Loading...
HomeMy WebLinkAbout15760-01-0 - Berko Electric Wall & Unit heaters (2) - AZT. . . . . . . . . . . . . . . . . . . . . . . . . . . . D/E/F Services Group, LTD 1171 Voluntown Road Griswold, CT 06351 Phone: (860) 376-4896 Fax: (860) 376-1213 Submittal Transmittal TO: The Maggiore Companies 13 Wheeling Ave. Worburn, MA 01801 Date: 1/21/2020 Project # F29166 - F29166 Oxoboxo Submittal # 17.1 ATTN: Gifford Perry RE: (Berko) Electric Wall & Unit Heaters We are sending you the following:  Attached  Under Separate Cover Via:  1st Class Mail  Overnight  Facsimile  Pick-Up/Hand Deliver Copies Spec No. Description 1 DWG #M2.2 MSK M2.3 12/31/2019 (Berko) Electric Wall & Unit Heaters Remarks: Please see the revised submittal as per Addendum #8 dated 12/31/2019 for review and approval. Received By: _________________________________ Date: ________________________ Signed: _______________________________ Title: _________________________________ Copy to: ___________________  Recipient’s Copy  Sign & Return  File Copy HEATER AIR FLOWCONTROL MOTOR NO. OF TAG QTY. CATALOG NUMBER KW VOLTS Ø AMPS CKT. VOLTS VOLTS CFM F* RISE STAGES HUHAA SERIES - HORIZONTAL / VERTICAL UNIT HEATERSSUBMITTAL SHEET HUHAA SERIES HORIZONTAL / VERTICAL UNIT HEATER CAPACITIES 3KW through 50KW 208, 240, 277, 480V 1Ø or 3Ø (Voltage & Phase varies with model) See Selection Chart 470 Beauty Spot Rd. E, Bennettsville, SC 29512 TAG QTY.CAT. NO.DESCRIPTION ACCESSORIES AND CONTROLS ZSS-BHUHA www.berkomep.com05-17 SUBMITTED BY:DATE APPROVED BY:DATE DIMENSIONSHUHAA SERIESNOTE: 1.All standard units are supplied with a low voltage control transformer and contactor (24V) except HUHAA-3 & 5 Kw, 208, 240, & 277 volt models. Low voltage control on these units is available on made-to-order. All units are also available on special order 120 volt control; internal with transformer or external without transformer. 2.On dual voltage units, CFM, FPM, and RPM are shown at higher voltage. 3.On dual phase units, maximum amp draw is listed for respective voltage. 4.25 thru 50 Kw models have two speed motors and dual CFM ratings. 5A.Standard 5B.Optional-made to order-amp load unbalanced on 3 phase. 5C.Optional-made to order-amp load balanced on 3 phase. ** Must use 2-stage thermostat on 3Ø operation. HEATER HEIGHT WIDTH DEPTH 3 & 5 16''14'' 8-1/2'' 7.5 & 10 21-3/4'' 19'' 8-1/2'' 15 & 20 21-3/4'' 19'' 13-3/4'' 25 & 30 30'' 26-5/8'' 13-3/4'' 40 & 50 30'' 26-5/8'' 18-1/8'' MOUNTING LIMITATIONS Unit heaters should not be used in potentially explosive atmospheres. The finish is not intended for direct salt spray exposure in marine applications or the highly corrosive atmospheres of swimming pools, chemical storage bins, etc. Do not install unit heaters above recommended maximum mounting height. Obstructions must not block unit heater air inlet or discharge. Heaters must be mounted at least 7' above the floor to prevent accidental contact with the heating element or fan blade which could cause injury. STD.HORIZ. CATALOG 2-STAGE CONTROL Air Delivery ^T Motor AIR SHIP. NUMBER VOLTS KW AMPS PH ELEM. VOLTS CFM FPM (F) RPM HP THROW WT) HUHAA320 208 3 14.5 