Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14210-01-0 - elevator shop drawings oxoboxo lofts - reviewed by PBA and Aztech - AN
MAGGIORE CONSTRUCTION CORP. 13 Wheeling Avenue, Woburn, MA 01801 Phone 781.935.6100 FAX 781.933.8044 SUBMITTAL ACTION SHEET Oxoboxo Lofts 40 Pink Row Uncasville, CT General Contractor:Architect: Maggiore Construction Corp.Paul B Bailey Architects 13 Wheeling Ave.110 Audobon Street Woburn, MA 01801 New Haven, CT 06510 Job No.: 1214 Job No.: 16-063 Prepared By:Maggiore Construction Corp. Form of Submittal: Samples Cut Sheets Schedule Shop Drawings Other Description:Elevator shopdrawings for Building B Manufacturer:Kone Elevator Other/Notes:Review shopdrawings and clarrify Kone Elevator list of questions on their letter dated 8-13-19. Elevator for Building F waiting for decision if it's going to be in or not ! Received By MCC:8/13/2019 Received By Owner: 8/14/2019 Reviewed:Comments: Approved Approved as Noted Rejected Revise and Re-submit Compliance Equal Submitted For Approval By: Gifford Perry - Senior Project Manager Approved By: Date:8/14/2019 Date: August 13, 2019 KONE Inc. 60 Commerce Drive 3rd Floor Trumbull, CT 06611 Cell 860-883-2675 www.kone.com annamarie.milano@kone.com Gifford Perry Maggiore Construction Company 13 Wheeling Ave Woburn, MA 01801 Re: Oxoboxo Lofts – Uncasville, CT Dear Gifford, This letter, once completed and returned with KONE’s submittal package, shall serve as your formal request for a delivery date of the equipment. KONE must have this letter completed prior to releasing the elevator into fabrication. No equipment will be released without an executed contract. Equipment Description: 3500 lb. EcoSpace passenger elevator Delivery requested week of: If the jobsite requirements are not complete (see attached list) 2 weeks prior to the requested delivery date, KONE will not be able to release the material from our logistics facility. If the jobsite requirements are not complete, the material will be held at our logistics facility and it will be your responsibility for the additional storage costs ($50.00/day/elevator). Additionally, if you are not ready on the requested delivery date KONE may not be able to begin the installation for up to an additional 2 - 5 weeks. Any labor associated with relocation of material (once on-site) is not included in this proposal. I appreciate your careful consideration to this very critical coordination piece. I ask that you please sign in the space provided below signifying your official request for the above ship dates. Should you have any questions, comments, or concerns, please feel free to contact me. Very truly yours, Anna Marie Milano Sales Executive KONE Inc. Please sign and return with approvals to confirm delivery date. Received and Accepted By: Name / Title Signature / Date To ensure a safe and efficient installation of the elevator(s), the following jobsite requirements must be completed prior to the delivery and installation of the elevator equipment: ▪ Adequate access for delivery of the elevator material. Clean and dry storage space of no less than 10' x 20' (per elevator) adjacent to the hoistway, preferably at the main entrance level. ▪ The hoistway(s) must be plumb within –0" +2" according to the approved KONE layout drawings. ▪ The hoistway(s), pit(s) and control room(s) must be clean, dry and constructed per the KONE approved layout drawings. Rear and side walls must be completed (side walls only for front/rear application) at the time the installation begins. The entire front wall must be left out during the installation of the elevator(s) (rear wall must also be left open on rear opening applications). The bottom landing must be left open to place the equipment in the hoistway. ▪ Adequate guide rail supports must be in place. Please refer to the KONE elevator layouts for bracket support locations. Any intermediate support required between floors is to be furnished & installed by others. Inserts for CMU walls will be provided by KONE to be installed by others. ▪ Removable, OSHA compliant barricades must be provided around all hoistway openings. Also provide and install full-covering entry protection, made of nylon mesh or reinforced