Loading...
HomeMy WebLinkAbout210500-01-0 - Oxoboxo-Electrical Equipment Panelboards Loadcenters-Azt MAGGIORE CONSTRUCTION CORP. 13 Wheeling Avenue, Woburn, MA 01801 Phone 781.935.6100 FAX 781.933.8044 SUBMITTAL ACTION SHEET Oxoboxo Lofts 40 Pink Row Uncasville, CT General Contractor:Architect: Maggiore Construction Corp.Paul B Bailey Architects 13 Wheeling Ave.110 Audubon Street Woburn, MA 01801 New Haven, CT 06510 Job No.: 1214 Job No.: 16-063 Prepared By:Maggiore Construction Corp. Form of Submittal: Samples Cut Sheets Schedule Shop Drawings Other Description:Equipment Panel Boards Group Metering Safety switches Loadcenters & Circuit Breakers Manufacturer:Eaton Other/Notes:Does not include circuits for added ground water remediation in Building M, please review and add as needed. Does not include addendum #08 changes Received By MCC:11/27/2019 Received By Owner: Reviewed:Comments: Approved Approved as Noted Rejected Revise and Re-submit Compliance Equal Submitted For Approval By: Gifford Perry - Senior Project Manager Approved By: Date:11/27/2019 Date: Horton Electrical Services,LLC Canton Business Park 97 River Road Canton, Connecticut 06019 (860)693.6388 (860)693.6517 FAXLicense # CT E-192436 Date:11/25/2019 Job:19-01-021 OXOBOXO Phase 1 Letter of Transmittal Transmittal #:4To:Gifford Perry Subject:Submittal-26 24 16 Panelboards Samples Change order Shop drawings Under separate cover via the following items:AttachedWE ARE SENDING YOU Submittal Prints Plans Copy of letter Spec. Section DescriptionNo.DateCopiesDocument Type 1 11/25/19 26 2416-1 Rev 0 PanelboardsSubmittal Other PRINTS RETURNED AFTER LOAN TO USFOR BIDS DUE For review and comment Return ___ corrected printsReturned for corrections Submit ___ copies for distributionApproved as noted For approval Resubmit ___ copies for approvalApproved as submitted THESE ARE TRANSMITTED as checked below: Remarks: For your use As requested Copy To:Gerry Campion (Horton Electrical) Signature:From:Marilyn Horton (Horton Electrical Services, LL) If enclosures are not as noted, kindly notify us at once. Page 1 of 1 OXOBOXO LOFTS 42 Pink Row Uncasville, CT 11-25-19 GENERAL CONTRACTOR: Maggiore Construction Corporation 13 Wheeling Avenue Woburn, MA 01801 ELECTRICAL CONTRACTOR: Horton Electrical Services 97 River Road Canton, CT 06019 860‐693‐6388 26 24 16 Panelboards CIVIL ENGINEER: BSC Group 300 Winding Brook Drive Glastonbury, CT 06033 STRUCTURAL ENGINEER: Morrissey Engineering, LLC 58 Essex Street Deep River, CT. 06417 ARCHITECT: Paul B. Bailey Architect, LLC. 110 Audubon Street New Haven, CT 06510 MECHANICAL/ELECTRICAL ENGINEER: Aztech Engineer, Inc. 901 Wethersfield Avenue Hartford, CT 06114 Detail Bill of Material Page 1 of 3 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Item No. Qty Product Description 1 Panelboards 47 Circuits, 400A, Fully Rated, 208Y/120V 3Ph 4W, Copper Bus, 10k AIC, 400A, DK 3P Main Breaker[Top Fed], Surface Mounted Catalog No P3A400BT54CH01 Designation HPB Qty List of Materials 1 400A, DK 3P Main Breaker: DK3400W 25 1P BAB Branch Provision Only: PROVBAB1 4 20A, 1P BAB Branch Breaker: BAB1020 1 20A, 2P BAB Branch Breaker: BAB2020 2 100A, 2P BAB Branch Breaker: BAB2100 1 20A, 3P BAB-H Branch Breaker: BAB3020H 1 80A, 3P BAB-H Branch Breaker, w/ Shunt Trip: BAB3080HS 2 225A, 3P EDB Branch Breaker: EDB3225 1 Copper Main Bus, 400 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2necNeu 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2090R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2090S Item No. Qty Product Description 1 Panelboards 42 Circuits, 225A, Fully Rated, 120/240V 1Ph 3W, Copper Bus, 10k AIC, 200A, ED Main Breaker[Bottom Fed], Surface Mounted Catalog No P1C225BB42CH01 Designation BLDG L ADDED PANEL Qty List of Materials 1 200A, ED Main Breaker: EDB3200 42 20A, 1P BAB Branch Breaker: BAB1020 1 Copper Main Bus, 225 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2_1a 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2048R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2048S Item No. Qty Product Description 1 Panelboards 42 Circuits, 225A, Fully Rated, 208Y/120V 3Ph 4W, Copper Bus, 10k AIC, 225A, 3P EDB Main Breaker[Bottom Fed], Surface Mounted Catalog No P1A225BB42CH01 Designation HPB1 Qty List of Materials 1 225A, 3P EDB Main Breaker: EDB3225 4 50A, 2P BAB Branch Breaker: BAB2050 1 30A, 2P BAB Branch Breaker: BAB2030 1 20A, 2P BAB Branch Breaker: BAB2020 22 20A, 1P BAB Branch Breaker: BAB1020 Detail Bill of Material Page 2 of 3 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Qty List of Materials 4 2P BAB Branch Provision Only: PROVBAB2 1 Copper Main Bus, 225 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2_1a 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2048R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2048S Item No. Qty Product Description 1 Panelboards 42 Circuits, 125A, Fully Rated, 208Y/120V 3Ph 4W, Copper Bus, 10k AIC, 100A, 3P BAB-H Main Breaker[Bottom Fed], Flush Mounted Catalog No P1A225BB42CH01 Designation HPE Qty List of Materials 1 100A, 3P BAB-H Main Breaker: BAB3100H 15 20A, 1P BAB Branch Breaker: BAB1020 11 2P BAB Branch Provision Only: PROVBAB2 2 20A, 2P BAB Branch Breaker: BAB2020 1 1P BAB Branch Provision Only: PROVBAB1 1 Copper Main Bus, 225 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2_1a 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2042R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2042F Item No. Qty Product Description 1 Panelboards 60 Circuits, 225A, Fully Rated, 208Y/120V 3Ph 4W, Copper Bus, 10k AIC, 100A, 3P BAB-H Main Breaker[Bottom Fed], Surface Mounted Catalog No P1A225BB60CH01 Designation HPF Qty List of Materials 1 100A, 3P BAB-H Main Breaker: BAB3100H 1 20A, 2P BAB Branch Breaker: BAB2020 2 80A, 3P BAB-H Branch Breaker: BAB3080H 2 50A, 3P BAB-H Branch Breaker: BAB3050H 1 40A, 3P BAB-H Branch Breaker, w/ Shunt Trip: BAB3040HS 3 2P BAB Branch Provision Only: PROVBAB2 3 20A, 3P BAB-H Branch Breaker: BAB3020H 9 20A, 1P BAB Branch Breaker: BAB1020 18 1P BAB Branch Provision Only: PROVBAB1 1 Copper Main Bus, 225 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2necNeu 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2060R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2060S Detail Bill of Material Page 3 of 3 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Item No. Qty Product Description 1 Panelboards 42 Circuits, 125A, Fully Rated, 208Y/120V 3Ph 4W, Copper Bus, 10k AIC, 100A, 3P BAB-H Main Breaker[Bottom Fed], Flush Mounted Catalog No P1A225BB42CH01 Designation HPH1 Qty List of Materials 1 100A, 3P BAB-H Main Breaker: BAB3100H 21 20A, 1P BAB Branch Breaker: BAB1020 6 20A, 2P BAB Branch Breaker: BAB2020 4 2P BAB Branch Provision Only: PROVBAB2 1 1P BAB Branch Provision Only: PROVBAB1 1 Copper Main Bus, 225 Amps: CN_bus_mat_cu 1 Std. Bolted Al Ground Bar (Al/Cu Cable): CN_gndbus_2_1a 1 Panel Nameplate - White with Black Letters: CN_trm_np_M_WB 1 Circuit Directory - Metal Frame with Plastic Cover: CN_direct_M 1 Type 1 Enclosure: EZB2042R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2042F Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction thereof for the time the shipment is delayed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 Main Breaker 400ADK3400W, Vert Mtd. Neutral BAB2100 BAB2100 BAB3080HS PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 BAB1020 BAB1020 BAB1020 BAB1020 BAB2020 BAB3020H PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 EDB3225 225A EDB3225 225A Bus Cover 6X General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:400A Copper Neutral Rating:400A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Top Cable Entry Main Terminals:Mechanical -(1) 2/0-500 kcmil (Cu/Al) Neutral Terminals:Mechanical -(2) #4-500 kcmil (Cu/Al) Box Catalog No.:EZB2090R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2090S) Surface Mounted Box Dimensions:90.00" [2286.0mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 4" [101.6mm] Right = 4" [101.6mm] Panel ID Nameplate:(1) HPB Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) UL Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 344 Branch Devices Qty Poles Trip Frame Amps kAIC 2 3 225 EDB 225 10 1 3 80 BAB 100 10 1 3 20 BAB 100 10 2 2 100 BAB 100 10 1 2 20 BAB 100 10 4 1 20 BAB 100 10 25 1 PROVBAB1 Main Devices Qty Poles Trip Frame Amps kAIC 1 3 400 DK 400 10 Device Modifications: Ref #Description BAB Shunt Trip Shunt Trip Included Ckt #:5 Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS HPB PRL3a Customer Approval 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Blank Cover 3 inches BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 Main Breaker 200A EDB3200, Vert Mtd. General Information (Section 1 of 1) Service Voltage:120/240V 1Ph 3W Enclosure:Type 1 Bus Rating & Type:225A Copper Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Bottom Cable Entry -A & C Phase Connection Main Terminals:Mechanical -(1) #4-4/0 (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2048R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2048S) Surface Mounted Box Dimensions:48.00" [1219.2mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) BLDG L ADDED PANEL Type:Plastic, adhesive-backed (2) 120/240V 1Ph 3W Color:White with Black Letters (3) UL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 109 Weight -lbs (Est.) = 150 Branch Devices Qty Poles Trip Frame Amps kAIC 42 1 20 BAB 100 10 Main Devices Qty Poles Trip Frame Amps kAIC 1 3 200 EDB 225 10 Device Modifications: Ref #Description Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 CHRISTOPHER A HAWKINS 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS BLDG L ADDED PANEL PRL1a Customer Approval 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Blank Cover 3 inches BAB2050 BAB2050 BAB2050 BAB2050 BAB2030 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 PROVBAB2 PROVBAB2 BAB1020 BAB1020 PROVBAB2 BAB1020 BAB1020 BAB1020 PROVBAB2 BAB1020 BAB1020 BAB2020 BAB1020 BAB1020 Main Breaker 225A EDB3225, Vert Mtd. General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:225A Copper Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Bottom Cable Entry Main Terminals:Mechanical -(1) #4-4/0 (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2048R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2048S) Surface Mounted Box Dimensions:48.00" [1219.2mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) HPB1 Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) UL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 109 Weight -lbs (Est.) = 140 Branch Devices Qty Poles Trip Frame Amps kAIC 4 2 50 BAB 100 10 1 2 30 BAB 100 10 1 2 20 BAB 100 10 22 1 20 BAB 100 10 4 2 PROVBAB2 Main Devices Qty Poles Trip Frame Amps kAIC 1 3 225 EDB 225 10 Device Modifications: Ref #Description Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS HPB1 PRL1a Customer Approval 1 of 1 PROV 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Blank Cover 1 inches BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB2020PROVBAB2 PROVBAB2 BAB1020PROVBAB2 BAB2020 BAB1020 Bus Support PROVBAB2 PROVBAB2 PROVBAB2PROVBAB2 PROVBAB2PROVBAB2 PROVBAB2PROVBAB2 BAB1020 Main Breaker 100A BAB3100H General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:225A Copper Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Bottom Cable Entry Main Terminals:Mechanical -(1) #8-1/0 (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2042R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2042F) Flush Mounted Box Dimensions:42.00" [1066.8mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) HPE Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) UL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 67 Weight -lbs (Est.) = 96 Branch Devices Qty Poles Trip Frame Amps kAIC 15 1 20 BAB 100 10 11 2 PROVBAB2 2 2 20 BAB 100 10 1 1 PROV Main Devices Qty Poles Trip Frame Amps kAIC 1 3 100 BAB-H 100 10 Device Modifications: Ref #Description Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS HPE PRL1a Customer Approval 1 of 1 PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV PROV 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Blank Cover 7 inches BAB3080H BAB3080H BAB3050H BAB3050H BAB3040HS PROVBAB2 PROVBAB2 BAB3020H BAB3020H BAB3020H BAB1020 PROVBAB2 BAB1020 BAB1020 BAB1020 BAB1020 Bus Support Main Breaker 100A BAB3100H BAB1020 BAB1020 BAB1020 BAB1020 BAB2020 General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:225A Copper Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Bottom Cable Entry Main Terminals:Mechanical -(1) #8-1/0 (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2060R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2060S) Surface Mounted Box Dimensions:60.00" [1524.0mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) HPF Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) UL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 117 Weight -lbs (Est.) = 108 Branch Devices Qty Poles Trip Frame Amps kAIC 2 3 80 BAB 100 10 2 3 50 BAB 100 10 1 3 40 BAB 100 10 3 2 PROVBAB2 3 3 20 BAB 100 10 9 1 20 BAB 100 10 1 2 20 BAB 100 10 18 1 PROV Main Devices Qty Poles Trip Frame Amps kAIC 1 3 100 BAB-H 100 10 Device Modifications: Ref #Description BAB Shunt Trip Shunt Trip Included Ckt #:13 Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS HPF PRL1a Customer Approval 1 of 1 PROV 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Blank Cover 1 inches BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB2020BAB2020 Bus Support PROVBAB2 PROVBAB2PROVBAB2 BAB2020 PROVBAB2 BAB2020 BAB2020 BAB1020 BAB2020 Main Breaker 100A BAB3100H General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:225A Copper Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:10k A.I.C. Fully Rated Main Device Type:Main Breaker -Bottom Cable Entry Main Terminals:Mechanical -(1) #8-1/0 (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2042R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2042F) Flush Mounted Box Dimensions:42.00" [1066.8mm]H x 20.00" [508.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) HPH1 Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) UL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Metal Frame with Plastic Cover Main Circuit Breaker Trip Type: Thermal-Magnetic. Heat Loss -Watts (Est.) = 67 Weight -lbs (Est.) = 99 Branch Devices Qty Poles Trip Frame Amps kAIC 21 1 20 BAB 100 10 6 2 20 BAB 100 10 4 2 PROVBAB2 1 1 PROV Main Devices Qty Poles Trip Frame Amps kAIC 1 3 100 BAB-H 100 10 Device Modifications: Ref #Description Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.30 0 A Eaton OXOBOXO LOFTS HPH1 PRL1a Customer Approval 1 of 1 Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com V2-T3-7 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Pow-R-Line C Panelboards Product Description Lighting and Distribution Panelboards Eaton’s assembled panelboards are designed for sequence phase connection of branch circuit devices. This allows complete flexibility of circuit arrangement (single-, two- or three-pole) to allow balance of the electrical load on each phase. Sturdy, rigid chassis assembly ensures accurate alignment of interior with panel front; prevents flexing and minimizes possibility of loosening or damage to current carrying parts during and after installation. Four-point in-and-out adjustment of panel interior is provided to meet critical depth dimensions on flush installations. This compensates for possible misalignment of box at installation. Main lugs are mechanical solderless type and approved for copper or aluminum conductors. Enclosures Boxes are code-gauge galvanized steel, which include a painted box finished in ANSI-61 light gray to match the trim. Standard panelboard cabinets are designed for indoor use. Alternate types are available for indoor and special purpose applications. All enclosures are furnished in accordance with Underwriters Laboratories standards and include wiring gutters with proper wire bending space. Special cabinets can be provided at an additional charge. The box dimensions shown are inside dimensions. For outside dimensions, add 1/4-inch (6.4 mm). Standard panelboard boxes are supplied without knockouts (blank endwalls). Fronts Fronts (trims) for all panelboards are made of code-gauge steel and have a high durability ANSI-61 light gray finish applied by a baked- on polyester powder coating paint system. The fronts for lighting and appliance branch circuit panelboards and small power distribution panelboards include a door with rounded corners and concealed hinges. A flush-type latch and lock assembly is included. All locks are keyed