles that sweep and direct other settled and suspended solids from the basin towards the filtration system – and away from the condenser water pump. Basin sweeping capacity is determined by the volume of water in the basin rather than assigning a percentage of the full flow, as is commonly done with traditional side stream applications. 99.5%99% 89%82% 70% Solids Removal Chart: Recirculated flow at 20% Side Stream Ask us about our ROI Calculator 3 eHB HydroBoosters™ HydroBoosters in action TC Systems in Aulani Disney Hawaii Resort, Hawaii USA HydroBooster Layout at Roseburg Forest Products, California USA ToTowerCleanSystem Filtered water to downstream to chillers/ heat exchangers Contaminants are directed to eTCX System Filtered water o ws to LAKOSHydroBoosters Coolin g Tower Tower Basin Sweeping witheTCX System andeHB HydroBoosters LAKOS eTCX System removes and collects solids 6x induced flow rate activity 1 US gpm enters HydroBooster eHB HydroBoosters operate at 10psi. 50% less than our standard HydroBoosters Directed turbulence maximizes cleaning efficiency in the tower basin/remote sump. LAKOS eHB HydroBoosters provide that turbulence with patented vortexing action. Consult LAKOS for technical assistance in basin sweeping layout and piping options. Basin Cleaning in a Factory Packaged Tower Basin Sweeping in a Field Erected Tower • Start with a clean basin. • Required submergence of 2” above centerline inlet of HydroBoosters. • Position the HydroBoosters to direct solids toward the filtration system’s pump intake and away from any other system pump suction areas. • Use a closed-loop header in order to equalize the pressure to each HydroBooster. • Eliminate weirs, baffles or other devices which may promote settling or dead spots within the sump. • Where possible, take advantage of any existing slopes to direct solids toward the low end of a sump. • When possible, position the system’s pump intake where solids are most likely to enter the sump. LAYOUT,HYDROBOOSTER CTSWEEP - NTS 1OF1 ALLYNT 02/11/13 CTSWEEP1--spacial &illustrativepurposes only. CONCEPTUAL DRAWINGCONCEPTUALDRAWINGCONCEPTUALDRAWINGCONCEPTUALDRAWINGCONCEPTUALDRAWING Thisdrawing issubmittedfor Do notpre-plumbtothese 4.SCHEDULE40/80 PVC PIPE RECOMMENDEDWHERE APPLICABLE. 1.HYDROBOOSTERSTOBEFLUSHWITHBOTTOMOFBASIN.2.ALLDIMENSIONS TOBE FIELD VERIFIEDBEFORE INSTALLATION.3.FLOODED SUCTIONREQUIRED BEFORE STARTING TC PACKAGE. dimensions. NOTES: 2"CLIPEYELET 1/2"MPTX3/4"NPTFHYDROBOOSTERADAPTER (28)HB-10-KHYDROBOOSTERW/ADAPTER (28)HBC-10-2002"CLIP EQUIPMENT: TCX-0280-SRV LAKOSREP: LAKOSRSM: PROJECT: HB-10-K DRILL9/16"HOLETHRUPIPETOACCEPTMALESTUBOFCLIP 3/4"SOCX3/4"NPTF 3/4"PIPEBYOTHERS 2"CLIPEYELET VERTICALINSTALLATION 3/4"PIPE(CUTTOFIT) 3/4"90°ELBOW 2"PVCPIPESCH40 1/2"MPTX3/4"FPT 2"CLIPEYELET HB-10-K HB-10-K 1/2"MPTX3/4"NPTFHYDROBOOSTERADAPTER 5.MULTIPLE TOWERS USINGONTCPACKAGEREQUIREEQUALIZERPIPINGBETWEEN EACHTOWER. LAKOS FILTRATION Installation Best Practices 4 Dual Tower Switching for Light Solids Loading LAKOS recommends one eTCX basin sweeping system per cell for maximum energy savings and reduced life-cycle costs. When short term budget needs demand, eTCX systems also provide the benefit of filtering two cooling tower cells alternately – without operator input. SYSTEM PUMP LOAD XXXX XXXXFILL XXXXXXXXFILL LAKOS SYSTEM SYSTEM PUMP LOADxx xxAlternating Kit Features and Benefits: • Provides primary and stand-by tower filtration • Use one filtration system to clean two cooling tower cells alternately. Economical basin sweeping solution for applications with light solids loading • Utilized when filtration requirements have larger horsepower (HP) needs and the environment is such that it will allow for smaller HP systems to alternate between cells • Automated valve switching operation eliminates manual switching in