plastic, at all hoistway openings to prevent materials or tooling from falling into the elevator shaft during the installation. ▪ Permanent single and three-phase power (or temporary power with permanent characteristics) must be available in the control room on the first day of our installation. Also, a temp. 220, 30 amp source must be provided by others near the elevator hoistway(s) for our minifor hoist. ▪ A hoist beam (provided by KONE) must be installed by others per the approved KONE layout drawings. The hoist beam must be installed so that it shall be capable of supporting the load requirement noted in our shop drawings. In addition to the hoist beam, KONE will provide a 4”x4” tube to be installed by others in front of the hoist beam for our lifeline attachments. ▪ Applicable work areas must have adequate lighting at landing levels and in hoistway(s). ▪ Finished floor marks, which are visible from the hoistway opening at each landing. KONE, Inc. 60 Commerce Drive Trumbull, CT 06611T Telephone (860) 883-2675 annamarie.milano@kone.com CT License 475406 August 13, 2019 Gifford Perry Maggiore Construction Company 13 Wheeling Ave Woburn, MA 01801 Re: Oxoboxo Lofts Uncasville, CT Dear Gifford, Please find enclosed the following for your immediate review and approval. One (1) Set – Mechanical/Cab/Entrance/Fixture Layouts One (1) ea – Plastic Laminate Brochure One (1) – Power Confirmation Form Please be advised, all information noted herein, including the clouded areas, must be provided or confirmed and returned to KONE for the release and fabrication of the equipment. Please confirm your schedule requirements with KONE Construction Superintendent, Corey Violette @ 860-250-6730, or myself. Dwg. No. M-1979954 (Sheet 1): 1. Confirm 3500 lb. rated capacity. 2. Confirm or provide the clear inside dimensions of the elevator hoistway. Note the minimum dimension must be 8’- 6” W x 6’- 11”D. 3. Confirm left hand door. Dwg. No. M-1979954 (Sheet 2): 1. The clear overhead dimension under the hoist beam (13’- 10”) 2. Confirm that elevator total travel to be 28’- 8”. 3. The pit depth dimension to be 5’-0”. 4. Confirm that the floor designations to be“ B, *1, 2 & 3 and floor heights. 5. Confirm that the Main Elevator Lobby floor designation to be “*1”. 6. The Alternate Fire Service Floor to be B. Dwg. No. M- 1979954 (Sheet 7 & 8): 1. Note the “Work Not Included in Elevator Contract” requirements. KONE, Inc. 60 Commerce Drive Trumbull, CT 06611T Telephone (860) 883-2675 annamarie.milano@kone.com CT License 475406 Dwg. No. C-1979954 (Sheet 9): 1. Ceiling: Stainless Steel #4 Panels with LED Lights – LF - 88 2. Cab Walls: Plastic Laminate ___________ 3. Return Wall & Jamb: Stainless Steel #4 4. Car Door: Stainless Steel #4 5. Cab Height – 8’-0” overall – 7’- 4” inside 6. Car Door Height – 7’-0” Dwg. No. E-1979954 (Sheet 10 - 12 ): 1. The total wall thickness at each floor = ______________ 2. The Entrance Doors/Frames finish - Stainless Steel #4 Fixtures: Hall Stations at each floor All Fixtures shall be Stainless Steel #4 – KSS570 Series Hall Lantern @ floor B, 2 & 3 Combination Hall Lantern & Position Indicator @ floor *1 Select Orientation of Fixtures – Horizontal for Vertical The manufacturing lead time for this equipment is approximately (12) weeks after receipt of approved layouts and executed contract. Please return one (1) copy of each item “Approved or “Approved as Noted to my attention and indicate your required ship date________________________ If you have any questions please do not hesitate to call me. Sincerely, KONE, Inc. Anna Marie Milano Sales Executive Power Confirmation Form WF-MKT-06-007 Rev. 2/12/01 POWER CONFIRMATION KONE Inc. 60 Commerce Drive 3rd Floor Trumbull, CT 06611 Cell: (860) 883-2675 www.kone.com annamarie.milano@kone.com CT License # 00400088 Gifford Perry Maggiore Construction Corp. 13 Wheeling Ave Woburn, MA 01801 Re: Oxoboxo Lofts – Uncasville, CT Date: August 13, 2019 The KONE equipment listed below requires provision of three (3) phase and single phase power wires to the machine room(s) and connection to the terminals of the KONE controller(s) with properly sized, intervening fused disconnect switch(es) conveniently located