1 NA 208 350 800 27 1600 1/100 12 24 HUHAA520 208 5 24 1-3 5A 208 350 800 45 1600 1/100 12 24 HUHAA720 208 7.5 36 1-3 5B 24 650 970 37 1600 1/30 18 36 HUHAA1020 208 10 48 1-3 5B 24 650 970 49 1600 1/30 18 36 HUHAA1520 208 15 72 1-3 5A 24 910 1640 52 1530 1/20 35 56 HUHAA2020 208 20 56 3 5A 24 1320 2060 48 1500 1/10 41 63 HUHAA3020 208 30 84 3 5A 24 2100/1800 2100/2030 45/53 1600/1375 1/4 50 91 HUHAA5020 208 50 139 3 5A 24 3000/2600 3260/2900 53/61 1525/1420 1/2 60 125 HUHAA324 208/240 2.2/3.0 11.0/12.5 1 NA 208/240 350 800 27 1600 1/100 12 24 HUHAA524 208/240 3.7/5.0 18.0/21.0 1-3 5A 208/240 350 800 45 1600 1/100 12 24 HUHAA724 208/240 5.6/7.5 27.0/31.3 1-3 5B 24 650 970 37 1600 1/30 18 36 HUHAA1024 208/240 7.5/10.0 36.0/42.0 1-3 5B 24 650 970 49 1600 1/30 18 36 HUHAA1524 208/240 11.2/15.0 31.3/36.1 3 5C 24 910 1640 52 1530 1/20 35 56 HUHAA2024 208/240 15.0/20.0 41.2/48 3 5C 24 1320 2060 48 1500 1/10 41 33 HUHAA2524 208/240 18.7/25.0 52.0/60.0 3 5A 24 2100/1800 2100/2030 38/44 1600/1375 1/4 50 91 HUHAA3024 208/240 22.5/30.0 63.0/72.3 3 5A 24 2100/1800 2100/2030 45/53 1600/1375 1/4 50 91 HUHAA4024 208/240 30.0/40.0 83.4/96.4 3 5A 24 3000/2600 3260/2900 42/49 1525/1420 1/2 60 125 HUHAA5024 208/240 37.5/50.0 104.2/120.0 3 5A 24 3000/2600 3260/2900 53/61 1525/1420 1/2 60 125 HUHAA327 277 3 11 1 NA 277 350 800 27 1600 1/100 12 24 HUHAA527 277 5 18 1 NA 277 350 800 45 1600 1/100 12 24 HUHAA727 277 7.5 27 1 5B 24 650 970 37 1600 1/30 18 36 HUHAA1027 277 10 36 1 5B 24 650 970 49 1600 1/30 18 36 HUHAA348 480 3 3.6 3 NA 24 350 800 27 1600 1/100 12 24 HUHAA548 480 563NA 24 350 800 45 1600 1/100 12 24 HUHAA748 480 7.5 935B 24 650 970 37 1600 1/30 18 36 HUHAA1048 480 10 12 3 5B 24 650 970 49 1600 1/30 18 36 HUHAA1548 480 15 18 3 5C 24 910 1640 52 1530 1/20 35 56 HUHAA2048 480 20 24 3 5C 24 1320 2060 48 1500 1/10 41 63 HUHAA2548 480 25 30 3 5C 24 2100/1800 2100/2030 38/44 1600/1375 1/4 50 91 HUHAA3048 480 30 36 3 5C 24 2100/1800 2100/2030 45/53 1600/1375 1/4 50 91 HUHAA4048 480 40 48 3 5A 24 3000/2600 3260/2900 42/49 1525/1420 1/2 60 125 HUHAA5048 480 50 60.2 3 5A 24 3000/2600 3260/2900 53/61 1525/1420 1/2 60 125 W H D OPTIONAL FACTORY INSTALLED CONTROLS & ACCESSORIES (Factory Installed Only - Not to be Field Installed) 3 & 5 KW Heaters with 208, 208/240 or 277 Volt Supply • Control Transformer (120 or 24 Volt Sec.) • Power Contactor (120 or 24 Volt Holding Coil) Optional 120 Volt control • 3 & 5 KW with 480 Volt supply and 7.5 KW thru 50 KW. Two Stage Element Control (See Note 5 Page 2) Manual Reset Bird Screen (Outlet Mesh) OPTIONAL FIELD INSTALLED ELECTRICAL CONTROLS CAT. NO.ACCESSORY ELECTRICAL RATING USE WITH UHMT1 Single Pole Internal Thermostat - Temp. 25A @ 120, 240VAC Res. Range: 40F - 85F 22A @ 277VAC Res. All HUHAA Series Heaters (except 5 KW, 208V - 3PH, 208/240V - 3PH, 277V) UHMT2 Two-Stage Internal Thermostat - Temp. 22A @ 120, 240VAC Res.5 KW, 208 volt 3 ph & 208/240 volt 3 ph, Range: 40F - 85F 22A @ 277VAC Res 125V, 208 volt:15, 20, 30 & 50 KW, A: Pilot Duty 208/240 volt: 25, 30, 40 & 50 KW, 480 volt: 40 &* 50 KW heaters. HUHAAFS Internal Summer Fan Switch 6A, 600VAC Res 2 Hp - 