alike. These trims are available in both surface- and flush- mounted designs. EZ Trim Features Standard Door-in-Door with No Exposed Hardware or Sharp Edges (no Tools are Required for Installation) The Three-Piece Trim for Larger Power Distribution Panelboards Provides for Easy Handling and Installation Fronts for power distribution panelboards utilize a unique breaker front cover design in which each device has a dedicated bolt-on steel cover. The individual covers form a single deadfront for the panelboard that is used in conjunction with two wiring gutter covers to complete the trim. A door is not finished as part of the standard offering on these panelboards but can be provided, for an additional charge, using a deeper than standard box. V2-T3-8 Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Application Description Panelboard Selection Factors In selecting a panelboard, the following factors must be considered: ●Service (voltage and frequency) ●Interrupting capacity (fully or series rated) ●Ampere rating of main ●Ampere ratings of branches ●Environment Panelboard Short-Circuit Rating The short-circuit rating of Eaton’s assembled panelboards are test verified by, and listed with, Underwriters Laboratories (UL). Generally, these ratings are that of the lowest interrupting rated device in the panel. Certain exceptions to this rule exist where branch devices have been UL tested in combination with specific main devices having a higher interrupting rating. Where these defined main devices and branch breaker combinations are utilized, the series short-circuit rating of the assembled panelboard will be the same as the tested rating of the approved rated main device in series with the branches. Available main and branch breaker combinations are tabulated starting on Page V2-T3-16. All combinations shown are UL tested and listed. These series ratings apply to panels having main devices, or main lug only panelboards fed remotely by the device listed in the series ratings chart as the main, for which UL listed tests were conducted. Service Entrance Equipment The National Electrical Code (NEC) requires that: ●A panel used as service entrance equipment must be located near the point where the supply conductors enter the building ●A panelboard having main lugs only shall have a maximum of six service disconnects to de-energize the entire panelboard from the supply conductors. Where more than six disconnects are required, a main service disconnect must be provided ●A disconnectable electrical bond must be provided between the neutral and ground ●A service entrance type UL label must be factory installed ●Ground fault protection of equipment shall be provided for each service disconnect rated 1000A or more if the electrical service is a solidly grounded wye system of more than 150V to ground, but not exceeding 600V phase-to-phase Note: Service entrance panels must be identified as such on the order. Panelboard Standards In 2008, both the National Electrical Code (Article 408) and UL 67 were updated to remove the mandated 42-circuit limitation. Eaton offers panelboards with more than 42 circuits for those jurisdictions that have adopted the 2008 NEC or later. For jurisdictions that have| not adopted the 2008 or later version of the National Electrical Code, the 42-circuit limitation for Lighting and Appliance Branch Panelboards remains in place. Check with your local code officials to determine specific jurisdiction status. Panelboard Installation NEC requires that the operating handle of the topmost mounted device be no more than 6 feet 7 inches (2006.6 mm) above the finished floor and should be installed per NEC and manufacturer’s instructions. Additional boxes and fronts are required when the components required for one panelboard exceed the standard box dimensions. Multi-Section Panelboards When two or more separate enclosures are required, separate fronts for each box are standard. A common front can be furnished at additional charge. Interconnecting Multi- Section Panelboards When a panelboard, for connection to one feeder, must be furnished in more than one section (Box), each section must be furnished with main bus and terminals of the same rating, unless a main overcurrent device is provided in each section. Sub-feed or through-feed provisions must also be included (and priced) to provide connection capability to the second section. Note: Sub-feed or through-feed lugs cannot be used on any panelboard that is not protected by a single main overcurrent device either in the panelboard or immediately upstream, i.e., service entrance panelboards with main lugs only using the six disconnect rule. Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com V2-T3-9 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Sub-Feed Lugs Sub-feed lugs (see figure below) are one means of interconnecting multi-section panels. The sub-feed (second set of) lugs are mounted directly beside the main lugs. These are required in each section except the last panel in the lineup. The feeder cables are brought into the wiring gutter of the first section and connected to the main lugs. Another set of the same size cables are connected to the sub-feed lugs (Section 1) and are carried over to the main lugs of the adjacent panel. Cross connection cables are not furnished by Eaton. Sub-feed lugs are only available on main lug only panels. Note: Sub-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Sub-Feed Lugs Through-Feed Lugs Through-feed lugs (see figure below) are another method to interconnect multi-section panelboards. The incoming feeder cables are connected to the main lugs or main breaker at the bottom of panel (Section 1). Another set of lugs (through-feed) are located at the opposite end of the main bus. The interconnecting cables are connected to the through- feed lugs in Section 1 and are carried over to the main lugs in Section 2. The connection arrangement could be reversed, i.e., main lugs at top; through-feed lugs at bottom end of panel. Cross cables are not furnished by Eaton. Note: Through-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Through-Feed Lugs Box Box Conduit Neutral Neutral PanelPanelSection 1 Section 2 Section 1 Section 2 Box Box Conduit Neutral PanelPanelNeutral MainLugs Thru-FeedLugs MainLugs Cross Cables Incoming Feeder Cables Multiple Section Panelboard—Flush Mounted Shown below is the standard method for flush mounting multiple section lighting and distribution panelboards using standard flush trims. Multiple Section Panelboard Flush Mounted— Dimensions in Inches (mm) Overcurrent Protection The following requirements will be found in the NEC: Each lighting and appliance branch circuit panelboard shall be individually protected on the supply side by not more than two main circuit breakers or two sets of fuses having a combined rating not greater than that on the panelboard. Contractor to Mount Boxes 1-1/2-inch (38.1 mm) Apart to Allow for 3/4-inch (19.1 mm) Extension on Both Flush Trims Two Section Panelboard (Flush Mounting) Flush Trim Extends 3/4-inch (19.1 mm) Beyond Outside of Box on All Four Sides Outside Edge of BoxTrim Wall WallTrim Trim Conduit Nipple for Cross Wiring by Contractor 3/4(19.1)3/4(19.1) 1 1/2 (38.1) Top Section View 3/4(19.1) 3/4(19.1) 3/4(19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) V2-T3-10 Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Branch Circuit Loading for Lighting Panels The size of mains and branches should be selected based on the following: ●Motor circuits: NEC Article 430 ●Diversity factor ●Provision for future loading Exception Number 1: Individual protection for a lighting panelboard is not required when the panelboard feeder has overcurrent protection not greater than that of the panelboard. Exception Number 2: For existing installations, individual protection for lighting panelboards is not required where such panelboards are used as service equipment in supplying an individual residential occupancy and where any bus supplying 15 or 20A circuits is protected on the supply side by an overcurrent device. Ambient Temperatures The primary function of an overcurrent device is to protect the conductor and its insulation against overheating. In selecting the size of the devices and conductors, consideration should be given to the ambient temperature surrounding the conductors within and external to the panelboard. Cumulative heating within the panelboard may cause premature operation of the overcurrent protective devices. Underwriters Laboratories test procedures are based, in part, on 80% loading of panelboard branch circuit devices. The NEC limits the loading of overcurrent devices in panelboards to 80% of rating where in normal operation the load will continue for three hours or more. Further derating may be required, depending on such factors as ambient temperature, duty cycle, frequency or altitude. Exception: There is one exception to this rule in both UL and NEC. It applies to assemblies and overcurrent devices that have been listed for continuous duty at 100% of its rating. Special Conditions Standard panelboards, assembled with standard components, are adequate for most applications. However, special consideration should be given to those required for application under special conditions such as: ●Excessive vibration or shock ●Frequencies above 60 cycles ●Altitudes above 6600 feet (2011.7m) ●Damp environment (possible fungus growth) ●Compliance with federal, state and municipal electrical codes and standards Seismic Considerations The Uniform Building Code® and the International Building Code, as well as local and state building codes, place an emphasis on seismic building design requirements. Electrical distribution systems are treated as attachments to the building and therefore, fall into this category. All Eaton panelboards are seismic qualified at the highest possible level, and have been tested in accordance with ANSI C37.81. This standard quantifies actual earthquake conditions, as well as equipment seismic capability. Harmonic Currents Standard panelboard neutrals are rated for 100% of the panelboard current. However, since harmonic currents can cause overheated neutrals, an option is provided for neutrals to be rated at 200% (1200A maximum neutral for 600A main bus) of the panelboard phase current. Panelboards with the 200% rated neutral are UL listed as suitable for use with non- linear loads. Prior to specifying the 200% rated neutral, Eaton recommends a harmonic survey be conducted of the distribution system, be it new or existing. Surge Protective Devices The quality of power feeding sensitive electronic loads is critical to the reliable operation of any facility. In modern offices, hospitals, and manufacturing facilities, the most frequent causes of microprocessor-based equipment downtime and damage are voltage transients and electrical noise. Electrical loads and microprocessor-based equipment are highly susceptible to both high and low energy transients. High energy transients include lightning induced surges and power company switching. These high energy transients can destroy components instantly. More frequently the electrical system experiences low energy transients and high frequency noise. The effects of continual low energy transients and high frequency noise can cause erratic equipment performance or sudden failure of electronic circuit board components. Eaton can provide protective and diagnostic systems integral to panelboards. The surge protective device (SPD) is integrated into the panelboards using a “zero lead length” direct bus bar connection. Pow-R-Line 4 The SPD protects sensitive electronic equipment from the damaging effects of high and low energy transients, as well as high frequency noise. Standards and Certifications Eaton’s panelboards are designed to meet the following applicable industry standards, except where noted: ●Underwriters Laboratories: ●Panelboards: UL 67 ●Cabinets and Boxes: UL 50 Note: Only panelboards containing UL listed devices can be UL labeled. ●National Electrical Code ●NEMA Standards: PB 1 ●Federal Specification W-P-115c: ●Circuit Breakers— Type I Class I ●Fusible Switch— Type II Class I Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com V2-T3-11 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Technical Data and Specifications Panelboard Selection Guide Note 1 Fixed mounted only. Maximum Voltage Rating Maximum Main Rating (Amperes) AC Interrupting Capacity rms Symmetrical Amperes (kA) Panelboard Type Device Type AC DC MLO Main Device Branch Circuits Ampere Range Sub-Feed Breaker Maximum Amperes Fully Rated Series Rated PRL1a Breaker 240 — 600 600 15–100 600 10–22 22–100 PRL1R Breaker 240 — 225 225 15–100 — 10–22 22–100 PRL1aF Fusible 240 — 400 400 15–30 400 200 — PRL1a-LX Breaker 240 — 225 225 15–100 — 10–22 22–100 PRL2a Breaker 240 250 600 600 15–100 600 65 65–200 Breaker 480Y/277 250 600 600 15–100 600 14 22–150 PRL2R Breaker 240 — 225 225 15–100 — 10–22 22–200 Breaker 480Y/277 — 225 225 15–100 — 14 22–100 PRL2aF Fusible 480Y/277 — 400 400 15–30 400 200 — PRL2a-LX Breaker 240 250 225 225 15–100 — 65 65–200 Breaker 480Y/277 250 225 225 15–100 — 14 22–150 PRL3a Breaker 240 250 800 600 15–225 600 10–200 22–200 Breaker 480 250 800 600 15–225 600 14–100 22–150 Breaker 600 250 800 600 15–225 600 14–35 — PRL3E Breaker 240 250 600 600 15–125 400 25–100 100–200 Breaker 480Y/277 250 600 600 15–125 400 18–65 65–100 Breaker 480 250 600 600 15–125 400 18–65 65–100 PRL4B Breaker 240 600 1200 1200 15–1200 — 10–200 22–200 Breaker 480 600 1200 1200 15–1200 — 14–200 22–150 Breaker 600 600 1200 1200 15–1200 — 14–200 — PRL4D Breaker 240 — 1200 1200 1 600 — 65–200 — Breaker 480 — 1200 1200 1 600 — 35–100 — Breaker 600 — 1200 1200 1 600 — 18–50 — PRL4F Fusible 240 250 1200 1200 30–1200 — 100–200 — Fusible 600 250 1200 1200 30–1200 — 100–200 — PRL5P Breaker 240 250 1200 1200 15–1200 — 10–200 22–200 Breaker 480 250 1200 1200 15–1200 — 14–200 22–150 Breaker 600 250 1200 1200 15–1200 — 14–200 — Pow-R-Command™ Breaker 240 — 400 400 15–225 — 10–65 22–100 Breaker 480Y/277 — 400 400 15–225 — 14 65–100 Elevator Control Fusible 240 — 800 800 15–200 — 200 — Fusible 480Y/277 — 800 800 15–200 — 200 — Fusible 480 — 800 800 15–200 — 200 — V2-T3-12 Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Terminal Wire Ranges, Pressure-Type Al/Cu Terminals Except as Noted Note: All terminal sizes are based on wire ampacities corresponding to those shown in NEC Table 310.16 under the 75°C insulation columns (75°C wire). The use of smaller size, (in circular mills), regardless of insulation temperature rating, is not permitted. Where copper-aluminum terminals are supplied on designated panelboard types, best results are obtained if a suitable joint compound is applied when aluminum conductors are used. Check Eaton’s standard terminal sizes versus customer requirements. In particular, 400 and 800A breakers often require nonstandard lugs. Optional 750 kcmil mechanical screw-type terminals are available upon request. Panelboard dimensions may be affected, refer to Eaton. Standard Main Lug Terminals Wire Size Ranges for Ampere Capacity Panel Type 100 A 225 A 250 A 400 A 600 A 800 A 1200 A PRL1a #12–1/0 #6–300 kcmil — (2) #4–500 kcmil (2) 4/0–500 kcmil — — PRL2a #12–1/0 #6–300 kcmil — (2) #4–500 kcmil (2) 4/0–500 kcmil — — PRL1R #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRL2R #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRL1aF #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRL2aF #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRL3a #12–1/0 — #6–350 kcmil (2) #4–500 kcmil (2) #4–500 kcmil (3) #4–500 kcmil — PRL3E #12–1/0 — #6–350 kcmil (2) #4–500 kcmil (2) #4–500 kcmil — — PRL4 — — #4–500 kcmil (2) #4–500 kcmil (2) #4–500 kcmil (3) #4–500 kcmil (4) #4–500 kcmil PRL1a-LX#12–1/0#6–300 kcmil————— PRL2a-LX#12–1/0#6–300 kcmil————— PRCE #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRC100 #12–1/0 — #6–350 kcmil (2) #4–500 kcmil — — — PRC25 #12–1/0 #6–300 kcmil — (2) #4–500 kcmil — — — PRL5P———(1) #1/0–500 kcmil or (2) #1/0–250 kcmil (2) #4–500 kcmil (2) #2–500 kcmil or (3) #2–400 kcmil (4) #4–750 kcmil Elevator Control — — #4–500 kcmil (2) #4/0–500 kcmil (2) #4/0–500 kcmil (3) #4/0–500 kcmil — Volume 2—Commercial Distribution CA08100003E—April 2019 www.eaton.com V2-T3-13 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Standard Circuit Breaker Terminals FDPW Switch Terminals Elevator Control Panel Feeder Terminals Notes 1 LHH is 400A maximum. 