in the machine room(s). Provision of this electrical service is the Purchaser's responsibility (NOT KONE). The required electrical distribution system is to be designed to accommodate the power characteristics explained below. KONE EQUIPMENT POWER REQUIREMENTS BASED UPON ANTICIPATED POWER SUPPLY OF: 208 VOLTS(AC) 3 PHASE 60 HERTZ KONE CONTRACT NUMBER UNIT DESCRIPTION AND/ HORSEPOWER FULL LOADS AMPERES MAXIMUM START/ACCEL AMPERES RECOMMEND ED FUSE SIZE Hoist Motor/11.9 42 59 60 Special note: In the event the Emergency Power/Generators are to be incorporated in this project, such Generator(s) are to be sized in accordance with this data. This electrical information is most important. Please distribute this data to all parties involved. Sincerely, KONE Inc. APPROVED: Company Name: _________________________ Signed by: _________________________ Date: _________________________ Anna Marie Milano Sales Executive KONE EcoSpace™ MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY 2 KONE EcoSpace The Revolutionary MRL Elevator Concept The secret behind the KONE EcoSpace elevator is the permanent-magnet, gearless KONE EcoDisc® motor. KONE’s Machine Room-Less technology eliminates the need for a machine or control room by attaching the hoisting machine to the guide rail, and placing all control and logic components within the confines of the hoistway. Greater efficiency The revolutionary KONE EcoDisc weighs less than half of a conventional geared traction machine, and has only one moving part. Its efficiency is three times that of a hydraulic power unit and uses 70% less energy – a savings which can represent half or more of the annual cost of the elevator operation. Space savings KONE EcoSpace does not need a separate machine room thanks to the KONE EcoDisc hoisting motor, which is so compact that it can be located in the hoistway. There is no need for a control room as the KONE EcoSpace control and logic components fit inside the wall of the top elevator landing. Simplified installation The whole elevator fits inside the shaft, simplifying the building interface and saving space for more profitable use. This also speeds up the installation process, since no scaffolding or cranage is needed. 3KONE EcoSpace KONE EcoDisc – gearless energy saver KONE took the technological lead in the elevator industry by developing the KONE EcoDisc hoisting machine. With over 440,000 installations worldwide, KONE continues to develop MRL technology while focusing on energy and space efficiency, reliability and excellent ride comfort. The KONE EcoDisc is the core technology for all KONE Eco-efficient™ gearless elevators. It employs a permanent- magnet synchronous motor, frequency control and low-friction gearless construction. Regenerative System The energy consumption of a KONE EcoSpace can be further reduced with the installation of a Regenerative Drive System. ■ This option recovers excess energy from the elevator when the KONE EcoDisc motor acts as a generator ■ This most notably occurs with an empty car traveling UP or a full car traveling DOWN ■ Can recover up to 25% of the total energy used by an elevator ■ Produces clean and safe energy that does not damage the network KONE’s MRL technology has successfully helped projects earn LEED credits in the Energy & Atmosphere and Innovation & Design categories. Product material content KONE EcoSpace is mainly composed of steel and cast iron. The metals, which are about 97% of the elevator material weight, are recyclable. The product does not contain asbestos, paints containing lead or cadmium pigments, condensators containing PCBs or PCTs, ozone layer depleting chemicals such as CFCs, or chlorinated solvents. Mercury is not used in applications other than lighting and batteries. Cadmium stabilizers are not used in plastics. Aluminum 0.5 Cast iron 6.3 Copper 0.9 Stainless steel 0.0 Steel 73.4 Steel (zinc coated) 14.2 Plastics 0.9 Others 0.1 Electronics and electromechanical components 3.6 Material weight % 4 KONE EcoSpace Aesthetic Options for Your New Elevator The KONE EcoSpace elevator offers a wide selection of cabs, entrances and signalization to enhance the look of your building at an affordable price. For KONE, the