HomeMy WebLinkAbout221005-03-0 - PVC Pipe Fittings Primer Cement - reviewed by Aztech - AN. . . . . . . . . . . . . . . . . . . . . . . . . . . . D/E/F Services Group, LTD 1171 Voluntown Road Griswold, CT 06351 Phone: (860) 376-4896 Fax: (860) 376-1213 Submittal Transmittal TO: The Maggiore Companies 13 Wheeling Ave. Worburn, MA 01801 Date: 9/26/2019 Project # F29166 - F29166 Oxoboxo Submittal # 008 ATTN: Gifford Perry RE: PVC Pipe, Fittings, Primer, Cement We are sending you the following:  Attached  Under Separate Cover Via:  1st Class Mail  Overnight  Facsimile  Pick-Up/Hand Deliver Copies Spec No. Description 1 221005 PVC Pipe, Fittings, Primer, Cement Remarks: Please see the attached submittal for approval. Received By: _________________________________ Date: ________________________ Signed: _______________________________ Title: _________________________________ Copy to: ___________________  Recipient’s Copy  Sign & Return  File Copy SUBMITTAL FOR CHARLOTTE PIPE® PVC SCHEDULE 40 SOLID WALL PIPE AND PVC DWV FITTING SYSTEM Charlotte Pipe and Charlotte Pipe and Foundry Company are registered trademarks of Charlotte Pipe and Foundry Company. FO-SUB-PVC-DWV (5-28-14) Date: ________________ Job Name: ______________________________ Location: _______________________________ Engineer: _______________________________ Contractor: ______________________________ Scope: This specification covers PVC Schedule 40 solid wall pipe and PVC DWV fittings used in sanitary drain, waste and vent (DWV), sewer and storm drainage applications. This system is intended for use in non-pressure applications where the operating temperature will not exceed 140° F. Specification: Pipe shall be manufactured from virgin rigid PVC (polyvinyl chrloride) vinyl compounds with a cell class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (IPS) conforming to ASTM D 1785 and ASTM D 2665. Injection molded PVC DWV fittings shall conform to ASTM D 2665. Fabricated PVC DWV fittings shall conform to ASTM F 1866. All pipe and fittings shall be manufactured in the United States. All systems shall utilize a separate waste and vent system. Pipe and fittings shall conform to NSF International Standard 14. Installation: Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all applicable plumbing, fire, and building code requirements. Buried pipe shall be installed in accordance with ASTM D 2321 and ASTM F 1668. Solvent cement joints shall be made in a two-step process with primer conforming to ASTM F 656 and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire-stopping materials, thread sealant, plasticized-vinyl products or other aggressive chemical agents not compatible with PVC compounds. The system shall be hydrostatically tested after installation. WARNING! Never test with or transport/store compressed air or gas in PVC pipe or fittings. Doing so can result in explosive failures and cause severe injury or death. Referenced Standards: ASTM D 1784: Rigid Vinyl CompoundsASTM D 1785: PVC Plastic Pipe, Schedule 40ASTM D 2665: PVC Drain, Waste and Vent Pipe and FittingsASTM D 2564: Solvent Cements for PVC Pipe and FittingsASTM D 2321: Underground Installation of Thermoplastic Pipe (non-pressure applications)ASTM F 656: Primers for PVC Pipe and FittingsASTM F 1668: Procedures for Buried Plastic PipeASTM F 1866: Fabricated PVC DWV FittingsNSF Standard 14: Plastic Piping Components and Related Materials Not all fitting patterns shown Combination Wye & Eighth Bend Closet FlangeP-Trap Double Sanitary Tee Eighth BendQuarter BendCoupling Cleanout Tee w/Plug PVC Schedule 40 DWV Pipe Charlotte Pipe and Foundry Company • P.O. Box 35430 Charlotte, NC 28235 • (800) 438-6091 • www.charlottepipe.com PVC Schedule 40 DWV Pipe PVC 7100* 11⁄4”x10’ 03945 2120’ 1.660 .140 42.4 PVC 7100* 11⁄4”x20’ 03946 4240’ 1.660 .140 42.4 PVC 7112* 11⁄2”x10’ 03947 1720’ 1.900 .145 50.7 PVC 7112* 11⁄2”x20’ 03948 3440’ 1.900 .145 50.7 PVC 7200* 2”x10’ 03949 990’ 2.375 .154 68.1 PVC 7200* 2”x20’ 03950 1980’ 2.375 .154 68.1 PVC 7300* 3”x10’ 03951 1040’ 3.500 .216 141.2 PVC 7300* 3”x20’ 03952 920’ 3.500 .216 141.2 PVC 7400 † 4”x10’ 03953 600’ 4.500 .237 201.2 PVC 7400 † 4”x20’ 03954 1200’ 4.500 .237 201.2 PVC 7500 † 5”x20’ 04837 760’ 5.563 .258 272.5 PVC 7600 † 6”x10’ 03955 280’ 6.625 .280 353.7 PVC 7600 † 6”x20’ 03956 560’ 6.625 .280 353.7 PVC 7800 † 8”x10’ 13087 180’ 8.625 .322 532.3 PVC 7800 † 8”x20’ 03958 360’ 8.625 .322 532.3 PVC 7910 † 10”x20’ 03959 220’ 10.750 .365 754.7 PVC 7912 † 12”x20’ 03961 120’ 12.750 .406 997.9 PVC 7914 † 14”x20’ 04862 60’ 14.000 .437 1180.1 PVC 7916 † 16”x20’ 04918 60’ 16.000 .500 1543.1 PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665 PVC SCHEDULE 40 (WHITE) PLAIN END PVC 1120 ASTM D 2665 PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL WT. PER 100 FT. 611942- SKID (IN.) (IN.) (LBS.) * Dual Marked ASTM D 1785 & ASTM D 2665.† Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480. PURPLE PRIMER CLEANER Page 1 of 2 TECHNICAL SPECIFICATION: Oatey Purple Primer Cleaner is a purple-tinted primer/cleaner recommended for use with PVC and CPVC pipe and fittings. Purple Primer Cleaner is formulated to remove dirt and oil from the surface of the piping, as well as soften the piping in preparation for solvent welding. Purple pigment provides verification that primer has been applied to the pipe surface. This product is compliant with California South Coast Air Quality Management District (SCAQMD) Rule 1168 and Ozone Transport Commission (OTC) regulations for Volatile Organic Compound emission levels. Note: This product is not for use in a system using or being tested by compressed air or gases. PHYSICAL/CHEMICAL PROPERTIES Appearance Purple Liquid Density 6.78 ± 0.2 lbs/gallon Shelf Life 3 years from manufacture date Maximum VOC per SCAQMD 1168/316A or BAAQMD Method 40: 550 g/L INGREDIENTS (CAS Number) Acetone (67-64-1) Cyclohexanone (108-94-1) Methyl Ethyl Ketone (78-93-1) Tetrahydrofuran (109-99-9) Red Dye (4477-79-6) Violet Dye (81-48-1) PRODUCT NUMBER SIZE PACK CARTON WEIGHT 30780 4 oz. 24 8 lbs. 30783 8 oz. 24 14 lbs. 30796 16 oz 24 25 lbs. 30806 32 oz. 12 24 lbs. 30768 Gallon 6 46 lbs. Visit www.oatey.com for updates 1/2010 Visit www.oatey.com for updates PURPLE PRIMER CLEANER Page 2 of 2 PRECAUTIONS Read all information carefully before using this product. DANGER: EXTREMELY FLAMMABLE. VAPORS MAY CAUSE FLASH FIRES. MAY IRRITATE EYES AND SKIN. VAPOR HARMFUL. MAY IRRITATE RESPIRATORY TRACT AND CAUSE CENTRAL NERVOUS SYSTEM DEPRESSION. HARMFUL OR FATAL IF SWALLOWED. May cause irritation to eyes, skin, and nose, throat, and respiratory tract. May cause coughing, sore throat, difficulty breathing, headache, dizziness, nausea. Long term repeated overexposures to solvents may cause damage to the brain, nervous system, reproductive system, respiratory system, mucous membranes, liver, and kidneys. KEEP OUT OF REACH OF CHILDREN. FIRST AID: If swallowed, DO NOT INDUCE VOMITING. Drink water and call a doctor or poison control center immediately. This product may be aspirated into the lungs and cause chemical pneumonitis, a potentially fatal condition. If contact with eyes, flush with water for 15 minutes and seek medical attention if irritation persists. If contact with skin, wash with soap and water. If inhaled and ill feelings develop, get fresh air and obtain medical attention if ill feelings persist. FOR EMERGENCY FIRST AID INSTRUCTIONS CALL 1-877-740-5015. FIRE: Use dry chemical, foam, or carbon dioxide extinguisher. Water spray may be applied to reduce potential vapors or for cooling. Burning liquid extinguished with water will float and may re-ignite on surface of water. SPILLS: Remove all sources of ignition and ventilate area. Personnel cleaning up the spill should wear appropriate personal protective equipment, including respirators if vapor concentrations are high. Soak up spill with absorbent material. Put absorbent material in covered, labeled metal containers. Dispose of in accordance with local regulations. A fire or explosion may result if dry granular calcium hypochlorite is used to disinfect plastic piping systems and is exposed to organic vapors found in solvent cements, cleaners or primers. Do not disinfect piping system with dry granules. Do not store dry granular calcium hypochlorite near solvent cements, cleaners or primers. DO NOT REUSE EMPTY CONTAINER. KEEP OUT OF REACH OF CHILDREN. Refer to material safety data sheet for more information. 