2 Suitable for DC applications only. Breaker Type Ampere Rating Wire Range BAB, QBHW, BABRSP, HQP, QPHW 15–70 #14–#4 90–100 #8–1/0 EDB, EDS, ED, EDH, EDC 100–225 #4–4/0 or #6–300 kcmil EGB, EGE, EGS, EGH 15–50 #14–3/0 AL/CU 60–125 #6–3/0 AL/CU EHD, FDB, FD, HFD, FDC, HFDDC 2 15–100 #14–1/0 125–225 #4–4/0 FCL 15–100 #14–1/0 GHB, HGHB, GHQ, GHQRSP 15–30 #14–#10 25–100 #10–1/0 EGB, EGS, EGH 15–50 #14–1/0 60–125 #6–2/0 JD, HJD, JDC, HJDDC 2 70–250 #4–350 kcmil DK 250–350 250–500 kcmil 400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil KD, HKD, KDC, HKDDC, 2 CKD, CHKD 225 (1) #3–350 kcmil 350 (2) 3/0–250 kcmil or 400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil LHH 150–400 #2–500 kcmil 150–400 (2) #2–500 kcmil 150–400 (1) 500–750 kcmil LGE, LGH, LGC, LGU, LHH 1 250–400 (1) #2–500 kcmil 500–600 (2) #2–500 kcmil LD, HLD, LDC, HLDDC 2 CLD, CHLD 300–500 (2) 250–350 kcmil 600 (2) 400–500 kcmil MDL, HMDL, HMDLDC 2 CMDL, CHMDL 400–600 (2) #1–500 kcmil 700–800 (3) 3/0–400 kcmil ND, HND, CND, CHND, NDC, CNDC 800–1000 (3) 3/0–400 kcmil 1200 (4) 4/0–500 kcmil LCL 125–225 (1) #6–350 kcmil 250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil FB-P 15–100 #14–1/0 LA-P 70–225 #6–350 kcmil 250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil NB-P, NBDC 2 300–700 (2) #1–500 kcmil 800 (3) 3/0–400 kcmil NGS, NGH, NGC NGS-C, NGH-C, NGC-C 400–1200 (4) 4/0–500 kcmil (Cu/Al) Ampere Rating Wire Range 30 #14–1/0 60 #14–1/0 100 #14–1/0 200 #4–300 kcmil 400 250–750 kcmil or (2) 3/0–250 kcmil 600 (2) #4–600 kcmil or (4) 3/0–250 kcmil 800 (3) 250–750 kcmil or (6) 3/0–250 kcmil 1200 (4) 250–750 kcmil or (8) 3/0–250 kcmil Ampere Rating Wire Range 30 #14–1/0 60 #14–1/0 100 #14–1/0 200 #4–300 kcmil Detail Bill of Material Page 1 of 1 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Item No. Qty Product Description 1 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures: Catalog No 3MCB1000R Designation BLDGS G-L Qty List of Materials 1 [3MCB1000R] Gen Panels & Transfer Switches 1 [37MM140R1240] Gen Panels & Transfer Switches 10 [37MMBK] Barrier for Commercial Meter Stacks 9 [35MM420R12] Gen Panels & Transfer Switches 35 [CV2100XMM] 100A, 65k, 2-Pole, Bolt-on Type Main Tenant Circuit Breaker for Commercial Stack 1 [37MMCKA] Blank Meter Cover Kit for Commercial Meter Stacks Item No. Qty Product Description 1 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures: Catalog No 3MCB1200RA Designation BLDGS A-F Qty List of Materials 1 [3MCB1200RA] Gen Panels & Transfer Switches 1 [37MM140R1240] Gen Panels & Transfer Switches 11 [37MMBK] Barrier for Commercial Meter Stacks 9 [35MM420R12] Gen Panels & Transfer Switches 38 [CV2100XMM] 100A, 65k, 2-Pole, Bolt-on Type Main Tenant Circuit Breaker for Commercial Stack 1 [35MM220R12] Gen Panels & Transfer Switches Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction thereof for the time the shipment is delayed. Group Metering General Information Specifications Utility Approval NON-EUSERC Bus Type Aluminum Breaker Information 35 CV2100XMM 100A, 65k, 2-Pole, Bolt-on Type Main Tenant Circuit Breaker for Commercial Stack Miscellaneous Specifications Approval Drawings:No Autocad Drawings:No Standard Instructions Books:No Certified Test Report (Std):No Enclosure Properties Struct #Width Depth Description/Modifications Catalog Number 1 20.2 13.8 Structure, 3MCB1000R 2 18.3 9 Structure, 37MM140R1240 3 19.3 9.56 Structure, 35MM420R12 4 19.3 9.56 Structure, 35MM420R12 5 19.3 9.56 Structure, 35MM420R12 6 19.3 9.56 Structure, 35MM420R12 7 19.3 9.56 Structure, 35MM420R12 8 19.3 9.56 Structure, 35MM420R12 9 19.3 9.56 Structure, 35MM420R12 10 19.3 9.56 Structure, 35MM420R12 11 19.3 9.56 Structure, 35MM420R12 Total of 11 Structures, Total Width of 212.2 Inches Note: 400A KD-type breakers are factory installed in the 400A Commercial Stacks NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 8.0.2.0 0 A Eaton OXOBOXO LOFTS BLDGS G-L Group Metering Customer Appr. 1 of 2 1Main2131234412345123461234712348123491234101234111234Structure1234567891011Wdth-InchesWdth-MM20.218.319.319.319.319.319.319.319.319.319.3513464490490490490490490490490490Depth-InchesDepth-MM13.899.569.569.569.569.569.569.569.569.56350228242242242242242242242242242Height-InchesHeight-MM47.652.6266.6266.6266.6266.6266.6266.6266.6266.6266.6212091336169216921692169216921692169216921692Tab Size-InchesTab Size-MM50NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 8.0.2.0 0 A Eaton OXOBOXO LOFTS BLDGS G-L Group Metering Customer Appr. 2 of 2 7865432178654321DCBADCBATITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFDC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.Powering Business WorldwideMETERING DIMENSION DWG FOR METER CTR BREAKER MAIN 800-1200AM.B.2019/08/1996-263107INCHESN/A111989Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1000R BLDGS G-L 7865432178654321DCBADCBADSD_DFM_ACAD_WEB.DWGTITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFDC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.MULTIPLE METERING DIMENSIONSM. CASTRO2013/12/1996-4754002INCHESN/A112000Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1000R BLDGS G-L 1234DCBADCBA2341DSD_CFM_ACAD_WEB.DWGTITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFCC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.',0(16,216)25‘0(7(5&(17(5M. CASTRO2013/12/1796-1988002INCHESN/A111983Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1000R BLDGS G-L Group Metering General Information Specifications Utility Approval NON-EUSERC Bus Type Aluminum Breaker Information 38 CV2100XMM 100A, 65k, 2-Pole, Bolt-on Type Main Tenant Circuit Breaker for Commercial Stack Miscellaneous Specifications Approval Drawings:No Autocad Drawings:No Standard Instructions Books:No Certified Test Report (Std):No Enclosure Properties Struct #Width Depth Description/Modifications Catalog Number 1 20.2 13.8 Structure, 3MCB1200RA 2 18.3 9 Structure, 37MM140R1240 3 19.3 9.56 Structure, 35MM420R12 4 19.3 9.56 Structure, 35MM420R12 5 19.3 9.56 Structure, 35MM420R12 6 19.3 9.56 Structure, 35MM420R12 7 19.3 9.56 Structure, 35MM420R12 8 19.3 9.56 Structure, 35MM420R12 9 19.3 9.56 Structure, 35MM420R12 10 19.3 9.56 Structure, 35MM420R12 11 19.3 9.56 Structure, 35MM420R12 12 18.3 9.56 Structure, 35MM220R12 Total of 12 Structures, Total Width of 230.5 Inches Note: 400A KD-type breakers are factory installed in the 400A Commercial Stacks NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 8.0.2.0 0 A Eaton OXOBOXO LOFTS BLDGS A-F Group Metering Customer Appr. 1 of 2 1Main21312344123451234612347123481234912341012341112341212Structure123456789101112Wdth-InchesWdth-MM20.218.319.319.319.319.319.319.319.319.319.318.3513464490490490490490490490490490464Depth-InchesDepth-MM13.899.569.569.569.569.569.569.569.569.569.56350228242242242242242242242242242242Height-InchesHeight-MM47.652.6266.6266.6266.6266.6266.6266.6266.6266.6266.6252.62120913361692169216921692169216921692169216921336Tab Size-InchesTab Size-MM50NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 8.0.2.0 0 A Eaton OXOBOXO LOFTS BLDGS A-F Group Metering Customer Appr. 2 of 2 7865432178654321DCBADCBATITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFDC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.Powering Business WorldwideMETERING DIMENSION DWG FOR METER CTR BREAKER MAIN 800-1200AM.B.2019/08/1996-263107INCHESN/A111989Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1200RA BLDGS A-F 7865432178654321DCBADCBADSD_DFM_ACAD_WEB.DWGTITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFDC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.MULTIPLE METERING DIMENSIONSM. CASTRO2013/12/1996-4754002INCHESN/A112000Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1200RA BLDGS A-F 1234DCBADCBA2341DSD_CFM_ACAD_WEB.DWGTITLE / DESCRIPTIONSHEETDRAFTER/DESIGNERDATE (YYYY/MM/DD)DRAWINGNUMBERREVISIONSIZEUNLESS OTHERWISE SPECIFIEDDIMENSIONS INSCALEOFCC Eaton Corporation, All Rights ReservedTHE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOTTO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSEWHICH FURNISHED.',0(16,216)25‘0(7(5&(17(5M. CASTRO2013/12/1796-1988002INCHESN/A111983Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS 3MCB1200RA BLDGS A-F Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-101 4 4.10Metering Products Group Metering Main Service Modules Product Description ●Main terminal box ●Main circuit breaker ●Main bolted pressure switch ●Main fusible switch ●Main fusible switch with pull box ●Underground pull box Application Description Main Circuit Breakers with Busway Connections The Service Entrance Product Team announces the availability of both main fusible switch and main circuit breaker group metering mains with busway connections. This offering provides us with the ability to offer multiple tenant metering in high rise apartment buildings where riser busway is used. Features, Benefits and Functions Eaton’s Main Service Module ●Offering: main terminal/lug compartment, main circuit breaker, main fusible switch, main bolted pressure switch, main fusible switch with pull box (meets EUSERC electrical requirements), underground pull box termination compartment without cross bus (meets EUSERC electrical requirements) ●Mechanically and electrically built for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS modular metering stacks ●For integrated system short-circuit ratings with main devices, see series ratings on Page V1-T4-144 ●All main service modules include both left and right horizontal bus closure plates ●Two-pole devices are applied to single-phase, three-wire, 120/240 V or 208Y/120 V systems, three-pole devices to 208Y/ 240 V or 120/240 V delta systems ●Single-phase mains couple to any modular metering stack (1MM, 3MM, 35MM, 37MM, 35SS and 37SS) ●Three-phase mains require three-phase bussed stacks. These modular metering stacks are 3MM, 35MM, 37MM, 35SS and 37SS ●If the ampere rating of the main service module is greater than the horizontal bus rating of the meter stack (residential or commercial), the main service module must be center fed. Examples: 1200 A Main Circuit Breaker (1MCB1200R) with an 800 A residential stack (1MM512R). 1600 A Main Terminal Box (3MTB1600R) with a 1200 A residential stack (3MM212R12) ●Most main service modules are available with aluminum or copper bus Main Circuit Breakers with Busway Connections ●Three-phase, 400–200 A main circuit breakers ●Three-phase, 400–800 A main fusible switches ●Simple bridge joint connection ●Variety of options: ●Right or left mounting ●Internal ground or housing ground ●The MFS/MCB and busway connector are supplied completely assembled V1-T4-102 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Catalog Number Selection When Ordering: 1. Determine catalog number of Main Service Module. 2. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T4-127 or V1-T4-137). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T4-138 and V1-T4-139. Phase 1 = Single-phase 3 = Three-phase Ampere Rating 400 A 600 A 800 A 1000 A 1200 A 1400 A 1600 A 2000 A Bus Material C = Copper bus Blank= Aluminum bus Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box MTBE =Main terminal box with utility pull box MCBE =Main circuit breaker with utility pull box Accessories and Additional Options BLK= Box lug kit (accessory) CLK= Compression lug (accessory) B = Bottom feed T = Top feed UG= Pull box Blank= No options Enclosure R = NEMA 3R 3 MTB 400 R C Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-103 4 4.10Metering Products Group Metering Product Selection Main Terminal Box ●Phase and neutral lugs are included ●Top or bottom feed: ●For top feed, use Myer type hub ●Indoor or outdoor ●Terminal box UL listed short-circuit rating is the least AIC rating of any installed main tenant breaker—to a maximum of 100,000 rms symmetrical amperes Main Terminal Box Main Terminal Box Riser Panel Eaton’s Main Terminal Box Riser Panel is a main terminal box with offset lugs on each phase to allow riser cables to pass through the main service module. These panels are used in the construction of assisted living homes, dormitories, public housing complexes and apartments. Main Terminal Box Riser Panel Notes 1 1200 A main devices must be center fed when installing 800 A residential meter stacks. 1600 A main devices must be center fed when installing 800–1200 A residential and commercial meter stacks. 2 For 400 A units, to obtain (4) 750 kcmil cables per phase—order quantity 4 1MPLK2. Kit contains one lug. 3 For compression lug landing kits for 600 A units, order 3MTB600CLK. Kit includes lug landings for three phases and neutral. 4 For 800 A units, to obtain (4) 1/0–300 kcmil or (2) 1/0–750 kcmil cables per phase—order catalog number 3MTB800BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 5 For 800 A and 1200 A units, for compression lug landing kits, order 3MTB1200CLK. Kit includes lug landings for three-phase and neutral. 6 For 1200 A units, to obtain (6) 1/0–300 kcmil or (3) 750 kcmil cables per phase—order catalog number 3MTB1200BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 7 Meets EUSERC electrical requirements and eliminates the need to add additional pull box section. Reference drawing EUSERC DWG-343. 8 For 1600 A units, to obtain (4) 750 kcmil cables per phase—order catalog number 3MTB1600BLK, one lug kit per main terminal box ordered. For a 1600 A compression lug landing kit, order catalog number 3MTB1600CLK. 9 Quantity (10) lugs per phase—quantity (5) lugs incoming and quantity (5) lugs outgoing per phase. Ampere Rating Line Side Lug and Wire Sizes—Included System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 400 (1) #6–600 or (2) 1/0–250 kcmil 2 Use three-phase 3MTB400R 600 (2) 250–500 kcmil 3 Use three-phase 3MTB600R 800 (4) 250–500 kcmil 45 1MTB800R 3MTB800R 1200 1 (4) 250–500 kcmil 56 1MTB1200R 3MTB1200R Aluminum Bus (EUSERC) 400 Crimp lug landing pads (no lugs included)1MTBE400R 7 3MTBE400R 7 800 Crimp lug landing pads (no lugs included)1MTBE800R 7 3MTBE800R 7 Copper Bus (Premium Offering) 400 (1) #6–600 or (2) 1/0–250 kcmil 2 Use three-phase 3MTB400RC 600 (2) 250–500 kcmil 3 Use three-phase 3MTB600RC 800 (4) 250–500 kcmil 45 1MTB800RC 3MTB800RC 1200 1 (4) 250–500 kcmil 56 1MTB1200RC 3MTB1200RC 1600 1 (6) 500 kcmil 8 1MTB1600RC 3MTB1600RC Main Terminal Box System Voltage Ampere Rating Line and Load Side Lug and Wire Sizes Included 120/240 Vac Single-Phase, Three-Wire Catalog Number 120/208 Vac Three-Phase, Four-Wire Catalog Number Copper Bus (Standard Offering) 1200 #2 AWG–750 kcmil 19 Use three-phase 3MTB1200RCRIS 1600 #2 AWG–750 kcmil 19 Use three-phase 3MTB1600RCRIS V1-T4-104 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Main Circuit Breaker ●Phase and neutral lugs included. If additional neutral lugs are needed, order 1MCB1200NLK for (3) 1/0–750 or (6) 1/0–300 kcmil ●For shunt trip mains, order the field-installable shunt trip kit in this volume, Tab 1, section 1.1 ●For overhead feed, use Myer type hub. Verify local utility approval ●For compression lugs on 400, 600, 800, 1000 and 1200 A units, add CL to the end of the part number (includes copper lug pads for lines and neutral) ●1200 A or greater main devices must be center fed when installing 800 A residential meter stacks ●1400, 1600 and 2000 A main devices must be center fed when installing 800 and 1200 A residential and commercial meter stacks Main Circuit Breaker Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Reference drawing EUSERC DWG-315. 3 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 4 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 5 Main devices with a rating greater than 800 A can be used with 800 A residential modular stacks, but only as a center fed main. Main Ampere Rating Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 2 250 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB250R 3MCB250R 250 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB250R 3MHCB250R 300 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB300R 3MCB300R 300 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB300R 3MHCB300R 350 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB350R 3MCB350R 350 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB350R 3MHCB350R 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB400R 3 3MCB400R 3 400 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB400R 3 3MHCB400R 3 500 LD Bottom/top 65 (2) 400–500 kcmil 1MCB500R 3MCB500R 500 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB500R 3MHCB500R 600 LD Bottom/top 65 (2) 400–500 kcmil 1MCB600R 3 3MCB600R 3 600 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB600R 3 3MHCB600R 3 700 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB700R 3MHCB700R 700 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB700R 3MCB700R 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800R 3 3MCB800R 3 800 MDL Bottom/top 65 (2) 500–750 kcmil 1MCB800R750 3MCB800R750 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800R 3 3MHCB800R 3 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB900R 5 3MCB900R 5 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB900R 5 3MHCB900R 5 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB1000R 35 3MCB1000R 35 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750 3MCB1000R750 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB1000R 35 3MHCB1000R 35 1200 NGS Bottom 65 (4) 4/0–500 kcmil 4 1MCB1200R 35 3MCB1200R 35 1200 NGH Bottom 100 (4) 4/0–500 kcmil 4 1MHCB1200R 35 3MHCB1200R 35 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750 Main Circuit Breaker Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-105 4 4.10Metering Products Group Metering Main Circuit Breaker Main Circuit Breaker, continued Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Reference drawing EUSERC DWG-315. 