dual cell tower configurations SRV-833 Features and Benefits: • New Solids Recovery Vessel (SRV-833) features double capacity to allow for fewer bag change outs • Capture separated solids easily and return clean liquid back to eTCX pump suction; eliminating liquid loss • Continuous operation; remove collected solids without interrupting system flow for service • Lower waste treatment costs, meet waste disposal requirements and greatly reduce chemical loss • Indicator package (SRI-816) provides convenient way to determine bag change-outs • Optional dry contact available for remote monitoring with BMS (Building Management System) connection or audio/visual alarms for bag changes • For more information see LAKOS literature LS-622 Solids Recovery Vessel (SRV) 5 Features and Benefits: • Battery backup electric fail-safe option automatically closes valve in event of power failure • Eliminates manual purging • EFS actuator features an electronic circuit that automatically adjusts the motor speed (depending on torque variations) to keep cycle time constant – maintaining consistent purge durations • EFS actuator housing is made of a V0 self-extinguish class techno-polymer material for fire safety • Can be combined with an SRV to offer temporary hands-off operation • For more information see LAKOS literature LS-913 LAKOS SmartStart™ Electric Fail-Safe Valve (EFS) EFS Pump and Motor Protection • Low flow shutdown • Electronic overload protection, including locked rotor, cycle fault, phase imbalance, and maximum time to start • Ground fault protection Fault Reporting • Fault logging retains critical data • Last 15 fault types are recorded Purge and SRV • SmartStart™ panel features built-in default support for solids purge. This allows operator to switch between solids collection and/or solids purge without the need for a new control box. Optional BACnet or ModBus • Native RS-485 76800 BPS for high performance • Additional programmable digital input. Additional analog input, selectable between 0-10V,4-20mA, or 10k thermistor • Includes power metering display with programmable parameters LAKOS SmartStart™ Intelligent Control Panel NEMA 4x Rated The LAKOS SmartStart™ control panel protects the pump and motor by monitoring power and current to identify locked rotor, cycle faults, current phase imbalance, and under power (dry run) conditions. The control panel also logs last 15 faults and is user retrievable. Optional BACnet and Modbus compatibility modules are available from the factory. 6 HydroBoosters™ Model Connection Size Extension Pipe Size (minimum)Input Flow Input PSI eHB ½” (12.7mm) male NPT ¾” (19.05mm)10 US gpm (2m3/hr)10 psi NOTE: These flow rates are based on an input pressure of 10psi (.68 bar). Minimum water level above centerline of HydroBooster should be 2 inches (50.8 mm). Inlet/Outlet Premium Butterfly Valve Kits Model Inlet Valve Sizes Outlet Valve Sizes eTCV models 2.5” to 8” Flanged Butterfly Valves 1.25” to 4” Butterfly Valves 1.25” and 1.5” models are NPT ball valves High Efficiency Side Stream and Closed Loop Cleaning Side Stream Closed Loop BENEFITS: • Economical filtration solution • Large or variable flow application where full flow is not an option and basins are not accessible • Reduce suspended solids in main line flow • Easy to retrofit • Zero liquid loss options with LAKOS Solids Recovery Vessel • Zero filtration maintenance when using LAKOS automated purge valves BENEFITS: • Side stream filtration to remove solids generated in closed loops • Zero liquid (water or coolant) loss with Solids Recovery Vessel • Direct replacement for side stream bags or spiral wound cartridges XXXX XXXXFILL LAKOS SYSTEM LOAD SYSTEM PUMP XXXX XXXXFILL LOAD SYSTEM PUMP LAKOS SYSTEM Condenser Evaporator Closed loop Filtration, Data Center, Virginia USA Side Stream