1/2010 DIRECTIONS FOR USE Read all directions carefully before using this product. • Do not breathe vapors. Use only in well ventilated area. If forced air ventilation is used, be sure it does not cause a fire hazard from solvent vapors. If adequate ventilation cannot be provided, wear a NIOSH-approved respirator for organic solvents. • Do not use or store near heat, sparks, or flames. Do not smoke, eat or drink when using. Do not take internally. Vapors may accumulate in low places and may ignite explosively. • Store and use at temperatures between -15ºF and 110ºF. At temperatures outside of this range, special care must be taken to prepare good joints and prevent exposures to solvents. • Stir or shake before using; if jelly-like, don’t use. Keep container closed when not in use. • Avoid eye and skin contact - wear safety glasses with side shields and wear rubber gloves. • HANDLE WITH CARE! WILL STAIN MOST MATERIALS AND SURFACES. • Do not thin. • Verify with local building codes that the use of Primer Cleaner is permitted. 1. Square pipe ends and remove all burrs and dirt. 2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If the pipe bottoms, it should be snug. 3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a natural bristle brush or roller. 4. Apply thoroughly to outside surface of the pipe to the depth of the fitting and inside of the fitting socket. 5. Use appropriate solvent cement for the pipe being joined. DO NOT TEST WITH AIR. This product is not for use with caustic or acidic chemical solutions. Consult Oatey Technical Department for more information. Before purchase and use of a product, review the product application and be certain the product, installation and use will be in compliance with any applicable codes and regulations. Technical Specification Medium Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 1 of 3 Description • Medium-bodied clear cement for use on all schedules and classes of PVC pipe and fittings up to 6" diameter with interference fit. • Lo-V.O.C. Solvent Cement meets California South Coast Air Quality Management District (SCAQMD) 1168/316A or BAAQMD Method 40 and various environmental requirements. • Recommended for potable water, pressure pipe, conduit and DWV. • Recommended application temperature 40°F to 110°F / 4°C to 43°C. • Meets ASTM D2564. Listings NSF Standard 61 for PW, DWV and Sewer Waste IAPMO Listed Maximum VOC per SCAQMD 1168/316A or BAAQMD Method 40: 510 g/L INGREDIENTS (CAS Number) Acetone (67-64-1), Amorphous Silica (112945-52-5), Cyclohexanone (108-94-4), Methyl Ethyl Ketone (78-93-3), PVC Resin (9002-86-2), Tetrahydrofuran (109-99-9) MSDS Number: 1101E Product Number Size Qty Wgt Product Number Size Qty Wgt 31017 4 oz. 24 27 lbs. 310173 4 oz. 72 9 lbs. 31018 8 oz. 24 28 lbs. 310183 8 oz. 36 15 lbs. 31019 16 oz. 24 50 lbs. 310193 16 oz. 10 28 lbs. 31020 32 oz. 12 27 lbs. 310203 32 oz. 6 27 lbs. 31021 Gallon 6 50 lbs. Technical Specification Medium Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 2 of 3 CHEMICAL PROPERTIES PHYSICAL PROPERTIES Appearance Viscosity Density Shelf Life Clear Liquid Min. 500 cps @73° F ± 2° F 7.74 ± 0.2 lbs/gallon 3 years from manufacture date Lap Shear Strength 2 hours 16 hours 72 hours Set Up Time 30° F to 50° F 50° F to 70° F 70° F to 90° F (min. ASTM Standards) 250 psi 500 psi 900 psi 5 – 6 minutes 3 – 4 minutes 1 – 2 minutes Precautions Read all