3 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 4 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 5 Main devices with a rating greater than 800 A can be used with 800 A residential modular stacks but only as a center fed main. 6 If (6) #2–600 kcmil lugs are needed, order TA2000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA2000N. 7 Copper bus. 8 Main devices with a rating greater than 1200 A can be used with residential and commercial modular metering stacks but only as a center fed main. 9 Only to be used in center feed applications with 1200 A meter stacks. Not to be used with 800 A stacks. Main Ampere Rating Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (EUSERC) 2 300 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE300R 3MCBE300R 350 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE350R 3MCBE350R 400 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE400R 3MCBE400R 400 HKD Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE400R 3MHCBE400R 500 LD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE500R 3MCBE500R 600 LD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE600R 3MCBE600R 600 HLD Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE600R 3MHCBE600R 800 MDL Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE800R 3MCBE800R 800 HMDL Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE800R 3MHCBE800R 1000 NGS Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE1000R 3MCBE1000R 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included)1MCBE1200R 3MCBE1200R 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MHCBE1200R 3MHCBE1200R Copper Bus (Premium Offering) 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0-500 kcmil 1MCB400RC 3 3MCB400RC 3 400 HKD Bottom/top 100 2/0–500 kcmil 1MHCB400RC 3 3MHCB400RC 3 600 LD Bottom/top 65 (2) 300–500 kcmil 1MCB600RC 3 3MCB600RC 3 600 HLD Bottom/top 100 (2) 300–500 kcmil 1MHCB600RC 3 3MHCB600RC 3 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800RC 3 3MCB800RC 3 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800RC 3 3MHCB800RC 3 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB900RC 5 3MCB900RC 5 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB900RC 5 3MHCB900RC 5 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750C 3MCB1000R750C 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB1000RC 35 3MCB1000RC 35 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB1000RC 35 3MHCB1000RC 35 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750C 1200 NGS Bottom 65 (4) 4/0–500 kcmil 4 1MCB1200RC 35 3MCB1200RC 35 1200 NGH Bottom 100 (4) 4/0–500 kcmil 4 1MHCB1200RC 35 3MHCB1200RC 35 1400 RGH Bottom 100 (4) 500–1000 kcmil 6 1MCB1400RBC 57 3MCB1400RBC 57 1400 RGH Top 100 (4) 500–1000 kcmil 6 1MCB1400RT 8 3MCB1400RT 8 1600 RGH Bottom 100 (4) 500–1000 kcmil 6 1MCB1600RBC 78 3MCB1600RBC 78 1600 RGH Top 100 (4) 500–1000 kcmil 6 1MCB1600RT 8 3MCB1600RT 8 2000 RGH Bottom 100 (6) #2–600 kcmil 1MCB2000RBC 79 3MCB2000RBC 79 2000 RGH Top 100 (6) #2–600 kcmil 1MCB2000RT 9 3MCB2000RT 9 Copper Bus (EUSERC) 2 1000 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MCBE1000RC 3MCBE1000RC 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included)1MCBE1200RC 3MCBE1200RC 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MHCBE1200RC 3MHCBE1200RC Main Circuit Breaker V1-T4-106 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Main Fusible Switches ●Fuses not included ●Main lugs and neutral included with device ●100 kAIC rating on switches with Class T fuses installed. If converting to Class H, the kAIC rating is 10 and if converted to Class R, the kAIC rating is 200 Note: This is the fuse rating, switch still rated at 100 kAIC. ●800 A top and bottom fed units are supplied with Class T fuse clips as standard. The Class T fuse clips are field convertible to Class L by repositioning. No kit is needed ●Barrier kits available for 400–800 A fusible switches: Bottom feed—3MFSBBK, Top feed—3MFSTBK Main Fusible Switches Notes 1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS56FK kit will convert three poles. 2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS66FK kit will convert three poles. 3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. 4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral). 5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral). 6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral). 7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral). Ampere Rating Feed Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 400 Bottom T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RB 3MFS400RB 400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RT 3MFS400RT 600 Bottom T 2 (2) #2–600 kcmil 45 1MFS600RB 3MFS600RB 600 Top T 2 (2) #2–600 kcmil 56 1MFS600RT 3MFS600RT 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RB 3MFS800RB 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RT 3MFS800RT 1200 Bottom T, L 3 (4) #2–600 kcmil 7 1MFS1200RB 3MFS1200RB Copper Bus (Premium Offering) 400 Bottom T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RBC 3MFS400RBC 400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RTC 3MFS400RTC 600 Bottom T 2 (2) #2–600 kcmil 45 1MFS600RBC 3MFS600RBC 600 Top T 2 (2) #2–600 kcmil 56 1MFS600RTC 3MFS600RTC 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RBC 3MFS800RBC 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RTC 3MFS800RTC 1200 Bottom T, L 3 (4) #2–600 kcmil 7 1MFS1200RBC 3MFS1200RBC Main Fusible Switches Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-107 4 4.10Metering Products Group Metering Main Fusible Switch with Utility Pull Box ●Fuses not included ●Includes lug landing pads on line side and neutral ●Spacer kit 3MMBSK required when stacks are mounted on right-hand side in EUSERC areas ●100 kAIC rating on switches with Class T fuse clips installed Main Fusible Switch with Utility Pull Box 1 Utility Pull Box ●Includes lug landing pads on line side and neutral ●Requires cable connection in field to main device; does not include horizontal cross bus Pull Box 3 Notes 1 Reference drawing EUSERC DWG-315. 2 Pull box section includes landing studs for line side compression lugs. Wire sizes refer to load side connection. 3 Reference drawing EUSERC DWG-343. Ampere Rating Feed Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 400 Bottom T 2 1MFS400RUG 3MFS400RUG 600 Bottom T 2 1MFS600RUG 3MFS600RUG 800 Bottom T, L 2 1MFS800RUG 3MFS800RUG 1200 Bottom T 2 1MFS1200RUG 3MFS1200RUG Copper Bus (Premium Offering) 400 Bottom T 2 1MFS400RUGC 3MFS400RUGC 600 Bottom T 2 1MFS600RUGC 3MFS600RUGC 800 Bottom T, L 2 1MFS800RUGC 3MFS800RUGC 1200 Bottom T 2 1MFS1200RUGC 3MFS1200RUGC Main Fusible Switch with Utility Pull Box Ampere Rating Feed Line Side Lug Information Load Side Lug Information for Cable Connection to Main Disconnect System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 400 Bottom 2 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400R 3UGPB400R 800 Bottom 2 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800R 3UGPB800R 1200 Bottom 2 (4) #2–600 kcmil 1UGPB1200R 3UGPB1200R Copper Bus (Premium Offering) 400 Bottom 2 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400RC 3UGPB400RC 800 Bottom 2 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800RC 3UGPB800RC 1200 Bottom 2 (4) #2–600 kcmil 1UGPB1200RC 3UGPB1200RC V1-T4-108 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Main Bolted Pressure Contact Switches ●Add suffix ST to catalog number for shunt trip ●Fuses not included ●100 kAIC rating on switches with Class L fuses installed Main Bolted Pressure Contact Switches Ampere Rating Feed Class Fuse Clips (Fuses Not Included) System Voltage Line Side Box Lugs and Wire Sizes (Included) 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Copper Bus 1200 Bottom L 1BPS1200RB 3BPS1200RB (4) #4–600 kcmil 1200 Top L 1BPS1200RT 3BPS1200RT (4) #4–600 kcmil 1600 Bottom L Use three-phase 3BPS1600RB (6) #4–600 kcmil 1600 Top L Use three-phase 3BPS1600RT (6) #4–600 kcmil 2000 Bottom L Use three-phase 3BPS2000RB (8) #4–600 kcmil 2000 Top L Use three-phase 3BPS2000RT (8) #4–600 kcmil Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-109 4 4.10Metering Products Group Metering Main Circuit Breaker with Busway Connection Verify proper left/right–bus/main phasing. Note: “Right” means that the bus duct is to the right of the main and “left” means that the bus duct is to the left of the main. (See Dimension/ Layout section for clarification.) Main Circuit Breaker with Busway Connection Ampere Rating Feed System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Opposite Phasing Right or Left Side 400 Bottom 3MFS400BCRGTO Internal TO Right 600 Bottom 3MFS600BCRGTO Internal TO Right 800 Bottom 3MFS800BCRGTO Internal TO Right 400 Bottom 3MFS400BCLGTO Internal TO Left 600 Bottom 3MFS600BCLGTO Internal TO Left 800 Bottom 3MFS800BCLGTO Internal TO Left 400 Bottom 3MFS400BCRGT Internal T Right 600 Bottom 3MFS600BCRGT Internal T Right 800 Bottom 3MFS800BCRGT Internal T Right 400 Bottom 3MFS400BCLGT Internal T Left 600 Bottom 3MFS600BCLGT Internal T Left 800 Bottom 3MFS800BCLGT Internal T Left 400 Bottom 3MFS400BCRNTO Housing TO Right 600 Bottom 3MFS600BCRNTO Housing TO Right 800 Bottom 3MFS800BCRNTO Housing TO Right 400 Bottom 3MFS400BCLNTO Housing TO Left 600 Bottom 3MFS600BCLNTO Housing TO Left 800 Bottom 3MFS800BCLNTO Housing TO Left 400 Bottom 3MFS400BCRNT Housing T Right 600 Bottom 3MFS600BCRNT Housing T Right 800 Bottom 3MFS800BCRNT Housing T Right 400 Bottom 3MFS400BCLNT Housing T Left 600 Bottom 3MFS600BCLNT Housing T Left 800 Bottom 3MFS800BCLNT Housing T Left 400 Bottom 3MCB400BCRGT Internal T Right 400 Bottom 3HMCB400BCRGT Internal T Right 600 Bottom 3MCB600BCRGT Internal T Right 600 Bottom 3HMCB600BCRGT Internal T Right 800 Bottom 3MCB800BCRGT Internal T Right 800 Bottom 3HMCB800BCRGT Internal T Right 1000 Bottom 3MCB1000BCRGT Internal T Right 1000 Bottom 3HMCB1000BCRGT Internal T Right 1200 Bottom 3MCB1200BCRGT Internal T Right 1200 Bottom 3HMCB1200BCRGT Internal T Right 400 Bottom 3MCB400BCLGT Internal T Left 400 Bottom 3HMCB400BCLGT Internal T Left 600 Bottom 3MCB600BCLGT Internal T Left 600 Bottom 3HMCB600BCLGT Internal T Left 800 Bottom 3MCB800BCLGT Internal T Left 800 Bottom 3HMCB800BCLGT Internal T Left 1000 Bottom 3MCB1000BCLGT Internal T Left 1000 Bottom 3HMCB1000BCLGT Internal T Left 1200 Bottom 3MCB1200BCLGT Internal T Left 1200 Bottom 3HMCB1200BCLGT Internal T Left 400 Bottom 3MCB400BCRNT Housing T Right 400 Bottom 3HMCB400BCRNT Housing T Right 600 Bottom 3MCB600BCRNT Housing T Right 600 Bottom 3HMCB600BCRNT Housing T Right 800 Bottom 3MCB800BCRNT Housing T Right 800 Bottom 3HMCB800BCRNT Housing T Right 1000 Bottom 3MBC1000BCRNT Housing T Right 1000 Bottom 3HMBC1000BCRNT Housing T Right Using this information, select the correct main device catalog number per the selection chart. Main Circuit Breaker with Busway Connection, continued Ampere Rating Feed System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Opposite Phasing Right or Left Side 1200 Bottom 3MCB1200BCRNT Housing T Right 1200 Bottom 3HMCB1200BCRNT Housing T Right 400 Bottom 3MCB400BCLNT Housing T Left 400 Bottom 3HMCB400BCLNT Housing T Left 600 Bottom 3MCB600BCLNT Housing T Left 600 Bottom 3HMCB600BCLNT Housing T Left 800 Bottom 3MCB800BCLNT Housing T Left 800 Bottom 3HMCB800BCLNT Housing T Left 1000 Bottom 3MCB1000BCLNT Housing T Left 1000 Bottom 3HMCB1000BCLNT Housing T Left 1200 Bottom 3MCB1200BCLNT Housing T Left 1200 Bottom 3HMCB1200BCLNT Housing T Left 400 Bottom 3MCB400BCRGTO Internal TO Right 400 Bottom 3HMCB400BCRGTO Internal TO Right 600 Bottom 3MCB600BCRGTO Internal TO Right 600 Bottom 3HMCB600BCRGTO Internal TO Right 800 Bottom 3MCB800BCRGTO Internal TO Right 800 Bottom 3HMCB800BCRGTO Internal TO Right 1000 Bottom 3MCB1000BCRGTO Internal TO Right 1000 Bottom 3HMCB1000BCRGTO Internal TO Right 1200 Bottom 3MCB1200BCRGTO Internal TO Right 1200 Bottom 3HMCB1200BCRGTO Internal TO Right 400 Bottom 3MCB400BCLGTO Internal TO Left 400 Bottom 3HMCB400BCLGTO Internal TO Left 600 Bottom 3MCB600BCLGTO Internal TO Left 600 Bottom 3HMCB600BCLGTO Internal TO Left 800 Bottom 3MCB800BCLGTO Internal TO Left 800 Bottom 3HMCB800BCLGTO Internal TO Left 1000 Bottom 3MCB1000BCLGTO Internal TO Left 1000 Bottom 3HMCB1000BCLGTO Internal TO Left 1200 Bottom 3MCB1200BCLGTO Internal TO Left 1200 Bottom 3HMCB1200BCLGTO Internal TO Left 400 Bottom 3MCB400BCRNTO Housing TO Right 400 Bottom 3HMCB400BCRNTO Housing TO Right 600 Bottom 3MCB600BCRNTO Housing TO Right 600 Bottom 3HMCB600BCRNTO Housing TO Right 800 Bottom 3MCB800BCRNTO Housing TO Right 800 Bottom 3HMCB800BCRNTO Housing TO Right 1000 Bottom 3MCB1000BCRNTO Housing TO Right 1000 Bottom 3HMCB1000BCRNTO Housing TO Right 1200 Bottom 3MCB1200BCRNTO Housing TO Right 1200 Bottom 3HMCB1200BCRNTO Housing TO Right 400 Bottom 3MCB400BCLNTO Housing TO Left 400 Bottom 3HMCB400BCLNTO Housing TO Left 600 Bottom 3MCB600BCLNTO Housing TO Left 600 Bottom 3HMCB600BCLNTO Housing TO Left 800 Bottom 3HMCB800BCLNTO Housing TO Left 800 Bottom 3HMCB800BCLNTO Housing TO Left 1000 Bottom 3MCB1000BCLNTO Housing TO Left 1000 Bottom 3HMCB1000BCLNTO Housing TO Left 1200 Bottom 3MCB1200BCLNTO Housing TO Left 1200 Bottom 3HMCB1200BCLNTO Housing TO Left V1-T4-110 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Dimensions Approximate Dimensions in Inches (mm) Dimensions (Not to be Used for Construction Purposes) Main Device Width Height Depth Mounting Center Line of Wall Mounting Bracket Knockouts in Bottom Endwalls Except No KOs for Top Feed Switch or Bolted Pressure Switch Conduit Diameter KO Dwg.ABCDEF Inches mm Terminal Box 400 and 600 A 13.50 (342.9) 48.75 (1238.3) 7.00 (177.8) —54.00 (1371.6) 30.63 (777.9)(1) 2.50, 3.00, 3.50, 4.00 (1) 0.50 (1) 63.5, 76.2, 88.9, 101.6 (1) 12.7 1 800 and 1200 A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.1, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1600 A 32.88 (835.2) 60.13 (1527.3) 11.44 (290.6) 16.00 (406.4) 64.13 (1628.9) 38.59 (980.2)(1) 0.75, 1.00, 1.25, 1.50 (5) 3.00, 3.50, 4.00, 5.00 (1) 19.1, 25.4, 31.8, 38.1 (5) 76.2, 88.9, 101.6, 127.0 3 Main Circuit Breaker with Box Lugs 400–1200 A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00,3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1400–2000 A 24.88 (632.0) 57.13 (1451.0) 14.88 (378.0) 16.00 (406.4) 57.13 (1451.0) 44.00 (1117.6)——— Main Circuit Breaker with Compression Lugs 400–1200 A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.60 2 Main Fusible Switch Bottom feed 400–800 A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Top feed 400–800 A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 18.13 (460.4)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1200 A 33.50 (850.9) 52.75 (1339.9) 11.88 (301.8) 16.00 (406.4) 56.25 (1428.8) 30.75 (781.1)(5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 Bolted Pressure Switch 36.50 (927.1) 66.50 (1689.1) 19.50 (495.3) 28.00 (711.2) 60.00 (1524.0) 30.63 (777.9)——— Main Fusible Switch with Pull Box 400 A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800 A (single-phase) 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800 A (three-phase) 25.06 (636.5) 61.00 (1549.4) 11.75 (298.5) 17.00 (431.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 4 1200 A 33.50 (850.9) 61.50 (1562.1) 11.88 (301.8) 16.00 (406.4) 65.25 (1657.4) 48.00 (1219.2)(5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 Main Circuit Breaker with Pull Box (EUSERC) 400 A 20.01 (508.2) 60.44 (1535.2) 11.14 (283.0) 12.00 (304.8) 65.11 (1653.8) 39.75 (1009.