250, All HUHAA Series Heaters 480, 600VAC HUHAARFS1 Remote Summer Fan Switch 2 HP, 250-480VAC All HUHAA Series Heaters (Line Voltage) HUHAARFS2 Remote Summer Fan Switch with Relay 6 AFL, 35 ALR, 250VAC, 60Hz All HUHAA Series Heaters (except 3 & 5 (24V Coil-Single Pole Normally Open) 3 AFL, 18 ALR, 480VAC, 60Hz KW & 208, 208/240 & 277 volt units, unless optional control transformer is supplied) HUHAAHRT Heat Recovery Thermostat with Relay 6 AFL, 35 ALR, 250VAC, 60Hz All HUHAA Series Heaters (except 3 & 5 (24V Coil-Single Pole Normally Open) 3 AFL, 18 ALR, 480VAC, 60Hz KW & 208, 208/240 & 277 volt units, unless Hi - 120F, Low - 60F optional control transformer is supplied) HUHAADS25 Power Disconnect Switch (3 Pole)30A @ 600VAC, Res HUHAA348, HUHAA548, HUHAA748, HUHAA327, HUHAA1048, HUHAA324, HUHAA320, HUHAA527, HUHAA1548, HUHAA524 HUHAADS60 Power Disconnect Switch (3 Pole) 63A @ 600VAC, Res.HUHAA520, HUHAA2048, HUHAA727, HUHAA2548, HUHAA724, HUHAA720, HUHAA1027, HUHAA1524, HUHAA3048, HUHAA1024, HUHAA1020, HUHAA2024, HUHAA4048, HUHAA2020, HUHAA2524, HUHAA5048 OPTIONAL FIELD INSTALLED MECHANICAL CONTROLS HUHAA SERIES- HORIZONTAL / VERTICAL UNIT HEATERSNOTE: Any field installed options assembled in the factory require added surcharge. N 1-1/2 DIM 3-20KW 25-50KW A 7-1/4” 9-7/16” B 9-1/2” 14-3/8” C 7-1/4” 12-1/8” D 1-15/16” 2-1/16” E 2-1/4” 3” L 20-1/2” 28-5/16” N 3-1/4” 4-1/2” UNIVERSAL WALL & CEILING CEILING MOUNTING BRACKET MOUNTING BRACKET CATALOG NO.CATALOG NO. USED ON HEATER KW B10 CMB10 3.5, 7.5, & 10 B20 CMB20 15 & 20 B30 CMB30 25 & 30 B50 CMB50 40 & 50 AA BB HEATERBACK 5/16" BOLTS,LOCKWASHERSAND NUTS(4 LOCATIONS) BRACKETATTACHMENT BOLT (4 LOCATIONS) CATALOG NO.KW AB VDMB5 3 - 5 KW 6” (152mm) 6 1/8” (156mm) VDMB20 7.5 - 20 KW 8 7/8” (225mm) 6 1/8” (156mm) VDMB50 25 - 50 KW 12 1/2” (318 mm) 121/8” (308mm) HUHAA SERIES470 Beauty Spot Rd. E, Bennettsville, SC 29512 ARCHITECT'S AND ENGINEER'S SPECIFICATIONS* Furnish and install type HUHAA horizontal / vertical unit heaters as manufactured by Berko, A Marley Engineered Products Brand, Bennettsville, SC with heating and air delivery capacities as shown on the heating schedule. The cabinet shall be made of 18 gauge die formed furniture grade steel. Individual adjustable louvers with 30 degrees downward stops shall be furnished to provide desired control of discharge air. All metal surfaces of the enclosure shall be phosphate coated to resist corrosion and finished in a durable polyester powder coat finish. Mounting brackets designed for either ceiling or wall swivel mounting shall be furnished as shown on the heating schedule. Heaters shall be of the draw-through air flow design to eliminate the element hot spots and extend design life. Fans shall be aluminum, directly connected to fan motor, and designed specifically for unit heater application. Low voltage control 24 volt transformers shall be standard on models 7.5 KW and greater (Optional 120V), to allow safer more precise temperature control. Individual optional field installable control kits shall be available for all models. All controls shall have pig tails and spade terminals for