Filtration, Parkland Hospital, Texas USA 7 Models & Dimensions Basin Sweeping Configuration Flow Rate = Basin square footage Models eHTXSeparators Flow Rates1 Diffuser/Strainer inlet4 Separator outlet System Weight Pump HP/kW2 Full Load Amperage3 US gpm m3/hr lbs kgs 208V 230V 460V 575V eTCX-0050-SRV eHTX-0025 50 11 2-1/2”1-1/4”558 264 2 HP/1.48 kW 5.6 5.1 2.52 2.1 eTCX-0080-SRV eHTX-0040 80 18 2-1/2”1-1/2”568 257 3 HP/2.23 kW 8.3 7.5 3.9 3.1 eTCX-0110-SRV eHTX-0060 110 25 3”2”683 309 3HP/2.23 kW 9 8.4 4.2 3.4 eTCX-0160-SRV eHTX-0080 160 36 4”2-1/2”832 377 5 HP/3.72 kW 13.9 13.4 6.7 5.4 eTCX-0210-SRV eHTX-0090 210 48 4”3”875 396 7.5 HP/5.59 kW 21 19 9.3 7.5 eTCX-0310-SRV eHTX-0140 310 70 6”4”1109 502 7.5 HP/5.59 kW 21 18.8 9.4 7.5 eTCX-0410-SRV eHTX-0185 410 93 6”4”1233 555 10 HP/7.45 kW 25.4 24 12 9.6 eTCX-0610-SRV eHTX-0260 610 138 6”4”1859 845 20 HP/14.8 kW 50.9 46 23 18.4 eTCX-0910-SRV5 eHTX-0320 810 184 8”6”2493 1133 25 HP/18.7 kW 66 60 30 24 Side Stream and Closed Loop Configuration Flow Rate is critical to system performance. Select model based on Side Stream Flow Rates. LAKOS recommends 20% Side Stream Models eHTX Separators Flow Rates1 Diffuser/Strainer inlet4 Separator outlet System Weight Pump HP/kW2 Full Load Amperage3 US gpm m3/hr lbs kgs 208V 230V 460V 575V eTCX-0050-SRV eHTX-0025 65 15 2-1/2”1-1/4”558 267 2 HP/1.48 kW 5.6 5.1 2.52 2.1 eTCX-0080-SRV eHTX-0040 95 22 2-1/2”1-1/2”568 257 3 HP/2.23 kW 8.3 7.5 3.9 3.1 eTCX-0110-SRV eHTX-0060 140 32 3”2”683 309 3HP/2.23 kW 9 8.4 4.2 3.4 eTCX-0160-SRV eHTX-0080 210 48 4”2-1/2”832 377 5 HP/3.72 kW 13.9 13.4 6.7 5.4 eTCX-0210-SRV eHTX-0090 250 57 4”3”875 396 7.5 HP/5.59 kW 21 19 9.3 7.5 eTCX-0310-SRV eHTX-0140 365 83 6”4”1109 502 7.5 HP/5.59 kW 21 18.8 9.4 7.5 eTCX-0410-SRV eHTX-0185 450 114 6”4”1233 555 10 HP/7.45 kW 25.4 24 12 9.6 eTBX-0610-SRV eHTX-0260 610 138 6”4”1644 747 10 HP/7.45 kW 25.4 24 12 9.6 eTBX-0810-SRV5 eHTX-0320 810 184 8”6”2227 1012 15 HP/11.2 kW 41 37 18.5 14.8 NOTES: All eTCX models are available in PLUS system configurations for filtration down to .35 microns. 1 Higher flow rates available. Contact LAKOS. 2 Models 0050 and 0080 use 3500RPM. 3 Contact LAKOS for motor specific FLA. 4 Minimum suction pipe size is equivalent to system’s diffuser inlet. Pump NPSHR and piping to-and-from LAKOS Systems should be reviewed and sized accordingly. Consult LAKOS for design assistance if length of suction line is more than 25’ or has several elbows or elevation changes. 5 eTCX-0810 and eTBX-0810 units are 22 1/2 deg. low profile Since active and directed circulation of basin/sump liquid is required for effective solids removal, model selection for the LAKOS eTCX System is based upon the size of the basin or remote sump. This is best determined with these calculations: For Packaged Cooling Towers For Remote Sumps with Water Depth Greater than 3 ft** Flow Rate =Length of Basin (feet)X Width of Basin (feet)X 1 gpm/ft2 2.44 m3/hr/m2 Flow Rate =Length of Basin (feet)X Width of Basin (feet)X 1.5 gpm/ft2 3.66 m3/hr/m2 After determining the basin size using the formula to the right, refer to the flow rate column below. Select a model that has an equal or larger flow rate. Flow rates larger than those below are available. Please consult LAKOS. Basin Sweeping Model Selection Dimensions Models Dim A Dim B Dim C inches mm inches mm inches mm eTCX-0050-SRV 24 610 39-3/4 1010 38-15/16 989 eTCX-0080-SRV 29-1/2 749 45 1143 45-1/4 1149 eTCX-0110-SRV 29-1/2 749 45 1143 50-11/16 1287 eTCX-0160-SRV 29-1/2 749 45 1143 59-1/2 1511 eTCX-0210-SRV 29-1/2 749 45 1143 66-11/16 1694 eTCX-0310-SRV 31-1/2 800 45 1143 76-5/8 1946 eTCX-0410-SRV 31-1/2 800 45 1143 82 2083 eTCX/eTBX-0610-SRV 36 914 49-3/4 1264 95-1/2 2426 eTCX/eTBX-0810-SRV 46-1/2 1181 123-3/4 3143 67-1/2 1715 Dimensions are for spatial considerations only. Do not pre-plumb based