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 800 A 24.88 (632.0) 60.94 (1547.9) 11.14 (283.0) 17.00 (431.8) 64.88 (1648.0) 39.81 (1011.2)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 1200 A 33.00 (838.2) 61.14 (1553.0) 11.32 (287.5) 16.00 (406.4) 65.25 (1657.4) 43.56 (1106.4)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 4 Pull Box 400 A 16.38 (416.1) 44.88 (1140.0) 7.88 (200.2) 8.00 (203.2) 45.75 (1162.1) 28.63 (727.2)(2) 4.00 101.6 5 800 A 24.38 (619.3) 46.88 (1190.8) 11.88 (301.8) 12.00 (304.8) 47.75 (1212.9) 32.25 (819.2)(3) 4.00 101.6 6 1200 A 32.50 (825.5) 56.88 (1444.8) 12.00 (304.8) 17.75 (450.9) 57.75 (1466.9) 42.25 (1073.2)(4) 5.00 127.0 7 EUSERC Bussed Pull Section Single-phase 400 and 800 A 20.13 (511.3) 61.00 (1549.4) 11.25 (285.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 5 Three-phase 400 and 800 A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 6 EUSERC Main Terminal Box Single-phase 400 and 800 A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (2) 12.7, 19.1, 25.4 2 Three-phase 400 A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Three-phase 800 A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-111 4 4.10Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breakers, Terminal Boxes and Pull Boxes Top Feed Fusible Switch Bottom Feed Fusible Switch and Combination Fusible Switch with Pull Box Bolted Pressure Switch EUSERC Main Terminal Box C B A E D Main CB, Non-Euserc Terminal Box and Pullboxes F C 17.00 (431.8) A E B D Top Feed Switch (No Knockouts) F Bottom Feed Switch and Combination Switch/Pullbox A E B D C 17.00 (431.8) F D BE A 25.00 (635.0) F C A B C V1-T4-112 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) Knockout 1 Knockout 2 Knockout 3 Knockout 4 .875 .020 .169+.003–.000 Diameter 5 Hole .175.010 Stamped ID Mark 5.375 .010 3.500 .010 2.880.010 KO (44) KO (1) 12.375 .010 3.010.010 2.880.030 2-1/2”, 3”, 3-1/2”, 4” KO 1 Knockout Required 1/2”Knockout 1 Required Per 50-1827-1 .080.0202.500 .020 .310 .030 Diameter Paint Hole.080 .020 .438.010 .800.030 .625 .010 6.500 Outside .010CL 8.00 2 Knockouts for 1/2”, 3/4” or 1” Conduit 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .281 Diameter Knockout1 Required A .45 3.25 2.50 1.75 4.25 .16 22.54 11.62 10.382.50 3.75 1.93 .61 19.40 8.00 4.00 11.19 2.125.020 6.000.010 6.000.0106.000.010 6.000.010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 3/4”, 1”, 1-1/4”, 1-1/2” KnockoutPer A50-26319 1 Knockout Required 32.120 .020 3”, 3-1/2”, 4”, 5” Knockout Per A50-263275 Knockouts Required .380 .020 2.750 .010 2.750.010 2.750 .010 4.000.020 7.500 .020 2.125.020 1.440 .020 .169 .002 Diameter5 Holes Required at ”X” 1.500.020 .130 .030 .125 .030 4.440.020 8.00 22.54 11.62 10.382.50 19.40 8.00 4.00 3.75 1.93 .61 11.19 .45 3.25 2.50 1.75 4.25 2 Knockouts for 1/2”, 3/4” or 1” Conduit 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .281 Diameter Knockout1 Required .16 B Knockout 5 Knockout 6 Knockout 7 Knockout 8 6.000 .020 KO (10) KO (10) 5.000 .020 .150 .020Typ.3.250 .020 3.000.020 .150 .020 Typ. 6.120 .020 6.850.020 7.000+.000–.030 .780 .020 Typ. .200 .020 Typ. KO (10) .150 .020Typ. KO (10) KO (10) 6.000 .0206.000.0206.000.020 .250 Ref. .150.020 Typ. 4.000.020 4.250.020 .250 Ref. .220Dia. Paint Hole 10.120.020 10.850 .020 11.000+.000 -.030 .200 .020Typ..780 .020 Typ. 7.250.020 7.250.020 7.250 .020 5.125.020 .350Ref. .150.020Typ. 4.000.020 4.250.020 .350Ref. .220Dia.Paint Hole .150 .020Typ. KO (11) KO (11) KO (11) KO (11) 10.140.020 10.850 .020 11.000+.000–.030 .120.020Typ..685 .020Typ. 4 Knockouts for 2-1/2", 3", 3-1/2" or 4" Conduit 8.00 4.00 8.00 24.38 11.251.75 2.13 15.38 3.75 16.63 27.13 2.50 3.63 0.50 4.75 3.13 2.50 1.50 4.25 1.75 .281 Dia. Knockout 1 Required 2 Knockouts for 1/2", 3/4", or 1" Conduit 2 Knockouts for 1/2", 3/4", or 1" Conduit Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-113 4 4.10Metering Products Group Metering Approximate Dimensions in Inches (mm) Layout—Main Fusible Switch V1-T4-114 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breaker—“T-Opposite” Phasing Right Main Circuit Breaker—“T-Opposite” Phasing Left Main Circuit Breaker—“Standard T” Phasing Right Main Circuit Breaker—“Standard T” Phasing Left Meter Center Front CL Horizontal CL Floor Wall Vertical 8.48 (215.4) 38.76 (984.5) 18.17 (461.5) 20.00 (508.0) 30.08 (764.0)T-OppositeT-OppositeT-OppositeT-Opposite6.00 (152.4) Meter Center Front CLHorizontal 20.00 (508.0) Floor Wall CLVertical 38.76 (984.5) 18.17 (461.5) 30.08 (764.0) 8.48 (215.4)T-OppositeT-OppositeT-OppositeT-Opposite6.00 (152.4) Meter Center Front CLHorizontal CL 20.00 (508.0) Floor Wall Vertical 8.48 (215.4) 38.76 (984.5) 18.17 (461.5) 30.08 (764.0) 6.00 (152.4) Meter Center Front CLHorizontal CL 38.76 (984.5) 18.17 (461.5) 20.00 (508.0) 30.08 (764.0) Floor 8.48 (215.4)Wall Vertical 6.00 (152.4) V1-T4-104 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Main Circuit Breaker ●Phase and neutral lugs included. If additional neutral lugs are needed, order 1MCB1200NLK for (3) 1/0–750 or (6) 1/0–300 kcmil ●For shunt trip mains, order the field-installable shunt trip kit in this volume, Tab 1, section 1.1 ●For overhead feed, use Myer type hub. Verify local utility approval ●For compression lugs on 400, 600, 800, 1000 and 1200 A units, add CL to the end of the part number (includes copper lug pads for lines and neutral) ●1200 A or greater main devices must be center fed when installing 800 A residential meter stacks ●1400, 1600 and 2000 A main devices must be center fed when installing 800 and 1200 A residential and commercial meter stacks Main Circuit Breaker Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Reference drawing EUSERC DWG-315. 3 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 4 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 5 Main devices with a rating greater than 800 A can be used with 800 A residential modular stacks, but only as a center fed main. Main Ampere Rating Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 2 250 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB250R 3MCB250R 250 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB250R 3MHCB250R 300 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB300R 3MCB300R 300 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB300R 3MHCB300R 350 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB350R 3MCB350R 350 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB350R 3MHCB350R 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB400R 3 3MCB400R 3 400 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB400R 3 3MHCB400R 3 500 LD Bottom/top 65 (2) 400–500 kcmil 1MCB500R 3MCB500R 500 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB500R 3MHCB500R 600 LD Bottom/top 65 (2) 400–500 kcmil 1MCB600R 3 3MCB600R 3 600 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB600R 3 3MHCB600R 3 700 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB700R 3MHCB700R 700 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB700R 3MCB700R 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800R 3 3MCB800R 3 800 MDL Bottom/top 65 (2) 500–750 kcmil 1MCB800R750 3MCB800R750 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800R 3 3MHCB800R 3 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB900R 5 3MCB900R 5 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB900R 5 3MHCB900R 5 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB1000R 35 3MCB1000R 35 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750 3MCB1000R750 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB1000R 35 3MHCB1000R 35 1200 NGS Bottom 65 (4) 4/0–500 kcmil 4 1MCB1200R 35 3MCB1200R 35 1200 NGH Bottom 100 (4) 4/0–500 kcmil 4 1MHCB1200R 35 3MHCB1200R 35 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750 Main Circuit Breaker Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-105 4 4.10Metering Products Group Metering Main Circuit Breaker Main Circuit Breaker, continued Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Reference drawing EUSERC DWG-315. 3 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 4 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 5 Main devices with a rating greater than 800 A can be used with 800 A residential modular stacks but only as a center fed main. 6 If (6) #2–600 kcmil lugs are needed, order TA2000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA2000N. 7 Copper bus. 8 Main devices with a rating greater than 1200 A can be used with residential and commercial modular metering stacks but only as a center fed main. 9 Only to be used in center feed applications with 1200 A meter stacks. Not to be used with 800 A stacks. Main Ampere Rating Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (EUSERC) 2 300 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE300R 3MCBE300R 350 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE350R 3MCBE350R 400 KD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE400R 3MCBE400R 400 HKD Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE400R 3MHCBE400R 500 LD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE500R 3MCBE500R 600 LD Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE600R 3MCBE600R 600 HLD Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE600R 3MHCBE600R 800 MDL Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE800R 3MCBE800R 800 HMDL Bottom/top 100 Crimp lug landing pads (no lugs included)1MHCBE800R 3MHCBE800R 1000 NGS Bottom/top 65 Crimp lug landing pads (no lugs included)1MCBE1000R 3MCBE1000R 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included)1MCBE1200R 3MCBE1200R 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MHCBE1200R 3MHCBE1200R Copper Bus (Premium Offering) 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0-500 kcmil 1MCB400RC 3 3MCB400RC 3 400 HKD Bottom/top 100 2/0–500 kcmil 1MHCB400RC 3 3MHCB400RC 3 600 LD Bottom/top 65 (2) 300–500 kcmil 1MCB600RC 3 3MCB600RC 3 600 HLD Bottom/top 100 (2) 300–500 kcmil 1MHCB600RC 3 3MHCB600RC 3 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800RC 3 3MCB800RC 3 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800RC 3 3MHCB800RC 3 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB900RC 5 3MCB900RC 5 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB900RC 5 3MHCB900RC 5 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750C 3MCB1000R750C 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 4 1MCB1000RC 35 3MCB1000RC 35 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 4 1MHCB1000RC 35 3MHCB1000RC 35 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750C 1200 NGS Bottom 65 (4) 4/0–500 kcmil 4 1MCB1200RC 35 3MCB1200RC 35 1200 NGH Bottom 100 (4) 4/0–500 kcmil 4 1MHCB1200RC 35 3MHCB1200RC 35 1400 RGH Bottom 100 (4) 500–1000 kcmil 6 1MCB1400RBC 57 3MCB1400RBC 57 1400 RGH Top 100 (4) 500–1000 kcmil 6 1MCB1400RT 8 3MCB1400RT 8 1600 RGH Bottom 100 (4) 500–1000 kcmil 6 1MCB1600RBC 78 3MCB1600RBC 78 1600 RGH Top 100 (4) 500–1000 kcmil 6 1MCB1600RT 8 3MCB1600RT 8 2000 RGH Bottom 100 (6) #2–600 kcmil 1MCB2000RBC 79 3MCB2000RBC 79 2000 RGH Top 100 (6) #2–600 kcmil 1MCB2000RT 9 3MCB2000RT 9 Copper Bus (EUSERC) 2 1000 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MCBE1000RC 3MCBE1000RC 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included)1MCBE1200RC 3MCBE1200RC 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included)1MHCBE1200RC 3MHCBE1200RC Main Circuit Breaker Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-129 4 4.10Metering Products Group Metering 35MM, 37MM, 35SS and 37SS Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS) Commercial Meter Stack Modules Product Description ●Heavy-duty lever bypass socket design ●Single-phase or three- phase designs (35 = single- phase, 37 = three-phase) ●Provision for two-pole or three-pole main tenant breakers ●Phase balance kits are included with three-high and four-high modules Features, Benefits and Functions A. End Walls The top cap is removable and does not contain knockouts, so contractors can position and punch holes where they need them. There are numerous KOs in the back and bottom for flexibility. B. Ground Bars The factory-installed equipment ground bars are provided in both the top and bottom gutters. C. Meter Socket The 5-jaw meter socket and 7-jaw meter socket includes a built-in manual bypass and jaw release. The ground wire is factory connected in both 35MM and 37MM modules. D. Separate Wireway Cover If work on the breakers or cables is necessary, it can be accomplished without disturbing the meters or meter covers, thanks to a separate cover that allows easy access to the module’s main tenant breaker and wireway section. (Not shown.) E. Barrier A solid metal barrier separates the meter socket section from the tenant breaker in the wireway section. The unmetered vertical bus is enclosed to guard against power theft. F. Neutral Assembly Located in the wireway of each module, the assembly permits convenient termination of the neutral conductors. G. Enclosed Horizontal Bus Non-removable metal barrier encloses 1200 A horizontal bus when passing through the tenant breaker section for added security. H. Tenant Breaker Range All modules accept 15–225 A bolt-on breakers in various AIC ratings. The CHH_X breaker carries a UL listed series rating of 100,000 A, which allows you to use standard 10 kAIC breakers in downstream loadcenters and panelboards by Eaton. I. Indoor/Outdoor Construction Raintight caps, meter covers and lockable raintight tenant breaker covers make it convenient for you to use any of our modules on either NEMA 1 or NEMA 3R applications. J. Mounting Rail Rear mounting rail and wall hanger speed and simplify installation. (Mounting rail not shown.) K. Nameplate and Ratings The nameplate gives you full rating data: 208Y/120, three- phase, four-wire; 240/120, three-phase, four-wire delta (high leg on B-phase); and 240/120 single-phase. (Not shown.) L. Mains and Modules Slip together quickly, smoothly with front- accessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. V1-T4-130 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering 37MM Meter Stack Module ●Eaton’s 35MM and 37MM modular metering stacks contain meter sockets with built-in manual bypass and jaw release (Non-EUSERC areas) ●Eaton’s 35SS and 37SS stacks use meter sockets with test bypass feature (meets EUSERC electrical requirements) ●All commercial modular metering stacks contain four horizontal cross buses ●Mechanically and electrically built to bolt-up with main service modules and residential modular metering stacks Catalog Number Selection Commercial Meter Stack Modules When Ordering: 1. Determine catalog number of Main Service Module. 2. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T4-136). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T4-138 and V1-T4-139. L B G F E H C I A Phases Three-phase only Number of Jaws 5 or 7 Socket Amperage 20 = 200 A 40 = 400 A Number of Meters 1, 2, 3 or 4 Socket Type K = K Base bolt-on socket Blank = Plug-in type socket Type of Metering MM = Commercial metering module SS = Safety socket—EUSERC Bus 12 = 1200 A main bus ampacity AB = Phases A&B—EUSERC AC = Phases A&C—EUSERC BC = Phases B&C—EUSERC Enclosure R = NEMA 3R Tenant Breakers 40 = 400 A included Blank = Ordered separately Bus C = Copper Blank = Aluminum 3 7 MM 1 40 R 12 40 K C Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-131 4 4.10Metering Products Group Metering Product Selection 35MM ●Each socket is a 5 terminal block with lever bypass and jaw release ●Ringless covers ●Provision for two-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T4-136 ●Phase balancing kits are included with three-high and four-high modules. Each individual socket can be phase balanced in the field to the desired lines (A-B, B-C or A-C). Comes from factory as A-B ●Indoor/outdoor construction ●Main tenant feeders can exit top, bottom or back ●If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ●Short-circuit ratings up to 100 A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device ●Non-EUSERC areas 35MM—Single-Phase Commercial Meter Stack Modules (Three-Phase In, Single-Phase Out) Notes 1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 2 Unit is bottom exit only. 3 Rated at 100 kAIC. 4 Rated at 35 kAIC. System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket Main Tenant Breaker Type (Page V1-T4-136) 1 Catalog Number 120/240 V, single-phase, three-wire systems and 208Y/120 V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 35MM120R12 1 1200 Cu 5 35MM120R12C 2 1200 Al 5 35MM220R12 2 1200 Cu 5 35MM220R12C 3 1200 Al 5 35MM320R12 3 1200 Cu 5 35MM320R12C 4 1200 Al 5 35MM420R12 4 1200 Cu 5 35MM420R12C 400 1 1200 Al 5 400 A K-Frame included 35MM140R1240 2 1 1200 Cu 5 35MM140R1240C 2 400 1 1200 Al 5 400 A K-Frame included 35MM140HR1240 3 1 1200 Cu 5 35MM140HR1240C 3 400 2 1200 Al 5 400 A K-Frame included 35MM240R1240 2 1200 Cu 5 35MM240R1240C 400 continuous 1 1200 Cu 5 400 A L-Frame included 35MM140R1240K 400 continuous 1 1200 Cu 5 400 A L-Frame included 35MM140HR1240KC 4 V1-T4-132 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering 37MM ●Each socket is a 7 terminal block with lever bypass and jaw release ●Ringless covers ●Provision for three-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T4-136 ●Indoor/outdoor construction ●Main tenant breakers can exit top, bottom or back ●If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ●Short-circuit ratings up to 100 A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device ●Non-EUSERC areas 37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out) Notes 1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase. 2 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 3 320 A continuous rated socket with provisions for two main tenant breakers. 