ease of wiring to centrally located terminal board. All heaters of 63 amperes or less shall be provided with power disconnect switches (field installed kits or factory installed). All heaters shall be UL Listed and meet the requirements of the National Electrical Code. For safety, the electric heating bank shall consist of metal sheath heating elements. The elements shall consist of 80/20 Nichrome wire encased in refractory material (MGO) and have a copper clad steel sheath for strength and corrosion resistance, and aluminum fins for faster heat transfer. Automatic reset thermal overheat protection shall be of the linear capillary type wired for instantaneous de-energizing in case of the thermal overload. Heating bank to have protective air inlet louvers. All heaters drawing in excess of 48 amperes shall be provided with factory installed subdivided and fused circuits of 48 amps or less. Motors shall be totally enclosed, designed for continuous heavy-duty all-angle operation and equipped with built-in thermal overload protection, with stainless steel louvers. Motors used on 25 thru 50 KW models shall be rated for two speed operation. * Berko reserves the right to change specifications without prior notice. DIFFUSER HEATER KW MAX A MNT. HT. DIM NONE 3 & 5 9 18 NONE 7.5 & 10 14 26 NONE 15 20 35 NONE 20 23 40 NONE 25 23 63 NONE 30 20 55 NONE 40 28 70 NONE 50 25 63 DIFFUSER USED ON MAX.AB CAT. NO. HEATER KW MNT. HT. DIM DIM HUHAALDS 3 & 5 9 25 12 HUHAALDM 7.5 & 10 14 39 19 HUHAALDM 15 18 50 25 HUHAALDM 20 20 56 28 HUHAALDL 25 23 68 32 HUHAALDL 30 20 72 36 HUHAALDL 40 24 88 44 HUHAALDL 50 22 80 40 DIFFUSER PATTERN AND AREA LOUVER DIFFUSER NO DIFFUSER A A B PRODUCT SUBMITTAL SHEET 470 Beauty Spot Road East Bennettsville, South Carolina 29512 www.marleymep.com SRA SERIES FAN-FORCED WALL HEATERS Job Name: _________________________________________________________________ Location: __________________________________________________________________ Architect: __________________________________________________________________ Engineer: __________________________________________________________________ Contractor: ________________________________________________________________ Submitted By: ______________________________________________________________ Date: _____________________________________________________________________ Item QTY Catalog Tag Watts Volts PH AMPS Weight Number Submitted By: Date: Approved By: Date: ZSS-BSRAO | 9-2015 Item QTY Part Tag Number ACCESSORIES Capacities 500, 562, 750, 900, 1000, 1125, 1500, 1800 or 2000 Watts 120, 208, 240 or 277V @ 1Ø Only Thermostat Range: 40° - 85° F Air Movement: 65 CFM ARCHITECT’S AND ENGINEER’S SPECIFICATIONS* The heating equipment shall include an electric automatic fan forced air heater suitable for small area heating, as manufactured by Berko®, a Marley Engineered Products® Brand, Bennettsville, SC. The heater shall be designed for wall mounting, recess or surface. Heaters shall be cETLus listed. BACK BOX: The back box shall be designed as a recessed rough-in box in either masonry or frame installations and is also used when surface