on above dimensions. Contact factory for detailed dimensions. More detailed CAD drawings and CSI specifications are available at LAKOS.com. A B C D C B AA B C D 12345678 8 7 6 5 4 3 2 1 E F E F REV135140D135140SHEET 1 OF 1 eTCX-0210-SRV, TC SYSTEM, HI EFF SWEEPER eHTX-0090, 3/60/460V UNLESS OTHERWISE SPECIFIED: SCALE: 1:10WEIGHT: 875 REVDWG. NO.DSIZE TITLE: NAME DATE COMMENTS:Q.A.MFG APPR.ENG APPR.CHECKEDDRAWN FINISHMATERIALINTERPRET GEOMETRICTOLERANCING PER: DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONALANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATIONUSED ONNEXT ASSY PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF<INSERT COMPANY NAME HERE>. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF<INSERT COMPANY NAME HERE> IS PROHIBITED. eHTX Separator PE Pump 304SS Skid 8 Claude Laval Corporation, headquartered in Fresno California since 1972, is recognized worldwide for engineering, manufacturing and marketing the original centrifugal action solids from liquids separator and being the world-wide leader in cyclonic separation technology. LAKOS Separators are manufactured in the USA. 1365 North Clovis Avenue Fresno, CA 93727 www.lakos.com Tel: (559) 255-1601 info@lakos.com LS-910G (Rev. 8/19)LAKOS is a proud and contributing member of ASHRAE for over 30 years LAKOS Separators are manufactured and sold under one or more of the following U.S. Patents: 5,320,747; 5,338,341; 5,368,735; 5,425,876; 5,578,203; 5,622,545; 5,653,874; 5,894,995; 6,090,276; 6,143,175; 6,167,960; 6,202,543; 7,000,782; 7,032,760 and corresponding foreign patents, other U.S. and foreign patents pending. LAKOS® and HydroBoosters™ are trademarks of Claude Laval Corporation eTCX system components are warranted for one (1) year from date of delivery. If installed 6 months or more after ship date, warranty shall be a maximum of 18 months from ship date. eHTX separators are warranted for five (5) years from date of delivery. For detailed warranty information visit http://www.lakos.com Independent Testing LAKOS Separators have been independently tested and certified by an independent testing agency, the International Center for Water Technology (ICWT), confirming our separators’ filtration performance and capability to remove troublesome particle matter from pumped water. For over 30 years the internationally recognized ICWT/CIT Testing Laboratories have been providing independent, third party testing to a wide range of irrigation and other industries around the world. ICWT has experience with hydraulics, pumps, filters, and valves. Fluid component testing provides manufacturers, distributors and end-users with accurate performance data for applicability assessment and enable product development. ICWT was recently certified by IAPMO R&T - North America’s premier third party certification body for plumbing and mechanical products. More information about the testing agency and testing process can be found at www.californiawater.org. Limited Warranty This product series is warranted to be free of defects in material or workmanship, given the following terms: LAKOS Separator: 5 years All other components: 12 months from date of installation; if installed 6 months or more after ship date, warranty shall be a maximum of 18 months from ship date. If a fault develops, notify us, giving a complete description of the alleged malfunction. Include the model number(s), date of delivery and operating conditions of subject product(s). We will subsequently review this information and, at our option, supply you with either servicing data or shipping instruction and returned materials authorization. Upon prepaid receipt of subject product(s) at the instructed designation, we will then either repair or replace such product(s), at our option, and if determined to be a warranted defect, we will