4 Unit is bottom exit only. 5 Rated at 100 kAIC. 6 Rated at 25 kAIC. 7 Rated at 35 kAIC. System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket 1 Main Tenant Breaker Type 2 (Page V1-T4-136) Catalog Number 208Y/120 V, three-phase, four-wire 240/120 V, three-phase, four-wire delta (B-phase is high leg) 225 1 1200 Al 7 Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X 37MM120R12 1 1200 Cu 7 37MM120R12C 2 1200 Al 7 37MM220R12 2 1200 Cu 7 37MM220R12C 3 1200 Al 7 37MM320R12 3 1200 Cu 7 37MM320R12C 4 1200 Al 7 37MM420R12 4 1200 Cu 7 37MM420R12C 400 1 1200 Al 7 Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X 37MM140R123 1 1200 Cu 7 37MM140R12C 3 400 1 1200 Al 7 400 A K-Frame included 37MM140R12404 1 1200 Cu 7 37MM140R1240C4 400 1 1200 Al 7 400 A K-Frame included 37MM140HR1240 5 1 1200 Cu 7 37MM140HR1240C5 400 2 1200 Al 7 400 A K-Frame included 37MM240R1240 2 1200 Cu 7 37MM240R1240C 400 continuous 1 1200 Cu 7 400 A L-Frame included 37MM140R1240KC 6 400 continuous 1 1200 Cu 7 400 A L-Frame included 37MM140HR1240KC7 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-133 4 4.10Metering Products Group Metering 35SS ●Sockets include EUSERC required test-bypass- disconnect feature ●Ring type covers ●Single-phase units have provisions for two-pole main tenant breakers ●When applying 35SS (single-phase) stacks on 208Y/120 V, three-phase, four-wire and 240/120 V, three-phase, four-wire delta systems, refer to suffixes for proper phase balancing. Each meter stack module is phase balanced at the plant (A-B, B-C or A-C) and cannot be field modified ●Indoor/outdoor construction ●Main tenant breakers can exit top, bottom or back. If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ●Short-circuit ratings up to 100 A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device 35SS—Three-Phase Commercial Meter Stack Modules 1 37SS ●Sockets include EUSERC required test-bypass- disconnect feature ●Ring type covers ●Three-phase units have provisions for three-pole main tenant breaker ●Aluminum horizontal bus supplied as standard 37SS—Three-Phase Commercial Meter Stack Modules 1 Notes 1 Reference drawing EUSERC DWG-304 for 100 A; Reference drawing EUSERC DWG-305 for 200 A. 2 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 3 Last two digits of catalog number indicate phase balancing (AB indicates all sockets in this stack are connected to phases A and B only). System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket Main Tenant Breaker Type 2 (Page V1-T4-136) Catalog Number 120/240 V, single-phase, three-wire systems and 208Y/120 V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_X CV2_X CVH2_X 35SS120RAB 3 1200 Cu 5 35SS120RABC 3 1200 Al 5 35SS120RAC 3 1200 Cu 5 35SS120RACC 3 1200 Al 5 35SS120RBC 3 1200 Cu 5 35SS120RBCC 3 2 1200 Al 5 35SS220RAB 3 1200 Cu 5 35SS220RABC 3 1200 Al 5 35SS220RAC 3 1200 Cu 5 35SS220RACC 3 1200 Al 5 35SS220RBC 3 1200 Cu 5 35SS220RBCC 3 3 1200 Al 5 35SS320RAB 3 1200 Cu 5 35SS320RABC 3 1200 Al 5 35SS320RAC 3 1200 Cu 5 35SS320RACC 3 1200 Al 5 35SS320RBC 3 1200 Cu 5 35SS320RBCC 3 35SS_ System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket Main Tenant Breaker Type 2 (Page V1-T4-136) Catalog Number 208Y/120 V, three-phase, four-wire 240/120 V, three-phase, four-wire delta (B-phase is high leg) 225 1 1200 Al 7 Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X 37SS120R 1200 Cu 7 37SS120RC 2 1200 Al 7 37SS220R 1200 Cu 7 37SS220RC 3 1200 Al 7 37SS320R 1200 Cu 7 37SS320RC V1-T4-134 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) Commercial Stacks (35MM and 37MM) 35MM and 37MM 19.25 (489.0) 66.63 (1692.3)25.38 (644.5) 14.00 (355.6) Typ. 52.63 (1336.7) 52.63 (1336.7) 8.75 (222.3) 35MM140R1240 37MM140R1240 same as below except eliminate top socket. 18.25 (463.6) 8.75 (222.3) 18.25 (463.6) 8.75 (222.3) 18.25 (463.6) 8.75 (222.3) Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-135 4 4.10Metering Products Group Metering Approximate Dimensions in Inches (mm) Commercial Stacks (35SS and 37SS) 35SS and 37SS 3 KOs 1.50 (38.1), 2.00 (50.8), 2.50 (63.5) Bottom (Typ.) 13.56 (344.5) 8.75 (222.3) Inside Wire Seal Slot and Sealing Screw Ribbon Seal or Barrel Lock Hasp 21.38 (542.9) 12.00 (304.8) 29.38 (746.1) 25.00 (635.0) 13.50 (342.9) 6.50 (165.1) KO 1.50 (38.1) 2.00 (50.8), 2.50 (63.5) 9.50 (241.3) 17.75 (450.9) Centerline of Wall Mounting Screws 47.38 (1203.3) 19.50 (495.3) 21.38 (542.9) 12.00 (304.8) 6.50 (165.1) 31.50 (800.1) 43.00 (1092.2) 9.56 (242.9) 19.50 (495.3) 19.50 (495.3) 68.88 (1749.4) 6.50 (165.1) 62.44 (1585.9) 31.50 (800.1) 0.41 Dia. (10.3) 4-Holes 9.56 (242.9) 12.00 (304.8) 21.38 (542.9) V1-T4-136 Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com 4 4.10 Metering Products Group Metering CV2200/CV3200 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Product Description ●The following breakers are to be used on 35MM, 37MM, 35SS and 37SS modular metering stacks ●Series rating information available on Pages V1-T4- 144 through V1-T4-147 ●Two-pole breakers are 120/240 Vac, field installed ●Three-pole breakers are 208Y/120 Vac, field installed Volume 1—Residential and Light Commercial CA08100002E—February 2016 www.eaton.com V1-T4-137 4 4.10Metering Products Group Metering Product Selection 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Notes 1 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK (two-pole) 3TA225CVK (three-pole). One kit is needed per breaker. 2 “MM” suffix provides mounting hardware needed for 1MP, 1MM and 3MM modular metering stacks only. Mounting hardware is not needed for use in 35MM and 35SS modular metering stacks, but is included as standard with breakers. 3 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 4 Type EHD main tenant circuit breakers are also available from 15 to 50 A. 10 kAIC 25 kAIC 42 kAIC 65 kAIC 100 kAIC Description Number of Poles Main Tenant Circuit Breaker Ampere Rating Catalog Number Catalog Number 12 Catalog Number 12 Catalog Number 12 Catalog Number 12 Bolt-On Type Bolt-on type circuit breakers used with 35MM and 35SS (single-phase modular metering stacks) 34 260 CCV2060X CCVH2060X CVS2060XMM CV2060XMM CVH2060XMM 270 CCV2070X CCVH2070X CVS2070XMM CV2070XMM CVH2070XMM 280 CCV2080X CCVH2080X CVS2080XMM CV2080XMM CVH2080XMM 290 CCV2090X CCVH2090X CVS2090XMM CV2090XMM CVH2090XMM 2100 CCV2100X CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2125 CCV2125X CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 2150 CCV2150X CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2175 CCV2175X CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 2200 CCV2200X CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM 2225 CCV2225X CCVH2225X CVS2225XMM CV2225XMM CVH2225XMM Bolt-On Type Bolt-on type circuit breakers used with 37MM and 37SS (three-phase modular metering stacks) 34 360 EHD3060 CVS3060X CVS3060X CV3060X CVH3060X 370 EHD3070 CVS3070X CVS3070X CV3070X CVH3070X 380 EHD3080 CVS3080X CVS3080X CV3080X CVH3080X 390 EHD3090 CVS3090X CVS3090X CV3090X CVH3090X 3100 CC3100X CVS3100X CVS3100X CV3100X CVH3100X 3125 CC3125X CVS3125X CVS3125X CV3125X CVH3125X 3150 CC3150X CVS3150X CVS3150X CV3150X CVH3150X 3175 CC3175X CVS3175X CVS3175X CV3175X CVH3175X 3200 CC3200X CVS3200X CVS3200X CV3200X CVH3200X 3225 CC3225X CVS3225X CVS3225X CV3225X CVH3225X Detail Bill of Material Page 1 of 1 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Item No. Qty Product Description 2 Safety Switches Safety Switches Catalog No DG325FGK Designation GEN DISC SW Qty List of Materials 1 General Duty Switch - Fusible, 3-Pole, 240 VAC, 400 A, NEMA 1 Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction thereof for the time the shipment is delayed. Safety Switch General Information Global Specifications System Voltage 240 VAC Switch Type Single Throw -General Duty Poles/Blades 3-Pole Amperage 400 Protection Fusible with No Neutral Enclosure Type NEMA 1 Fuse Clips Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Fuse Pullers N Control Pole N Ground Lugs Standard Stainless Mechanism N Mill Duty N Nameplate Safety Switch Catalog No. DG325FGK NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. B1S91001X9K1-0001 JULIO VELEZ 11/5/2019 1.0.0.1 0 A Eaton OXOBOXO LOFTS GEN DISC SW Safety Switch General Information Customer Appr. 1 of 1 Date PDF Generated:9/25/2012 Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS DG325FGK GEN DISC SW Volume 2—Commercial Distribution CA08100003E—February 2018 www.eaton.com V2-T1-25 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1Switching Devices Safety Switches Cartridge Fuse General-Duty Safety Switch General Duty Product Description ●30–600A ●Suitable for service entrance applications unless otherwise noted ●Fusible and non-fusible switches are 100% load break and 100% load make rated ●The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated ●200–600A features K-Series design ●Horsepower rated ●Fusible and non-fusible switches. Single-pole S/N through four-wire; 120/240, and 240 Vac ●With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated. ●Bolt-on hub provision. Provided for general-duty switches in a NEMA 3R enclosure. See Page V2-T1- 14 for selection Application Description For residential and commercial applications. Suitable for light-duty motor circuits and service entrance. Features, Benefits and Functions General-Duty (Cartridge Fuse) ●Ample wire bending space provides for easier installation ●Visible double-break quick- make, quick-break rotary blade mechanism ●Side opening door on all enclosures ●Mechanically interlocked cover to prevent easy access when the switch is in the ON position ●With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical ●Clearly visible and accessible neutral where applicable ●Visible ON/OFF indication ●Tangential knockouts on 30–60A designs ●Ample wiring space ●Double padlocking capability on 30–100A ●Triple padlocking capability on 200–600A ●Additional door locking capability ●Bilingual English/Spanish door label on 30–100A ●Tri-lingual nameplates V2-T1-26 Volume 2—Commercial Distribution CA08100003E—February 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. ●Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism ●Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 V2-T1-16 Volume 2—Commercial Distribution CA08100003E—February 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1 Switching Devices Safety Switches Technical Data and Specifications Standard Lug Capacities Notes 1 The maximum size aluminum or copper-clad wire allowable for applications where the conductor enters or leaves the enclosure through the wall opposite its terminal is #1 gauge. 2 Applicable to DG/DH non-fused NEMA 1 and 3R only. The maximum size wire allowable for applications where the conductor enters or leaves the enclosure through the wall opposite its terminal is 250 kcmil. 3 Single barrel lug that accepts one or two cables per phase as detailed above. 4 Double barrel lug that accepts 2 cables per phase as detailed above. 5 No Copper-Bodied Lugs are available for 1200A switches. No Copper-Bodied Lugs are available for larger than 500 kcmil cables. No Copper-Bodied Lugs are available for 400–800A NEMA 1 or NEMA 3R switches. Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in NEC®. A factory-installed ground lug is supplied in all heavy-duty safety switches. Description Minimum Wire Size Maximum Wire Size Wire Type 30A DP #14 #10 CU #12 #10 AL 30A DG #14 #6 CU/AL 30A DH, DT #14 #2 CU/AL 60A DG #14 #1/0 CU/AL 60A DH, DT #14 #2 CU/AL 100A DG 1 #14 #1/0 CU/AL 100A DH, DT #14 #1/0 CU/AL 200A DG, DT #6 250 kcmil CU/AL 200A DH Type 1 and 3R #6 250 kcmil CU/AL 200A DH Type 4X and 12 #6 300 kcmil CU/AL 400A DG, DH, DT 2 (2) #1/0 (2) 300 kcmil CU/AL or 3 (1) #1/0 (1) 750 kcmil CU/AL 600A DG, DH (1) #2 (1) 600 kcmil CU/AL and 4 (1) #1/0 (1) 750 kcmil CU/AL 600A non-fusible DT (2) 250 (2) 500 kcmil CU/AL 800A DH (4) #1/0 (4) 750 kcmil CU/AL 600A fusible DT, 800A DT (3) #250 (3) 500 kcmil CU/AL 1200A DH, DT (4) #1/0 (4) 750 kcmil CU/AL Copper-Bodied Lugs 5 30A CU #14 #6 CU 60A CU #14 #4 CU 100A CU #6 #1/0 CU 200A CU #6 250 kcmil CU 400A CU Type 4, 4X, and 12 #1/0 500 kcmil CU 600-800A CU Type 4, 4X and 12 (2) #1/0 (2) 500 kcmil CU Volume 2—Commercial Distribution CA08100003E—February 2018 www.eaton.com V2-T1-11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1Switching Devices Safety Switches Catalog Number Selection General-Duty Heavy-Duty Notes 1 For DC ratings, check individual switch ratings. 2 Only available for 400A and higher safety switches. 3 See Modifications-Flex Center for additional available options. 4 All window switches feature enhanced visible blade design as standard. 5 Only available in NEMA 12/3R and NEMA 4X enclosures. 6 Only available in 200 to 1200A NEMA 12/3R and NEMA 4X enclosures. These tables are intended for use in breaking down existing catalog numbers. They are not intended for building new catalog numbers. A factory-installed ground lug is supplied in all heavy-duty safety switches. Series B = Design general-duty 30–100A K = Design for general duty 200A and higher NEMA Enclosure Ratings G = NEMA 1 R = NEMA 3R Switch Type DG = General-duty/cartridge fuse DP = General-duty/plug fuse Voltage 2 = 240 Vac Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A Poles/Blades 1 = 1-pole 2 = 2-pole 3 = 3-pole DG 3 2 1 N G B Protection F = Fusible without neutral U = Non-fusible N = Fusible with neutral Series K = Design all heavy-duty Protection F = Fusible without neutral U = Non-fusible N = Fusible with neutral NEMA Enclosure Ratings G = NEMA 1 R = NEMA 3R D = NEMA 12 or 12/3R P = NEMA 4 2 W = NEMA 4X (corrosion-resistant (304 Grade stainless steel) C = NEMA 4X non-metallic (for Type DH) X = NEMA 7/9 (for Type DS) Switch Type DH = Heavy-duty DS = Classified location with DS interior Voltage 1 2 = 240 Vac 6 = 600 Vac Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A 7 = 800A 8 = 1200A Options 3 W= Viewing window 45 V= Enhanced visible blade X= Stainless steel mechanism LW = Lower viewing window 6 GCL= Mill duty rated Poles/Blades 1 = 1-pole 2 = 2-pole 3 = 3-pole 4 = 4-pole 6 = 6-pole DH 3 6 4 U D K W V2-T1-12 Volume 2—Commercial Distribution CA08100003E—February 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1 Switching Devices Safety Switches Double-Throw Notes 1 For DC ratings, check individual switch ratings. 2 Only available for 400A and higher safety switches. 3 See Modifications-Flex Center for additional available options. 4 All window switches feature enhanced visible blade design as standard. 5 Only available in NEMA 12/3R and NEMA 4X enclosures. These tables are intended for use in breaking down existing catalog numbers. They are not intended for building new catalog numbers. A factory-installed ground lug is supplied in all heavy-duty safety switches. Series K = Design all heavy-duty H= General-duty double-throw switch (compact design 30–100A)Protection F = Fusible without neutral U = Non-fusible N = Fusible with neutral NEMA Enclosure Ratings G = NEMA 1 R = NEMA 3R D = NEMA 12 or 12/3R P = NEMA 4 2 W = NEMA 4X (corrosion-resistant (304 Grade stainless steel) Switch Type DT = Double-throw Voltage 1 2 = 240 Vac 6 = 600 Vac Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A 7 = 800A 8 = 1200A Options 3 W = Viewing window 45 V = Enhanced visible blade X = Stainless steel mechanism Poles/Blades 2 = 2-pole 3 = 3-pole 4 = 4-pole 6 = 6-pole DT 3 6 5 N D K W Detail Bill of Material Page 1 of 1 Project Name: OXOBOXO LOFTS Negotiation No: B1S91001X9K1 General Order No: Alternate No: 0001 11/05/2019 10:25 AM Item No. Qty Product Description 73 Loadcenters BR PON LOADCENTER, 100A, MAIN BREAKER, 30 SPACE, C Catalog No BRP30BC100 Designation BLDG L Catalog No Qty List of Materials BRP30BC100 1 BR PON LOADCENTER, 100A, MAIN BREAKER, 30 SPACE, C BR220 2 Type BR Breaker 20A/2 Pole 120/240V 10K BR120 3 Type BR Breaker 20A/1 Pole 120/240V 10k BRP120DF 4 BR DUAL FUNCTION AF/GF 1P 20A BRP120AF 5 BR COMBO AFCI, 1P, 20A, 10KAIC, PLUG-ON NEUTRAL Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction thereof for the time the shipment is delayed. 