information carefully before using this product. DANGER!: CAUSES SERIOUS EYE IRRITATION. HARMFUL IF INHALED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE RESPIRATORY IRRITATION. REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING. Long term overexposure to solvents may cause damage to the brain, nervous system, reproductive system, respiratory system, mucous membranes, liver and kidneys. Contains a chemical classified by the US EPA as a suspected possible carcinogen. KEEP OUT OF REACH OF CHILDREN. PRECAUTIONS: Avoid breathing vapors. Use only outdoors or in a well-ventilated area. Use explosion- proof electrical/ventilating equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Wear a NIOSH-approved respirator for organic solvents. Keep away from heat/sparks/open flames/hot surfaces. No smoking. Vapors may accumulate in low places and may ignite explosively. Keep container tightly closed and cool. Wear protective gloves and eye protection. Wash thoroughly after handling. Do not eat or drink while using this product. EMERGENCY/FIRST AID: CALL 1-877-740-5015 FOR INSTRUCTIONS. IF SWALLOWED: Immediately call a POISON CENTER/doctor. Do NOT induce vomiting. Rinse mouth. This product may be aspirated into the lungs and cause chemical pneumonitis, a potentially fatal condition. If IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention. If ON SKIN: Rinse skin with water/shower. Take off immediately all contaminated clothing. If INHALED: Remove person to fresh air and keep comfortable for breathing. Call POISON CENTER/doctor if you feel unwell. If medical advice is needed, have product container or label at hand. FIRE: Use dry chemical, foam, or carbon dioxide extinguisher. Water spray may be applied to reduce potential vapors or for cooling. Burning liquid extinguished with water will _oat and may re-ignite on surface of water. SPILLS: Remove all sources of ignition and ventilate area. Personnel cleaning up the spill should wear appropriate personal protective equipment, including respirators if vapor concentrations are high. Soak up spill with absorbent material. Put absorbent material in covered, labeled metal containers. Dispose of contents/ container in accordance with local regulations. Store in a well-ventilated space. Store locked up. Technical Specification Medium Clear PVC Cement Oatey Co. 4700 West 160 th St. Cleveland, OH 44135 Phone: 1-800-321-9532 Phone: 1-800-321-9535 Visit www.oatey.com for Update Page 3 of 3 Directions for Use Store and use at temperatures between 40°F and 110°F. At temperatures outside of this range, special care must be taken to prepare good joints and prevent exposure to solvents. Stir or shake before using; if jelly-like, don’t use. Do not thin. 1. Cut pipe ends square, chamfer and clean pipe ends. 2. Check dry fit of pipe and fitting. Pipe should easily go 1/3 of the way into the fitting. If pipe bottoms, it should be snug. 3. Use a suitable applicator at least 1/2 the size of the pipe diameter. For larger size pipe systems use a natural bristle brush or roller. 4. Clean pipe and fitting with a listed primer. 5. Apply liberal coat of cement to pipe to the depth of the socket, leave no uncoated surface. 6. Apply a thin coat of cement to inside of fitting, avoid puddling of cement. Puddling can cause weakening and premature failure of pipe or fitting. Apply a second coat of cement to the pipe. 7. Assemble parts QUICKLY. Cement must be fluid. If cement surface has dried, recoat both parts. 8. Push pipe FULLY into fitting using a ¼ turning motion until pipe bottoms. 9. Hold pipe and fitting together for 30 seconds to prevent pipe push-out - longer at low temperatures. Wipe off excess. 10. Allow 15 minutes for good handling strength and 2 hours cure time at temperatures above 60°F before pressure testing up to 180 psi. Longer cure times may be required at temperatures below 60°F or with pipe above 3". DO NOT TEST WITH AIR. Revision Date: 3/15/2013