perform such necessary product repairs or replace such product(s) at our expense. This limited warranty does not cover any products, damages or injuries resulting from misuse, neglect, normal expected wear, chemically- caused corrosion, improper installation or operation contrary to factory recommendation. Nor does it cover equipment that has been modified, tampered with or altered without authorization. No other extended liabilities are stated or implied and this warranty in no event covers incidental or consequential damages, injuries or costs resulting from any such defective product(s). EFS Valve shown with purge controller Electric Fail-Safe Valve Automatically Closes Purge Valve in Case of Power Failure EFS Features and Benefits: • EFS closes purge valve in case of power failure • Purges solids automatically – eliminating manual purging • Visual indicator on EFS provides easy-to-read current valve position • Manual override for quick purge situations • EFS features an electronic circuit that adjusts motor speed to keep cycle time constant, maintaining consistent purge durations • Can be installed in combination with Solids Recovery Vessel (SRV-816 or SRV-833) for short-term conditions that require direct purging • Actuator housing made of V0 self-extinguish material for fire safety • EFS features a torque limiter circuit that protects motor from overcurrent or overtorque conditions Contact LAKOS for EFS installation guide with more detailed specifications. Specifications: Voltage: 12V DC, 24V DC and 100-240V AC Frequency: 50/60Hz Power Draw: 30-48 VA Current Draw: 0.3-0.2 A 75% Duty Rated Valve Open-Close Time: 8 seconds from 0 to 90 degrees. Fail-Safe Delay: EFS Valve starts closing 5 seconds after power loss Housing: V0 self-extinguish class techno-polymer, water-tight Protection Level: NEMA 4/4X IP65 IP67 Certifications: CE UL Cover Type: UL 50 Ambient Temperature Range: -4 F to 131 F Auxiliary Contact Rating: 1A @ 30VDC/250VAC RESISTIVE Protection Against Electrical Shock: Class I Cover Type: UL 50 Recommended Battery Check: Once per year, expected life time is 12-15 years Fail-Safe Batteries: Rechargeable Nickel-Metal- Hydride battery pack that provides 400 charge/ discharge cycles. The batteries are automatically charged when the supply is connected Models: 1365 N. Clovis Avenue • Fresno, California 93727 USATelephone: (559) 255-1601 • Fax: (559) 255-8093www.lakos.com • info@lakos.comLS-913A (Rev. 12/13) LAKOS® is a trademark of Claude Laval Corporation LAKOS is an active member of the U.S. Green Building Council LAKOS is a proud and contributing member of ASHRAE for over 30 years Models Valve Diameter inches mm EFS-07 3/4”19.05 EFS-15 1-1/2”38.1 Purge controller is required and included as part of valve kit. SEPARATOR INLET EFS connected toLAKOS controller SEPARATOROUTLET EFS Separator purge EFS and LAKOS Controller automatically purge separated solids from Separator’s collection chamber at pre-determined time intervals – eliminating manual purging. EFS Installation: Smartart TMLAKOS Stop/Start/Auto with www.franklin-controls.com | 1.800.962.3787 1 3Ø, 200~460VAC, 1–95A Automation system ready Standard Features: ƒDoor mounted Hand-Off-Auto switch ƒManual purge button on enclosure door ƒBuilt, sized and set for your pump Designed for ease of integration with automation systems ƒReduces Installation Costs ƒComprehensive inputs/outputs for energy management systems ƒAuto-run input for remote control ƒ Selectable normally open dry contact or wide-range voltage input (accepts 10-130VAC/DC) Superior motor and pump protection ƒ protection ƒ Electronic overload protection including locked rotor, cycle fault, current phase imbalance and maximum time to start ƒ FLA out of calibration indication--ensures installer sets overload correctly based on calculated motor