goal is to create the best possible user experience. A smooth ride and reliable performance ensure the ideal people flow, while the car interior design creates an aesthetically pleasing experience for each passenger. For additional aesthetic interior offerings, reference the KONE Design Collection Catalog. Several ceiling designs are available for KONE EcoSpace elevator cabs. Ceilings Handrails LF-1 Panels Polygal Translucent Frame Brushed Aluminum Lighting T-5 Fluorescent LF-88 Panels Stainless Steel with Satin Finish Lighting Round LED* LF-2 Panels Stainless Steel with Satin Finish Lighting T-5 Fluorescent LF-94 Panels Stainless Steel with Satin Finish Lighting T-5 Fluorescent LF-97 Panels Stainless Steel with Satin Finish Lighting Square LED* LF-98 Panels Stainless Steel with Satin Finish Lighting Rectangular LED* * Six light fixtures for Passenger Shape and nine light fixtures for Service Shape. For additional aesthetic offerings reference the KONE Design Collection Catalog, or visit www.kone.us for the latest job-specific Cab Designer Tool, CAD drawings and specifications. 1.25" Round in Brushed Aluminum, Stainless Steel with Satin finish 2" Round in Stainless Steel with Satin finish 1.5" Flat in Stainless Steel with Satin finish 2" Flat in Stainless Steel with Satin finish 3" Flat in Stainless Steel with Satin finish 4" Flat in Stainless Steel with Satin finish 5KONE EcoSpace Choose from a wide variety of high- quality interior materials. Multiple combinations of wall and ceiling materials are available, allowing you to match virtually any lobby design. Walls Additional aesthetic offerings now available. To reduce our carbon footprint, KONE has begun using QR – or Quick Response – codes, which are an environmentally-friendly alternative to printed materials. Simply scan this QR code with your smartphone and you’ll be taken to the EcoSpace architectural toolbox where you can create job-specific CAD drawings and specifications. Or just type in this shortened URL link – bit.ly/estool. In addition, you can find our products with ARCAT at www.arcat.com. 4757-60* Mystique Moonlight 4798-60* Burnished Ember 4638-60* Monterey Sun 4813-60* Nickel Ev ES2002T** Honeytone Essence 4744-60* Karratha Brush 4746-60* Woolamai 4623-60* Graphite Nebula 4669-60* Natural Tigris WZ1001T** Red Dragon Bamboo Laminate Brands * Wilson Art ** Nevamar Color Finishes 7850-60* Beigewood 10776-60* Kensington Maple 7062-60* Congo Spruce 7919-38* Amber Cherry 7054-60* Wild Cherry 7039-60* Windsor Mahogany 7949-38* Asian Night 7040A-60* Figured Mahogany Wood Finishes Scottish Quad Rigidized Stainless Steel 6258* Satin Brushed Gold 6313* Bronze Stria 6312* Mercury Stria 6262* Satin Brushed Med. Bronze 6261* Satin Brushed Light Bronze 6277* Alumasteel Metal Finishes D487-07* Pearl Silver LS D485-07* Pearl Bisque LS Pearlescent Finishes For additional aesthetic offerings reference the KONE Design Collection Catalog, or visit www.kone.us for the latest job-specific Cab Designer Tool, CAD drawings and specifications. 6 KONE EcoSpace Signalization KONE KSS 570 Signalization enhances the look of your elevator. KSS 140 Vandal Resistant signalization is impact, scratch, burn and splash resistant. Hall Stations KSS 570 Flush Hall Lanterns For additional aesthetic offerings reference the KONE Design Collection Catalog, or visit www.kone.us for the latest job-specific Cab Designer Tool, CAD drawings and specifications. Hall Stations KSS 140 Hall Lanterns Integrated Control Solution FOR KONE ECOSPACE™ Key benefits n With the Integrated Control Solution for KONE EcoSpace, the elevator control is located inside the front wall at the top landing, eliminating the need for a separate control space. n Same proven KONE EcoSpace system and components with over 10,000 installations. n 100% code compliant. n Allows the inspection, maintenance and testing of the full logic control to be performed safely from the top landing, and not from the car top inside the elevator hoistway. n The integrated control logic panel for KONE EcoSpace does not have exposed electrification components over 50 volts. Closed Open The Integrated Control Solution eliminates the need for a separate control space, saving