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVEPROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2018 211=6 INCHES 0398-1185 2018/06/19M.S.BR 1" LOADCENTER, BR MAIN BREAKER, INDOOR NEMA 1, 120/240 VAC, 1 PHASE TYPE BR LOADCENTER RATINGS: Enclosure: Indoor NEMA 1 Incoming Main: Type BR Main Breaker Loadcenter Electrical Rating: 120/240 VAC, Single Phase Loadcenter Ampere: 125 Amps Max - See Main Breaker Rating Number of Spaces & Circuits: See Table on Page 2 Incoming Wire Range: See Table on Page 2 Bus Bar Material: Tin Plated Aluminum (Standard) or Copper Trim Type: Combination (Standard) Trim Paint: ANSI 61 Light Gray Short Circuit Rating: See Branch Breaker Ratings Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2) FEATURES: Plastic Backpan - For Plug-On Neutral Branch Breakers. Single keyhole mounting - One keyhole at top and bottom for mounting and leveling. Inboard Neutral Bar Assembly - For better management of load wires. Drywall Tabs on Enclosure - Sets mounting depth for flush applications. Top or bottom feed - Acceptable for either top or or bottom applications. Warranty - 10 year limited warranty on all BR Loadcenters and Breakers. OPTIONAL ACCESSORIES: Catalog Number Description GBKP5 5 POS #14-4 Ground Bar GBKP10 10 POS #14-4 Ground Bar GBKP14 14 POS #14-4 Ground Bar GBKP21 21 POS #14-4 Ground Bar NL20 Neutral/Ground Lug #2/0 max NLP20 Neutral/Ground Lug #2/0 max w/Bonding Tab BRPFP 1" Filler Plate BRPHD Hold-down kit for Type BR breaker BRPMIKBR Generator Interlock Kit 14.3 3.9 "A" Page: 1 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS BRP30BC100 BLDG L LOADCENTER DETAILS Catalog #Dim "A"Main Brkr Amps Spaces / Circuits Bus Material Bus Bar Amps Max. Wire Size Range ƵͬůϲϬΣŽƌϳϱΣNotes BRP10B100 16.75 100 10/20 Alum.125 #4-1/0 BRP10B100P1 16.75 100 10/20 Alum.125 #4-1/0 BRP10B100WP1 16.75 100 10/20 Alum.125 #4-1/0 BRP12B100 18.75 100 12/24 Alum.125 #4-1/0 BRP12B100WP1 18.75 100 12/24 Alum.125 #4-1/0 BRP12H100 18.75 100 12/24 Alum.125 #4-1/0 22 kAIC Rated Main Breaker BRP16B100 21 100 16/32 Alum.125 #4-1/0 BRP16B125 21 125 16/32 Alum.125 #4-2/0 BRP20B100 23 100 20/40 Alum.125 #4-1/0 BRP20B100V25 23 100 20/40 Alum.125 #4-1/0 BRP20BC100 23 100 20/40 Cu.125 #4-1/0 BRP20H100 23 100 20/40 Alum.125 #4-1/0 22 kAIC Rated Main Breaker BRP20H100V25 23 100 20/40 Alum.125 #4-1/0 22 kAIC Rated Main Breaker BRP20HC100 23 100 20/40 Cu.125 #4-1/0 22 kAIC Rated Main Breaker BRP20B125 23 125 20/40 Alum.125 #4-2/0 BRP30B100 29.12 100 30/60 Alum.125 #4-1/0 BRP30B100V25 29.12 100 30/60 Alum.125 #4-1/0 BRP30BC100 29.12 100 30/60 Cu.125 #4-1/0 BRP30H100V25 29.12 100 30/60 Alum.125 #4-1/0 22 kAIC Rated Main Breaker BRP30HC100 29.12 100 30/60 Cu.125 #4-1/0 22 kAIC Rated Main Breaker BRP30B125 29.12 125 30/60 Alum.125 #4-2/0 BRP30BC125 29.12 125 30/60 Cu.125 #4-2/0 Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to the following: S, F, W, G, K, L, M, N, P and #s, DG, V and #s. Contact sales for those specific details when necessary. 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVEPROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2018 221=6 INCHES 0398-1185 2018/06/19M.S.BR 1" LOADCENTER, BR MAIN BREAKER, INDOOR NEMA 1, 120/240 VAC, 1 PHASE Page: 2 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: B1S91001X9K1-0001-11/5/2019 OXOBOXO LOFTS BRP30BC100 BLDG L V1-T1-46 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Contents Description Page Overview Standards and Certifications. . . . . . . . . . . . . . .V1-T1-47 Catalog Number Selection . . . . . . . . . . . . . . . .V1-T1-49 Product Selection . . . . . . . . . . . . . . . . . . . . . . .V1-T1-51 BR Plug-on Neutral Loadcenters . . . . . . . . . . .V1-T1-58 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-61 Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-62 Type BR Renovation Loadcenter. . . . . . . . . . . .V1-T1-63 BR Loadcenter Options and Accessories. . . . . . . .V1-T1-66 BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-83 Overview General Product Description Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Plug-on Neutral Loadcenters The BR Plug-on Neutral portfolio from Eaton offers a unique design that offers improved safety, ease of installation and leaves the end result with a clean and professional look and feel. Features, Benefits and Functions Plug-on Neutral Style Loadcenters ●The short-body BR electronic circuit breakers are optimized to save gutter space and installation time with an easier, more succinct installation process ●Unique self-leveling tabs to allow for quick drywall offset ●Added keyhole hanging feature on cover for ease of installation ●Common drive types on screw connections for added simplicity and convenience ●Inboard neutral to increase the gutter space for easier installation of conductors ●Backed-out neutral screws to allow for a quick connection of ground and neutral conductors ●Upgraded to embossed circuit numbers for a more clean and professional look Loadcenter Construction Eaton’s Type BR loadcenters have standard tin-plated aluminum bus with a limited availability of copper bus. The sum of the handle ratings connected to any stab is limited to 150 A maximum on the 100 and 125 A loadcenters, and 200 A on loadcenters with 150 A or higher main bus. NEMA Type 1 boxes or enclosures are manufactured from galvanized steel. Raintight boxes are manufactured from galvanized steel, then finished using an electrostatic powder coat, baked urethane paint process. Neutrals Eaton BR loadcenters feature three types of neutrals: Inboard Plug-on Neutral Code changes and higher safety standards are leading to more arc fault circuit interrupter (AFCI) installations. With the electrical contractor in mind, Eaton has revolutionized the way Combination AFCIs are installed with the Plug-on Neutral line of loadcenters and breakers. Insulated/Bondable Split Neutral Panels are supplied with split insulated neutrals with an insulated cross strap. For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel. For non-service entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Insulated/Bondable Single Neutral Panels are supplied with a single insulated neutral. For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and re- tighten both connections. The single neutral can be moved by the contractor to the other side of the panel, if desired. When used as a service entrance panel, unused neutral connections may be used for the termination of equipment grounds. For non- service entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-47 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Grounds In service entrance applications where the neutral is bonded, unused neutral holes may be used for terminating ground conductors. In sub-feed panels, the neutral must be isolated (non-bonded), and ground wires must be terminated on a separate ground bar. The insulated/bondable single/split neutral panels have sufficient terminations for both ground and neutral conductors. The insulated/ bondable single split neutral panels are supplied with a separate factory-installed ground bar if the catalog number contains a “G.” If not, a separate ground bar should be installed. Insulated/ Bondable Single Neutral panels are supplied without a ground bar (unless otherwise noted), and ground bar kits if needed must be purchased separately. Neutral and Ground Terminals The standard terminals on grounds and neutrals are rated to accept (3) #14–#10 Cu/Al or (1) #14–4, provided the cables terminated are of the same material. For larger cables, add-on neutral lugs may be ordered from the accessories on Page V1-T1-72. Note: NEC allows only one current-carrying conductor per hole on neutrals unless otherwise noted. Bottom Fed Loadcenters For single-phase 225 A and below loadcenters that are bottom fed, a standard panel can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC 2008 Article 240.81. Gutter Splicing Loadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted. Refer to NEC 2008 Article 312.8. Fire Rating Due to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There is no approved method for sealing the enclosures for this application. Date Code The date of manufacture of each loadcenter is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the loadcenter, the date code is located on the small white label located on the right side wall (with the main device on top). The date code is in the following format: F # # # &. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacturing, e.g., 023. The “!” sign at the end signifies the decade of the 2010. Therefore, the date code F023& would indicate that the product was manufactured in the 23rd week of 2010. The 1980s are represented by the “+” sign and the 1990s are represented by a “=” at the end of the code. Surge Protectors Complete home surge protection is available in multiple options, including a factory-installed option that provides the highest level of surge protection in a residential design. See Tab 3 for more details. Circuit Breaker Case Interrupting Capacity ●10 kAIC ●22 kAIC ●25 kAIC Warranty Information ●10-year limited loadcenter warranty ●10-year limited branch breaker warranty Standards and Certifications UL Listings All Eaton Type BR loadcenters are listed under UL File E52977 except the 2–8 circuit loadcenters, up through and including 125 A, which are listed under UL File E8741. V1-T1-48 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenter Warranty 10-year warranty on all Type BR loadcenters and circuit breakers. Optimized Knockouts ■ ŁKnockout locations for additional access ■ ŁEasier to remove Smooth Case Edges ■ ŁProvides a more professional look and feel Top or Bottom Feed ■ ŁStraight-in wiring saves labor and material ■ ŁOne panel for either top or bottom applications Plug-On Neutral ■ ŁEliminates the pigtail connection providing time and labor savings ■ ŁProvides a professional installation 2/0 Lug ■ ŁEasily removable and can be installed in any location on the neutral bar Type BR AFCI Breakers ■ ŁCompact design for easier wiring improved wireway access ■ ŁOptional LED indicates one of six trip codes for circuit diagnostics ■ ŁProvides a clean gutter space Standard Tin-Plated Aluminum Bus ■ ŁExcellent conductivity and corrosion resistance ■ ŁCopper bus options available for select catalog numbers Inboard Neutral ■ ŁIncreases gutter space to allow for the professional installation of conductors Drywall Offset on Both Sides of the Enclosure ■ ŁAllow for faster installation using predetermined self-leveling tabs “Tangential” Center Knockout ■ ŁEasier installation for conduit applications Single Keyhole Mounting ■ ŁOne keyhole at the top and bottom provides easier mounting and leveling Backed Out Neutral Screws ■ ŁAllows for quick connection of neutral and ground conductors Twin Neutral Bars ■ ŁMinimum 150% neutral capacity Grounding Screw ■ ŁProvides a quick and easy means of bonding the neutral and ground Common Drive Types ■ ŁMinimizes number of tools required for installation as the neutral bar and breaker screws will share a common drive type Commercial Grade Main Breaker ■ Ł25 kAIC series rated main breaker for superior protection Cover Features not Shown: Cover Keyhole Hanging Feature ■ ŁEase of cover installation Rigid Center Cover Spine ■ ŁProvides strength when twistouts are removed Improved Cover Twist-Outs ■ ŁEasier to remove twistouts Embossed Cover Circuit Numbers ■ ŁDurable circuit numbering with added marking for twin breakers Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-49 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Catalog Number Selection Single-Phase Plug-on Neutral Loadcenters Single- and Three-Phase Legacy Loadcenters Note 1 No character space used. Type Designation BR = 1 inch (25.4 mm) breaker loadcenter BR P 30 L 200 G W P1 Packaging Blank = Individually packed with cover attached P1 = Loadcenters palletized (no box), covers 4 per carton Accessories Installed Blank = None installed DG = Double ground bar (for panels under 20 spaces) F = Feed-through lugs G = Ground bar Feature P = Plug-on neutral design 1 The number of circuits is equal to double the number of spaces. Number of Spaces 1 8 10 12 16 20 24 30 40 42 60 Bus Amperage 100 = 100 A 125 = 125 A 150 = 150 A 200 = 200 A 225 = 225 A Trim Color Blank = ANSI 61 Gray W = White (Indoor Only) Bus Material Blank = Aluminum C = Copper Main Device L = Main lug only B = Main breaker E = Convertible with main lugs installed N = Convertible (main device purchased separately) H =22 kAIC Enclosure Blank= NEMA Type 1 indoor with combination trim R = NEMA Type 3R rainproof S = NEMA Type 1 indoor with surface trim 3 BR 30 42 B C 200 Phase Blank = Single-phase 1 3 = Three-phase Construction Blank = No feed thru lugs 1 F = Feed-through lugs G = Ground bar P = Current design NY = NY City gutter space Number of 1-Inch (25.4 mm) Spaces Factory Options SUR = Factory integrated surge Eaton’s Type BR Loadcenter Maximum Number of Circuits Bus Blank = Aluminum bus 1 C = Copper bus Main Device B = Main breaker L = Main lug N = Convertible main H = Main breaker high AIC Enclosure R = NEMA Type 3R rainproof S = NEMA Type 1 indoor with surface trim F = NEMA Type 1 indoor with flush trim Blank = NEMA Type 1 indoor with combination trim 1 RIS = Riser panel Amperes 50 =50 A 70 =70 A 100 =100 A 125 =125 A 150 =150 A 200 = 200 A 225 = 225 A 300 = 300 A 400 = 400 A 600 = 600 A V1-T1-50 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Electronic Circuit Breakers Type Designation BR = 1 inch (25.4 mm) breaker loadcenter High kAIC Rating H =22 kAIC BR N 1 15 DF Options Blank =UL® C = Canada (CSA® only) Neutral Design N = Pigtail neutral wire P = Plug-on neutral Number of Poles 1 = Single-pole Amperes 15 = 15 A 20 = 20 A 25 = 25 A (GFI) 30 = 30 A (GFI) Breaker Function DF = Dual function AF = Combination arc fault GF = Ground fault EP = Equipment protection (30 mA) V1-T1-74 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Technical Data and Specifications General A. The Contractor shall furnish and install deadfront loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings. B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL, NEMA and NEC including: 1. UL 67—Standards for Panelboards. C. UL 50—Standards for Cabinets and Boxes. D. UL 489—Standards for Molded Case Circuit Breakers. E. UL 869—Standards for Service Equipment. F. Federal Specification W-C 375B—Circuit Breakers. G. Federal Specification W-C P115b—Panel Power Distribution Type 1, Class 2. Qualifications A. The manufacturer of the loadcenter shall be the manufacturer of the circuit breaker within the loadcenter. B. For the equipment specified herein, the manufacturer shall be ISO 9000 certified. C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years. Manufacturers A. Eaton. Ratings A. Loadcenters shall be rated for 120/240 Vac and shall have short-circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes rms symmetrical. B. Circuit breakers shall be a minimum of 125 A frame. Circuit breakers 15 through 125 A trip size shall take up the same pole spacing. C. Loadcenters shall be labeled with a UL short- circuit rating. When series combination ratings are applied with integral or remote upstream devices, a label shall be provided. Series combination ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including: 1. Size and type of upstream device. 