size ƒ Underpower (dry run) protection ƒ Ground fault protection (UL 1053 certified) ƒ Over/Under voltage protection ƒ Voltage phase loss/imbalance protection ƒ Reverse phase protection MCP Disconnect Included ƒMotor circuit protection disconnect provides short circuit protection ƒHigh interrupting ratings for maximum electrical system compatibility ƒNo fuses required ƒLockable handle for safety Fault logging retains critical information ƒ Last 15 fault types are recorded (e.g. underpower, overload, voltage/current loss/unbalance, etc.) ƒ Fault counter: stores how many times each fault type has occurred (Up to 255) ƒ Logs changes to parameter settings (e.g. overload, OV/ UV, underpower) ƒ All power condition values are displayed UL Type 4X Fiberglass Enclosure ƒ Lockable enclosure ƒ Light weight ƒ Corrosion resistant Standard Multi-tap Control Power Transformer ƒ Accepts 200-480VAC ƒ Integrated secondary protection ƒ No fuses required Optional BACnet or Modbus Communications ƒNative RS-485 76800 BPS for high performance ƒAdditional programmable digital input. Additional analog input, selectable between 0-10V, 4-20 mA, or 10K thermistor ƒIncludes power metering display with programmable parameters Optional Features: ƒPurge timer with door mounted On-Off switch ƒ600V and custom models available ƒTower switching timer with door mounted On-Off switch LAKOS SmartStarterwithMotor ProtectionSmartart TMLKS NEMA Sized Smartart TM Smartart TMLAKOS Stop/Start/Auto with www.franklin-controls.com | 1.800.962.3787 3 LAKOS Pump Starter Wiring Schematics *Standard product wiring diagram shown. Assembled product wiring may vary depending on option selected  UL Type 4X Enclosure Dimensions 1 1 2 2 3 3 4 4 A A B B 100AF LKS Starter Dimensions 10MTG. 21 1/4MTG. 11 1/8 12 7/8 17 3/4 20 1/2 22 1 1 2 2 3 3 4 4 A A B B R. LAUW CHECKED BY R. LAUW UNLESS OTHERWISESPECIFIEDDIMENSIONS ARE IN INCHES B SIZE 1 OF 2 1 DATE PART NO. FRANKLIN CONTROL SYSTEMS DRAWN BY REV SHEET PROJECT 40AF LKS Starter Dimensions 12 MTG. 16 3/4MTG.16 1/2 17 1/2 15 7/8 9 1/410 7/8 3/8 TYP. 4 Specifications Starter Type LKS - Lakos Smartstarter Combination - Includes MCP Disconnect NEMA Type 4X, Fiberglass Enclosed User Interface Setting Adjustments Internal Hand-Off-Auto Switch Door mounted Standard Control Operations Inputs Voltage Auto Run Apply 10 - 130VAC/DC to energize Shutdown Apply 10 - 130VAC/DC to energize Dry Auto Run N.O. dry contact closure Actuator Switch N.O. dry contact closure Outputs Run Status N.O., 0.3A@125VAC; 1A@24VAC Fault relay N.O., 0.3A@125VAC; 1A@24VAC Actuator Motor 120VAC, 0.25A max Operational Overload Type Electronic, I2t trip curve Power fail modes Restart last mode, no delay (default) Restart in “off” if power failure lasts longer than 2 seconds. Restart in last mode if power failure is less than 2 seconds. Restart in Off mode On/Off Time Delay Programmable, selectable from 0.1 to 99 seconds Environmental Surrounding Air Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing Motor / Pump Protection Programmable Range Current Setting Range Differs per model Trip Class Adjustable: Class 5 - 30 Voltage Phase Unbalance On/Off: 1-50% Voltage Phase Loss Always On: 1-50% Cycle Fault On/Off: Trips if the amount of contactor closures exceed a rate > 20 closures per minute. Under Power (Dry-Run)On/OFF: 0-99% of measured electrical input Reverse Phase (Phase Sequence)On/Off: Trips within 0.1 seconds upon reverse phase detection Ground Fault On/Off: 1.0-95A, UL1053 Certified Over/Under Voltage On/Off: 5-25% Locked Rotor/Stall- On/Off: Trip within 0.5 seconds @ 300% FLA Current Phase Unbalance- On/Off: 5-50% Max Time to Start- On/Off:Trips if the motor takes more than 10 seconds to start FLA Out-of-Calibration- On/Off: Trips if the FLA setting is determined to be incorrect (set too high) Smartart TM