construction time and material costs. This space-efficient solution increases architectural design freedom and allows owners more rentable space. Design n Certified for compliance with CSA B44.1-11 / ASME A17.5-2011 and is allowed per: ASME A17.1-2005s/CSA B44S1-06, NFPA 101-2003, CEC 2009, NFPA 70-2008 or later. All jurisdictions except CA, NYC, MA, WA and Saskatchewan allow for an integrated control solution. n Utilizes the same components as a remote control space configuration, but distributes them within the hoistway and connects them with plug connectors. n The integrated control must be located on the machine side of the top landing front entrance. n Top Landing ICS entrance frame cover is lockable and utilizes Type 1 Security Key Switch (KONE - 1). n A manual brake release is provided and includes a direction and speed module. n Available for new and existing buildings. n Available with speeds up to 200 fpm. n Available with regenerative and non-regenerative drives. n Available for seismic and non-seismic applications. n The top landing wall construction (either block or drywall) must have a minimum finished wall thickness of 8.27". The back of the control cabinet must be faced with two layers of drywall. Build n Eliminates the control space and associated electrical, HVAC and fire protection. n Eliminates job-site coordination and conflict resolution of remote wire runs. n A three-phase fused disconnect is located in the building electrical distribution room and a three-phase non-fused disconnect is mounted in the elevator overhead. No temporary work platforms are required. n All elevator associated wiring such as telephone and heat and smoke sensor wiring are routed to the ICS duct in the overhead and pulled to a junction box at the back of the control cabinet. n Seismic applications require a 10" x 10" seismic switch box mounted in a top landing non-entrance hoistway wall. Maintain n Barricades, similar to those for an integral control space, are required. n On-site service documentation is located on the car top in a crushproof box. n The method of resetting the governor remains the same. n All inspections and tests can and will be performed in accordance with A17.2. There is no change to the current in car, top of car, regular hoistway or control space inspections. The yearly or five-year governor and safety inspection procedures remain the same. For more information go to www.kone.us ©2014 KONE Inc. SF2957 Rev. 0714 U.S. Operations Center One KONE Court Moline, Illinois 61265 1-800-956-KONE (5663) Canadian Operations Centre 6696 Financial Drive, Unit 2 Mississauga, Ontario L5N 7J6 1-905-858-8383 KONE Mexico, S.A. de C.V. Av. Coyoacán 1622 Ed. 1 PB Col. Del Valle Sur México City, D.F. CP 03100 +52.55.1946.0100 For the latest product information and interactive design tools, visit www.kone.us KONE is a registered trademark of KONE Inc. Dedicated to People Flow and EcoSpace are trademarks of KONE Inc. “USGBC” and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Features Integrated Control Solution for KONE EcoSpace KONE EcoSpaceTM Elevator Wall Materials Color Finishes Mystique Moonlight 4757-60* Burnished Chestnut 4796-60* Soft Gold Mesh 4911-38* Nickel Ev 4813-60* Woolamai 4746-60*Graphite Nebula 4623-60* Natural Tigris 4669-60* Red Dragon Bamboo WZ1001T** Metal Finishes Scottish Quad K Satin Brushed Gold 6258* Plex Bronzetone M6486*** Brushed Black Aluminum M4254*** Satin Brushed Med. Bronze 6262* Satin Brushed Light Bronze 6261* Alumasteel 6277* Brushed Stainless Steel Wood Finishes Beigewood 7850-60* Kensington Maple 10776-60* Congo Spruce 7062-60* Amber Cherry 7919-38* Wild Cherry 7054-60* Windsor Mahogany 7039-60* Asian Night 7949-38* Figured Mahogany 7040A-60* Pearlescent Finishes Pearl Silver LS D487-07* Pearl Bisque LS D485-07* Laminate Brands * Wilson Art ** Nevamar ***Formica SF3057Rev 0519This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. Formica is a registered trademark of The Diller Corporation, a subsidiary of Formica Corporation. Wilsonart is a registered trademark of Wilsonart LLC. KONE MonoSpace® and KONE MiniSpace™ are trademarks or registered trademarks of KONE Corporation. Copyright © 2019 KONE Inc.