2. Branch devices that can be used. 3. UL series short circuit rating. Construction A. All interiors, with the exception of the branch circuit breakers, shall be completely factory assembled with main breakers, main lugs, or no main device. B. Interiors shall be designed so that circuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be designed so that circuits may be changed without machining, drilling, or tapping. C. Physical means shall be provided to prevent the installation of more overcurrent devices than that number for which the enclosure was designed, rated and approved. Half-size breakers shall have a UL listed rejection tab over the line terminals. Loadcenter interiors must have notched stabs to accept these rejection tab class CTL breakers, if required and approved. Bus A. Busbars for the main and cross connectors shall be [tin-plated aluminum] [copper] in accordance with Underwriters Laboratories standards. Busing shall be braced throughout to conform to industry standard practice governing short-circuit stresses in loadcenters. Note: Note to spec writer— select one (copper available in limited ratings). B. Neutral busing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch. Wiring/Termination A. All wire connectors and terminals shall be of the anti-turn solderless type and shall be suitable for copper or aluminum wire of the sizes indicated. All connectors must meet the “Requirements for Wire Connectors and Soldering Lugs” as stated in UL 486B. B. All loadcenters where marked shall be suitable for use with 60 °C or 75 °C rated wire. Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-75 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Circuit Breakers A. Circuit breakers shall be molded case type. Circuit breakers shall have four-rivet construction (GFI Type— 5 rivets). Multipole circuit breakers shall be of a stack pole design to provide electrical phase isolation. B. Each pole of the circuit breaker will provide inverse time delay overload and instantaneous short- circuit protection by means of both thermal and magnetic sensors. C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. The thermal bimetal element shall be welded to the steel frame and calibration shall be set independent of the molded case by computer controlled equipment. D. All circuit breakers shall be operated by a toggle-type handle and multipole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mechanisms that are mechanically trip-free from the handle. The handle position shall provide visual trip indication. E. Contacts shall be of non-welding silver alloy. F. All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole. Also, unique color- coded cases that indicate the UL listed 10 kA or 22 kA interrupting ratings. Breakers shall be able to be used as main or branch disconnect devices. G. Branch circuit breakers may also be used in the 1/2-inch (12.7 mm) per pole ratings that include two-pole 1-inch (25.4 mm) wide modules and four-pole 2-inch (50.8 mm) wide modules. Two-pole circuit breakers must incorporate a common trip mechanism. H. Circuit breakers shall be completely enclosed in a molded case of thermoset material. No internal aluminum parts shall be used. All internal ferrous parts shall be plated to prevent corrosion. I. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug or clamp type design. The terminals shall meet UL 486B requirements and shall be suitable for use with either 60 °C or 75 °C wire. J. The calibrated bimetal assembly shall be mechanically isolated from the load terminal using a flexible braided copper shunt wire, such that movement of the terminals due to twisting and overtorquing does not affect breaker calibration. K. Breakers shall be SWD rated and/or HACR rated as required. L. Arc Fault Interrupting circuit breakers, (AFI), shall be provided on all 15 and 20 A single-phase 120/240 Vac circuits except those indicated as remote controlled breakers. AFI breakers shall be “Classified for mitigating the effects of arcing faults,” or conforming to UL Standard 1699 and as defined by Article 210.12 Section A of the 1999 NEC Code. Surge Protection Devices See Volume 1, Tab 2 for complete details on surge protection. Enclosures A. Loadcenter shall have NEMA Type 1 general purpose or NEMA Type 3R rainproof enclosures as indicated on the drawings and shall be surface or combination flush/surface mounted except where noted. B. Boxes shall be made from galvanized sheet steel having multiple knockouts. Rainproof boxes shall use galvanized steel or an approved coating system which meets or exceeds standards for outdoor NEMA Type 3R enclosures. Boxes shall be of sufficient size to provide at least a minimum code gutter space on all sides. C. The deadfront shall have an easy adjustment feature for flush applications. D. Boxes shall be factory assembled into a single rigid structure. E. Unless otherwise noted on drawings, hinged doors covering all circuit breaker handles shall be included in all trims. Trim doors shall not uncover any live parts in making the circuit breaker handles accessible. If key locks are required, all locks shall be keyed alike. F. Combination trims for flush and surface panels shall be flat and shall overlap the box by at least 5/8-inch (15.9 mm) all around. Trims shall be mounted by a screwdriver without the need for special tools. Finish A. Trims shall be bonderized and finished with a light gray ANSI-61 enamel. The paint finish shall be of a type to which field applied paint will adhere. Factory Testing A. The standard factory tests shall be performed on the equipment provided under this section. All tests shall be in accordance with the latest version of UL and NEMA. V1-T1-84 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Product Selection Plug-on Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Switching duty rated. 3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits. 4 For use as a branch circuit breaker in 400 and 600 ampere panels only. 5 System series rating of 65 kAIC upstream when used in series with 22 kAIC BRHX breakers. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Single-Pole 120/240 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces 10 per Shelf Carton 5 per Shelf Carton 10 kAIC 22 kAIC 10 kAIC 22 kAIC 22 kAIC 42 kAIC 65 kAIC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 5 Catalog Number Catalog Number 10 #14–4 BR110—BR210———— 15 #14–4 BR115 12 BRH115 BR215 3 BRH215 — — — 20 #14–4 BR120 12 BRH120 BR220 3 BRH220 — — — 25 #14–4 BR125 BRH125 BR225 3 BRH225 — — — 30 #14–4 BR130 BRH130 BR230 3 BRH230 — — — 35 #14–4 BR135 BRH135 BR235 3 BRH235 — — — 40 #14–4 BR140 BRH140 BR240 3 BRH240 3 ——— 45 #14–4 — BRH145 BR245 3 BRH245 — — — 50 #14–4 BR150 BRH150 BR250 3 BRH250 3 ——— 55 #14–3 BR150 BRH155 BR255 BRH255 — — — 60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHX260 BRHH260 BRX260 70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHX270 BRHH270 BRX270 80 #8–1/0 — — BR280 BRH280 BRHX280 BRHH280 BRX280 90 #8–1/0 — — BR290 BRH290 BRHX290 BRHH290 BRX290 100 #8–1/0 — — BR2100 BRH2100 BRHX2100 BRHH2100 BRX2100 110 #8–1/0 — — BR2110 BRH2110 BRHX2110 BRHH2110 BRX2110 125 #4–2/0 — — BR2125 BRH2125 BRHX2125 BRHH2125 BRX2125 150 #4–2/0 — — BR2150 4 ———— BR120 BR215 BR320 BRH2100 BRX2125 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC Plug-on, Dual Function Arc Fault / Ground Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac Type BR, 1-Inch (25.4 mm) Dual Function Type AFCI Circuit Breakers 23 Plug-on Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac Type BR, 1-Inch (25.4 mm) Wide Combination Type AFCI Circuit Breakers Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Breaker qualifies as combination arc fault, per UL 1699. 3 Breaker qualifies as personnel protection ground fault, (5 mA) per UL 943. 4 Clamshell packaging available with CS modification code on the end of catalog number. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. See Volume 4 for bolt-on AF/GF breakers; QB1015AFGF. QB1020AFGF, QBH1015AFGF and QBH1020AFGF. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Three-Pole 240 Vac Common Trip Requires Three 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 10 kAIC 22 kAIC Catalog Number Catalog Number 10 #14–4 BR310 — 15 #14–4 BR315 1 BRH315 20 #14–4 BR320 1 BRH320 25 #14–4 BR325 BRH325 30 #14–4 BR330 BRH330 35 #14–4 BR335 BRH335 40 #14–4 BR340 BRH340 45 #14–4 BR345 BRH345 50 #14–4 BR350 BRH350 55 #14–3 BR355 BRH355 60 #4–1/0 BR360 BRH360 70 #4–1/0 BR370 BRH370 80 #4–1/0 BR380 BRH380 90 #4–1/0 BR390 BRH390 100 #4–1/0 BR3100 BRH3100 Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14–4 Dual Function AFCI/GFCI Yes BRN115DF BRP115DF Single-pole, 10 kAIC 20 #14–4 Dual Function AFCI/GFCI Yes BRN120DF BRP120DF Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14-4 Combination AFCI Yes BRN115AF 4 BRP115AF 4 20 #14-4 Combination AFCI Yes BRN120AF 4 BRP120AF 4 Two-pole, 10 kAIC 15 — Combination AFCI —BRL215CAF — 20 — Combination AFCI —BRL220CAF — BR Breakers BRLAFGF115 BRCAF115 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-83 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Circuit Breakers Contents Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-46 BR Plug-on Neutral Loadcenters . . . . . . . . . . .V1-T1-58 Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-61 Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-62 Type BR Renovation Loadcenter . . . . . . . . . . . .V1-T1-63 BR Loadcenter Options and Accessories Type BR Retrofit Interior Kits . . . . . . . . . . . . . .V1-T1-64 Type BR Mechanical Interlock Kits . . . . . . . . . .V1-T1-68 BR Circuit Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . .V1-T1-84 Options and Accessories. . . . . . . . . . . . . . . . . .V1-T1-91 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-93 BR Circuit Breakers Product Description Plug-on Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in the 2005, 2008, and 2011 National Electrical Code. Plug-on Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A combination type arc fault circuit interrupter is a device that includes all of the protection offered by the branch feeder AFCI (mitigation of high current arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Plug-on Ground Fault Circuit Breakers, Type GFTCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac Ground Fault Application Notes Single-pole GFTCBs are designed for use in two- wire, 120 Vac circuits. See Page V1-T1-93 for a typical wiring configuration. Two-pole GFTCBs are designed for use in three- wire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. Page V1-T1-93 shows typical wiring configurations for a 120/240 Vac multiwire circuits, and a 240 Vac, two- wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. The figures are shown with a 120/240 Vac, single-phase, three-wire power source, but are also applicable to a 120/208 Vac, three-phase, four-wire power supply. For all figures, the electrical operation of the GFTCB is not affected by the equipment ground. Non-CTL Plug-on Replacement —Circuit Breakers, Type BRD— 10 kAIC, 120/240 Vac Non-CTL 10 kAIC for Replacement Purposes Only For replacement in enclosures manufactured prior to 1968 with unnotched stabs. Circuit breakers do not have rejection tab. Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC Plug-on, Dual Function Arc Fault / Ground Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac Type BR, 1-Inch (25.4 mm) Dual Function Type AFCI Circuit Breakers 23 Plug-on Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac Type BR, 1-Inch (25.4 mm) Wide Combination Type AFCI Circuit Breakers Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Breaker qualifies as combination arc fault, per UL 1699. 3 Breaker qualifies as personnel protection ground fault, (5 mA) per UL 943. 4 Clamshell packaging available with CS modification code on the end of catalog number. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. See Volume 4 for bolt-on AF/GF breakers; QB1015AFGF. QB1020AFGF, QBH1015AFGF and QBH1020AFGF. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Three-Pole 240 Vac Common Trip Requires Three 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 10 kAIC 22 kAIC Catalog Number Catalog Number 10 #14–4 BR310 — 15 #14–4 BR315 1 BRH315 20 #14–4 BR320 1 BRH320 25 #14–4 BR325 BRH325 30 #14–4 BR330 BRH330 35 #14–4 BR335 BRH335 40 #14–4 BR340 BRH340 45 #14–4 BR345 BRH345 50 #14–4 BR350 BRH350 55 #14–3 BR355 BRH355 60 #4–1/0 BR360 BRH360 70 #4–1/0 BR370 BRH370 80 #4–1/0 BR380 BRH380 90 #4–1/0 BR390 BRH390 100 #4–1/0 BR3100 BRH3100 Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14–4 Dual Function AFCI/GFCI Yes BRN115DF BRP115DF Single-pole, 10 kAIC 20 #14–4 Dual Function AFCI/GFCI Yes BRN120DF BRP120DF Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14-4 Combination AFCI Yes BRN115AF 4 BRP115AF 4 20 #14-4 Combination AFCI Yes BRN120AF 4 BRP120AF 4 Two-pole, 10 kAIC 15 — Combination AFCI —BRL215CAF — 20 — Combination AFCI —BRL220CAF — BR Breakers BRLAFGF115 BRCAF115 Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-83 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Circuit Breakers Contents Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-46 BR Plug-on Neutral Loadcenters . . . . . . . . . . .V1-T1-58 Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-61 Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-62 Type BR Renovation Loadcenter . . . . . . . . . . . .V1-T1-63 BR Loadcenter Options and Accessories Type BR Retrofit Interior Kits . . . . . . . . . . . . . .V1-T1-64 Type BR Mechanical Interlock Kits . . . . . . . . . .V1-T1-68 BR Circuit Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . .V1-T1-84 Options and Accessories. . . . . . . . . . . . . . . . . .V1-T1-91 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .V1-T1-93 BR Circuit Breakers Product Description Plug-on Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in the 2005, 2008, and 2011 National Electrical Code. Plug-on Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A combination type arc fault circuit interrupter is a device that includes all of the protection offered by the branch feeder AFCI (mitigation of high current arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Plug-on Ground Fault Circuit Breakers, Type GFTCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac Ground Fault Application Notes Single-pole GFTCBs are designed for use in two- wire, 120 Vac circuits. See Page V1-T1-93 for a typical wiring configuration. Two-pole GFTCBs are designed for use in three- wire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. Page V1-T1-93 shows typical wiring configurations for a 120/240 Vac multiwire circuits, and a 240 Vac, two- wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. The figures are shown with a 120/240 Vac, single-phase, three-wire power source, but are also applicable to a 120/208 Vac, three-phase, four-wire power supply. For all figures, the electrical operation of the GFTCB is not affected by the equipment ground. Non-CTL Plug-on Replacement —Circuit Breakers, Type BRD— 10 kAIC, 120/240 Vac Non-CTL 10 kAIC for Replacement Purposes Only For replacement in enclosures manufactured prior to 1968 with unnotched stabs. Circuit breakers do not have rejection tab. Volume 1—Residential and Light Commercial CA08100002E—November 2018 www.eaton.com V1-T1-85 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC Plug-on, Dual Function Arc Fault / Ground Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac Type BR, 1-Inch (25.4 mm) Dual Function Type AFCI Circuit Breakers 23 Plug-on Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac Type BR, 1-Inch (25.4 mm) Wide Combination Type AFCI Circuit Breakers Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Breaker qualifies as combination arc fault, per UL 1699. 3 Breaker qualifies as personnel protection ground fault, (5 mA) per UL 943. 4 Clamshell packaging available with CS modification code on the end of catalog number. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. See Volume 4 for bolt-on AF/GF breakers; QB1015AFGF. QB1020AFGF, QBH1015AFGF and QBH1020AFGF. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Three-Pole 240 Vac Common Trip Requires Three 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 10 kAIC 22 kAIC Catalog Number Catalog Number 10 #14–4 BR310 — 15 #14–4 BR315 1 BRH315 20 #14–4 BR320 1 BRH320 25 #14–4 BR325 BRH325 30 #14–4 BR330 BRH330 35 #14–4 BR335 BRH335 40 #14–4 BR340 BRH340 45 #14–4 BR345 BRH345 50 #14–4 BR350 BRH350 55 #14–3 BR355 BRH355 60 #4–1/0 BR360 BRH360 70 #4–1/0 BR370 BRH370 80 #4–1/0 BR380 BRH380 90 #4–1/0 BR390 BRH390 100 #4–1/0 BR3100 BRH3100 Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14–4 Dual Function AFCI/GFCI Yes BRN115DF BRP115DF Single-pole, 10 kAIC 20 #14–4 Dual Function AFCI/GFCI Yes BRN120DF BRP120DF Poles Ampere Rating Wire Size Breaker Type LED Diagnostics Included Pigtail Catalog Number Plug-on Neutral Catalog Number Single-pole, 10 kAIC 15 #14-4 Combination AFCI Yes BRN115AF 4 BRP115AF 4 20 #14-4 Combination AFCI Yes BRN120AF 4 BRP120AF 4 Two-pole, 10 kAIC 15 — Combination AFCI —BRL215CAF — 20 — Combination AFCI —BRL220CAF — BR Breakers BRLAFGF115 BRCAF115