mounting frames are used in surface mounting installations. The back box shall be heavy gauge galvanized steel and shall contain knockouts through which power leads enter. INNER FRAME ASSEMBLY: The heater assembly, which fits into the back box, shall consist of a heavy gauge steel fan panel to which all of the operational parts of the heater are mounted. The inner frame assembly shall be completely pre- wired. HEATING ELEMENT: The heating element shall be of the non-glowing design consisting of an 80/20 nickel-chromium resistance wire enclosed in a steel sheath to which plate fins are copper brazed. The element shall cover the entire air discharge area to ensure uniform heating of all discharged air. It shall be warrantied for 5 years. ON/OFF SWITCH: A double-pole, single throw on/off switch shall be mounted on the back box for positive disconnect of power supply. It will be completely concealed behind the front cover. MOTOR AND CONTROLS: The fan motor shall be impedance protected, permanently lubricated. Fan control shall be of the bi-metallic, snap-action type and shall activate fan after heating element reaches operating temperature, and continue to operate the fan after the thermostat is satisfied and until all heated air has been discharged. The thermostat shall be single-pole type on all models. Thermal cutout shall be self- hold (manual-reset) type designed to shut off heat in the event of overheating. The fan shall be four-bladed aluminum. A back- up (End of Life) thermal fuse shall be provided for additional safety. SURFACE MOUNTING FRAME: The surface mounting frame shall be of heavy gauge steel designed to mount around the back box for a finished surface installation. Slot knock outs shall be provided for power supply conduit. FRONT COVER: The louvered front cover shall be of heavy gauge steel with a powder paint finish. A plug button will be provided to replace the thermostat knob and render the unit tamper-resistant. FINISH: All sheet metal parts, except the galvanized steel back box, shall be phosphatized, then completely painted by a powder paint process. *In the interest of continual improvements in product and performance, Marley Engineered Products reserves the right to change specifications without notice. SRA1012DSF 120 8.4/4.2 1000/500 3413/1706 14AWG SRA1512DSF 120 12.5/6.3 1500/750 5120/2560 12AWG SRA1812DSF 120 15.0/7.5 1800/900 6143/3072 12AWG SRA2024DSF 240 8.4/4.2 2000/1000 6826/3413 14AWG 208 7.3/3.6 1500/750 5120/2560 14AWG SRA2027DSF 277 7.3/3.6 2000/1000 6826/3413 14AWG 240 6.3/3.2 1500/750 5120/2560 14AWG SRA1527DSF 277 5.5/2.75 1500/750 5120/2560 14AWG 240 4.7/2.4 1125/562 3840/1920 14AWG SRA2020DSF 208 9.6/4.8 2000/1000 6826/3413 14AWG SRASM Surface Mounting Frame (Accessory) Order Separately 12-1/2” (318mm)H X 10-3/8” (264mm)W X 4” (102mm) - Northern White SRAS1 1” (25mm) Recess Mounting Frame (Accessory) Order Separately - Northern White SRAS2 2” (50mm) Recess Mounting Frame (Accessory) Order Separately - Northern White SRAFCTP Tamper-resistant front cover - Northern White Catalog Number Volts Amps Watts BTU/HR Wire Size Accessories ZSS-BSRAO | 9-2015